Low noise levelWith a volume of just 20dB in sleep mode, the ARTCOOL range is remarkably quiet. You can control the climate of your bedroom for a cool and perfectly peaceful night’s sleep, just the way it should be.
3-Dimensional air flowDesigned like a work of art, ARTCOOL lives up to its design with the 3 dimensional air flow. It cools evenly as well as offering fast cooling from the front and both sides.
Personalise your airconWith our ground-breaking design, you can change the look of your air conditioning effortlessly. Simply print your favourite photo and pop it in the frame at the front of the unit. When you fancy a change, you know what to do...
Award winningSee a different side to air conditioning with LG ARTCOOL – one of the most discreet and stylish range on the market. It’s packed with all of the clever features you would expect. These award-winning units are perfect for those with an eye for style.
• NEOPlasma• AnticorrosionGoldFinTM
• Changeablepicture/photo• 3-dimensionalairflow• EZRemotecontrol
Gallery
A09AW1 A12AW1
FeaturesandBenefits
Pictures are easily changeable at anytime with your ownpictures/photos.
Indoor 20dB Outdoor 45dB
Gallery
A09AW1 A12AW1
Specifications
LG Air Conditioning & Energy Solutions 250-252 Bath Road, Slough, Berkshire SL1 4DX A
09AW1,A12AW1/10-2011
Note:Specifications,designandfeaturearesubjecttochangewithoutpriornotice.
Model Indoor Unit Outdoor UnitCoolingCapacity (Min/Rating/Max) WHeatingCapacity (Min/Rating/Max) WInput Cooling W Heating WRunningCurrent Cooling/Heating AStartingCurrent Cooling/Heating APower Supply ø,V, HzE.E.R Cooling W/WC.O.P Heating W/WENERGYEfficiencyClass Cooling/HeatingNoiseLevel Indoor(H/M/L/Sleep) dB(A)±3(SoundPress,1m) Outdoor,Max dB(A)±3AirFlow Indoor,Max m3/min Outdoor,Max m3/minDehumidificationRate I/hRefrigerantcharge(R410A) gSVCValve Liquid mm(inch) Gas mm(inch)Dimensions Indoor mm(W*H*D) Outdoor mmNetWeight Indoor kg Outdoor kgPower to...Interconnecting CableMax.PipingLength/Height mAdditionalRefridgerantCharge g/mSuggested Circuit Breaker Type C A
A09AW1 NF2 A09AWU UF2
1,300/2,700/3,5001,300/3,500/4,200
830 960
3.8/4.4<4.5/5.2
1,220-240,503.25 3.65 A/A
35/29/25/22488261.2
1,0006.35(1/4)9.52(3/8)
600x600x146770x545x245
1532
Indoor3-Core+Earth
15/720(>7.5m)
10
A12AW1 NF2 A12AWU UF2
1,300/3,500/4,0001,300/4,200/5,000
1,090 1,160 4.9/5.2<5.7/6.9
1,220-240,503.21 3.62A/A
39/32/25/23489.5341.5
1,0006.35(1/4)9.52(3/8)
600x600x146770x545x245
1532
Indoor3-Core+Earth
15/720(>7.5m)
10
Libero R
Libero E
Hero
ART COOL Mirror
600
60
0
146
2.6~3.5kW
EnergysavingAchievea7%EERand12%COPimprovement**with LG’s DC Inverter technology. Inverter heat pump products offer higher energy savings than constant-speed, non-inverter units.
**Comparison:InvertermodelvsNonInvertermodel.
Low noise levelsInverter technology, BLDC motor technology, and LG’suniquenewSkewFantechnologyallowforexceptionally low noise levels of 19dB.
Installation support clipInstallation support clip makes installation and servicing easier.
Key featuresSee a different side to air conditioning with LG ARTCOOL – one of the most discreet and stylish ranges on the market. Small, but packed with all of the clever features you would expect. These award-winning units are perfect for those with an eye for style.
•Highefficiency•Optimisedcoolingandheating•Virusandallergyfilter•Quickandeasyinstallation•Plasmaandtriplefilter•CompatiblewiththeInverterMultiSystem
CA09AW*CA12AW*
9,000 Btu/h 12,000 Btu/h 18,000 Btu/h 24,000 Btu/h
3.5
4.6 4.6
4.04.2
3.8
3.23.6
9,000 Btu/h 12,000 Btu/h
4.6 4.6
4.04.2
Cooling
Heating
*(R = Mirror
V = Silver
W=White)Silver White
Mirror
LG Air Conditioner
Conventional Inv.
