+ All Categories
Home > Documents > Fire Alarm Cables - TC Life Safety · Circuit Integrity fire alarm cables. For more detailed...

Fire Alarm Cables - TC Life Safety · Circuit Integrity fire alarm cables. For more detailed...

Date post: 09-Sep-2018
Category:
Upload: phungdieu
View: 234 times
Download: 0 times
Share this document with a friend
14
is one of the original and leading manufactures of Fire Alarm cables in the world. Security and Alarm cables are a vital part of the building and construction industries. Security and FireAlarm cables have been one of the most trusted names in the Security industry. offers the broadest line of fire alarm cables in the industry! Our fire alarm cables are designed to meet Conventional and Addressable system specifications. also offers Circuit Integrity fire alarm cables. For more detailed information on our fire alarm cables, contact our Customer Service Department at , or e-mail us at: . Information can also be found on our website: 47 Mini Index Power-Limited Cables FPLR/ Unshielded ……………………………………………………… FPLR/ Shielded ………………………………………………………… FPL- Low Cap/ Unshielded & Shielded…………………………… FPL/ One and Two Conductor………………………………………… FPLP/ Unshielded …………………………………………………… FPLP/ Shielded ……………………………………………………… FPLP/ Shielded Data Grade……………………………………… Non Power-Limited Cables NPLF/ Unshielded …………………………………………………… NPLF/ Shielded ……………………………………………………… NPLFP Plenum/ Shielded & Unshielded ……………………… Circuit Integrity Circuit Integrity in Conduit (CIC)/ Shielded………………… Circuit Integrity in Conduit (CIC)/ Unshielded……………… Circuit Integrity (CI)/ Shielded………………………………… Circuit Integrity (CI)/ Unshielded……………………………… 48 49 50 51 52 53 53 Over 95% of West Penn Wire cables are RoHS Compliant. For a detailed specification on individual products, contact our engineering department. 54 55 56 57 58 59 60 Fire Alarm Cables
Transcript

is one of the original and leadingmanufactures of Fire Alarm cables in the world.Security and Alarm cables are a vital part of thebuilding and construction industries.

Security and FireAlarm cables have been oneof the most trusted names in the Security industry.

offers the broadest line of firealarm cables in the industry! Our fire alarm cablesare designed to meet Conventional and Addressable system specifications. also offersCircuit Integrity fire alarm cables.

For more detailed information on our fire alarmcables, contact our Customer Service Department at

, or e-mail us at: . Information can also

be found on our website:

47

Mini Index

Power-Limited CablesFPLR/ Unshielded ………………………………………………………FPLR/ Shielded …………………………………………………………FPL- Low Cap/ Unshielded & Shielded……………………………FPL/ One and Two Conductor…………………………………………FPLP/ Unshielded ……………………………………………………FPLP/ Shielded ………………………………………………………FPLP/ Shielded Data Grade………………………………………

Non Power-Limited CablesNPLF/ Unshielded ……………………………………………………NPLF/ Shielded ………………………………………………………NPLFP Plenum/ Shielded & Unshielded ………………………

Circuit IntegrityCircuit Integrity in Conduit (CIC)/ Shielded…………………Circuit Integrity in Conduit (CIC)/ Unshielded………………Circuit Integrity (CI)/ Shielded…………………………………Circuit Integrity (CI)/ Unshielded………………………………

48495051525353

Over 95% of West Penn Wire cables are RoHSCompliant. For a detailed specification on individualproducts, contact our engineering department.

545556

57585960

Fire Alarm Cables

Applications:Indoor for:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesPower-Limited Multiple Conductor/

Unshielded

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

980 1Pair

18 AWGSolid

6.5 Ω/Mft

PVC.010 None

PVC.015 .146 29 pf/ft*

RD, BK,WH, YE

982 4 18 AWGSolid

6.5 Ω/Mft

PVC.010 None

PVC.015 .178 29 pf/ft*

RD, BK,WH, YE

990 1Pair

16 AWGSolid

4.1 Ω/Mft

PVC.010

None PVC.015

.155 32 pf/ft* RD, BK,WH, YE

Standard spool size 1000ft.

