12.57312.5734.888
40.248
5.955 12.573 12.573
40.23440.234
40.234
234°57'20"234°57'20"
234°57'20"
323°26'10"
54°57'20" 54°57'20" 54°57'20"
144°57'20"
144°57'20"
144°57'20"
2RP619288
3RP602024
1RP602024
GEO
RG
E LANE
338
(From R
ecords)
EHWS
Elec BoxSL 9.3
(From Records)
(From R
ecords)
(From Records)
SW
SW Pit
S L 9.45
Kb Kb O
IL
9.23
9.27
9.37
12.2212.4
12.39
859
9.33
9.25
9.25
9.25
9.09
9.11
9.2
9.22
9.18 9.05
9.18
9.04
9.1
9.089.039.219.27
9.25
9.259.17
9.23
9.349.299.299.349.36
9.439.36
9.449.41
9.4
9.51
9.529.56
9.499.38
9.49.469.479.4
9.49
9.48 9.329.36
9.29
9.32
9.48
9.489.48
9.299.21
11.77
12.2112.29
12.4912.4
8.848.71 88.668.78
8.78.72
8.798.6788 64
8.77
99.21
9
9.04
9
8.96
8.71
8.718.698.67
8.988.958.97
9.089.059.08
9.189.169.18
9.29.189.18
9.21
9.279.279.279.36
9.39 9
9
9.34
9.25
9.12
8.93
8.94
8.898.88
8.74
8.94
8.98
9.02
9.04
8.98
9.09
8.94
9.06
9.09
9.13
9.18
9.01
9.17
9.21
9.2
9.2
9.52
9.51
9.28
Steps
Conc
Path
c Path
Conc S poon D
rainD
rain
ve way
FL 9.48
FL 9.59
Conc Kerb & Channel
Gate
Gate
Gate
GI Shed onFL9.51
Conc Slab
Lowset BrickBuilding
FL9.48/FL9.59
Lowset Block
Retail BuildingFL9.44
Grass Verge
Vacant Land
Sew MHSL 9.30
Sew MHSL 9.16
IL 7. 61
IL 7.57
IL 8.51100
50
150
Sew IO
S L 9.29
Sew IO x 2SL 9.35
Records )
(From R
ecords)
(Unable to open)
EXISTING TREES TO BE REMOVED SHOWN DASHED
EXISTING SHED TO BE DEMOLISHED SHOWN DASHED
PROPOSE NEW LOCATION OF SEWERAGE LINE APPROX. SHOWN BLUE
EXISTING BUILDING TO BE DEMOLISHED SHOWN DASHED
EXISTING TREES TO BE REMOVED SHOWN DASHED
S S S S S
SS
S
PROPOSED RELOCATION POSITION OF SEWER MANHOLE
PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION
DENHAM ST
OSD TANK BY STORMWATER ENG. DETAILS
GENERAL NOTES - DEMOLITION:• UNDERTAKE OTHER DEMOLITION WORK AS REQUIRED, IN ORDER
TO PRODUCE THE FINAL BUILDING AS ILLUSTRATED IN THESE DRAWINGS
• DURING DEMOLITION, ENSURE THAT ALL NECESSARY HOARDINGS, SCREENS, PROPPING & PROCEDURES ARE CARRIED OUT, AS REQUIRED UNDER THE WORKPLACE HEALTH & SAFETY ACT AND TO PROVIDE STRUCTURAL ADEQUACY
• WHERE JUNCTIONS/ ELEMENTS BETWEEN DEMOLISHED AND REMAINING ITEMS AR TO REMAIN, THESE AREAS ARE TO BE MADE GOOD.
