For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
FIBE
R O
PTIC
CAB
LEPR
OD
UC
TS
Fiber OpticCable Products> Loose Tube> Central Tube> Fiber Drop > Hybrids > Tight Buffered
CommScope Fiber Optic Cable Products
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fiber O
ptic C
ab
le Prod
ucts
Fiber Optic Cable
CommScope Fiber Optic Cable Products
33
Fiber Optic Cable Overview .................................................................................................... F3Fiber Optic Catalog Numbering Key ....................................................................................... F7Cabled Fiber Specifications Singlemode Fiber ................................................................................................................. F8 Multimode Fiber Specifications ........................................................................................... F11Loose Tube Cable Designs Dry Stranded Loose Tube Armored ..................................................................................... F13 Dry Stranded Loose Tube All-Dielectric ............................................................................... F14 Dry Double Jacketed/Single Armored Stranded Loose Tube ................................................ F15 Arid-Core® Stranded Loose Tube Armored ......................................................................... F16 Arid-Core® Stranded Loose Tube All-Dielectric .................................................................... F17 Arid-Core® Double Jacketed/Single Armored Stranded Loose Tube .................................... F18 Arid-Core® Mini Stranded Loose Tube Armored .................................................................. F19 Arid-Core® Mini Stranded Loose Tube Non-Armored .......................................................... F20 LSZH Arid-Core® Mini Stranded Loose Tube Armored ......................................................... F21 LSZH Arid-Core® Mini Stranded Loose Tube Non-Armored ................................................. F22 High Density Stranded Loose Tube .................................................................................... F23 ADSS Short Span Stranded Loose Tube .............................................................................. F24 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.250in) ............................... F25 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.250in) ....................... F26 Self-Supporting Figure-8 Arid-Core® Dry Stranded Loose Tube Armored (0.250in) .............. F27 Self-Supporting Figure-8 Arid-Core® Dry Stranded Loose Tube Non-Armored (0.250in) ...... F28 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.188in) ............................... F29 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.188in) ....................... F30 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.109in) ............................... F31 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.109in) ....................... F32 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric ................................... F33 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric .............................. F34 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor .................. F35 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor .............. F36Central Tube Cable Designs Central Tube Armored ....................................................................................................... F37 Central Tube All-Dielectric .................................................................................................. F37 Riser-Rated, Indoor/Outdoor Central Tube All-Dielectric ..................................................... F38 Fiber Drop Cable Designs Drop Armored ................................................................................................................... F39 Drop All-Dielectric ............................................................................................................. F40 Messengered Drop (0.109in) ............................................................................................. F41 Messengered Drop (0.083in) ............................................................................................. F42 Figure-8 Mini-Drop (Solid Messenger) ................................................................................ F43 Flat Drop ........................................................................................................................... F44 Toneable Flat Drop ............................................................................................................ F45 LSZH, Indoor/Outdoor Central Tube All-Dielectric .............................................................. F46ConQuest® Fiber Optic Products ............................................................................................ F47Hybrid Cable Designs Fiber/Coax Designs ........................................................................................................... F51 Fiber/Twisted Pair Designs .................................................................................................. F53 Fiber/Tone Wire Designs .................................................................................................... F55Tight Buffered Cable Designs Riser-Rated, Indoor/Outdoor LSZH Distribution .................................................................. F58 Riser-Rated, Indoor/Outdoor LSZH Cordage ...................................................................... F59 Riser-Rated, Indoor Distribution .......................................................................................... F60 Riser-Rated, Indoor Cordage .............................................................................................. F61 Plenum Rated, Indoor Distribution ...................................................................................... F62 Plenum-Rated, Indoor Cordage ......................................................................................... F63Packaging and Shipping Information ..................................................................................... F64
Fiber O
ptic C
ab
le Prod
ucts
F2
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
CommScope Fiber Optic Cable ProductsProven Quality and Performance
The Cable Industry’s Fiber SupplierTM
Better fiber equals better fiber optic cable. CommScope provides key optical and geometrical features in its standard singlemode fiber for fusion splice compatibility with other fiber manufacturers and legacy fiber. LightScope ZWP® singlemode optical fiber cable continues a CommScope tradition of being a leader in manufacturing innovative and performance-enhanced products for the cable industry. LightScope ZWP optical fiber cable makes available 30% more usable transmission spectrum, which can be used for return path, enhanced video services such as video on demand (VOD) or Dedicated Wavelength Services for business or other demanding applications.
CommScope has developed key families of fiber optic cables specifically to be used throughout the HFC communication hierarchy as well as an offering of fiber optic components including connectors and other passive devices that are commonly required in broadband infrastructure.
Outside Plant Cables for Standardand Rugged EnvironmentsFor direct buried, underground conduit and aerial installations, CommScope offers several designs, which include a variety of loose tube cables. Design options include Drop Armored, a smaller, lighter weight Central Tube cable construction; Central Tube, Flat Drop, and Stranded Loose Tube cables. Craft friendly product solutions are a foremost requirement in today’s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easy-to-handle constructions in our fiber product offering. For example, our Dry Loose Tube family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications. Any of these cables may be factory-installed in a variety of CommScope’s ConQuest® premium high density polyethylene conduit including Toneable ConduitTM – a patented location and damage prevention solution.
Indoor/Outdoor Cables for Strength and Safety - Including Low-Smoke Zero-Halogen (LSZH) TypesCommScope’s design for these cables offer construction and jacketing suitable for outside usage yet comply with UL and CSA riser (OFNR) or plenum (OFNP) flame standards. This design allows you to run cable through the building entrance without having to terminate and splice different cables together which results in significant savings in time and labor. Cable types include dielectric central tube designs, dielectric stranded loose tube cables and Triathlon®, a specially designed low-smoke/zero halogen distribution and cordage cable construction.
Premise Cables for Safety and PerformanceCommScope’s premises cables are designed to handle the unique stresses of indoor applications. Design options include riser and plenum-rated distribution and cordage cables.
32
Fib
er O
ptic
Ca
ble
Pro
duct
s
F3
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Test Reports -A Higher Standard for Higher SpeedsEvery reel of CommScope fiber optic cable is subjected to stringent testing throughout the entire manufacturing process. Our state-of-the-art process controls and testing systems ensure that every meter of CommScope cable consistently meets or exceeds our high standards.
To prove that our fiber optic cables exceed industry standards, we go to the extra step of attaching an individual cable test report to each reel. In addition to the paper copy of the test reports, we also offer WebTrak®, a web program that puts cabling factory results on-line for all of our fiber optic cables. It is our understanding that sometimes this critical test information is misplaced or
never makes it to the end-user. With WebTrak, it is easy to find that important paperwork; CommScope’s web interface puts factory testing reports for individual cables on-line for 24 hour immediate access.
The patented and trademarked WebTrak program resides on our commscope.com website for quick access from any computer. For access to the electronic test reports, all the installers need is the 11 digit serial number printed on the cable jacket and a footage or meter marker for reference. Installers can then enter this number on the WebTrak portion of the CommScope website and pull up the cable’s factory test results from anywhere in the world at any time of the day or night.
• Provides documentation of CommScope fiber optic cable performance, allowing a convenient way to track a reel of cable and verify performance.
• Provides an alternative to managing paper reports. With WebTrak, you can get all the information you need on-line.
• Provides quick verifications to ensure the product meets or exceeds performance requirements, should there be a performance issue in the field.
• Provides easy 24/7 access via the internet.
WebTrak is just one more example of how CommScope listens to our customers and delivers. You get proof-positive that the cable you purchase will perform to the level you require. Remember, a network is only as good as the cable that connects it. Specify the cables that make networks work — fiber optic cables from CommScope.
Request a FREE BroadbandApplications & Construction LibraryCommScope’s Broadband Applications & Construction Library includes a 5-piece set of valuable reference manuals plus a DVD containing essential training videos on topics such as connectorization, expansion loop formation and fiber optic splicing. These tools teach you how to protect the integrity of your broadband plant while lowering operating/installation costs. From construction and installation practices, to performance and testing of cable – CommScope Construction Manuals are simply a “must-have” for anyone upgrading or maintaining broadband networks. Download a PDF version at our website: http://www.commscope.com or request a set by phone at 1-800-982-1708.
CommScope’sBroadband Resource Center TM
This repository of experience, knowledge, services and tools is provided to CommScope customers to assist installers, technicians, engineers, designers and managers of broadband service providers. Tools in various media and formats include: SpanMaster® software for cable sag and tension calculations; center conductor sizing guides; attenuation slide rules; and call center spec assistance and review. Call us at 1-866-333-3BRC (3272) or e-mail
[email protected] for answers to product questions or issues related to any
CommScope broadband product.
33
Fiber O
ptic C
ab
le Prod
ucts
F4
CommScope Outside Plant Cables Robust Dielectric and Armored Constructions
All CommScope Outside Plant (OSP) cables are designed and manufactured to provide outstanding mechanical and optical performance. This cable family includes a loose tube construction to provide multiple levels of protection for the fiber strands. We manufacture all loose tube cables with appropriate Excess Fiber Length (EFL) to ensure, that when properly installed, the fiber strands will remain strain-free, which is essential to good optical performance and longevity. Our heavy-duty products are engineered to withstand the rigors of environmental extremes.
There are many cable choices when considering applications that require environmental protection and provide for network diversity. CommScope cable surpasses requirements in the aerial, underground and conduit applications. We offer self-support cable for aerial environments and cable-in-conduit or armored cables for extra protection in burial applications.
CommScope manufactures cables that are lightweight, flexible and especially suited for aerial cable installations. Our loose tube cables are available in armored and all-dielectric versions.
OSP Fiber Optic Cable Design Options Include:
•Drop - a small, lightweight Central Tube cable designed for use when space is at a minimum; features a robust PBT buffer tube and is available in fiber counts up to 12
•Central Tube - armored and dielectric construction for point-to-point installations in counts up to 96 arranged in easy-to-handle color-coded subunits of 12 fiber each
•Stranded Loose Tube - for direct buried, underground conduit and aerial installations; design variations range from all-dielectric to armored constructions with up to 576 fibers
Dry Loose TubeCraft friendly product solutions are a foremost requirement in today’s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easy-to-handle constructions in our fiber product offering. The latest example is our new Dry Loose Tube cable design. This family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications and meets all of the requirements for outside plant cable.
Arid-Core® Moisture BarrierCommScope defeats moisture with a unique multi-level approach. In addition to tough outer jacketing, we employ Arid-Core, a super-absorbent polymer technology. Arid-Core is applied between the jacket and the buffer tubes in stranded loose tube cables, and coats the central tubes of drop armored and central tube cables. When moisture meets Arid-Core, the polymer swells to prevent moisture migration - it acts as a mechanical block to prevent further water penetration.
Drop CablesCommScope’s Drop family of cables offer craft friendly access product solutions for Fiber to the Premise (FTTP) applications designed for use as systems develop commercial services and expand networks to non-traditional customers. The design of drop cables compliments the needs often found for the last mile of your fiber network. Drop cables offer a compact, flexible and cost-efficient configuration that provides low-loss performance when twelve fibers or less are needed. Drop cables are commonly used to branch from the main cable route to outlying distribution points or the premise. All drop cables can be pre-installed in conduit. CommScope OSP fiber optic cables are designed to meet or exceed the
requirements of Telcordia, EIA/TIA, REA/RUS, IEC and RUS industry standards.
32 For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fib
er O
ptic
Ca
ble
Pro
duct
s
F5
Stranded Loose Tube• Available in All-Dielectric and Armored designs with up to 576 fibers
• For Direct Buried, Underground Conduit, and Aerial installations
• Available in ADSS and Figure-8 constructions
• Hybrid configurations that include coax or copper conductors are available
Mini-Diameter Stranded Loose Tube• Smaller, lightweight cable design utilizing 2.0mm buffer tubes
• Available with up to 144 fibers in Armored, All- Dielectric and LSZH designs
• Improved ease of handling and better utilization of duct space
CommScope Cable Constructions
33For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fiber O
ptic C
ab
le Prod
ucts
F6
Drop• Cost effective, low fiber count cables for outside plant applications
• Wide variety of flexible, versatile, and craft-friendly products available
• For Direct Buried, Underground Conduit, and Aerial Drop applications
• Small, lightweight cable designs developed for ease of installation
Messenger Figure-8 • Multiple messenger size options for increased versatility in designs with up to 60 fibers
• Allows easy, one-step installation resulting in cost savings
• Armored and Non-Armored versions with .250” messenger available with up to 288 fibers
Central Tube• Available in All-Dielectric and Armored designs with up to 96 fibers
• Effective solution for point-to-point installations
• Robust constructions offer excellent fiber protection
• Single buffer tube saves time and reduces termination costs
Indoor/Outdoor Stranded Loose Tube• Riser, Plenum, and Low Smoke Zero Halogen (LSZH) constructions
• Eliminates the need for a splice point when entering a building
• Tough enough for the OSP environment and flame rated for indoor use
Hybrid Cables• Flexibility and options for future growth in a single cost-effective cable run
• Easier material management
• Capable of voice transmission, cable location, and site powering
Premise Cables• Complete line of Riser and Plenum rated cables for indoor use
• Engineered to provide excellent mechanical and optical performance
• FiberGuard Aluminum Interlocking Armor available
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fiber Optic Catalog Numbering KeySteps to Building the Catalog Number for the Cable You Need!
CABLE STYLE (Position 1)
D ......Dry O .....Outdoor (Arid Core® Standard) S .......Self-Supporting (ADSS) M .....Messenger P .......Plenum R.......Riser Z ......Zero Halogen
FIBER COUNT* (Positions 2, 3, & 4)
Total Fiber Count (in increments of two)
*Substitute for “XXX” variable in catalog number.
CABLE MARKING (Position 9)
F .........Jacket Sequentially Marked in Feet (standard)
M ........Jacket Sequentially Marked in Meters
X .........Custom Print Required
FIBER TYPE (Positions 7 & 8)
Singlemode8W .........LightScope ZWP® Dispersion-Unshifted, Matched-Clad, Singlemode Fiber8F ...........Bend Insensitive Singlemode Fiber
8T ...........LightScope NZDTM Non-Zero Dispersion- Shifted, Singlemode Fiber
Multimode6F ...........62.5µm, FDDI Grade, Multimode Fiber5M .........LazrSPEED® 150, 50µm, Multimode FiberCM .........Composite (Singlemode & Multimode)
HybridsHY ..........Fiber/Copper *XY variable in catalog number
CONSTRUCTION (Positions 5 & 6)
Loose Tube CablesLA ..........Stranded Loose Tube Armored
LN .........Stranded Loose Tube Non-Armored
L2 ..........Stranded Loose Tube Double Jacketed, Single Armored LZ ..........Indoor/Outdoor Stranded Loose Tube, Aluminum Interlocking ArmorDA .........Drop ArmoredDN ........Drop Non-ArmoredDF .........Flat DropMN ........Mini-Drop Non-ArmoredCA .........Central Tube ArmoredCN ........Central Tube Non-Armored, All-Dielectric Tight Buffered CablesDS .........Distribution IC .......InterconnectSP ..........Simplex ZC ......Zipcord
CABLE CONSTRUCTION SPECIFICS (Position 10)
• For outdoor and indoor/outdoor loose tube cables, this value indicates the fiber content per subunit: 01-12 .......... Fiber Count Per Subunit
• For indoor distribution cables, this value indicates additional information pertaining to the cable construction: SU ............... Single Unit Construction MU ..............Multi-Unit Construction
• For cordage cables, this value indicates the outside diameter: 16 ...............1.6mm Jacket Outer Diameter 25 ...............2.5mm Jacket Outer Diameter 29 ...............2.9mm Jacket Outer Diameter
COLOR FIELD (Positions 11 & 12)• For outdoor cables, this field designates the tracer/stripe requirements: NS .................No Stripe (Std) WH ....................White BL ..................Blue YL ......................Yellow OR ................Orange VI .......................Violet GR ................Green
• For indoor/outdoor cables, this field designates the jacket color: BK .................Black
• For indoor cables, this field designates jacket color: OR .........Orange -62.5 µm multimode and composite cables YL ..........Yellow - singlemode cables AQ .........Aqua - 50 µm multimode LazrSPEED® cables
Note: Non-standard jacket colors are available. (minimum order required) Please contact your Customer Service Representative for additional information.
“ZZ” variable in catalog number
NOTES
When Positions 7 & 8 are CM (composite cables), positions 14-23 are required.Positions 14 & 15 ............. Singlemode fiber type
Positions 16 - 18 ............. Singlemode fiber count (aaa variable in the catalog number)
Positions 19 & 20 ............. Multimode fiber type
Positions 21 - 23 .............. Multimode fiber count (bbb variable in the catalog number)
Please note that positions 13 and above are often used to differentiate similar cable constructions. Please see the individual product pages for additional part number details.
CommScope Catalog Number Position 1 2 3 4 5 6 7 8 9 10 11 12
F7
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Type 8W Singlemode Fiber SpecificationsAvailable in All CommScope Cable Types
F8
Physical Characteristics Cladding Diameter 125 ± 0.7 µmCore/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µmCoating Diameter (colored) 254 ± 7 µmCoating/Cladding Concentricity Error, maximum 12 µmClad Non-Circularity < 1%
Mechanical CharacteristicsProof Test 100 kpsi (.69 Gpa)Coating Strip Force 0.3 - 2.0 lbf (1.3 - 8.9 N)Fiber Curl > 4 mDynamic Fatigue Parameter > 20 ndMacrobend 100 turns @ 50 mm mandrel 1310/1550 nm 0.05 dB maximumMacrobend 100 turns @ 60 mm mandrel 1625nm 0.05 dB maximumMacrobend 1 turn @ 32 mm mandrel 1550 nm 0.05 dB maximum
Optical Characteristics, Wavelength SpecificAttenuation, Loose Tube Cable 1310 nm 0.34 dB/km 1385 nm 0.31 dB/km 1550 nm 0.22 dB/km Attenuation, Tight Buffer Cable 1310 nm 0.50 dB/km 1385 nm 0.50 dB/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm 9.2 + 0.3 µm 1385 nm 9.6 + 0.6 µm 1550 nm 10.4 + 0.5 µm Group Refractive Index 1310 nm 1.467 1385 nm 1.468 1550 nm 1.468Dispersion 1310 nm 3.2 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km)
Optical Characteristics, General
Point Defects, maximum 0.10 dBCutoff Wavelength < 1260 nmZero Dispersion Wavelength 1302 - 1322 nmZero Dispersion Slope 0.090 ps/(km-nm-nm)Polarization Mode Dispersion Link Design Value < 0.06 ps/sqrt(km)
Environmental Characteristics
Temperature Dependence -60°C to +85°C < 0.05 dBTemperature Humidity Cycling -10°C to +85°C up to 95% RH < 0.05 dBWater Immersion, 23 + 2°C < 0.05 dBHeat Aging, 85 + 2°C < 0.05 dB
Zero Water Peak: Dispersion-Unshifted, Matched-Clad Singlemode FiberStandards Compliance: ITU-T G.652.D
Specifications are subject to change without notice.