Rating:• NEC Type FPLR• (UL) or (ETL)us Listed• Meets 300V requirements as specified in the NEC• Flame Rating: UL1666

Description:• ASTM bare copper • PVC insulation • Twisted pair or cabled

construction • Overall PVC jacket

992 416 AWG

Solid4.1 Ω/Mft

PVC.010

None PVC.015

.203 32 pf/ft* Red

994 1Pair

14 AWGSolid

2.6 Ω/Mft

PVC.012

None PVC.015

.195 35 pf/ft*RD, BK,BL, WH,

YE

700 414 AWG

Solid2.6 Ω/Mft

PVC.012

None PVC.015

.240 35 pf/ft* Red

998 1Pair

12 AWGSolid

1.8 Ω/Mft

PVC.012 None

PVC.015 .225 45 pf/ft* Red

Color Code- See page 49

48

Inches Inches Inches

Special Notes:• Selected Plenum Versions see pages 52• Selected Indoor/Outdoor Aquaseal Water

Resistant® Versions see pages 43.• Orange rip cord under jacket

990SNew

1Pair

16 AWGStrd.

4.1 Ω/Mft

PVC.010 None

PVC.015 .155 32 pf/ft* Red

994SNew

1Pair

14 AWGStrd.

2.6 Ω/Mft

PVC.012

None PVC.015

.195 35 pf/ft* Red

998SNew

1Pair

12 AWGStrd.

1.8 Ω/Mft

PVC.012

None PVC.015

.225 45 pf/ft* Red

Fire Alarm Cables

* Capacitance between conductors.

Applications:Indoor for:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesPower-Limited Multiple Conductor/ Shielded

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding& %

CoverageJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

1083 422 AWG

Solid 17.5 Ω/Mft

PVC.010

Al. Foil100%

PVC.015 .146

54 pf/ft*97 pf/ft** Red

975 1Pair

18 AWGSolid

6.5 Ω/Mft

PVC.010

Al. Foil100%

PVC.015 .149

73 pf/ft*133 pf/ft** Red

991 1Pair

16 AWGSolid

4.1 Ω/Mft

PVC.010

Al. Foil100%

PVC.015 .160

82 pf/ft*148 pf/ft**

RD, BK,WH, YE

993 416 AWG

Solid4.1 Ω/Mft

PVC.010

Al. Foil100%

PVC.015 .207

82 pf/ft*148 pf/ft** Red

995 1Pair

14 AWGSolid

2.6 Ω/Mft

PVC.012

Al. Foil100%

PVC.015

.201 84 pf/ft*151 pf/ft**

Red

Description:• ASTM bare copper • PVC insulation • Twisted pair or cabled

construction • Overall shield 100% coverage of aluminum polyester foil binders as required with TC drain wire

• Overall PVC jacket

Rating:• NEC Type FPLR• (UL) or (ETL)us Listed• Meets 300V requirements as specified in the NEC• Flame Rating: UL1666Standard spool size 1000ft.

* Capacitance between conductors.** Capacitance between one conductor and

the other connected to the shield

999 1Pair

12 AWGSolid

1.8 Ω/Mft

PVC.012`

Al. Foil100%

PVC.015

.230 96 pf/ft*173 pf/ft**

Red

49

Special Notes:• Selected Plenum Versions see pages 53• Selected Indoor/Outdoor Aquaseal Water

