Fire detection equipment www.apollo-fire.co.uk PRODUCT CATALOGUE 2009
Transcript

Fire detection equipment

www.apollo-fire.co.uk

PRODUCT CATALOGUE 2009

Information in this catalogue is given in good faith, but Apollo Fire Detectors cannot be held responsible for any omissions or errors. The company reserves the right to change specifications of products at any time without prior notice.

Apollo Fire Detectors Ltd. has specialised in the design and

manufacture of high quality fire detection products since

1980. In that time, the company has broadened its capability

from a straightforward focus on conventional fire detectors

to include the manufacture of sophisticated analogue

addressable detectors and interfaces for monitoring and

controlling equipment in fire protection systems.

Apollo applies the most modern production techniques and has

invested in sophisticated manufacturing equipment to ensure

consistent high quality products and fast response to customer

requirements. Through planned expansion, Apollo has reached a

leading position in the market for professional fire detectors and

exports over half of its production to countries around the world.

In 2007, Apollo unveiled a new brand identity, further cementing

its position as a world class fire solutions provider.

Based in Havant, Hampshire, Apollo operates from one site. All

departments - Research and Development, Sales and Marketing,

Manufacturing and Finance are located here.

Apollo is a Halma company. Halma is a holding company for over 40

subsidiaries worldwide, all engaged in specialist engineering activities.

Why Choose Apollo?• Largestindependentsmokedetector

manufacturerintheworld

• Certifiedtoallkeyinternationalapprovals

• ThebestpeopleworkforApollo

• Trustworthy,integrity&supportive

• Localisedcustomerserviceworldwide

• Exstockdelivery

• 100%reliability,100%tested

• Open,digitalprotocol

• Forwardsandbackwardsproductcompatibility

• WorldClassFireSolutions

Apollo - The Partner of Choice

Apollo Fire Detectors Ltd. has specialised in the design and

controlling equipment in fire protection systems.

Apollo applies the most modern production techniques

invested in sophisticated manufacturing equipment to ensure

consistent high quality products and fast response to customer

requirements. Through planned expansion, Apollo has reached a

leading position in the market for professional fire detectors and

exports over half of its production to countries around the world.

In 2007, Apollo unveiled a new brand identity, further cementing

its position as a world class fire solutions provider.

• World

Apollo - The Partner of Choice

ByAppointmenttoHerMajestyTheQueen

ManufacturersofFireDetection&AlarmProducts

ApolloFireDetectorsLimitedHampshire

Contents

4

6

8

24

34

40

44

How do Detectors Work?

New Products

Intelligent Fire DetectionDiscovery, XP95

Conventional Fire DetectionOrbis, Series 65

Two-wire technologyAlarmSense

Wireless technologyXPander

Specialist DetectorsFlame, Beam & Duct Detectors

Audio Visual SignallingSounders, Beacons, Sounder Beacons, Sounder Beacon Bases

InterfacesIsolated, Non-Isolated, Mini, DIN-Rail

52

68

78

82

86

94

102

116

120

122

129

Manual Call Points

Mounting Accessories

MarineDiscovery, Orbis

Intrinsically SafeXP95, Orbis

ULXP95A, Series 65A, Discovery UL

Test Equipment and Maintenance

Additional ServicesLoop Calculator, Training

Approvals

Index

4 How do Detectors Work?

How do Detectors Work?

Ionisation smoke detector

The sensing part of the detector consists of two

chambers - an open, outer chamber and a semi-sealed

reference chamber within. Mounted in the reference

chamber is a low activity radioactive foil of Americium

241 which enables current to flow between the inner and

outer chambers when the detector is powered up. As

smoke enters the detector, particles become attached to

the ions, causing a reduction in current flow in the outer

chamber and hence an increase in voltage measured at

the junction between the two chambers. The voltage

increase is monitored by the electronic circuitry which

triggers the detector into the alarm state at a preset

threshold. An externally visible red LED lights up when

the detector changes to alarm state.

Ionisation smoke detectors are good general-purpose

detectors which respond well to fast-burning

(flaming) fires and are widely used for property

protection.

Integrating ionisation smoke detector

This type of detector works on the same principles as

the ionisation smoke detector, but has modified signal

processing circuitry which allows an alarm threshold to be

present for up to 20 seconds without initiating an alarm.

This type of detector is suitable for use in areas where

transient high levels of smoke may be expected.

Integrating effect in analogue addressable systems

In XP95 systems, the integrating effect can be mimicked

in both ionisation and optical smoke detectors by

adjusting the control equipment software to cause an

appropriate delay. Discovery smoke detectors should be

set to Mode Two or Mode Four to achieve this effect.

Optical (photo-electric) smoke detector

Optical smoke detectors incorporate a pulsing infra-red

LED located in a chamber within the housing of the

detector. The chamber is designed to exclude light from

any external source. At an angle to the LED is a photo-

diode which normally does not register the column of

light emitted by the LED. In the event of smoke from a

fire entering the chamber, the light pulse from the LED

will be scattered and hence registered by the photo-

diode. If the photo-diode ‘sees’ smoke on the two

following pulses, the detector changes into alarm state

and the indicator LED lights up. The detector housing

is identical to that of the ionisatio n detector but has

an indicator LED which is clear in quiescent state but

produces red light in alarm.

Optical smoke detectors respond particularly well to

slow-burning (smouldering) fires. They are widely

used for life protection.

5How do Detectors Work?

Heat detector

Most conventional heat detectors operate by using a

matched pair of thermistors to sense heat. One thermistor

is exposed to the ambient temperature, the other is

sealed. In normal conditions the two thermistors register

similar temperatures, but, on the development of a fire,

the temperature recorded by the exposed thermistor

will increase rapidly, resulting in an imbalance of the

thermistors, causing the detector to change into alarm

state. Rate-of-rise detectors are designed to detect a fire

as the temperature increases, but they also have a fixed

upper limit at which the detector will go into alarm if the

rate of temperature increase has been too slow to trigger

the detector earlier.

The Series 65 and AlarmSense CS (static response) heat

detectors have only one thermistor. They change to the

alarm state at a preset temperature.

Externally, the heat detectors are distinguishable from

the smoke detectors by having wide openings to the

surrounding atmosphere to allow good movement of air

around the external thermistor.

A heat detector may be more appropriate than a

smoke detector where the environment is dirty

or smoky under normal conditions. It must be

recognised, however, that any heat detector will

respond only when a fire is well established and

generating a high heat output.

Multisensor detector

A multisensor detector is basically an optical smoke

detector - so it will respond well to smouldering fires. The

addition of a heat sensing element allows the multisensor

to give a response to fast burning (flaming) fires which is

comparable to that of an ionisation detector.

Multisensor detectors are general purpose detectors

which respond well to a wide range of fires.

Carbon Monoxide (CO) detector

Carbon Monoxide (CO) is a poisonous gas produced by

combustion and a CO fire detector is used to indicate the

outbreak of a fire by sensing the level of CO in the air.

The detector has an electrochemical cell which senses CO,

but not smoke or other combustion products. The cells

do not require much power, so the detector can be made

electrically compatible with ordinary smoke and heat

detectors. Apollo manufacturers a CO detector as part of

the Discovery range.

CO detectors are particularly good at detecting deep-

seated, smouldering fires.

Beam detector

A beam detector is made up of three main parts: the

transmitter, which projects a beam of infra-red light;

the receiver which registers the light and produces an

electrical signal; and the interface, which processes the

signal and generates alarm or fault signals. When a fire

develops, smoke particles obstruct the beam of light and,

once a pre-set threshold has been exceeded, the detector

will go into alarm.

Beam detectors are designed to protect large

open spaces such as atria, museums, churches and

warehouses.

Flame detector

A flame detector is designed to detect either ultraviolet

(UV) or infra-red (IR) radiation emitted by a fire. The XP95

Dual IR flame detector is sensitive to low-frequency,

flickering infra-red radiation. This means that the detector

can operate even if the lens is contaminated by a layer of

oil, dust, water vapour or ice.

Flame detectors are effective in protecting areas

where flaming fires may be expected.

6 New Products

New Products

Apollo prides itself on being a leader in product

innovation. Providing fire solutions that meet the

demands of our customers is the main pillar of

Apollo’s product development programme. We

are constantly working with our customers to

develop new products to meet their needs.

A further commitment to Apollo’s customer focus

has seen the Marketing team be strengthened

by the introduction of three new product

management roles. These dedicated personnel

will be responsible for the future direction of the

portfolio as well as the internal management of

the ranges.

A prime responsibility of the new roles is

continuation of customer focused product

development within Apollo and continuing to be

the Partner of Choice.

If you have any comments or suggestions on

any new or existing products, feel free to email

[email protected]

7New Products

New products for 2009

Discovery Upgrade

The Discovery range has been subjected to a

thorough revision of the electronics and this

has resulted in significant improvement to the

Multisensor detector capabilities. It is possible

to read out virtually instantly the analogue

values for smoke and heat separately.

DIN-Rail Mains Input/Output Unit

The DIN-Rail Mains Input/Output Unit provides

a voltage-free, single pole change-over relay

output and a monitored switch input. The

unit supervises one or more normally-open

switches connected to a single pair of cables.

DIN-Rail Sounder Controller (5 Amperes)

The DIN-Rail Sounder Controller (5 Amperes)

is used to control the operation of a zone of

externally powered sounders and report their

status to the control panel.

Deckhead Mounting Box

The Deckhead Mounting Box gives extra

protection to devices to be fitted in areas

where there is the possibility of moisture or

condensation ingressing through the rear of

the of the base. This new version is suitable

for a wider range of detector bases as well

as Apollo’s AV bases.

2009 – Under development

There are a number of new products due for

launch during the course of 2009. They are at

the early stages of development. When ready

for launch the website, eMonitor and Monitor

newsletters will announce this, so keep an eye

out! Products currently under development, in

no particular order include:

XPander Input/Output Unit

Locally Powered Zone Monitor

DIN-Rail Zone Monitor for IS Heads

110dB(A) Open-Area Sounder Beacon

Marine 110dB(A) Open-Area Sounder Beacon

Discovery CO/Heat Detector

Sounder Controller 8 Amperes (Marine)

Conventional Flush Mounted Smoke Detector

Marine DIN-Rail Mains Input/Output Unit

Marine Base Mounted Flame Detectors

Discovery Open-Area Sounder Beacon

UL approved Open-Area Sounder

UL approved Releasing Control Module

UL approved Mini Monitor Module

108 Intelligent Fire Detection

Intelligent Fire Detection

InanIntelligentsystemalldeviceshaveunique‘addresses’andare

connectedinloopstothecontrolpanel.Intelligentsystemsgiveadvanced

warningofadevelopinghazardandcanpinpointtheindividualdevice

raisingalarm.Therearetwotypesofintelligentsystem–thosewith

‘distributedintelligence’andthosewith‘centralisedintelligence’.

Insystemswithdistributedintelligencethedetectorsincorporate

processorswhichcandeterminewhetheralarmlevelsofsmokeorheat

existandcaninitiateactionaccordingly.

Detectorsinsystemswithcentralisedintelligencemonitortheairaround

themforsmokeorheatandtransmitthedatatothecontrolpanelon

interrogation.Theprocessorinthepanelcomparesthevalueswithstored

valuesanddetermineswhetherapre-alarmoralarmshouldbesignalled.

Theadvantagesofdistributedintelligencearelocaladaptationto

environmentandreductionoftrafficonthesupplyanddatawires.The

advantageofcentralisedintelligenceistheabilitytoupgradeasystemvery

quicklyandeasilybyupgradingthecontrolpanel.

Intelligent Fire Detection

DISCOVERY

9

Discoveryisarangeofhigh-specification,

intelligentfiredetectorsdevelopedto

meettherequirementsofsophisticated

systemswhileprovidingengineerswith

anadditionaldimensioninfireprotection

capability.Discoveryhasa‘distributed

intelligencesystem’wheredecisionsare

madeinthedetectorheadaswellas

atthecontrolpanel.Driftcompensation

isalsoincorporatedintothedetector,

allowingittoadapttodirtyordusty

environments,whichreducesfalsealarms.

Each detector in the Discovery range can operate in one

of five response modes, which can be selected from the

control panel or hand held programmer. The response

characteristics have been carefully set so that the detectors

comply with the requirements of the relevant part of

EN54 in all response modes. Mode One will give a higher

sensitivity to fire than Mode Five.

Discovery gives you total reassurance in installations where

adaptability to changing conditions and protection against

unwanted alarms is paramount.

Key features of Discovery include:

• Rejection of transient signals

• Flashing LED option

• Five response modes for ease of optimisation to changing environments

• Drift compensation to ensure constant sensitivity

• Four bytes of non-volatile memory for user data

• Alarm flag for fast alarm reporting

• Conventional alarm facility during control panel processor fault

• 360° visibility in alarm

• Compatible with XP95 systems

• Insect Resistant

Discoveryintelligent fire

detection

NEW FOR 2009!The Discovery range has been subjected to a

thorough revision of the electronics and this has

resulted in significant improvement to the Multisensor

detector capabilities. It is possible to read out virtually

instantly the analogue values for smoke and heat

separately.

This enables panel manufacturers to develop features

which will provide more effective management

of false alarms. An example of this would be an

increased smoke value which might normally lead to

a pre-alarm or even an alarm. If the heat value is read

out separately and it shows little or no rise it can be

concluded that it is not smoke from a fire but steam

which is causing the high smoke analogue value.

DISCOVERY

10 Intelligent Fire Detection

Discovery Ionisation Smoke Detector The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Remote test feature

Discovery Optical Smoke Detector The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

• Remote test feature

Discovery Heat Detector The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector.

• Ideal in environments that are dirty or smoky under normal conditions

• Well suited for warehouses, loading bays and car parks

• Unaffected by wind or atmospheric pressure

• Remote test feature

Discovery Carbon Monoxide DetectorThe Discovery Carbon Monoxide (CO) Detector is good at detecting deep-seated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors.

• Enhanced detection capability

• Early response to hot fires

• Ideal for smouldering fires

• Less susceptible to false alarms caused by steam than smoke alarms

• Five response modes

• Remote test feature

Discovery Ionisation Smoke Detector 58000-500

Discovery Optical Smoke Detector 58000-600

Discovery Heat Detector 58000-400

Discovery Carbon Monoxide Detector 58000-300

Discovery Multisensor Detector The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. As a result, the multisensor is useful over a wide range of applications and is highly immune to false alarms.

• Ideal for a wide range of applications

• Enhanced false alarm management

• Well suited for environments such as hotel bedrooms

• Unaffected by wind or atmospheric pressure

• Well suited for sensitive environments

• Heat only, optical only options

• Remote test featureDiscovery Multisensor Detector 58000-700

Please check the Apollo website on a regular basis for up-to-date approvals information.

Intelligent Fire Detection

DISCOVERY

11

Intelligent Mounting Base All detectors in the Discovery range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

• XPERT addressing

• One way fit

• Locking feature to prevent unauthorised removal

Intelligent Deep BaseThe Intelligent Deep Base is a mounting base for Discovery products which has an increased depth which allows for cables to be inserted into the side of the product.