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
F9
Physical Characteristics Cladding Diameter 125 ± 0.7 µmCore/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µmCoating Diameter (colored) 254 ± 7 µmCoating/Cladding Concentricity Error, maximum 12 µmClad Non-Circularity < 1%
Mechanical CharacteristicsProof Test 100 kpsi (.69 Gpa)Coating Strip Force 0.3 - 2.0 lbf (1.3 - 8.9 N)Fiber Curl > 4 mDynamic Fatigue Parameter > 18 ndMacrobend 100 turns @ 50 mm diameter (maximum) 1550 nm 0.01 dB 1625 nm 0.05 dBMacrobend 10 turns @ 30 mm diameter (maximum) 1550 nm 0.2 dB 1625 nm 0.5 dBMacrobend 1 turn @ 30 mm diameter (maximum) 1550 nm 0.02.dB Macrobend 1 turn @ 20 mm diameter (maximum) 1550 nm 0.2 dB
Optical Characteristics, Wavelength SpecificAttenuation, Loose Tube Cable 1310 nm 0.36 dB/km 1385 0.33 dB/km 1550 nm 0.25 dB/km Attenuation, Tight Buffer Cable 1310 nm 0.50 dB/km 1385 nm 0.50 dB/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm 8.9 + 0.4 µm 1550 nm 10.0 + 0.5 µm Group Refractive Index 1310 nm 1.467 1385 nm 1.467 1550 nm 1.468 Dispersion 1310 nm 3.5 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km)
Optical Characteristics, General
Point Defects, maximum 0.10 dBCutoff Wavelength < 1260 nmZero Dispersion Wavelength 1302 - 1322 nmZero Dispersion Slope 0.092 ps/(km-nm-nm)Polarization Mode Dispersion Link Design Value < 0.06 ps/sqrt(km)
Environmental CharacteristicsTemperature Dependence -60°C to +85°C < 0.05 dBTemperature Humidity Cycling -10°C to +85°C up to 95% RH < 0.05 dBWater Immersion, 23 + 2°C < 0.05 dBHeat Aging, 85 + 2°C < 0.05 dB
Dispersion-Unshifted, Matched-Clad Singlemode FiberStandards Compliance: ITU-T G.657.A
Bend Insensitive Type 8F Singlemode Fiber SpecificationsAvailable in All CommScope Cable Types
Specifications are subject to change without notice.
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
F10
Non-Zero Dispersion Shifted Singlemode FiberStandards Compliance: ITU-T G.655.C, D
LightScope NZDTM Type 8T Singlemode Fiber SpecificationsAvailable in CommScope Outside Plant Cable Types
Physical Characteristics Cladding Diameter 125 ± 0.7 µm
Core/Clad Offset < 0.5 µm
Coating Diameter (uncolored) 245 ± 5 µm
Coating Diameter (colored) 256 ± 8 µm
Coating/Cladding Concentricity Error, maximum 10 µm
Clad Non-Circularity < 0.7%
Mechanical Characteristics
Proof Test 100 kpsi (.69 Gpa)
Coating Strip Force 0.3 - 2.0 lbf (1.3 - 8.9 N)
Fiber Curl > 4 m
Dynamic Fatigue Parameter > 20 nd
Macrobend 100 turns @ 75mm mandrel 1550 and 1625 nm 0.05 dB maximum
Macrobend 1 turn @ 32mm mandrel
1550 and 1625nm 0.50 dB maximum
Optical Characteristics, Wavelength Specific
Attenuation, Loose Tube Cable
1310 nm 0.45 dB/km 1550 nm 0.25 dB/km
1625 nm 0.34 dB/km
Mode Field Diameter
1550 nm 8.4 + 0.6 µm
1625 nm 8.9 + 0.6 µm
Group Refractive Index
1310 nm 1.471 1550 nm 1.470
1625 nm 1.470
Dispersion
1310 nm -8 ps/(nm-km) (typical)
1550 nm 2.6 to 6 ps/(nm-km) from 1530 - 1565 nm 1625 nm 4.0 to 8.9 ps/(nm-km) from 1565 - 1625 nm
Optical Characteristics, General
Maximum Attenuation at 1385 nm 0.45 dB/km
Point Defects, maximum 0.10 dB
Cutoff Wavelength < 1260 nm
Dispersion Slope < 0.05 ps/(km-nm-nm) at 1550 nm
Polarization Mode Dispersion Link Design Value < 0.04 ps/sqrt(km)
Environmental Characteristics
Temperature Dependence -60°C to +85°C < 0.05 dB
Temperature Humidity Cycling -10°C to +85°C up to 95% RH < 0.05 dB
Water Immersion, 23 + 2°C < 0.05 dB
Heat Aging, 85 + 2°C < 0.05 dB
Specifications are subject to change without notice.
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
62.5 micron, FDDI Grade Multimode FiberStandards Compliance: TIA 492AAAA (OM1)
Type 6F Multimode Fiber SpecificationsAvailable in All CommScope Cable Types
Physical Characteristics
Core Diameter 62.5 ± 2.5 µm
Cladding Diameter 125 ± 1.0 µm
Core/Clad Offset < 1.0 µm
Coating Diameter (uncolored) 245 ± 10 µm
Coating Diameter (colored) 254 ± 7 µm
Coating/Cladding Concentricity Error, maximum 8 µm
Clad Non-Circularity < 1%
Mechanical Characteristics
Proof Test 100 kpsi (.69 Gpa)
Coating Strip Force 0.3 - 2.0 lbf (1.3 - 8.9 N)
Dynamic Fatigue Parameter > 18 nd
Macrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm 0.50 dB maximum
Optical Characteristics, Wavelength SpecificAttenuation, Loose Tube Cable
850 nm 3.0 dB/km
1300 nm 1.0 dB/km
Attenuation, Tight Buffer Cable
850 nm 3.4 dB/km
1300 nm 1.0 db/km
Bandwidth, OFL (Over-Filled Launch)
850 nm 220 MHz - km
1300 nm 500 MHz - km
Group Refractive Index
850 nm 1.496
1300 nm 1.491
1 GB Ethernet Distance
850 nm 300 m
1300 nm 550 m
Optical Characteristics, General
Numerical Aperature 0.275 ± 0.015Point Defects, maximum 0.15 dBZero Dispersion Wavelength 1320 - 1365 nmZero Dispersion Slope, maximum 0.097 ps/(km-nm-nm)
Environmental Characteristics
Temperature Dependence -60°C to +85°C < 0.20 dB
Temperature Humidity Cycling -10°C to +85°C up to 95% RH < 0.20 dB
Water Immersion, 23 + 2°C < 0.20 dB
Heat Aging, 85 + 2°C < 0.20 dB
Specifications are subject to change without notice.
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F12
LazrSPEED 150, 50 micron Multimode FiberStandards Compliance: Exceeds TIA 492AAAB (OM2+)
LazrSPEED® 150 Type 5M Multimode Fiber SpecificationsAvailable in All CommScope Cable Types
Physical Characteristics Core Diameter 50.0 ± 2.5 µmCladding Diameter 125 ± 1.0 µmCore/Clad Offset < 1.5 µm Coating Diameter (uncolored) 245 ± 10 µmCoating Diameter (colored) 255 ± 7 µmCoating/Cladding Concentricity Error, maximum 6 µmClad Non-Circularity < 1%
Mechanical CharacteristicsProof Test 100 kpsi (.69 Gpa)Coating Strip Force 0.3 - 2.0 lbf (1.3 - 8.9 N)Dynamic Fatigue Parameter > 18 ndMacrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm 0.50 dB maximum
Optical Characteristics, Wavelength SpecificAttenuation, Loose Tube Cable 850 nm 3.0 dB/km 1300 nm 1.0 dB/km Attenuation, Tight Buffer Cable 850 nm 3.0 dB/km 1300 nm 1.0 db/km Bandwidth, OFL 850 nm 700 MHz - km 1300 nm 500 MHz - km Bandwidth, Laser 850 nm 950 MHz - km 1300 nm 500 MHz - kmDifferential Mode Delay 850 nm 0.70 ps/m 1300 nm 0.88 ps/mGroup Refractive Index 850 nm 1.483 1300 nm 1.4791 GB Ethernet Distance 850 nm 800 m 1300 nm 600 m10 GB Ethernet Distance 850 nm 150 m
Optical Characteristics, General
Numerical Aperature 0.200 + 0.015Point Defects, maximum 0.15 dBZero Dispersion Wavelength 1297 - 1316 nmZero Dispersion Slope 0.105 ps/(km-nm-nm)
Environmental CharacteristicsTemperature Dependence -60°C to +85°C 0.10 dBTemperature Humidity Cycling -10°C to 85°C up to 95% RH 0.10 dBWater Immersion, 23 + 2°C 0.20 dBHeat Aging, 85 + 2°C 0.20 dB
Specifications are subject to change without notice.
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
Gel-Free Stranded Loose Tube Armored Cable(72 Fiber Version Shown)
PE Outer JacketSteel Tape Armoring
Water Swellable Tape2.5mm Gel-Free Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
Binder
Ripcord (2)
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ Single Armor D-XXX-LA-XY-F12NS 5 0.45/11.5 6.8/17.3 4.5/11.5 607/2700 180/800 78 116 2 - 60 Fibers 62 - 72 Fibers D-XXX-LA-XY-F12NS 6 0.47/12.0 7.1/18.0 4.7/12.0 607/2700 180/800 82 123
74 - 96 Fibers D-XXX-LA-XY-F12NS 8 0.53/13.6 8.0/20.3 5.3/13.6 607/2700 180/800 103 154
98 - 120 Fibers D-XXX-LA-XY-F12NS 10 0.60/15.1 8.9/22.7 6.0/15.1 607/2700 180/800 126 188
122 - 144 Fibers D-XXX-LA-XY-F12NS 12 0.68/17.2 10.2/25.8 6.8/17.2 607/2700 180/800 158 235
146 - 216 Fibers D-XXX-LA-XY-F12NS 18 0.68/17.2 10.2/25.8 6.8/17.2 607/2700 180/800 141 209
218 - 288 Fibers D-XXX-LA-XY-F12NS 24 0.77/19.6 11.6/29.4 7.7/19.6 607/2700 180/800 177 264
Singlemode/Multimode D-XXX-LA-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
Outside Plant Gel-Free Stranded Loose Tube CableArmored
Jacket/Armor Combinations for Buried/Underground/Aerial Applications • 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Specifications are subject to change without notice.CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F13
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Gel-Free Stranded Loose TubeNon-Armored, All-Dielectric Cable(72 Fiber Version Shown)
PE Outer JacketWater Swellable Tape2.5mm Gel-Free Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
BinderRipcord (1)Binder
For Buried/Underground/Aerial Applications • 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment • Lightweight, small design is installer-preferred due to ease of handling • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Specifications are subject to change without notice.
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ 2 - 60 Fibers D-XXX-LN-XY-F12NS 5 0.40/10.2 6.0/15.3 4.0/10.2 607/2700 180/800 45 66 62 - 72 Fibers D-XXX-LN-XY-F12NS 6 0.42/10.6 6.3/15.9 4.2/10.6 607/2700 180/800 49 73
74 - 96 Fibers D-XXX-LN-XY-F12NS 8 0.48/12.2 7.2/18.3 4.8/12.2 607/2700 180/800 64 96
98 - 120 Fibers D-XXX-LN-XY-F12NS 10 0.54/13.8 8.1/20.6 5.4/13.8 607/2700 180/800 83 123
122 - 144 Fibers D-XXX-LN-XY-F12NS 12 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 107 159
146 - 216 Fibers D-XXX-LN-XY-F12NS 18 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 90 134
218 - 288 Fibers D-XXX-LN-XY-F12NS 24 0.72/18.2 10.8/27.3 7.2/18.2 607/2700 180/800 122 181
Singlemode/Multimode D-XXX-LN-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
Outside Plant Gel-Free Stranded Loose Tube CableNon-Armored, All-Dielectric
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.
F14
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Gel-Free Stranded Loose Tube Armored CableDouble Jacketed, Single Armored(72 Fiber Version Shown)
PE Outer JacketSteel Tape ArmoringWater Blocking Tape2.5mm Gel-Free Buffer TubesPE Inner JacketDielectric Strength Member
Strength Elements
250 Micron Fibers
BinderRipcord (2)
Double Jacket for Buried/Underground/Aerial Applications • 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment • Corrugated steel tape is strong yet flexible, providing additional crush and rodent protection • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Double Jacket/ Single Armor D-XXX-L2-XY-F12NS 5 0.59/15.0 8.9/22.5 5.9/15.0 607/2700 180/800 129 192 2 - 60 Fibers 62 - 72 Fibers D-XXX-L2-XY-F12NS 6 0.61/15.4 9.1/23.1 6.1/15.4 607/2700 180/800 134 200
74 - 96 Fibers D-XXX-L2-XY-F12NS 8 0.67/17.0 10.0/25.4 6.7/17.0 607/2700 180/800 160 238
98 - 120 Fibers D-XXX-L2-XY-F12NS 10 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 189 281
122 - 144 Fibers D-XXX-L2-XY-F12NS 12 0.81/20.6 12.2/30.9 8.1/20.6 607/2700 180/800 224 334
146 - 216 Fibers D-XXX-L2-XY-F12NS 18 0.81/20.6 12.2/30.9 8.1/20.6 607/2700 180/800 207 308
218 - 288 Fibers D-XXX-L2-XY-F12NS 24 0.90/23.0 13.6/34.5 9.0/23.0 607/2700 180/800 255 380
Singlemode/Multimode D-XXX-L2-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
Outside Plant Gel-Free Stranded Loose Tube CableDouble Jacketed, Single Armored
Specifications are subject to change without notice.
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F15
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Arid-Core Stranded Loose Tube Armored Cable(72 Fiber Version Shown)
PE Outer JacketSteel Tape ArmoringWater Swellable Tape2.5 mm Gel Filled Buffer TubesWater Blocking GelDielectric Strength Member
Strength Elements
250 Micron Fiber
BinderRipcord (2)
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ Single Armor O-XXX-LA-XY-F12NS/25T 5 0.45/11.5 6.8/17.2 4.5/11.5 607/2700 180/800 81 121 2 - 60 Fibers 62 - 72 Fibers O-XXX-LA-XY-F12NS/25T 6 0.47/11.9 7.0/17.9 4.7/11.9 607/2700 180/800 86 128
74 - 96 Fibers O-XXX-LA-XY-F12NS/25T 8 0.53/13.5 8.0/20.2 5.3/13.5 607/2700 180/800 108 161
98 - 120 Fibers O-XXX-LA-XY-F12NS/25T 10 0.59/15.1 8.9/22.6 5.9/15.1 607/2700 180/800 133 197
122 - 144 Fibers O-XXX-LA-XY-F12NS/25T 12 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 165 246
146 - 216 Fibers O-XXX-LA-XY-F12NS/25T 18 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 153 228
218 - 288 Fibers O-XXX-LA-XY-F12NS/25T 24 0.77/19.5 11.5/29.3 7.7/19.5 607/2700 180/800 194 288
Singlemode/Multimode O-XXX-LA-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
Outside Plant Arid-Core® Stranded Loose Tube CableArmored
Jacket/Armor Combinations for Buried/Underground/Aerial Applications • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Specifications are subject to change without notice.
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripes
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F16
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Arid-Core Stranded Loose TubeNon-Armored, All-Dielectric Cable(72 Fiber Version Shown)
PE Outer JacketWater Swellable Tape2.5 mm Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
BinderRipcord (1)Binder
For Buried/Underground/Aerial Applications • Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) • Lightweight, small design is installer-preferred due to ease of handling
Specifications are subject to change without notice.
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ 2 - 60 Fibers O-XXX-LN-XY-F12NS/25T 5 0.40/10.2 6.0/15.3 4.0/10.2 607/2700 180/800 48 71 62 - 72 Fibers O-XXX-LN-XY-F12NS/25T 6 0.42/10.5 6.2/15.8 4.2/10.5 607/2700 180/800 52 78
74 - 96 Fibers O-XXX-LN-XY-F12NS/25T 8 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 69 103
98 - 120 Fibers O-XXX-LN-XY-F12NS/25T 10 0.54/13.7 8.1/20.6 8.1/13.7 607/2700 180/800 89 133
122 - 144 Fibers O-XXX-LN-XY-F12NS/25T 12 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 114 170
146 - 216 Fibers O-XXX-LN-XY-F12NS/25T 18 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 102 153
218 - 288 Fibers O-XXX-LN-XY-F12NS/25T 24 0.72/18.2 10.7/27.3 7.2/18.2 607/2700 180/800 138 206
Singlemode/Multimode O-XXX-LN-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
Outside Plant Arid-Core® Stranded Loose Tube CableNon-Armored, All-Dielectric
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripes
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F17
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F18
Specifications are subject to change without notice.
