22 15/16"
30 1/8"
21 1/16"
32"CABINETWIDTH
0"
6 1/4"
11 1/8"
15 15/16"
12" 9 11/16"
12"
4 7/16"
LEFT SIDE(SERVICE ACCESS) VIEWELECTRICAL
ENCLOSURELOCATION
ALTERNATESUPPLY AIROPENING
1
34 1/16"CABINETLENGTH
FRONT SIDE(O/A INTAKE) VIEW
ALTERNATESUPPLY AIROPENING
28 1/2" 2 7/8"
12"
12" 11"
10"
TOP VIEW
AS SHIPPED SUPPLY AIR OPENING
40 1/2"OVERALL
WIDTH
24 13/16"
24 15/16"
RIGHT SIDE(NON-ACCESS) VIEW
ALTERNATESUPPLY AIROPENING
74 1/8"OVERALLHEIGHT
37 3/16"OVERALLLENGTH
3"
4 7/16"
12"
11" 12"
BACK SIDE(SERVICE ACCESS) VIEW
REMOTE CONDENSER ORWATER CONNECTIONS ANDCONDENSATE STUB LOCATION
ALTERNATESUPPLY AIROPENING
2
3' SERVICE CLEARANCE REQUIRED
NOTES:
UNIT CAN BE FIELD CONFIGURED FOR ANY ALTERNATE SUPPLY AIR LOCATION SHOW1.SEE I/O MANUAL FOR DETAILED INFORMATION TO RELOCATE SUPPLY AIR OPENINGADD AN APROXIMATE 1/2" TO CABINET DIMENSIONS FOR EXTERIOR PANEL FASTENERS2.FILTER RACK AND ALL DOORS ARE REMOVABLE FOR ADDITIONAL CLEARANCE 3.
2
1 SUPPLY LOCATION DIMENSIONS ARE TYPICAL FOR LEFT SIDE AND RIGHT SIDE VIEW
SUPPLY LOCATION DIMENSIONS ARE TYPICALFOR FRONT SIDE AND BACK SIDE VIEW
2 1
FILTERUNIT SIZE
(TONNAGE)4" FILTER
MERV RATING4" FILTER
PART NUMBERNOM
WIDTHNOM
HEIGHT QTY
4-5 11 870-136 25 29 14-5 13 870-135 25 16 2
WATER COOLED AND HEAT PUMPCONDENSER CONNECTIONS
OPTIONAL REMOTE CONDENSERCONNECTIONS
CONDENSATEDRAIN
CONNECTIONWATER LINE SIZE DIMENSIONAL COPPER REFRIGERANT LINE SIZE DIMENSIONAL COPPER PVC
INLET OUTLET DISCHARGE LIQUID RETURN OUTLET1 1/4" 1 1/4" 7/8" 5/8" 1"
TONNAGE CAB WEIGHT4 7105 735
N120 W18485 FREISTADT RDGERMANTOWN, WI 53022Tel: (262) 946-7400Fax: (262) 946-7401
Drawing Number
G807-001
Page Title
Description
QV 4-15,VERTICAL
4-5 TON VERTICAL CABINET
Tolerance UnlessOtherwise Specifed
X.X .125X.XX .060X.XXX .030Angles 1
Date ReleasedDrawn
Scale
Sheet
Rev.
12/23/2019ASV
0NTS
All Dimensions in InchesAll Angles 90
All outside corners 0.125" filletUnless Otherwise Specified
Third Angle Projection
G807-001
Part weight
Desert Aire has a policy of continuous product and quality improvement.Specifications and dimensions aresubject to change without notice.
This drawing and information contained herein are the exclusive property of the
Desert Aire Corporation. Any use detrimentalto the interests of Desert Aire is prohibited.