• WHERE PRACTICAL, RETAIN REMOVED MATERIALS FOR RE-USE, PARTICULARLY ITEMS LISTED AS SUCH ON THE DRAWINGS. STORE ITEMS FOR RE-USE AWAY FROM THE ELEMENTS, OR AS APPROPRIATE
• IF ASBESTOS BASED MATERIALS ARE ENCOUNTERED, SPECIALIST REMOVERS MUST BE ENGAGED, AND ALL OTHER PERSONS REMOVED FROM SITE AND ALL NEIGHBOURING PROPERTIES TO BE INFORMED
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
As indicated
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02.rv
t11
/06/20
19 9:
09:44
AM
DR NICHOLAS MANNING
A0001
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
EXISTING SITE &DEMOLITION PLAN
12
1 : 200
EXISTING SITE & DEMOLITION PLAN1
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
EOEOEOEOEUEUEUEUFOFOFOFOGGGGSSSS
SWSWSWSWTTTTWWWW
EXISTING TREES TO BE DEMOLISHED SHOWN DASHED
PROPOSED MEDICAL CENTREAREA: 400m²
SHARED ZONE
0209 08 07 06 05 04 03
2400 2600 2600 2700 2600 2600 2600 2600 2600 2600
01
10
11
5800
EXISTING BUILDING TO BE DEMOLISHED SHOWN DASHED
1000
2600 24005400
TURNINGBAY
DR SPACE(COVERED)
+S.F.L RL: 9.450
+S.F.L RL: 9.465
2400
5400
5400
3000 x 3000 PROHIBITED PLANTING AREA TO ALLOW FOR SAFE ENTRY AND EXIT FROM GEORGES LANE SHOWN HATCHED
PROPOSE NEW LOCATION OF SEWERAGE LINE APPROX. SHOWN BLUE
BIN
STO
RAG
E AR
EA
PROPOSED 1600mm HIGH SANDSTONE PIER AND "LEVEL SPEAR" FENCE TO PRIMARY AND SECONDARY BOUNDARIES FOR SAFETY AND VISIBILITY WITH AUTOMATED SLIDING "LEVEL SPEAR" GATE AT PATIO AND DRIVEWAY ENTRIES
1200
1700
1269
8
6298
1162
S S S S S
SS
S
PROPOSED RELOCATION POSITION OF SEWER MANHOLE
PROPOSED AUTO SECURITY SLIDING GATE
PROPOSED 1600mm HIGH SECURITY AUTO SLIDING GATES
6096
2000L SLIMLINE RAINWATER TANK
2000L SLIMLINE RAINWATER TANK
2802
3401
AREA SHOWN HATCHED TO BE MULCHED
DENHAM ST
PEDESTRIAN ACCESS ENTRY CROSS OVER
ALLOW TO SEAL BITUMEN
LOCATION OF A/C UNIT
PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION
+F.F.L. RL: 9.50
METAL AWNING ROOF OVER CARSPACES SHOWN DASHED
OSD TANK BY STORMWATER ENG. DETAILS
PROPOSED STORMWATER PITS TO STORMWATER ENGINEER'S DETAILS.
DEVELOPMENT CALCULATION:SITE AREA
LOT 1LOT 2LOT 3TOTAL SITE AREA
SITE COVER & LANDSCAPE CALCULATION
MAXIMUM SITE COVERAGE (80%)
PROPOSED SITE COVER AREA PROPOSED LANDSCAPED AREA
PROPOSED MEDICAL CENTRE (incl. medical rooms, waiting area, garage & wet areas)PROPOSED MEDICAL CENTRE(excl. waiting area, garage & wet areas)
= 218m²= 506m²= 506m²= 1230m²
= 983.88m²
= 449m² COMPLIES= 223.79m² COMPLIES
= 449m²
= 300m²
SETBACKS
FRONT SETBACK(avg. front setback)SIDE SETBACK GROUND FLOORREAR SETBACK
HEIGHT RESTRICTION 12m MAX.
= 3.50m COMPLIES
= 2.7 & 5.50m COMPLIES= 14.2m COMPLIES
= 5.83m COMPLIES
ELECTRICITY OVERHEADELECTRICITY UNDERGROUNDFIBRE OPTICGASSEWERSTORMWATERTELSTRAWATER
SERVICES LEGEND:
TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
As indicated
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
09:48
AM
DR NICHOLAS MANNING
A0002
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PROPOSED SITE PLAN
12
1 : 200
PROPOSED SITE PLAN1
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
200
100
- SLOPE LENGHT 50M MAX- SLOPE GRAIDENT 1:2 MAX- DRAINAGE AREA 0.5HA MAX
WIRE OR STEEL MESH
GEOTEXTILE FILTER FABRIC
DISTURBED AREA
UNDISTURBED AREA
min length 15 m
0.2 mmin. width 3 m
berm (0.3 m min. high)
existing roadwaydirected to sediment traprun off from pad
fabricgeotextile
50-75 mmgravel