Resistant® Versions see pages 44• Orange rip cord under jacket

Inches Inches Inches

Fire Alarm Cables

Color Code

AllCables

1.Black, 2. Red, 3. Brown, 4. Blue

JACKET: RD-Red, BK-Black,WH- White, YE-Yellow

977 418 AWG

Solid6.5 Ω/Mft

PVC.010

Al. Foil100%

PVC.015

.182 73 pf/ft*133 pf/ft**

Red

Applications:Indoor data cable for:• Data Circuits• Addressable Systems• Initiating Circuits• Notification Circuits

Power-Limited / Unshielded

Addressable Systems/ Data Cable

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

D980 1Pair

18 AWGSolid

6.5 Ω/Mft

Polyolefin.015 None

PVC.030 .182 16 pf/ft* Red

D982 418 AWG

Solid6.5 Ω/Mft

Polyolefin.015

NonePVC.030 .230 16 pf/ft* Red

D990 1Pair

16 AWGSolid

4.1 Ω/Mft

Polyolefin.015 None

PVC.030 .223 18 pf/ft* Red

Standard spool size 1000ft.

Rating:• NEC Type FPL• (UL) or (ETL)us Listed• Meets 300V requirements as specified in the NEC• Flame Rating: UL1685

Description:• ASTM bare copper • Polyolefin insulation • Short overall twist

lengths • Unshielded construction • Overall PVC jacket

Power-Limited / Shielded

Addressable Systems/ Data Cable

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% CoverageJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

D975 1Pair

18 AWGSolid

6.5 Ω/MftPolyolefin

.015Al. Foil

100%

PVC.030

.210 25 pf/ft*45 pf/ft**

Red

D991 1Pair

16 AWGSolid

4.1 Ω/Mft

Polyolefin.015

Al. Foil100%

PVC.030

.226 30 pf/ft*54 pf/ft**

Red

D995 1Pair

14 AWGSolid

2.6 Ω/Mft

Polyolefin.020 Al. Foil

100% PVC.030

.262 30 pf/ft*54 pf/ft**

Red

Description:• ASTM bare copper • Polyolefin insulation • Short overall twist

length • Overall shield 100% coverage of aluminum polyesterfoil with TC drain wire • Overall PVC jacket

Standard spool size 1000ft.

* Capacitance between conductors.** Capacitance between one conductor and

the other connected to the shield

50

Inches Inches Inches

Special Notes:• Selected Plenum Versions see pages 53• Orange rip cord under jacket

Inches Inches Inches

Fire Alarm Cables

Color Code

AllCables

1.Black, 2. Red, 3. Brown, 4. Blue

JACKET: Red

* Capacitance between conductors.

Do not forget that West Penn Wire offers a com-plete and comprehensive line of:

• Connectors• Cable Assemblies• Installation Kits• Fiber Optic Accessories• A/V Wall Plates

800-245-4964 51

Applications:Indoor for:• Power-Limited Protective Circuits

Fire Alarm CablesPower-Limited One &Two Conductor/ Parallel

Description:• ASTM bare copper • PVC insulation • Two conductor parallel features- PERFECTSTRIPE®

Rating:• NEC Type FPL• (UL) or (ETL)us Listed• Flame Rating: UL1685

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

970 218 AWG

Solid6.5 Ω/Mft

PVC.032

None -- .104x.204 --RD, WH,

OR, BN, BL,BK

971 216 AWG

Solid4.1 Ω/Mft

PVC.032 None -- .115x.225 --

RD, WH,BK

972 214 AWG

Solid2.6 Ω/Mft

PVC.032 None -- .128x.250 --

RD, WH,BK

974 212 AWG

Solid1.8 Ω/Mft

PVC.032

None -- .146x.300 -- RD, BK

Inches Inches Inches

Colors

JacketColors

RD-Red, BK-BlackWH- White, YE-Yellow, OR-Orange,

BN-Brown

Fire Alarm Cables

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

962 114AWG

Solid2.6 Ω/Mft

PVC.020 None -- .104 --

BK, GN, BN,WH, RD,OR, YE

Inches Inches Inches

Single Conductor

Parallel Construction- Two Conductor

Applications:Indoor within ducts,plenums and other spacesused for environmental air:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesPower-Limited/ Unshielded