ALL DIMENSIONS ARE IN INCHESTOLERANCE 1/8"
1/4
27 15/16"
30 1/8"
21 1/16"
35"CABINETWIDTH
0"
9 1/4"
15 1/4"
21 3/16"
22" 6 7/16"
13"
4"
LEFT SIDE(SERVICE ACCESS) VIEW
ELECTRICALENCLOSURE
LOCATION
ALTERNATESUPPLY AIROPENING
1
46 1/16"CABINETLENGTH
FRONT SIDE(O/A INTAKE) VIEW
ALTERNATESUPPLY AIROPENING
2
13"
22"
11"
38 15/16" 3 5/16"
12"
DISCHARGE VIEW
AS SHIPPED SUPPLY AIR OPENING
43 1/2"OVERALL
WIDTH
24 13/16"
29 15/16"
RIGHT SIDE(NON-ACCESS) VIEW
1
79 1/8"OVERALLHEIGHT
49 3/16"OVERALLLENGTH
3"
22" 12"
13"
4"
BACK SIDE(SERVICE ACCESS) VIEW
REMOTE CONDENSER ORWATER CONNECTIONS ANDCONDENSATE STUB LOCATION
ALTERNATESUPPLY AIROPENING
ALTERNATESUPPLY AIROPENING
2
3' SERVICE CLEARANCE REQUIRED
NOTES:
UNIT CAN BE FIELD CONFIGURED FOR ANY ALTERNATE SUPPLY AIR LOCATION SHOW1.SEE I/O MANUAL FOR DETAILED INFORMATION TO RELOCATE SUPPLY AIR OPENINGADD AN APROXIMATE 1/2" TO CABINET DIMENSIONS FOR EXTERIOR PANEL FASTENERS2.FILTER RACK AND ALL DOORS ARE REMOVABLE FOR ADDITIONAL CLEARANCE 3.
SUPPLY LOCATION DIMENSIONS ARE TYPICAL FOR LEFT SIDE AND RIGHT SIDE VIEW
SUPPLY LOCATION DIMENSIONS ARE TYPICALFOR FRONT SIDE AND BACK SIDE VIEW
1
2
FILTERUNIT SIZE
(TONNAGE)4" FILTER
MERV RATING4" FILTER
PART NUMBERNOM
WIDTHNOM
HEIGHT QTY
8-10 11 870-106 20 25 28-10 13 870-134 20 25 2
TONNAGE CAB WEIGHT8 105010 1120
WATER COOLED AND HEAT PUMPCONDENSER CONNECTIONS
OPTIONAL REMOTE CONDENSERCONNECTIONS
CONDENSATEDRAIN
CONNECTIONWATER LINE SIZE DIMENSIONAL COPPER REFRIGERANT LINE SIZE DIMENSIONAL COPPER PVC
INLET OUTLET DISCHARGE LIQUID RETURN OUTLET1 1/4" 1 1/4" 1 1/8" 5/8" 1"
N120 W18485 FREISTADT RDGERMANTOWN, WI 53022Tel: (262) 946-7400Fax: (262) 946-7401
Drawing Number
G807-001
Page Title
Description
QV 4-15,VERTICAL
8-10 TON VERTICAL CABINET
Tolerance UnlessOtherwise Specifed
X.X .125X.XX .060X.XXX .030Angles 1
Date ReleasedDrawn
Scale
Sheet
Rev.
12/23/2019ASV
0NTS
All Dimensions in InchesAll Angles 90
All outside corners 0.125" filletUnless Otherwise Specified
Third Angle Projection
G807-001
Part weight
Desert Aire has a policy of continuous product and quality improvement.Specifications and dimensions aresubject to change without notice.
This drawing and information contained herein are the exclusive property of the
Desert Aire Corporation. Any use detrimentalto the interests of Desert Aire is prohibited.
ALL DIMENSIONS ARE IN INCHESTOLERANCE 1/8"
2/4
27 15/16"
44 3/16"
23 1/4"
35"CABINETWIDTH
0"
9 1/4"
15 1/4"
21 3/16"
LEFT SIDE(SERVICE ACCESS) VIEW
ELECTRICALENCLOSURE
LOCATION
ALTERNATESUPPLY AIROPENING
1
1
2
46 1/16"CABINETLENGTH
72 1/8"
23 1/4"
FRONT SIDE(O/A INTAKE) VIEW
4
ALTERNATESUPPLY AIROPENING
13"
24"
11"
38 15/16" 4 1/8"
11"
DISCHARGE VIEW
AS SHIPPED SUPPLY AIR OPENING
43 1/2"OVERALL
WIDTH
39 1/2"
29 7/8"
24" 5 3/8"
5"
13"
RIGHT SIDE(NON-ACCESS) VIEW
ALTERNATESUPPLY AIROPENING
95 3/8"OVERALLHEIGHT
49 3/16"OVERALLLENGTH
3"
24" 11"
5"
13"
BACK SIDE(SERVICE ACCESS) VIEW
REMOTE CONDENSER ORWATER CONNECTIONS ANDCONDENSATE STUB LOCATION
ALTERNATESUPPLY AIROPENING
SHOWN AS SHIPPED
FAN BOXSECTION
3' SERVICE CLEARANCE REQUIRED
MAIN UNITSECTION
2
NOTES:
UNIT CAN BE FIELD CONFIGURED FOR AN ALTERNATE SUPPLY AIR LOCATION SHOWN1.SEE I/O MANUAL FOR DETAILED INFORMATION TO RELOCATE SUPPLY AIR OPENINGADD AN APROXIMATE 1/2" TO CABINET DIMENSIONS FOR EXTERIOR PANEL FASTENERS2.FILTER RACK AND ALL DOORS ARE REMOVABLE FOR ADDITIONAL CLEARANCE3.QV15 UNIT IS SHIPPED IN TWO PIECES SEE I/O MANUAL FOR ASSEMBLY INSTRUCTIONS4.QV15 UNIT IS SHOWN ASSEMBLED IN ALL VIEWS UNLESS NOTED5.