construction site
SHARED ZONE
0209 08 07 06 05 04 03
01
10
DR SPACE
INSTALL APPROVED EROSION AND SEDIMENT CONTROL BARRIER/FENCE (FULL EXTENT TO BE DETERMINED ON SITE TO ENSURE 100% CAPTURE)
TEMPORARY SITE ENTRY/ EXIT FENCE
WASTE BINS FOR TIMBER. BRICK, TILE, CONCRETE, METAL AND MIXED WASTE
STOCKPILING OF "STRIPPED" TOP SOIL AND EXCAVATED MATERIAL TO BE ADEQUATELY PROTECTED WITH GEOTEXTILE MATERIAL. SILT FENCES SHOULD BE PROVIDED IF ASSISTANCE IS NEEDED IN CONTAINING AND SEPARATED STOCKPILES
DENHAM ST
PROPOSED FILL TO 310mm BELOW F.L. 9.50m
PROPOSED FILL TO 310mm BELOW F.L. 9.45m
PROPOSED FILL TO 310mm BELOW F.L. 9.465m
ABBREVIATION:AJ ARTICULATION JOINTBSN BASINDP DOWNPIPESFW FLOOR WASTEHP HOT PLATERH RANGEHOODREF REFRIGERATORSHR SHOWERTUB LAUNDRY TUBVB VANITY BASINWC WATER CLOSETWM WASHING MACHINESD SMOKE DETECTOR
HARDWIRED TO MAINTRH TOILET ROLL HOLDERDTR DOUBLE TOWEL RAILTH TOWEL HOOKMH MAN HOLE
SEDIMENT RUN-OFF CONTROL DURING EARTHWORKS:THE CONTRACTOR SHALL INSTALL AND MAINTAIN SOIL EROSION AND SEDIMENT CONTROL MEASURES GENERALLY IN ACCORDANCE WITH GUIDELINES OF THE NEW SOUTH WALES SOIL CONSERVATION SERVICE AND AS NESASSARY TO PREVENT RUN OFF FROM THE SITE OF ANY SEDIMENT RESULTING FROM HIS WORKS ALL MEASURES ARE TO COMPLY WITH THE REQUIREMENTS OF THE APPROVING COUNCIL TRUCKS AND VEHICLES LEAVING THE SITE ARE NOT TO SPREAD SPOIL ONTO THE ROADWAY OR ALLOW SPOIL TO ENTER THE STORMWATER SYSTEM. ALL DISTURBED GROUND AREAS AND STOCKPILES OF EXCAVATED OR IMPORTED MATERIAL IS TO BE STABILIZED WITHIN 48 HOURS. DUST IS TO BE SUPPRESSED BY WATERING
WASTE LEGEND:BRICK,TILE,CONCRETE DISPOSAL BIN 3 CUBIC METRESTIMBER DISPOSAL BIN 3 CUBIC METRES
MIXED WASTE DISPOSAL BIN 3 CUBIC METRESMETALS DISPOSAL BIN 3 CUBIC METRES
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
As indicated
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
09:51
AM
DR NICHOLAS MANNING
A0003
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PROPOSED CUT & FILL,WASTE & SITEMANAGEMENT PLAN(DURINGCONSTRUCTION)
12
1 : 200
PROPOSED CUT & FILL, WASTE & SITE MANAGEMENT PLAN - DURINGCONSTRUCTION
1REV. DESCRIPTION BY DATE
8 DRAFT DA ISSUE - MINORCHANGES
HC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
SHARED ZONE
0209 08 07 06 05 04 03
01
10
11
3500
TURNINGBAY
DR SPACE
+S.F.L RL: 9.450
+S.F.L RL: 9.465
+S.F.L RL: 9.505
BIN
STO
RAG
E AR
EA
S S S S S
SS
S
PROPOSED RELOCATION POSITION OF SEWER MANHOLE
PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION
OSD TANK BY STORMWATER ENG. DETAILS
600M TO CBD ROCKHAMPTON
1160M TO ROCKHAMPTON HOSPITAL
PROXIMITY TO PLACES OF SIGNIFICANT:
1000M TO ROCKHAMPTON TRAIN STATION
3400M TO STOCKLAND ROCKHAMPTON SHOPPING CENTRE
WINTER - COLD BREEZE
SPRING - EASTERLY
BREEZE
SUMMER - SOUTH
BREEZE
WINTER SUNSUMMER SUN
SUNRISE
SUNSET
EXIS
TING N
ATURAL
SIT
E FA
LL
DENHAM ST
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 200
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
09:53
AM
DR NICHOLAS MANNING
A0004
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PROPOSED SITEANALYSIS
12
1 : 200
PROPOSED SITE ANALYSIS1
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
EOEOEOEOEUEUEUEUFOFOFOFOGGGGSSSS
SWSWSWSWTTTTWWWW
1
A3001
1
A3001
DOCTOR'SSPACE
1550
OVE
RAL
L
2403
6
OVERALL
21823
2802
5500
TREATMENT AREAVINYL FINISH5.05 x 15.5m OFFICE
CARPET FINISH3.90 x 4.55m ADMIN
CARPET FINISH2.03 x 4.56m