Plenecon II ® Extra Flexible

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

60980B 1Pair

18 AWGSolid

6.5 Ω/Mft.010 None .015 .142 29 pf/ft* Red

60982B 418 AWG

Solid6.5 Ω/Mft

.010 None .015 .175 29 pf/ft* Red

60991B 1Pair

16 AWGSolid

4.1 Ω/Mft.010 None .015 .161 32 pf/ft* Red

60164B 416 AWG

Solid4.1 Ω/Mft

.010 None .015 .220 32 pf/ft* Red

60993B 1Pair

14 AWGSolid

2.6 Ω/Mft.012 None .015 .191 35 pf/ft* Red

60700B 414 AWG

Solid2.6 Ω/Mft

.012 None .015 .252 35 pf/ft* Red

60995B 1Pair

12 AWGSolid

1.8 Ω/Mft.012 None .015 .225 45 pf/ft* Red

Standard spool size 1000ft.

Rating:• NEC Type FPLP• (UL) or (ETL)us Listed• Meets 300V requirements as specified in the NEC• Flame Rating: NFPA-262 Smoke & Flame Test

Description:• ASTM bare copper • Polymer alloy insulation • Twisted pair or cabled construction • Flexible plenum jacket

52

Special Notes:• Plenum Installation Precautions see

Technical Reference Section Page 192

Inches Inches Inches

Fire Alarm Plenum Cables

Color Code

AllCables

1.Black, 2. Red, 3. Brown, 4. Blue

JACKET: Red

* Capacitance between conductors.

Applications:Indoor within ducts,plenums and other spaces used for environmental air:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesPower-Limited / Shielded

Plenecon II ® Extra Flexible

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% CoverageJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

60975B 1Pair

18 AWGSolid

6.5 Ω/Mft.010 Al. Foil

100% .015 .148 54 pf/ft*

97 pf/ft**Red

60977B 418 AWG

Solid6.5 Ω/Mft

.010Al. Foil

100% .015 .17854 pf/ft*97 pf/ft** Red

60990B 1Pair

16 AWGSolid

4.1 Ω/Mft.010

Al. Foil100% .015 .166

61 pf/ft*110 pf/ft** Red

603164B 416 AWG

Solid4.1 Ω/Mft

.010Al. Foil

100% .015 .21061 pf/ft*

110 pf/ft** Red

60992B 1Pair

14 AWGSolid

2.6 Ω/Mft.012

Al. Foil100% .015 .198

84 pf/ft*151 pf/ft** Red

Description:• ASTM bare copper • Polymer Alloy insulation • Twisted pair or

cabled construction • Overall shield 100% coverage of aluminumpolyester foil with TC drain wire • Flexible plenum jacket

Rating:• NEC Type FPLP• (UL) or (ETL)us Listed• Meets 300V requirements as specified in the NEC• Flame Rating: NFPA-262 Smoke & Flame TestStandard spool size 1000ft.

* Capacitance between conductors.** Capacitance between one conductor and

the other connected to the shield

60994B 1Pair

12 AWGSolid

1.8 Ω/Mft.012 Al. Foil

100% .015 .224 96 pf/ft*

173 pf/ft**Red

D60975^

1Pair

18 AWGSolid

6.5 Ω/Mft

.012 Al. Foil100%

.015 .165 25 pf/ft*45 pf/ft**

Red

D60990^

1Pair

16 AWGSolid

4.1 Ω/Mft

.015 Al. Foil100% .015 .184

30 pf/ft*54 pf/ft** Red

DATA GRADE PLENUM

^ - Data grade versions for addressable systems contain LowLoss Insulation and Overall FlexiblePlenum Jacket.