Double Jacket/Single ArmorLoose Tube Cable (72 Fiber Version Shown)
PE Outer JacketRipcord (2)Steel Tape ArmoringWater Blocking TapeBinder2.5 mm Buffer TubesPE Inner JacketDielectric Strength Member 250 Micron Fibers
Water Blocking Tape
Strength ElementsRipcord (1)
Multi-Jacketed Stranded Loose Tube CableDouble Jacketed, Single Armored
Jacket/Armor Combinations for Buried/Underground/Aerial Applications • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Double Jacket/ Single Armor O-XXX-L2-XY-F12NS/25T 5 0.59/15.0 8.8/22.4 5.9/15.0 607/2700 180/800 132 196 2 - 60 Fibers
62 - 72 Fibers O-XXX-L2-XY-F12NS/25T 6 0.60/15.3 9.0/23.0 6.0/15.3 607/2700 180/800 138 205
74 - 96 Fibers O-XXX-L2-XY-F12NS/25T 8 0.67/16.9 10.0/25.3 6.7/16.9 607/2700 180/800 164 245
98 - 120 Fibers O-XXX-L2-XY-F12NS/25T 10 0.73/18.5 10.9/27.7 7.3/18.5 607/2700 180/800 195 290
122 - 144 Fibers O-XXX-L2-XY-F12NS/25T 12 0.81/20.6 12.1/30.8 8.1/20.6 607/2700 180/800 232 345
146 - 216 Fibers O-XXX-L2-XY-F12NS/25T 18 0.81/20.6 12.1/30.8 8.1/20.6 607/2700 180/800 220 327
218 - 288 Fibers O-XXX-L2-XY-F12NS/25T 24 0.90/22.9 13.6/34.4 9.0/22.9 607/2700 180/800 272 404
Singlemode/Multimode O-XXX-L2-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Composite (4-288 Fibers)
*Other jacket/armor configurations available upon request.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP CFR 1755.902 RD Telecommunications Program Listed
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Outside Plant Arid-Core® Mini Stranded Loose Tube CableArmored
Jacket/Armor Combinations for Buried/Underground/Lashed Aerial Applications • Very small 2.0 mm buffer tubes improve kink resistance and facilitate route management in closures • Lightweight, small design is installer-preferred due to ease of handling • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Smaller form factor cable can be utilized for tight duct spaces • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ Single Armor 2 - 72 Fibers O-XXX-LA-XY-FZZNS/20T 6 0.43/10.8 6.4/16.2 4.3/10.8 607/2700 180/800 79 117 74 - 96 Fibers
O-XXX-LA-XY-FZZNS/20T 8 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 92 137
98 - 120 Fibers O-XXX-LA-XY-FZZNS/20T 10 0.52/13.1 7.8/19.7 5.2/13.1 607/2700 180/800 108 160
122 - 144 Fibers O-XXX-LA-XY-FZZNS/20T 12 0.58/14.6 8.6/22.0 5.8/14.6 607/2700 180/800 134 200
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2, Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Mini-Diameter Stranded Loose Tube Cable(72 Fiber Armored Version Shown)
PE Outer JacketSteel Tape ArmoringWater Swellable Tape2.0 mm Gel Filled Buffer TubesWater Blocking GelDielectric Strength Member
Strength Elements
250 Micron Fiber
BinderRipcord (2)
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F20
Arid-Core Mini Stranded Loose TubeNon-Armored, All-Dielectric Cable(72 Fiber Version Shown)
PE Outer JacketWater Swellable Tape2.0 mm Gel Filled Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
BinderRipcord (1)Binder
For Buried/Underground/Lashed Aerial Applications • Lightweight, small design is installer-preferred due to ease of handling • Smaller form factor cable which can be utilized for tight duct space requirements • Small and flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitates route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Specifications are subject to change without notice.
Outside Plant Arid-Core® Mini Stranded Loose Tube CableNon-Armored, All-Dielectric
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ 2 - 72 Fibers O-XXX-LN-XY-F12NS/20T 6 0.37/9.5 5.6/14.3 3.7/9.5 607/2700 180/800 48 72 74 - 96 Fibers
O-XXX-LN-XY-F12NS/20T 8 0.41/10.5 6.2/15.7 4.1/10.5 607/2700 180/800 58 86
98 - 120 Fibers O-XXX-LN-XY-F12NS/20T 10 0.46/11.8 6.9/17.6 4.6/11.8 607/2700 180/800 71 106
122 - 144 Fibers O-XXX-LN-XY-F12NS/20T 12 0.52/13.3 7.8/19.9 5.2/13.3 607/2700 180/800 92 138
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
LSZH Arid Core Mini Stranded Loose TubeArmored Cable(72 Fiber Version Shown)
LSZH Outer JacketSteel Tape ArmoringWater Swellable Tape2.0 mm Gel Filled Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
Ripcord (1)Binder
For Indoor/Outdoor Applications that Require a LSZH Rating • Helps eliminate transition splicing at the building entrance • Lightweight, small design is installer-preferred due to ease of handling • Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management • UV-resistant jacket suitable for use outdoors • Corrugated steel armor is strong yet flexible providing additional crush and rodent protection
Specifications are subject to change without notice.
Indoor/Outdoor LSZH Arid-Core® Mini Stranded Loose Tube CableLow-Smoke Zero-Halogen, Armored
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ 2 - 72 Fibers Z-XXX-LA-XY-F12BK/20G 6 0.48/12.3 7.3/18.5 4.8/12.3 607/2700 180/800 123 183 74 - 96 Fibers
Z-XXX-LA-XY-F12BK/20G 8 0.54/13.6 8.0/20.4 5.4/13.6 607/2700 180/800 143 213
98 - 120 Fibers Z-XXX-LA-XY-F12BK/20G 10 0.58/14.6 8.6/21.9 5.8/14.6 607/2700 180/800 166 248
122 - 144 Fibers Z-XXX-LA-XY-F12BK/20G 12 0.64/16.1 9.5/24.2 6.4/16.1 607/2700 180/800 201 300
Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(ETL)
Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F22
LSZH Mini Stranded Loose TubeNon-Armored, All-Dielectric Cable(72 Fiber Version Shown)
LSZH Outer JacketWater Swellable Tape2.0 mm Gel Filled Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fibers
BinderRipcord (1)
For Indoor/Outdoor Applications that Require a LSZH Rating • Helps eliminate transition splicing at the building entrance • Lightweight, small design is installer-preferred due to ease of handling • Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management • UV-resistant jacket suitable for use outdoors
Specifications are subject to change without notice.
Indoor/Outdoor LSZH Mini Stranded Loose Tube CableLow-Smoke Zero-Halogen, Non-Armored, All-Dielectric
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Single Jacket/ 2 - 72 Fibers Z-XXX-LN-XY-F12BK/20G 6 0.43/11.0 6.5/16.5 4.3/11.0 607/2700 180/800 85 127 74 - 96 Fibers
Z-XXX-LN-XY-F12BK/20G 8 0.47/12.0 7.1/18.0 4.7/12.0 607/2700 180/800 101 151
98 - 120 Fibers Z-XXX-LN-XY-F12BK/20G 10 0.52/13.3 7.8/19.9 5.2/13.3 607/2700 180/800 123 183
122 - 144 Fibers Z-XXX-LN-XY-F12BK/20G 12 0.58/14.7 8.7/22.0 5.8/14.7 607/2700 180/800 151 225
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(ETL)
Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Outside Plant Stranded Loose Tube CableHigh Density Loose Tube
For Buried/Underground/Aerial Applications • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Flexible buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures • Eliminates the need for ribbonized fibers by giving you a compact cable with up to 576 loose fibers
Specifications are subject to change without notice.
All-Dielectric High DensityLoose Tube Fiber Cable(432 Fiber Version Shown)
PE Outer JacketStrength Elements
3.5 mm Gel FilledBuffer Tube
Dielectric Strength MemberFiber Binder ThreadsWater Swellable Tape
250 Micron Optical Fibers
Ripcord (1)
SubunitDetail
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Armored 290-432 Fibers O-XXX-LA-XY-F24NS 18 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 241 358
434-576 Fibers O-XXX-LA-XY-F24NS 24 1.03/26.2 15.4/39.2 10.3/26.2 607/2700 180/800 310 461
All Dielectric 290-432 Fibers O-XXX-LN-XY-F24NS 18 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 173 258
434-576 Fibers O-XXX-LN-XY-F24NS 24 0.98/24.8 14.6/37.2 9.8/24.8 607/2700 180/800 233 347
Double Jacketed Single Armored O-XXX-L2-XY-F24NS 18 1.02/25.9 15.3/38.9 10.2/25.9 607/2700 180/800 337 501 290-432 Fibers
434-576 Fibers O-XXX-L2-XY-F24NS 24 1.15/29.2 17.3/43.8 11.5/29.2 607/2700 180/800 423 630
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression (dielectric) 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Compression (armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Product Type/ Catalog Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number
Sub Outer Diameter Loaded Unloaded Short Term Long Term l bs/ kg/
Units inch/mm
inch/cm lbs/newtons kft km kft km
Single Jacket S-XXX-LN-XY-F12NS/NFB 5 0.46/11.8 7.0/17.7 4.6/11.8 960/4270 775/3447 66 99
2-60 Fibers
ADSS Short Span Loose Tube CableAll-Dielectric, Self-Supporting (ADSS) Aerial Design
For Aerial Long Haul and Metro Applications • Small cable diameter and bend radius for lightweight and ease of handling and installation • Designed for aerial spans requiring a self-supporting, non-messengered product • Single Medium Density Polyethylene (MDPE) jacket for fast convenient cable preparation • Fully qualified in accordance with Telcordia Technologies, EIA/TIA and IEEE Standards
Custom Sag & Tension Tables are available upon request.
Specifications are subject to change without notice.
ADSS Double Jacket Loose TubeAll-Dielectric Cable(60 Fiber Version Shown)
PE Outer Jacket
Aramid Strength Elements
3.0mm Gel-Filled Buffer Tube
Dielectric Strength Member
Water Swellable Tape
Ripcord (1)
Binder
250 Micron Fibers
Other ADSS designs are available upon request.
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F24
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Figure-8 Armored Cable(60 Fiber Version Shown)
MPDE Outer JacketStranded 0.25” Galvanized Steel Messenger
Steel Tape Armoring
BinderWater Swellable Tape
2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube Armored
For Aerial Applications • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Uses standard figure-8 cable hardware and installation practices • 100% gel-free stranded loose tube cable reduces cable prep time • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Minimum Bend Radius Weight Product Type/ Catalog Buffer Cable OD Cable Height Messenger Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm Jacket. OD inch/cm inch/cm kft km
Figure-8 Armored 2 - 60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.89/22.5 0.33/8.3 7.0/17.8 4.7/11.9 230 342 25D
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
For Aerial Applications • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Uses standard figure-8 cable hardware and installation practices • 100% gel-free stranded loose tube cable reduces cable prep time • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Figure-8 Self-SupportingNon-Armored Cable(60 Fiber Version Shown)
MDPE Outer Jacket
Stranded 0.25” Flooded Steel Messenger
Water Swellable TapeBinderStrength Elements2.5 mm Gel-Free Buffer Tube
Dielectric Strength Member
250 Micron Fiber
Ripcord
Binder
\ Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Buffer Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/mm inch/cm inch/cm kft km
Figure-8 Non-Armored 2 - 60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.85/21.7 0.33/8.3 16.5/42.0 8.2/21.0 200 299 25D
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube Non-Armored
Specifications are subject to change without notice.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F26
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Figure-8 Armored Cable(72 Fiber Version Shown)
MPDE Outer JacketStranded 0.25” Galvanized Steel Messenger
Steel Tape Armoring
BinderWater Swellable Tape
3.0 mm Gel Filled Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube Armored
For Aerial Applications • Figure-8 cable design allows easy, one-step installation resulting in cost savings • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection •Uses standard figure-8 cable hardware and installation practices
Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km
Figure-8 Armored 2 - 60 Fibers M-XXX-LA-XY-F12NS 5 0.51/13.0 0.95/24.2 0.35/8.9 7.7/19.4 5.1/13.0 251 373
62 - 72 Fibers M-XXX-LA-XY-F12NS 6 0.55/14.0 0.99/25.1 0.35/8.9 8.2/20.9 5.5/14.0 267 397
74 - 144 Fibers M-XXX-LA-XY-F12NS 12 0.79/20.2 1.24/31.4 0.35/8.9 11.9/30.3 7.9/20.2 372 554
146 - 216 Fibers M-XXX-LA-XY-F12NS 18 0.79/20.2 1.24/31.4 0.35/8.9 11.9/30.3 7.9/20.2 357 531
218-288 Fibers M-XXX-LA-XY-F12NS 24 0.91/23.2 1.35/34.4 0.35/8.9 13.7/34.7 9.1/23.2 424 633
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Figure-8 Non-Armored Cable(72 Fiber Version Shown)
MDPE Outer Jacket
Stranded 0.25” Galvanized Steel Messenger
Water Swellable TapeBinderStrength Elements3.0 mm Gel-Filled Buffer Tube
Dielectric Strength Member
250 Micron Fiber
BinderRipcordBinder
Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km
Figure-8 Non-Armored 2 - 60 Fibers M-XXX-LN-XY-F12NS 5 0.46/11.6 0.90/22.8 0.35/8.9 6.8/17.4 4.6/11.6 214 318
2 - 72 Fibers M-XXX-LN-XY-F12NS 6 0.50/12.6 0.94/23.8 0.35/8.9 7.4/18.9 5.0/12.6 227 338
74 - 144 Fibers M-XXX-LN-XY-F12NS 12 0.74/18.8 1.18/30.0 0.35/8.9 11.1/28.2 7.4/18.8 313 466
146 - 216 Fibers M-XXX-LN-XY-F12NS 18 0.74/18.8 1.18/30.0 0.35/8.9 11.1/28.2 7.4/18.8 298 443
218-288 Fibers M-XXX-LN-XY-F12NS 24 0.86/21.8 1.30/33.0 0.35/8.9 12.9/32.7 8.6/21.8 349 520
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube Non-Armored
Specifications are subject to change without notice.
For Aerial Applications • Figure-8 cable design allows easy, one-step installation resulting in cost savings • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Standard color-coding on fibers and buffer tubes helps ease installation • All buffer tubes are constructed to a nominal OD of 3mm reducing the number of tools required in the field •Uses standard figure-8 cable hardware and installation practices
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F28
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Figure-8 Armored Cable(60 Fiber Version Shown)
MPDE Outer JacketStranded 3/16” Galvanized Steel Messenger
Steel Tape Armoring
BinderWater Swellable Tape
2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube Armored
For Aerial Applications • 100% gel-free stranded loose tube cable reduces cable prep time • Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures
Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km
Figure-8 Armored 2 - 60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.83/21.1 0.27/6.9 7.0/17.8 4.7/11.9 180 267 25D/188
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140°F (+70°C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Specifications are subject to change without notice.
Figure-8 Non-Armored Cable(60 Fiber Version Shown)
MPDE Outer JacketStranded 3/16” Galvanized Steel Messenger
Binder
Water Swellable Tape
2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube, Non-Armored
For Aerial Applications • 100% gel-free stranded loose tube cable reduces cable prep time • Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km
Figure-8 Non-Armored 2 - 60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.78/19.7 0.27/6.9 6.2/15.8 4.1/10.5 146 217 25D/188
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
F30
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Specifications are subject to change without notice.
Figure-8 Armored Cable(60 Fiber Version Shown)
MPDE Outer Jacket0.109” Galvanized Steel Messenger
Steel Tape Armoring
Binder
Water Swellable Tape
2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube, Armored
For Aerial Applications • 100% gel-free stranded loose tube cable reduces cable prep time • Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures
Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km
Figure-8 Armored 2 - 60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.75/19.2 0.20/5.0 7.0/17.8 4.7/11.9 124 185 25D/109
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Figure-8 Non-Armored Cable(60 Fiber Version Shown)
MPDE Outer Jacket0.109” Galvanized Steel Messenger
Binder
Water Swellable Tape
2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
250 Micron Fibers
Strength Elements
Ripcord (1)
Binder
Outside Plant Self-Supporting Figure-8 CableMessengered Stranded Loose Tube, Non-Armored
For Aerial Applications • 100% gel free stranded loose tube cable reduces cable prep time • Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative • Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km
Figure-8 Non-Armored 2 - 60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.70/17.8 0.20/5.0 6.2/15.8 4.1/10.5 90 134 25D/109
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
F32
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Riser-Rated Indoor/OutdoorStranded Loose Tube Cable(72 Fiber Version Shown)
PVC Outer JacketWater Swellable Tape2.5 mm Gel Free Buffer Tube
Dielectric Strength Member
Strength Element
250 Micron Fiber
Binder
Ripcord
Binder
Indoor/Outdoor Stranded Loose Tube CableRiser-Rated
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Single Jacket 2 - 60 Fibers
R-XXX-LN-XY-F12BK/25D 5 0.45/11.5 6.8/17.3 4.5/11.5 607/2700 180/800 79 118
62 - 72 Fibers R-XXX-LN-XY-F12BK/25D 6 0.47/11.9 7.1/17.9 4.7/11.9 607/2700 180/800 85 127
74 - 96 Fibers R-XXX-LN-XY-F12BK/25D 8 0.53/13.5 8.0/20.3 5.3/13.5 607/2700 180/800 109 161
98 - 120 Fibers R-XXX-LN-XY-F12BK/25D 10 0.59/15.1 8.9/22.6 5.9/15.1 607/2700 180/800 130 193
122 - 144 Fibers R-XXX-LN-XY-F12BK/25D 12 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 176 262
146 - 216 Fibers R-XXX-LN-XY-F12BK/25D 18 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 162 240
218 - 288 Fibers R-XXX-LN-XY-F12BK/25D 24 0.79/20.2 11.9/30.2 7.9/20.2 607/2700 180/800 208 309
Singlemode/Multimode R-XXX-LN-XY-F12BK/25D/AAaaa/BBbbb Refer to above specifications.
Composite (4-288 Fibers)
For Indoor/Outdoor Applications that Require a Riser Rating• All meet critical NEC/CEC riser (OFNR) safety standards, eliminating the need for splice point at building entrance• 100% gel free stranded loose tube cable reduces cable prep time• Lightweight, small design is installer-preferred due to ease of handling• Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures
Specifications are subject to change without notice.
Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(ETL)
Flame Test Standard UL-1666
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable(72 Fiber Version Shown)
Plenum-Rated Outer JacketWater Swellable Tape2.5mm Gel Free Buffer Tubes
Dielectric Strength Member
Strength Elements
250 Micron Fiber
Binder
Ripcord (1)
Binder
Indoor/Outdoor Stranded Loose Tube CablePlenum-Rated
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Single Jacket 2 - 60 Fibers P-XXX-LN-XY-F12BK/25D 5 0.38/9.7 5.7/14.6 3.8/9.7 600/2700 180/800 64 96
61 - 72 Fibers P-XXX-LN-XY-F12BK/25D 6 0.40/10.1 6.0/15.2 4.0/10.1 600/2700 180/800 71 105
74 - 96 Fibers P-XXX-LN-XY-F12BK/25D 8 0.46/11.7 6.9/17.5 4.6/11.7 600/2700 180/800 95 142
98 - 120 Fibers P-XXX-LN-XY-F12BK/25D 10 0.52/13.3 7.8/19.9 5.2/13.3 600/2700 180/800 124 185
122 - 144 Fibers P-XXX-LN-XY-F12BK/25D 12 0.60/15.3 9.1/23.0 6.0/15.3 600/2700 180/800 168 250
Singlemode/Multimode P-XXX-LN-CM-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Composite (4-144 Fibers)
For Indoor/Outdoor Applications that Require a Plenum Rating • Combines application spaces of building interconnect and plenum in a campus environment • Dielectric design is lightweight, easy to access and does not require grounding • 100% gel-free stranded loose tube cable reduces cable prep time • Water blocking prevents moisture migration • Temperature range is fully outside plant rated
Specifications are subject to change without notice.