RECEPTIONCARPET FINISH3.34 x 3.96m
CONS - 2VINYL FINISH4.01 x 4.0m
CONS - 1VINYL FINISH4.01 x 4.0m
STERILISATIONVINYL FINISH3.80 x 3.39m
DIG LABVINYL FINISH1.89 x 1.93m
LABCARPET FINISH2.9 x 4.20m
GARAGE - 2CONC. FINISH2.99 x 6.0m
GARAGE - 1CONC. FINISH3.96 x 6.0m
PLANT ROOM
PROCEDURE/ SURG - 1VINYL FINISH3.90 x 3.90m
SURG - 2VINYL FINISH3.50 x 3.90m
STAFF WCTILE FINISH1.79 x 1.72m
KIDS AREACARPET FINISH4.20 x 2.50m
ACCESSIBLE W.CTILE FINISH2.10 x 2.70m
WCTILE FINISH2.04 x 0.90m
DR'S OFFICECARPET FINISH2.30 x 2.98m
OPG/ CEPHVINYL FINISH1.66 x 1.63m
STAFFVINYL FINISH3.49 x 3.24
WAITING AREAVINYL FINISH4.20 x 9.27m
PATIOTILE FINISH7.93 x 4.26m
SIGN
AGE
KITCHENVINYL FINISH3.60 x 4.77m
7550 11188 3086
2875 2875 2875 2875 2875 7449
1200
5166
1236
853
00
OVE
RAL
L
2403
4
RAM
P 1:
14
3.77 x 1.90m
3.77 x 1.90m
3.77 x 1.90m
3.77 x 1.90m
3.77 x 1.90m
3.77 x 1.90m
BIN
STO
RAG
E AR
EA
+S.F.L RL: 9.465
+RL: 9.45
STORAGE
STORAGE
STO
RAG
E
CUPBOARD
2
A3001
2
A3001
PHOTOWALL (WITH LIGHTBOX)
SCREEN
MAGAZINE RACK
VENDING MACHINE
VENDING MACHINE
1500
mm
H
IGH
WA
LL15
00m
m
HIG
H W
ALL
1500
mm
H
IGH
WA
LL15
00m
m
HIG
H W
ALL
1500
mm
H
IGH
WA
LL
TV
TV
TV
GATE
GATE
A/C UNIT
2,000L R.W.T
2,000L R.W.T
PLANTER
PLANTER
+RL: 9.25
+RL: 9.43
+RL: 9.20+F.F.L. RL: 9.50
1
3710
TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.
ABBREVIATION:AJ ARTICULATION JOINTBSN BASINDP DOWNPIPESFW FLOOR WASTEHP HOT PLATERH RANGEHOODREF REFRIGERATORSHR SHOWERTUB LAUNDRY TUBVB VANITY BASINWC WATER CLOSETWM WASHING MACHINESD SMOKE DETECTOR
HARDWIRED TO MAINTRH TOILET ROLL HOLDERDTR DOUBLE TOWEL RAILTH TOWEL HOOKMH MAN HOLE
ELECTRICITY OVERHEADELECTRICITY UNDERGROUNDFIBRE OPTICGASSEWERSTORMWATERTELSTRAWATER
SERVICES LEGEND:
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:00
AM
DR NICHOLAS MANNING
A1101
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PROPOSED FLOORPLAN
12
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
3500
12°
20°
20° 20°
12°12°
3°
5°
SELECTED COLORBOND ROOF SHEETING
SELECTED FASCIA, GUTTER AND DOWNPIPES
5°
2°
METAL AWNING ROOF OVER CARSPACES WITH SELECTED COLORBOND ROOF SHEETING
DENHAM ST
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 200
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:02
AM
DR NICHOLAS MANNING
A1102
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PROPOSED ROOF PLAN
12
1 : 200
PROPOSED ROOF PLAN1
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
DOCTOR'SSPACE
SIGN
AGE
+S.F.L RL: 9.505
+S.F.L RL: 9.465
+RL: 9.45
12
12
STORAGE
STORAGE
STO
RAG
E
CUPBOARD
AREA CALCULATION:
PROPOSED MEDICAL AREA 300m²
PROPOSED WET AREAS 12.5m²
PROPOSED WAITING AREA 85.3m²
TOTAL 449m²
PROPOSED GARAGE & PLANT 51.2m²
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:08
AM
DR NICHOLAS MANNING
A1103
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
AREA DIAGRAM
12
1 : 100
AREA DIAGRAM1
REV. DESCRIPTION BY DATE9 DRAFT DA ISSUE & CONSULTANT
COORDINATIONSP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
GROUND FLOOR
9.50
GF CEILING
12.60
BOU
ND
ARY
BOU
ND
ARY
RIDGE RL: 14.91
RIDGE RL: 14.06
SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN
SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING
SELECTED COLORBOND ROOF SHEETING
SELECTED 'LEVEL SPEAR' ANDSANDSTONE PIER FENCE AND SLIDINGGATE TO PATIO AND DRIVEWAY ENTRIES
TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS SELECTED ALUMINIUM POWDERCOATED