• Enables surface wiring

Isolating BaseThe new style Isolating Base senses and detects short-circuit faults on Discovery loops and spurs.

Product will replace 45681-321 during 2009

• The equivalent of up to 20 smoke detectors may be installed between isolating bases

• High brightness LED

• Compatible with Discovery CO detector

Intelligent Mounting Base 45681-210

Intelligent Deep Base 45681-209

Isolating Base 45681-284

IsolatorThe Isolator is placed at intervals on the loop and ensures that, in the case of a short-circuit, only the section between the isolators will be affected. When the short-circuit is removed, the isolators automatically restore power and data to the isolated section.

• Detectswiringshortcircuitsusingpatentedtechnology

• Minimisesdisruptionfromshort-circuits

• Automaticde-isolationonshort-circuitremoval

• The equivalent of up to 20 smoke detectors may be installed between isolators

Isolator 55000-720

Please check the Apollo website on a regular basis for up-to-date approvals information.

DISCOVERY

12 Intelligent Fire Detection

Isolator BaseThe Isolator Base is unique and designed to only accept the Isolator 55000-720.

• Onlyacceptsisolators

Isolator Base 45681-211

Intelligent Heater BaseThe Intelligent Heater Base is designed to be used in cold climates where environmental conditions could result in either icing or condensation affecting the operation of detectors. It is recommended that the heater base be used in conjunction with either a Waterproof Base Cover or Deckhead Mounting Box to minimise moisture ingress.

• Raisestheambienttemperatureofadetectorchamber by approximately 10°C

• Limitstheriskofpotentialforloseoffunctionality caused to detectors installed in these conditions.

Intelligent Heater Base 45681-219Waterproof Base Cover 45681-519Deckhead Mounting Box 45681-217

Intelligent Low Power Relay BaseThe Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.

• Givesasetofvoltagefreecontactscontrolledby the remote output of a detector

• Drawsnegligiblecurrent

• Capableofswitchingupto30Vat1A

Intelligent Low Power Relay Base 45681-242

MiniDisc Remote Indicator The MiniDisc Remote Indicator is a light-weight, compact LED indicator for use in fire protection systems.

• Can be used across the entire Apollo range

• Small and discrete

• Anti-tamper screw to protect against unauthorised removal

MiniDisc Remote Indicator 53832-070

Please check the Apollo website on a regular basis for up-to-date approvals information.

Intelligent Fire Detection

DISCOVERY

13

Product Name Part Number Page No.

MOUNTING ACCESSORIES 82

Backplate 45681-233 83

Base Cover 45681-380 83

Conduit Box 45681-204 83

Sounder Ceiling Plate 45681-311 83

Module Base 38531-822 83

Deckhead Mounting Box 45681-217 84

Metal Deckhead Mounting Box PG16 29600-131 84

Metal Deckhead Mounting Box M20 29600-139 84

Deckhead Adaptor PG16-M20 27249-005 84

Detector Ceiling Tile Mounting Box 45681-309 84

Sounder Ceiling Tile Mounting Box 45681-310 84

Beacon Enclosure 29600-318 84

DIN-Rail Interface Enclosure (4 units) 29600-239 85

DIN-Rail Interface Enclosure (10 units) 29600-240 85

1.5mm Hexagonal Driver 29600-095 85

MANUAL CALL POINTS 78

Discovery Manual Call Point Red (Surface) 58100-910 79

Discovery Manual Call Point with Isolator Red (Surface) 58100-908 79

Discovery Manual Call Point White 58100-926 79

Discovery Manual Call Point Yellow 58100-927 79

Discovery Manual Call Point Blue 58100-928 79

Discovery Manual Call Point Green 58100-929 79

Transparent Hinged Cover 26729-152 79

Weatherproof Manual Call Point Red 58100-950 80

Weatherproof Manual Call Point Red with Isolator 58100-951 80

STANDARD INTERFACES 69

Input/Output Unit 55000-847 70

Three Channel Input/Output Unit 55000-588 70

Three Channel Input/Output Unit PCB only 43781-588 70

Output Unit 55000-849 70

Sounder Control Unit 55000-852 70

Switch Monitor 55000-843 71

Switch Monitor Plus 55000-841 71

Zone Monitor 55000-845 71

MINI INTERFACES 73

Mini Switch Monitor 55000-760 74

Mini Switch Monitor with fly leads 55000-833 74

Mini Switch Monitor with fly leads (Interrupt) 55000-832 74

DIN-RAIL INTERFACES 75

NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76

DIN-Rail Input/Output Unit 55000-803 76

DIN-Rail Output Unit 55000-804 76

DIN-Rail Switch Monitor 55000-822 76

DIN-Rail Switch Monitor Plus 55000-821 77

DIN-Rail Zone Monitor with Isolator 55000-812 77

DIN-Rail Dual Isolator 55000-802 77

Ancillary devices available for the Discovery range:

DISCOVERY

14 Intelligent Fire Detection

Product Name Part Number Page No.

AUDIO VISUAL SIGNALLING

Discovery Sounder Beacon Base 45681-393 65

Intelligent Open-Area Sounder Red 55000-001 54

Intelligent Open-Area Sounder White 55000-002 54

Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54

Intelligent 100dB (A) Open-Area Sounder White 55000-279 54

Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54

Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54

Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54

Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54

Integrated Base Sounder 45681-278 56

Integrated Base Sounder with Isolator 45681-277 56

Integrated Base Sounder Slow Whoop 45681-291 56

Integrated Base Sounder Slow Whoop with Isolator 45681-290 56

Integrated Base Sounder DIN-Tone with Isolator 45681-300 56

White Cap 45681-292 56

Red Cap 45681-293 56

Intelligent Base Sounder 45681-265 56

Intelligent Base Sounder, for use with Isolating Base 45681-266 56

Intelligent Base Sounder Slow Whoop 45681-267 56

Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56

White Cap 29600-256 56

Red Cap 29600-257 56

Ancillary Base Sounder 45681-276 56

Intelligent Open-Area Beacon Red Lens 55000-009 59

Intelligent Open-Area Beacon Clear Lens 55000-010 59

Loop-Powered Beacon Red 55000-877 59

Loop-Powered Beacon Amber 55000-879 59

Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59

Beacon Enclosure 29600-318 59

Loop-Powered Beacon Base with Isolator 45681-333 61

Loop-Powered Beacon Base with Standard Flash 45681-335 61

Loop-Powered Beacon Base with Australian Flash 45681-337 61

Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63

Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63

Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63

Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63

Multi-Tone Open-Area Sounder Beacon Red 55000-291 63

Multi-Tone Open-Area Sounder Beacon White 55000-292 63

Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63

Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63

Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63

Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63

Sounder Beacon Base with Isolator 45681-330 65

Sounder Beacon Base 45681-331 65

Sounder Beacon Base with Australian Tone 45681-336 65

Sounder Beacon Base with Isolator DIN-Tone 45681-334 65

Sounder Beacon Base with NZ Tone 45681-338 65

Sounder Beacon Base Slow Whoop with Isolator 45681-332 65

Magnetic Wand 29650-001 67

Intelligent Fire Detection

DISCOVERY

15

XP95

16 Intelligent Fire Detection

TheXP95rangeofintelligentfire

detectorsisadvancedindesign,improved

inperformanceandhasuniquefeatures

thatbenefittheinstallerandenduser.

The range features smoke detectors (ionisation and optical),

standard and high temperature heat detectors and a

multisensor. Beam detectors, flame detectors, manual call

points, audio visual signalling devices, interface units and

isolators complete the range. XP95 has a ‘central intelligence’

system where all the decisions are made by the control panel.

Apollo has always used an open, digital protocol since 1986

and has ensured backward compatibility when developing new

products. An open protocol allows freedom of choice for the

fire system specifier, installer and end user. A system using

a digital protocol is also much less susceptible to corruption

than an analogue protocol and is therefore often preferred in a

system which is life critical.

Key features of XP95 include:

• AlarmFlagforfastalarmreporting

• AlarmAddressforfastlocationofalarm

• XPERTcardaddressing

• Electronics-freebase

• Easyinstallation

• Elegantdesign

• InsectResistant

XP95intelligent fire detection

Intelligent Fire Detection

XP95

17

XP95 Ionisation Smoke Detector The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Minimal effects from temperature, humidity, atmospheric pressure

• Well protected against electromagnetic interference over a wide frequency range

XP95 Optical Smoke Detector The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

XP95 Heat Detector The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C.

• Ideal in environments that are dirty or smoky under normal conditions

• Well suited for warehouses, loading bays and car parks

• Unaffected by wind or atmospheric pressure

XP95 Multisensor DetectorThe XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.

• Sensitive to a wide range of fires

• Well suited for environments such as hotel bedrooms

• Unaffected by wind or atmospheric pressure

XP95 Ionisation Smoke Detector 55000-500XP95 Ionisation Smoke Detector (Black) 55000-660XP95 Ionisation Smoke Detector (VdS) 55000-520

XP95 Optical Smoke Detector 55000-600XP95 Optical Smoke Detector (Black) 55000-660XP95 Optical Smoke Detector (VdS) 55000-620

XP95 Heat Detector A2S 55000-400XP95 Heat Detector A2S (VdS) 55000-420XP95 Heat Detector CS 55000-401

XP95 Multisensor Detector 55000-885

Please check the Apollo website on a regular basis for up-to-date approvals information.

XP95

18 Intelligent Fire Detection

Intelligent Mounting BaseAll detectors in the XP95 range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

• XPERT addressing

• One way fit of detector

• Locking feature to prevent unauthorised removal

Isolating BaseThe new style Isolating Base senses and detects short-circuit faults on XP95 loops and spurs.

• Theequivalentofupto20smokedetectorsmay be installed between isolating bases

• HighbrightnessLED

Intelligent Mounting Base 45681-210Intelligent Mounting Base (Black) 45681-361

Isolating Base 45681-284

IsolatorThe Isolator is placed at intervals on the loop and ensures that, in the case of a short-circuit, only the section between the isolators will be affected. When the short-circuit is removed, the isolators automatically restore power and data to the isolated section.

• Detectswiringshortcircuitsusingpatentedtechnology

• Minimisesdisruptionfromshort-circuits

• Automaticde-isolationonshort-circuitremoval

• Theequivalentofupto20smokedetectorsmay be installed between isolators

Isolator 55000-720

Isolator BaseThe Isolator Base is unique and designed to only accept the Isolator 55000-720.

• Onlyacceptsisolators

Isolator Base 45681-211

Product will replace 45681-321 during 2009

Please check the Apollo website on a regular basis for up-to-date approvals information.

Intelligent Fire Detection

XP95

19

Intelligent Heater BaseThe Intelligent Heater Base is designed to be used in cold climates where environmental conditions could result in either icing or condensation affecting the operation of detectors. It is recommended that the heater base be used in conjunction with either a Waterproof Base Cover or Deckhead Mounting Box to minimise moisture ingress.

• Raisestheambienttemperatureofadetectorchamber by approximately 10°C

• Limitstheriskofpotentialforlossoffunctionality caused to detectors installed in these conditions.

Intelligent Heater Base 45681-219Waterproof Base Cover 45681-519Deckhead Mounting Box 45681-217

MiniDisc Remote IndicatorThe MiniDisc Remote Indicator is a light-weight, compact LED indicator for use in fire protection systems.

• CanbeusedacrosstheentireApollorange

• Smallanddiscrete

• Anti-tamperscrewtoprotectagainstunauthorised removal

MiniDisc Remote Indicator 53832-070

Intelligent Deep BaseThe Intelligent Deep Base is a mounting base for XP95 products which has an increased depth which allows for cables to be inserted into the side of the product.

• Enablessurfacewiring

Intelligent Deep Base 45681-209

Intelligent Low Power Relay BaseThe Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.

• Givesasetofvoltagefreecontactscontrolledby the remote output of a detector

• Drawsnegligiblecurrent

• Capableofswitchingupto30Vat1A

Intelligent Low Power Relay Base 45681-242

Please check the Apollo website on a regular basis for up-to-date approvals information.

XP95

20 Intelligent Fire Detection

Ancillary devices available for the XP95 range:

Product Name Part Number Page No.

MOUNTING ACCESSORIES 82

Backplate 45681-233 85

Base Cover 45681-380 83

Conduit Box 45681-204 83

Sounder Ceiling Plate 45681-311 83

Module Base 38531-822 83

NEW!! Deckhead Mounting Box 45681-217 84

Metal Deckhead Mounting Box PG16 29600-131 84

Metal Deckhead Mounting Box M20 29600-139 84

Deckhead Adaptor PG16-M20 27249-005 84

Detector Ceiling Tile Mounting Box 45681-309 84

Sounder Ceiling Tile Mounting Box 45681-310 84

Beacon Enclosure 29600-318 84

DIN-Rail Interface Enclosure (4 units) 29600-239 85

DIN-Rail Interface Enclosure (10 units) 29600-240 85

Series 90 to XP95 Base Adaptor 45681-238 85

1.5mm Hexagonal Driver 29600-095 85

MANUAL CALL POINTS 78

XP95 Manual Call Point Red (Surface) 55100-905 79

XP95 Manual Call Point with Isolator Red (Surface) 55100-908 79

Transparent Hinged Cover 26729-152 79

STANDARD INTERFACES 69

Input/Output Unit 55000-847 70

Three Channel Input/Output Unit 55000-588 70

Three Channel Input/Output Unit PCB only 43781-588 70

Output Unit 55000-849 70

Sounder Control Unit 55000-852 70

Switch Monitor 55000-843 71

Switch Monitor Plus 55000-841 71

Zone Monitor 55000-845 71

MINI INTERFACES 73

Mini Switch Monitor 55000-760 74

Mini Switch Monitor with fly leads 55000-833 74

Mini Switch Monitor with fly leads (Interrupt) 55000-832 74

DIN-RAIL INTERFACES 75

NEW!! DIN-Rail Mains Input/Output Unit 55000-797 76

NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76

DIN-Rail Input/Output Unit 55000-803 76

DIN-Rail Output Unit 55000-804 76

DIN-Rail Switch Monitor 55000-822 76

DIN-Rail Switch Monitor Plus 55000-821 77

DIN-Rail Zone Monitor with Isolator 55000-812 77

DIN-Rail Dual Isolator 55000-802 77

AUDIO VISUAL SIGNALLING 52

Intelligent Open-Area Sounder Red 55000-001 54

Intelligent Open-Area Sounder White 55000-002 54

Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54

Intelligent 100dB (A) Open-Area Sounder White 55000-279 54

Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54

Intelligent Fire Detection

XP95

21

Product Name Part Number Page No.

Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54

Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54

Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54

Integrated Base Sounder 45681-278 56

Integrated Base Sounder with Isolator 45681-277 56

Integrated Base Sounder Slow Whoop 45681-291 56

Integrated Base Sounder Slow Whoop with Isolator 45681-290 56

Integrated Base Sounder DIN-Tone with Isolator 45681-300 56

White Cap 45681-292 56

Red Cap 45681-293 56

Intelligent Base Sounder 45681-265 56

Intelligent Base Sounder, for use with Isolating Base 45681-266 56

Intelligent Base Sounder Slow Whoop 45681-267 56

Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56

White Cap 29600-256 56

Red Cap 29600-257 56

Ancillary Base Sounder 45681-276 56

Intelligent Open-Area Beacon Red Lens 55000-009 59

Intelligent Open-Area Beacon Clear Lens 55000-010 59

Loop-Powered Beacon Red 55000-877 59

Loop-Powered Beacon Amber 55000-879 59

Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59

Beacon Enclosure 29600-318 59

Loop-Powered Beacon Base with Isolator 45681-333 61

Loop-Powered Beacon Base with Standard Flash 45681-335 61

Loop-Powered Beacon Base with Australian Flash 45681-337 61

Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63

Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63

Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63

Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63

Multi-Tone Open-Area Sounder Beacon Red 55000-291 63

Multi-Tone Open-Area Sounder Beacon White 55000-292 63

Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63

Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63

Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63

Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63

Sounder Beacon Base with Isolator 45681-330 65

Sounder Beacon Base 45681-331 65

Sounder Beacon Base with Australian Tone 45681-336 65

Sounder Beacon Base with Isolator DIN-Tone 45681-334 65

Sounder Beacon Base with NZ Tone 45681-338 65

Sounder Beacon Base Slow Whoop with Isolator 45681-332 65

XPERT CARDS

22 Intelligent Fire Detection

Apollo’sIntelligentrangesusepatented

XPERTcards.AuniqueXPERTcardprovides

simple,userfriendlyandaccurate

identificationofdetectorlocationwherea

codedcard,insertedintothebase,isread

byanydetectoroncepluggedin.Allthe

electroniccomponentsareinthedetector

butthelocationinformationisheldin

thebasewhichsavestimeandincreases

accuracyduringcommissioning.

XPERT cardsintelligent fire detection

Intelligent Fire Detection

XPERT CARDS

23

Blank XPERT CardA universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector.

• Simplifies and speeds up installation and commissioning

• Uses patented, proven technology

• Address remains the same, no matter how often detectors are replaced

• Flexibility to create any address

Pre-Addressed XPERT Cards Pre-addressed XPERT cards are supplied with pips already removed.

XPander XPERT cards are not interchangeable with those used with XP95 and Discovery.

• Saves time and increases accuracy during commissioning

• Uses patented, proven technology

• Address remains the same, no matter how often detectors are replaced

Blank XPERT Card 38531-771

Pre-Addressed XPERT Cards 1-126 45682-127

Product Name Part Number

XPander Blank XPERT Card (White) 29600-413

XPander Blank XPERT Card (Red) 29600-399

XPander XPERT Cards

Please check the Apollo website on a regular basis for up-to-date approvals information.

Conventional Fire Detection1024

Conventional Fire Detection

Inconventionalsystemsdetectorsarewiredas

acircuitor‘zone’.Theysignalfireconditionsto

acontrolpanelbychangingfromahightolow

impedance.Thepaneldetectsthisimpedance

changebycurrentmonitoringandidentifiesthe

zone.Individualdetectorscannotbeidentified.

ORBIS

Conventional Fire Detection 1125

Orbisisarangeofconventional

detectorswhichhasbeendeveloped

withsophisticatedtechnologypreviously

onlyfoundinintelligentdetectors.Orbis

isarangewithmodernstylingand

incorporatesamountingbasewhich

savesinstallationtime.

Key features of Orbis:

• AutomaticdriftcompensationwithDirtAlert® warning

• PatentedFasTest® which reduces the time taken to test

detectors

• SensAlert® uses a flashing LED to indicate that the

sensor is not operating correctly

• StartUp™forfastcommissioning

• Attractiveandcompactdesign

• ElectricallycompatiblewithSeries60andSeries65

• Widevoltageandoperatingtemperatureranges

• Algorithmsfortransientrejection

• FlashingLEDoption

• 360°visibilityofLEDs

• InsectResistant

Orbisconventional fire detection

ORBIS

Conventional Fire Detection1026

Orbis Optical Smoke DetectorThe Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms.

• Responds well to slow-burning, smouldering fires

• Performs well in black and white smoke

• Extra confirmation of smoke before alarm signal is given

• Reduced incidence of false alarms

• Sensing chamber keeps out dust and other airborne contaminants

• Operates over a broad range of voltages at extremes of temperature

Orbis Multisensor DetectorThe Orbis Multisensor detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone.

• Responds well to fast-burning, flaming fires

• Reduced incidence of false alarms

• Increased reliability of detection

• Sensing chamber keeps out dust and other airborne contaminants

• Operates over a broad range of voltages at extremes of temperature

Orbis Heat Detector The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions.

• Can be used for applications where smoke detectors are unsuitable

• Ideal in environments that are dirty or smoky under normal conditions

• Reduced incidence of false alarms

• Increased reliability of detection

Orbis Optical Smoke Detector ORB-OP-12001-APO

Orbis Optical Smoke Detector ORB-OP-12003-APOwith flashing LED †

Orbis Multisensor Detector ORB-OH-13001-APO

Orbis Multisensor Detector ORB-OH-13003-APOwith flashing LED †

Orbis Heat DetectorRate-of-Rise, MAT 50°CA1R - Standard ORB-HT-11001-APOA1R - with flashing LED † ORB-HT-11013-APO

Static, MAT 50°CA1S - Standard ORB-HT-11166-APOA1S with flashing LED † ORB-HT-11167-APOA2S - Standard ORB-HT-11002-APOA2S - with flashing LED † ORB-HT-11014-APO

Rate-of-Rise, MAT 65°CBR - Standard ORB-HT-11003-APOBR - with flashing LED † ORB-HT-11015-APO

Static, MAT 65°CBS - Standard ORB-HT-11004-APOBS - with flashing LED † ORB-HT-11016-APO

Rate-of-Rise, MAT 80°CCR - Standard ORB-HT-11005-APOCR - with flashing LED † ORB-HT-11017-APO

Static, MAT 80°CCS - Standard ORB-HT-11006-APOCS - with flashing LED † ORB-HT-11018-APO

MAT (Maximum Application Temperature)Choosing a heat detector

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

ORBIS

Conventional Fire Detection 1127

Orbis LX BaseThe Orbis LX Base is a low cost mounting base for use with Orbis detectors.

• Low cost option

TimeSaver Base® The TimeSaver Base® is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Detector locking mechanism

TimeSaver Diode BaseThe TimeSaver Diode Base has the same design as the standard TimeSaver Base® with the addition of a diode. It is used in systems which house active EOL monitoring for head removal.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

• Other devices continue to work during unauthorised removal of detectors

TimeSaver Relay BaseThe TimeSaver Relay Base incorporates a single-pole voltage-free change-over contact for switching external equipment. When the detector changes to the alarm state, the relay is energised, causing the contact to change state. The contact will remain in this condition until the detector is reset.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

• Capable of switching up to 30V at 1A

Orbis LX Base ORB-MB-00012-APO

TimeSaver Base® ORB-MB-00001-APO

TimeSaver Base® LX ORB-MB-00002-APO(simplified) version

TimeSaver Diode Base ORB-DB-00003-APO

TimeSaver Relay Base ORB-RB-10004-APO

Please check the Apollo website on a regular basis for up-to-date approvals information.

ORBIS

Conventional Fire Detection1028

Ancillary devices available for the Orbis range:

TimeSaver Deep BaseThe TimeSaver Deep Base is a mounting base for Orbis products which has an increased depth which allows for cables to be inserted into the side of the product.

• Enables surface wiring

MiniDisc Remote IndicatorThe MiniDisc Remote Indicator is a light-weight, compact LED indicator for use in fire protection systems.

• Can be used across the entire Apollo range

• Small and discrete

• Anti-tamper screw to protect against unauthorised removal

TimeSaver Deep Base ORB-MB-00019-APO

MiniDisc Remote Indicator 53832-070

Sav-Wire BaseThe Sav-Wire Base is designed to allow Orbis detectors to be used in ‘Sav-Wire’ detection and alarm systems.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Detector locking mechanism

• Can be used in ‘Sav-Wire’ systems

Sav-Wire Base ORB-SW-10005-APO

Orbis Heater BaseThe Orbis Heater base is designed to be used in cold climates where environmental conditions could result in either icing or condensation affecting the operation of detectors. It is recommended that the heater base be used in conjunction with either a Waterproof Base Cover or Deckhead Mounting Box to minimise moisture ingress.

• Raisestheambienttemperatureofadetectorchamber by approximately 10°C

• Limitstheriskofpotentialforlossoffunctionality caused to detectors installed in these conditions.

Orbis Heater Base ORB-HB-00020-APO

Waterproof Base Cover 45681-519

Deckhead Mounting Box 45681-217

Product Name Part Number Page No.

MOUNTING ACCESSORIES 82

Backplate 45681-233 85

Conduit Box 45681-204 83

Sounder Ceiling Plate 45681-311 83

Polycarbonate Deckhead Mounting Box 45681-217 84

Metal Deckhead Mounting Box PG16 29600-131 84

Metal Deckhead Mounting Box M20 29600-139 84

Deckhead Adaptor PG16-M20 27249-005 84

Detector Ceiling Tile Mounting Box 45681-309 84

Sounder Ceiling Tile Mounting Box 45681-310 84

1.5mm Hexagonal Driver 29600-095 85

Series 65 to Orbis Base Adaptor ORB-BA-10008-APO 85

Please check the Apollo website on a regular basis for up-to-date approvals information.

SERIES 65

Conventional Fire Detection 1129

Series65incorporateswell-proven

sensingtechnologiestogetherwith

advancesinmaterialsandelectronics.

Developedfromthehighlysuccessful

Series60rangeofdetectors,Series

65includesachip(integratedcircuit)

basedonthatusedinXP95analogue

addressabledetectors.

Having a wide operating voltage of 9-33V, the Series 65

detectors can be integrated into security systems, when used

with a relay base. The range consists of ionisation, integrating

ionisation and optical smoke detectors, four grades of heat

detector and a range of bases.

Each type of detector is available in three versions:

• Standard

• FlashingLED

• FlashingLEDandmagnetoperatedtestswitch

Key features of Series 65:

• Wideoperatingvoltage

• Advancedelectronictechnology

• FlashingLEDoption

• Magnetictestswitchoption

• Canbeusedonsecuritysystems

• ElectricallyandmechanicallycompatiblewithSeries60

• Provendetectionperformance

Series 65conventional fire

detection

SERIES 65

Conventional Fire Detection1030

Series 65 Ionisation Smoke DetectorThe Series 65 Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast burning, flaming fires

• Designed to operate in a variety of environments

• Wide operating voltage

• Flashing LED and magnet operated test switch option

Series 65 Integrating IonisationSmoke DetectorIonisation detectors use a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm. Circuitry in the integrating Ionisation Smoke Detector protects against transient levels of smoke above the normal threshold for up to 20 seconds.

• Responds well to fast burning, flaming fires

• Designed to operate in environments where transient levels of smoke may be expected

• Wide operating voltage

• Flashing LED and magnet operated test switch option

Series 65 Optical Smoke DetectorThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces red light in alarm.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

• Wide operating voltage

• Flashing LED and magnet operated test switch option

Series 65 Ionisation Smoke Detector 55000-217

Series 65 Ionisation Smoke Detector 55000-216with flashing LED †

Series 65 Ionisation Smoke Detector 55000-215with flashing LED and magnetic test switch †

Series 65 Ionisation Smoke Detector 55000-208(French)*

Series 65 Integrating Ionisation 55000-220Smoke Detector

Series 65 Integrating Ionisation 55000-219Smoke Detector with flashing LED †

Series 65 Integrating Ionisation 55000-218Smoke Detector with flashing LED and magnetic test switch †

Series 65 Optical Smoke Detector 55000-317

Series 65 Optical Smoke Detector 55000-316with flashing LED †

Series 65 Optical Smoke Detector with 55000-315flashing LED and magnetic test switch †

Series 65 Optical Smoke Detector 55000-308(French)*

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

* Does not have LPCB or VdS approval

SERIES 65

Conventional Fire Detection 1131

Series 65 Heat Detector The Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions.

• Can be used for applications where smoke detectors are unsuitable

• Ideal environments that are dirty or smoky under normal conditions

• Wide operating voltage

• Flashing LED and magnet operated test switch option

Series 65 Standard Base The Series 65 Standard Base has been designed to enable detectors to be fitted without the need of force – particularly useful when fitting to suspended ceilings. All Series 65 bases have a ‘one way only’ fit. They can be locked into place by a grub screw using a 1.5mm hexagonal screwdriver - part number 29600-095.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

• Contains no electrical parts

Series 65 Diode BaseThe Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the “L1 IN” and “L1 OUT” wiring terminals. This base can only be used with compatible control equipment.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

• Continues to work during unauthorised removal of detectors

Series 65 Heat DetectorRate-of-Rise, MAT 50°C, MSRT 65°CA1R - Standard 55000-122A1R - flashing LED † 55000-121A1R - flashing LED and magnetic test † 55000-120

Rate of Rise, MAT 65°C, MSRT 85°CBR - Standard 55000-127BR - flashing LED † 55000-126BR - flashing LED and magnetic test † 55000-125

Rate-of-Rise, MAT 80°C, MSRT 100°CCR - Standard 55000-132CR - flashing LED † 55000-131CR - flashing LED and magnetic test † 55000-130

Static, MAT 80°C, MSRT 100°CCS - Standard 55000-137CS - flashing LED † 55000-136CS - flashing LED and magnetic test † 55000-135

MAT (Maximum Application Temperature)MSRT (Maximum Static Response Temperature)

Series 65 Standard Base 45681-200

Series 65 Diode Base 45681-201

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

SERIES 65

Conventional Fire Detection1032

Series 65 Sav-Wire BaseThe Series 65 Sav-Wire Base is designed to allow Series 65 detectors to be used in ‘Sav-Wire’ detection and alarm systems.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

• Detects the removal of a detector head and reports a fault

Series 65 Standard Relay BaseThe Series 65 Standard Relay Base provides one set of volt-free, changeover (form C) contacts that change state when the detector signals an alarm.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

Series 65 Auxiliary Relay BaseThe Series 65 Auxiliary Relay Base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

Series 65 End-of-Line Relay BaseThe Series 65 End-of-Line (EOL) Relay Base is intended for use with 4-wire circuits and features two sets of changeover contacts and a power supervision relay.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

Series 65 12V Relay BaseThe Series 65 12V Relay Base is designed for use in both fire and security systems. For fire systems a jumper on the PCB is fitted to a ‘latching’ position. For security systems the jumper is moved to another position so that the base is non-latching.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains an earth connector

• Can be used in fire and security systems

Series 65 Sav-Wire Base 45681-206

Series 65 Standard Relay Base 45681-245

Series 65 Auxiliary Relay Base 45681-246

Series 65 12V Relay Base 45681-508

Series 65 End-of-Line Relay Base 12V 45681-247

Series 65 End-of-Line Relay Base 24V 45681-248

Please check the Apollo website on a regular basis for up-to-date approvals information.

SERIES 65

Conventional Fire Detection 1133

Ancillary devices available for the Series 65 range:

MiniDisc Remote IndicatorThe MiniDisc Remote Indicator is a light-weight, compact LED indicator for use in fire protection systems.

