Permanent Strainers Temporary Strainers Line Blinds Coupon Holders Sampling Equipment Pipeline Accessories Meter Provers Metering Systems L.A.C.T. Units Mag-Tek™ Sphere Detector Switches Custom Fabrication Practical Applications - Exceptional Service Toll Free: (800) 331-3790 Oklahoma Home Office: (918) 445-1141 Fax: (918) 445-4617 www.weamco.com
Transcript
  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Mag-Tek SphereDetector Switches

    Custom Fabrication

    Practical Applications - Exceptional Service

    Toll Free: (800) 331-3790Oklahoma Home Office: (918) 445-1141

    Fax: (918) 445-4617www.weamco.com

  • Keeping customers coming to WeamcoMetric is the only way for us to stayin business and secure our future. Therefore we the employees ofWeamcoMetric make the following commitments.

    We will to the best of our ability:

    Provide our customers with top quality, defect-free, cost competitive products,

    which shall meet or exceed the requirements and specifications.

    Treat our customers with courtesy and respect by giving them individual

    assistance each and every time they contact us or come by.

    Answer each customers questions with the most honest, thoughtful and

    knowledgeable response available.

    Respond to all customer inquiries in a reasonable and timely manner.

    Provide products on schedule while maintaining high quality standards.

    COMMITMENT STATEMENT

    2350 Industrial Dr.Sapulpa, OK 74066

    P.O. Box 9555Tulsa, OK 74157-0555

    Phone: (918) 445-1141

    Toll Free: (800) 331-3790

    Fax: (918) 445-4617

    www.weamco.com

  • Products: WeamcoStrainers: Fabricated Vertical Permanent Basket Tee Y andAssorted Temporaries (Cones, Baskets, etc.)Line Blinds Spacer Rings Bleed Rings Corrosion Coupon HoldersSample CoolersCustom Fabrication & Pipeline Accessories.

    MetricBi-directional Meter Provers Uni-directional Meter Provers Volumetric Meter Provers (Tank Style) Portable ProversMetering SystemsLACT UnitsSampling SystemsSphere & Pig Detector Switches (Home of Mag-Tek)Custom Fabrication of measurement equipment.

    Authorized Codes: ASME B31.1, B31.3, B31.4 and B31.8, API Chapter 4ASME Section VIII Div. 1,Design, Fabrication & Testing

    Physical Address: 2350 Industrial Dr.Sapulpa, OK 74066

    Mailing Address: P.O. Box 9555Tulsa, OK 74157-0555

    Web Site: www.weamco.com

    Phone: (918) 445-1141

    Toll Free: (800) 331-3790

    Fax: (918) 445-4617

    Hours: Monday - Friday, 7:30AM to 4:30PM CSTClosed - Major Holidays

    Organized: Corporation, State of Oklahoma, USA 1973.

    Federal Identification Number: 73-0967826

    Duns Number: 06-455-8554

  • Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • WeamcoMetric Strainers

    For over thirty years the Weamco division of WeamcoMetric has been furnishing dependable

    top quality Permanent and Temporary Strainers of all types to industries all over the world.

    Industries such as Pipelines, Hydrocarbon, Chemical, Power, Gas, Pulp & Paper, Process Plants,

    and Refineries all over the world recognize WeamcoMetric as The First Name In Strainers. Our

    top quality products would be reason enough to come to WeamcoMetric, but much of our

    success is attributed to our dedication to seeing that every customer or potential customer is

    handled with the most exceptional service we have to offer. WeamcoMetrics excellent

    reputation in the areas of service, quality and dependability are precious attributes we are

    proud of and protect with enthusiasm.

    At WeamcoMetric all engineering, design and manufacturing of our fabricated Strainers is

    started and completed in house. This provides us with a major advantage in the areas of

    quality control and scheduling, not to mention the cost advantages. We believe in a hands-on

    approach to detail and accountability for your work.

    WeamcoMetrics vast amount of experience and expertise affords us the ability to assist our

    customers in choosing and constructing the most practical equipment for their applications.

    When youre trying to protect expensive or critical pieces of equipment such as pumps,

    compressors, valves or meters, you need design expertise and quality you can trust for good

    dependable equipment with someone who stands behind their work. WeamcoMetric has a

    reputation of being that someone.

    We offer a variety of equipment design standards to meet your various needs and welcome

    your special requirements. Our manufacturing capabilities and technical expertise include the

    abilities to work with a vast array of materials and manufacture custom equipment to your

    exact specifications. Regardless of the complexity or simplicity of your requirements,

    WeamcoMetric is a great ally to be associated with and we welcome the opportunity to work

    with you.

    The following pages offer a vast amount of information on the design and construction of

    strainers. Please feel free to contact our staff at your convenience for personal assistance.

  • A. Strainer Definition and Purpose

    Strainers are used normally for the protection of pipeline and petroleum process equipment installeddownstream of the strainer. The equipment protected by our strainers is generally more expensive thanthe total installation cost of a strainer. Also this equipment is critical to the pipeline or process operation.

    Strainers use perforated and/or wire mesh media for straining purposes. These materials are twodimensional, meaning they do not have a Depth or Dirt Holding capacity. This means that whena debris particle is caught in the straining media the opening is blocked or plugged. This results inreduced available opening for flow. Strainer sizing and selection are critical to insure your cleaningcycle time, particle size retention and pressure drop requirements are achieved.

    B. Straining Media Selection for Basket

    The following is a general guideline of media we have typically seen used in the various applicationsshown, but is in no way intended to supercede your specific requirements. This information is strictlybased on observations made from our many years of experience and WeamcoMetric makes no guarantees that it is correct and/or applicable for your specific application.

    Liquid Turbine Meters 1/8 dia. perforated support with 40 x 40 mesh liner

    Gas Turbine Meters and Regulators 1/8 dia. perforated supportwith 80 x 80 mesh liner

    P.D. Meters 1/8 dia. perforated

    Centrifugal PumpsService: Crude Oil 1/4 dia. perforatedRefined Products 1/8 dia. perforatedCoke Fines 3/4 flattened expanded metalWater 1/8 dia. to 3/8 dia. perforated

    Natural Gas Compressors Varies by manufacturer recommendations,1/8 dia. perforated to 50 microns

    C. Strainer Design and SelectionWeamcoMetric Fabricated Strainers are manufactured in several styles or types to meet various applications.Strainer type selection should be based upon your requirements. A general guideline as follows:

    Application Description or Requirement Style WeamcoMetric Type

    1. Pumps, Flow Meters, Compressors & Vertical Basket FV or FTControl Valve Protection, Low Pressure StrainersDrop, High Capacity, ease of maintenance,several optional features.

    2. Pump Suction & Gas Regulator Protection, Tee Strainers TSF or TSW relative clean product, very adaptable to TLF or TLWvarious piping arrangements. TVF or TVW

    STRAINERS

  • Application Description or Requirement Style WeamcoMetric Type

    3. Pump Suction, HVAC, various types of Y-Strainers FYW or FYFWater Service, Boiler Feedwater, and industrialpiping systems, relative clean product, blowdownrequired for basket cleaning.

    4. Temporary Service for Start-up of Piping Temporary CP, CWI,Systems and Permanent Compressor Cone and CWOPackages, permanent service in clean Basket BP, BWI,natural gas applications. Strainers BWO

    5. Low Flow & Small Pipe Size, Flat Strainers FP or F-PFTemporary Service only.

    STRAINERS

    Rev. 3/07

  • Strainer Inquiry Form

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Please complete the following information below and Fax to WEAMCO at (918) 445-4617.

    We will be happy to recommend a Strainer for your application.

    You can also visit our website at www.weamco.com.

    Name _____________________________________________

    Company __________________________________________

    Address ___________________________________________

    City/Town_________________________________________

    State______________________ Zip Code ______________

    e-mail address ____________________________________

    Telephone: (____) ______________________

    Fax (_____) ___________________________

    1. Flow Rate

    2. Product Service & Equipment Strainer is Protecting

    3. Design Pressure

    4. Design Temperature

    5. Line Size

    6. Flange Rating

    7. Strainer Housing Material

    8. Strainer Media Material for Basket

    9. Size of Particles to Remove from Stream

    10. Maximum Pressure Drop Allowed

    11. WEAMCO Type Strainer

    12. Manufacturing Design Code

    13. Paint Requirements

    14. Temporary Strainer % Open Area

    15. Any other information or Optional Accessories

    All WEAMCO strainers are fabricated on-order, and we can custom designa unit to match your dimensional and service requirement. JUST ASK!!

  • MESH* WIRE OPENING % OPENDIA. AREA

    20 x 20 .016 .0340 46.2

    30 x 30 .013 .0203 37.1

    40 x 40 .010 .0150 36.0

    60 x 60 .0075 .0092 30.5

    80 x 80 .0055 .0070 31.4

    100 x 100 .0045 .0055 30.3

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Materials DataPerforated and Wire Cloth

    Bulletin AC307

    IF YOU DONT SEE WHAT YOU ARELOOKING FOR, PLEASE CONTACT US

    PATTERN % OPEN # HOLES MATERIAL/GAUGE

    DIA CENTERS AREA PSI C.S. 304SS 316SS

    1/16 1/8 23 74 16 22 -

    1/8 3/16 40 33 14,11 14 14*

    3/16 1/4 51 18 14 16 -

    1/4 3/8 40 8 11 14,11 14,11

    3/8 9/16 40 3,7 11 11 -

    1/2 11/16 48 2,4 11 11 -

    SIZE GAUGE % OPEN MATERIALAREA

    1/2 16 Flattened 62 C.S; 304SS

    3/4 13 Flattened 72 C.S; 304SS

    MESH* WIRE OPENING % OPENDIA. AREA

    3 x 3 .080 .2533 57.6

    4 x 4 .063 .1870 56.0

    8 x 8 .035 .0900 51.8

    8 x 8 .047 .0780 38.9

    10 x 10 .035 .0650 42.3

    * Number of wires per linear inch. All meshesshown are available, 304 S.S. and 316 S.S.Many other meshes and materials are available.

    All dimensions in inches. C.S.= Carbon Steel.

