FAS Track UL Assemblies
Section 1
Standard Wall Assemblies 1� Total Movement
HW-D-0514 � Perpendicular Fluted Deck with Fireproofing
HW-D-0514 � Perpendicular Fluted Deck with Fireproofing and Z-clip
HW-D-0514 � Parallel to Fluted Deck with Fireproofing and Z-clip
HW-D-0515 � Concrete Slab
HW-D-0518 � Perpendicular to Fluted Deck
HW-D-0518 � Perpendicular to Fluted Deck, 3 Hour Rating
HW-D-0524 � Parallel to Flute (FAS Strap)
HW-D-0550 � Gypsum Wallboard Ceiling
HW-D-0551 � Stairwell By-Pass at I-Beam
HW-D-0551 � Centered Directly Under Beam
HW-D-0551 � Off-Center Under Beam
HW-D-0553 � Chase Wall at Pan Deck
HW-D-0554 � Chase Wall at Concrete Slab
HW-D-0556 � Parallel to I-Beam
HW-D-0573 � Perpendicular I-Beam Penetration
HW-D-0596 � Head of Wall System at Stairwell Slab
HW-D-0600 � Cantilever Under Beam � Regular Wall
HW-D-0620 � Parallel Under Pan Deck
Section 2
Standard Wall Assemblies 2� Total Movement
HW-D-0576 � Chase Wall at Concrete Slab
HW-D-0577 � Perpendicular to Fluted Deck
HW-D-0578 � Gypsum Wallboard Ceiling
HW-D-0579 � Centered Directly Under Beam
HW-D-0580 � Chase Wall at Pan Deck
HW-D-0581 � Concrete Slab
HW-D-0582 � Parallel with Fluted Deck
HW-D-0583 � Perpendicular I-Beam Penetration
HW-D-0587 � Parallel with Fluted Deck (FAS Strap)
HW-D-0601 � Parallel to I-Beam � Regular Wall and Z-Bar
Section 3
Shaft Wall Assemblies 1� Total Movement
HW-D-0557 � Concrete with Shaft-Wall
HW-D-0524 � Shaft Wall Parallel to Flute (FAS Strap)
HW-D-0525 � Fluted Deck Shaft-Wall
HW-D-0525 � Parallel to Fireproofed Fluted Deck Shaft-Wall
HW-D-0525 � Perpendicular to Fireproofed Fluted Deck Shaft-Wall
HW-D-0563 � Shaft-Wall Parallel to Beam
HW-D-0598 � Parallel Cantilever Under Shaft
HW-D-0623 � Perpendicular I-Beam Penetration
HW-D-0622 � Shaft Wall under I-Beam
HW-D-0621 � Shaft Wall Slab By-Pass
Section 4
Shaft Wall Assemblies 2� Total Movement
HW-D-0584 � Shaft-Wall Fluted Deck, 2� Movement
HW-D-0585 � Shaft-Wall at Concrete Slab 2� Movement
HW-D-0586 � Shaft-Wall Parallel to Beam, 2� Movement
HW-D-0599 � Parallel Cantilever Under Shaft-Wall
HW-D-0587 � Shaft-Wall Parallel to Fluted Deck (FAS Strap)
HW-D-0623 � Perpendicular I-Beam Penetration
HW-D-0622 � Shaft Wall under I-Beam
Section 5
FAS Track 500 ½� Total Movement
HW-D-0624 � Standard Wall to Concrete Deck
HW-D-0625 � Shaft Wall to Concrete Deck
Section6
Vertical Wall Assembly
WW-S-0057 �Standard Wall Vertical Wall Tie-in to Concrete Column
WW-S-0061 Shaft Wall Vertical Wall Tie-in to Concrete Column
Section 7
Bottom of Wall
BW-S-0024 � Bottom Track static joint
Section 8
Specification Sheets
Contact Product Manager Don Pilz for any technical support at [email protected] or
(626) 506-3881.
Section 1 STANDARD WALL ASSEMBLIES
1� TOTAL MOVEMENT
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 2 STANDARD WALL ASSEMBLIES
2� TOTAL MOVEMENT
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 3 SHAFT-WALL ASSEMBLIES
1� TOTAL MOVEMENT
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 4 SHAFT-WALL ASSEMBLIES
2� TOTAL MOVEMENT
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 5 FAS-TRACK 500 ASSEMBLIES
1/2� TOTAL MOVEMENT
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 6 VERTICAL WALL ASSEMBLIES
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 7 BOTTOM OF WALL ASSEMBLY
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
Section 8 SPECIFICATION SHEETS
For all technical support, contact Don Pilz at [email protected] or 626-506-3881
The Innovators of Quality Framing and Lath Systems
CEMCO FAS Track Specification Sheet
Patent No. US 7, 617, 643 B2
Track Member Width
Length
Gauge (mils)
2 ½”, 3 5/8”, 4”, 6”, and 8”
10’ 0” 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil)
Drift slots on the web are optional. CEMCO FAS Track is a slotted deflection track that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 and 14 gauges (54 and 68 mils) with a minimum G60 coating complying with ASTM A924. The FAS Track is designed with Blazeseal intumescent fire rated tape on both site of the FAS Track. The FAS Track is listed under Underwriters Laboratories for one and two hour head of wall fire rated wall assemblies.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO.
