MANUFACTURERS OF AIR, FIRE AND SMOKE CONTROL PRODUCTS FD-R Series Square to Round Ductwork Transformation Piece Suitable for Circular Fire and Volume Control Dampers PATENT APPLIED FOR 15 transformation pieces Supplied loose Complies with DW144
Transcript
Page 1: FD-R Series - BSB · The fitting of the FD-R transformation piece to the FD-C or FSD-C series damper is considered to have no adverse affects on the damper performance that it is

M A N U FAC T U R E R S O F A I R , F I R E A N D S M O K E C O N T RO L P R O D U C T S

FD-R Series

Square to Round DuctworkTransformation Piece Suitable for Circular Fire and Volume Control Dampers

PATENT APPLIED FOR• 15 transformation pieces

• Supplied loose

• Complies with DW144

Page 2: FD-R Series - BSB · The fitting of the FD-R transformation piece to the FD-C or FSD-C series damper is considered to have no adverse affects on the damper performance that it is

FD-R SeriesSquare to Round Transformation Piece

www.bsb-dampers.co.uk2

Introduction

The transformation FD-R section has been designed to make the FD-C damper and FSD-C damper fully flexible. The square to roundconnection allows the space saving FD-C and FSD-C damper rangeto connect to the most common square/rectangular duct size rangeused where space is at a premium typically within floor voids andabove ceilings without increasing the perimeter dimension of theassembled unit.

The female round connection has been designed to have minimaltolerance once fitted to the damper that will allow a rivet or otheracceptable fixing to make a good connection requiring minimalsealant.

The male quadrilateral connection has been designed to acceptconnecting ductwork that slips onto the transformation section withminimal tolerance to allow a rivet or other acceptable fixing to makea good connection requiring minimal sealant.

Construction

Galvanised 0.7mm steel sheet is used in forming the tapered interfacefrom a round connection at the damper to the quadrilateralconnection at the ductwork.

The formed tapered sections are joined via stitch welding withcorner bracings of the quadrilateral connection welded and sealed.The interaction of the transformation assembled section with theround connection section, are also welded and sealed.

Pressure Loss

The fitting of the FD-R transformation piece to the FD-C or FSD-Cseries damper is considered to have no adverse affects on thedamper performance that it is affixed to. Please refer to the individualdamper brochures for performance details.

Maintenance

FD-R series transformation piece has been designed for inclusionwithin normal dry filtered air systems and is not intended for externalapplications.

Inspection and cleaning should be carried out as part of themaintenance programme.

A B C D E F100 x 100 100 70 30 30 130150 x 100 150 70 30 30 130150 x 150 200 95 30 30 155200 x 100 200 95 30 30 155200 x 150 200 95 30 30 155200 x 200 250 70 30 30 130250 x 100 250 120 30 30 180250 x 150 250 120 30 30 180250 x 200 250 95 30 30 155250 x 250 300 70 30 30 130300 x 100 300 120 30 30 180300 x 150 300 120 30 30 180300 x 200 300 120 30 30 180300 x 250 300 120 30 30 180300 x 300 300 70 30 30 130

Dimensions

Page 3: FD-R Series - BSB · The fitting of the FD-R transformation piece to the FD-C or FSD-C series damper is considered to have no adverse affects on the damper performance that it is

FD-R SeriesSquare to Round Transformation Piece

3www.bsb-dampers.co.uk

TransformationPiece

FD-C and FSD-C model damper

Both the FD-C and FSD-C dampermodels accept the FD-R transformationpiece, and are supplied loose.

A(Duct Height & Width -4mm)

D C E

Dia. B

F *

Dia. B

* This dimension varies according to thesize of the transformation piece. Pleasesee dimension table Page 2 for details.

A(Duct Height & Width -4mm)

Page 4: FD-R Series - BSB · The fitting of the FD-R transformation piece to the FD-C or FSD-C series damper is considered to have no adverse affects on the damper performance that it is

FD-R Square to Round Transformation Piece

Quadrilateral Connection:

Material:G Galvanised

FD-R / 150/200 - G

FD-R SeriesSquare to Round Transformation Piece

Air, Fire and Smoke Control Products in the BSB Range:

For full details of the complete BSB Product Range, please refer to our individual product brochures, sales office or website.

FSD-TD SeriesFire/Smoke Dampers

SC SeriesSmoke Dampers

Control Systems FD SeriesFire Dampers

SF SeriesSlimFit Dampers

SS SeriesSlimSeal Dampers

HD SeriesHeavy Duty Dampers

BD SeriesBackdraught Dampers

DD SeriesDuct Dampers

FD-R SeriesDuctwork Transformation Piece

FD-C SeriesCircular Fire Dampers

FSD-C SeriesCircular Fire/Smoke Dampers

M A D E I N B R I TA I N

SOLD TO THE WORLD

BSB Engineering Services LimitedUnit 56, Trinity Trade Centre, Mill Way, Sittingbourne, Kent ME10 2PD, UK • Tel: +44 (0)1795 422609 • Fax: +44 (0)1795 429543For purchase orders and order related enquiries, please email: [email protected] pricing, technical and general enquiries, please email: [email protected]: www.bsb-dampers.co.uk • A member of the Maico groupBSB Engineering Services Ltd. reserves the right to modify or withdraw any specification without prior notice that may result from continuous product development. The information contained within this brochure is correct at the time of going to press. (FDR-09-2014)

bre Testing facilityMember of HEVAC AssociationMember of ADCAS Association

The FD-R transformation piece will be supplied loose to allow thefitting of the damper and FD-R pieces where space is at a premiumand manipulation of installed ductwork is not possible. They aresupplied separately to suit site ductwork changes not accounted for atthe ductwork system design stage.

The FD-R transformation piece is supplied as a single item so as to beflexible in meeting your site requirements where differing quadrilateralconnections may be required at each end of the damper.


Recommended