    Fine mesh requiring support

    WIRE CLOTH NORMALLY STOCKEDCoarse mesh for straining or support

    EXPANDED METAL NORMALLY STOCKEDFor Straining or Fine Mesh Wire Cloth Support

    PERFORATED PATTERNS NORMALLY STOCKED

    * Also in Monel

  • Permanent StrainersTemporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Vertical Basket StrainerTYPE FV for Horizontal Pipe Run

    Bulletin FV307

    LINE COMMON DIMENSIONS BASKET SURFACE BASKET OPEN OPEN AREA LINESIZE AREA (SQ.IN.) AREA (SQ.IN.) RATIO* SIZE

    O.D. F.F. TH BC** AC** DRAIN FV FV FV

    2 42 17 16 9 7 1 44 18 524% 23 6s 20 20 11 9 1 99 40 536% 34 8s 23 24 14 10 12 207 83 650% 46 10w 26 29 17 12 12 330 132 457% 68 12w 30 35 21 14 12 509 204 408% 810 16 34 42 25 17 12 792 317 402% 1012 18 37 46 28 18 2 1034 414 366% 1214 18 37 53 33 20 2 1232 493 358% 1416 24 44 60 36 24 2 1885 754 413% 1618 24 45 65 39 26 2 2073 829 355% 1820 26 48 71 45 26 2 2512 1005 345% 2024 30 56 95 64 31 2 4310 1724 406% 2430 36 62 108 71 37 2 5938 2375 353% 30

    *Based on Standard Basket perforated 1/8 diameter holes on 3/16 centers. Open Area and Open Area Ratio also applicable to perforated patterns 1/4diameter holes on 3/8 centers and 3/8 diameter holes on 9/16 centers. Other patterns available. See Bulletin AC307.

    All dimensions are in inches. Dimensions are applicable up to 600# ANSI. Larger line sizes available. Std. Design ASME/ANSI B31.4

    TYPE FV with Slope Top BasketFor Horizontal Pipe Run

    INFORMATION REQUIRED1. Quantity2. Flow Rate3. Design pressure and temperature4. Special Size Strainer (if other than standard, advise dimensions)5. Line size and flange rating or beveled for welding6. Wire cloth size (See Bulletin AC307) - under Strainer Design7. Housing and basket material (Carbon steel is standard) - others are available8. Special features9. Product service and equipment being protected if available.

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Vertical Basket StrainerTYPE FT for Horizontal or Vertical Pipe

    Bulletin FT307

    O.D. F.F. TH BC** AC** DRAIN FT FT FT

    2 42 17 16 9 7 1 66 26 787% 23 6s 20 20 11 9 1 140 56 758% 34 8s 23 24 14 10 12 245 98 770% 46 10w 26 29 17 12 12 366 146 505% 68 12w 30 35 21 14 12 550 220 440% 810 16 34 42 25 17 12 813 325 412% 1012 18 37 46 28 18 2 1037 415 367% 1214 18 37 53 33 20 2 1247 499 362% 1416 24 44 60 36 24 2 2019 808 442% 1618 24 45 65 39 26 2 2170 868 387% 1820 26 48 71 45 26 2 2569 1028 369% 2024 30 56 95 64 31 2 4055 1522 403% 2430 36 62 108 71 37 2 5561 2224 342% 30

    LINE COMMON DIMENSIONS BASKET SURFACE BASKET OPEN OPEN AREA LINESIZE AREA (SQ.IN.) AREA (SQ.IN.) RATIO* SIZE

    *Based on Standard Basket perforated 1/8 diameter holes on 3/16 centers. Open Area and Open Area Ratio also applicable to perforated patterns1/4 diameter holes on 3/8 centers and 3/8 diameter holes on 9/16 centers. Other patterns available. See Bulletin AC307. All dimensions are in inches. Dimensions are applicable up to 600# ANSI. Larger line sizes available. Std. Design ASME/ANSI B31.4

    **Dimensions BC and AC for the Type FT Strainer are not fixed and can be located at purchasers option within the shell length or can be offset without changing the Basket Area.

    TYPE FT with Angle Basket forHorizontal or Vertical Pipe RunAvailable with offset nozzles.

  • Estimated Pressure Drop for FV & FT Strainers

    Exam

    ple:

    A 6

    lin

    e flo

    win

    g 1,

    000

    G.P

    .M. l

    iqui

    d w

    ith a

    spe

    cific

    gra

    vity

    of 0

    .6.

    To fi

    nd th

    e pr

    essu

    re d

    rop,

    ent

    er th

    e ch

    art a

    t 1,0

    00 G

    .P.M

    . and

    inte

    rsec

    t the

    line

    repr

    esen

    ting

    a 6

    FV,

    and

    FT

    stra

    iner

    . Rea

    d to

    the

    left

    for

    each

    typ

    e of

    fabr

    icat

    ed s

    trai

    ner t

    o in

    ters

    ectio

    n of

    S.G

    . = 1

    .0.

    Follo

    w d

    iago

    nal g

    uide

    line

    sdo

    wn

    to S

    .G.

    = 0

    .6.

    Rea

    d st

    raig

    ht t

    o th

    e le

    ft fo

    r th

    e co

    rrec

    ted

    pres

    sure

    drop

    . In

    the

    exam

    ple

    the

    FV s

    trai

    ner

    wou

    ld h

    ave

    a pr

    essu

    re d

    rop

    of

    0.65

    P.S.

    I., t

    he F

    T 0.

    45 P

    .S.I.

    The

    str

    aine

    r se

    lect

    ion

    wou

    ld d

    epen

    d up

    on p

    ipin

    gco

    nfig

    urat

    ion

    and

    allo

    wab

    le p

    ress

    ure

    drop

    .

    VISC

    OSI

    TYPE

    RFO

    RAT

    EDW

    ITH

    WIR

    E M

    ESH

    LIN

    ERSS

    U1/

    8 o

    r 1/

    4 D

    IA.

    40 m

    esh

    60 m

    esh

    80 m

    esh

    100

    mes

    h

    30 (

    Wat

    er)

    Use

    Cha

    rt1.

    31.

    51.

    61.

    7

    500

    1.6

    1.9

    2.1

    2.4

    2.6

    1,00

    01.

    72.

    22.

    42.

    62.

    8

    2,00

    01.

    92.

    42.

    72.

    93.

    2

    CO

    RR

    ECTI

    ON

    FAC

    TOR

    S. M

    ULT

    IPLY

    PR

    ESSU

    RE

    DRO

    P B

    Y:

    Bulletin PD307

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    WEIGHTSBASED ON CATALOG STANDARD UNITS

    FV AND FT STRAINERS

    2 150# 3 150# 4 150# 6 150# 8 150# 10 150# 12 150#68# 120# 190# 295# 460# 690# 910#

    2 300# 3 300# 4 300# 6 300# 8 300# 10 300# 12 300#95# 180# 280# 450# 670# 1020# 1350#

    2 600# 3 600# 4 600# 6 600# 8 600# 10 600# 12 600#140# 290# 500# 820# 1120# 1720# 2350#

    TEE STRAINERS

    2 150# 3 150# 4 150# 6 150# 8 150# 10 150# 12 150# 16150#W-18# W-31# W-51# W-97# W-159# W-238# W-365# W-614#F-30# F-51# F-81# F-145# F-237# F-342# F-525# F-894#

    2 300# 3 300# 4 300# 6 300# 8 300# 10 300# 12 300# 16300#W-26# W-47# W-74# W-143# W-224# W-351# W-529# W-887#F-44# F-77# F-124# F-227# F-358# F-533# F-809# F-1387#

    2 600# 3 600# 4 600# 6 600# 8 600# 10 600# 12 600# 16 600#W-36# W-67# W-122# W-247# W-387# W-639# W-822# W-1426#F-60# F-113# F-206# F-409# F-627# F-1019# F-1272# F-2206#

    Bulletin WT307

    W = Weld EndsF = Flanged Ends

  • PIPE 150# 300# 600# PIPESIZE H M L H1F H2F L HIF H2F L H1F H2F SIZE

    2 5 2 1/2 5 7 1/2 10 5 1/4 7 3/4 10 1/2 5 5/8 8 1/8 11 1/4 23 6 3/4 3 3/8 6 1/8 9 1/2 12 1/4 6 1/2 9 7/8 13 6 7/8 10 1/4 13 3/4 34 8 1/4 41/8 7 1/8 11 1/4 14 1/4 7 1/2 11 5/8 15 8 3/8 12 1/2 16 3/4 46 11 1/4 5 5/8 9 1/8 14 3/4 18 1/4 9 1/2 15 1/8 19 10 1/2 16 1/8 21 68 14 7 11 18 22 11 3/8 18 3/8 22 3/4 12 1/2 19 1/2 25 810 17 8 1/2 12 1/2 21 25 13 1/8 21 5/8 26 1/4 14 3/4 23 1/4 29 1/4 1012 20 10 14 1/2 24 1/2 29 15 1/8 25 1/8 30 1/4 16 3/8 26 3/8 32 3/4 1214 22 11 16 27 32 16 5/8 27 5/8 33 1/4 17 3/4 28 3/4 35 1/2 1416 24 12 17 29 34 17 3/4 29 3/4 35 1/2 19 1/4 31 1/4 38 1/2 1618 27 13 1/2 19 32 1/2 38 19 3/4 33 1/4 39 1/2 21 34 1/2 42 1820 30 15 20 11/16 35 11/16 41 3/8 21 3/8 36 3/8 42 3/4 22 3/4 37 3/4 45 1/2 2024 34 17 23 40 46 23 5/8 40 5/8 47 1/4 25 1/4 421/4 50 1/2 24

    Tee Strainers

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comBulletin TEE307

    Dimensions in inches and are based on standard weld tee with raised face or ring joint weld neck flanges. Standard weight tee and W.N. bore for 150# and 300# . Extra strong teeand W.N. bore for 600# , 400# , 900# , 1500# , 2500# in RF/FF/RJ and other facings available. Blind flange can be tapped for blowdown. Quick opening closures available on anytype or rating tee strainer. Advise pipe schedule or wall thickness required for higher pressure applications. Std. Design ASME/ANSI B31.4

    TYPE TSW (Weld Inlet & Outlet)TYPE TSF (Flanged Inlet & Outlet)TYPE TSFI (Flanged Inlet, Weld Outlet)TYPE TSFO (Weld Inlet, Flanged Outlet)

    TYPE TLW (Weld Inlet & Outlet)TYPE TLF (Flanged Inlet & Outlet)TYPE TLFI (Flanged Inlet, Weld Outlet)TYPE TLFO (Weld Inlet, Flanged Outlet)

    TYPE TVW (Weld Inlet & Outlet)TYPE TVF (Flanged Inlet & Outlet)TYPE TVFI (Flanged Inlet, Weld Outlet)TYPE TVFO (Weld Inlet, Flanged Outlet)

    INFORMATION REQUIRED1. Quantity2. Line Size3. Flange rating & Face4. Weamco type5. Housing material *6. Housing Pipe Schedule7. Basket material *8. Mesh liner if required9. Additional Features

    *Carbon Steel is standard. Other materials are available.