Woods
19dB
22dB
26dB
Library
Conventional On / Off
36dB
32dB
Non INVINV
IMPROVEMENT7%
INV
IMPROVEMENT
12%
Non INV
EER(Cooling) COP(Heating)
FeaturesandBenefits
CA09AW*CA12AW*
Specifications
LG Air Conditioning & Energy Solutions 250-252 Bath Road, Slough, Berkshire SL1 4DX
Model Indoor Unit Outdoor UnitCooling Capacity kWHeating Capacity kWLowTemp.HeatingCapacity(-7ºC) kWPowerInput Cooling/Heating WEER W/WCOP W/WAnnual energy consumption Cooling kWhEnergyEfficiencyClass Cooling/HeatingPowerSupply Ø/V/HzAirFlowRate Indoor,Max m3/min Outdoor,Max m3/minSoundPressureLevel Indoor,H/M/L/SL dB(A)±3 Outdoor,Max dB(A)±3SoundPowerLevel Indoor,Max dB(A) Outdoor,Max dB(A)OperationRange Cooling(Outdoor) °C Heating(Outdoor) °CCompressor Type Fan(Indoor) MotorOutput WFan(Outdoor) MotorOutput WRunningCurrent Cooling/Heating AStartingCurrent Cooling/Heating AMaxCurrent Cooling/Heating ASuggested Circuit Breaker Type C APower Supply to Interconnecting Cable Refrigerant Charge R410A gAdditionalRefrigerantcharge g/mPipingConnections LiquidSide mm(in) GasSide mm(in)PipingLength(Min/Max) mMax.ElevationDifference mDrainHose(O.D/I.D.) mmDimensions Indoor(WxHxD) mm Outdoor(WxHxD) mmNetWeight Indoor kg Outdoor kg
Accessory Options Wired Remote Dry Contact P1485 Interface
CA09AW* NB0 E09SQU UB00.89~2.50~3.700.89~3.2~4.10
3.00 600/7704.174.16300A/A
1/220-240/501227
38/33/23/19475765
-5~48-10~24Rotary
2043
2.66/3.4412.5m)6.35(1/4)9.52(3/8)3/157
21.5/16.0885x285x205717x483x230
1028
PQRCVSL0,PQRCVSL0QWPQDSB,PQDSB1,PQDSBC
-
CA12AW* NB0 E12SQU UB0
0.89~3.50~4.040.89~4.0~5.10
3.60 1010/1050
3.473.81505A/A
1/220-240/501227
39/33/23/19475765
-5~48-10~24
1P Rotary2043
4.60/4.65
EnergysavingAchievea7%EERand12%COPimprovement**with LG’s DC Inverter technology. Inverter heat pump products offer higher energy savings than constant-speed, non-inverter units.
**Comparison:InvertermodelvsNonInvertermodel.
Auto cleaningThe auto clean function dries the wet heat exchanger to help prevent mold and bacteria from breeding. This reduces odours and the amount of manual cleaning needed.
Auto clean takes about 30 min to complete.
Installation support clipInstallation support clip makes installation and servicing easier.
Key features•Highefficiency•Optimisedcoolingandheating•Virusandallergyfilter•Quickandeasyinstallation•Plasmaandtriplefilter•CompatiblewiththeInverterMultiSystem
CA18AW*CA24AW*
FeaturesandBenefits
Non INVINV
IMPROVEMENT7%
INV
IMPROVEMENT
12%
Non INV
EER(Cooling) COP(Heating)
*(R = Mirror
V = Silver
W=White)Silver White
Mirror
Step 1Runs at a very low fan speed to dry the evaporator.
Step 2Removes the source of mold by use of the Plasmafilter.