• Can be used across the entire Apollo range

• Small and discrete

• Anti-tamper screw to protect against unauthorised removal

MiniDisc Remote Indicator 53832-070

Product Name Part Number Page No.

MOUNTING ACCESSORIES 82

Backplate 45681-233 85

Series 65 Base Cover 45681-370 83

Conduit Box 45681-204 83

Module Base 38531-822 83

Metal Deckhead Mounting Box PG16 29600-131 84

Metal Deckhead Mounting Box M20 29600-139 84

Deckhead Adaptor PG16-M20 27249-005 84

Detector Ceiling Tile Mounting Box 45681-309 84

1.5mm Hexagonal Driver 29600-095 85

AUDIO VISUAL SIGNALLING 52

Series 65 Sounder Base 45681-512 57

Series 65 Sounder Base with diode 45681-513 57

Please check the Apollo website on a regular basis for up-to-date approvals information.

Two-Wire Technology1034

Two-Wire Technology

Inconventionalsystems,detectorsarehardwired

intoacircuitorzone.Theysignalafirecondition

toacontrolpanelbychangingfromahightolow

impedance.Thepaneldetectsthisimpedance

changebycurrentmonitoringandidentifiesthe

zone.Individualdetectorscannotbeidentified.In

two-wireconventionalsystems,firedetectionand

alarmproductsareconnectedtothesamepair

ofsupplywires,makinginstallationquicker,less

expensiveandmoreflexiblethantraditionalfour-

wiresystems.Two-wiresystemsareparticularly

wellsuitedforsmalltomediumsizedbuildings.

ALARMSENSE

Two-Wire Technology 1135

AlarmSensehasbeendevelopedto

makethedesignandinstallationofa

firedetectionandalarmsystemeasier

andmoreeconomicforsmalltomedium

sizedbuildings.Therangealsoallows

anexistingsystemtobeextendedor

modifiedifnecessary.Thisflexibility

makesAlarmSenseanexcellentchoice

foruseinHMOs.

The AlarmSense range incorporates a number of technologically

advanced features such as patented RemovAlert™ which

alerts the control panel if a detector has been removed

without authorisation.

The entire AlarmSense range has been designed to enable

compliance with BS5839-1 and BS5839-6 in addition to EN54

standards. AlarmSense is also compliant with the Construction

Products Directive (CPD).

Key features of AlarmSense include:

• PatentedRemovAlert™headremovalmonitoring

• Localandgeneralalarmswitching

• Reducedwiringcosts

• Quickandsimpleinstallation

• Falsealarmreductionwith‘non-priority’signalling

• Flexiblesystemdesign

• Failsafeoperationofmanualcallpoints

• Detectorsandcallpointalarmsidentifiableseparately

AlarmSensetwo-wire

technology

ALARMSENSE

Two-Wire Technology1036

AlarmSense Base AlarmSense detectors can only be mounted into the AlarmSense Base. The base is used for installing detectors that do not require an integral sounder or sounder beacon.

• Detects the removal of a detector head and reports a fault

• Continues to work during unauthorised removal of detectors

• Quick and simple installation

AlarmSense Optical Smoke DetectorThe AlarmSense Optical Smoke Detector works using the light scatter principle. The detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• 360° visibility of LEDs

• Reduces false alarms

• Quick and simple installation

AlarmSense Integrating Optical Smoke Detector The AlarmSense Integrating Optical Smoke Detector works using the light scatter principle. The detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber. The detector also has the ability to monitor and discard transient sources of smoke.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• 360° visibility of LEDs

• Quick and simple installation

• Designed to operate in environments where transient levels of smoke may be expected

• Reduces false alarms

• Can be used for applications where smoke detectors are unsuitable

• Ideal environments that are dirty or smoky under normal conditions

• CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms

• Reduction of false alarms

• 360° visibility of LEDs

• Quick and simple installation

AlarmSense Heat DetectorThere are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature.

AlarmSense Optical Smoke Detector 55000-390

AlarmSense Integrating 55000-391Optical Smoke Detector

AlarmSense Heat Detector A1R 55000-190

AlarmSense Heat Detector CS 55000-193

AlarmSense Base 45681-244

Please check the Apollo website on a regular basis for up-to-date approvals information.

ALARMSENSE

Two-Wire Technology 1137

AlarmSense Alarm RelayThe AlarmSense Alarm Relay enables devices such as beacons, pillow/bed alarms and radio vibrating or paging devices to be connected to the fire detection system. This allows the system to comply with the requirements of the DDA.

• Ensures DDA compliance

MiniDisc Remote IndicatorThe MiniDisc Remote Indicator is a light-weight, compact LED indicator for use in fire protection systems.

• Can be used across the entire Apollo range

• Small and discrete

• Anti-tamper screw to protect against unauthorised removal

AlarmSense Alarm Relay 55000-835

MiniDisc Remote indicator 53832-070

AlarmSense Manual Call PointThe AlarmSense Manual Call Point is compliant with EN54:11. It is different from other conventional call points in that it can be detected as an operated call point rather than a detector that has changed to the alarm state.

• Gives immediate response

• Unique identification signalling

• Resettable element

AlarmSense Manual Call Point 55100-894(Surface)

AlarmSense Sounder Base The AlarmSense Sounder Base can only be used with AlarmSense detectors. It is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and red or white caps are available for stand-alone installation

• Detects the removal of a detector head and reports a fault

• Continues to work during unauthorised removal of detectors

• Quick and simple installation

• Provides audible signal and detection at one point

• High and low volume ranges

AlarmSense Sounder Base LR 45681-341

AlarmSense Sounder Base 45681-510

Red Cap 45681-295

White Cap 45681-294

AlarmSense Sounder Beacon Base The AlarmSense Sounder Beacon Base is designed to be used with AlarmSense detectors only.

• Sounder range between 70dB(A) and 87dB(A)

• Detects the removal of a detector head and reports a fault

• Continues to work during unauthorised removal of detectors

• Quick and simple installation

AlarmSense Sounder Beacon Base LR 45681-340

AlarmSense Sounder Beacon Base 45681-509

Red Cap 45681-295

White Cap 45681-294

Please check the Apollo website on a regular basis for up-to-date approvals information.

ALARMSENSE

Two-Wire Technology1038

Ancillary devices available for the AlarmSense range:

Product Name Part Number Page No.

MOUNTING ACCESSORIES 82

Backplate 45681-233 83

Conduit Box 45681-204 83

Sounder Ceiling Plate 45681-311 83

Module Base 38531-822 83

Metal Deckhead Mounting Box PG16 29600-131 84

Metal Deckhead Mounting Box M20 29600-139 84

Deckhead Adaptor PG16 - M20 27249-005 84

Detector Ceiling Tile Mounting Box 45681-309 84

Sounder Ceiling Tile Mounting Box 45681-310 84

1.5mm Hexagonal Driver 29600-095 85

MANUAL CALL POINTS 78

AlarmSense Manual Call Point (Surface) 55100-894 80

AlarmSense Manual Call Point (Flush) 55100-893 80

AUDIO VISUAL SIGNALLING 52

AlarmSense Sounder Base LR 45681-341 57

AlarmSense Sounder Base 45681-510 57

AlarmSense Sounder Beacon Base LR 45681-340 65

AlarmSense Sounder Beacon Base 45681-509 65

White Cap 45681-294 65

Red Cap 45681-295 65

Apollo makes ordering AlarmSense products for a project easy with a selection of detector/sounder base or detector/sounder beacon base packages. See pages 57 and 65 for a description of the AlarmSense Sounder Base and Sounder Beacon Base.

Sounder Base Combination Part Number

With Optical Smoke Detector 55000-392

With Integrating Optical Smoke Detector 55000-393

With A1R Heat Detector 55000-196

With CS Heat Detector 55000-197

Sounder Beacon Base Combination Part Number

With Optical Smoke Detector 55000-394

With Integrating Optical Smoke Detector 55000-395

With A1R Heat Detector 55000-198

With CS Heat Detector 55000-199

ALARMSENSE

Two-Wire Technology 1139

Wireless Technology1040

Wireless Technology

Traditionally,firedetectionsystemsinindustrial

andcommercialapplicationshaveusedhardwired

installations.Thesesystemsaregenerallyinstalled

atthetimeofconstructionorrefurbishment,

makingthelayingofcableslessofanissue.Certain

applicationsdonotlendthemselvestothisapproach,

suchasoccupiedbuildings,heritagesites,palaces,

annexesetc.-thisiswherewirelesssystems

providetheidealsolution.

Wireless Technology 1141

XPanderwireless technology

XPANDER

XPanderisasysteminwhichindividual

detectors,callpointsandalarmdevices

communicatewiththeXP95loopby

radiosignals.Aninterfaceisconnected

totheloopinthesamewayasanyother

interface,suchasaninput/outputunit.

Every XPander device is assigned an address and this

address is recognised by the control panel in the same

way as the address of any other device connected directly

to the loop wiring. The XPander range benefits from the

patented XPERT technology that is also used in Discovery

and XP95. See page 23 for more details.

XPander can be incorporated into fire detection systems in

stately homes and architecturally sensitive buildings where

the use of fire cables is either impractical or undesirable.

Key features of XPander include:

• Easytoinstall

• XPERTcardaddressing

• Self-monitoring

• Proventechnology

• Nospecialcontrolpanelneeded

• 868MHzradiochannels

• Upto15devicesperinterface

• Upto5interfacesperloop

All detectors within the XPander range are sold with

mounting bases.

Please ensure that you have attended an approved XPander

training course prior to purchasing products from the

XPander range.

A site survey tool must be included in the first order of

XPander products as a site survey must be carried out prior

to installation.

Wireless Technology1042

XPander Optical Smoke Detector and Mounting BaseThe XPander Optical Smoke Detector works on the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Modified to function with the low current requirements of radio systems

• Bi-directional (monitored) radio platform

• Easy to install

• Powered by two independent packs of 3 AA alkaline batteries with a typical three year life

XPANDER

XPander Multisensor Detector and Mounting BaseThe XPander Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.

• Sensitive to a wide range of fires

• Well suited for environments such as hotel bedrooms

• Modified to function with the low current requirements of radio systems

• Bi-directional (monitored) radio platform

• Easy to install

• Powered by two independent packs of 3 AA alkaline batteries with a typical three year life

XPander Heat Detector and Mounting BaseThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector (CS) which responds only when a fixed temperature has been reached and a rate-of-rise detector (A1R) which has a fixed upper limit, but in addition, measures the rate of increase in temperature.

• Can be used in applications where smoke detectors are unsuitable

• Ideal environments that are dirty or smoky under normal conditions

• CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms

• Modified to function with the low current requirements of radio systems

• Bi-directional (monitored) radio platform

• Easy to install

• Powered by two independent packs of 3 AA alkaline batteries with a typical three year life

XPander Optical Smoke Detector and Mounting Base XPA-CB-12034-APO

XPander Multisensor Detector and Mounting Base XPA-CB-13032-APO

XPander Heat Detector and Mounting Base

Rate-of-Rise (A1R) XPA-CB-11170-APO

Static (CS) XPA-CB-11171-APO

Please check the Apollo website on a regular basis for up-to-date approvals information.

Wireless Technology 1143

XPANDER

Ancillary devices available for the XPander range:

XPander Survey ToolThe XPander Survey Tool is used at the site survey stage to ascertain if a site is suitable for an XPander installation. A site survey must be carried out before XPander can be installed.

• Testsforradiosignalstrength

XPander Survey Tool XPA-TE-14010-APO

There are two aerials available to complement the XPander range:• XPanderExternalAerial(XPA-AE-14008-APO) which is used to strengthen the radio signals

sent between the XPander Interface Unit and XPander devices.

• XPanderExternalDirectionalAerial(XPA-AE-14009-APO) which is used to pick up radio signals from outbuildings and annexes.

XPander Loop InterfaceThe XPander Loop Interface communicates between the Intelligent control panel and the XPander detectors as the detectors alone can’t communicate directly with the panel.

• Connectsupto15XPanderdevicestoa XP95 loop

• TranslatesradiosignalsfromXPanderdetectors to the control panel

• Incorporatesanintegralloopisolatorandispolarity sensitive

XPander Interface Unit XPA-IN-14007-APO

XPander Sounder and Sounder Base RedXPA-CB-14001-APO

XPander Red Sounder Beaconand Red Sounder Base XPA-CB-14003-APO

XPander Manual Call Point

XPA-MC-14006-APO

Product Name Part Number Page No.

XPander Manual Call Point XPA-MC-14006-APO 80

XPander Sounder and Sounder Base Red XPA-CB-14001-APO 54

XPander Sounder and Sounder Base White XPA-CB-14002-APO 54

XPander Red Sounder Beacon and Red Sounder Base XPA-CB-14003-APO 63

XPander Amber Sounder Beacon and White Sounder Base XPA-CB-14004-APO 63

XPander Clear Sounder Beacon and White Sounder Base XPA-CB-14005-APO 63

XPander Blank XPERT Card (White) 29600-413

XPander Blank XPERT Card (Red) 29600-399

XPander XPERT cards are not interchangeable with those used with Discovery and XP95.

Please check the Apollo website on a regular basis for up-to-date approvals information.

Specialist Detectors44

Specialist Detectors

Inadditiontostandarddetectors,Apollooffera

rangeofspecialistdetectorssuitableforawide

varietyofapplications.

Specialist Detectors 45

FLAME DETECTORS

Flame Detectorsspecialist detectors

Flamedetectorsareeffectivein

protectingareaswhereflamingfires

maybeexpected.

Thereisachoiceofdetection

techniques-UltraVioletandInfra-red,

oracombinationofboth.

UVFlameDetectorsaregenerally

usedinenginerooms,factoriesand

warehouseapplications.

Infra-redFlameDetectorsareableto

toleratedirtierenvironmentswhich

mayblockUVradiationandare

generallyusedinapplicationssuchas

wastehandling,colourprintingand

papermanufacturing.

Specialist Detectors46

Flame Detector BracketThe Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors

• Allows flame detector to be moved to desired position

Flame Detector Weather ShieldThe Flame Detector Weather Shield protects the device from inclement conditions.

• Protects against water ingress

• Protects sensor from direct sunlight

Intelligent Dual IR Flame Detector The Intelligent Dual Infra-Red (IR²) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling and paper manufacturing plants and woodworking environments.

• Sensitive to flickering IR radiation

• Detects through films of oil, dust, water and ice

• Responds to flickering flames, including those invisible to the naked eye

• Compatible with Discovery and XP95 protocols

• Remote optical self-test function

• 90° field of view

• Up to 40m coverage

FLAME DETECTORS

Intelligent Triple IR Flame Detector The Intelligent Triple IR Flame Detector (IR³) is designed to protect areas where open flaming fires may be expected. It is sensitive to low-frequency, flickering infra-red radiation emitted by flames during combustion.

• Loop-powered

• Sensitive to flickering IR radiation

• Detects through films of oil, dust, water and ice

• Responds to flickering flames, including those invisible to the naked eye

• False alarms due to lighting or flickering sunlight are minimised

• Compatible with Discovery and XP95 protocols

Intelligent IR² Flame Detector 55000-280

Intelligent Flameproof IR² 55000-295Flame Detector

Intelligent IR³ Flame Detector 55000-020

Intelligent Flameproof IR³ Flame 55000-021Detector

Flame Detector Bracket 29600-203

Flame Detector Weather Shield 29600-206

Please check the Apollo website on a regular basis for up-to-date approvals information.