    EXAMPLE: 2 6 300# RF WEAMCO type TSF, C.S. housing,Std. Wt. 304 SS basket, 1 NPT blowdown

    Standard Basket Perforated 1/8 Diameter holes on 3/16 Centers

    (Other Patterns, wire mesh and liners available,see WEAMCO Bulletin AC 307 or Consult Factory)

  • TYPE FYW TYPE FYF BLOWDOWNSIZE O.D. W-W F-F L (NPT)

    4 4 1/2 18 1/2 26 12 3/4

    6 6 5/8 20 1/4 30 16 3/4

    8 8 5/8 26 37 20 1

    10 10 3/4 33 1/2 46 23 1

    12 12 3/4 38 1/4 51 26 1 1/2

    14 14 42 1/2 56 29 1 1/2

    16 16 47 1/2 62 32 1 1/2

    18 18 53 68 36 1 1/2

    20 20 57 1/2 73 39 2

    24 24 63 1/2 80 43 2

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Y Strainers

    Bulletin FY307

    WEAMCO Y Strainers can be fabricated from any commercially available pipe including carbon steel, low and intermediatealloy steels and stainless steel. The F-F dimensions shown for the Type FYF Strainer is applicable for any flange rating or facing150# ANSI thru 300# ANSI. Higher pressures on application. Special Dimensions available to match your piping requirements.Std. Design ASME/ANSI B31.4

    TYPE FYW(Weld End)

    INFORMATION REQUIRED1. Quantity2. Line Size3. Weamco type4. Flange Rating and Face5. Housing material *6. Housing Pipe Schedule7. Basket material *8. Mesh liner if required9. Additional Features

    *Carbon Steel is standard. Other materials are available.

    EXAMPLE: 2 6 300# RF WEAMCO type FYW, C.S. housing,Std. Wt. 304 SS basket, 1 NPT blowdown, 300# R.F.

    Standard Basket Perforated 1/8 Diameter holes on 3/16 Centers

    (Other Patterns, wire mesh and liners available,see WEAMCO Bulletin AC 307 or Consult Factory)

    Larger sizes on application Dimensions are in inches.

    TYPE FYF(Flanged End)

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Optional AccessoriesFor Permanent Strainers

    Bulletin OA307

    Threaded Quick Opening ClosureFig. 500

    Swing Bolt Quick Opening Closure(only for 150# ANSI use)

    Davit for Blind Flange

    Blowdown Basket

    Flat Top Basket Offset Nozzles

    Side Drains

    Additional Surface Area FV Basket

    Legs or Base Skirt

    Drain, vent, differential pressure etc., can be furnished threaded or flanged.

    Any manufacturers closures may be used subject to requirements and availability.

    THE ABOVE ILLUSTRATIONS COVER THE MORE POPULAR FEATURES. MANYOTHER DESIGN CONFIGURATIONS CAN BE OFFERED.

    Double Bolt QuickOpening Closure

  • WeamcoMetric offers our exclusive Differential Pressure Gauge for continuous monitoring of pressure drop in Strainers and other applications where DP is a concern . Easy to read display, keeps you informed of critical pressure differentialsso you can take the appropriate actions before any problems occur.

    This DP arrangement can be installed by WeamcoMetric with your strainer purchase or the DP Gauge can be purchased separately for your field installation onexisting strainers installed in the field.

    Contact us today for price and shipment.

    Also available with Follower Pointer (Tell Tale) option.

    Differential PressureGauge Assembly

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comBulletin OA307

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Cone Strainers

    Bulletin CP307

    TYPE CWIWire Cloth Inside

    *Perforated Support

    TYPE CP

    TYPE CWOWire Cloth Outside*Perforated Support

    TYPE CW1 Ply Heavy

    Wire

    8 X 8 STD

    TYPE CTPExpanded SupportInside and Outside

    LENGTH L CLINE STD.SIZE LGTH. 75% 100% 150% 200% 300%

    2 4 4 6 8 113 6 6 9 12 184 8 8 10 13 206 11 11 13 18 278 12 12 17 23 3410 12 12 14 22 29 4412 12 12 16 26 35 5014 14 14 18 27 36 5316 16 16 21 31 40 6018 18 18 24 35 46 6820 20 20 26 39 51 7624 23 23 31 45 60 9030 29 29 38 57 76 11436 33 33 44 66 88 126

    REFERENCE STRAINER DESIGN SELECTION ANDCONSTRUCTION SECTION FOR OPTIONAL MATERIALS.(Reference Bulletin AC307 for Wire Cloth, Perforated

    and expanded metal availability.)

    STANDARD MATERIAL ISPERFORATED 1/8 DIAMETERHOLES ON 3/16 CENTERS

    40% OPEN AREACARBON STEEL

    Percent open areas shown are compared to the cross sectional flow areaof Standard Weight Pipe. All dimensions are in inches. Standard lengthdesigned to fit weld neck flange plus long radius weld elbow. OD isdesigned to fit inside flange bolt hole circle. Full face is available, add FF totype of strainer. ID is designed to fit inside standard weight pipe for 150#and 300# rating, extra strong pipe for 600# rating. Advise pipe wall orschedule for higher pressure ratings. See Bulletins BP307 and FP307 foradditional Temporary Strainer information.

    * Expanded metal support available

    Available with any typetemporary strainer

    (Customers Choice)

    12 GA. (Min.) in Carbon Steel14 GA. (Min.) in Carbon Steel

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Cone StrainersAdditional Features

    Bulletin CP307

    CONES & BASKET STRAINERSDIMENSIONS IN INCHES

    ID OD300/400

    150/300 lb. 400/600 lb. 900/1500 lb. 150/300 lb. 400 lb. 600 lb. 900 lb. 1500 lb. 600 lb. 900 lb. 1500 lb. 2500 lb.SIZE RF/FF/RJ RF/RJ RF/RJ RF/FF RF RF RF RF RJ RJ RJ RJ

    3/4 5/8 5/8 2 1/8 2 1/2 2 1/2 2 5/8 2 5/8 R13 R14 R14 R161 7/8 7/8 2 1/2 2 3/4 2 3/4 3 3 R16 R16 R16 R18

    1 1/4 1 1/8 1 1/8 2 7/8 3 1/8 3 1/8 3 1/4 3 3/8 R18 R18 R18 R211 1/2 1 3/8 1 3/8 3 1/4 3 5/8 3 5/8 3 3/4 3 3/4 R20 R20 R20 R23

    2 1 7/8 1 7/8 4 4 1/4 4 1/8 5 1/2 5 1/2 R23 R24 R24 R262 1/2 2 1/4 1 15/16 4 5/8 5 5 6 1/4 6 3/8 R26 R27 R27 R28

    3 2 7/8 2 33/64 5 1/4 5 3/4 5 3/4 6 1/2 6 3/4 R31 R31 R35 R324 3 3/4 3 5/8 6 3/4 6 7/8 7 1/2 8 8 1/8 R37 R37 R39 R386 5 3/4 5 5/8 8 5/8 9 5/8 10 1/8 11 1/4 11 R45 R45 R46 R478 7 1/2 7 3/8 10 3/4 11 3/4 12 3/8 14 13 3/4 R49 R49 R50 R5110 9 1/2 9 1/4 13 1/8 13 7/8 15 1/2 17 17 R53 R53 R54 R5512 11 1/2 11 1/8 15 7/8 16 1/4 17 3/4 19 3/8 20 1/4 R57 R57 R58 R6014 12 7/8 17 1/2 18 3/4 19 1/8 20 1/4 R61 R62 R63 16 14 3/4 20 20 7/8 22 22 3/8 R65 R66 R67 18 16 3/4 21 3/8 23 1/8 23 7/8 24 7/8 R69 R70 R71 20 18 3/4 23 5/8 25 1/4 26 5/8 27 1/4 R73 R74 R75 24 22 3/4 28 30 30 7/8 32 3/4 R77 R78 R79

    Advise PipeSchedule orFlange Dia.

    of Bore.Strainer IDwill be 1/8(small sizes)

    to 1/2(large sizes)Less than

    Flange Bore

    *

    ASA RING JOINT GASKET NUMBER(Soft iron cadmium plated is standard)

    * Advise pipe schedule or flange dia. of bore. Strainer ID will be 1/2 less than flange bore. Larger sizes available.

    Cross bracing can be installed inboth cone and basket strainersto help prevent collapse on BP,BWO, or CWO types.

    Vibration supports can be supplied onextra long strainers to help stabilizethe strainer off of the pipe wall andprevent vibration.

    Both cone and basket strainers can beinverted to obtain a high percent ofopen area in a tight piping situation.

    HOW TO ORDER1. Quantity2. Line Size3. Mating Flange Rating4. Flange face type5. Type of Strainer Required6. Length Required7. Material of Construction8. Wire Mesh & Material if required

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Basket Strainers

    Bulletin BP307

    TYPE BP

    LENGTH L BLINE STD.SIZE C LGTH. 75% 100% 150% 200% 300%

    2 14 22 22 4 5 63 2 3 3 5 7 84 22 5 5 7 9 116 4 6 6 9 12 178 52 8 8 11 14 2110 6 10 10 11 15 19 2712 7 11 11 12 18 22 3214 10 11 11 13 18 23 3316 10 12 12 14 21 25 3818 11 14 14 17 23 28 4320 13 16 16 19 26 31 4824 15 19 19 23 32 40 5730 19 21 21 28 40 50 7136 23 26 26 38 50 60 84

    REFERENCE STRAINER DESIGN SELECTION ANDCONSTRUCTION SECTION FOR OPTIONAL MATERIALS.

    REFERENCE BULLETIN AC307 FOR WIRE CLOTH,PERFORATED AND EXPANDED METAL AVAILABILITY

    12 GA. (Min.) in Carbon Steel14 GA. (Min.) in Carbon Steel

    TYPE BWIWire Cloth Inside

    *Perforated Support

    TYPE BWOWire Cloth Outside*Perforated Support

    TYPE BW1 Ply Heavy

    Wire

    Percent open areas shown are compared to the cross sectionalflow area of Standard Weight Pipe. All dimensions are in inches.Standard length designed to fit weld neck flange plus longradius weld elbow. OD is designed to fit inside flange bolt holecircle. Full face is available, add FF to type of strainer. ID isdesigned to fit inside standard weight pipe for 150# and 300#rating, extra strong pipe for 600# rating. Advise pipe wall orschedule for higher pressure ratings. See Bulletins CP307 andFP307 for additional Temporary Strainer information.