Corporate Office: 263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street, City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204 Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626 Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO Deep Leg FAS Track Specification
Patent No. US 7, 617, 643 B2 Track Member Width
Length
Gauge (mils)
2 ½”, 3 5/8”, 4”, 6”, and 8”
10’ 0” 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil)
CEMCO Deep Leg FAS Track is a deflection track that offers fire and air(smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 and 14 gauges (54 and 68 mils) with a minimum G60 coating complying with ASTM A924. The Deep Leg FAS Track is designed with Blazeseal intumescent fire rated tape on both site of the Deep Leg FAS Track. The Deep Leg FAS Track is listed under Underwriters Laboratories for one and two hour head of wall fire rated wall assemblies.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office: 263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street, City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204 Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626 Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS SHAFT TRACK Specification
Patent No. US 7, 617, 643 B2
Track Member Width (A)
Length
Gauge (mils)
2 ½”, 4” and 6”
10’ 0” 20 GA (33mil)
Drift slots on the web are optional. Vertical Slots on the Flange are optional for positive attachment. CEMCO FAS SHAFT TRACK is a slotted deflection track that offers fire and air (smoke) protection in shaft wall assemblies. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 gauge (33 mils) with a minimum G40 coating complying with ASTM A924. The FAS SHAFT TRACK is designed with factory applied intumescent fire rated tape on non shaft side of the FAS SHAFT TRACK. The FAS SHAFT TRACK is listed under Underwriters Laboratories for one and two hour head of wall fire rated wall assemblies.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO.
Corporate Office: 263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street, City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204 Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626 Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS Shaft Track DL2 Specification Sheet
Patent No. US 7, 617, 643 B2
Track Member Width
Length
Gauge (mils)
2 ½”, 4”, and 6” 10’ 0” 20 GA (33mil)
Drift slots on the web are optional.
CEMCO FAS Shaft Track DL2 is a deep leg deflection track that offers fire and air (smoke) protection for shaft wall assemblies. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Structural Grade 50 Type H for 50 ksi yield strength steel and Grade 33 Type H 33 ksi yield strength steel with a minimum G40 coating. The FAS Shaft Track DL2 is manufactured with Blazeseal intumescent fire rated tape on the top portion of the leg wrapping the corner onto the back web of the track on one side only. The FAS Shaft Track DL2 is listed under Underwriters Laboratories for one and two hour rated head of wall assemblies.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office: 263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street, City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204 Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626 Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS Track 500 Specification Sheet
Track Member Width
(A)
Length
Gauge
(mils)
(G) 2 ½”, 3 5/8”, 4”, 6”, and 8”
10’ 0” 20, 18, 16, and 14 GA
(33, 43, 54, and 68 mil) Drift slots on the web are optional.
CEMCO FAS Track 500 is a deflection track that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 and 14 gauges (54 and 68 mils) with a minimum G60 coating complying with ASTM A924. The CEMCO FAS Track 500 is designed with a ½” Blazeseal intumescent fire rated tape on both side of the FAS Track 500.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office:
263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street,
City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204
Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626
Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS Shaft Track 500 Specification Sheet
Patent No. US 7, 617, 643 B2
Track Member Width
(A)
Length
Gauge
(mils)
2 ½”, 4”, and 6” 10’ 0” 20 GA
(33mil)
Drift slots on the web are optional.
CEMCO FAS Shaft Track 500 is a deflection track that offers fire and air (smoke) protection for shaft wall assemblies. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Structural Grade 50 Type H for 50 ksi yield strength steel and Grade 33 Type H 33 ksi yield strength steel with a minimum G40 coating. The FAS Shaft Track 500 is manufactured with a ½” Blazeseal intumescent fire rated tape on applied on non shaft side of the FAS Shaft Track 500.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office:
263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street,
City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204
Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626
Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS Track DL 500 Specification Sheet
Track Member Width
(A)
Length
Gauge
(mils)
(G) 2 ½”, 3 5/8”, 4”, 6”, and 8”
10’ 0” 20, 18, 16, and 14 GA
(33, 43, 54, and 68 mil)
Drift slots on the web are optional.