Specialist Detectors 47

FLAME DETECTORS

47

Intelligent Base Mounted UV Flame Detector The Intelligent Base Mounted UV Flame Detector is designed to protect internal areas where open fires may be expected. The detector has a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation.

• Responds to stationary flames with no flicker

• Sensitive to UV radiation emitted by flames during combustion

• Compact flame detector which can fit into Discovery or XP95 bases

• Loop-powered

Ancillary products:

Intelligent Base Mounted UV Flame 55000-022Detector

Base Mounted Flame Detector Bracket 29600-458

Intelligent Base Mounted IR³ Flame Detector The Intelligent Base Mounted IR³ Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation.

• Responds to stationary flames with no flicker

• Sensitive to low-frequency flickering IR radiation emitted by flames during combustion.

• Compact flame detector which can fit into Discovery or XP95 bases

• Loop-powered

• False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques.

Intelligent Base Mounted IR³ 55000-024Flame Detector

Base Mounted Flame Detector Bracket 29600-458

Intelligent Base Mounted UV IR² Flame Detector The Intelligent Base Mounted UV IR² Flame Detector is designed to protect areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation.

• Responds to stationary flames with no flicker

• Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion

• Compact flame detector which can fit into Discovery or XP95 bases

• Loop-powered

• False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised

Intelligent Base Mounted UV IR² 55000-023Flame Detector

Base Mounted Flame Detector Bracket 29600-458

Product Name Part Number Page No.

Flame Sensor Test Unit and Case 29600-226 117

Please check the Apollo website on a regular basis for up-to-date approvals information.

Specialist Detectors48

BEAM DETECTORS

Beamdetectorsaredesignedto

protectlargeopenspacessuchasatria,

museums,churchesandwarehouses.

Beam Detectorsspecialist detectors

Specialist Detectors 49

BEAM DETECTORS

Intelligent Reflective Beam DetectorThe Intelligent Reflective Beam Detector differs from a traditional beam detector in that it is a single unit which houses a transmitter, a receiver and the control electronics. The beam detector is available in two versions: a single reflector model for distances of 5-50m and a four-reflector unit for distances of 50-100m.

• Loop-powered

• Compatible with Discovery and XP95 protocols

• Incorporates a short-circuit isolator

• Automatic drift compensation

• Automatic reset following alarm or fault condition

Reflective Beam Detector BackboxThe Reflective Beam Detector Backbox allows easy first fixing of the cabling and terminations to the Intelligent Reflective Beam Detector (55000-268 & 58000-273). The backbox can be surface or flush mounted.

• Aesthetically pleasing

Reflective Beam Detector Backbox 29600-241

Optical Beam DetectorThe conventional beam detector is made up of three parts: the transmitter, which projects a beam of infra-red light, the receiver, which registers the light and produces an electric signal, and the interface, which processes the signal and generates alarm or fault signals.

• Three selectable sensitivity levels

• Drift compensation

• Remote low interface

• Simple wiring and alignment

• Use XP95 Switch Monitor (55000-843) to interface it to an addressable loop.

Optical Beam Detector 29600-242

Intelligent Reflective Beam 55000-268Detector 5-50m

Intelligent Reflective Beam 55000-273Detector 50-100m

Firebeam®

Firebeam is a reflective beam smoke detector which is designed to protect large open spaces. It incorporates a motorised head that can align itself during commissioning.

• Continually corrects itself against building movement

• Controlled and adjusted from ground level

Firebeam Reflective Beam 29600-350Detector 5-40m

Firebeam Extension Kit 40-80m 29600-351

Firebeam Extension Kit 80-100m 29600-352

Firebeam Adaptor Plate 29600-353

Please check the Apollo website on a regular basis for up-to-date approvals information.

Firebeam® is a registered trade mark of The Fire Beam Company

Specialist Detectors50

DUCT DETECTORS

Duct Detectorsspecialist detectors

Specialist Detectors 51

DUCT DETECTORS

Intelligent Duct Smoke DetectorThe Intelligent Duct Smoke Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts in commercial and industrial premises. Its purpose is to prevent the re-circulation of smoke from an area on fire to areas unaffected by the fire.

• Operates in air speeds of 0.5m/s to 20m/s

• Transparent cover to view detector head LED

• Integral smoke test port

Orbis Duct DetectorThe Orbis Duct Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts.

• Designed to accept an Orbis detector head

• Used as supplementary detection

Intelligent Duct Smoke Detector 53546-022

Conventional Duct Smoke DetectorThe Conventional Duct Smoke Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts in commercial and industrial premises. Its purpose is to prevent the re-circulation of smoke from an area on fire to areas unaffected by the fire.

• For S65 and S60 ranges

• Operates in air speeds of 0.5m/s to 20m/s

• Transparent cover to view detector head LED

• Integral smoke test port

Conventional Duct Smoke Detector 53546-021

Orbis Duct Detector 53546-023

Extension Tubes

Product Name Part Number

300-750mm 53541-170

750-1500mm 53541-171

1500-3000mm 53541-172

Please check the Apollo website on a regular basis for up-to-date approvals information.

Audio Visual Signalling1052

Audio Visual Signalling

ApolloofferawiderangeofAudioVisual(AV)

signallingdevices–sounders,beacons,sounder

beaconsandsounderbeaconbasesforusein

conjunctionwiththeirrangeofconventionaland

intelligentdetectorstomeettherequirementsof

theDDA.

Audio Visual Signalling 53

Soundersaudio visual signalling

SOUNDERS

Audio Visual Signalling54

Intelligent Open-Area Sounder The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system.

• Self-test fault monitoring

• Choice of tones

• Group addressing and synchronisation of alarm

• Weatherproof IP65

• Comes with Isolating Base as standard

• Loop powered

• Output is 100 dB(A) at 90º

• Ceiling Mounted

Intelligent 100dB(A) Open-Area SounderThe 100dB(A) Loop-Powered Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system.

• Output is 100dB(A) at 90°

• Current consumption of 5.0mA

• Can be synchronised

• Group address facility

• Loop powered

• Wall mounted

Intelligent Weatherproof 100dB(A) Open-Area SounderThe 100dB(A) Weatherproof Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. The sounder comprises a backbox and sounder unit supplied together.

• IP 66 (immune to the affects of wind and precipitation)

• Output is 100dB(A) at 90°

• Current consumption of 5.0mA

• Can be synchronised

• Group address facility

• Loop powered

• Wall mounted

XPander Sounder and Sounder Base The XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points only.

• Wall mounted

• Wireless

• Eliminates cable problems

• Output is between 92 and 106db(A) at 1m - dependent on tone setting

Intelligent Open-Area Sounder 55000-001Red

Intelligent Open-Area Sounder 55000-002White

Intelligent 100dB(A) Open-Area 55000-278Sounder Red

Intelligent 100dB(A) Open-Area 55000-279Sounder White

Intelligent 100dB(A) Open-Area 55000-276Sounder Slow Whoop Red

Intelligent 100dB(A) Open-Area 55000-277Sounder Slow Whoop White

100dB(A) Weatherproof Sounder 55000-274Red

100dB(A) Weatherproof Sounder 55000-275White

XPander Sounder and XPA-CB-14001-APO

Sounder Base Red

XPander Sounder and XPA-CB-14002-APOSounder Base White

SOUNDERS

Please check the Apollo website on a regular basis for up-to-date approvals information.

Audio Visual Signalling 55

Base Sounders

audio visual signalling

BASE SOUNDERS

Audio Visual Signalling56

Integrated Base Sounder The Integrated Base Sounder comprises a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for use in enclosed areas.

• Two tone ranges

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Individual and group addressing

• Unique acoustic self-test

• Integrated base

• Isolator option

BASE SOUNDERS

Intelligent Base Sounder The Intelligent Base Sounder is for use with Discovery or XP95 ranges. It is a loop-powered sounder used to signal a fire alarm in enclosed areas. A Discovery or XP95 Mounting Base must be fitted to the Base Sounder, if a detector is to be fitted.

• Synchronisation of continuous and pulsed tones

• Multiple address allocation via master/slave configuration

• Loop powered

• Choice of two output levels

Ancillary Base SounderThe Ancillary Base Sounder is a local-area sounder designed for indoor use. It can be connected only to detection systems using Discovery or XP95 detectors and control panels with appropriate software.

• Guaranteed sound output of 85dB(A) at 1 metre

• Current consumption of only 3mA

• Loop powered

• Responds to signals from the associated detector - does not have an address of its own

• Adjustable volume control

Integrated Base Sounder † 45681-278

Integrated Base Sounder 45681-277with Isolator †

Integrated Base Sounder 45681-291Slow Whoop †

Integrated Base Sounder 45681-290Slow Whoop with Isolator †

Integrated Base Sounder 45681-300DIN-Tone with Isolator

Red Cap* 45681-293

White Cap* 45681-292

Intelligent Base Sounder 45681-265

Intelligent Base Sounder, for use 45681-266with Isolating Base

Intelligent Base Sounder 45681-267Slow Whoop

Intelligent Base Sounder Slow 45681-268Whoop, for use with Isolating Base

Red Cap* 29600-257

White Cap* 29600-256

Ancillary Base Sounder 45681-276

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

* Does not have CPD or VdS approval

Audio Visual Signalling 57

BASE SOUNDERS

AlarmSense Sounder Base The AlarmSense Sounder Base can only be used with AlarmSense detectors. It is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and red or white caps are available for stand-alone installation

• Detects the removal of a detector head and reports a fault

• Continues to work during unauthorised removal of detectors

• Quick and simple installation

• Provides audible signal and detection at one point

• High and low volume ranges

Series 65 Sounder Base The Series 65 Sounder Base is a high-efficiency conventional alarm sounder incorporating a base for the Series 65 range of detectors. It is designed so that separate detector and sounder circuits can be connected. The sounder base can be secured to a conduit box or surface mounted.

• 32 tones as standard

• Provides detection and alarm signal at one point

• Diode option

Series 65 Sounder Base 45681-512

Series 65 Sounder Base with diode 45681-513

AlarmSense Sounder Base LR 45681-341

AlarmSense Sounder Base 45681-510

Red Cap 45681-295

White Cap 45681-294

Please check the Apollo website on a regular basis for up-to-date approvals information.

Audio Visual Signalling58

Beaconsaudio visual signalling

BEACONS

Audio Visual Signalling 59

Intelligent Open-Area Beacon The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk that sounders will not be heard. It is weatherproof and can be used outside.

• Self-test fault monitoring

• Weatherproof IP65

• Group addressing

• Synchronisation of alarm

• Comes with Isolating Base as standard

• Loop powered

Loop-Powered Beacon The Loop-Powered Beacon is a local-area beacon designed for indoor use. The beacon has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard.

• High intensity LEDs

• More reliable than xenon beacons

• Automatic LED check

• Lockable

• Wide angle of visibility

• Enables DDA compliance

• Synchronised flash

• Can be used with Discovery or XP95

Beacon Enclosure The Beacon Enclosure is weatherproof and allows Apollo’s loop-powered beacon to be used in high-moisture environments such as swimming pools and food processing areas where wash-down occurs. The enclosure is supplied with a mounting bracket to accept a Discovery or XP95 base.

• Protects against water ingress

• Allows beacon to be used outdoors

• Accepts MiniDisc Remote Indicator

• IP67

Intelligent Open-Area Beacon 55000-009Red Lens

Intelligent Open-Area Beacon 55000-010Clear Lens

Loop-Powered Beacon Red 55000-877

Loop Powered Beacon Amber 55000-879

Loop Powered Beacon Clear Lens/Red Flash 55000-878

Beacon Enclosure 29600-318

BEACONS

Please check the Apollo website on a regular basis for up-to-date approvals information.

Audio Visual Signalling60

Beacon Basesaudio visual signalling

BEACON BASES

Audio Visual Signalling 61

Loop-Powered Beacon BaseThe Beacon Base is a loop-powered beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The beacon base can be used with either a detector fitted or with a cap as a stand-alone alarm device.

• Beacon flash rate of once per second

• Synchronisation of beacon flash

• Individual and group addressing

• Unique beacon self-test

• Loop powered

• Isolator option

Loop-Powered Beacon Base 45681-333with Isolator

Loop-Powered Beacon Base 45681-335with Standard Flash

Loop-Powered Beacon Base 45681-337with Australian Flash

White Cap 45681-292

Red Cap 45681-293

BEACON BASES

Please check the Apollo website on a regular basis for up-to-date approvals information.

Audio Visual Signalling62

Sounder Beaconsaudio visual signalling

SOUNDER BEACONS

Audio Visual Signalling 63

Intelligent Open-Area Sounder BeaconThe Intelligent Open-Area Sounder Beacon is designed for use in open areas and can be connected to an Apollo intelligent system.

• IP65 weatherproof

• Gives two functions at one point

• Self-test fault monitoring

• Choice of tones

• Group addressing and synchronisation of alarm

• Comes with Isolating Base as standard

• Loop powered

Multi-Tone Open-Area Sounder BeaconThe Multi-Tone Open-Area Sounder Beacon is designed for use in indoor open areas and can be connected to any Discovery or XP95 system. The sounder beacon complements Apollo’s intelligent and integrated base sounders as well as the loop powered 100dB(A) sounder.

• Powerful LED combined with 100dB(A) sound output

• Two volume settings

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Individual and group addressing

• Three tone choices

• Enables DDA compliance

• Isolator option

Intelligent Open-Area Sounder 55000-005Beacon Red Lens

Intelligent Open-Area Sounder 55000-006Beacon Clear Lens

Multi-Tone Open Area Sounder 55000-293Beacon Red with Isolator †

Multi-Tone Open Area Sounder 55000-294Beacon White with Isolator †

Multi-Tone Open Area Sounder 55000-291Beacon Red

Multi-Tone Open Area Sounder 55000-292Beacon White †

SOUNDER BEACONS

Weatherproof Multi-Tone Open Area Sounder Beacon The Weatherproof Multi-Tone Open Area Sounder Beacon is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder beacon complements Apollo’s intelligent and integrated base sounders as well as the loop powered 100dB(A) sounder.

• IP66 (immune to the affects of wind and precipitation)

• Powerful LEDs combined with 100dB(A) sound output

• Two volume settings

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Individual and group addressing

• Three tone choices

• Enables DDA compliance

• Isolator option

Weatherproof Multi-Tone Open Area 55000-298Sounder Beacon Red with Isolator

Weatherproof Multi-Tone Open Area 55000-299Sounder Beacon White with Isolator

Weatherproof Multi-Tone Open Area 55000-296Sounder Beacon Red

Weatherproof Multi-Tone Open Area 55000-297Sounder Beacon White

XPander Sounder Beacon and Sounder Base The XPander Sounder Beacon and Sounder Base is wireless and designed to be used with XPander detectors and manual call points only.