FRAMED WINDOWSSELECTED TIMBER FRAMED DOOR ANDGLAZED WINDOWS
SELECTED FACEBRICK
SELECTED METAL FASCIA AND GUTTERS
OVE
RAL
L BU
ILD
ING
HEI
GH
T
5413
PROPOSED 1600mm HIGH AUTO SLIDING GATES
3100
MEDICAL CENTRE SIGNAGE
GROUND FLOOR
9.50
GF CEILING
12.60
3100
BOU
ND
ARY
BOU
ND
ARY
2450
SELECTED 'LEVEL SPEAR' ANDSANDSTONE PIER FENCE AND SLIDINGGATE TO PATIO AND DRIVEWAY ENTRIES
TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS
SELECTED COLORBOND ROOF SHEETING
SELECTED METAL FASCIA AND GUTTERS
SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOINSELECTED ALUMINIUM POWDERCOATED
HIGHLIGHT WINDOWSELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS
RIDGE RL: 14.91
RIDGE RL: 14.06SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING
SELECTED FACEBRICK
1411
PROPOSED 1600mm HIGH AUTO SLIDING GATE
METAL AWNING ROOF OVER CARSPACES
CARPORT
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:18
AM
DR NICHOLAS MANNING
A2001
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
ELEVATIONS 1
12
1 : 100
SOUTH EAST ELEVATION1
1 : 100
NORTH EAST ELEVATION2
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
GROUND FLOOR
9.50
GF CEILING
12.60
3100
BOU
ND
ARY
BOU
ND
ARY
RIDGE RL: 14.91RIDGE RL: 14.74
RIDGE RL: 14.06
RIDGE RL: 12.65
RIDGE RL: 13.55
OVE
RAL
L BU
ILD
ING
HEI
GH
T
5433
SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN
SELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS
SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN
SELECTED COLORBOND ROOF SHEETING
SELECTED FACEBRICK
TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS
SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING
DOCTOR'S CAR SPACE
2,000L SLIMLINE RAINWATER TANK
2,000L SLIMLINE RAINWATER TANK
CARPORT
METAL AWNING ROOF OVER CARSPACES
GROUND FLOOR
9.50
GF CEILING
12.60
3100
BOU
ND
ARY
BOU
ND
ARY
RIDGE RL: 14.91 RIDGE RL: 14.74
RIDGE RL: 13.55
SELECTED COLORBOND ROOF SHEETING
SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING
SELECTED METAL FASCIA AND GUTTERS
TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS
SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN SELECTED ROLLER PANEL DOOR
SELECTED FACEBRICK
SELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS
400MM HIGH SANDSTONE BAND AROUND PERIMETER OF MEDICAL CENTRE
OVE
RAL
L BU
ILD
ING
HEI
GH
T'
5433
DOCTOR'S CAR SPACE
BIN STORE
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:29
AM
DR NICHOLAS MANNING
A2002
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
ELEVATIONS 2
12
1 : 100
SOUTH WEST ELEVATION2
1 : 100
NORTH WEST ELEVATION1
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
GROUND FLOOR
9.50
GF CEILING
12.60
WAITING AREAACCESSIBLE W.C
OPG/ CEPHSTERILISATIONTREATMENT AREA
BOU
ND
ARY
BOU
ND
ARY
RAKED CEILING WITH EXPOSED RAFTERS TO RECEPTION AND WAITING AREA
INTERNAL WALLS LINED WITH 10mm PLASTERBOARD WITH SELECTED PAINT FINISH
250mm EXTERNAL BRICK VENEER WALL CONSTRUCTION
COMPACTED FILL TO STRUCTURAL ENGINEER'S DETAILS SHOWN HATCHED
CONCRETE SLAB AND FOOTINGS TO STRUCTURAL ENGINEER'S DETAILS
TRUSS ROOF CONSTRUCTION TO MANUFACTURER'S SPECIFICATIONS
SELECTED METAL FASCIA AND GUTTERS
SELECTED COLORBOND ROOF SHEETING
CEILING LINING TO UNDERSIDE OF TRUSS BOTTOM CHORD
INSULATION TO EXTERNAL WALLS
INSULATION TO CEILING
3100
TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.