CEMCO FAS Track DL 500 is a deep leg deflection track that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 and 14 gauges (54 and 68 mils) with a minimum G60 coating complying with ASTM A924. The FAS Track DL 500 is manufactured with a ½” Blazeseal intumescent fire rated tape on the top portion of the leg wrapping the corner onto the back web of the track.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office:
263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street,
City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204
Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626
Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627 www.cemcosteel.com
The Innovators of Quality Framing and Lath Systems
CEMCO FAS STRAP Specification
PATENT PENDING
Member Width
Length
Gauge
(mils) 10 ½ ”
10’ 0” 20, 18,16 and 14
(33, 43, 54, and 68)
CEMCO FAS STRAP is a flat strap with 2 strips of ½” intumescent. This strap is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 and 14 gauges (54 and 68 mils) with a minimum G60 coating complying with ASTM A924. The FAS STRAP is listed under Underwriters Laboratories for one and two hour head of wall fire rated wall assemblies.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO. Corporate Office:
263 N. Covina Lane, 1001-A Pittsburg Antioch Hwy, 490 Osage Street,
City of Industry, CA 91744 Pittsburg, CA 94565 Denver, CO 80204
Phone (800) 775-2362 Phone (925) 473-9340 Phone (303) 572-3626
Fax (626) 330-7598 Fax (925) 473-9341 Fax (303) 572-3627
www.cemcosteel.com
FAS TRACK’S ENVIRONMENTAL BENEFITS AND LEED CONTRIBUTIONS
FAS Track™ represents an environmental advancement for interior partition construction. Its resilient intumescent layer of Blaze Seal makes it a one-piece solution to acoustical and ire resistive head assemblies. FAS Track’s partition head assembly eliminates most bridging, elastomeric sealants, mineral wool, and the need to cut drywall to it the lutes of decking. FAS Track reduces scraps and waste and often does not require any sealant to be applied to the head of wall joint. Resources are saved, and indoor air quality is improved.
FAS Track contributes to a number of LEED credits in the 2009 New Construction, Core and Shell, Commercial Interiors, and Schools rating systems.
RESOURCE CONSERVATION: Because even very short pieces of FAS Track are used in construction, very little is wasted. Scraps as small as 16 inches are often retained. The metal portion of smaller scraps can be recycled, once the BlazeSeal is peeled off by hand. For projects with high targets for MR 2 Construction Waste Management, this method of recycling FAS Track scraps will contribute to this credit.
MR CREDIT 4 RECYCLED CONTENT: Like all of CEMCO’s framing products, FAS Track contributes 32.7% recycled content to this credit.
IEQ 3.2 INDOOR AIR QUALITY MANAGEMENT PLAN – BEFORE OCCUPANCY: If the Air Testing option is selected by the project team, FAS Track is a valuable player in achieving this credit. FAS Track eliminates the need for spray-applied smoke seal and elastomeric ire sealant. It also can take the place of acoustical sealant in some assemblies. With no solvents and very low VOC content, FAS Track signiicantly reduces indoor air pollution. The Air Testing option is dificult to achieve, and every bit of indoor pollution that FAS Track eliminates from the project increases the chances of success. IEQ 4.1 LOW-EMITTING MATERIALS – ADHESIVES AND SEALANTS:FAS Track’s intumescent ire-resistive seal is a solid, factory-applied layer, so it is not required to comply with the Adhesives and Sealants VOC limits. Moreover, because BlazeSeal provides all the ire protection required for many partitions, no spray-applied smoke seals or elastomeric ire-resistive sealants are required, so their VOC contributions are eliminated.
IEQ 4.6 LOW-EMITTING MATERIALS – CEILING AND WALL SYSTEMS (LEED FOR SCHOOLS): This credit does not apply to FAS Track. Only the gypsum board and the wall coverings are required to be tested.
IEQ 9 ENHANCED ACOUSTICAL PERFORMANCE (LEED FOR SCHOOLS): FAS Track improves the Sound Transmission Class (STC) of partitions, and can even eliminate the need for acoustical sealant at the head of partitions. Its resilient BlazeSeal layer helps damp sound transmission of partitions around core learning spaces and can help achieve this credit.
For other LEED credit contributions, see HYPERLINK “http://www.cemcosteel.com” www.cemcosteel.com and click “LEED Certiication”.
If you have any questions, concerns, or clariications, please contact our Technical Services Department at (800) 416-2278 or HYPERLINK “http://www.cemcosteel.com” www.cemcosteel.com.
Corporate Headquarters &
Main Manufacturing Facility
263 North Covina Lane
City of Industry, CA 91744
800.775.2362 Phone
626.330.7598 Fax
Northern California
Manufacturing Facility
1001-A Pittsburg Antioch Hwy
Pittsburg, CA 94565
925.473.9340 Phone
925.473.9341 Fax
Denver Colorado
Manufacturing Facility
490 Osage Street
Denver, CO 80204
303.572.3626 Phone
303.572.3627 Fax
Printed on 50% recycled
25% post–consumer waste
8 0 0 . 7 7 5 . 2 3 6 2
WWW.CEMCOSTEEL.COM
CEMCO925-473-9340Customer Servicewww.cemcosteel.com
Marino\Ware219-378-7100Mike Fenbertwww.marinoware.com
Marino\Ware800-504-8199Bill Maynewww.marinoware.com
Marino\Ware800-627-8199Gerry Comptonwww.marinoware.com
CEMCO303-572-3626Customer Servicewww.cemcosteel.com
CEMCO925-473-9340Customer Servicewww.cemcosteel.com
CEMCO925-473-9340Customer Servicewww.cemcosteel.com
CEMCO800-775-2362Customer Servicewww.cemcosteel.com