• Wireless

• Eliminates cable problems

• Enables DDA compliance

XPander Red Sounder XPA-CB-14003-APOBeacon and Red Sounder Base

XPander Amber Sounder XPA-CB-14004-APOBeacon and White Sounder Base

XPander Clear Sounder XPA-CB-14005-APOBeacon and White Sounder Base

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have CPD approval

Audio Visual Signalling64

Sounder Beacon Basesaudio visual signalling

SOUNDER BEACON BASES

Audio Visual Signalling 65

Sounder Beacon BaseThe Sounder Beacon Base is a loop-powered sounder and beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The Sounder Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device.

• Two volume ranges 55-75dB(A) and 75-91dB(A)

• Beacon flash rate of once per second

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Synchronisation of beacon flash

• Individual and group addressing

• Unique acoustic and beacon self test

• Enables DDA compliance

AlarmSense Sounder Beacon Base The AlarmSense Sounder Beacon Base is designed to be used with AlarmSense detectors only.

• Sounder range between 70dB(A) and 87dB(A)

• Detects the removal of a detector head and reports a fault

• Continues to work during unauthorised removal of detectors

• Quick and simple installation

Discovery SounderBeacon Base The Discovery Sounder Beacon Base makes full use of the Discovery protocol. For ease of commissioning a ‘magnetic wand’ can be used to test and adjust each sounder locally.

• It is possible to set individual control of the sounder and beacon

• Volume and tone settings can be selected from the control panel

• Tones can be used for other purposes in addition to warning of fire, ideal for schools

• Enables soft start option, ideal for hospitals and nursing homes

• Electronicbelltone

Sounder Beacon Base with Isolator † 45681-330

Sounder Beacon Base † 45681-331

Sounder Beacon Base 45681-336with Australian Tone †

Sounder Beacon Base with NZ Tone † 45681-338

Sounder Beacon Base Slow Whoop 45681-332with Isolator †

Sounder Beacon Base 45681-334with Isolator DIN-Tone

White Cap †‡ 45681-292

Red Cap †‡ 45681-293

AlarmSense Sounder Beacon Base LR 45681-340

AlarmSense Sounder Beacon Base 45681-509

Red Cap 45681-295

White Cap 45681-294

Discovery Sounder Beacon Base 45681-393

SOUNDER BEACON BASES

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

‡ Does not have CPD approval

Audio Visual Signalling66

AudioVisual Accessoriesaudio visual signalling

AV ACCESSORIES

Audio Visual Signalling 67

Beacon Enclosure The Beacon Enclosure is weatherproof allowing a loop-powered beacon to be installed outside and in high moisture environments such as swimming pools.

• Can be installed outside

• IP 67

Magnetic Wand The Magnetic Wand is used to initiate and terminate actions such as adjusting and setting the sound levels of the Discovery Sounder Beacon Base.

• Flexibility to set sound output to desired level during walk test

• Allows local testing of Discovery Sounder Beacon Bases

• 1.2m when extended

Beacon Enclosure 29600-318

Magnetic Wand 29650-001

AV ACCESSORIES

Please check the Apollo website on a regular basis for up-to-date approvals information.

Interfaces 68

Interfaces

Apollo manufactures a comprehensive range of

interfaces for intelligent systems which enable fire

protection systems to be engineered simply and

effectively without the need for custom-designed

equipment. There are a variety of interfaces

available to suit a number of individual applications.

Interfaces 69

Standard Interfaces are fitted with

bi-directional short-circuit isolators so

that they are unaffected by a single

short circuit on either loop input or

output. The exception to this is the

Mains Input/Output unit which is not

isolated.

Key features of Apollo Interfaces:

• Easytoinstall

• Wellprotected

• Modulardesign

• Aneatsolution

Standard Interfaces

STANDARD INTERFACES

Interfaces 70

Input/OutputUnitThe Input/Output unit provides a voltage free, double pole change-over (DPCO) relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input.

• It can report fault, switch open and switchclosed levels

• Three visible LEDs

• Loop powered

• Voltage free

• Capable of switching up to 30V at 1A

STANDARD INTERFACES

ThreeChannelInput/OutputUnitThe Three Channel Input/Output Unit provides three voltage-free, single pole, change-over relay outputs and three monitored switch inputs.

• Supervises one or more normally-open switches on each of the three inputs

• Loop powered

• Capable of switching up to 30V at 1A on each of the three outputs

OutputUnitThe Output Unit provides a voltage-free single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs.

• Capable of switching up to 30V at 1A

SounderControlUnitThe Sounder Control Unit is used to control the operation of a zone of conventional sounders and report their status to the control panel.

• Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off

• May be synchronised when in pulsed operation

Input/OutputUnit 55000-847

OutputUnit 55000-849

SounderControlUnit 55000-852

ThreeChannelInput/OutputUnit55000-588

Please check the Apollo website on a regular basis for up-to-date approvals information.

Interfaces 71

STANDARD INTERFACES

SwitchMonitorPlusThe Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Output for resetting a remote detector

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Two visible LEDs

• Selectable alarm delay for monitoring flow switches

ZoneMonitorThe Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop.

• Loop powered

• Visible LED

SwitchMonitorThe Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Two visible LEDs

• Loop powered

SwitchMonitor 55000-843

ZoneMonitor 55000-845

SwitchMonitorPlus 55000-841

Please check the Apollo website on a regular basis for up-to-date approvals information.

*Not isolated

MainsSwitchingInput/OutputUnit*The Mains Switching Input/Output Unit provides a voltage-free, single pole change-over relay output and a monitored switch input.

• Supervises one or more normally-open switches connected to a single pair of cables

• Three visible LEDs

• Capable of switching 250V AC at up to 5A

MainsSwitchingInput/OutputUnit 55000-875

Interfaces 72

STANDARD INTERFACES

With the exception of the Mains Switching Input/Output Unit Apollo’s range of standard interfaces without Isolators has been discontinued. The alternatives are listed below.

Comparisonchart

ProductName PartNumber

WithoutIsolator WithIsolator

Input/Output Unit 55000-818 55000-847

Three Channel Input/Output Unit 55000-589 55000-588

Output Unit 55000-819 55000-849

Sounder Control Unit 55000-823 55000-852

Switch Monitor 55000-810 55000-843

Switch Monitor Plus 55000-809 55000-841

Zone Monitor 55000-813 55000-845

Mains Switching I/O Unit 55000-875 N/A

Please check the Apollo website on a regular basis for up-to-date approvals information.

Interfaces 73

MINI INTERFACES

Mini Interfaces use very compact

enclosures for installation into other

equipment.

Mini Interfaces

Interfaces 74

MiniSwitchMonitorThe New Mini Switch Monitor is an interface within an entirely new housing. This allows the unit to be fitted onto a standard 35mm DIN-Rail (using a twist-click motion) or mounted within an enclosure, for example a manual call point. It is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Designed for use where space is limited

• Isolated as standard

• Interrupt/non interrupt in one unit

• ‘Pre-alarm’ status available

• Three, coloured LEDs, giving clear status indication

MINI INTERFACES

MiniSwitchMonitorwithflyleadsThe Mini Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Visible LED with remote LED connection option

• Loop powered

• Designed for use where space is limited

• Easy to install

MiniSwitchMonitorwithflyleads(Interrupt) The Mini Switch Monitor (Interrupt) is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment. It can also place a current pulse in the ‘interrupt’ bit to signal the operation of a manual call point.

• Three input states - ’normal’, ’fault’ and ’alarm’

• Visible LED with remote LED connection option

• Loop powered

• Designed for use where space is limited

• Easy to install

• Monitors equipment where a fast response is required

• Interrupt facility

MiniSwitchMonitor 55000-760

MiniSwitchMonitor 55000-833

MiniSwitchMonitor(Interrupt) 55000-832

*Please check the Apollo website for up-to-date approvals information.

Interfaces 75

DIN-RAIL INTERFACES

DIN-Rail Interfaces feature enclosures

that clip to standard 35mm DIN-Rails

or are screwed to the base of a larger

enclosure. They enable fire system

designers to determine the functions

required and create multi-purpose

interfaces for individual sites. DIN-Rail Interfaces

Interfaces76

DIN-RailInput/OutputUnitThe DIN-Rail Input/Output Unit provides a voltage free, single pole, change-over relay output, a single, monitored switch input and an unmonitored, non-polarised opto-coupled input.

• It can report fault, switch open and switchclosed levels

• Three visible LEDs

• Loop powered

• Voltage free

• Capable of switching up to 30V at 1A

DIN-RailOutputUnitThe DIN-Rail Output Unit provides a voltage-free single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs.

• Capable of switching up to 30V at 1A

DIN-RailSwitchMonitorThe DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Two visible LEDs

• Loop powered

DIN-RAIL INTERFACES

DIN-RailInput/OutputUnit 55000-803

DIN-RailOutputUnit 55000-804

DIN-RailSwitchMonitor 55000-822

NEW!!DIN-RailSounderController(5 Amperes)The DIN-Rail Sounder Controller (5 Amperes) is used to control the operation of a zone of externally powered sounders and report their status to the control panel.

• Allowssounderstobeoperatedcontinuouslyor be pulsed, 1 second on, 1 second off

• Maybesynchronisedwheninpulsedoperation

• Anopto-coupledinputisprovidedtomonitorthe state of the external power supply.

• Sounderscanbeoperatedindividuallyoringroups

• Willacceptaloadof5amperes

NEW!!DIN-RailMainsInput/OutputUnitThe DIN-Rail Mains Input/Output Unit provides a voltage-free, single pole change-over relay output and a monitored switch input. The Unit supervises one or more normally-open switches connected to a single pair of cables.

• It can report fault, switch open and switch closed levels

• Three visible LEDs

• Capable of switching up to 8A at 240V AC

• Fits a standard 35mm DIN-Rail

DIN-RailMainsInput/OutputUnit 55000-797

DIN-RailSounderController(5Amp) 55000-182

Please check the Apollo website on a regular basis for up-to-date approvals information.

Interfaces 77

DIN-RAIL INTERFACES

DIN-RailDualIsolatorThe DIN-Rail Dual Isolator provides two independent Isolators which sense and isolate short circuits on Discovery or XP95 loops and spurs.

• Loop powered

• Polarity sensitive

• Up to 20 detectors can be installed between isolators

• Allows fully isolated spurs

DIN-RailDualIsolator 55000-802

DIN-RailAccessories:

MiniSwitchMonitorThe Mini Switch Monitor is an interface within an entirely new housing. This allows the unit to be fitted onto a standard 35mm DIN-Rail (using a twist-click motion) or mounted within an enclosure, for example a manual call point. It is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Designed for use where space is limited

• Isolated as standard

• Interrupt/non interrupt in one unit

• ‘Pre-alarm’ status available

• Three, coloured LEDs, giving clear status indication

MiniSwitchMonitor 55000-760

ProductName PartNumber PageNo.

DIN-Rail Interface Enclosure (4 units) 29600-239 85

DIN-Rail Interface Enclosure (10 units) 29600-240 85

DIN-Rail End Stops 27447-528

DIN-RailSwitchMonitorPlusThe DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

• Output for resetting a remote detector

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Two visible LEDs

• Loop powered

• Selectable alarm delay for monitoring flow switchesDIN-RailSwitchMonitorPlus 55000-821

DIN-RailZoneMonitor withIsolatorThe Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop.

• Loop powered

• Visible short circuit LED

• Built in Isolator

DIN-RailZoneMonitorwithIsolator 55000-812

Please check the Apollo website on a regular basis for up-to-date approvals information.

Manual Call Points78

Manual Call Points

MANUAL CALL POINTS

Manual Call Points 79

MANUAL CALL POINTS

DiscoveryManualCallPointThe Discovery Manual Call Point is compliant with EN54-11. The Call Point can be addressed at the commissioning stage by means of a seven-segment DIL switch. When operated, the manual call point interrupts the polling cycle for a fast response.

DiscoveryManualCallPoint(non-standard)In addition to the standard Discovery Manual Call Point, Apollo offer a selection of differently coloured call points, suitable for a variety of different applications.

• Flashing LED option

• Plug and play terminal connections for fast wiring

• Allow wiring continuity testing before fitting

• Reports an alarm in under 0.2 seconds

• Resettableelement

• Flashing LED option

• Plug and play terminal connections for fast wiring

• Allow wiring continuity testing before fitting

• Reports an alarm in under 0.2 seconds

• Resettableelement

XP95ManualCallPointThe XP95 Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. The device features plug and play terminal connections and a resettable element.

• Plug and play terminal connections for fast wiring

• Allow wiring continuity testing before fitting

• Reports an alarm in under 0.2 seconds

• Resettableelement

TransparentHingedCoverThe Transparent Hinged Cover is for use with XP95 and Discovery Manual Call Points and can be fitted to add further protection against accidental operation.

• Locking tag

• Reduces risk of vandalism

* Please note - the manual call point does not complywith EN54 when fitted with this cover.

DiscoveryManualCallPoint 58100-910(Surface)

DiscoveryManualCallPoint 58100-908withIsolator(Surface)

DiscoveryManualCallPoint 58100-926(NonStandard)White(Surface)

DiscoveryManualCallPoint 58100-927(NonStandard)Yellow(Surface)

DiscoveryManualCallPoint 58100-928(NonStandard)Blue(Surface)

DiscoveryManualCallPoint 58100-929(NonStandard)Green(Surface)

XP95ManualCallPoint 55100-905(Surface)

XP95ManualCallPoint 55100-908withIsolator(Surface)

TransparentHingedCover 26729-152

Please check the Apollo website on a regular basis for up-to-date approvals information.

MANUAL CALL POINTS

Manual Call Points80

AlarmSenseManualCallPointThe AlarmSense Manual Call Point is compliant with EN54:11. It is different from other conventional call points in that it can be detected as an operated call point rather than a detector that has changed to the alarm state.

• Gives immediate response

• Unique identification signalling

• Resettable element

XPanderManualCallPointThe XPander Manual Call Point is compliant with EN54:11. It is wireless and is powered by two independent packs of 3 AA alkaline batteries with a typical three year life.

• Uses patented XPERT addressing

• Resettable element

• Reports an alarm in under one second

AlarmSenseManualCallPoint 55100-894(Surface)

XPanderManualCallPoint XPA-MC-14006-APO

MANUAL CALL POINTS

WaterproofManualCallPointThe Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. It is compliant with EN54-11 and can be used with the XP95 and Discovery ranges.

• Plug and play terminal connections for fast wiring

• Allow wiring continuity testing before fitting

• Resettableelement

• IP67

WaterproofManualCallPoint 58100-950

WaterproofManualCallPoint 58100-951withIsolator

WaterproofManualCallPoint 58100-953withIsolator(Yellow)†

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have CPD approval

MANUAL CALL POINTS

Manual Call Points 81

MANUAL CALL POINTS

Please check the Apollo website on a regular basis for up-to-date approvals information.

Mounting Accessories 82

MountingAccessories

Mounting Accessories 83

BackplateThe Backplate provides a high degree of protection against the ingress of water or dust into the back of the detector mounted directly onto a mounting box. When the backplate is used with an XP95 device, the number tab of the XPERT card must be snapped off and placed in one of the knockout slots provided in the backplate.

• Protects against water ingress

• Improved performance

• Fits Discovery, XP95, Orbis, Series 65 and AlarmSense bases

BaseCoverBase Covers are available as part of the Series 65 and XP95 ranges.

