17
Products General Details Product Descriptions HomeSelect Guardrail assembly and component details are shown in Figure 44 through 44. General Product Usage ver 5.3 Page 1 of 17 5. Each guardrail system may be installed at maximum spans as indicated in Figure 1, Figure 2, Figure 12, Figure 20, Figure 28, Figure 36, and Figure 43. Each system is rated for a railing height of 42-inches or 36-inches as indicated in Table 1. 1. All guardrails shall be installed in accordance with the manufacturer's installation instructions and the conditions of this PER. A copy of the manufacturer's installation instructions shall be made easily available to the installer. Pei Evaluation Service ® is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated. This product has a Product Evaluation Service Agreement & Follow-up Inspection Service Agreement. This Product Evaluation Report in no way implies warranty for this product or relieves Fiber Composites, LLC of their liabilities for this product. This PER is an official document if it is within one year of the Initial or Re- Approval date. Initial Approval Re-Approved January, 2016 June, 2018 See all Pei ES Listings at: www.p-e-i.com Fiberon ® SymmetrySignature Railing Fiberon Horizon ® Railing Armorguard RegencyWhite Rail Evaluation Report Information Fiber Composites Contact Information: Approved Manufacturing Locations Report Owner Fiber Composites, LLC 181 Random Drive New London, NC 28127 3. Fiberon Symmetry Signature Railings may be used in all construction types where untreated wood is permitted in accordance with Section 1406.3 of the IBC. Fiberon, Veranda, and HomeSelect Guardrails have been tested and evaluated for structural strength to meet design loads and requirements of the building codes listed under the Code Compliance section of this Product Evaluation Report (PER). The approved manufacturing location shown above has an approved Quality Control Manual to manufacture the products. Fiber Composites, LLC has a Product Evaluation Service Agreement with Pei Evaluation Service ® (Pei ES) and a Follow-up Inspection Service Agreement with Progressive Engineering Inc. (Pei ). The manufacturing facility will be audited on a quarterly basis by Pei . 2. All framing, wood posts, beams, joists, stringers and associated connections required to anchor the railing posts are outside the scope of this PER. All framing shall follow applicable codes or be designed by a licensed Engineer. Stairway handrail shall be designed and constructed in accordance with the applicable codes. Fiberon Symmetry Signature assembly and component details are shown in Figure 1 through Figure 8, and Fiberon Horizon assembly and component details are shown in Figure 9 through Figure 16. Fiber Composites, LLC 181 Random Drive New London, NC 28127 4. All guardrail system load tests were performed using 4x4 Douglas Fir or Treated Southern Pine posts. Where alternative lumber species are utilized, the fastener capacity shall be verified by the local code official or a registered design professional as deemed applicable. Armorguard Deluxe Railing Armorguard EnclaveRailing HomeSelectGuardrails 1-800-573-8841 or [email protected] Armorguard Regency White Rail assembly and component details are shown in Figure 17 through 26. Armorguard Enclave assembly and component details are shown in Figure 27 through 33. All guardrail systems covered by this PER are co-extruded MPVC (Mineral-Filled PVC) products manufactured in one of the following Pei ES approved colors: White, Tranquil White, Black, Serene Black, Bronze, Dark Walnut, Simply Brown, Mahogany, Redwood, and Cedar. Veranda ArmorGuard is co-extruded Polyethylene/Wood core with HDPE capstock manufactured in two Pei ES approved colors: Nantucket Gray and Brazilian Walnut. Railing systems consist of the structural components outlined in Table 2 and Table 4 and fasteners outlined in Table 3 and Table 5. Armorguard Classic Railing Armorguard Classic Railing assembly and component details are shown in Figure 34 through 44. Armorguard Deluxe Railing assembly and component details are shown in Figure 34 through 44. PER-15099
Transcript
Page 1: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Products

General Details

Product Descriptions

HomeSelect Guardrail assembly and component details are shown in Figure 44 through 44.