Flame Test Specifications Flame Test Listing NEC Type OFNP (ETL) and c(ETL)
Flame Test Standard NFPA-262
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F34
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Riser-Rated Indoor/OutdoorStranded Loose Tube Cable(72 Fiber Version Shown)
Riser-Rated Outer JacketInterlocking Aluminum ArmorRiser-Rated Inner JacketStrength ElementsWater Swellable TapeDielectric Strength Member
250 Micron Fiber
Binder
2.5 mm Gel Free Buffer Tubes
Ripcord(1)
Indoor/Outdoor FiberGuardTM Stranded Loose Tube CableRiser-Rated
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 60 Fibers R-XXX-LZ-XY-FZZBK/25D 5 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 215 320
62 - 72 Fibers R-XXX-LZ-XY-FZZBK/25D 6 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 221 328
74 - 96 Fibers R-XXX-LZ-XY-FZZBK/25D 8 0.86/21.7 17.1/43.5 12.0/30.4 300/1335 90/400 254 378
98 - 120 Fibers R-XXX-LZ-XY-FZZBK/25D 10 0.91/23.0 18.1/46.0 12.7/32.2 300/1335 90/400 285 424
122 - 144 Fibers R-XXX-LZ-XY-FZZBK/25D 12 1.01/25.5 20.1/51.1 14.1/35.7 300/1335 90/400 329 489
146 - 216 Fibers R-XXX-LZ-XY-FZZBK/25D 18 1.06/26.8 21.1/53.6 14.8/37.5 300/1335 90/400 323 481
218 - 288 Fibers R-XXX-LZ-XY-FZZBK/25D 24 1.11/28.1 22.1/56.2 15.5/39.3 300/1335 90/400 378 563
Singlemode/Multimode R-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications.
Composite (4-288 Fibers)
For Indoor/Outdoor Applications that Require a Riser Rating• Cables are protected with an interlocking armor to shield against damage• Well suited for construction and renovations, heavy industry and high security area applications• Aluminum interlocking armor with overall jacket• NEC/CEC compliant• Outstanding mechanical protection for sensitive cables combined with excellent flexibility
Flame Test Specifications Flame Test Listing NEC Type OFCR (ETL) and c(ETL)
Flame Test Standard UL-1666
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 483 lbf/in (85 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 25 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Specifications are subject to change without notice.
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Plenum-Rated Indoor/OutdoorStranded Loose Tube Cable(72 Fiber Version Shown)
Plenum-Rated Outer JacketInterlocking Aluminum ArmorPlenum-Rated Inner JacketStrength ElementsWater Swellable TapeDielectric Strength Member
250 Micron Fiber
Binder
2.5 mm Gel Free Buffer Tubes
Ripcord(1)
Indoor/Outdoor FiberGuardTM Stranded Loose Tube CablePlenum-Rated
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 60 Fibers P-XXX-LZ-XY-FZZBK/25D 5 0.71/17.9 14.1/35.8 9.9/25.1 300/1335 90/400 192 286
62 - 72 Fibers P-XXX-LZ-XY-FZZBK/25D 6 0.71/17.9 14.1/35.8 9.9/25.1 300/1335 90/400 199 296
74 - 96 Fibers P-XXX-LZ-XY-FZZBK/25D 8 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 245 365
98 - 120 Fibers P-XXX-LZ-XY-FZZBK/25D 10 0.86/21.7 17.1/43.5 12.0/30.4 300/1335 90/400 285 425
122 - 144 Fibers P-XXX-LZ-XY-FZZBK/25D 12 0.96/24.3 19.1/48.5 13.4/34.0 300/1335 90/400 330 491
Singlemode/Multimode P-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications.
Composite (4-288 Fibers)
For Indoor/Outdoor Applications that Require a Plenum Rating• Cables are protected with an interlocking armor to shield against damage• Well suited for construction and renovations, heavy industry and high security area applications• Aluminum interlocking armor with overall jacket• 100% gel-free stranded loose tube cable reduces cable prep time• Outstanding mechanical protection for sensitive cables combined with excellent flexibility
Flame Test Specifications Flame Test Listing NEC Type OFCP (ETL) and c(ETL)
Flame Test Standard NFPA-262
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 483 lbf/in (85 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 25 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip N/A N/A
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-24 repeat color sequence with tracer stripe
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Specifications are subject to change without notice.
F36
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Outside Plant Central Tube CableArmored and All-Dielectric Designs
For Buried/Underground/Aerial Applications •Robust constructions offer excellent protection of fibers • Provides easy access to the fibers • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort
Central Tube Armored Cable(24 Fiber Version Shown)
Steel RSM (2)Ripcord for Armor Access (2)PE Outer JacketGel4.0 mm Buffer TubeFiber Binder Thread250 Micron FibersSteel ArmorRipcord for Jacket Access (2)
Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Armored O-XXX-CA-XY-F12NS 2 0.43/11.0 6.5/16.5 4.3/11.0 607/2700 180/800 91 135 2-24 Fibers, 4mm Tube
26-48 Fibers, 6mm Tube O-XXX-CA-XY-F12NS 4 0.51/13.0 7.7/19.5 5.1/13.0 607/2700 180/800 118 176
50-96 Fibers, 8mm Tube O-XXX-CA-XY-F12NS 8 0.59/15.0 8.9/22.5 5.9/15.0 607/2700 180/800 148 220
All-Dielectric O-XXX-CN-XY-F12NS 2 0.40/10.1 5.9/15.1 4.0/10.1 607/2700 180/800 63 94 2-24 Fibers, 4mm Tube
26-48 Fibers, 6mm Tube O-XXX-CN-XY-F12NS 4 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 86 128
50-96 Fibers, 8mm Tube O-XXX-CN-XY-F12NS 8 0.55/14.1 8.3/21.1 5.5/14.1 607/2700 180/800 110 164
Singlemode/Multimode O-XXX-CA-CM-F12NS/AAAaa/BBbbb Refer to above specifications. Composite (4-96 Fibers) O-XXX-CN-CM-F12NS/AAaaa/BBbbb (Tube size will vary depending on fiber count/configuration.)
Central Tube Non-Armored All-Dielectric Cable(36 Fiber All-Dielectric Version Shown)
Rigid RSM (2)
PE Outer JacketWater-Blocking TapeGel6.0 mm Buffer TubeFiber Binder Threads250 Micron FibersRipcord for Jacket Access (2)
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression (Dielectric) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +70° (+140° C) FOTP-81; IEC 60794-102, Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Indoor/Outdoor Central Tube CablesRiser-Rated
For Indoor/Outdoor Applications that Require a Riser Rating • All meet critical NEC/CEC riser (OFNR) safety standards eliminating the need for splice point at building entrance • Arid-Core® water blocking technology helps protect fibers from moisture • Standard color-coding on fibers helps ease installation • Robust constructions offer excellent protection of fibers
Indoor/Outdoor Central Tube Cable(24 Fiber Version Shown)
Rigid RSM (2)
PVC Outer Jacket
Flexible Strength Elements
Gel
4.0mm Buffer Tube
250 Micron Fibers
Fiber Binder Threads
Ripcord for Jacket Access (2)
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Single Jacket 2-24 Fibers, 4mm Tube R-XXX-CN-XY-F12BK 2 0.40/10.1 5.9/15.1 4.0/10.1 607/2700 180/800 87 129
Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(ETL)
Flame Test Standard UL-1666
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140° F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F38
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend Insensitive, Singlemode Fiber* For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
*CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Drop Armored Cable(12 fiber version shown)
MDPE Outer JacketSteel ArmorFiberglass Strength Elements3.0mm Buffer TubeAramid Strength ElementsGel250 Micron Fibers
Outside Plant Drop CableArmored Design
For Buried/Underground/Aerial Applications • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Small, lightweight cable increases ease of installation, routing and termination (no preferential bend) • Cost effective, low fiber count cable for outside plant applications • Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Armored
O-XXX-DA-XY-F12NS 1 0.32/8.1 4.8/12.2 3.2/8.1 300/1334 90/400 47 70 1-12 Fibers
Singlemode/Multimode O-XXX-DA-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Composite (4-12 Fibers)
*This design is also available with a ripcord for applications where mid-span access is important (O-XXX-DA-XY-F12NS/BP)
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
F39
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F40
All-Dielectric Drop Cable(12 fiber version shown)
PE Outer Jacket
Rigid RSM (2)
Strength Elements
3.0 mm Buffer Tube
Gel
250 Micron Fibers
Outside Plant Drop CableAll-Dielectric Design
Specifications are subject to change without notice.
For Buried/Underground/Aerial Applications • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Small, lightweight cable increases ease of installation, routing and termination • Cost effective, low fiber count cable for outside plant applications • An outstanding choice when space is at a premium • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, 6F 62.5µm, FDDI Grade Multimode Fiber Matched-Clad Singlemode Fiber 5M LazrSPEED® 150, 50µm, Multimode Fiber 8F Bend-Insensitive, Singlemode Fiber* For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
*CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002
Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
All-Dielectric O-XXX-DN-XY-F12NS 1 0.34/8.7 5.1/13.0 3.4/8.7 300/1334 90/400 46 691 - 12 Fibers
Singlemode/Multimode O-XXX-DN-CM-F12NS/AAaaa/BBbbb Refer to above specifications.Composite (4-12 Fibers)
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, 6F 62.5µm, FDDI Grade Multimode Fiber Matched-Clad Singlemode Fiber 5M LazrSPEED® 150, 50µm, Multimode Fiber 8F Bend-Insensitive, Singlemode Fiber* For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
*CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter
Figure-8 Drop Cable(6 fiber version shown)
Low Density Polyethylene Outer Jacket
0.109” Solid Steel Messenger
Strength Elements
2.5 mm Gel Filled Buffer Tube
250 Micron Fibers
Rigid Strength Elements
Ripcord (1)
Self-Support Non-Armor Figure-8 Outdoor Drop Cable1 - 6 Fiber Arid-Core Construction
Specifications are subject to change without notice.
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
For Aerial Applications •Cost effective, low fiber count cable for outside plant applications • Figure-8 cable designed for extended span capability •Small, very flexible cable allowing for increased ease of installation, routing and termination •The legs can be easily separated as needed • Fiber leg was designed to function as a self-sufficient cable once separated from the messenger
Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop
M-XXX-MN-XY-FZZNS/ 0.17/4.3 0.42/10.7 0.20/5.1 3.0/7.7 2.0/5.1 300/1334 90/400 52 77 1 - 6 Fibers 25G/109
F41
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Figure-8 Drop Cable(2 fiber version shown)
MDPE Outer Jacket
0.083” Messenger Wire
Strength Elements
Ripcord (1)
4.0 mm Buffer Tube
Gel
250 Micron Fibers
Outside Plant Self-Supporting Figure-8 Drop Cable1 - 12 Fiber Arid-Core Construction
Specifications are subject to change without notice.
For Aerial Applications •Small, lightweight cable allowing for increased ease of installation, routing and termination • Cost effective, low fiber count cable for outside plant applications • Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip • Solid steel messenger member for simplified aerial applications • Flexible design allows ease of routing and placement • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, 6F 62.5µm, FDDI Grade Multimode Fiber Matched-Clad Singlemode Fiber 5M LazrSPEED® 150, 50µm, Multimode Fiber 8F Bend-Insensitive, Singlemode Fiber* For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
*CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter
Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop
M-XXX-DN-XY-FZZNS/ 0.13/3.4 0.45/11.5 0.27/6.8 4.0/10.2 2.7/6.8 300/1334 90/400 47 69 1 - 12 Fibers GSM/40T
F42
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, 6F 62.5µm, FDDI Grade Multimode Fiber Matched-Clad Singlemode Fiber 5M LazrSPEED® 150, 50µm, Multimode Fiber 8F Bend-Insensitive, Singlemode Fiber* For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
*CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter
Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop
M-XXX-MN-XY-F12NS/ 0.16/4.0 0.36/9.0 0.15/3.8 2.2/5.6 1.5/3.8 300/1334 90/400 26 39 1 - 12 Fibers CCS
Figure-8 Mini-Drop Cable(6 fiber version shown)
Linear Low DensityPolyethylene Outer Jacket
Solid Steel Messenger
2.5mm Gel Filled Buffer Tube
250 Micron Fibers
Outside Plant Self-Supporting Figure-8 Mini-Drop Cable1 - 6 Fiber Arid-Core Construction Copper Clad Steel Messenger
Specifications are subject to change without notice.
For Underground/Conduit Applications • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort •Small, lightweight cable increases ease of installation, routing and termination • Cost effective, low fiber count cable for outside plant applications • Solid steel messenger member can be used for toning • Flexible design allows ease of routing and placement • Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
F43
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Specifications are subject to change without notice.
For Aerial Applications • All dielectric cable design, which requires no bonding or grounding • Compatible with industry standard hanging hardware • Cost effective, low fiber count cable for outside plant applications • Small, lightweight cable increases ease of installation, routing and termination
Outside Plant All-Dielectric Flat Drop Cable1 - 12 Fiber Arid-Core Construction Aerial Self-Support or Direct Burial
Figure-8 Mini-Drop Cable(12 fiber version shown)
MDPE Outer Jacket
GRP Rods
2.0mm Buffer Tube
250 Micron Fibers
Ripcords (2)
Product Type/ Catalog Cable Outer Cable Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Loaded Unloaded Short Term Long Term lbs/ kg/
inch/mm inch/mm inch/cm inch/cm lbs/N lbs/N kft km All-Dielectric Flat Drop
O-XXX-DF-XY-F12NS 0.32/8.2 0.18/4.5 4.8/12.3 3.2/8.1 300/1334 90/400 28 42 1 - 12 Fibers
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F44
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Specifications are subject to change without notice.
For Underground/Conduit Applications • Incorporated tone wire designed for tone locating when digging • Cost effective, low fiber count cable for outside plant applications • Small, lightweight cable increases ease of installation, routing and termination • Tone wire can be easily separated as needed • Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Outside Plant All-Dielectric Flat Drop Cable1 - 12 Fiber Arid-Core Construction Aerial Self-Support
Figure-8 Mini-Drop Cable(12 fiber version shown)
24-awg Copper Conductor
MDPE Outer Jacket
GRP Rods
2.0mm Buffer Tube
250 Micron Fibers
Ripcords (2)
Product Type/ Catalog Cable Outer Cable Msg. Jkt. Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Outer Dia. Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/mm inch/cm inch/cm lbs/N kft km
All-Dielectric Flat Drop O-XXX-DF-HY-F12NS/ 0.40/10.2 0.18/4.5 0.08/2.0 6.0/15.3 3.2/8.1 300/1334 90/400 38 57 1 - 12 Fibers
XYXXX/1x24AWG
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F ;+70° C FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed
F45
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F46
Specifications are subject to change without notice.
LSZH Indoor/Outdoor CableNon-Armored, All-Dielectric
LSZH All-Dielectric Indoor/Outdoor Cable(12 Fiber, 4.0 mm Tube Version Shown)
FRPE Outer Jacket
Fiberglass Strength Elements
4.0 mm Gel Filled Buffer Tube
250 Micron Fibers
Ripcord
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Single Jacket 1-24 Fibers Z-XXX-DN-XY-F12BK 2 0.33/8.3 4.9/12.5 3.3/8.3 300/1334 90/400 48 72
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
Single Jacket 1-12 Fibers Z-XXX-DN-XY-F12BK/ 1 0.24/6.1 3.6/9.1 2.4/6.1 300/1334 90/400 30 44 20G
For Indoor/Outdoor Drop Applications that Require a LSZH Rating • Black jackets are UV-stable for outdoor use yet meet critical NEC type safety standards – OFNR-LS (ETL) and C(ETL) • Also meets many international flame ratings such as IEC 60332-1, IEC 60332-3, IEC 61034-02, IEC 60754-1, IEC 60754-2 and NES 713 • Riser rating eliminates splice points at the building entrance • Arid-Core® water blocking technology helps protect fibers from moisture • Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment
Flame Test Specifications Flame Test Listing NEC Type OFNR-LS (ETL) and c(ETL)
Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2, IEC 60754-2, IEEE 383
Environmental Specifications Installation Temperature -4° to +158°F (-20° to +70°C)
Operating Temperature -4° to +158°F (-20° to +70°C)
Storage Temperature -4° to +167°F (-20° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze +28° F (-2° C) FOTP-98
Drip +140° F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -4° to +185°F (-20° to +85°C) N/A
Low High Bend -4° to +140°F (-20° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -4° to +158°F (-20° to +70°C) 24 Hours
CommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
ConQuest® Toneable ConduitTM
Installed with Central Tube Fiber Optic Products
Fiber In ConQuest Toneable Conduit Cuts Installation Effort and Costs • High strength 18 gauge copper clad steel tone wire saves installation dollars • Moisture resistant polymer coated tone wire accurately detectable over various depths and lengths • Tone wire embedded in the wall of the HDPE conduit results in easy wire removal • Internally reinforced HDPE wall works with standard conduit connections
Specifications are subject to change without notice.
Other cables and wall sizes may be available upon request. * Weight does not include reel.For more information, please see the Conduit section of this catalog.
Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40
Central Tube O-XXX-CN-XY-F12NS 0.40” 1” SDR 11 or 13.5 265 230 Dielectric Specify Conduit OD, 63 lbs. 11/4” SDR 11 or 13.5 381 326 2 - 24 Fibers Wall Thickness and Color 11/2” SDR 11 or 13.5 477 405 2” SDR 13.5 or SCH 40 593 533
Central Tube O-XXX-CN-XY-F12NS 0.48” 1” SDR 11 or 13.5 273 238Dielectric Specify Conduit OD, 86 lbs. 11/4” SDR 11 or 13.5 389 334 26 - 48 Fibers Wall Thickness and Color 11/2” SDR 11 or 13.5 485 413 2” SDR 13.5 or SCH 40 601 541
Central Tube O-XXX-CN-XY-F12NS 0.55” 1” SDR 11 or 13.5 291 256Dielectric Specify Conduit OD, 110 lbs. 11/4” SDR 11 or 13.5 407 352 50 - 96 Fibers Wall Thickness and Color 11/2” SDR 11 or 13.5 503 431 2” SDR 13.5 or SCH 40 619 559
Central Tube Fiber-In-Conduit(24 Fiber Construction inToneable Conduit Shown)
Copper Clad SteelTone Wire
High-Grade Polyethylene Conduit
Silicon-Based Lubricant
Central Tube Cable
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
ConQuest® Toneable ConduitTM
Pre-Installed with CommScope Dry Loose Tube Fiber Optic Cable
Fiber-In-ConduitAll of CommScope’s fiber cables can be pre-installed in conduit, including the gel free, Dry Loose Tube cable. Available in five different diameters - 3/4”, 1”, 11/4”, 11/2” and 2” and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com.