53

Special Notes:• Plenum Installation Precautions see

Technical Reference Section Page 192

Inches Inches Inches

Fire Alarm Plenum Cables

Color Code

AllCables

1.Black, 2. Red, 3. Brown, 4. Blue

JACKET: Red

Applications:Indoor for:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesNonpower-Limited/ Unshielded

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

1990 1Pair

16 AWGSolid

4.1 Ω/Mft

PVC.016

Nylon.005

NonePVC.037 .252 -- Red

Standard spool size 1000ft.

Rating:• NEC Type NPLF• (UL) or (ETL)us Listed• Meets 150V requirements as specified in the NEC• Flame Rating: UL1685

Description:• ASTM bare copper • PVC insulation with Nylon • Twisted pair or

cabled construction • Overall PVC jacket

1994 1Pair

14 AWGSolid

2.6 Ω/Mft

PVC.016

Nylon.005

None PVC.037

.278 -- Red

54

Special Notes:• Selected Plenum Versions see pages 56• Orange rip cord under jacket

Inches Inches Inches

Fire Alarm Cables

Color Code

AllCables

1.Black, 2. Red

JACKET: Red

Applications:Indoor for:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesNonPower-Limited/ Shielded

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% Coverage

Jacket Type&

ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

1975 1Pair

18 AWGSolid

6.5 Ω/Mft

PVC.016

Nylon.005

Al. Foil100%

PVC.037 .244

52 pf/ft*94 pf/ft** Red

1991 1Pair

16 AWGSolid

4.1 Ω/Mft

PVC.016

Nylon.005

Al. Foil100%

PVC.037 .264

57 pf/ft*103 pf/ft** Red

1995 1Pair

14 AWGSolid

2.6 Ω/Mft

PVC.016

Nylon.005

Al. Foil100%

PVC.037

.284 64 pf/ft*115 pf/ft**

Red

Description:• ASTM bare copper • PVC insulation with Nylon • Twisted pair or

cabled construction • Overall shield 100% coverage of aluminumpolyester foil with TC drain wire • Overall PVC jacket

Rating:• NEC Type NPLF• (UL) or (ETL)us Listed• Flame Rating: UL1685

Standard spool size 1000ft.

1997 414 AWG

Solid2.6 Ω/Mft

PVC.016

Nylon.005

Al. Foil100%

PVC.042 .388

64 pf/ft*115 pf/ft** Red

1999 1Pair

12 AWGSolid

1.8 Ω/Mft

PVC.016

Nylon.005

Al. Foil100%

PVC.042 .328

73 pf/ft*131 pf/ft** Red

55

* Capacitance between conductors.** Capacitance between one conductor and

the other connected to the shield

Inches Inches Inches

Special Notes:• Selected Plenum Versions see pages 56• Orange rip cord under jacket

Fire Alarm Cables

Color Code

AllCables

1.Black, 2. Red, 3. Brown, 4. Blue

JACKET: Red

Applications:Indoor for:• Audio Circuits• Control Circuits• Initiating Circuits• Notification Circuits

Fire Alarm CablesNonpower-Limited/ Shielded & Unshielded

Plenum

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% CoverageJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

251980† 1Pair

18 AWGSolid

6.5 Ω/Mft

Fluoro-polymer

.020None .010 .185 -- Red

251975 1Pair

18 AWGSolid

6.5 Ω/Mft

Fluoro-polymer

.020

Al. Foil100%

.010 .195 -- Red

251991 1Pair

16 AWGSolid

4.1 Ω/Mft

Fluoro-polymer

.020

Al. Foil100% .010 .214 -- Red

Standard spool size 1000ft.

