Passive Design Feature 1 - Basic building design A. Building Orientation
According to the Malaysian Standard 1525 (MS1525), one of the passive design strategy is
orientation of building. The GEO building is considered well orientated because its long facades are
facing north and south, and short facades are facing east and west. (Department of Standards
Malaysia, 2007, p. 5) With this orientation direct sunlight only shines at the shorter facades in the
morning and evening.
West Facade
N
North Facade
South Facade
East Facade
Figure 1 Floor Plan
Figure 2 Geo building Sun Path
Page | 14
To avoid the entering of direct sunlight into the facades facing east and west, the building is
designed to have minimal windows at these two short facades. On the other hand, the longer
facades are filled with windows to allow maximum amount of daylighting to enter the building.
Natural lighting that enters the building through the long facades are diffused light, not direct
sunlight. Diffused light has lesser thermal impact compared to direct sunlight. Hence, with this
design strategy, the building is able to achieve higher thermal comfort. (Ng & Akasah, 2011, p.)
Figure 4 the north and south facade is filled with windows to allow daylighting
(Source: http://www.greenbuildingindex.org/why-green-buildings.html)
Figure 3 The east and west facades have minimal window (Source: http://wikimapia.org/619168/PTM-GEO-Building)
Page | 15
B. Building Configuration
Another passive design strategy mentioned in the MS1525 is the configuration of the
building. (Department of Standards Malaysia, 2007, p. 4) The GEO building has a “step-in” design.
The step-in design enables the building to be self-shaded by its own structure. (Ng & Akasah, 2011,
p. 221) In the section, it can be seen that the width of the floor increases as we go up the floors. This
is done to control glaring from direct sunlight. There are also extended walls that creates a vertical
shading system. Overhangs are also installed to aid the shading and glaring control. The extended
walls and the overhangs create an egg-crate-like design which helps the building to be well-
shaded.
Figure 5 Section of the building
Figure 6 Extended vertical walls at the North Facade
North South
Page | 16
The images below are created using Ecotect. The date was set to be 22nd September and the
façade used is the North facade. From the images, it can be seen that the GEO building is well-
shaded throughout the day. The orientation of the building and the building configuration had
contributed to the success of the shading system.
Figure 9 Shading at 6pm
Figure 8 Shading at 2pm
Figure 7 Shading at 10am
Page | 17
C. Insulation
Referring to the MS1525, the general requirement of the building envelope is to be able to
block out heat gain into buildings via conduction and solar radiation. (Department of Standards
Malaysia, 2007, p. 10) To achieve this, insulations are installed in the walls and the roof of the
building. The internal walls are installed with a layer of rock wool whereas the external walls are
installed with two layers of rock wool. This is because the external walls receive greater thermal
effects compared to the internal walls. (Ng & Akasah, 2011, p. 215)
The roofs are also insulated to reduce thermal transfer. The slanting roofs are insulated with
Mineral wool due to its excellent thermal insulation. However, mineral wool is vapour-permeable
causing it to be unsuitable for flat roof insulation. Hence, Styrofoam insulation is used in flat roofs. (Ng & Akasah, 2011, p. 215)
With the roof and wall insulations, the overall thermal transfer value (OTTV) of the building
can be reduced, hence achieving better thermal comfort. With the aid of air-conditioning and the
radiant cooling, the average temperature of the interior of the building is 24°C to 26°C. (Ng &
Akasah, 2011, p. 225)
Rock wool insulation
Wire Mesh
Cement mortar
Figure 10 internal wall insulation
Rock wool insulation
Wire Mesh
Cement mortar
Figure 11 external wall insulation
Figure 12 installation of Styrofoam during construction of the roof (Source: Malaysia Green Technology Corporation, 2010)
Figure 13 Mineral wool layer is installed on the slanting roof (Source: Malaysia Green Technology Corporation, 2010)
Figure 14 Indoor temperatures (Source : Yoong, 2008, p. 67)
Page | 18
Passive Design Feature 2 - Windows and Roof Light To minimize the use of artificial lighting, windows are placed along the long facades and roof
lights are placed on the top floor for natural lighting to reach the interior. The GEO building uses an
open space concept where the workstations are placed near the windows and use of partition is
minimal to enable light to reach all workstations. (Pusat Tenaga Malaysia, 2008)
The MS1525 also touched on the daylighting. It is mentioned that when designing with the
emphasis of natural daylighting, the solar gain has to be considered. (Department of Standards
Malaysia, 2007, p. 5) This can be controlled by using windows with suitable solar and thermal
properties and external and internal shading devices.
A. Windows
Double glazed windows are used to reduce heat gain in the interior. These windows
reflect ultraviolet and infrared radiation from the building’s exterior surface, reducing the heat transfer by 25%. With the use of radiant cooling through the floor slab and air-conditioning,
there is a maximum difference of 7°C between the indoor and outdoor temperatures. (Yoong, 2008,
p. 67)
The windows also use a unique system to avoid emission of direct sunlight into the
building. Overhangs are installed for shading purposes. On the overhangs, there are
Double pane glass
Argon Gas Gap
Indoor
Figure 16 Double Glazing Window
Reflected Heat
Outdoor
Figure 15 Floor Plan: Workstations are placed near windows.
N
Page | 19
reflective mirrors to reflect the diffused daylight into the building. Blinds are installed on the
upper windows to direct the light upwards to the internal daylight reflector. These reflectors
enables diffused daylight to be thrown deeper into the building. The blinds also act as a
barrier direct sunlight which comes from the above. By preventing direct sunlight from
entering the interior, heat gain in the building can be reduced greatly. The lower surface of
the blinds are white with low gloss whereas the upper surface of the blinds are reflective
aluminium to allow reflection. (Muhammad, 2014)
Blinds
Internal
daylight
reflector
Reflective mirror
Outdoor Indoor
Figure 17 pathway of diffused light through window
Figure 18 Overhangs from the exterior Figure 19 Internal Daylight Reflector (Source: Green Tech Malaysia, 2014)
Page | 20
B. Roof Light
On the highest floor, roof lights are installed to distribute diffused natural lighting which
carry less heat energy compared to direct sunlight. This is achieved through the installation
of mirror reflectors on the insides of the structure which serve to magnify light. A better
thermal comfort is achieve as direct sunlight do not enter the building. (Muhammad, 2014)
Direct Sunlight
Diffused Light Mirror Reflector
Figure 20 Pathway of diffused light from Roof light
Figure 21 Roof light from the roof (Source:http://www.uniten.edu.my/newhome/uplo
aded/coe/arsepe/2008/UNITEN ARSEPE 08 L24.pdf) Figure 22 Roof light from the resource centre