* Weight does not include reel.Other cables and wall sizes may be available upon request.
Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40
Dry (gel free) D-XXX-LN-XY-F12NS 0.40” 3/4” SDR 11 or 13.5 175 156Loose Tube Specify Conduit OD, Wall 45 lbs. 1” SDR 11 or 13.5 249 214 Dielectric Thickness and Color 11/4” SDR 11 or 13.5 355 2642 - 60 Fibers 11/2” SDR 11 or 13.5 461 389 2” SDR 13.5 or SCH 40 577 517 Dry (gel free) D-XXX-LN-XY-F12NS 0.42” 3/4” SDR 11 or 13.5 179 160 Loose Tube Specify Conduit OD, Wall 49 lbs. 1” SDR 11 or 13.5 253 218 Dielectric Thickness and Color 11/4” SDR 11 or 13.5 369 31462 - 72 Fibers 11/2” SDR 11 or 13.5 465 393 2” SDR 13.5 or SCH 40 581 521
Dry (gel free) D-XXX-LN-XY-F12NS 0.48” 3/4” SDR 11 or 13.5 194 175Loose Tube Specify Conduit OD, Wall 64 lbs. 1” SDR 11 or 13.5 269 233 Dielectric Thickness and Color 11/4” SDR 11 or 13.5 384 32974 - 96 Fibers 11/2” SDR 11 or 13.5 480 408 2” SDR 13.5 or SCH 40 596 536 Dry (gel free) D-XXX-LN-XY-F12NS 0.54” 1” SDR 11 or 13.5 287 252Loose Tube Specify Conduit OD, Wall 83 lbs. 11/4” SDR 11 or 13.5 403 348 Dielectric Thickness and Color 11/2” SDR 11 or 13.5 499 42798 - 120 Fibers 2” SDR 13.5 or SCH 40 615 555
Dry (gel free) D-XXX-LN-XY-F12NS 0.62” 11/4” SDR 11 or 13.5 427 372 Loose Tube Specify Conduit OD, Wall 107 lbs. 11/2” SDR 11 or 13.5 523 451Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 639 579 122 - 144 Fibers Dry (gel free) D-XXX-LN-XY-F12NS 0.62” 11/4” SDR 11 or 13.5 410 355 Loose Tube Specify Conduit OD, Wall 90 lbs. 11/2” SDR 11 or 13.5 506 434Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 622 562146 - 216 Fibers Dry (gel free) D-XXX-LN-XY-F12NS 0.72” 11/4” SDR 11 or 13.5 442 387Loose Tube Specify Conduit OD, Wall 122 lbs. 11/2” SDR 11 or 13.5 538 466 Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 654 594 218 - 288 Fibers
Dry Loose Tube Fiber-In-Conduit(72 Fiber Construction inToneable Conduit Shown)
Copper Clad Steel Tone Wire
High-Grade Polyethylene Conduit
Silicon-Based Lubricant
Dry Loose Tube Cable
Other cables and wall sizes may be available upon request. * Weight does not include reel.
Specifications are subject to change without notice.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F48
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
ConQuest® Toneable ConduitTM
Pre-Installed with CommScope Arid-Core® Fiber Optic Cable
* Weight does not include reel.Other cables and wall sizes may be available upon request.
Specifications are subject to change without notice.
Fiber-In-ConQuest Toneable Conduit Cuts Installation Effort and CostsAll of CommScope’s fiber cables can be pre-installed in conduit, including the Arid-Core Loose Tube cable. Available in five different diameters - 3/4”, 1”, 11/4”, 11/2” and 2” and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com.
Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40
Arid-Core O-XXX-LN-XY-F12NS/25T 0.40” 3/4” SDR 11 or 13.5 178 159Loose Tube Specify Conduit OD, Wall 48 lbs. 1” SDR 11 or 13.5 252 217 Dielectric Thickness and Color 11/4” SDR 11 or 13.5 368 3132 - 60 Fibers 11/2” SDR 11 or 13.5 464 392 2” SDR 13.5 or SCH 40 580 520 Arid-Core O-XXX-LN-XY-F12NS/25T 0.42” 3/4” SDR 11 or 13.5 182 163 Loose Tube Specify Conduit OD, Wall 52 lbs. 1” SDR 11 or 13.5 256 221 Dielectric Thickness and Color 11/4” SDR 11 or 13.5 372 32762 - 72 Fibers 11/2” SDR 11 or 13.5 468 396 2” SDR 13.5 or SCH 40 584 524
Arid-Core O-XXX-LN-XY-F12NS/25T 0.48” 3/4” SDR 11 or 1.35 200 180 Loose Tube Specify Conduit OD, Wall 69 lbs. 1” SDR 11 or 13.5 273 268Dielectric Thickness and Color 11/4” SDR 11 or 13.5 389 334 74 - 96 Fibers 11/2” SDR 11 or 13.5 485 413 2” SDR 13.5 or SCH 40 578 518
Arid-Core O-XXX-LN-XY-F12NS/25T 0.54” 1” SDR 11 or 13.5 293 258 Loose Tube Specify Conduit OD, Wall 89 lbs. 11/4” SDR 11 or 13.5 409 382Dielectric Thickness and Color 11/2” SDR 11 or 13.5 505 461 98 - 120 Fibers 2” SDR 13.5 or SCH 40 649 561
Arid-Core O-XXX-LN-XY-F12NS/25T 0.62” 11/4” SDR 11 or 13.5 434 379 Loose Tube Specify Conduit OD, Wall 114 lbs. 11/2” SDR 11 or 13.5 530 458Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 646 586 122 - 144 Fibers
Arid-Core O-XXX-LN-XY-F12NS/25T 0.62” 11/4” SDR 11 or 13.5 422 367 Loose Tube Specify Conduit OD, Wall 102 lbs. 11/2” SDR 11 or 13.5 518 446Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 634 574 146 - 216 Fibers
Arid-Core O-XXX-LN-XY-F12NS/25T 0.72” 11/4” SDR11 or 13.5 458 403 Loose Tube Specify Conduit OD, Wall 138 lbs. 11/2” SDR 11 or 13.5 554 482 Dielectric Thickness and Color 2” SDR 13.5 or SCH 40 670 610218 - 288 Fibers
Arid-Core Loose Tube Fiber-In-Conduit(72 Fiber Construction inToneable Conduit Shown)
Copper Clad SteelTone Wire
High-Grade Polyethylene Conduit
Silicon-Based Lubricant
Arid-Core Loose Tube Cable
Other cables and wall sizes may be available upon request. * Weight does not include reel.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Drawings are not to scaleSpecifications are subject to change without notice
ConQuest® ConduitPre-Installed with CommScope Fiber Drop Cable
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber
For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
6F 62.5µm, FDDI Grade Multimode Fiber5M LaserCore® 150, 50µm, Multimode Fiber
High-GradePolyethylene Conduit
Figure-8 Fiber Drop Cable In Conduit
Silicon-BasedLubricant
MessengeredFiber DropCable
Solid Steel MessengeredFiber Drop In ConQuest Conduit(6 Fiber Construction Shown)
All-Dielectric Flat DropCable in ConQuest Conduit(6 Fiber Construction Shown)
Toneable Flat DropCable in ConQuest Conduit(6 Fiber Construction Shown)
Fiber-In-ConduitAll of CommScope’s fiber cables can be pre-installed in conduit, including the Fiber Drop cables. Available in 1/2” or 3/4” and two differ-ent wall thicknesses - SDR 11 or SDR 13.5. For more information or specifications on Fiber Optic cables, please visit our website atwww.commscope.com.
Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5
Fiber Drop M-XXX-MN-XY-FZZNS/CCS 0.16” x 0.31” ½” SDR 11 or 13.5 112 98 Messengered (Solid Steel Construction) 27 lbs. ¾” 157 138 1 - 6 Fibers Specify Conduit OD, Wall Thickness and Color
All-Dielectric Flat Drop Cable In Conduit
Toneable Flat Drop Cable In Conduit
Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Flat Drop O-XXX-DF-XY-FZZNS 0.18” x 0.32” ½” SDR 11 or 13.5 115 101 1 - 12 Fibers Specify Conduit OD, 30 lbs. ¾” 160 141 Wall Thickness and Color
High-GradePolyethylene Conduit
High-GradePolyethylene Conduit
Silicon-BasedLubricant
Silicon-BasedLubricant
Flat Drop Cable ToneableFlat Drop Cable
NOTE: The solid or stranded steel messengers can be used to pull the cable during installation, and for locating after burial.
*Other size conduits may be available upon request.
*Other size conduits may be available upon request.
* Weight does not include reel.
* Weight does not include reel.
F50
Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5
ToneableFlat Drop O-XXX-DF-HY-FZZNS/XYZZZ/ 0.18” x 0.40” ¾” SDR 11 or 13.5 168 149
1 - 12 Fibers 1X12AWG 38 lbs. 1” SDR 11 or 13.6 242 207
Specify Conduit OD, Wall Thickness and Color
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Arid-Core ConstructionFiber Coax Hybrid Cable(12 Fiber Version Shown)
LDPE Jacket
BrightWire Aluminum Braid
Anti-Corrosion Tape
BrightWire Aluminum Braid
Anti-Corrosion Tape
18 AWG Copper Clad Steel
Dielectric
Fiberglass Strength Elements
4.0mm Buffer Tube
Gel
250 Micron Fibers
Ripcord
CommScope Hybrid CableFiber/6 Series Drop Cable (BrightWire®)
Specifications are subject to change without notice.
Features & Benefits • The BrightWire drop cable leg is designed to carry video • The optical leg is designed to carry voice and data • Only a single installation is required • Small, very flexible cable allowing for increased ease of installation, routing and termination • The legs can be easily separated as needed
Product Type/ Catalog Cable Outer Cable Component Sub Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Units Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm lbs/N lbs/N kft km
1 - 12 Fibers O-XXX-DN-HY-F12NS/ 0.26/6.6 0.61/15.4 0.30/7.5 1 3.9/9.9 2.6/6.6 300/1334 90/400 78 116 40G/XYXXX/F6SSBW
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Jacket Color: Black Medium Density Polyethylene
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Product Type/ Catalog Cable Outer Cable Messenger Copper Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Comp./ Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm Buffer Tubes inch/cm inch/cm lbs/N lbs/N kft km
1 - 12 Fibers M-XXX-DN-HY-F12NS/ 0.26/6.6 0.79/20.1 0.13/3.4 1/1 3.9/9.9 2.6/6.6 300/1334 90/400 101 150 XYXXX/40T/F6SSBW/
GSM
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Jacket Color: Black Linear Low Density Polyethylene
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-110-717-2002
Arid-Core ConstructionSelf-Supporting Hybrid Cable(12 Fiber Version with Messenger Shown)
Galvanized Steel Messenger
LDPE Jacket
BrightWire Aluminum Braid
Anti-Corrosion Tape
BrightWire Aluminum Braid
Anti-Corrosion Tape
0.0403 CU/Steel
Dielectric
4.0mm Buffer Tube
Strength Elements
Gel
Ripcord (1)
250 Micron Fibers
CommScope Self-Support Figure-8 Hybrid CableFiber/6 Series Drop Cable (BrightWire®)
Features & Benefits • The BrightWire drop cable leg is designed to carry video • The optical leg is designed to carry voice and data • Only a single installation is required • Small, very flexible cable allowing for increased ease of installation, routing and termination • The legs can be easily separated as needed
Specifications are subject to change without notice.
F52
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Hybrid Single Jacket Outdoor CableArmored
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 48 Fibers O-XXX-LA-HY-FZZNS/ 5 0.50/12.7 7.5/19.0 5.0/12.7 607/2700 180/800 95 141 1 Pair XYXXX/1X22UTP
50 - 60 Fibers O-XXX-LA-HY-FZZNS/ 6 0.54/13.7 8.1/20.5 5.4/13.7 607/2700 180/800 110 164 1 Pair XYXXX/1X22UTP
62 - 84 Fibers O-XXX-LA-HY-FZZNS/ 8 0.62/15.7 9.3/23.6 6.2/15.7 607/2700 180/800 141 210 1 Pair XYXXX/1X22UTP
86 - 108 Fibers O-XXX-LA-HY-FZZNS/ 10 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 174 259 1 Pair XYXXX/1X22UTP
110 - 132 Fibers O-XXX-LA-HY-FZZNS/ 12 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 214 318 1 Pair XYXXX/1X22UTP
134 - 204 Fibers O-XXX-LA-HY-FZZNS/ 18 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 199 296 1 Pair XYXXX/1X22UTP
206 - 276 Fibers O-XXX-LA-HY-FZZNS/ 24 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 258 383 1 Pair XYXXX/1X22UTP
Hybrid Single JacketArmored Cable(108 Fiber Version Shown)
PE Outer Jacket
Binder
22 AWG UTP (1)
Water Swellable Tape
Steel Tape Armoring
Strength Elements
Dielectric Strength Member
Central Member Upjacket
3.0mm Gel Filled Buffer Tubes
250 Micron Fibers
Ripcord (2)
Features & Benefits •Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection • Designed for tone locating when digging and for communications • Used for powering optoelectrical equipment down the line • Provides line fault detection and location
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Hybrid Single Jacket Outdoor CableAll-Dielectric
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 48 Fibers O-XXX-LN-HY-FZZNS/ 5 0.44/11.3 6.7/16.9 4.4/11.3 607/2700 180/800 58 87 1 Pair
XYXXX/1X22UTP
50 - 60 Fibers O-XXX-LN-HY-FZZNS/ 6 0.48/12.3 7.3/18.4 4.8/12.3 607/2700 180/800 71 106 1 Pair XYXXX/1X22UTP
62 - 84 Fibers O-XXX-LN-HY-FZZNS/ 8 0.56/14.3 8.5/21.5 5.6/14.3 607/2700 180/800 96 143 1 Pair XYXXX/1X22UTP
86 - 108 Fibers O-XXX-LN-HY-FZZNS/ 10 0.65/16.4 9.7/24.6 6.5/16.4 607/2700 180/800 123 184 1 Pair XYXXX/1X22UTP
110 - 132 Fibers O-XXX-LN-HY-FZZNS/ 12 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 155 231 1 Pair XYXXX/1X22UTP
134 - 204 Fibers O-XXX-LN-HY-FZZNS/ 18 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 140 209 1 Pair XYXXX/1X22UTP
206 - 276 Fibers O-XXX-LN-HY-FZZNS/ 24 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 191 284 1 Pair XYXXX/1X22UTP
Hybrid Single JacketAll-Dielectric Cable(108 Fiber Version Shown)
PE Outer Jacket
Binder
22 AWG UTP (1)
Water Swellable Tape
Strength Elements
Dielectric Strength Member
Central Member Upjacket
3.0mm Gel Filled Buffer Tubes
250 Micron Fibers
Ripcord
Features & Benefits •Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Designed for communications and tone locating when digging • Used for powering optoelectrical equipment down the line • Provides line fault detection and location
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
F54
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Hybrid Single Jacket Outdoor Cable + ConductorArmored
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load WeightProduct Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 48 Fibers O-XXX-LA-HY-FZZNS/ 5 0.50/12.7 7.5/19.0 5.0/12.7 607/2700 180/800 113 1681-4 Conductors
XYXXX/NX12AWG
50 - 60 Fibers O-XXX-LA-HY-FZZNS/ 6 0.54/13.7 8.1/20.5 5.4/13.7 607/2700 180/800 128 1911-4 Conductors XYXXX/NX12AWG
62 - 84 Fibers O-XXX-LA-HY-FZZNS/ 8 0.62/15.7 9.3/23.6 6.2/15.7 607/2700 180/800 160 2381-4 Conductors XYXXX/NX12AWG
86 - 108 Fibers O-XXX-LA-HY-FZZNS/ 10 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 193 2871-4 Conductors XYXXX/NX12AWG
110 - 132 Fibers O-XXX-LA-HY-FZZNS/ 12 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 232 3461-4 Conductors XYXXX/NX12AWG
134 - 204 Fibers O-XXX-LA-HY-FZZNS/ 18 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 217 3231-4 Conductors XYXXX/NX12AWG
206 - 276 Fibers O-XXX-LA-HY-FZZNS/ 24 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 276 4111-4 Conductors XYXXX/NX12AWG
Hybrid Single JacketAll-Dielectric Cable(108 Fiber Version Shown)
PE Outer Jacket
Steel Tape Armoring
Water Swellable Tape
Strength Elements
3.0mm Gel Filled Buffer Tubes
Dielectric Strength Member
12 AWG Copper Conductor White (1)
Binder
250 Micron Fibers
Ripcord (1)
Features & Benefits • Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection • Designed for tone locating when digging • Provides line fault detection and location
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Copper Conductors Color Coding: Specified by customer
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Copper Conductors are identified with a standard color coding: 1/Red, 2/Black, 3/Green, 4/Brown
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Hybrid Single Jacket Outdoor Cable + ConductorAll-Dielectric
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load WeightProduct Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km
2 - 48 Fibers O-XXX-LN-HY-FZZNS/ 5 0.44/11.3 6.7/16.9 4.4/11.3 607/2700 180/800 76 1141-4 Conductors
XYXXX/NX12AWG
50 - 60 Fibers O-XXX-LN-HY-FZZNS/ 6 0.48/12.3 7.3/18.4 4.8/12.3 607/2700 180/800 89 1331-4 Conductors XYXXX/NX12AWG
62 - 84 Fibers O-XXX-LN-HY-FZZNS/ 8 0.56/14.3 8.5/21.5 5.6/14.3 607/2700 180/800 114 1701-4 Conductors XYXXX/NX12AWG
86 - 108 Fibers O-XXX-LN-HY-FZZNS/ 10 0.65/16.4 9.7/24.6 6.5/16.4 607/2700 180/800 142 2111-4 Conductors XYXXX/NX12AWG
110 - 132 Fibers O-XXX-LN-HY-FZZNS/ 12 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 174 2591-4 Conductors XYXXX/NX12AWG
134 - 204 Fibers O-XXX-LN-HY-FZZNS/ 18 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 159 2361-4 Conductors XYXXX/NX12AWG
206 - 276 Fibers O-XXX-LN-HY-FZZNS/ 24 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 210 3121-4 Conductors XYXXX/NX12AWG
Hybrid Single JacketAll-Dielectric Cable(108 Fiber Version Shown)
PE Outer Jacket
Water Swellable Tape
Strength Elements
3.0mm Gel Filled Buffer Tubes
Dielectric Strength Member
12 AWG Copper Conductor White (1)
Binder
250 Micron Fibers
Ripcord (1)
Features & Benefits • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Designed for tone locating when digging • Provides line fault detection and location
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
F56
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Single Jacket Single Armor Outdoor Cable + ConductorArmored and Non-Armored, All Dielectric
Features & Benefits • Arid-Core® water blocking technology helps protect fibers from moisture and reduces termination effort • Designed for tone locating when digging • Provides line fault detection and location
Specifications are subject to change without notice.