General Product Usage

ver 5.3 Page 1 of 17

5. Each guardrail system may be installed at maximum spans as indicated in Figure 1, Figure 2, Figure 12, Figure 20, Figure 28, Figure36, and Figure 43. Each system is rated for a railing height of 42-inches or 36-inches as indicated in Table 1.

1. All guardrails shall be installed in accordance with the manufacturer's installation instructions and the conditions of this PER. A copyof the manufacturer's installation instructions shall be made easily available to the installer.

Pei Evaluation Service® is an accredited ISO Standard 17065 Product Certifier,accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated. This product has a Product Evaluation Service Agreement & Follow-upInspection Service Agreement. This Product Evaluation Report in no way implieswarranty for this product or relieves Fiber Composites, LLC of their liabilities for thisproduct. This PER is an official document if it is within one year of the Initial or Re-Approval date.

Initial Approval Re-ApprovedJanuary, 2016 June, 2018

See all Pei ES Listings at: www.p-e-i.com

Fiberon® Symmetry™ Signature RailingFiberon Horizon® RailingArmorguard Regency™ White Rail

Evaluation Report InformationFiber Composites Contact Information:

Approved Manufacturing LocationsReport OwnerFiber Composites, LLC181 Random DriveNew London, NC 28127

3. Fiberon Symmetry Signature Railings may be used in all construction types where untreated wood is permitted in accordance withSection 1406.3 of the IBC.

Fiberon, Veranda, and HomeSelect Guardrails have been tested and evaluated for structural strength to meet design loads andrequirements of the building codes listed under the Code Compliance section of this Product Evaluation Report (PER). The approvedmanufacturing location shown above has an approved Quality Control Manual to manufacture the products. Fiber Composites, LLChas a Product Evaluation Service Agreement with Pei Evaluation Service® (Pei ES) and a Follow-up Inspection Service Agreementwith Progressive Engineering Inc. (Pei ). The manufacturing facility will be audited on a quarterly basis by Pei .

2. All framing, wood posts, beams, joists, stringers and associated connections required to anchor the railing posts are outside thescope of this PER. All framing shall follow applicable codes or be designed by a licensed Engineer. Stairway handrail shall be designedand constructed in accordance with the applicable codes.

Fiberon Symmetry Signature assembly and component details are shown in Figure 1 through Figure 8, and Fiberon Horizonassembly and component details are shown in Figure 9 through Figure 16.

Fiber Composites, LLC181 Random Drive

New London, NC 28127

4. All guardrail system load tests were performed using 4x4 Douglas Fir or Treated Southern Pine posts. Where alternative lumberspecies are utilized, the fastener capacity shall be verified by the local code official or a registered design professional as deemedapplicable.

Armorguard Deluxe Railing

Armorguard Enclave™ RailingHomeSelect™ Guardrails

1-800-573-8841 or [email protected]

Armorguard Regency White Rail assembly and component details are shown in Figure 17 through 26. Armorguard Enclaveassembly and component details are shown in Figure 27 through 33.

All guardrail systems covered by this PER are co-extruded MPVC (Mineral-Filled PVC) products manufactured in one of the followingPei ES approved colors: White, Tranquil White, Black, Serene Black, Bronze, Dark Walnut, Simply Brown, Mahogany, Redwood, andCedar. Veranda ArmorGuard is co-extruded Polyethylene/Wood core with HDPE capstock manufactured in two Pei ES approvedcolors: Nantucket Gray and Brazilian Walnut. Railing systems consist of the structural components outlined in Table 2 and Table 4 andfasteners outlined in Table 3 and Table 5.

Armorguard Classic Railing

Armorguard Classic Railing assembly and component details are shown in Figure 34 through 44. Armorguard Deluxe Railingassembly and component details are shown in Figure 34 through 44.