• Protects base when detector not in situ

• Aesthetically pleasing

ConduitBoxThe Conduit Box is a versatile accessory for surface mounting Apollo bases. The box has knockouts to accept PG16 or M20 cable glands, conduit or mini-trunking. Self-tapping screws are included to fit the detector base to the conduit box.

• Easy to install

• Aesthetically pleasing

SounderCeilingPlateThe Sounder Ceiling Plate allows surface mounted cabling to be fitted to a loop powered sounder base.

• Ease of installation

• Ideal for use with concrete ceilings where drilling is not permissible

ModuleBaseThe Module Base is an accessory which can be secured to a standard base allowing customers to fit their own electronics.

• 5mmindepth

MOUNTING ACCESSORIES

Backplate 45681-233

ConduitBox 45681-204

SounderCeilingPlate 45681-311

ModuleBase 38531-822

Series65BaseCover 45681-370

XP95BaseCover 45681-380

Please check the Apollo website on a regular basis for up-to-date approvals information.

Mounting Accessories 84

DeckheadMountingBoxesThe Deckhead Mounting Box gives extra protection to devices to be fitted in areas where there is the possibility of moisture or condensation ingressing through the rear of the of the base. The new version is suitable for a wider range of detector bases as well as Apollo’s AV bases.

• Protectsagainstwateringress

• Improvedperformance

• Availableinpolycarbonateormetal

• PolycarbonateDeckheadMountingBox45681-217 also fits Apollo Audio Visual bases

MOUNTING ACCESSORIES

CeilingTileMountingBoxThe Ceiling Tile Mounting Box has been designed to make the installation of detectors and sounders quick and easy prior to the fitting of a false ceiling. Detector and sounder bases can be fitted, wired and, if necessary, tested and commissioned before the installation of a false ceiling.

• No need for separate backbox

• Can be used with tiles up to 25mm thick

• Quick and easy installation

BeaconEnclosureThe Beacon Enclosure is weatherproof allowing a loop-powered beacon to be installed outside and in high moisture environments such as swimming pools. The enclosure is supplied with a mounting bracket to accept a Discovery or XP95 base.

• Protects against water ingress

• Allows beacon to be used outdoors

• Accepts MiniDisc remote indicator

• IP67

NEW!!DeckheadMountingBox 45681-217MetalDeckheadMountingBox 29600-131(hasaccessportsthreadedtofit PG16glands)

MetalDeckheadMountingBox 29600-139(hasaccessportsthreadedtofit M20components)

DeckheadAdaptor(forusewith 27249-00529600-196-convertscableglands fromPG16toM20)

DetectorCeilingTileMountingBox 45681-309

SounderCeilingTileMountingBox 45681-310

BeaconEnclosure 29600-318

Please check the Apollo website on a regular basis for up-to-date approvals information.

Mounting Accessories 85

MOUNTING ACCESSORIES

1.5mmHexagonalDriverThe 1.5mm Hexagonal Driver is used to turn the locking screw fitted to Discovery, XP95 and Series 65 detectors.

• Allows detectors to be fitted with ease

Series90toXP95BaseAdaptorThe XP95 Base Adaptor is designed to allow XP95 detectors to be fitted to an existing Series 90 base. The adaptor eliminates the need to rewire an existing Apollo intelligent system.

• Allows an existing range to be updated with ease

• Eliminates the need for re-wiring

Series65toOrbisBaseAdaptorThe Orbis Adaptor is designed to allow Orbis detectors to be fitted to an existing Series 60 or Series 65 base. The adaptor eliminates the need to rewire an existing Apollo conventional system.

• Allows an existing range to be updated with ease

• Eliminates the need for re-wiring

DIN-RailInterfaceEnclosuresDIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-rail mounted interfaces. A multi-purpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.

• Allows multiple interfaces to be housed together

• IP67

DIN-RailInterfaceEnclosure(4units) 29600-239

DIN-RailInterfaceEnclosure(10units)29600-240

1.5mmHexagonalDriver 29600-095

Series90toXP95BaseAdaptor 45681-238

Series65toOrbisBaseAdaptorORB-BA-10008-APO

Please check the Apollo website on a regular basis for up-to-date approvals information.

Marine 86

Marine

Apollo offer both conventional and intelligent ranges of

smoke and heat detectors which are approved for use

in the marine environment. These detectors operate in

the same way and carry the same approvals as standard

detectors but are subject to additional approvals tests,

specific to the marine environment.

The marine detectors are approved by the following bodies:

• American Bureau of Shipping

• Bureau Veritas

• China Classification Society

• Det Norske Veritas

• Germanischer Lloyd

• Lloyd’s Register of Shipping

• Maritime and Coastguard Agency

• Marine Marchande Française

Marine 87

Discovery Marine intelligent fire

detectors are suitable for larger

vessels. The high specification range

has been developed to meet the

requirements of sophisticated systems.

Discovery gives you total reassurance

in installations where it is necessary to

adapt detection to different operating

environments and where protection

against unwanted alarms is paramount.

KeyfeaturesofDiscoveryMarine:

• Approvedforuseinthemarineenvironment

• Fiveresponsemodesforenvironmentaladaptation

• Day/Nightswitchingforincreasedreliability

• Driftcompensationforfalsealarmreduction

• Userprogrammabilityfordataretention

• XPERTcardaddressingforincreasedsecurity

Discovery marine

DISCOVERY MARINE

Marine88

DiscoveryMarine IonisationSmokeDetectorThe Discovery Marine Ionisation Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chamber and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Remote test feature

• Rejection of transient signals

DISCOVERY MARINE

DiscoveryMarine OpticalSmokeDetectorThe Discovery Marine Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Suitable for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

• Remote test feature

• Rejection of transient signals

DiscoveryMarineHeatDetectorThe Discovery Marine Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector.

• Ideal in environments that are dirty or smoky

• Unaffected by wind or atmospheric pressure

• Remote test feature

• Rejection of transient signals

DiscoveryMarineMultisensorDetectorThe Discovery Marine Multisensor detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. As a result, the multisensor is useful over a wide range of applications and is highly immune to false alarms.

• Ideal for a wide range of applications

• Highly immune to false alarms

• Unaffected by wind or atmospheric pressure

• Remote test feature

• Rejection of transient signals

DiscoveryMarineOpticalSmokeDetector 58000-600MAR

DiscoveryMarineHeatDetector 58000-400MAR

DiscoveryMarineMultisensorDetector 58000-700MAR

DiscoveryMarineIonisationSmokeDetector 58000-500MAR

Please check the Apollo website on a regular basis for up-to-date approvals information.

Marine 89

DISCOVERY MARINE

DiscoveryMarineManualCallPointThe Discovery Marine Manual Call Point has been approved for use in indoor marine applications such as cruise liners. When operated, the manual call point interrupts the polling cycle for a fast response.

• Reports an alarm in under 0.2 seconds

• Resettable element

DiscoveryMarineIsolatorThe Discovery Marine Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power in the isolated section.

• Detects wiring short circuits using patented technology

• Minimises disruption from short-circuits

• Automatic de-isolation on short-circuit removal

• The equivalent of up to 20 smoke detectors may be installed between isolators

DiscoveryMarineIsolatorBaseThe Discovery Marine Isolator Base is unique and designed to only accept the marine isolator.

• Only accepts the Marine Isolator

DiscoveryMarineMountingBaseAll detectors in the Discovery Marine range are for use with the Marine Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

• XPERT addressing

• One way fit

• Locking feature to prevent unauthorised removal

DiscoveryMarineMountingBase 45681-210MAR

DiscoveryMarineManual 58100-970MARCallPoint

DiscoveryMarineManual 58100-971MARCallPointwithIsolator

DiscoveryMarineIsolator 55000-700MAR

DiscoveryMarineIsolatorBase 45681-211MAR

Please check the Apollo website on a regular basis for up-to-date approvals information.

Marine90

ORBIS MARINE

Orbis Marine conventional fire detectors

offer a wealth of features to save time,

enhance reliability and reduce false

alarms within the marine environment.

These include drift compensation and

DirtAlert®, a feature that warns service

engineers via a flashing yellow LED

that detectors need maintenance;

and patented FasTest®, a procedure

that takes just four seconds to test

smoke detectors and confirm that they

are functioning correctly.

KeyfeaturesofOrbisMarine:

• Approvedforuseinmarineenvironments

• Modern,low-profiledesign

• TImeSaverBase®forfastinstallation

• Transientrejectionforfalsealarmreduction

• Highhumiditytoleranceatupto98%RH

• Wideoperatingtemperature-40°Cto+70°C

Orbismarine

Marine 91

ORBIS MARINE

OrbisMarineOpticalSmokeDetectorThe Orbis Marine Optical Smoke Detector operates on the well established light scatter principle. However, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms.

• Responds well to slow-burning, smouldering fires

• Performs well in detecting black and white smoke

• Extra confirmation of smoke before alarm signal is given

• Reduced incidents of false alarms

• Sensing chamber keeps out dust and other airborne contaminants

• Operates over a broad voltage range of at extremes of temperature

• Flashing LED option

OrbisMarineMultisensorDetectorThe Orbis Marine Multisensor Detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone.

• Responds well to fast-burning, flaming fires

• Reducedincidenceoffalsealarms

• Increasedreliabilityofdetection

• Sensingchamberkeepsoutdustandotherairborne contaminants

• Operatesoverabroadrangeofvoltagesatextremes of temperature

• FlashingLEDoption

OrbisMarineOpticalSmoke ORB-OP-42001-MARDetector

OrbisMarineOpticalSmoke ORB-OP-42003-MARDetectorwithflashingLED

OrbisMarineMultisensor ORB-OH-43001-MARSmokeDetector

OrbisMarineMultisensor ORB-OH-43003-MAR SmokeDetectorwithflashingLED

OrbisMarineHeatDetectorThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.

• Can be used for applications where smoke detectors are unsuitable

• Idealforenvironmentsthataredirtyorsmokyunder normal conditions

• Reducedincidencesoffalsealarms

• Increasedreliabilityofdetection

• FlashingLEDoptionOrbisMarineHeatDetector

A1RStandard ORB-HT-41001-MARA1RwithFlashingLED ORB-HT-41013-MAR

A2SStandard ORB-HT-41002-MARA2SwithFlashingLED ORB-HT-41014-MAR

BRStandard ORB-HT-41003-MARBRwithFlashingLED ORB-HT-41015-MAR

BSStandard ORB-HT-41004-MARBSwithFlashingLED ORB-HT-41016-MAR

CRStandard ORB-HT-41005-MARCRwithFlashingLED ORB-HT-41017-MAR

CSStandard ORB-HT-41006-MARCSwithFlashingLED ORB-HT-41018-MAR

Please check the Apollo website on a regular basis for up-to-date approvals information.

Marine92

OrbisMarineTimeSaverBase®

The Orbis Marine TimeSaver Base® is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

ORBIS MARINE

OrbisMarineRelayBaseThe Orbis Marine Relay Base incorporates a single-pole voltage-free change over contact for switching ancillary equipment. When the detector changes to the alarm state, the relay is energised, causing the contact to change state. The contact will remain in this condition until the detector is reset.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

OrbisMarineTimeSaver ORB-MB-00001-MARBase®

OrbisMarineRelayBase ORB-RB-40004-MAR

Please check the Apollo website on a regular basis for up-to-date approvals information.

Marine 93

ORBIS MARINE

Please check the Apollo website on a regular basis for up-to-date approvals information.

Intrinsically Safe Detectors94

There are many places where an explosive mixture of air and gas or

vapour is, or may be present continuously, intermittently or as a result of

an accident. These are defined as hazardous areas by BS EN 60079, the

code of practice for installation and maintenance of electrical apparatus

in potentially explosive atmospheres.

Hazardous areas are common in petroleum and chemical engineering

plants and in factories processing and storing gases, solvents, paints and

other volatile substances.

Electrical equipment for use in these areas needs to be designed so

that it cannot ignite an explosive mixture, not only in normal operation

but also in fault conditions. There are a number of methods available to

achieve this but one of the most common is intrinsic safety.

Apollo offer both conventional and intelligent smoke and heat detector

ranges designed to be intrinsically safe, as they meet the requirements

of the ATEX directive.

Intrinsically SafeDetectors

Intrinsically Safe 95

XP95 Intrinsically Safe (IS) detectors

are a development of the well

established intelligent XP95 range

from Apollo. XP95 IS detectors feature

all the benefits of the standard range,

but are developed specifically for use

in hazardous areas. The addresses of

XP95 IS detectors are set by means of

the patented XPERT card. See page 23

for more details.

XP95 ISIntrinsically Safe

Detectors

XP95 IS

Intrinsically Safe 96

XP95ISIonisationSmokeDetectorThe XP95 IS Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Minimal effects from temperature, humidity, atmospheric pressure and wind

XP95 IS

XP95ISOpticalSmokeDetectorThe XP95 IS Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Wellsuitedforescaperoutes

• Unaffectedbywindoratmosphericpressure

XP95ISHeatDetectorThe XP95 IS Heat Detector operates by measuring heat levels with a single thermistor network which gives a count output proportional to the external air temperature.

• Ideal for environments that are dirty or smoky under normal conditions

• Unaffected by wind or atmospheric pressure

XP95ISMountingBaseThe XP95 IS Mounting Base has been designed to accept only IS products. This ensures that standard detectors cannot inadvertently be fitted into an intrinsically safe system. XPERT cards are supplied with all bases.

• XPERT addressing

• Onewayfit

• OnlyacceptsISdetectors

XP95ISManualCallPoint-StandardTypeThe XP95 IS Manual Call Point is based on the standard waterproof model (58100-950), page 80. It features an “interrupt” facility to provide fast response to an alarm.

• Reports an alarm in under 0.2 seconds

• Waterproof

• IP67

XP95ISIonisationSmokeDetector 55000-540

XP95ISOpticalSmokeDetector 55000-640

XP95ISHeatDetector 55000-440

XP95ISMountingBase 45681-215

XP95ISManualCallPointStandard

Withoutflap–Red 55100-940

Withoutflap–Yellow † 55100-942

WithoutflapBlue/White † 55100-944

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have LPCB or CPD approval

Intrinsically Safe 97

XP95 IS

XP95ISManualCallPoint-MEDCStyleThe MEDC style Manual Call Point is recommended for heavy duty applications. This model is made of glass-reinforced polyester and may be ordered as break glass or push-button style.

• Reports address in under 0.2 seconds

• Waterproof

• Robust design

ProtocolTranslatorandGalvanicBarrierThe Protocol Translator and Galvanic Barrier are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals.

• Loop powered

• Translates voltage levels from a loop driver to be compatible with IS requirements

XP95ISManualCallPointMEDCStyle

Break-glass–Red 55000-960

Break-glass–Yellow 55000-962

Break-glass–Blue 55000-964

Break-glass–Black/YellowStripes 55000-966

Break-glasswithflap–Red 55000-961

Break-glasswithflap–Yellow 55000-963

Break-glasswithflap–Blue 55000-965

Break-glasswithflap –Black/YellowStripes 55000-967

PushButton–Red 55000-970

PushButton–Yellow 55000-971

PushButton–Blue 55000-972

PushButton–Black/Yellowstripes 55000-973

XP95ProtocolTranslator 55000-855(singlechannel)

XP95ProtocolTranslator 55000-856(dualchannel)

GalvanicBarrier 29600-098

DIN-RailInterfaceEnclosuresDIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-rail mounted interfaces. A multi-purpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.