Rating:• NEC Type NPLFP• (UL) or (ETL)us Listed• Meets 150V requirements as specified in the NEC• Flame Rating: NFPA-262 Smoke & Flame Test

Description:• ASTM bare copper • Fluoroplymer insulation • Twisted pair or cabled

construction • Unshielded and Shielded Versions (Shielded versions)100% coverage of aluminum polyester foil with TC drain wire

• Overall fluoropolymer jacket

251994† 1Pair

14 AWGSolid

2.6 Ω/Mft

Fluoro-polymer

.020None .010 .210 -- Red

251995 1Pair

14 AWGSolid

2.6 Ω/Mft

Fluoro-polymer

.020

Al. Foil100%

.010 .220 -- Red

56

Special Notes:† Unshielded version• Plenum Installation Precautions see

Technical Reference Section Page 192

Inches Inches Inches

Fire Alarm Plenum Cables

Color Code

AllCables

1.Black, 2. Red

JACKET: Red

Applications:Indoor for:• Circuit Integrity• Fire Alarm Circuit Integrity• Survivability• Survivability from attack by fire

Circuit Integrity in Conduit/ Shielded

(CIC) - Riser Rated

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% CoverageJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

5200FZ 216 AWG

7x244.0 Ω/Mft

CSR.035

Al. Foil100%

FRPE.056

.37 22pf/ft* Red

5100FZ 214 AWG

7x222.5 Ω/Mft

CSR.035 Al. Foil

100%

FRPE.056 .41 26pf/ft* Red

5000FZ 212 AWG

7x201.6 Ω/Mft

CSR.035

Al. Foil100%

FRPE.056 .44 27pf/ft* Red

Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)

Insulation • Twisted pair or cabled construction • Overall shield100% coverage of aluminum polyester foil with TCdrain wire • Overall FRPE Low-Smoke, Non-Halogen Jacket

Rating:• NEC Type FPLR• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL1666,

UL2196 - 2 Hour Flame Test ( in conduit only)Standard spool size 1000ft.

5220FZ 216 AWG

Solid4.0 Ω/Mft

CSR.035 Al. Foil

100%

FRPE.056 .36 20pf/ft* Red

5222FZ 416 AWG

Solid4.0 Ω/Mft

CSR.035 Al. Foil

100%

FRPE.056 .41 16pf/ft* Red

5120FZ 214 AWG

Solid2.5 Ω/Mft

CSR.035

Al. Foil100%

FRPE.056

.38 23pf/ft* Red

Color Code

AllCables

Black, Red- 4 or more are Blackand numbered

JACKET: Red

57

Inches Inches Inches

Fire Alarm Cables

* Capacitance between conductors.

Special Notes:• CSR- Ceramifiable Silicon Rubber • FRPE- Flame Retardant Polyethylene

Rating:• NEC Type FPLR• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL 1666,

UL2196 - Two Hour Flame Test ( in conduit only)

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

5200UZ 216 AWG

7x244.0 Ω/Mft

CSR.035 None

FRPE.056 .37 16pf/ft* Red

5100UZ 214 AWG

7x222.5 Ω/Mft

CSR.035

None FRPE.056

.40 18pf/ft* Red

Circuit Integrity in Conduit/ Unshielded

Riser Rated - (CIC)

Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)

Insulation • Twisted pair or cabled construction • Overall FRPE Low-Smoke, Non-Halogen Jacket

Standard spool size 1000ft.

Applications:Indoor for:• Circuit Integrity• Fire Alarm Circuit Integrity• Survivability• Survivability from attack by fire

5220UZ 216 AWG

Solid4.0 Ω/Mft

CSR.035 None

FRPE.056 .35 15pf/ft* Red

5120UZ 214 AWG

Solid2.5 Ω/Mft

CSR.035 None

FRPE.056 .38 17pf/ft* Red

58

Color Code

AllCables

Black, Red

JACKET: Red

Inches Inches Inches

Fire Alarm Cables

Special Notes:• CSR- Ceramifiable Silicon Rubber • FRPE- Flame Retardant Polyethylene

* Capacitance between conductors.

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

Thickness

Shielding&

% CoveragJacket Type& Thickness

Nom.O.D.