    * Expanded metal support available

    STANDARD MATERIAL ISPERFORATED 1/8 DIAMETERHOLES ON 3/16 CENTERS

    40% OPEN AREACARBON STEEL

    Available with any typetemporary strainer

    (Customers Choice)

    8 X 8 STD

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Basket StrainersAdditional Features

    Bulletin BP307

    CONES & BASKET STRAINERSDIMENSIONS IN INCHES

    ID OD300/400

    150/300 lb. 400/600 lb. 900/1500 lb. 150/300 lb. 400 lb. 600 lb. 900 lb. 1500 lb. 600 lb. 900 lb. 1500 lb. 2500 lb.SIZE RF/FF/RJ RF/RJ RF/RJ RF/FF RF RF RF RF RJ RJ RJ RJ

    3/4 5/8 5/8 2 1/8 2 1/2 2 1/2 2 5/8 2 5/8 R13 R14 R14 R161 7/8 7/8 2 1/2 2 3/4 2 3/4 3 3 R16 R16 R16 R18

    1 1/4 1 1/8 1 1/8 2 7/8 3 1/8 3 1/8 3 1/4 3 3/8 R18 R18 R18 R211 1/2 1 3/8 1 3/8 3 1/4 3 5/8 3 5/8 3 3/4 3 3/4 R20 R20 R20 R23

    2 1 7/8 1 7/8 4 4 1/4 4 1/8 5 1/2 5 1/2 R23 R24 R24 R262 1/2 2 1/4 1 15/16 4 5/8 5 5 6 1/4 6 3/8 R26 R27 R27 R28

    3 2 7/8 2 33/64 5 1/4 5 3/4 5 3/4 6 1/2 6 3/4 R31 R31 R35 R324 3 3/4 3 5/8 6 3/4 6 7/8 7 1/2 8 8 1/8 R37 R37 R39 R386 5 3/4 5 5/8 8 5/8 9 5/8 10 1/8 11 1/4 11 R45 R45 R46 R478 7 1/2 7 3/8 10 3/4 11 3/4 12 3/8 14 13 3/4 R49 R49 R50 R5110 9 1/2 9 1/4 13 1/8 13 7/8 15 1/2 17 17 R53 R53 R54 R5512 11 1/2 11 1/8 15 7/8 16 1/4 17 3/4 19 3/8 20 1/4 R57 R57 R58 R6014 12 7/8 17 1/2 18 3/4 19 1/8 20 1/4 R61 R62 R63 16 14 3/4 20 20 7/8 22 22 3/8 R65 R66 R67 18 16 3/4 21 3/8 23 1/8 23 7/8 24 7/8 R69 R70 R71 20 18 3/4 23 5/8 25 1/4 26 5/8 27 1/4 R73 R74 R75 24 22 3/4 28 30 30 7/8 32 3/4 R77 R78 R79

    Advise PipeSchedule orFlange Dia.

    of Bore.Strainer IDwill be 1/8(small sizes)

    to 1/2(large sizes)Less than

    Flange Bore

    *

    ASA RING JOINT GASKET NUMBER(Soft iron cadmium plated is standard)

    TYPE BSW or BSPStiffeners on side and top of basket Can be

    supplied on BP, BW or BWI Strainers.

    Cross bracing can be installed inboth cone and basket strainersto help prevent collapse on BP,CP, BWO, or CWO types.

    Both cone and basket strainers can beinverted to obtain a high percent ofopen area in a tight piping situation.

    HOW TO ORDER1. Quantity2. Line Size3. Mating Flange Rating4. Flange face type5. Type of Strainer Required6. Length Required7. Material of Construction8. Wire Mesh & Material if required

    * Advise pipe schedule or flange dia. of bore. Strainer ID will be 1/2 less than flange bore. Larger sizes available.

  • TYPE FPPERFORATED WITH SOLID RING

    (3 and larger only)

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Flat Strainers

    Bulletin FP307

    TYPE F-PFALL PERFORATED

    TYPE FP AND FW FLAT STRAINERSO.D.

    125 lb. FF 250 lb. FF 400 lb. 600 lb.SIZE I.D. 150 lb. RF 300 lb. RF RF RF3/4 1 2 1/8 2 1/2 2 1/2 2 1/21 1 1/8 2 1/2 2 3/4 2 3/4 2 3/4

    1 1/4 1 3/8 2 7/8 3 1/8 3 1/8 3 1/81 1/2 1 5/8 3 1/4 3 5/8 3 5/8 3 5/8

    2 2 1/4 4 4 1/4 4 1/4 4 1/43 3 1/4 5 1/4 5 3/4 5 3/4 5 3/44 4 1/4 6 3/4 7 6 7/8 7 1/25 5 1/8 7 1/2 8 3/8 8 1/4 9 3/86 6 3/8 8 5/8 9 3/4 9 5/8 10 3/88 8 3/8 10 7/8 12 11 7/8 12 1/210 10 1/2 13 1/4 14 1/8 14 15 5/812 12 1/2 16 16 1/2 16 3/8 17 7/814 14 17 1/2 19 18 7/8 19 1/416 16 20 21 1/8 21 22 1/818 18 21 3/8 23 3/8 23 1/4 2420 20 23 5/8 25 5/8 25 3/8 26 3/424 24 28 30 3/8 30 1/8 31

    STANDARD MATERIAL ISPERFORATED 1/8 DIAMETERHOLES ON 3/16 CENTERS

    40% OPEN AREACARBON STEEL

    HOW TO ORDER1. Quantity2. Line Size3. Weamco type4. Flange Rating and Face5. Perforated material 6. Mesh liner if required

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • WeamcoMetric Provers

    In most cases, accurate measurement of your valuable liquids is a vital process of your every-

    day business. WeamcoMetric has been helping companies successfully accomplish this for

    many years. With innovative designs, detailed engineering, high quality manufacturing and on

    time deliveries, WeamcoMetric has stayed at the forefront of a demanding industry. With an

    excellent knowledge of the latest technology, coupled with a vast amount of experience, you

    can rest assured you came to the right place for your measurement needs.

    WeamcoMetric manufactures several types and configurations of Conventional Meter Provers.

    The Positive Displacement Pipe Meter Prover is by far the most widely used and most reliable

    on the market today. The Pipe Provers have a Known Traceable Volume which is compared

    to the actual meter output. These two figures are used to determine what is known as a meter

    factor. By applying the meter factor to the meter output, you correct for the meters inaccuracy,

    which results in a very precise measurement. This is a valuable resource in areas such as

    custody transfer and fiscal measurement.

    WeamcoMetric recommends highly to our customers that all Provers be manufactured with the

    highest quality materials and equipment available. This insures the end user years of reliable

    low maintenance operation that results in increased money savings while reducing labor costs

    and operator error.

    WeamcoMetric Provers are in service all over the world in a variety of applications and

    industries. These include, pipeline metering terminals, hydrocarbon and chemical processing,

    refineries and petrochemical plants, tanker and barge loading facilities and metering liquid

    fuels for power plants.

    The following pages offer more specific information and photos of our design and

    manufacturing capabilities. Please feel free to contact our staff at your convenience for

    assistance in anyway with your measurement needs.

  • VII. Calibration

    Prior to placing a prover into service, a Base Prover Volume must be determined. This is done by a water-draw calibration as outlined in API Chapter 4, as previously mentioned, and API Chapter 12, Section 2, Part 4. The calibration also verifies that all components are sealing properly and are in working condition. The calibration is completed using field measures, thermometers, and gauges that are traceable to NIST, per API Chapter 4.7.

    VIII. Summary

    Conventional displacement type pipe provers are the most commonly used and accepted method of meter proving. Care of details in design specifications, construction, and calibration are essential to the proper functioning of a complete measurement system.

    IX. Please use our Prover Data Sheet for your Inquiry or Purchase Order. This will allow us to propose a more detailed offering for your application.

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comRev. 3/07

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Design and Construction:API Manual of Petroleum Measurement Standards, Chapter 4.2 Proving Systems, ASME/ANSI B31.4, ASME/ANSI B31.3.

    Radiography:Spot or 100% in accordance with API 1104.

    Hydrotest:1.5 times design pressure with chart recording.

    Inspection Flanges:Match bored, dowel pinned and O-ring groove for metal to metal seat.

    Materials:Pipe - ASTM A-106/53-Gr B Seamless(to 24 size)

    Flanges and threaded fittings - ASTM A-105

    Weld fittings - ASTM A-234 WPB

    Studs - ASTM A-193-B7

    Nuts - ASTM A-194-2H

    Gaskets - Spiralwound, 304SS

    O-Rings - Viton

    Calibration:Water draw method, repeatability within 0.02 percent per API Chapter 4.2 and Chapter 12.2.4.

    Internal Coating:Sandblast to white metal and 5 to 7 mils air dried epoxy or baked on phenolic.

    External Coating:Sandblast to white metal and one coat zinc chromate primer.

    Standard Equipment and Trim:Four way diverter valve with viton seals and differential pressure gauge

    Detector switches - Mag-Tek M-6, SSconstruction with viton seals

    Valve actuator - Electric Class I Group D Div II or manual handwheel

    Sphere - Inflatable polyurethane, nitrile,or neoprene with accessories (pump andsizing ring)

    Quick opening closure, hinged or davit type

    Thermometers - mercury in glass with 0.20F divisions and SS thermowells

    Pressure gauges with isolation valves

    Pressure relief valve

    Vent valves

    Drain valves

    Semi-skid beam supports

    TYPICAL METER PROVERSPECIFICATIONSAND OPTIONS

    Other materials and options available.

    Rev. 3/07

  • I. Meter Prover Definition

    Liquid Flow Provers are defined as a Known Traceable Volume which is usedto verify and establish a meter factor during actual flowing and operating conditions. (Traceable to NIST)

    II. Types of Conventional Meter Provers

    A) Bidirectional Prover (pipe prover): A positive displacement type prover with flow and displacer traveling in both directions by means of a 4-way diverter valve.

    B) Unidirectional Prover (pipe prover): A positive displacement type prover with flow and displacer traveling always in one direction, by means of a transferchamber, or interchange.

    C) Volumetric Tank Prover: As the name implies, this prover is a calibrated tankor vessel with a sight gauge and scale to read a metered volume.The flow must be stopped to determine the volume.

    III. Principle of Operation of a Positive Displacement Meter Prover

    We will use bidirectional provers as the example for most items.(Please see the drawing attached)

    A) To prove a meter, flow is established though the meter then to the prover viathe prover manifold valves.

    B) Flow goes into the 4-way diverter valve and forces a sphere displacer into thepipe section, which seals against the pipe walls.

    C) The displacer passes between two detector switches. The volume betweenswitches is known as the calibrated volume. This volume is compared tothe volume indicated by the meter, to determine a meter factor.

    Meter Factor = Actual Volume (Prover)Metered Volume (Meter)

    IV. Design of Meter Provers

    A) Parameters Required for Prover Design1) Service

    a) Productsb) Pressure and temperaturec) Gravityd) Viscosity e) Maximum & Minimum Flow Rate

    CONVENTIONAL LIQUIDMETER PROVERS DESIGNAND CONSTRUCTION

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comRev. 3/07

  • 2) Meter(s) to be proveda) Minimum pulses per unit volume, or K factor

    (e.g., 1000 pulses per BBL).

