∆P(B
AR
)
FLOW (GPM)
FLOW (L/MIN)
16
12
8
4
∆P(P
SID
)
0 100 200 300 400 500 600 700 800
J04 Duplex
J06 Duplex
J06 Simplex
J04 Simplex
400 200016001200800 2400 2800- 1.0
- 0.75
- 0.5
- 0.25
- 0
∆P(B
AR
)
FLOW (GPM)
FLOW (L/MIN)
16
12
8
4
∆P(P
SID
)
0 200 400 600 800 1000 1200 1400
J06 Duplex
J06 Simplex
800 4000320024001600 4800- 1.0
- 0.75
- 0.5
- 0.25
- 0
102
Featuring Coreless Element Technology
307/387 Series ASMEFilter AssembliesFlows to 900 gpm (3406 lpm), 307 Series
1500 gpm (5678 lpm), 387 SeriesPressures to 675 psig (46.5 bar)Port Sizes 4," and 6"ANSI Flange Connections
Notes and SpecificationsMaximum Acceptable Class 150: 260 psig (18 bar);Working Pressure: Class 300: 675 psig (46.5 bar) at
200°F (93°C)
Temperature Range: -20°F to 200°F (-29°C to 93°C);140°F (60°C) maximum in HWCF or water glycol fluids
Filter ElementCollapse Pressure: 150 psid (10 bar)
Hydrostatic Test Class 150: 390 psig (26.9 bar)Pressure: Class 300: 1013 psig (69.8 bar)
Materials of Carbon steel option: carbon steelConstruction: housing, nozzles, and flanges;
carbon steel transfer valve body with stainless steel 304L valve balland stem on “D” duplex model
Stainless steel option: 304L stain-less steel housing, nozzles, andflanges; 316 stainless steel trans-fer valve body, valve ball, andstem on “D” duplex model
Finish: Interior finish: coated with rust preventativePermanent cores: tin plated Exterior finish: two coats of zinc primer on carbon steel option
Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1, including latest addenda.
Maximum Clean Element PressureDrop for Bypass Valves. Calculatedclean element pressure drop should notexceed the values listed in the table for theselected bypass valve option.
Pressure Drop Information
Figure 1. Housing Pressure Drop usingfluid with 0.9 S.G. Housing Pressure drop isdirectly proportional to specific gravity.
Element Pressure Drop Factor. Multiply actual flow rate times factor to deter-mine pressure drop with fluid at 150 SUS (32cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity inSUS/150 x new S.G/0.9.
*8904 Series Element ∆P factor (psid/gpm)
Length KZ KP KN KS KT
26" 0.014 0.006 0.005 0.004 0.003
39" 0.009 0.004 0.003 0.003 0.002
*8314 Series Element ∆P factor (psid/gpm)
Length KZ KP KN KS KT
39" 0.0049 0.0026 0.0021 0.0017 0.0011
Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non bypass)
Max. 1 psid 2 psid 3 psid 4 psid 8 psid 15% of Clean ∆P max. ∆P
*Factors listed above have been adjusted to represent the total number of elements per housing.
307 Series with 8904 Elements 387 Series with 8314 Elements
Dimensional Drawings(Contact Pall for engineering drawing)
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255) ©Copyright 1998, 2000, Pall Corporation. All rights reserved. 103
C
BA
G
L
D
E
F
307/87 SE
RIE
S A
SM
E675 P
SI/1500 G
PM
ASSEMBLY P/N: H 3TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8 TABLE 9
REPLACEMENT ELEMENT P/N: HC 8904 F
TABLE 5 TABLE 6 TABLE 1
HC 8314 FTABLE 5 TABLE 6 TABLE 1
Ordering Information
See page 140.
Table 1. Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Table 3. Housing Style OptionsTable 1. Seal Options
Code Seals
H Nitrile
Z Fluorocarbon
Code Style
S Simplex-ports on same side
D Duplex
Table 5. Filter Element Options
Code βx≥200 βx(c)=1000
KZ <1 2.5
KP 3 5
KN 6 7
KS 12 12
KT 25 22
Assembly ElementCode Code** Availability
V 26 307 series
X 39 307 and 387 series* Use code in second column for element part no.
** Nominal length in inches.
*Housings accept 7 elements.
Table 6. Length Options*
Table 7. Bypass Valve Options
Code Description
0 No indicator
B Bleed plug and seal in place of indicator
P Visual indicator with thermal lockout
S Electrical switch with MS receptacle
L Electrical switch with 6" leads
V Electrical/visual indicator
Table 8. Differential Pressure Device Options
Code Cracking Pressure
A 25 psid
B 50 psid
D 18 psid
E 5 psid
F 12 psid
W Non-bypass
Table 2. Housing Option*
Code Option
07 8904 element
87 8314 element
Table 9. Housing Material Options
Code Option
7 Carbon steel
9 304L stainless steel
See page 17 for filter specifications.
Code Port Availability
J04 4" ANSI B16.5 class 150 flanges 307 series
J06 6" ANSI B 16.5 class 150 flanges 307 and 387series
N04 4" ANSI B16.5 class 300 flanges 307 series
N06 6" ANSI B 16.5 class 300 flanges 307 and 387 series
Table 4. Port Options
Dimensions (307 Series)
‘A’ ‘B’ ‘C’ ‘F’Port Simplex Duplex Duplex Duplex ‘L’ ‘L’Size Only Only Only ‘D’ ‘E’ Only ‘G’ V-Length X-Length
J04 11.85 5.90 29.60 8.00 13.78 7.28 14.00 50.06 63.06
J06 11.85 11.81 35.50 6.50 2362 8.46 14.00 59.90 72.90
Dimensions (387 Series)
‘A’ ‘B’ ‘C’ ‘F’Port Simplex Duplex Duplex Duplex ‘L’ ‘L’Size Only Only Only ‘D’ ‘E’ Only ‘G’ V-Length X-Length
J06 17.85 11.81 47.50 8.00 23.62 8.46 20.00 N/A 72.75