PER-15099

Page 2: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Code & Standard Compliance

Tested to

ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

Page 2 of 17

ASTM D7032 - Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite Deck Boards and GuardrailSystems

PER-15099

Section R301.5 Section R312

Section 1015.5 Section 1015.7

Section R317.4

2015 International Residential Code 2015 International Building Code

Section 1013.3Section 1013.6

Section 1013.4Section 1013.2Section 1013.5 Section 1013.7

2009 International Residential Code 2009 International Building Code

Section 1607.8.1

Section 1015.3

Section 1607.8.1Section 1015.6Section 2612

2012 International Residential Code 2012 International Building CodeSection R312.1Section R301.5

Section R317.4 Section R507.3

Notes:1. Limited to use in all construction types where untreated wood is permitted in accordance with Section 1406.3 of the IBC.

2. All products may be recognized as code compliant in accordance with the 2012 IBC/IRC, 2015 IBC/IRC, 2014 Florida Building Code, 2014Florida Building Code - Residential, and 2013 Abu Dhabi International Building Code (same code sections as 2009 IBC). System specific limitationsare provided in Table 1.

3. Recognition through the 2014 FBC and 2014 FBC-Residential excludes use in High-Velocity Hurricane Zones (HVHZ).

Section 1013 Section 1607.7.1Section R317.4

Section R301.5 Section R312.1 Section 1015.2 Section 1015.4

Railing System Nominal Length Maximum Height Additional LimitationsFiberon Symmetry Signature 6-ft and 8-ft 42-in None

Fiberon Symmetry Signature Stair Railing

6-ft and 8-ft 42-in One- and Two-Family Dwellings

Fiberon Horizon 6-ft and 8-ft 42-in One- and Two-Family Dwellings

Fiberon Horizon Stair Railing3 6-ft and 8-ft 42-in One- and Two-Family DwellingsAmorguard Regency White Rail 6-ft and 8-ft 42-in One- and Two-Family Dwellings

Armorguard Regency Stair Railing3 6-ft 42-in One- and Two-Family DwellingsArmorguard Enclave 6-ft 36-in One- and Two-Family Dwellings

Armorguard Enclave Stair Railing3 6-ft 36-in One- and Two-Family Dwellings

Armorguard Classic1 6-ft and 8-ft 42-in One- and Two-Family Dwellings

Armorguard Deluxe1 6-ft 42-in One- and Two-Family Dwellings

HomeSelect Traditional1 6-ft and 8-ft 42-in One- and Two-Family DwellingsHomeSelect Naturals 6-ft 36-in One- and Two-Family DwellingsHomeSelect Sentry 6-ft 36-in One- and Two-Family Dwellings

2. Fiberon Symmetry Signature guardrail system is limited to a minimum stair angle of 30o and a maximum stair angle of 37o.

3. Fiberon Horizon and Armorguard guardrail systems are limited to a minimum stair angle of 27o and a maximum stair angle of 37o.

1. Armorguard Classic, Armorguard Deluxe, and HomeSelect Traditional guardrail systems are limited to a height of 36-inches when colonial balusters are used. See Figure 44 for HomeSelect baluster details.

Notes:

Table 1 - Individual Railing System Additional Code Limitations

Page 3: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 3 of 17

PER-15099

System Component

Fiberon Symmetry Signature

Fiberon Horizon Armorguard

Regency WhiteArmorguard

Enclave

Top RailCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Top ReinforcementExtruded 6063-T6

Aluminum H-Channel

-- -- --

Top BracketHylon N1000HL

(Nylon)Grade 304 Stainless

SteelGrade 304 Stainless

Steel or NylonGrade 304 Stainless

Steel or Nylon

Bottom RailCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Bottom Rail BracketHylon N1000HL

(Nylon)Grade 304 Stainless

SteelGrade 304 Stainless

Steel or NylonGrade 304 Stainless

Stee or Nylon

Post Sleeve/WrapCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded Cellular PVC

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

3/4" Diameter Extruded 6063-T6

Aluminum

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

Crush BlocksCo-Extruded Cellular

PVCCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Crush Block Holder Nylon -- -- --