*Weights were calculated using a single 12 AWG conductor. Providing number of conductors, custom tables are available upon request.
Product Type/ Catalog Subunits
Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km
Armored 278-408 Fibers O-XXX-LA-HY-F24NS/ 18 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 261 389 1-4 Conductors XYXXX/NX12AWG
410-552 Fibers O-XXX-LA-HY-F24NS/ 24 1.03/26.2 15.4/39.2 10.3/26.2 607/2700 180/800 337 502 1-4 Conductors XYXXX/NX12AWG
All-Dielectric 278-408 Fibers O-XXX-LN-HY-F24NS/ 18 0.84/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 194 289 1-4 Conductors XYXXX/NX12AWG
410-552 Fibers O-XXX-LN-HY-F24NS/ 24 0.97/24.8 14.6/39.2 9.8/24.8 607/2700 180/800 261 388 1-4 Conductors XYXXX/NX12AWG
Single Jacket Single Armor OutdoorCable + Conductor(552 Fiber Armored,1 x 12 AWG Version Shown)
12 AWG Copper Conductor (1)
PE Outer Jacket
Steel Tape Armor
Strength Elements
Binder
Water Swellable Tape
3.5mm Gel Filled Buffer Tubes
250 Micron Fibers
Dielectric Strength Member
Ripcord (1)
Environmental Specifications Installation Temperature -22° to +158°F (-30° to +70°C)
Operating Temperature -40° to +158°F (-40° to +70°C)
Storage Temperature -40° to +167°F (-40° to +75°C)
Mechanical Test Specifications Test Requirement Test Method
Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7
Flex 35 Cycles FOTP-24; IEC 60794-1-2; Sec. 10
Impact Cable Diameter Dependant FOTP-25; IEC 60794-1-2; Sec. 8
Strain See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5
Twist 10 Cycles FOTP-85; IEC 60794-1-2; Sec. 11
Water Penetration 24 Hours FOTP-82; IEC 60794-1-2; Sec. 24
Environmental Test Specifications Test Requirement Test Method
Cable Freeze 28° F (-2° C) FOTP-98
Drip 140°F (+70° C) FOTP-81; IEC 60794-1-2; Sec. 17
Heat Age -40° to +185°F (-40° to +85°C) N/A
Low High Bend -22° to +140°F (-30° to +60°C) FOTP-28; IEC 60794-1-2; Sec. 28
Temperature Cycle -40° to +158°F (-40° to +70°C) 24 HoursCommScope Optical Cables are qualified under the general guidelines to the following specifications:ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Buffer Tubes 13-23 repeat color sequence with tracer stripe
Copper Conductors Color Coding: Specified by customer
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua
Jacket Color: UV Stabilized Black
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
LSZH Indoor/OutdoorRiser-Rated Distribution Cable (Multi-Unit)(72 Fiber Version Shown)
Low-Smoke Zero-Halogen(LSZH) Outer Jacket
Triathlon® Subunit with Arid-Core®
Central Strength Member
Water Blocking Tapes
Ripcord
LSZH Construction Permits Riser Applications as Well • Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards • Riser rating eliminates splice points at the building entrance • Arid-Core® water blocking technology helps protect fibers from moisture • Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment • Tight buffered construction reduces installation cost
Indoor/Outdoor LSZH Distribution CableLow-Smoke Zero-Halogen, Riser-Rated
12 Fiber Unit (Single Unit)LSZH JacketAramid YarnCentral Strength Member900 Micron Tight-Buffered 250 Micron FiberRipcordWater Blocking Thread
Specifications are subject to change without notice.
Fiber Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Count Number Diameter Loaded Unloaded Short term Long term lbs/kft kg/km
2 Fibers (no central member) Z-ØØ2-DS-XY-FSUBK 0.15/3.8 3.0/7.7 1.5/3.8 225/1001 68/300 7.8 11.6
4 Fibers (no central member) Z-ØØ4-DS-XY-FSUBK 0.20/5.1 4.0/10.1 2.0/5.1 300/1335 90/400 13.5 20.1
6 Fibers Z-ØØ6-DS-XY-FSUBK 0.22/5.5 4.4/11.1 2.2/5.5 300/1335 90/400 17.6 26.3
8 Fibers Z-ØØ8-DS-XY-FSUBK 0.25/6.3 5.0/12.6 2.5/6.3 300/1335 90/400 23.7 35.3
12 Fibers Z-Ø12-DS-XY-FSUBK 0.28/7.2 5.6/14.2 2.8/7.1 400/1780 120/534 32.6 48.6
18 Fibers Z-Ø18-DS-XY-FSUBK 0.31/7.9 6.2/15.7 3.1/7.9 300/1335 90/400 37.0 55.0
24 Fibers Z-Ø24-DS-XY-FSUBK 0.34/8.7 6.8/17.4 3.4/8.7 300/1335 90/400 45.2 67.3
36 Fibers Z-Ø36-DS-XY-FMUBK 0.70/17.8 14.0/35.6 7.0/17.8 800/3560 240/1068 162.4 241.6
48 Fibers Z-Ø48-DS-XY-FMUBK 0.80/20.2 16.0/40.6 8.0/20.3 800/3560 240/1068 206.6 307.4
60 Fibers Z-Ø60-DS-XY-FMUBK 0.87/22.0 17.4/44.2 8.7/22.1 1000/4450 300/1335 260.7 387.9
72 Fibers Z-Ø72-DS-XY-FMUBK 0.95/24.1 19.0/48.2 9.5/24.1 1000/4450 300/1335 320.5 477.0
Singlemode/Multimode Z-ØØØ-DS-CM-FSUBK/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4 - 72 Fibers) Z-ØØØ-DS-CM-FMUBK/AAaaa/BBbbb
Mechanical Properties Description Specification Test Method
Operating Temperature -40° to 158°F (-40° to 70°C) FOTP-3 Installation Temperature -22° to 158°F (-30° to 70°C) N/A Storage Temperature -40° to 167°F (-40° to 75°C) N/A Crush Resistance Exceeds 126 lbf/in (22 N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb·ft (5.88 N·m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85
CommScope Fiber Optic Premises cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2.
F58
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Indoor/Outdoor LSZH Simplex Cable
LSZH Riser RatedOuter Jacket
Water Blocking SystemAramid Yarn900µm Tight Buffer250µm Optical Fiber
Indoor/Outdoor LSZH2-Fiber Interconnect Cable
LSZH Riser Rated Outer Jacket
Aramid YarnWater Blocking System900µm Tight Buffer
250µm Optical Fibers
LSZH Construction Permits Riser Applications as Well • Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards • Riser rating eliminates splice points at the building entrance • Arid-Core® water blocking technology helps protect fibers from moisture • Low-Smoke Zero-Halogen gives added protection to building occupants and equipment • Simplex and zipcord cables are available in a variety of sizes • Designed for ease of handling and termination
Indoor/Outdoor LSZH Cordage CableLow-Smoke Zero-Halogen, Riser-Rated
Specifications are subject to change without notice.
Indoor/Outdoor LSZH Zipcord Cable
LSZH Riser RatedOuter Jacket
Aramid YarnWater Blocking System
900µm Tight Buffer
250µm Optical Fiber
Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./Newtons kft km
Simplex/1.6mm Z-ØØ1-SP-XY-F16BK 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 1.9 2.9
Simplex/2.5mm Z-ØØ1-SP-XY-F25BK 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.5 6.7
Simplex/2.9mm Z-ØØ1-SP-XY-F29BK 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 6.2 9.2
Zipcord/1.6mm Z-ØØ2-ZC-XY-F16BK 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 3.8 5.6 1.70 x 3.50
Zipcord/2.5mm Z-ØØ2-ZC-XY-F25BK 0.098 x 0.201/ 2.0/5.0 1.2/3.0 90/400 27/120 9.0 13.4 2.50 x 5.10
Zipcord/2.9mm Z-ØØ2-ZC-XY-F29BK 0.114 x 0.232/ 2.3/5.8 1.2/3.0 90/400 27/120 12.4 18.5 2.90 x 5.90
Interconnect/2.9mm Z-ØØ2-IC-XY-F29BK 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 5.0 7.4
Mechanical Properties Description Specification Test Method
Operating Temperature -40° to 158°F (-40° to 70°C) FOTP-3
Installation Temperature -22° to 158°F (-30° to 70°C) N/A
Storage Temperature -40° to 167°F (-40° to 75°C) N/A
Crush Resistance Exceeds 57 lbf/in (10 N/mm) FOTP-41
Impact Resistance Exceeds 0.54 lbf·ft (0.74 N·m) FOTP-25
Flexing Exceeds 300 cycles FOTP-104
Twist Bend Exceeds FOTP-85
CommScope Fiber Optic Premise cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber
For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer/Fiber Identification Colors: 1/Blue, 2/Orange
Jacket Color: UV Stabilized Black
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Premise Riser-Rated Distribution Cable
For Indoor Applications that Require a Riser Rating • Meets critical NEC/CEC riser (OFNR) safety standards • Colored-Coded and color-coded fibers help ease installation
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./Newtons kft km
2 Fibers R-ØØ2-DS-XY-FSUZZ 0.16/4.1 3.2/8.1 1.6/4.1 225/1001 68/300 8.6 12.9
4 Fibers R-ØØ4-DS-XY-FSUZZ 0.19/4.8 3.8/9.5 1.9/4.8 300/1335 90/400 13.1 19.4
6 Fibers R-ØØ6-DS-XY-FSUZZ 0.20/5.1 4.1/10.3 2.0/5.1 300/1335 90/400 15.2 22.7
8 Fibers R-ØØ8-DS-XY-FSUZZ 0.22/5.5 4.3/11.0 2.2/5.5 300/1335 90/400 17.2 25.7
12 Fibers R-Ø12-DS-XY-FSUZZ 0.24/6.0 4.7/12.1 2.4/6.0 300/1335 90/400 21.7 32.2
18 Fibers R-Ø18-DS-XY-FSUZZ 0.30/7.7 6.0/15.4 3.0/7.7 300/1335 90/400 32.1 47.7
24 Fibers R-Ø24-DS-XY-FSUZZ 0.33/8.4 6.6/16.7 3.3/8.4 300/1335 90/400 37.9 56.4
36 Fibers (3 subunits) R-Ø36-DS-XY-FMUZZ 0.58/14.6 11.5/29.3 5.8/14.6 800/3560 240/1068 112.0 167.0
48 Fibers (4 subunits) R-Ø48-DS-XY-FMUZZ 0.63/16.1 12.7/32.2 6.3/16.1 800/3560 240/1068 143.0 212.0
60 Fibers (5 subunits) R-Ø6Ø-DS-XY-FMUZZ 0.71/18.0 14.2/36.1 7.1/18.0 1000/4450 300/1335 188.0 279.0
72 Fibers (6 subunits) R-Ø72-DS-XY-FMUZZ 0.79/20.0 15.8/40.1 7.9/20.0 1000/4450 300/1335 232.0 345.0
96 Fibers (8 subunits) R-Ø96-DS-XY-FMUZZ 0.93/23.7 18.7/47.5 9.3/23.7 1000/4450 300/1335 337.0 502.0
144 Fibers (12 subunits) R-144-DS-XY-FMUZZ 1.03/26.1 20.5/52.2 10.3/26.1 1000/4450 300/1335 350.0 522.0
Singlemode/Multimode R-XXX-DS-CM-FSUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4 - 144 Fibers) R-XXX-DS-CM-FMUOR/AAaaa/BBbbb
12 Fiber Unit (Single Unit)Riser Rated Outer JacketAramid Yarn900 µm Tight Buffer
250 µm Optical FiberRipcord
Riser Distribution Cable (Multi-Unit)(72 and 12 Fiber Versions Shown)
Riser Rated Outer Jacket
Core Wrap Tape
Central Strength Member
12 Fiber Subunit
Ripcord
Mechanical Properties
Description Specification Test Method
Operating Temperature -4° to 158°F (-20° to 70°C) FOTP-3 Installation Temperature -4° to 158°F (-20° to 70°C) N/A Storage Temperature -40° to 158°F (-40° to 70°C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb·ft (5.88 N·m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85
CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber
For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded in the same manner.
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F60
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Riser Zipcord Cable
Riser Rated Outer Jacket
Aramid Yarn
900 µm Tight Buffer
250 µm Optical Fiber
Riser 2-Fiber Interconnect CableRiser Rated Outer JacketAramid Yarn900 µm Tight Buffer250 µm Optical Fiber
Riser Simplex CableRiser Rated Outer Jacket900 µm Tight Buffer250 µm Optical FiberAramid Yarn
Premise Riser-Rated Cordage CableSeveral Constructions Available for a Variety of Applications
For Indoor Applications that Require a Riser Rating • Meets critical NEC/CEC riser (OFNR) safety standards • Simplex and zipcord cables are available in a variety of sizes • Designed for ease of handling and termination
Specifications are subject to change without notice.
Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./Newtons kft km
Simplex/1.6mm R-ØØ1-SP-XY-F16ZZ 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 1.8 2.7
Simplex/2.0mm R-ØØ1-SP-XY-F20ZZ 0.079/2.00 2.0/5.0 1.2/3.0 50/222 15/67 2.8 4.1
Simplex/2.5mm R-ØØ1-SP-XY-F25ZZ 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.2 6.3
Simplex/2.9mm R-ØØ1-SP-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 5.8 8.7
Zipcord/1.6mm R-ØØ2-ZC-XY-F16ZZ 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 3.7 5.5 1.70 x 3.50
Zipcord/2.0mm R-ØØ2-ZC-XY-F20ZZ 0.079 x 0.161/ 2.0/5.0 1.2/3.0 80/356 24/107 5.4 8.0 2.00 x 4.10
Zipcord/2.5mm R-ØØ2-ZC-XY-F25ZZ 0.098 x 0.201/ 2.0/5.0 1.2/3.0 90/400 27/120 8.5 12.6 2.50 x 5.10
Zipcord/2.9mm R-ØØ2-ZC-XY-F29ZZ 0.114 x 0.232/ 2.3/5.8 1.2/3.0 90/400 27/120 11.7 17.4 2.90 x 5.90
Interconnect /2.9mm R-ØØ2-IC-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 4.7 7.0
Mechanical Properties Description Specification Test Method
Operating Temperature -4° to 158°F (-20° to 70°C) FOTP-3 Installation Temperature -4° to 158°F (-20° to 70°C) N/A Storage Temperature -40° to 158°F (-40° to 70°C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb·ft (0.74 N·m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85
CommScope Fiber Optic Premises Cables are qualified to the requirements of TelcordiaGR-409-CORE, Issue 1.
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber
ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Premise Plenum-Rated Distribution Cable
For Indoor Applications that Require a Plenum Rating • Meets critical NEC/CEC plenum (OFNP) safety standards • Color-coded subunits and color-coded fibers help ease installation
Specifications are subject to change without notice.
Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./Newtons kft km
2 Fibers P-ØØ2-DS-XY-FSUZZ 0.15/3.9 3.1/7.8 1.5/3.9 225/1001 68/300 8.8 13.1
4 Fibers P-ØØ4-DS-XY-FSUZZ 0.17/4.4 3.4/8.7 1.7/4.4 300/1335 90/400 12.2 18.2 6 Fibers P-ØØ6-DS-XY-FSUZZ 0.19/4.8 3.8/9.7 1.9/4.8 300/1335 90/400 15.1 22.5
8 Fibers P-ØØ8-DS-XY-FSUZZ 0.20/5.1 4.0/10.2 2.0/5.1 300/1335 90/400 16.8 24.9
12 Fibers P-Ø12-DS-XY-FSUZZ 0.23/5.8 4.6/11.7 2.3/5.8 300/1335 90/400 20.8 30.9
18 Fibers P-Ø18-DS-XY-FSUZZ 0.31/7.9 6.2/15.8 3.1/7.9 300/1335 90/400 40.9 60.9
24 Fibers P-Ø24-DS-XY-FSUZZ 0.33/8.5 6.7/16.9 3.3/8.5 300/1335 90/400 47.3 70.4
36 Fibers (3 subunits) P-Ø36-DS-XY-FMUZZ 0.54/13.7 10.8/27.4 5.4/13.7 800/3560 240/1068 128.0 191.0
48 Fibers (4 subunits) P-Ø48-DS-XY-FMUZZ 0.59/15.1 11.9/30.2 5.9/15.1 800/3560 240/1068 138.0 205.0
60 Fibers (5 subunits) P-Ø6Ø-DS-XY-FMUZZ 0.68/17.2 13.6/34.4 6.8/17.2 1000/4450 300/1335 190.0 282.0
72 Fibers (6 subunits) P-Ø72-DS-XY-FMUZZ 0.75/19.1 15.1/38.2 7.5/19.1 1000/4450 300/1335 237.0 353.0
96 Fibers (8 subunits) P-Ø96-DS-XY-FMUZZ 0.91/23.1 18.2/46.1 9.1/23.1 1000/4450 300/1335 361.0 537.0 144 Fibers (12 subunits) P-144-DS-XY-FMUZZ 0.97/24.8 19.5/49.5 9.7/24.8 1000/4450 300/1335 357.0 531.0
Singlemode/Multimode P-XXX-DS-CM-FSUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4 - 144 Fibers) P-XXX-DS-CM-FMUOR/AAaaa/BBbbb
Plenum Distribution Cable (Multi-Unit)(72 and 12 Fiber Versions Shown)
Plenum Rated Outer Jacket
Central Strength Member
12 Fiber Subunit
Ripcord
Mechanical Properties
Description Specification Test Method
Operating Temperature -4° to 158°F (-20° to 70°C) FOTP-3 Installation Temperature 32° to 158°F (0° to 70°C) N/A Storage Temperature -40° to 158°F (-40° to 70°C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb·ft (5.88 N·m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85CommScope Fiber Optic Premises Cables are qualified to the requirements of TelcordiaGR-409-CORE, Issue 1.