QV15 FAN BOX IS SHIPPED SEPARATEAND FIELD INSTALLED
QV15 MAIN UNIT
3
4
3
SUPPLY LOCATION DIMENSIONS ARE TYPICAL FOR LEFT SIDE AND RIGHT SIDE VIEW
SUPPLY LOCATION DIMENSIONS ARE TYPICALFOR FRONT SIDE AND BACK SIDE VIEW
1
2
FILTERUNIT SIZE
(TONNAGE)4" FILTER
MERV RATING4" FILTER
PART NUMBERNOM
WIDTHNOM
HEIGHT QTY
15 11 870-107 20 20 415 13 870-129 20 20 4
WATER COOLED AND HEAT PUMPCONDENSER CONNECTIONS
OPTIONAL REMOTE CONDENSERCONNECTIONS
CONDENSATEDRAIN
CONNECTIONWATER LINE SIZE DIMENSIONAL COPPER REFRIGERANT LINE SIZE DIMENSIONAL COPPER PVC
INLET OUTLET DISCHARGE LIQUID RETURN OUTLET1 1/2" 1 1/2" 1 1/8" 7/8" 1"
TONNAGE CAB WEIGHT15 1560
N120 W18485 FREISTADT RDGERMANTOWN, WI 53022Tel: (262) 946-7400Fax: (262) 946-7401
Drawing Number
G807-001
Page Title
Description
QV 4-15,VERTICAL
15 TON VERTICAL CABINET
Tolerance UnlessOtherwise Specifed
X.X .125X.XX .060X.XXX .030Angles 1
Date ReleasedDrawn
Scale
Sheet
Rev.
12/23/2019ASV
0NTS
All Dimensions in InchesAll Angles 90
All outside corners 0.125" filletUnless Otherwise Specified
Third Angle Projection
G807-001
Part weight
Desert Aire has a policy of continuous product and quality improvement.Specifications and dimensions aresubject to change without notice.
This drawing and information contained herein are the exclusive property of the
Desert Aire Corporation. Any use detrimentalto the interests of Desert Aire is prohibited.
ALL DIMENSIONS ARE IN INCHESTOLERANCE 1/8"
3/4
DW
LEFT SIDE(SERVICE ACCESS) VIEW
1
30"
9 3/16"
DISCHARGE VIEW
1
DL
DH EH
FRONT SIDE(O/A INTAKE) VIEW
1
1
FACTORY INSTALL ON RIGHT HAND SIDE IF SPACE ALLOWS
1HEATER IS FACTORY SUPPLIED ACCESSORYFIELD INSTALLED
DUCT HEATER OPTION VIEWS DISCONNECT OPTION VIEW
NOTES:
DISCONNECT LOCATED AS SHOWN OR FACTORY SUPPLIED AND FIELD INSTALLED1.
NOTES:
DUCT HEATER MUST BE INSTALLED IN AIRFLOW1.ORIENTATION ORDEREDCONTACT FACTORY FOR NEW HEATER IF2.CHANGE TO SUPPLY ORIENTATION IS DESIRED
N120 W18485 FREISTADT RDGERMANTOWN, WI 53022Tel: (262) 946-7400Fax: (262) 946-7401
Drawing Number
G807-001
Page Title
Description
QV 4-15,VERTICAL
OPTIONS
Tolerance UnlessOtherwise Specifed
X.X .125X.XX .060X.XXX .030Angles 1
Date ReleasedDrawn
Scale
Sheet
Rev.
12/23/2019ASV
0NTS
All Dimensions in InchesAll Angles 90
All outside corners 0.125" filletUnless Otherwise Specified
Third Angle Projection
G807-001
Part weight
Desert Aire has a policy of continuous product and quality improvement.Specifications and dimensions aresubject to change without notice.
This drawing and information contained herein are the exclusive property of the
Desert Aire Corporation. Any use detrimentalto the interests of Desert Aire is prohibited.
ALL DIMENSIONS ARE IN INCHESTOLERANCE 1/8"
4/4