GROUND FLOOR
9.50
GF CEILING
12.60
WAITING AREAKIDS AREAPATIO
CONCRETE SLAB AND FOOTINGS TO STRUCTURAL ENGINEER'S DETAILS
TRUSS ROOF CONSTRUCTION TO MANUFACTURER'S SPECIFICATIONS
SELECTED COLORBOND ROOF SHEETING
RAKED CEILING WITH EXPOSED RAFTERS TO RECEPTION AND WAITING AREA
20° 20°
3°
COMPACTED FILL SHOWN HATCHED
3100
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:35
AM
DR NICHOLAS MANNING
A3001
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
SECTIONS
12
1 : 100
SECTION A-A1
1 : 100
SECTION B-B2
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
EXTERNAL FINISHES SCHEDULE:
MAIN EXTERNAL WALL - BRICKWORK -AUSTRALCOLOUR: TOPAZ OR SIMILAR
SANDSTONE BAND AND QUOINSCOLOUR: BROWN YELLOW OR SIMILAR
ROOF - COLORBOND STEELCOLOUR: MONUMENT OR SIMILAR
GARAGE DOOR - ALUMINIUM PRESSED METAL - COLORBOND COLOUR: SHALE GREY - PLAIN
FASCIA & DOWNPIPES - ALUMINIUM/ PRESSED METALCOLOUR: BASALT OR SIMILAR
FRONT ENTRY DOOR - TIMBER FRAME WITH GLASS PANELS
GUTTER - COLORBONDCOLOUR: BASALT OR SIMILAR
WINDOW FRAMES - ALUMINIUM -POWDERCOATEDCOLOUR: WHITE OR SIMILAR
POSTS AND FASCIA FINIALS -TIMBERCOLOUR: WHITE OR SIMILAR
GABLE CLADDING - TIMBER COLOUR: OFF WHITE HORIZONTAL CLADDING OR SIMILAR
FENCE PANELLING - LOW SPEAR COLOUR: MONUMENT OR SIMILAR
1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.
OWNER / CLIENT
DRAWINGS APPROVED
APPROVED BY: DATE SIGNATURE
DESIGNER
PROJECT MANAGER
APPROVAL TENDER CONSTRUCTION
CHECKED BY: SIGNATUREDATE
PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:
DATE:CHECKED BY:
PROJECT MGR: SCALE @ A3: DRAWING NO:
TOTAL PAGES:
REV:DRAWING TITLE:
File
Path
:Dr
awing
Plot
ted:
L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG
ABN 80 621 185 064
www.arkexpressdesign.com.au
NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464
1 : 100
11.06.2019
A
H:\T
emp J
ob F
older
- W
ork f
rom
home
\19.06
.11 R
ockh
ampto
n\112
-114
Den
ham
St, R
ockh
ampto
n City
- DA
02. rv
t11
/06/20
19 9:
10:49
AM
DR NICHOLAS MANNING
A7001
112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288
1191 (19288)SPPROPOSED HEALTHCARE SERVICES
HC
PERSPECTIVES &FINISHES SCHEDULE
12
DENHAM STREET PERSPECTIVE1
GEORGE LANE PERSPECTIVE2
REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR
CHANGESHC 31.03.2019
9 DRAFT DA ISSUE & CONSULTANTCOORDINATION
SP 12.04.2019
10 ISSUE TO LANDSCAPECONSULTANT
SP 7.05.2019
11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019
Figured dimensions take precedence over those
Copyright of all drawings and documents and of the
Verify all dimensions on site before commencingany work or shop drawings. If any doubt ask.
work executed is vested in the Principal's Consultants.
ARCHITECTSLANDSCAPEASSOCIATESALDERSON +
PROJECT NO.:
DATE:
DRAWING TITLE:
NORTH:
PROJECT:
CLIENT:
scaled.
REV. DATE
SCALE:
DWG NO.: REVISION:
DRAWN:
DETAILS INITIAL
THIS DOCUMENT DESCRIBES THE FULL INTENTOF LANDSCAPE DESIGN.ALDERSON+ ASSOCIATES TAKE NORESPONSIBILITY FOR ANY 'AS CONSTRUCTED'VARIATION FROM THEIR DRAWINGS ANDDOCUMENTS, INCLUDING HARD LANDSCAPING SETOUT AND SOFTLANDSCAPING INSTALLATION.