Table 2 - Fiberon & Armorguard Railing Systems Component Material Specifications

Baluster Options

System ConnectionFiberon Symmetry

SignatureFiberon Horizon

Armorguard Regency White

Armorguard Enclave

Top Rail to Bracket #10x5/8" Screws#10x3/4" SS Flat

Head Screws2#10x3/4" SS Flat

Head Screws#10x3/4" SS Flat

Head ScrewsTop Rail Cap to

Sub-Rail -- -- -- --

Top Bracket to Post #10x2-1/2" Screws#10x1-1/4" SS Flat

Head Screws3#10x1-1/4" SS Flat

Head Screws#10x1-1/4" SS Flat

Head Screws

Top Rail to Baluster#8x1-1/2" Flat Head

ScrewsPVC Baluster

DaggersBalusters Pass Through Rail

Balusters Pass Through Rail

Top Rail to Reinforcement

#10x1-7/8" Screws -- -- --

Bottom Rail to Bracket

#10x5/8" Screws#10x3/4" SS Flat

Head Screws#10x3/4" SS Flat

Head Screws#10x3/4" SS Flat

Head ScrewsBottom Bracket to

Post#10x2-1/2" Screws

#10x1-1/4" SS Flat Head Screws

#10x1-1/4" SS Flat Head Screws

#10x1-1/4" SS Flat Head Screws

Bottom Rail to Baluster

#10x1-1/2" ScrewsPVC Baluster

DaggersBalusters Pass Through Rail

Balusters Pass Through Rail

Notes:

1. Fastening requirements are valid for both level and stair rail applications unless noted otherwise.

2. For 8-ft Horizon stair top rail to bracket connection, use #10x1" SS Flat Head Screws and 1/8" diameter pre-drill.

3. For 8-ft Horizon stair top rail to post connection, use #10x2" SS Flat Head Screws and 1/8" diameter pre-drill.

Table 3 - Fiberon & Armorguard Railing Systems Fastener Requirements1

Page 4: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 4 of 17

PER-15099

System Component

Armorguard Deluxe

HomeSelect Traditional

Armorguard Classic

HomeSelect SentryHomeSelect

Naturals

Top RailCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Top Reinforcement

Top Bracket

PVC Socket - Polycarbonate

Dovetail keyways with Pan Type A Grade 304 SS

PVC Socket - Polycarbonate

Dovetail keyways with Pan Type A Grade 304 SS

PVC Socket - Polycarbonate

Dovetail keyways with Pan Type A Grade 304 SS

PVC Socket with Pan Type A Grade

304 SS

Grade 304 Stainless Steel

Bottom RailCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Bottom Rail Bracket PVC PVC PVC PVCGrade 304 Stainless

Steel

Post SleeveCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

PVC (Colonial Balusters Only)

PVC (Colonial Balusters Only)

PVC (Colonial Balusters Only)

PVC (Colonial Balusters Only)

PVC (Colonial Balusters Only)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

3/4" Diameter G60 Steel Tube

(45,000-psi Yield)

Crush BlocksCo-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Co-Extruded MPVC (Mineral-Filled PVC)

Table 4 -HomeSelect & Armorguard Railing Systems Component Material Specifications

Baluster Options

System ConnectionArmorguard

DeluxeHomeSelect Traditional

Armorguard Classic

HomeSelect SentryHomeSelect

Naturals

Top Rail to Bracket#10x1" SS Pan Head Screws

#10x1" SS Pan Head Screws

#10x2-1/2"" SS Pan Head Screws

#10x1" SS Pan Head Screws

#10x1" SS Flat Head Screws

Top Bracket to Post#10x1-1/2" SS Pan

Head Screws#10x1-1/2"" SS Pan

Head Screws#10x1-1/2"" SS Pan

Head Screws#10x1-1/2" SS Pan

Head Screws#10x2" SS Pan Head Screws

Top Rail to BalusterBalusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Bottom Rail to Bracket

Slip Fit Only - No Fastener

Slip Fit Only - No Fastener

Slip Fit Only - No Fastener

Slip Fit Only - No Fasteners

#10x1" SS Flat Head Screws

Bottom Bracket to Post

#10x1-1/2" SS Pan Head Screws

#10x1-1/2" SS Pan Head Screws

#10x1-1/2" SS Pan Head Screws

#10x1-1/2" SS Pan Head Screws

#10x2" SS Flat Head Screws

Bottom Rail to Baluster

Balusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Balusters Pass Through Rail