    3) Design Specifications and Codesa) ASME/ANSI B31.4 Pipeline (mechanical design)b) ASME/ANSI B31.3 Refinery (mechanical design)c) Material Specificationsd) Electrical Classificatione) ANSI Pressure Ratingf) Space Limitationsg) Automationh) Prover configuration, (e.g., aboveground, portable, etc.)

    API Chapter 4 Proving Systems, Section 2 Conventional Displacement Type Pipe Provers, is the industry standard for prover design, calibration, and recommended practices.

    B) Sizing and Volume Requirements

    1) Prover sizing is determined by Maximum and Minimum Sphere Velocities

    Maximum: Unidirectional - 10 ft/sec.Bidirectional - 5 ft/sec. or higher. (see API 4.2)

    Minimum: depends on lubricating properties of the product --low velocities may cause sphere to jerk or surge

    Recommend 1.0 ft/sec. min.

    See API Chapter 4, Paragraph 4.3.4

    2) Prover volume is determined by: a) API specifies the accumulation of 10,000 unaltered meter pulses

    between detector switches. (see e. below)b) Meter K Factor (or pulses per unit volume).c) Repeatability of the detector switches and system. d) Prover counter resolutione) Use of Double Chromometry to allow use of Reduced Volume Provers

    A prover must be capable of repeating the volume between detector switches by 0.02 percent. (By Water-Draw Calibration)

    Prover sizing and Volume must be considered with other factors to have a Realistic Prover Design, e.g.:

    Space AvailableCostsMeter Selection and Pulses TransmittedProduct serviceEtc.

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comRev. 3/07

  • C) Pre-Run Length

    A prover must have a sufficient pre-run length from the launch chamber to the firstdetector switch to allow the 4-way diverter valve to cycle completely and sealproperly before the displacer triggers the first detector switch. Also allowing thedisplacer to reach uniform velocity.

    V. Prover Construction and Components

    A) Pipe: Pipe should be free of defects, dents, scratches or rust pits. Pipe should be hand-picked for uniformity and roundness.

    B) Flange Seats: Flanges in the calibrated section are match-bored, machined with O-Ring grooves for sealing, and dowel-pinned.

    C) Launch Chambers: The pipe section prior to the pre-run and calibrated section is used to launch and receive the sphere. Launch chambers should betwo pipe sizes larger to allow flow by-pass around the sphere and allow thesphere to decelerate. Also allowing easy sphere removal with the use of quickopening closures. Launch chambers can be horizontal, vertical, or inclined.

    D) Sphere and Accessories: Inflatable sphere displacers are the most common used. The sphere is normally inflated from 2% to 4% larger than the prover pipe inside diameter. The sphere is filled with 50/50 mix of glycol and water. Proper inflation and roundness are vital for sealing and repeatability.

    Sphere Materials Available: 1) Neoprene2) Nitile3) Urethane (most commonly used and can be purchased in

    various durometers)Sphere Removal ToolsPumps & Inflating KitsSizing Rings

    E) Detector Switches: Detector Switches are used to gate the pulse counter.Detector switch repeatability is crucial in determining the prover volumeand in turn proving a meter.

    The most common switch is a Mechanical Actuated Electrical type, such as our Mag-Tek M-6, which has a plunger inserted into the pipe. The sphere passesunder the plunger to raise and make the switch or contact. These switches are all pressure balanced so pressure forces are not a factor.

    Rev. 3/07

  • F) Diverter Valve: Bidirectional provers utilize a 4-way diverter valve. This valve is ported to allow flow to enter one launch chamber and exit the opposite, and by cycling the valve the flow direction is reversed. All 4-way valves are designed for speed and seat seal integrity. Valves should be equipped with a means of checking the seal for leakage (e.g., Block and Bleed Port, DP Gauge or Switch).

    G) Diverter Valve Operator: Most diverter valves are equipped with actuatorsto automate the prover operation. These can be electrical, hydraulic, or pneumatic. Electric operators are the most commonly used. Manualhandwheels, with latching mechanisms, are used on smaller systems.

    H) Internal Coatings: Internal coatings are applied to the prover for two main purposes:

    1) Protect the pipe from corrosion and pitting which can cause repeatability problems.

    2) Provide a smooth uniform surface for the sphere to travel in, and ensure a good seal with stable movement without surges or jerks.

    Common Types of Coating: 1) Air-Dried Epoxy2) Baked-On Phenolic3) None Bare (crude service)

    VI. Prover Accessories and Trim:

    1) External Paint and Insulation2) Drain Valves, Block & Bleed Type or Arrangement3) Pressure Gauges4) Thermometers5) Pressure Relief Valve6) Pressure and Temperature Transmitters7) Field Calibration Connections8) Sphere by-pass for Vertical Launch Chambers9) Skid Mounted10) Vent Valves

    WeamcoMetric always specifies and uses good quality Accessories and Trim equipment.

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.comRev. 3/07

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MECHANICAL DISPLACEMENTMETER PROVER DATA SHEET

    BULLETIN PDS 303

  • Bi-Directional ProversTypical Prover Specifications

    Bulletin BDP307

    Design and Construction:API Manual of Petroleum Measurement Standards, Chapter 4.2 Proving Systems, ASME/ANSI B31.4, ASME/ANSI B31.3.

    Radiography:Spot or 100% in accordance with API 1104.

    Hydrotest:1.5 times design pressure with chart recording.

    Inspection Flanges:Match bored, dowel pinned and O-ring groove for metal to metal seat.

    Materials:Pipe - ASTM A-106/53-Gr B Seamless(to 24 size)

    Flanges and threaded fittings - ASTM A-105

    Weld fittings - ASTM A-234 WPB

    Studs - ASTM A-193-B7

    Nuts - ASTM A-194-2H

    Gaskets - Spiralwound, 304SS

    O-Rings - Viton

    Calibration:Water draw method, repeatability within 0.02 percent per API Chapter 4.2 and Chapter 12.2.4.

    Internal Coating:Sandblast to white metal and 5 to 7 milsair dried epoxy or baked on phenolic.

    External Coating:Sandblast to white metal and one coat zinc chromate primer.

    Standard Equipment and Trim:Four way diverter valve with viton seals and differential pressure gauge

    Detector switches - Mag-Tek M-6, SSconstruction with viton seals

    Valve actuator - Electric Class I Group D Div II or manual handwheel

    Sphere - Inflatable polyurethane, nitrile,or neoprene with accessories (pump andsizing ring)

    Quick opening closure, hinged or davit type

    Thermometers - mercury in glass with 0.20F divisions and SS thermowells

    Pressure gauges with isolation valves

    Pressure relief valve

    Vent valves

    Drain valves

    Semi-skid beam supports

    All materials and equipment selected forWeamcoMetric provers are of the highest qualityand consistency. Selection is based on provenindustry standards. We accept no substitute.

    Other materials and options available.

    P.O. Box 9555 Tulsa, OK 74157-0555

    Phone: (918) 445-1141 Toll Free: (800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Bi-DirectionalMeter ProversMetering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • Bi-Directional Provers

    By far the most commonly used Prover in the industry for many years. The Bi-DirectionalDisplacement Type Pipe Prover has proven itself over and over again as one of the most reliable

    means available to verify meter readings and establish meter factors. It is still the most recom-

    mended and used Prover design in the world today.

    By definition the Bi-Directional Pipe Prover is a positive displacement type prover with flow and

    displacer traveling in both directions by means of a 4-way diverter valve. The Bi-Directional Prover

    is constructed of pipe, which can be configured in many ways. Probably the most influential

    advantage of the Pipe Prover is its ability to allow the full flow of the stream through the meter

    being proved to pass through the prover. In this regard the Bi-Directional Pipe Prover offers a

    history of long-term reliability with minimum maintenance.

  • WeamcoMetric established itself many years ago as one of the leaders in Bi-Directional Pipe

    Prover design, engineering and manufacturing. With WeamcoMetric you will be working with one

    of the most professional staffs and highly skilled manufacturing forces in the business. This

    assures that your projects will run smoothly and on schedule. Our people will do everything

    within their power to accommodate the needs and desires of our customers.

    (For more information concerning this and other types of Provers, please see our Conventional

    Liquid Meter Prover Design and Construction Section in this catalog.)

  • Uni-Flow ProversTypical Prover Specifications

    Bulletin UFP307

    Design and Construction:API Manual of Petroleum Measurement Standards, Chapter 4.2 Proving Systems, ASME/ANSI B31.4, ASME/ANSI B31.3.

    NEC Class:Class I, Div. 1, 220/440 Volt/3 phase 50 or 60 cycle.

    Radiography:Spot or 100% in accordance with API 1104.

    Hydrotest:1.5 times design pressure with chart recording.

    Inspection Flanges:Match bored, dowel pinned and O-ring groove for metal to metal seat.

    Seal Plug:Buna-N - Molded

    Materials:Pipe - ASTM A-106/53-Gr B Seamless(to 24 size)

    Flanges and threaded fittings - ASTM A-105

    Weld fittings - ASTM A-234 WPB

    Studs - ASTM A-193-B7

    Nuts - ASTM A-194-2H

    Gaskets - Spiralwound, 304SS

    O-Rings - Viton

    Calibration:Water draw method, repeatability within 0.02 percent per API Chapter 4.2 and Chapter 12.2.4.

    Internal Coating:Sandblast to white metal and 5 to 7 milsair dried epoxy or baked on phenolic.

    External Coating:Sandblast to white metal and one coat zinc chromate primer.

    Standard Equipment and Trim:Uni-Flo Interchange with PLC controls and hydraulic power unit

    Detector switches - Mag-Tek M-6D, SSconstruction with viton seals

    Sphere - Inflatable polyurethane, nitrile,or neoprene with accessories (pump andsizing ring)

    Quick opening closure, hinged or davit type

    Thermometer - mercury in glass with 0.20F divisions and SS thermowell

    Pressure gauge with isolation valve

    Pressure relief valve

    Vent valve

    Drain valve

    Skid mounted

    All materials and equipment selected forWeamcoMetric provers are of the highest qualityand consistency. Selection is based on provenindustry standards. We accept no substitute.

    Other materials and options available.

    P.O. Box 9555 Tulsa, OK 74157-0555

    Phone: (918) 445-1141 Toll Free: (800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Uni-DirectionalMeter ProversMetering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • Uni-Flo Provers

    The UNI-FLO Reduced Volume Prover has beendeveloped for use with pulse-interpolationcounters to increase resolution betweenswitches. API Chapter 4, section 2 include com-plete discussions of these designs. The UNI-FLOReduced Volume Prover is designed to exploitboth pulse-interpolation and minimum pipeprover volumes based upon switch and spheregeometry. The UNI-FLO Reduced Volume Proveris the best combination of conventional proverdesign matched to todays advanced doublechronometry flow computers.