12 Fiber Unit (Single Unit)Riser Rated Outer JacketAramid Yarn900 µm Tight Buffer
250 µm Optical FiberRipcord
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber
For Composites Only: aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded for easy identification
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
F62
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Premise Plenum-Rated Cordage CableSeveral Constructions Available for a Variety of Uses
For Indoor Applications that Require a Plenum Rating• Meets critical NEC/CEC plenum (OFNP) safety standards • Simplex and zipcord cables are available in a variety of sizes• Designed for ease of handling and termination
Specifications are subject to change without notice.
Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./Newtons kft km
Simplex/1.6mm P-ØØ1-SP-XY-F16ZZ 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 2.0 3.0
Simplex/2.0mm P-ØØ1-SP-XY-F20ZZ 0.079/2.00 2.0/5.0 1.2/3.0 50/222 15/67 3.0 4.5
Simplex/2.5mm P-ØØ1-SP-XY-F25ZZ 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.9 7.3
Simplex/2.9mm P-ØØ1-SP-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 6.8 10.1
Zipcord/1.6mm P-ØØ2-ZC-XY-F16ZZ 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 4.0 6.0 1.70 x 3.50
Zipcord/2.0mm P-ØØ2-ZC-XY-F20ZZ 0.079 x 0.161/ 2.0/5.0 1.2/3.0 80/356 24/107 5.9 8.8 2.00 x 4.10
Zipcord/2.5mm P-ØØ2-ZC-XY-F25ZZ 0.098 x 0.201/ 2.0/5.0 1.2/3.0 90/400 27/120 9.8 14.6 2.50 x 5.10
Zipcord/2.9mm P-ØØ2-ZC-XY-F29ZZ 0.114 x 0.232/ 2.3/5.8 1.2/3.0 90/400 27/120 13.6 20.2 2.90 x 5.90
Interconnect/2.9mm P-ØØ2-IC-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 5.8 8.6
Mechanical Properties
Description Specification Test Method
Operating Temperature -4° to 158°F (-20° to 70°C) FOTP-3 Installation Temperature 32° to 158°F (0° to 70°C) N/A Storage Temperature -40° to 158°F (-40° to 70°C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb·ft (0.74 N·m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85CommScope Fiber Optic Premises Cables are qualified to the requirements of TelcordiaGR-409-CORE, Issue 1.
Plenum Zipcord Cable
Plenum Rated Outer Jacket
Aramid Yarn
900 µm Tight Buffer
250 µm Optical Fiber
Plenum 2-Fiber Interconnect CablePlenum Rated Outer JacketAramid Yarn900 µm Tight Buffer250 µm Optical Fiber
Plenum Simplex CablePlenum Rated Outer Jacket900 µm Tight Buffer250 µm Optical FiberAramid Yarn
Variables in the Catalog Number: XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP® Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZDTM Non-Zero Dispersion- Shifted Singlemode Fiber
ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange
6F 62.5µm, FDDI Grade Multimode Fiber5M LazrSPEED® 150, 50µm, Multimode Fiber
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fiber Optic CablePackaging and Shipping Information
Packaging and ShippingFiber optic cable is packaged for shipment on wooden or composite reels. Each package contains only one continuous length of cable. The packaging is designed to prevent damage to the cable during shipping and handling. Fiber cable reels are protected with a “reel wrap”, the highest technology available today. This wrap is stronger, lighter and more environmentally friendly than other methods of lagging. In addition, reel wrap is simple to remove from the reel and readily disposable. All reel sizes between 35 and 78 inches will be blocked and palletized to help ensure safe arrival to the customer. Reels larger than 78 inches are placed on the rolling edge and securely fastened to the trailer during shipment.
Each reel is plainly marked to indicate the direction in which it should be rolled to prevent loosening of the cable on the reel.
Method of Shipment CommScope’s customary method of shipment of fiber optic cable from Claremont, North Carolina to the purchaser’s site will vary depending on factors such as the size and number of cable reels, and the destination location. Shipper options include Federal Express, UPS, BAX, LTL motor freight carriers and CommScope’s own fleet of trucks, “Cable Transport”. Some trucks within CommScope’s fleet are equipped with “Cargo Master” equipment for ease in unloading cable reels on location where no loading dock is available. CommScope has red arm Cargo Masters, which can lift anything 2,500 pounds or less. CommScope also has white arm Cargo Masters which will lift anything up to 8,000 pounds that is on an 84” reel or smaller. These specially equipped trucks are available by request.
International PackagingProducts shipped outside the continental United States are protected with reel wrap, lagged with wood, and blocked and palletized (for reel sizes between 35 and 78 inches) or placed on the rolling edge and securely fastened to international shipping containers.
DDrum
Diameter
FFlange
Diameter
TTraverse Width
F64
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Reel Weights subject to change without notice.
Fiber Optic CablePackaging and Shipping Information
Outside Plant Dry Stranded Loose Tube Armored (D-LA) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
35 x 16.5 x 18 70 3,805 3,752 2,834 2,414 1,742 1,722 1,411
42 x 24 x 24 109 6,706 6,008 4,988 3,838 3,101 3,101 2,510
42 x 22 x 29.75 118 8,816 8,021 6,249 5,231 3,885 3,885 3,165
48 x 22 x 32.5 140 15,058 13,828 10,597 8,624 6,868 6,868 5,279
54 x 24 x 28 350 16,987 15,888 12,526 9,881 7,914 7,914 5,821
60 x 30 x 32 433 22,681 20,988 16,528 12,973 10,548 10,548 7,724
66 x 30 x 31 580 29,384 26,363 20,713 16,715 12,885 12,885 9,987
72 x 36 x 36 627 38,603 34,883 27,084 21,831 17,174 17,174 13,002
78 x 36 x 36 758 47,398 44,759 34,523 27,371 22,174 22,114 16,407
84 x 40 x 40 850 59,951 56,558 43,978 35,569 27,634 27,634 20,574
88 x 40 x 40 958 N/A 59,942 50,344 39,867 31,433 31,433 23,844
96 x 44 x 46 1,125 N/A N/A 59,910 56,045 42,748 42,748 33,491
All Units in Feet 2”Flange Clearance
Outside Plant Dry Stranded Loose Tube Non-Armored (D-LN) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
35 x 16.5 x 18 70 5,195 4,783 3,671 2,847 2,054 2,054 1,704
42 x 24 x 24 109 8,572 7,784 6,029 4,566 3,683 3,683 2,630
42 x 22 x 29.75 118 11,173 10,816 7,922 6,156 4,614 4,614 3,755
48 x 22 x 32.5 140 19,027 17,654 12,932 10,648 7,832 7,832 6,035
54 x 24 x 28 350 21,977 20,432 15,705 11,680 8,819 8,819 7,157
60 x 30 x 32 433 29,256 27,346 20,773 15,736 11,903 11,903 9,388
66 x 30 x 31 580 36,834 34,662 26,098 20,458 15,199 15,199 11,848
72 x 36 x 36 627 48,165 45,550 34,589 26,798 20,008 20,008 15,583
78 x 36 x 36 758 59,950 56,756 42,952 34,179 25,296 25,296 19,307
84 x 40 x 40 850 N/A 59,942 54,434 42,065 33,135 33,135 23,925
88 x 40 x 40 958 N/A N/A 59,910 48,310 37,275 37,275 27,448
96 x 44 x 46 1125 N/A N/A N/A 59,872 46,351 46,351 33,491 All Units in Feet 2”Flange Clearance
Outside Plant Dry Loose Tube Double Jacket, Single Armor (D-L2) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
35 x 16.5 x 18 70 2,407 2,110 1,735 1,449 1,191 1,191 N/A
42 x 24 x 24 109 3,831 3,756 3,091 2,560 2,083 2,083 1,651
42 x 22 x 29.75 118 5,328 5,145 3,963 3,289 2,684 2,684 2,204
48 x 22 x 32.5 140 8,760 8,509 6,835 5,932 4,651 4,651 3,913
54 x 24 x 28 350 10,464 9,727 7,874 6,517 5,595 5,595 4,319
60 x 30 x 32 433 13,973 12,793 10,502 8,590 7,459 7,459 5,864
66 x 30 x 31 580 17,505 16,490 13,106 10,960 9,034 9,034 7,270
72 x 36 x 36 627 23,217 21,578 17,098 14,480 11,843 11,843 9,442
78 x 36 x 36 758 28,917 27,071 22,003 19,034 15,108 15,108 11,597
84 x 40 x 40 850 35,461 35,237 27,501 23,625 19,069 19,069 15,869
88 x 40 x 40 958 41,206 39,508 31,272 27,115 22,231 22,231 17,770
96 x 44 x 46 1125 55,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2”Flange Clearance
F65
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Outside Plant Stranded Loose Tube Armored (O-LA/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
3 35 x 16.5 x 18 70 4,118 3,746 2,831 2,411 1,741 1,741 1,410
42 x 24 x 24 109 6,832 6,121 5,097 3,836 3,099 3,099 2,509
42 x 22 x 29.75 118 8,950 8,615 6,778 5,227 3,882 3,882 3,163
48 x 22 x 32.5 140 15,045 14,008 10,761 8,615 6,861 6,861 5,276
54 x 24 x 28 350 16,972 15,856 12,506 9,869 7,906 7,906 5,817
60 x 30 x 32 433 22,663 21,265 16,786 12,960 10,539 10,539 7,719
66 x 30 x 31 580 29,357 27,785 21,621 16,697 12,872 12,872 9,980
72 x 36 x 36 627 38,572 36,172 28,238 21,809 17,158 17,158 12,994
78 x 36 x 36 758 48,885 44,670 34,470 28,502 22,092 22,092 16,396
84 x 40 x 40 850 59,951 57,121 44,507 35,530 27,607 27,607 20,560
88 x 40 x 40 958 N/A 59,942 50,944 41,293 31,401 31,401 23,827
96 x 44 x 46 1125 N/A N/a 59,910 55,980 43,342 43,342 33,491 All Units in Feet 2”Flange Clearance
Fiber Optic CablePackaging and Shipping Information
Reel Weights subject to change without notice.
Outside Plant Loose Tube Double Jacket, Single Armor (O-L2/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
35 x 16.5 x 18 70 2,407 2,110 1,735 1,449 1,191 1,191 N/A
42 x 24 x 24 109 3,831 3,756 3,091 2,560 2,083 2,083 1,651
42 x 22 x 29.75 118 5,328 5,145 3,963 3,289 2,684 2,684 2,204
48 x 22 x 32.5 140 8,760 8,509 6,835 5,932 4,651 4,651 3,913
54 x 24 x 28 350 10,464 9,727 7,874 6,517 5,595 5,595 4,319
60 x 30 x 32 433 13,973 12,793 10,502 8,590 7,459 7,459 5,864
66 x 30 x 31 580 17,505 16,490 13,106 10,960 9,034 9,034 7,270
72 x 36 x 36 627 23,217 21,578 17,098 14,480 11,843 11,843 9,442
78 x 36 x 36 758 28,917 27,071 22,003 19,034 15,108 15,108 11,597
84 x 40 x 40 850 35,461 35,237 27,501 23,625 19,069 19,069 15,869
88 x 40 x 40 958 41,206 39,508 31,272 27,115 22,231 22,231 17,770
96 x 44 x 46 1125 55,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2”Flange Clearance
Outside Plant Stranded Loose Tube Non-Armored (O-LN/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1
35 x 16.5 x 18 70 5,189 4,773 3,666 2,8473 2,052 2,052 1,703
42 x 24 x 24 109 8,565 7,772 6,023 4,562 3,681 3,681 2,629
42 x 22 x 29.75 118 11,162 10,797 7,911 6,149 4,611 4,611 3,752
48 x 22 x 32.5 140 19,002 17,847 13,878 10,633 7,825 7,825 6,031
54 x 24 x 28 350 21,947 20,693 15,677 12.329 9,001 9,011 7,152
60 x 30 x 32 433 29,221 27,651 21.056 16,579 11,895 11,895 9,382
66 x 30 x 31 580 36,785 34,583 26,054 20,428 15,186 15,186 11,849
72 x 36 x 36 627 48,108 45,458 34,537 26,762 19,992 19,992 15,573
78 x 36 x 36 758 59,952 56,628 42,879 34,127 25,274 25,274 19,292
84 x 40 x 40 850 N/A 59,942 54,346 44,128 33,108 33,108 23,908
88 x 40 x 40 958 N/A N/A 59,910 48,896 37,242 37,242 27,427
96 x 44 x 46 1125 N/A N/A N/A 59,873 46,351 46,351 33,491 All Units in Feet 2”Flange Clearance
F66
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Outside Plant Stranded Loose Tube Armored (O-LA/20T) and Loose Tube Non-Armored (O-LN/20T) Cables Armored (O-LA/20T) Non-Armored (O-LN/20T) Flange x Drum x Reel 2-72 74-96 98-120 122-144 2-72 74-96 98-120 122-144 Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1
35 x 16.5 x 18 70 4,698 3,666 3,169 2,470 5,935 4,766 3,731 2,901
42 x 24 x 24 109 7,678 6,023 5,178 4,313 9,786 7,901 6,609 5,076
42 x 22 x 29.75 118 10,032 7,911 6,978 5,403 13,244 10,939 8,725 6,871
48 x 22 x 32.5 140 16,664 13,878 11,540 9,487 21,938 17,820 14,151 11,578
54 x 24 x 28 350 19,397 15,677 13,568 10,599 24,908 20,659 16,834 12,668
60 x 30 x 32 433 26,033 21,056 17,818 14,131 33,282 27,612 22,501 16,975
66 x 30 x 31 580 32,770 26,054 21,785 17,697 42,214 34,527 27,656 21,859
72 x 36 x 36 627 43,244 34,537 28,837 23,428 55,904 45,920 36,497 28,503
78 x 36 x 36 758 54,160 42,879 36,490 29,155 59,962 57,194 46,540 36,083
84 x 40 x 40 850 59,962 54,346 46,879 37,670 N/A 59,945 59,333 46,421
88 x 40 x 40 958 N/A 59,945 53,479 43,599 N/A N/A 59,920 52,968
96 x 44 x 46 1125 N/A N/A 59,920 58,733 N/A N/A N/A 59,885 All Units in Feet 2”Flange Clearance
Outside Plant Stranded Loose Tube Armored (Z-LA/20G) and Loose Tube Non-Armored (Z-LN/20G) Cables Armored (Z-LA/20G) Non-Armored (Z-LN/20G)Flange x Drum x Reel 2-72 74-96 98-120 122-144 2-72 74-96 98-120 122-144 Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1
35 x 16.5 x 18 70 3,383 2,838 2,469 2,066 4,276 3,753 2,901 2,471
42 x 24 x 24 109 5,923 4,993 4,312 3,601 7,572 6,010 5,076 4,315
42 x 22 x 29.75 118 7,813 6,256 5,403 4,536 9,784 8,023 6,871 5,406
48 x 22 x 32.5 140 12,784 10,612 9,485 7,727 16,317 13,832 11,578 9,493
54 x 24 x 28 350 14,747 12,545 10,596 8,878 18,383 15,893 12,668 10,606
60 x 30 x 32 433 19,573 16,550 14,128 11,737 24,408 20,994 16,975 14,140
66 x 30 x 31 580 24,770 20,387 17,693 14,988 31,366 26,371 21,859 17,709
72 x 36 x 36 627 32,930 27,120 23,423 19,773 40,990 34,892 28,503 23,443
78 x 36 x 36 758 42,545 34,575 29,148 23,932 51,613 44,772 36,083 29,175
84 x 40 x 40 850 53,982 44,042 37,662 31,000 59,962 56,574 46,421 37,696
88 x 40 x 40 958 59,962 50,423 43,589 34,989 N/A 59,945 52,968 43,631
96 x 44 x 46 1125 N/A 59,945 58,719 48,345 N/A N/A 59,920 58,775 All Units in Feet 2”Flange Clearance
Outside Plant Stranded Loose Tube Armored (O-LA), Loose Tube Non-Armored (O-LN) andLoose Tube Double Jacket, Single Armored (O-L2) High Density Cables Armored (O-LA) Non-Armored (O-LN) Double Jacket, Single Armored (O-L2)
Flange x Drum x Reel 290-432F 434-576F 290-432F 434-576F 290-432F Traverse Weight (lbs) 12@6@1 15@9@1 12@6@1 15@9@1 12@6@1
35 x 16.5 x 18 70 N/A N/A N/A N/A N/A
42 x 24 x 25 109 1,713 1,327 2,099 1,612 1,325
42 x 22 x 29.75 118 2,270 1,713 2,709 2,104 1,770
48 x 22 x 32.5 176 4,019 2,884 4,585 3,387 2,875
54 x 24 x 28 370 4,456 3,341 5,059 3,757 3,330
60 x 30 x 32 433 5,855 4,469 6,781 4,998 4,457
66 x 30 x 32 506 7,472 5,902 9,145 6,483 5,882
72 x 36 x 36 627 9,670 7,327 11,427 8,484 7,521
78 x 36 x 36 758 12,648 9,224 13,778 10,545 9,464
84 x 40 x 40 913 15,844 11,853 17,518 13,389 12,126
88 x 40 x 40 958 17,740 13,489 20,545 15,143 13,796
96 x 44 x 46 1,020 24,298 18,714 27,682 20,696 19,074 All Units in Feet 2”Flange Clearance
Fiber Optic CablePackaging and Shipping Information
Reel Weights subject to change without notice.F67
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Reel Weights subject to change without notice.