EMAIL: [email protected]
LISMORE: P.O. BOX 6282 SOUTH LISMORE, NSW 2480PH:040 991 5853 PH:07 4974 1184A.B.N. 72 537 115 625
GLADSTONE: OLD MANY PEAKS SCHOOLBOYNE VALLEY, QLD 4680
A 10.5.2019 ISSUE FOR APPROVALS. DB
112-114 DENHAM STREET, ROCKHAMPTON
DR. N. MANNING
MEDICAL CENTREPROPOSED
909
APRIL 2019
LANDSCAPE
A
1:100 AT A1
909-LCP01
DB
CONCEPT PLAN
21
SHAREDZONE
TURNINGBAY
PROPOSED
PROPOSED AUTOMATIC SECURITY SLIDING GATE
D E N H A M S T .
F.F.L. 9.500
GATE
GATE
A/CUNIT
R.L. 9.250
12.57312.5734.888
40.2 48
5.955 12.573 12.573
40.234
40.234
40.234
234°57'20"234°57'20"234°57'20"
323° 26 '10 "
54°57'20" 54°57'20" 54°57'20"
144°57'20"
144°57'20"
144°57'20"
2RP619288
3RP602024
1RP602024
G E O R G E L A N E
EXISTING PATH
LOW SET BLOCKRETAIL BUILDINGF.L. 9.44
EXISTING GRASSED VERGE
WM
PP
SMH
EXISTING
SMH
RELOCATEDSEWER ACCESS.
PROPOSED RELOCATION OF SEWER LINE- REFER ARCHITECTURAL DOCUMENTS.
EXISTING SEWERAGE LINE TO BE REMOVED.
EXTENSION OF BITUMEN SEALINGTO FENCE LINE AS PER ARCHITECTURALSCHEME.
EXISTING FENCING TO BE REMOVED.
EXTENT OF PROHIBITED PLANTING ZONE FOR TRAFFIC SIGHT LINES (SHOWN HATCHED).PLANTING LIMITED TO LOW HEIGHT HEDGINGAND GROUNDCOVERS.
1600mm H SANDSTONE PIERED FENCEWITH STEEL PICKET INFILL PANELS AS PERARCHITECTURAL SCHEME.
NEWPATHCONC.
RWT
RWT
EXISTING SHED TO BE DEMOLISHED.
MEDICAL CENTREPROPOSED
CAR PORT
ROOF OVER PARKING BAYS AS PERARCHITECTURAL SCHEME.
PROPOSED RELOCATEDSEWER ACCESS.
BINSTORE
F.F.L. 9.465
PATIO
ENTRY
3
UP
STAIR
RAMP(1:14GRAD.)
R.L. 9.200UP
The landscape treatment for the proposed development is directedtowards the establishment of an attractive setting for the built forms,emphasising site integration and amenity.Treatment is fully integrated with storm water requirements and based on water sensitive design principles e.g.: efficient irrigation design, maximising storm water infiltration etc.CPTED principals will be incorporated throughout the
surveillance requirements.The garden layouts are based on simple geometric forms, reflecting the built forms set within. This ensures visual unity, integration and
LANDSCAPE TREATMENT- GENERALLY
Plant arrangements are designed to maximise visual amenity
Plant layering produces simple and easily maintained visual
Planting is designed to reinforce elements of the built form and site
sense of enclosure, establishing focal points and emphasis on elements, providing amenity shade and establishing visual screening.
Plant selection is based on site suitability and longevity, with an emphasis on native plants.
PLANTING APPROACH
landscape.
Shrubs in particular, are selected for hardiness, longevity and according to their ability to retain vigour with periodic pruning to
LEGEND:GRASSED AREA
MULCHED GARDEN BED
BARK MULCH ONLY
CONCRETE PATH
EXISTING TREE / SHRUBTO BE REMOVED.
AMENITY SHADE TREE
SCREENING SHRUBS
GB
BM
SELECT COLOURED, ROCK SALT
Planting of varying heights, to the street frontage softens the built
arrival and visual appeal of the development, and provides a simple spatial definition between public and private space.
for casual surveillance in accordance with CPTED principles.