Table 4 -HomeSelect & Armorguard Railing Systems Component Material Specifications

Page 5: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Fiberon Symmetry Signature Railing Figures

Page 5 of 17

PER-15099

Page 6: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 6 of 17

PER-15099

Page 7: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Fiberon Horizon Railing Figures

Page 7 of 17

PER-15099

Page 8: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 8 of 17

PER-15099

Page 9: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Armorguard Regency White Rail Figures

Page 9 of 17

Figure 18 - Armorguard RegencyTop & Bottom Rail

PER-15099

Page 10: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 10 of 17

PER-15099

Figure 22 - Armorguard Regency Rail-to-Post Stair Railing Metal Bracket

Page 11: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Armorguard Enclave Railing Figures

Page 11 of 17

PER-15099

Page 12: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 12 of 17

PER-15099

Page 13: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Armorguard & HomeSelect Railing Figures

Page 13 of 17

PER-15099

Page 14: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 14 of 17

PER-15099

Page 15: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Page 15 of 17

PER-15099

Page 16: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Product Labeling

1. The Guardrail name

2. Date Code

3. Manufacturer Name, Logo or Website

4. This PER Number & Pei ES Name or Logo

5. Guardrail Performance & Use Limitations (Indicate ASTM D7032 Compliance)

Acceptable Evaluation Marks

Page 16 of 17

The Guardrail Systems must be labeled with at least the following information:

PER-15099

Page 17: Fiberon Railing - Progressive Engineering Inc · 2019-07-09 · Product Documentation A SDS for PVC Compound Pellets - Dated: 5/21/2015 A test report 2019-6012(A) - Guardrail test

Product Documentation

A SDS for PVC Compound Pellets - Dated: 5/21/2015

A test report 2019-6012(A) - Guardrail test on Fiberon Armorguard Classic Guardrail System - Dated: 4/2/2019

Page 17 of 17

A Test Report No. E6227.01-119-19 - ASTM D 7032-08 Test for Horizon Mission PVC Capped, Mineral-Based Composite GuardrailSystem - Dated: 10/2/2015

Armorguard Enclave Railing Installation Instructions - VER-0065-PKG - Dated: 2/2014

Fiberon Horizon Rail Installation Instructions - FIB-0329-LIT - Dated: 2/2017

Armorguard Regency Railing Installation Instructions - VER-0020-LIT - Dated: 8/2015

A Product Evaluation Service Agreement between Pei Evaluation Service® and Fiber Composites, LLC

A Follow-up Inspection Service Agreement between Progressive Engineering Inc. and Fiber Composites, LLC

A Fiberon Quality Control Manual - Dated: 3/20/2018

A MSDS for Vinyl Resin Compounds - Dated: 1/13/2012

Fiberon Symmetry Signature 6-ft and 8-ft Installation Instructions - FIB-0344-LIT - Dated: 11/2017

A Test Report No. C7840.01-119-19 - ASTM D 7032-08 Test for HomeSelect Classic/Deluxe/Traditional PVC Capped, Mineral-BasedComposite Guardrail Systems - Dated: July 16, 2014

A Test Report No. 74487.01-119-19 - ASTM D 7032-04 and ASTM D 6109-05 Tests for Fiberon Horizon Regency Composite RailSystem - Dated: April 7, 2010

A Pei Test Report No. 2017-6235(A) - ASTM D7032 Guardrail Concentrated Load Tests on an 8' Veranda Regency Railing System and6' Stair Guardrail with UV Exposed Nylon Brackets - Dated: 6/12/2018.