Outside Plant Figure-8 Armored (M-LA) and Non-Armored (M-LN) Cables
Outside Plant Figure-8 Armored (M-LA/25D) and Non-Armored (M-LN/25D) Cables
Flange x Drum x Reel 5@1 6@1 12@1 12@6 15@9 5@1 6@1 12@1 12@6 15@9 Traverse Weight (lbs) 2-60 62-72 74-144 146-216 218-288 2-60 62-72 74-144 146-216 218-288
Flange x Drum x Reel 5@1 1@1 5@1 5@1 5@1 5@1 Traverse Weight (lbs) 2-60 2-60 2-60 2-60 2-60 2-60
Armored (M LA)
Armored (M LA/25D)
Non-Armored (M LN)
Non-Armored (M LN/25D)
35 x 16.5 x 18 70 1,671 1,559 867 867 N/A 1,955 1,748 909 909 N/A
42 x 24 x 24 109 2,807 2,498 1,359 1,359 1,082 3,358 3,036 1,605 1,605 1,309
42 x 22 x 29.75 118 3,726 3,380 1,983 1,983 1,449 4,486 3,994 2,032 2,032 1,711
48 x 22 x 32.5 140 6,218 5,801 2,961 2,961 2,578 7,546 6,733 3,431 3,431 2,637
54 x 24 x 28 350 7,256 6,443 3,594 3,594 2,887 8,653 7,557 3,965 3,965 3,242
60 x 30 x 32 433 9,604 8,569 4,751 4,751 3,862 11,364 10,302 5,417 5,417 4,308
66 x 30 x 32 580 12,283 11,179 6,306 6,306 4,717 14,727 13,068 6,820 6,820 5,198
72 x 36 x 36 627 16,062 14,678 8,271 8,271 6,309 19,587 17,017 8,905 8,905 6,907
78 x 36 x 36 758 20,201 18,030 9,887 9,887 7,752 24,056 21,264 11,129 11,129 8,919
84 x 40 x 40 850 26,345 23,153 13,036 13,036 9,878 30,211 26,957 14,509 14,509 11,256
88 x 40 x 40 958 29,968 26,599 14,411 14,411 11,745 34,498 30,567 15,929 15,929 12,544
96 x 44 x 46 1,125 34,498 34,498 20,364 20,364 16,271 N/A 34,498 22,219 22,219 17,227All Units in Feet 2” Flange Clearance
35 x 16.5 x 18 70 2,266 2,069 1,970 2,773 2,551 2,329
42 x 24 x 24 109 3,719 3,359 3,239 4,633 4,088 3,816
42 x 22 x 29.75 118 5,363 4,799 4,516 6,411 5,785 5,316
48 x 22 x 32.5 140 8,645 7,821 7,410 10,421 9,494 8,800
54 x 24 x 28 350 9,935 8,861 8,324 12,342 11,108 10,182
60 x 30 x 32 433 13,124 11,874 11,249 16,146 14,711 13,634
66 x 30 x 32 580 17,245 15,563 14,722 20,543 18,208 17,275
72 x 36 x 36 627 22,352 20,450 19,023 26,934 24,294 22,709
78 x 36 x 36 758 27,601 25,252 23,490 33,549 30,000 28,286
84 x 40 x 40 850 34,498 30,000 30,215 34,498 N/A 34,498
88 x 40 x 40 958 N/A N/A 34,063 N/A N/A N/A
96 x 44 x 46 1,125 N/A N/A 34,498 N/A N/A N/AAll Units in Feet 2” Flange Clearance
Fiber Optic CablePackaging and Shipping Information
Outside Plant ADSS Loose Tube(S-LN) Cables Flange x Drum x Reel 2-60F Traverse Weight (lbs) 5@1
35 x 16.5 x 18 70 3,733
42 x 24 x 24 109 6,612
42 x 22 x 29.75 118 8,729
48 x 22 x 32.5 140 13,954
54 x 24 x 28 350 16,844
60 x 30 x 32 433 22,187
66 x 30 x 31 580 27,672
72 x 36 x 36 627 36,516
78 x 36 x 36 758 45,075
84 x 40 x 40 850 59,367
88 x 40 x 40 958 66,768
96 x 44 x 46 1,125 85,636All Units in Feet 2”Flange Clearance
F68
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Indoor/Outdoor Stranded Loose Tube Non-Armored (R-LN/25D) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6 15@9
3 35 x 16.5 x 18 70 3,808 3,748 2,831 2,411 1,741 1,691 1,361
42 x 24 x 24 109 6,710 6,123 5,097 3,836 3,099 3,035 2,145
42 x 22 x 29.75 118 8,822 8,619 6,778 5,227 3,882 3,825 3,103
48 x 22 x 32.5 140 15,071 14,016 10,761 8,615 6,860 6,125 4,737
54 x 24 x 28 350 17,002 15,865 12,506 9,869 7,904 7,280 5,715
60 x 30 x 32 433 22,699 21,275 16,786 12,960 10,537 9,533 7,600
66 x 30 x 31 580 29,410 27,380 21,621 16,697 12,870 12,025 9,834
72 x 36 x 36 627 38,634 36,191 28,238 21,809 17,155 15,780 12,830
78 x 36 x 36 758 47,440 44,695 34,470 28,502 22,088 20,519 15,336
84 x 40 x 40 850 59,950 57,152 44,507 35,530 27,602 25,786 20,362
88 x 40 x 40 958 N/A 59,942 50,944 41,293 31,394 29,456 22,510
96 x 44 x 46 1125 N/A N/A 59,910 55,980 43,333 40,371 31,361 All Units in Feet 2”Flange Clearance
Reel Weights subject to change without notice.
Fiber Optic CablePackaging and Shipping Information
Indoor/Outdoor Stranded Loose Tube Plenum Non-Armored (P-LN/25D) Cables andPlenum/Interlocking Armor (P-LZ/25D) Cables
Flange x Drum x Reel 5@1 6@1 8@1 10@1 12@1 5@1 6@1 8@1 10@1 12@1 Traverse Weight (lbs) 2-60 62-72 74-144 146-216 218-288 2-60 62-72 74-144 146-216 218-288
Non-Armored (P-LN/25D) Interlocking Armor (P-LZ/25D)
35 x 16.5 x 18 70 5,466 5,297 3,821 2,901 2,343 N/A N/A N/A N/A N/A
42 x 24 x 24 109 9,523 8,699 6,728 5,076 3,753 2,701 2,701 2,080 2,034 N/A
42 x 22 x 29.75 118 12,224 11,860 8,850 6,871 5,249 3,832 3,832 N/A N/A N/A
48 x 22 x 32.5 140 20,610 19,205 14,120 11,578 8,662 6,140 6,140 N/A N/A N/A
54 x 24 x 28 350 23,795 22,219 16,794 12,668 9,714 7,118 7,118 5,581 4,936 N/A
60 x 30 x 32 433 31,486 29,539 22,455 16,975 13,023 9,555 9,555 7,442 6,637 5,130
66 x 30 x 32 580 40,683 37,957 28,009 21,859 16,468 10,000 10,000 9,012 8,128 6,448
72 x 36 x 36 627 53,412 50,160 36,895 28,503 21,553 N/A N/A 10,000 10,000 8,444
78 x 36 x 36 758 59,950 59,942 47,033 36,083 27,035 N/A N/A N/A N/A 10,000
84 x 40 x 40 850 N/A N/A 59,199 46,421 35,191 N/A N/A N/A N/A N/A
88 x 40 x 40 958 N/A N/A 59,910 52,968 39,453 N/A N/A N/A N/A N/A
96 x 44 x 46 1,125 N/A N/a N/A 59,872 46,351 N/A N/A N/A N/A N/AAll Units in Feet 2” Flange Clearance
Indoor/Outdoor and Outside Plant Central Tube Non-Armored (R-CN, O-CN) Cables Flange x Drum x Reel RCN CN CN CN Traverse Weight (lbs) 1-24 1-24 26-48 50-96
35 x 16.5 x 18 70 5,288 5,288 3,668 2,780
42 x 24 x 24 109 8,687 8,687 6,026 4,485
42 x 22 x 29.75 118 12,006 12,006 7,917 6,076
48 x 22 x 32.5 140 19,168 19,168 12,922 9,707
54 x 24 x 28 350 22,173 22,173 15,691 11,542
60 x 30 x 32 433 29,487 29,487 20,757 15,307
66 x 30 x 31 580 38,371 38,371 26,076 19,003
72 x 36 x 36 627 48,648 48,648 34,563 25,028
78 x 36 x 36 758 N/A N/A 42,915 32,156
84 x 40 x 40 850 N/A N/A 48,593 33,252All Units in Feet 2” Flange Clearance
F69
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected] F70
Fiber Optic CablePackaging and Shipping Information
Outside Plant Flat Drop (O-DF, O-DF/HY) Cables Flange x Drum x Reel ODF ODF/HY Traverse Weight (lbs) 1-12 1-12
34 x 6.75 x 12 1 1,000 11,918
35 x 16.5 x 18 70 14,350 19,606
42 x 24 x 24 92 23,926 25,282
42 x 22 x 29.75 118 31,728 43,324
48 x 22 x 32.5 140 48,685 48,685All Units in Feet 2” Flange Clearance
LZSH Indoor/Outdoor (Z-DN) Cables Flange x Drum x Reel ZDN ZDN/20T Traverse Weight (lbs) 1-12 1-12
35 x 16.5 x 18 70 7,706 14,403
42 x 24 x 24 92 12,980 24,286
42 x 22 x 29.75 118 17,195 32,181
48 x 22 x 32.5 140 28,321 48,685
54 x 24 x 28 350 32,726 N/A
60 x 30 x 32 433 43,439 N/A
66 x 30 x 31 580 48,671 N/AAll Units in Feet 2” Flange Clearance
Outside Plant Drop (O-DA, O-DN, M-MN and M-DN) Cables Flange x Drum x Reel DA DN MMN MDN/109 MDN Traverse Weight (lbs) 1-12 1-12 1-12 1-6 1-12
14 x 6.75 x 12 12 N/A N/A N/A N/A N/A
35 x 16.5 x 18 70 8,498 7,087 15,530 9,657 6,782
42 x 24 x 24 92 14,146 11,861 26,042 16,103 11,596
42 x 22 x 29.75 118 18,697 15,751 34,948 21,560 14,957
48 x 22 x 32.5 140 30,251 26,446 41,001 34,498 25,375
54 x 24 x 28 350 36,099 30,945 N/A N/A 28,829
60 x 30 x 32 433 44,200 40,792 N/A N/A 38,469
66 x 30 x 31 627 N/A 48,684 N/A N/A 48,674All Units in Feet 2” Flange Clearance
Hybrid Loose Tube Non-Armored/Coax (O-DN-HY, M-DN-HY) Cables Flange x Drum x Reel Fiber + Coax Hybrid Self Supporting Fiber + Coax Hybrid Traverse Weight (lbs) DN (1-12F) DN (1-12F)
35 x 16.5 x 18 70 4,998 3,791
42 x 24 x 24 109 8,476 6,520
42 x 22 x 29.75 118 11,362 8,703
48 x 22 x 32.5 140 19,262 14,817
54 x 24 x 28 350 22,714 17,282
60 x 30 x 32 433 29,842 22,955
66 x 30 x 31 580 37,946 29,017
72 x 36 x 36 627 44,198 37,863
78 x 36 x 36 758 N/A 44,198 All Units in Feet 2” Flange Clearance
Reel Weights subject to change without notice.
Outside Plant Central Tube Armored (O-CA) Cables Flange x Drum x Reel CA CA CA Traverse Weight (lbs) 2-24 26-48 50-96
35 x 16.5 x 18 70 4,278 3,254 2,409
42 x 24 x 24 109 7,574 5,169 3,833
42 x 22 x 29.75 118 9,786 6,964 5,331
48 x 22 x 32.5 140 16,322 11,700 8,768
54 x 24 x 28 350 18,389 13,532 9,858
60 x 30 x 32 433 24,414 18,068 13,192
66 x 30 x 31 580 31,376 23,067 17,521
72 x 36 x 36 627 41,002 30,430 22,855
78 x 36 x 36 758 51,545 38,278 28,469
84 x 40 x 40 850 N/A 46,761 33,252
88 x 40 x 40 958 N/A 51,545 N/AAll Units in Feet 2” Flange Clearance
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Fiber Optic CablePackaging and Shipping Information
Low-Smoke Zero-Halogen (LSZH) Distribution (Z-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT
2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A
4 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
6 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
8 SU 1,583 3,418 8,294 15,862 N/A 27,646 28,000 N/A N/A N/A N/A N/A N/A
12 SU 1,228 2,626 6,326 12,375 N/A 21,514 28,000 N/A N/A N/A N/A N/A N/A
18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A
24 SU N/A N/A N/A 8,393 N/A 14,595 18,966 28,000 N/A N/A N/A N/A N/A
18 MU N/A N/A N/A N/A 2,115 3,859 5,266 8,695 9,540 12,822 16,857 21,628 27,141
24 MU N/A N/A N/A N/A 1,737 3,271 4,060 6,990 7,885 10,516 13,410 17,120 22,035
36 MU N/A N/A N/A N/A 1,692 3,125 3,919 6,262 7,282 9,536 12,302 15,784 20,524
48 MU N/A N/A N/A N/A 1,365 2,220 3,197 4,750 5,732 7,619 10,116 12,865 15,381
60 MU N/A N/A N/A N/A N/A 2,043 2,655 4,085 4,547 5,963 8,176 10,536 12,816
72 MU N/A N/A N/A N/A N/A 1,669 2,162 3,466 3,864 5,122 6,639 8,431 11,188
Reel Weights subject to change without notice.
Reel Weights subject to change without notice.
Riser-Rated Distribution (R-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT
2 SU 3,553 8,168 20,028 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A
4 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
6 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
8 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
12 SU 1,640 3,525 8,866 16,947 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
18 SU N/A N/A N/A 10,820 N/A 18,657 24,907 28,000 N/A N/A N/A N/A N/A
24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A
18 MU N/A N/A N/A N/A 3,673 6,273 8,058 13,136 15,714 20,784 26,930 28,000 N/A
24 MU N/A N/A N/A N/A 2,529 4,600 6,211 9,912 11,586 15,357 19,768 25,111 28,000
36 MU N/A N/A N/A N/A 2,475 4,531 5,522 9,036 10,625 14,161 18,409 23,479 28,000
48 MU N/A N/A N/A N/A 2,061 3,790 4,728 7,861 8,854 11,710 15,571 20,078 25,397
60 MU N/A N/A N/A N/A 1,699 2,785 3,840 6,154 7,135 9,576 12,361 15,541 19,248
72 MU N/A N/A N/A N/A 1,360 2,215 3,186 4,849 5,707 7,591 10,072 12,815 16,187
96 MU N/A N/A N/A N/A N/A 1,661 2,150 3,443 3,968 5,245 7,340 9,278 11,407
144 MU N/A N/A N/A N/A N/A 1,327 1,713 288 3,341 4,469 5,902 7,327 9,224
Plenum-Rated Distribution (P-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x25 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT
2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A
4 SU 3,050 6,998 17,584 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A
6 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
8 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
12 SU 1,696 3,899 9,444 18,048 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A
18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A
24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A
18 MU N/A N/A N/A N/A 4,679 8,067 10,988 17,918 19,605 26,276 28,000 N/A N/A
24 MU N/A N/A N/A N/A 3,302 6,181 7,968 13,027 14,803 19,637 25,652 28,000 N/A
36 MU N/A N/A N/A N/A 2,845 4,772 6,385 10,820 12,337 16,589 21,158 26,779 28,000
48 MU N/A N/A N/A N/A 2,408 4,023 5,437 8,924 10,466 13,975 18,181 23,227 28,000
60 MU N/A N/A N/A N/A 1,745 3,193 3,982 6,878 7,926 10,562 13,478 16,872 20,721
72 MU N/A N/A N/A N/A 1,461 2,657 3,313 5,488 6,408 8,461 11,067 14,307 17,888
96 MU N/A N/A N/A N/A N/A 1,717 2,208 3,921 4,328 5,874 7,500 9,459 11,621
144 MU N/A N/A N/A N/A N/A 1,612 2,104 3,387 3,757 4,998 6,483 8,484 10,545
F71
Fiber O
ptic C
ab
le Prod
ucts
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Reel Weights subject to change without notice.
Fiber Optic CablePackaging and Shipping Information
Riser, Plenum and LSZH* Simplex (SP) Cables Fiber Size
18x12x12 22x12x12 30x12x12 FT FT FT
1 1.6 19,602 28,000 N/A
1 2.0 14,364 28,000 N/A
1 2.5 9,363 20,848 28,000
1 2.9 6,897 15,824 28,000
* LSZH is only for the 2.5 and 2.9 cables.
Riser, Plenum and LSZH* Zipcord (ZC) Cables Fiber Size 24 x 12 x 19.25 35 x 16.5 x 18 FT FT
2 1.6 28,000 N/A
2 2.0 28,000 N/A
2 2.5 21,983 28,000
2 2.9 15,965 28,000
* LSZH is only for the 2.5 and 2.9 cables.
Riser, Plenum and LSZH* Interconnect (IC) Cables Fiber Size 18x12x12 22x12x12 30x12x12 FT FT FT
2 2.9 6,897 15,824 28,000
All reels calculated using 2” flange clearance
F72
Fib
er O
ptic
Ca
ble
Pro
duct
s
For more information, call Customer Service at 800.982.1708 or 828.324.2200 • Fax 828.328.3400 • [email protected]
Reel Weights subject to change without notice.F73
Fiber Optic CablePackaging and Shipping Information
Reel Dimensions Reels per Layer Layers Cube Size (in.) (l x w x h) Lagging Weight (lbs.) Reel Weight (lbs.) Pallet Weight (lbs.) Total Weight (lbs.)
18 x 12 x 12 5 1 44 x 44 x19 N/A 10 32 82
18 x 12 x 12 5 2 44 x 44 x 32 N/A 10 32 132
18 x 12 x 12 5 3 44 x 44 x 45 N/A 10 32 182
18 x 12 x 12 4 1 36 x 36 x 19 N/A 10 23 63
18 x 12 x 12 4 2 36 x36 x 32 N/A 10 23 103
18 x 12 x 12 4 3 36 x 36 x 45 N/A 10 23 143
22 x 12 x 12 4 1 44 x 44 x 19.25 N/A 12 32 80
22 x 12 x 12 4 2 44 x 44 x 32.5 N/A 12 32 128
22 x 12 x 12 4 3 44 x 44 x 45.75 N/A 12 32 176
24 x 12 x 19.25 1 1 36 X 24 X 30 N/A 17 32 49
30 x 12 x 12 1 1 42 x 42 x 19.25 N/A 22 30 52
35 x 16.5 x 18.5 1 N/A 39 X 25 X 41 60 70 36 166
42 x 22 x 29.75 1 N/A 44 X 40 X 52 189 118 43 350
42 x 24 x 24 1 N/A 44 X 33 X 52 189 109 41 339
48 x 22 x 32.5 1 N/A 51 x 42 x 58 169 140 78 387
54 x 24 x 28 1 N/A 57 x 42 x 64 188 350 78 616
60 x 30 x 32 1 N/A 63 X 45 X 70 215 433 138 786
66 x 30 x 32 1 N/A 69 X 45 X 75 241 580 138 959
72 x 36 x 36 1 N/A 75 X 48 X 82 333 627 197 1157
78 x 36 x 36 1 N/A 81 x 48 x 88 360 758 197 1315
84 x 40 x 40 1 N/A 85 x 52 x 92 387 850 210 1447
88 x40 x 40 1 N/A 91 x 52 x 97 414 958 210 1582
96 x 44 x 40 1 N/A not palletized 450 1125 0 1575
NOTE: Units per container can be limited due to product weight
International Packaging - Weights and Dimensions