STREET BOUNDARY ALIGNMENT
form, visually integrates it with the site, enhances the sense of
Low height planting to street frontages maximises opportunities
The provision of shade trees is an integral theme of the proposed
Shade trees are located where possible, adjacent paved areasto reduce heat and glare reflected from these hard surfaces.Shade trees also reduce the amount of heat load on the building.Shade trees further aid the integration of the building by modifyingits scale and acting as a partial visual screen from the surrounding
Shade tree species are carefully selected based on their suitability
AMENITY SHADE
for incorporation around buildings and infrastructure.
The incorporation of densely planted garden beds to boundaries
properties.
SCREEN PLANTING
provides a visual screen between the development and adjoining
This planting can also significantly reduce reflected heat and glare
BM
GB GB GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
TEXTURED CONCRETE.
RR
R
R
R
R
LOW HEIGHT CLIPPED HEDGE
POTTED PLANTING
VINE PLANTINGS TO TRELLIS SCREENINGEXISTING WALL AND PROVIDINGPLEASANT OUTLOOK FROM INTERIOR OFPROPOSED CLINIC.
LOW HEIGHT SHADE TOLERANT PLANTINGSTO FOREGROUND OF TRELLIS.
RAINWATER TANK AS PER ARCHITECTURALSCHEME- MOUNT ON CONCRETE SLAB.
RAINWATER TANK AS PER ARCHITECTURALSCHEME- MOUNT ON CONCRETE SLAB.
LOW HEIGHT CLIPPED HEDGING TO FENCE LINE.HEDGE TO BE KEPT AT SUITABLE HEIGHT TOBLOCK FOREGROUND BUT MAINTAIN VISTAS TOPARK OPPOSITE.
LOW HEIGHT MASS PLANTING BETWEEN HEDGING AND PATH.
NEW PATH
1600mm H SANDSTONE PIERED FENCEWITH STEEL PICKET INFILL PANELS AS PERARCHITECTURAL SCHEME.
EXISTING GRASSED VERGE- TO BE MADE GOODWHERE DISTURBED BY WORKS.
EXISTING PATH
AMENITY SHADE TREE TYP.- EG: Brachychiton acerifolium
LOW HEIGHT CLIPPED HEDGING TO FENCE LINEPARTIALLY RETURNING ALONG GEORGE LANEFRONTAGE.
RAISED PLANTER TYP. AS PER ARCHITECTURALDETAILS.
MASS PLANTED GROUNDCOVERS UNDERLINE OF SHADE TREES.
SCREEN PLANTING TO BOUNDARY.SYZIGIUM SPECIES LIGHTLY PRUNEDTO ENCOURAGE DENSE GROWTH.
EXISTING COLORBOND FENCETO BE RETAINED.
SHADE TREE WITH VERTICAL HEIGHT TO PROVIDE PRIVACYFROM ADJACENT PREMISES(NORTH-WEST OF SITE).
EXISTING FENCE TO BE RETAINED.
PLANTING IN LARGE URNS ORPLANTER BOXES TYP.
TOTAL SITE AREAPROPOSED LANDSCAPED AREA 223.79 Sq.m
1230 Sq.m
SITE DETAILS:
from hard paved surfaces, glazed facades and roofs.
treatment.
landscape.
(attractiveness) and visual coherence.
layout e.g.: articulating entry points and circulation, creating a
maintain shape.
development with species selected being compatible with casual
interest.
ROCK SALT FINISHED COLOURED
EXAMPLE IMAGE.CONCRETE
BRACHYCHITON ACERIFOLIUM(ILLAWARRA FLAME TREE)EXAMPLE IMAGE.
LOW HEIGHT SYZIGIUM HEDGEAND GROUNDCOVERS.EXAMPLE IMAGE.
LOW HEIGHT MASS PLANTINGEXAMPLE IMAGE.
TO FACADE RECESSES.
PLANTER BOXEXAMPLE IMAGE.
(ILLAWARRA FLAME TREE)
AS PER ARCHITECTURAL SCHEME.PARKING
R
UNDERGROUND STORMWATER DETENTION TANK(13000 L) AS PER CIVIL WORKS DETAILS.BARK MULCH OVER PLASTIC SHEETING ONLYTO THIS AREA- ALL PLANTINGS CLEAR OF TANK.
OVER PLASTIC SHEETING.
ALTERNATIVE EXTERNAL 'VIEW' TREATMENT- MURAL TO EXISTING PARTY WALL BY OTHERS.(SHOWN DASHED).SECTION OF TRELLIS NOT INCLUDED TOACCOMMODATE MURAL.
(REFER ALTERNATIVE 'VIEW' TREATMENT ABOVE).