NECType

Nom.Capacitance

JacketColor

5320FM 218 AWG

Solid5.9 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .31 -CI 27pf/ft* Red

5322FM 418 AWG

Solid5.9 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .36 -CI 27pf/ft* Red

5300FM 218 AWG

7x265.9 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .32 -CI 27pf/ft* Red

Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)

Insulation • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil with

TC drain wire • Overall FRPE Low-Smoke, Non Halogen Jacket

5302FM 418 AWG

7x265.9 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .37 -CI 27pf/ft* Red

Applications:Indoor for:• Circuit Integrity• Fire Alarm Circuit Integrity• Survivability• Survivability from attack by fire

Circuit Integrity/ Shielded

(CI) - Riser Rated

Rating:• NEC Type FPLR-CI• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL1666, UL2196 - 2 Hour Flame TestStandard spool size 1000ft.

5220FM 216 AWG

Solid4.0 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .33 -CI 31pf/ft* Red

5222FM 416 AWG

Solid4.0 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .38 -CI 31pf/ft* Red

5200FM 216 AWG

7x244.0 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .35 -CI 31pf/ft* Red

5120FM 214 AWG

Solid2.5 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .36 -CI 33pf/ft* Red

5122FM 414 AWG

Solid2.5 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .41 -CI 33pf/ft* Red

5100FM 214 AWG

7x222.5 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .38 -CI 33pf/ft* Red

5020FM 212 AWG

Solid1.6 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .39 -CI

37pf/ft*Red

5022FM 412 AWG

Solid1.6 Ω/Mft

CSR.034

Al. Foil100%

FRPE.045 .46 -CI 37pf/ft* Red

Notes: Color Code Pg. 60

59

Inches Inches Inches

Fire Alarm Cables

* Capacitance between conductors.

CatalogNo.

No. of Cond.

ConductorType &

Nom. D.C.R

InsulationType &

ThicknessShielding Jacket Type

& ThicknessNom.O.D.

NECType

Nom.Capacitance

JacketColor

5320UM 218 AWG

Solid5.9 Ω/Mft

CSR.034 None

FRPE.045 .31 -CI 17pf/ft* Red

5220UM 216 AWG

Solid4.0 Ω/Mft

CSR.034 None

FRPE.045 .33 -CI 19pf/ft* Red

5120UM 214 AWG

Solid2.5 Ω/Mft

CSR.034

None FRPE.045

.36 -CI 21pf/ft* Red

5020UM 212 AWG

Solid1.6 Ω/Mft

CSR.034 None

FRPE.045 .39 -CI 23pf/ft* Red

Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)

Insulation • Twisted pair or cabled construction • Overall FRPE Low-Smoke, Non-Halogen Jacket

Circuit Integrity / Unshielded

Riser Rated - (CI)

Applications:Indoor for:• Circuit Integrity• Fire Alarm Circuit Integrity• Survivability• Survivability from attack by fireRating:

• NEC Type FPLR-CI• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL 1666, UL2196- Two Hour Flame Test

Standard spool size 1000ft.

5322UM 418 AWG

Solid5.9 Ω/Mft

CSR.034

None FRPE.045

.35 -CI 17pf/ft* Red

5222UM 416 AWG

Solid4.0 Ω/Mft

CSR.034

None FRPE.045

.38 -CI 19pf/ft* Red

5122UM 414 AWG

Solid2.5 Ω/Mft

CSR.034 None

FRPE.045 .41 -CI 21pf/ft* Red

5022UM 412 AWG

Solid1.6 Ω/Mft

CSR.034 None

FRPE.045 .45 -CI 23pf/ft* Red

60

Color Code

AllCables

Black, Red- 4 or more are Blackand numbered

JACKET: Red

Inches Inches Inches

Fire Alarm Cables

* Capacitance between conductors.

Special Notes:• CSR- Ceramifiable Silicon Rubber • FRPE- Flame Retardant Polyethylene


Recommended