    WeamcoMetric is a leader in the liquid measurement industry, upholding the standards ofquality design and fabrication which are essential for the equipment used by measurementspecialists. Because of the demand in the industry, WeamcoMetric has developed animproved interchange mechanism for our unidirectional prover.

    RATINGS AND SIZEModel Prover Prover Normal Overall

    Number BBL Dia Vol. Flow Range Dims (approx.)

    UFM-8 8 100 gallons Min. 200 BPH 5 wideMax. 2000 BPH 25 long, 9 high

    UFM-10 10 160 gallons Min. 350 BPH 6 wideMax. 3500 BPH 30 long, 10 high

    UFM-12 12 200 gallons Min. 500 BPH 6 wideMax. 5000 BPH 35 long, 12 high

    DESIGNED FOR: compact installation

    lighter weight

    speed of operation

    ease of water-draw calibration

  • DESIGN FEATURES:

    The most compact design on the market.

    One-button PLC controls.

    Adjustable self-induced differentialpressure switch for seal indication.

    Oversized sealing section.

    Quick-opening closure for sphereloading and retrieval.

    Rugged hydraulic power unit withpressure compensating pump anddirectional control valves.

    PROVING CYCLE & CONTROL SEQUENCE:

    A) Power On - Prover is automatically set to the ready position.

    B) Start Button - Seal Cylinder is activated and seal is determinedby the self-induced Differential Pressure Switch, launch valve isopened and sphere enters prover barrel.

    C) Proving light shows sphere in-flight.

    D) Cycle completes after last detector switch is made, prover isset to ready position again.

    THE SYSTEM IS TOTALLY INTERLOCKED!

    Seal must be indicated before launching sphere

    Launch Valve must be closed before seal is retracted.

    Theres no guessing with the UNI-FLO PLCinterchange control, its one-button operationassures correct meter proving operation.

  • Typical Prover SpecificationsVOLUMETRIC PROVERS

    Design and Construction:API Manual of Petroleum Measurement Standards, Chapter 4.2 Proving Systems, Section 4, NIST Handbook 105-3

    Hydrotest:Static water pressure

    Materials:Pipe - ASTM A-106/53-Gr B Seamless(to 24 size)

    Plate: ASTM A-36

    Flanges and threaded fittings - ASTM A-105

    Weld fittings - ASTM A-234 WPB

    Heads: ASTM A-516-Gr-70

    Studs - ASTM A-193-B7

    Nuts - ASTM A-194-2H

    Gaskets - Spiralwound, 304SS

    O-Rings - Viton

    Trim:Scales; brass, graduations engraved per specification, filled with black lines for high visibility.

    Gauge glass sets; Penderty N5A withprotection rods, 5/8 diameter glass.

    Thermometer; mercury in glass with 0.20F divisions and SS thermowell.

    PROVER RE-WORKAND REFURBISHMENT

    Typical items we can offer:Disassembly and inspection to evaluate extent of work to be performed prior to work commencement.

    Sandblast out old coating to white metal and 5 to 7 mils air dried epoxy or baked on phenolic.

    Re-work 4-way valve with soft goods kits, slips, re-chrome body and plug if required.

    New electric actuators.

    Lengthen pre-run to increase flow rate.

    Lengthen calibrated section formeter changes.

    Internal grinding or repairs of prover pipe.

    All new seats and o-rings.

    New sphere stops or ramps.

    New Mag-Tek switches.

    New sphere; inflatable polyurethane, nitrile, or neoprene with accessories (pump and sizing ring).

    External sandblasting and painting.

    Re-calibration; water draw method, repeatability within 0.02 percent per API Chapter 4.2 and Chapter 12.2.4.

    All materials and equipment selected forWeamcoMetric provers are of the highest qualityand consistency. Selection is based on provenindustry standards. We accept no substitute.

    P.O. Box 9555 Tulsa, OK 74157-0555

    Phone: (918) 445-1141 Toll Free: (800) 331-3790

    Fax: (918) 445-4617 www.weamco.comBulletin PVP307

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Portable and VolumetricMeter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Portable & Volumetric Provers

    Portable & Volumetric Pipe Provers

    WeamcoMetric established itself many years ago asone of the leaders in Portable Pipe & Volumetric MeterProver design, engineering and manufacturing. Bi-Directional Pipe Provers have always been the Proverof choice in most portable Prover applications. Itsexceptional track record in the areas of reliability andmaintenance, while remaining one of the least expen-sive, makes it a natural choice for portable Proverapplications. WeamcoMetric has manufacturedportable Provers for companies and applicationsthrough out the world. Whether you want it trailer,truck or yard wagon mounted, WeamcoMetric has theexperience and expertise to manufacture high qualityuser-friendly portable Prover designs.

    Although Volumetric Meter Provers are specialty usedprovers for the loading rack market, WeamcoMetrics past experience encompasses a vastarray of styles and designs of this type of Prover. If you have an application that would bestbe suited with a Volumetric Prover you will not find a better source for your needs.

    With WeamcoMetric you will be working with one of the most professional staffs and highlyskilled manufacturing forces in the business. This assures that your projects will run smoothlyand on schedule. Our people will do everything within their power to accommodate the needsand desires of our customers.

    (For more information concerning this and other types ofProvers, please see our Conventional Liquid Meter ProverDesign and Construction Section in this catalog.)

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Prover Refurbishment

    In todays business world the economics of what we do and how we do it, are beingscrutinized more than ever before. At no other time has it been more important to controlour spending than the present. Experience and common sense tells us that being frugal withour assets makes the all-important bottom line look much better. At WeamcoMetric we areno different and we recognize the importance of saving our customers money. One of themany areas we are continually able to do this, is in our Prover Refurbishment services. Foryears WeamcoMetric has been a leader in the ability to take used Pipe Meter Provers andrefurbish them to like-new condition at a fraction of the cost of a new Prover. In many caseswith updated technology the refurbished Prover is better than the original. Whether it isBi-Directional, Uni-Directional, Volumetric, Portable or stationary, WeamcoMetric canrefurbish your Prover. Refurbishment can be done to your desired specifications, or wewould gladly review your current service requirements along with your existing Prover andmake a recommendation on what we feel would best meet your needs, while stayingwithin your budget. Whatever your situation, you can rest assured that with WeamcoMetricsextensive experience in manufacturing and rebuilding Pipe Meter Provers, we have asolution for you. We look forward to working with you.

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Prover AccessoriesSphere Pumps & Sizing Rings

    Bulletin PA307

    Type SP-101 Sphere Pump

    n Quick disconnect tool and hosen All steel construction including resevoirn Precision machined pump cylindern Easy to use

    n Custom made to your exact requirements

    n 24 hour shipment n Precision laser cut from 1/4 Micarta

    (Advise pipe size, schedule and percent oversize required)

    Sizing Rings

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Prover AccessoriesSphere and Pig Handling Equipment

    Bulletin PA307

    Sphere Removal Toolsn Model LSHn Type SRT-M 12 through 18n Type SRT-L 20 and largern Durable, heavy metal constructionn Replaceable suction cups

    Lightweight Sphere HandlerModel LSH

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-5 Sphere Detector Switch

    Bulletin M5 307

    Pressure balanced, piston actuated proximity switch requiring no dynamic seals.

    Precision machined and factory sealed with only one movingpart, requiring no adjustment in the field. The proximity switchis set inline in a fixed position.This results in less maintenance,therefore avoiding expensive downtime and unscheduledrecalibrations. The results are years of trustworthy maintenance-free service.

    Dimensional and Switch Contact Certification available to Shell Test Stand Benchmark

    Directly interchangeable with all earlier model Metric switches.

    Adapters available to fit most any mounting configuration.

    Available in SPDT or DPDT contacts.

    Available to meet NACE or Low-Temp services.

    Designs available for above or below ground installation.

    Class I, Division 1,Groups C and D

    Hazardous Locations.Patent No.

    US 6,789,407 B1

    MAG-TEK PROVES ITWith Thousands in Service!

    There is a reason why year after year people haveplaced their trust in the MAG-TEK switch for reliable

    accurate repeatability during meter prover runs.

    IT WORKS!

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-5 Sphere Detector Switch Specifications

    Bulletin M5 307

    ADAPTERS TO FIT MOST MOUNTING CONFIGURATIONS

    HOW TO ORDER:1. Quantity2. Pipe Size3. Wall Thickness4. Contact SPDT

    or DPDT

    Switch ElementCONTACT: Environmentally Sealed

    RATING: 2 Amps @ 240 V.A.C.

    50 Milliamps @ 24 V.D.C.

    RESPONSE TIME: 0.008 Seconds

    TEMPERATURE: -40 F to +221 F

    PRESSURE RATING: 2220 PSIG

    REPEATABILITY: 0.002(Under identical operating conditions)

    Switch EnclosureWELD-ON BASE PLATE: Carbon Steel

    SPRING: 302 Stainless

    PISTON: 416 Stainless

    BODY: 303 Stainless

    O-RING: Viton

    CONDUIT OPENING: 1/2 N.P.T.

    SWITCH TERMINATION: Labeled Leads

    PECO/SMITHMALONEY

    Also Available - Halmor, Older Smith & Custom Adapters

    For Adaptors:Please contact ouroffice for the properdimensions to verifyyour application.

    MODERN MAINTENANCEMECHANICAL

    KIDD METERENGINEERS

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-5T Sphere Detector Switch ForNon-Lubricated and/or Dirty Service

    Bulletin M5T 307

    WeamcoMetric now offers a Mag-Tek ProverSphere Detector Switch designed specifically forproduct service with non-lubricating propertiesand dirty services containing abrasives such asrust and other foreign particles.

    The M-5T has a unique pressure-balanced pistondesign that has a washing action to keep foreignparticles away from the switch area.

    With technology derived from the World Renowned MAG-TEK Model M-5detector switch, you can expect years of reliable maintenance free service.

    The Model M-5T is designed with two Teflon O-Rings located in the housing. These actas guides for the piston while preventing foreign particles such as rust to gall the pistonsurface during actuation. The piston has center drilled pressure equalization ports whichstabilize operation and create a washing action throughout the switch area thus keepingforeign particles flushed out. This unique flow/suction action keeps the piston-to-switcharea clean which is a valuable asset in non-lubricated and dirty service applications.

    Class I, Division 1,Groups C and D

    Hazardous Locations.Patent No.