A Test Report No. 3646.01-119-19 - ASTM D 6109-05 for PVC Capped, Mineral-Based Composite Guardrail System Home DepotVeranda Regency - Dated: February 16, 2015

Armorguard Classic Railing Installation Instructions - FHS-0003-LIT - Dated: 5/2015

Armorguard Deluxe/Traditional Railing Installation Instructions - FHS-0002-LIT - Dated: 5/2015

HomeSelect Sentry Railing Installation Instructions - FHS-0001-LIT - Dated: 5/2015

A Test Report No. C8627.01-119-19 - ASTM D 7032-08 Test for HomeSelect Naturals PVC Capped, Wood-Plastic CompositeGuardrail System - Dated: 3/21/2014

A Pei Test Report No. 2017-0380(A) - ASTM D7032 Guardrail Concentrated Load Tests on a 8' HomeSelect Traditional Railing Systemwith new LMT Keyway Brackets - Dated: 4/12/2017

A Pei Test Report No. 2017-0380(B) - ASTM D7032 Guardrail Concentrated Load Tests on a 6' HomeSelect Deluxe Railing Systemwith new LMT Keyway Brackets - Dated: 4/13/2017

A Pei Test Report No. 2017-0380(C) - ASTM D7032 Guardrail Concentrated Load Tests on a 6' HomeSelect Sentry Railing System -Dated: 4/11/2017

A Pei Test Report No. 2017-0380(D) - ASTM D7032 Guardrail Concentrated Load Tests on a 8' HomeSelect Classic Railing Systemwith new LMT Keyway Brackets - Dated: 4/12/2017

A Test Report No. D7452.01-119-19 - ASTM D 1761-06, ASTM D 6109-05, and ASTM D 7032-08 Tests for PVC Capped, Mineral-Based Composite Guardrail Systems Home Depot Veranda Enclave and Veranda Regency - Dated: August 29, 2014

A Test Report No. 92465.01-119-19 - ASTM D 7032-07 Test for Horizon Series and Professional Series Composite Guardrail Systemswith Fortress Iron Balusters - Dated: December 28, 2009

A Test Report No. 77584.01-119-19 - ASTM D 7032-04 Test for Composite Baluster and PVC Dagger with WeatherBest Provincial andWeatherBest Mission Guardrail Systems - Dated: January 7, 2009

A Test Report No. E3648.01-119-19 - ASTM D 1761-06 and ASTM D6109-05 for PVC Capped, Mineral-Based Composite GuardrailSystem for Horizon Mission - Dated: July 9, 2015 - Revised: September 16, 2015

An Engineering Comparison Letter - MPVC Core vs. Wood Composite Core for Horizon Guardrail System - Dated: April 25, 2016

A Test Report No. D9734.01-119-19 - ASTM D 1761-06, ASTM D6109-05, and ASTM D7032-08 for Home Depot Veranda ArmorGuardComposite Guardrail System - Dated: November 18, 2014

A Pei Test Report No. 2016-765 (A) - ASTM D7032 Guardrail Infill Load Test on a 8' Symmetry Rail System with Round AluminumBalusters with a 0.075" Thick Aluminum Rail Reinforcement - Dated: 6/7/2016 (Revised: 8/24/2016)

A Pei Test Report No. 2016-765 (B) - ASTM D7032 Ultraviolet Resistance Test on Black Fiberon Symmetry MPVC Railing and CellularPVC Baluster Components - Dated: 9/6/2016

A Pei Test Report No. 2016-1431(A) - ASTM D7032 Guardrail Test on Various Fiberon, HomeSelect, and ArmorGuard Railing Systemsto Evaluate Design Changes - Dated: 10/18/2016

HomeSelect Natural Railing Installation Instructions - FHS-0004-LIT - Dated: 4/2013

A Test Report No. 15-236 - ASTM D 7032-10a Flexural Tests (Control & After UV Exposure) on Fiberon Symmetry Balusters (White) -Dated: October 13, 2015

A Test Report No. C7840.02-121-24 - ASTM E84-09 Surface Burning Characteristics Test for HomeSelect® Square Balusters - Dated:October 22, 2013

A Test Report 2019-6011 - Guardrail test on Fiberon Symmetry Signature Guardrail System - Dated-4/1/2019

PER-15099


Recommended