9,000 Btu/h 12,000 Btu/h 18,000 Btu/h 24,000 Btu/h
3.5
4.6 4.6
4.04.2
3.8
3.23.6
9,000 Btu/h 12,000 Btu/h
4.6 4.6
4.04.2
Cooling
Heating
CA18AW*CA24AW*
Specifications
LG Air Conditioning & Energy Solutions 250-252 Bath Road, Slough, Berkshire SL1 4DX
Model Indoor Unit Outdoor UnitCooling Capacity kWHeating Capacity kWLowTemp.HeatingCapacity(-7ºC) kWPowerInput Cooling/Heating WEER W/WCOP W/WAnnual energy consumptionCooling kWhEnergyEfficiencyClass Cooling/HeatingPowerSupply Ø/V/HzAirFlowRate Indoor,Max m3/min Outdoor,Max m3/minSoundPressureLevel Indoor,H/M/L/SL dB(A)±3 Outdoor,Max dB(A)±3SoundPowerLevel Indoor,Max dB(A) Outdoor,Max dB(A)OperationRange Cooling(Outdoor) °C Heating(Outdoor) °CCompressor Type Fan(Indoor) MotorOutput WFan(Outdoor) MotorOutput WRunningCurrent Cooling/Heating AStartingCurrent Cooling/Heating AMaxCurrent Cooling/Heating ASuggested Circuit Breaker Type C APower Supply to Interconnecting Cable Refrigerant Charge R410A gAdditionalRefrigerantcharge g/mPipingConnections LiquidSide mm(in) GasSide mm(in)PipingLength(Min/Max) mMax.ElevationDifference mDrainHose(O.D/I.D.) mmDimensions Indoor(WxHxD) mm Outdoor(WxHxD) mmNetWeight Indoor kg Outdoor kg
Accessory Options Wired Remote Dry Contact P1485 Interface
CA18AW* NC0 S18AQU UC00.9 ~ 5.2 ~ 6.00.9 ~ 6.3 ~ 9.0
5.50 1,500/1,650
3.473.82750A/A
1/220-240/5019.560
42/40/35/29516370
-10~48-10~24
Twin Rotary2084
6.6/7.37.5m)6.35(1/4)12.7(1/2)3/20
1521.5/16.0
1030x325x245870x655x320
15.546
PQRCVSL0,PQRCVSL0QWPQDSB,PQDSB1,PQDSBC
PMNFP14A0
CA24AW* NC0 S24AQU UC00.90~7.03~8.650.90~8.44~11.40
8.50 2,190/2,330
3.213.621095A/A
1/220-240/502260
45/40/35/29536570
-10~48-10~24
Twin Rotary20124
9.8/10.47.5m)9.52(3/8)15.88(5/8)3/30
1521.5/16.0
1030x325x245870x800x320
15.560
PQRCVSL0,PQRCVSL0QWPQDSB,PQDSB1,PQDSBC
PMNFP14A0
Note:1.Capacitiesarebasedonthefollowingconditions: Cooling:-IndoorTemperature27°CDB/19°CWB -OutdoorTemperature35°CDB/24°CWB Heating: -IndoorTemperature20°CDB/15°CWB -OutdoorTemperature7°CDB/6°CWB Note:2.Annualenergyconsumption:basedonaverageuseof500runninghoursper year at nominal condition
Libero R
Libero E
Hero
ART COOL Mirror
32
5
1030 245
5.3kW 7.0~8.0kW
CA18AW,CA24AW/10-2011
E09SQE12SQE18SQE24SQ
E09SQ/E12SQ
E18SQ/E24SQ
EnergysavingAchievea7%EERand12%COPimprovement**with LG’s DC Inverter technology. Inverter heat pump products offer higher energy savings than constant-speed, non-inverter units.
**Comparison:InvertermodelvsNonInvertermodel.
Low noise levelsInverter technology, BLDC motor technology, and LG’suniquenewSkewFantechnologyallowforexceptionally low noise levels of 19dB.
Installation support clipInstallation support clip makes installation and servicing easier.
Key features•Optimisedcoolingandheating•Virusandallergyfilter•Tripleairfilter•Quickandeasyinstallation•Lownoiseandeasyinstallation•Autocleaning•CompatiblewithInverterMultiSystem
LG Air Conditioner
Conventional Inv.