    US 6,789,407 B1

  • PECO/SMITHMALONEY

    MODERN MAINTENANCEMECHANICAL

    KIDD METERENGINEERS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-5T Sphere Detector Switch Specifications

    Bulletin M5T 307

    ADAPTERS TO FIT MOST MOUNTING CONFIGURATIONS

    HOW TO ORDER:1. Quantity2. Pipe Size3. Wall Thickness4. Contact S.P.D.T.

    or D.P.D.T.

    Switch ElementCONTACT: Environmentally Sealed

    RATING: 2 Amps @ 240 V.A.C.

    50 Milliamps @ 24 V.D.C.

    RESPONSE TIME: 0.008 Seconds

    TEMPERATURE: -40 F to +221 F

    PRESSURE RATING: 2220 PSIG

    REPEATABILITY: 0.002(Under identical operating conditions)

    Switch EnclosureWELD-ON BASE PLATE: Carbon Steel

    SPRING: 302 Stainless

    PISTON: 416 Stainless

    BODY: 303 Stainless

    O-RING: Viton

    CONDUIT OPENING: 1/2 N.P.T.

    SWITCH TERMINATION: Labeled Leads

    Also Available - Halmor, Older Smith & Custom Adapters

    For Adaptors:Please contact ouroffice for the properdimension sheet toverify your application.

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-6 Sphere Detector Switch

    Bulletin M6 307

    Pressure balanced, piston actuated proximity switch requiring no dynamic seals.

    Precision machined and factory sealed with only one movingpart, requiring no adjustment in the field. The proximity switchis set inline in a fixed position.This results in less maintenance,therefore avoiding expensive downtime and unscheduledrecalibrations. The results are years of trustworthy maintenance-free service.

    Directly interchangeable with all earlier model Metric switches.

    Adapters available to fit most any mounting configuration.

    Available in SPDT or DPDT contacts.

    Available to meet NACE or Low-Temp services.

    Designs available for above or below ground installation.

    Certification available to Shell Test Stand Benchmark

    Class I, Division 1,Groups C and D

    Hazardous Locations.Patent No.

    US 6,789407 B1

    MAG-TEK PROVES ITWith Thousands in Service!

    There is a reason why year after year people haveplaced their trust in the MAG-TEK switch for reliable

    accurate repeatability during meter prover runs.

    IT WORKS!

    Our Reliable patentedMag-Tek featuring anew round flanged

    weld-on base mounting.

  • PECO/SMITHMALONEY

    MODERN MAINTENANCEMECHANICAL

    KIDD METERENGINEERS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-6 Sphere Detector Switch Specifications

    Bulletin M6 307

    ADAPTERS TO FIT MOST MOUNTING CONFIGURATIONS

    HOW TO ORDER:1. Quantity2. Pipe Size3. Wall Thickness4. Contact SPDT

    or DPDT

    Switch ElementCONTACT: Environmentally Sealed

    RATING: 2 Amps @ 240 V.A.C.

    50 Milliamps @ 24 V.D.C.

    RESPONSE TIME: 0.008 Seconds

    TEMPERATURE: -40 F to +221 F

    PRESSURE RATING: 2220 PSIG

    REPEATABILITY: 0.002(Under identical operating conditions)

    Switch EnclosureWELD-ON BASE PLATE: Carbon Steel

    SPRING: 302 Stainless

    PISTON: 416 Stainless

    BODY: 303 Stainless

    O-RING: Viton

    CONDUIT OPENING: 1/2 N.P.T.

    SWITCH TERMINATION: Labeled Leads

    Also Available - Halmor, Older Smith & Custom Adapters

    For Adaptors:Please contact ouroffice for the properdimensions sheet toverify your application.

  • (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-6T Sphere Detector Switch ForNon-Lubricated and/or Dirty Service

    Bulletin M6T307

    With technology derived from the World Renowned MAG-TEK Model M-5detector switch, you can expect years of reliable maintenance free service.

    The M-6T has a unique pressure-balanced pistondesign that has a washing action to keep foreignparticles away from the switch area.

    The Model M-6T is designed with two Teflon O-Rings located in the housing. These actas guides for the piston while preventing foreign particles such as rust to gall the pistonsurface during actuation. The piston has center drilled pressure equalization ports whichstabilize operation and create a washing action throughout the switch area thus keepingforeign particles flushed out. This unique flow/suction action keeps the piston-to-switcharea clean which is a valuable asset in non-lubricated and dirty service applications.

    WeamcoMetric now offers a Mag-Tek ProverSphere Detector Switch designed specifically forproduct service with non-lubricating propertiesand dirty services containing abrasives such asrust and other foreign particles.

    Class I, Division 1,Groups C and D

    Hazardous Locations.Patent No.

    US 6,789407 B1

  • PECO/SMITHMALONEY

    MODERN MAINTENANCEMECHANICAL

    KIDD METERENGINEERS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEKModel M-6T Sphere Detector Switch Specifications

    Bulletin M6T307

    ADAPTERS TO FIT MOST MOUNTING CONFIGURATIONS

    HOW TO ORDER:1. Quantity2. Pipe Size3. Wall Thickness4. Contact SPDT

    or DPDT

    Switch ElementCONTACT: Environmentally Sealed

    RATING: 2 Amps @ 240 V.A.C.

    50 Milliamps @ 24 V.D.C.

    RESPONSE TIME: 0.008 Seconds

    TEMPERATURE: -40 F to +221 F

    PRESSURE RATING: 2220 PSIG

    REPEATABILITY: 0.002(Under identical operating conditions)

    Switch EnclosureWELD-ON BASE PLATE: Carbon Steel

    SPRING: 302 Stainless

    PISTON: 416 Stainless

    BODY: 303 Stainless

    O-RING: Viton

    CONDUIT OPENING: 1/2 N.P.T.

    SWITCH TERMINATION: Labeled Leads

    Also Available - Halmor, Older Smith & Custom Adapters

    For Adaptors:Please contact ouroffice for the properdimensions sheet toverify your application.

  • CUSTOMER _____________________________ P.O. NUMBER _______________

    TEST STAND S/N _______________________ WEAMCO/METRIC JOB ____________

    LOCATION INSTALLED _________________________________________________

    A. ________ Micrometer reading in inches at point of physical contact of micrometer anvilto Mag-Tek benchmark piston tip.

    B. ________ Test Stand Standard.

    C. ________ Micrometer reading in inches at instant of switch contact closure.

    D. ________ Face of switch flange to tip of benchmark piston at instant of switchcontact closure. (B - C) = D

    The above measurements taken with shell test stand benchmark piston.

    SWITCH DESCRIPTION:

    1) Type of Base

    2) Piston Overall Length

    3) Piston Shank Length

    4) Potted Conduit Length

    TESTED BY ___________________________ DATE ___________________

    CHECKED BY ___________________________ DATE ___________________

    CERTIFICATION SHEET FORMAG-TEK SPDT

    SWITCH S/N _________

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

  • CUSTOMER _____________________________ P.O. NUMBER _______________

    TEST STAND S/N _______________________ WEAMCO/METRIC JOB ____________

    LOCATION INSTALLED _________________________________________________

    The below measurements taken with shell test stand benchmark piston.

    SOLID LEAD:

    A. ________ Micrometer reading in inches at point of physical contact of micrometer anvilto Mag-Tek benchmark piston tip.

    B. ________ Test Stand Standard.

    C. ________ Micrometer reading in inches at instant of switch contact closure.

    D. ________ Face of switch flange to tip of benchmark piston at instant of switchcontact closure. (B - C) = D

    STRIPPED LEADS:

    A. ________ Micrometer reading in inches at point of physical contact of micrometer anvilto Mag-Tek benchmark piston tip.

    B. _________ Test Stand Standard.

    C. ________ Micrometer reading in inches at instant of switch contact closure.

    D. ________ Face of switch flange to tip of benchmark piston at instant of switchcontact closure. (B - C) = D

    SWITCH DESCRIPTION:Type of Base Piston Overall Length

    Piston Shank Length Potted Conduit Length

    TESTED BY ___________________________ DATE ___________________

    CHECKED BY ___________________________ DATE ___________________

    CERTIFICATION SHEET FORMAG-TEK DPDT

    SWITCH S/N _________

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-5 MODEL M-5DMODEL M-5T MODEL M-5TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEK MODEL M-5

    Patent No.US 6,789407 B1

    Rev. 3/07

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-5 MODEL M-5DMODEL M-5T MODEL M-5TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    General Information

    Mag-Tek features a pressure balanced, piston actuated, proximity

    switch with no dynamic seals. The switch is factory sealed, with

    no field adjustment, eliminating the chance of slipping from the

    original setting. The hemispherical shape of the piston allows

    either uni-directional or bi-directional operation. The detector

    switch is manufactured from stainless steel and designed for

    either above ground or below ground applications. Once

    installed the Mag-Tek has only one moving part, the pressure-

    balanced piston, thus allowing continuous, maintenance free,

    and accurate operation. Mag-Tek switches are also interchange-

    able with most other brands of switch mountings.

    Installation Instructions

    The standard Mag-Tek detector switch is designed for installation

    on pipe having a nominal wall thickness of 0.375 inches or less.

    If the Mag-Tek is to be used on pipe having a wall thickness

    greater than 0.375 inches, be sure to specify when ordering.

    1. Select the desired location on the pipe for the Mag-Tek

    detector switches. These points are usually, but not

    necessarily, on top of the pipe.

    2. Drill a 7/8 diameter hole at each point. Care should be

    taken to keep the drill bit centered and perpendicular to

    the pipe.

    3. All drill cuttings should be removed from inside the pipe.

    If, due to design, this cannot readily be done with a cloth

    or a stream of air, it can usually be done with a small

    mechanics extension type, hand-held magnet inserted

    through the 7/8 drilled hole.

    4. The inside of the drilled hole should be rounded or

    chamfered with a file or stone to remove sharp edges.

    5. Center the base plate guide-lip in the 7/8 diameter hole

    in the pipe, taking care to orient the base plate properly so

    that it is level and square with the pipe.

    6. With the base plate level and square, lightly tack weld

    onto the pipe. Check to be sure the base plate guide lip is

    still seated. If so, complete the seal welding with the

    required passes. Do not allow weld splatter or arc on the

    switch mounting face of the base plate. If Mag-Tek

    detector switches are to be installed on a prover after it

    has been internally coated, care should be taken to

    minimize the weld heat. It is suggested the weld be

    cooled from time to time with wet rags or other means.

    Filling the prover barrel with water, if practical, prior to

    welding, will further minimize damage to the internal coating.

    7. Check mounting face to make sure it is free from burrs and

    weld splatter. DO NOT PAINT the face of the mounting plate.

    8. Mount switch on base with (4) 3/8 cap screws.

    Recommended torque 240 inch pounds. Maximum torque

    300 inch pounds.