Woods
19dB
22dB
26dB
Library
Conventional On / Off
36dB
32dB
Non INVINV
IMPROVEMENT7%
INV
IMPROVEMENT
12%
Non INV
EER(Cooling) COP(Heating)
9,000 Btu/h 12,000 Btu/h 18,000 Btu/h 24,000 Btu/h
3.5
4.6 4.6
4.04.2
3.8
3.23.6
9,000 Btu/h 12,000 Btu/h
4.6 4.6
4.04.2
Cooling
Heating
FeaturesandBenefits
E09SQE12SQE18SQE24SQ
Specifications
LG Air Conditioning & Energy Solutions 250-252 Bath Road, Slough, Berkshire SL1 4DX
Model Indoor Unit Outdoor UnitCooling Capacity kWHeating Capacity kWLowTemp.HeatingCapacity(-7ºC) kWPowerInput Cooling/Heating WEER W/WCOP W/WAnnual energy consumption Cooling kWhEnergyEfficiencyClass Cooling/HeatingPowerSupply Ø/V/HzAirFlowRate Indoor,Max m3/min Outdoor,Max m3/minSoundPressureLevel Indoor,H/M/L dB(A)±3 Outdoor,Max dB(A)±3SoundPowerLevel Indoor,Max dB(A) Outdoor,Max dB(A)OperationRange Cooling(Outdoor) °C Heating(Outdoor) °CCompressor Type Fan(Indoor) MotorOutput WFan(Outdoor) MotorOutput WRunningCurrent Cooling/Heating AStartingCurrent Cooling/Heating AMaxCurrent Cooling/Heating ASuggested Circuit Breaker Type C APower Supply to Interconnecting Cable Refrigerant Charge R410A gAdditionalRefrigerantcharge g/mPipingConnections LiquidSide mm(in) GasSide mm(in)PipingLength(Min/Max) mMax.ElevationDifference mDrainHose(O.D/I.D.) mmDimensions Indoor(WxHxD) mm Outdoor(WxHxD) mmNetWeight Indoor kg Outdoor kg
Accessory Options Wired Remote Dry Contact P1485 Interface
E09SQ NB0 E09SQU UB00.89~2.50~3.700.89~3.20~4.10
3.00 600/770
4.174.16300A/A
1/220-240/501227
38/33/23/19475765
-5~48-10~24Rotary
2043
2.66/3.4012.5m)6.35(1/4)9.52(3/8)3/157
21.5/16.0885x285x210 717x483x230
1128
PQRCVSL0,PQRCVSL0QW
PQDSB,PQDSB1,PQDSBC
-
E12SQ NB0 E12SQU UB0
0.90~3.50~4.040.89~4.00~5.10
3.60 1,010/1,050
3.473.81505A/A
1/220-240/501227
39/33/23/19475765
-5~48-10~24Rotary
2043
4.60/4.6512.5m)6.35(1/4)9.52(3/8)3/157
21.5/16.0885x285x210 717x483x230
1128
PQRCVSL0,PQRCVSL0QW
PQDSB,PQDSB1,PQDSBC
-
E18SQ NC0 S18AQU UC0
0.90 ~ 5.20 ~ 6.000.90 ~ 6.30 ~ 9.00
5.50 1,500/1,650
3.473.82750A/A
1/220-240/5019.550
42/40/35/29516370
-10~48-10~24
Twin Rotary3084
6.6/7.37.5m)6.35(1/4)12.70(1/2)3/20
1521.5/16.0
1,030x325x250870x655x320
1746
PQRCVSL0,PQRCVSL0QW
PQDSB,PQDSB1,PQDSBC
PMNFP14A0
E24SQ NC0 S24AQU UC0
0.90~7.03~8.650.90 ~ 8.44 ~ 11.40
8.50 2,190/2,330
3.213.621095A/A
1/220-240/502260
45/40/35/29536570
-10~48-10~24
Twin Rotary30124
9.8/10.47.5m)9.52(3/8)15.88(5/8)3/30
1521.5/16.0
1,030x325x250870x800x320
1760
PQRCVSL0,PQRCVSL0QW
PQDSB,PQDSB1,PQDSBC
PMNFP14A0
Note:1.Capacitiesarebasedonthefollowingconditions: Cooling:-IndoorTemperature27°CDB/19°CWB -OutdoorTemperature35°CDB/24°CWB Heating: -IndoorTemperature20°CDB/15°CWB -OutdoorTemperature7°CDB/6°CWB Note:2.Annualenergyconsumption:basedonaverageuseof500runninghoursper year at nominal condition
2.5~3.5kW 5.3kW 7.0~8.0kW
Libero R
Libero E
Hero
ART COOL Mirror
885
28
5
210Libero R
Libero E
Hero
ART COOL Mirror
1030
32
5
250
E09SQ,E12SQ,E18SQ,E24SQ/10-2011