    Operation

    Once installed the hemispherical portion of the probe extends

    into the I.D. of the pipe approximately 3/8. When the sphere

    passes the switch, it forces the probe upward. This upward

    movement causes the ferrous body of the piston to enter the

    magnetic field of the proximity switch sensor. The result of the

    attracting forces causes the magnet in the sealed switch to

    move toward the ferrous piston causing the normally open

    contacts to close and complete the electrical circuit.

    Rev. 3/07

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-5 MODEL M-5DMODEL M-5T MODEL M-5TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Trouble Shooting

    Due to the limited number of moving parts, problems with the

    Mag-Tek detector switch are few. The most common problems

    can be attributed to one of the following:

    1. Switch damage - the switch may have been damaged by

    excessive electrical currents, or by dropping the switch. To

    check, remove the switch from the base, connect it to a

    volt/ohm meter and slide the piston into the lower portion

    of the switch. The switch should close and open as the

    piston is moved into and out of the switch. If it does not

    function properly, a replacement element is required.

    2. No indication - The sphere is not contacting the piston

    properly. Measure the O.D. of the scraper cup or sphere to

    be certain they are the proper diameter.

    3. No indication - Foreign material has accumulated above

    the piston in the sensing chamber preventing the piston

    from traveling upward. Remove the switch and clean the

    base of the switch and the spring. Check the bleed

    grooves in the piston to be sure they are clear.

    4. Switch is clean and checks out OK, the switch is sized

    properly, but the switch is intermittent or still does not

    function properly - misalignment of the base and hole causing

    the piston to bind or preventing it from extending into the pipe

    ID Recheck the base fit and probe insertion depth.

    Recommended Spare Parts

    Due to the simplicity of the switch, once it is installed the

    detector can operate indefinitely without the need for spare parts.

    Rev. 3/07

  • DPDT Contact Arrangement SPDT Contact Arrangement

    Wire Color Code:

    Circuit 1 RED-N/C RED-N/C

    BLUE-N/O BLUE-N/O

    BLACK-COM 1 BLACK-COM

    Circuit 2 RED w/STRIPE-N/C

    BLUE w/STRIPE-N/O

    BLACK w/STRIPE-COM 2

    GREEN-GROUND

    MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-5 MODEL M-5DMODEL M-5T MODEL M-5TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Specifications

    Contact: Model M-5, M-5T SPDT Environmentally SealedModel M-5D, M-5TD DPDT Environmentally Sealed

    Classification: CSA NRTL/C Class I, Division 1, Groups C and DHazardous Locations

    Rating: 2 Amps @ 240 V.A.C50 Milliamps @ 24 V.D.C.

    Repeatability: 0.002 units (Under identical operating conditions.)

    Response Time: 0.008 Seconds

    Temperature: -40F to +221F

    Pressure: 2220 Psi Max. Rating

    Weld on Base: Carbon Steel

    Spring: 302 Stainless Steel

    Piston: 416 Stainless Steel

    Body: 303 Stainless Steel

    0-Ring: Viton

    Conduit Opening: 1/2" FNPT for SPDT3/4" FNPT for DPDT

    Rev. 3/07

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-6 MODEL M-6DMODEL M-6T MODEL M-6TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    MAG-TEK MODEL M-6

    Patent No.US 6,789407 B1

    Rev. 3/07

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-6 MODEL M-6DMODEL M-6T MODEL M-6TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    General Information

    Mag-Tek features a pressure balanced, piston actuated, proximity

    switch with no dynamic seals. The switch is factory sealed, with

    no field adjustment, eliminating the chance of slipping from the

    original setting. The hemispherical shape of the piston allows

    either uni-directional or bi-directional operation. The detector

    switch is manufactured from stainless steel and designed for

    either above ground or below ground applications. Once

    installed the Mag-Tek has only one moving part, the pressure-

    balanced piston, thus allowing continuous, maintenance free,

    and accurate operation. Mag-Tek switches are also interchange-

    able with most other brands of switch mountings.

    Installation Instructions

    The standard M-6 Mag-Tek detector switch is designed for instal-

    lation on pipe having a nominal wall thickness of 0.375 inches

    or less. If the Mag-Tek is to be used on pipe having a wall thick-

    ness greater than 0.375 inches, be sure to specify when ordering.

    1. Select the desired locations on the pipe for the Mag-Tek

    detector switches. These points are usually, but not

    necessarily, on top of the pipe.

    2. Drill a 7/8 diameter hole at each point. Care should be

    taken to keep the drill bit centered and perpendicular to

    the pipe.

    3. All drill cuttings should be removed from inside the pipe.

    If, due to design, this cannot readily be done with a cloth

    or a stream of air, it can usually be done with a small

    mechanics extension type, hand-held magnet inserted

    through the 7/8 drilled hole.

    4. The inside of the drilled hole should be rounded or

    chamfered with a file or stone to remove sharp edges.

    5. Carefully center the base plate over the 7/8 diameter hole

    in the pipe, taking care to orient the base plate properly so

    that it is level with the pipe. Dimension from face of base

    plate to outside of pipe must be 2 3/8. This will leave a

    gap of approximately 1/8 for welding. Caution: The

    orientation of base plate to pipe is critical for proper

    switch operation and any misalignment may cause

    switch to malfunction. We stongly recommend the use

    of an alignment tool available from the factory.

    6. With the base plate positioned as described in paragraph 5

    above, lightly tack weld base plate to the pipe. Do the

    following checks before proceeding.

    A. Base plate is still centered over hole, and level with the pipe.

    B. The dimension from face of base plate to pipe still measures

    2 3/8

    Once all above is confirmed, complete the seal welding with

    required passes. Do not allow weld splatter or arc on the

    switch mounting face of the base plate. If Mag-Tek detector

    switches are to be installed on a prover after it has been

    internally coated, care should be taken to minimize the weld

    heat. It is suggested the weld be cooled from time to time with

    wet rags or other means. Filling the prover barrel with water, if

    practical, prior to welding, will help to further minimize

    possible damage to the internal coating.

    7. Check mounting face to make sure it is free from burrs and

    weld splatter. DO NOT PAINT the face of the mounting plate.

    8. Mount switch on base with (5) 3/8 cap screws.

    Recommended torque 240 inch pounds. Maximum torque

    300 inch pounds.

    Operation

    Once installed the hemispherical portion of the probe extends

    into the I.D. of the pipe approximately 3/8. When the sphere

    passes the switch, it forces the probe upward. This upward

    movement causes the ferrous body of the piston to enter the

    magnetic field of the proximity switch sensor. The result of the

    attracting forces causes the magnet in the sealed switch to

    move toward the ferrous piston causing the normally open

    contacts to close and complete the electrical circuit.

    Rev. 3/07

  • MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-6 MODEL M-6DMODEL M-6T MODEL M-6TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Trouble Shooting

    Due to the limited number of moving parts, problems with the

    Mag-Tek detector switch are few. The most common problems

    can be attributed to one of the following:

    1. Switch damage - the switch may have been damaged by

    excessive electrical currents, or by dropping the switch. To

    check, remove the switch from the base, connect it to a

    volt/ohm meter and slide the piston into the lower portion

    of the switch. The switch should close and open as the

    piston is moved into and out of the switch. If it does not

    function properly, a replacement element is required.

    2. No indication - The sphere is not contacting the piston

    properly. Measure the O.D. of the scraper cup or sphere to

    be certain they are the proper diameter.

    3. No indication - Foreign material has accumulated above

    the piston in the sensing chamber preventing the piston

    from traveling upward. Remove the switch and clean the

    base of the switch and the spring. Check the bleed

    grooves in the piston to be sure they are clear.

    4. Switch is clean and checks out OK, the switch is sized

    properly, but the switch is intermittent or still does not

    function properly - misalignment of the base and hole causing

    the piston to bind or preventing it from extending into the pipe

    ID Recheck the base fit and probe insertion depth.

    Recommended Spare Parts

    Due to the simplicity of the switch, once it is installed the

    detector can operate indefinitely without the need for spare parts.

    Rev. 3/07

  • DPDT Contact Arrangement SPDT Contact Arrangement

    Wire Color Code:

    Circuit 1 RED-N/C RED-N/C

    BLUE-N/O BLUE-N/O

    BLACK-COM 1 BLACK-COM

    Circuit 2 RED w/STRIPE-N/C

    BLUE w/STRIPE-N/O

    BLACK w/STRIPE-COM 2

    GREEN-GROUND

    MAG-TEK SPHEREDETECTOR SWITCHES

    MODEL M-6 MODEL M-6DMODEL M-6T MODEL M-6TD

    INSTALLATION, OPERATION &MAINTENANCE INSTRUCTIONS

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Specifications

    Contact: Model M-6, M-6T SPDT Environmentally SealedModel M-6D, M-6TD DPDT Environmentally Sealed

    Classification: CSA NRTL/C Class I, Division 1, Groups C and DHazardous Locations

    Rating: 2 Amps @ 240 V.A.C50 Milliamps @ 24 V.D.C.

    Repeatability: 0.002 units (Under identical operating conditions.)

    Response Time: 0.008 Seconds

    Temperature: -40F to +221F

    Pressure: 2220 Psi Max. Rating

    Weld on Base: Carbon Steel

    Spring: 302 Stainless Steel

    Piston: 416 Stainless Steel

    Body: 303 Stainless Steel

    0-Ring: Viton

    Conduit Opening: 1/2" FNPT for SPDT3/4" FNPT for DPDT

    Rev. 3/07

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems& L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom Fabrication

    Mag-Tek SphereDetector Switches

  • WeamcoMetric designs, fabricates, and delivers all types and sizes of metering systems forthe pipeline, offshore, and petrochemical industries.

    These metering units can be a simple single run PD Meter Loading Skid to large multiplemeter run pipeline custody transfer skids with on-skid provers and sampling.

    WeamcoMetric also manufactures Lease Automatic Custody Transfer (LACT) Units for crudeoil applications. All units are custom designed to meet your application and comply withAPI Specification 11N.

    Some photos are provided to show examples of metering systems we have supplied tovarious customers specifications. All of our systems are Project Managed from proposaland design concept, to shipment, with approval drawings, purchasing, fabrication,calibration and testing in between, which ensures quality and on-time performance.

    (918) 445-1141(800) 331-3790

    Fax: (918) 445-4617 www.weamco.com

    Metering Sytems & LACT Units

    Bulletin PR307

  • Permanent Strainers

    Temporary Strainers

    Line Blinds

    Coupon Holders

    Sampling Equipment

    Pipeline Accessories

    Meter Provers

    Metering Systems

    L.A.C.T. Units

    Toll Free 800-331-3790Oklahoma Home Office 918-445-1141

    Fax 918-445-4617www.weamco.com

    Custom FabricationMag-


Recommended