• Allows multiple interfaces to be housed together

• IP67

DIN-RailInterfaceEnclosure(4units) 29600-239

DIN-RailInterfaceEnclosure(10units)29600-240

Please check the Apollo website on a regular basis for up-to-date approvals information.

Intrinsically Safe 98

ORBIS IS

Orbis IS is a range of conventional

detectors which have been developed

from the standard Orbis smoke and

heat detectors. Orbis IS is a range with

modern styling and is electronically

compatible with Apollo Series 60

intrinsically safe conventional detectors.

Orbis IS is a demonstration of Apollo’s

commitment to the market for high

quality conventional detectors for use

in small to medium size installations.

In developing this range, Apollo has

put ease of installation and reliability

in daily operation at the forefront of

considerations.

Featuresinclude:

• TimeSaverBase®

• PatentedFasTest®enablingfunctionaltestinginfour

seconds

• DirtAlert®indicateslimitofdriftcompensation

• Toleratesextremeoperatingconditions:-40°Cto+70°C

• Falsealarmreduction

• FlashingLEDoption

Orbis ISintrinsically safe

Intrinsically Safe 99

OrbisISOpticalSmokeDetectorThe Orbis IS Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Reduces false alarms

• Recommended for early warning of fire in most areas

• Improved sensitivity to black smoke

• Compensation for slow changes in sensitivity

• Algorithms for reliability of alarm

ORBIS IS

OrbisISOpticalSmoke ORB-OP-52027-APODetector

OrbisISOpticalSmoke ORB-OP-52028-APO DetectorwithflashingLED †

OrbisISMultisensorSmokeDetectorThe Orbis IS Multisensor Detector benefits from the same false alarm technology as the Optical Detector. It is a thermally enhanced smoke detector so will not give an alarm from heat alone.

• Reducesfalsealarms

• Sensitivetofastburning,flamingfires

• Improvedsensitivitytoblacksmoke

• Compensationforslowchangesinsensitivity

• AlgorithmsforreliabilityofalarmOrbisISMultisensor ORB-OH-53027-APODetector

OrbisISMultisensor ORB-OH-53028-APODetectorwithflashingLED †

OrbisISHeatDetectorThe Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.

• Canbeusedforapplicationswheresmokedetectors are unsuitable

• Idealforenvironmentsthataredirtyorsmokyunder normal conditions

• Reducedincidencesoffalsealarms

• Increasedreliabilityofdetection

OrbisISHeatDetector

RateofRise,MAT50°CA1RStandard ORB-HT-51145-APOA1RwithFlashingLED † ORB-HT-51146-APO

Static,MAT50°CA1SStandard ORB-HT-51157-APOA1SwithFlashingLED † ORB-HT-51158-APO

Static,MAT50°CA2SStandard ORB-HT-51147-APOA2SwithFlashingLED † ORB-HT-51148-APO

RateofRise,MAT65°C BRStandard ORB-HT-51149-APOBRwithFlashingLED † ORB-HT-51150-APO

Static,MAT65°C BSStandard ORB-HT-51151-APOBSwithFlashingLED † ORB-HT-51152-APO

RateofRise,MAT80°C CRStandard ORB-HT-51153-APOCRwithFlashingLED † ORB-HT-51154-APO

Static,MAT80°C CSStandard ORB-HT-51155-APOCSwithFlashingLED † ORB-HT-51156-APO

MAT(MaximumApplicationTemperature)

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

Intrinsically Safe 100

ORBIS IS

OrbisISTimeSaver®BaseThe IS TimeSaver® Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Detector locking mechanism

OrbisISAdaptorThe Orbis IS Adaptor enables Orbis IS detector heads to be fitted into existing Series 60 IS bases in order to upgrade systems with minimal disruption.

• Allows an existing range to be updated with ease

• Eliminates the need for re-wiring

OrbisISTimesaver®Base ORB-MB-50018-APO

OrbisISAdaptor ORB-BA-50008-APO

GalvanicBarrierThe Galvanic barrier is installed in the safe area and ensures system integrity.

• Ideal for conventioanl hazardous areas

• Enables compliance with the ATEX directive

GalvanicBarrier 29600-378

DIN-RailInterfaceEnclosuresDIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-rail mounted interfaces. A multi-purpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.

• Allows multiple interfaces to be housed together

• IP67

DIN-RailInterfaceEnclosure(4units) 29600-239

DIN-RailInterfaceEnclosure(10units)29600-240

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have VdS approval

Intrinsically Safe 101

ORBIS IS

UL102

UL

Apollo has developed ranges of detectors for the

American market and those markets which require

UL classification. Apollo has carefully researched

and developed the ranges to ensure that they meet

not only the UL and other standards but also the

demands of today’s high technology environments.

UL 103

The XP95A range of analog

addressable fire detectors is advanced

in design and performance and offers

unique features that benefit both the

installer and the end user.

The range is based on Apollo’s XP95 range. XP95A has a

‘central intelligence’ system where all the decisions are made

by the control panel. Each detector is addressed using Apollo’s

patented XPERT card, supplied with the mounting bases. The

XP95A range includes an ionization detector, a photo-electric

detector, a heat detector, a multisensor, an isolator and a

series of modules.

KeyfeaturesofXP95Ainclude:

• XPERTcardaddressing

• Analogvaluereport

• Addressconfirmation

• Alarmflag

• Unobtrusivedesign

• Errorcheck

XP95AUL

XP95A

UL104

XP95A

XP95AIonizationSmokeDetectorThe XP95A Ionization Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Minimal effects from temperature, humidity, atmospheric pressure

XP95AIonizationSmokeDetector† 55000-550

XP95AIonizationSmokeDetector(ULC)*55000-555

XP95APhoto-ElectricSmokeDetectorThe XP95A Photo-Electric Smoke Detector works on the light-scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by atmospheric pressure

XP95APhoto-ElectricSmokeDetector55000-650

XP95AHeat DetectorThe XP95A Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. It is classified as an Ordinary detector by UL.

• Ideal environments that are dirty or smoky under normal conditions

• Well suited for warehouses, loading bays and car parks

• Unaffected by wind or atmospheric pressure

XP95AHeat Detector 55000-450

XP95AMultisensorThe XP95A Multisensor contains a photo-electric smoke sensor and a thermistor (temperature sensor) whose outputs are combined to give the final analog value.

• Sensitive to a wide range of fires

• Well suited for environments such as hotel bedrooms or warehouse loading bays

• Unaffected by wind or atmospheric pressure

XP95AMultisensor 55000-886

XP95ALoopPoweredBeamDetectorThe XP95A Beam Detector is made up of three main parts: the transmitter, which projects a beam of infra-red light, the receiver, which registers the light and produces an electric signal, and the interface, which processes the signal and generates alarm or fault signals.

• Loop-powered

• Four selectable alarm levels

• Drift Compensation

• Remote interface

• Simple wiring and alignment

• Designed to protect large open spaces such as museums, churches and warehouses

XP95ALoopPoweredBeamDetector55000-266

Please check the Apollo website on a regular basis for up-to-date approvals information.

† Does not have ULC approval

* Does not have UL approval

UL 105

XP95A

XP95AMountingBaseAll detectors in the XP95A range fit the XP95A Mounting Base which is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

• XPERT addressing

• One way fit

• Locking feature to prevent unauthorised removal

XP95AMountingBase4” 45681-210USA

XP95AMountingBase6” 45681-225USA

E-ZFitBaseThe E-Z fit base is a low profile 6” mounting base for XP95A detectors.

• Highdegreeofprotectionagainst unauthorized removal

E-ZFitBase 45681-250

XP95AIsolatingBaseThe XP95A Isolating Base senses and detects short circuit faults on XP95A loops and spurs.

• Upto20devicesmaybeinstalledbetweenisolating bases

• XPERTaddressing

XP95AIsolatingBase 45681-321USA

XP95A IsolatorThe XP95A Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section.

• Detectswiringshort-circuitsusingpatentedtechnology

• Minimisesdisruptionfromshort-circuits

• Automaticde-isolationonshort-circuitremoval

• Upto20devicesmaybeinstalledbetweenisolators

XP95A Isolator 55000-750

XP95ALowPowerRelayBaseThe XP95A Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.

• Gives a set of voltage free contacts controlled by the remote output of a detector

• Draws negligible current

XP95ALowPowerRelayBase4” 45681-242UL

ForinformationonXPERTcards,pleaseseepage23.

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL106

XP95A

XP95AMiniPrioritySwitchMonitorModuleThe XP95A Mini Priority Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment. It can also place a signal on the loop to provide early warning if a device such as a pull station is operated.

• Three input states - ’normal’, ’fault’ and ’alarm’

• Visible LED with remote LED connection option

• Loop powered

• Designed to fit into equipment with limited space

• Easy to install

• Monitors equipment where a fast response is required

• Interrupt facilityXP95AMiniPrioritySwitch 55000-830MonitorModule

XP95AMiniSwitchMonitorModuleThe XP95A Mini Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment.

• Three input states - ’normal’, ’fault’, and ’alarm’

• Visible LED with remote LED connection option

• Loop powered

• Designed to fit into equipment with limited space

• Easy to install

XP95AMiniSwitchMonitorModule 55000-831

XP95ASwitchMonitorModuleThe XP95A Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts connected and to report the status to Apollo compatible analog control equipment.

• Three input states - ’normal’, ’fault’, and ’alarm’

• Visible LED

• Loop powered

XP95ASwitchMonitorModule 55000-805

XP95AIsolatorBaseThe XP95A Isolator Base is unique and designed to only accept the XP95A Isolator.

• Onlyacceptsisolators

XP95AIsolatorBase 45681-211USA

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL 107

XP95A

XP95ADualPrioritySwitchMonitorModuleThe XP95A Dual Priority Switch Monitor Module contains two priority switch monitor modules (55000-806) on a single plate.

• Looppowered

• Fastresponsetime

• Interruptfacility

XP95ADualPrioritySwitchMonitor 55000-790Module

XP95ASwitchMonitorInput/OutputModuleThe XP95A Switch Monitor Input/Output Module provides a voltage free, single pole, change-over relay output, a single, monitored switch input and unmonitored, non-polarized opto-coupled input.

• Itcanreportfault,switchopenandswitchclosed levels

• VisibleLED

• Looppowered

XP95ASwitchMonitor 55000-820Input/OutputModule

XP95ASounderControlModuleThe XP95A Sounder Control Module monitors and controls the operation of a zone of conventional sounders and reports their status to the control panel.

• Allowssounderstobeoperatedcontinuouslyor be pulsed, 1 second on, 1 second off

• Maybesynchronizedwheninpulsedoperation

• Canalsobeusedforpublicaddressspeakers

XP95ASounderControlModule 55000-825

XP95ARelayOutputModuleThe XP95A Relay Output Module provides a single 2-pole changeover relay.

• Looppowered

• Canbeplacedanywhereonloop

XP95ARelayOutputModule 55000-863

XP95APrioritySwitchMonitorModuleThe XP95A Priority Switch Monitor Module is designed to monitor the state of one or more single pole, volt free contacts and to report the status to Apollo compatible analog control equipment. It can also place a signal on the loop to provide early warning if a device such as a pull station is operated.

• Three input states - ’normal’, ’fault’, and ’alarm’

• Two visible LEDs

• Loop powered

• Fast response time

• Interrupt facility

XP95APrioritySwitchMonitor 55000-806Module

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL108

SERIES 65A

Series 65A is a range of conventional

fire detectors available in three

versions:

• Standard

• FlashingLED

• FlashingLEDandmagnetoperatedtestswitchSeries 65AUL

UL 109

SERIES 65A

Series65AIonizationSmokeDetector The Series 65A Ionization Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Respondswelltofastburning,flamingfires

• Designedtooperateinavarietyofenvironments

• Wideoperatingvoltage

• FlashingLEDoption

• FlashingLEDandmagnetoperatedtestswitchoption

Series65AIonizationSmokeDetector-Standard 55000-227

Series65AIonizationSmokeDetector 55000-226 withflashingLED

Series65AIonizationSmokeDetector 55000-225withflashingLEDandmagnetictestswitch

Series65APhoto-Electric SmokeDetectorThe Series 65A Photo-Electric Smoke Detector incorporates a pulsing LED located within the housing of the detector. The detector housing is identical to that of the Ionization Detector but has an indicator LED which is clear in quiescent state but produces red light in alarm.

• Respondswelltoslow-burning,smoulderingfires

• Wellsuitedforbedroomsandescaperoutes

• Unaffectedbywindoratmosphericpressure

• Wideoperatingvoltage

• FlashingLEDoption

• FlashingLEDandmagnetoperatedtest switch optionSeries65APhoto-ElectricDetector

-Standard 55000-327

Series65APhoto-ElectricDetector 55000-326withflashingLED

Series65APhoto-ElectricDetector 55000-325withflashingLEDandmagnetictestswitch

S65APhoto-ElectricHighSensitivity 55000-328

Series65AHeatDetectorThe Series 65A Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature.There are nine heat detectors in the Series 65A range designed to suit a wide variety of operating conditions.

• Canbeusedforapplicationswheresmokedetectors are unsuitable

• Idealenvironmentsthataredirtyorsmokyunder normal conditions

• Wideoperatingvoltage

• FlashingLEDoption

• FlashingLEDandmagnetoperatedtest switch optionSeries65AHeatDetector

135°F-Standard 55000-140135°F-flashingLED 55000-139135°F-flashingLEDandmagnetic 55000-138testswitch 170°F-Standard 55000-143170°F-flashingLED 55000-142170°F-flashingLEDandmagnetic 55000-141testswitch 200°F-Standard 55000-146200°F-flashingLED 55000-145200°F-flashingLEDandmagnetic 55000-144test switch

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL110

SERIES 65A

Series65AStandardBaseThe Series 65A Base has been designed to enable detectors to be fitted without the need of force – particularly useful when fitting to suspended ceilings. All Series 65A bases have a ‘one way only’ fit.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains a ground wire terminal

• Contains no electrical parts

Series65ABase4” 45681-200USA

Series65ABase6” 48681-220USA

Series65AStandardRelayBase4”The Standard Series 65A Relay Base provides one set of volt-free, changeover (form C) contacts that change state when the detector signals an alarm.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains a ground wire terminalSeries65AStandardRelayBase4” 45681-255

Series65AAuxiliaryRelayBase4”The Series 65A Auxiliary Relay Base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains a ground wire terminal

Series65AAuxiliaryRelayBase4” 45681-256

Series65AEnd-of-LineRelayBaseThe Series 65A End-of-Line (EOL) Relay Base is intended for use with 4-wire circuits and feature two sets of changeover contacts and a power supervision relay.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains a ground wire terminal

Series65A12VEnd-of-LineRelayBase4” 45681-257

Series65A24VEnd-of-LineRelayBase4” 45681-258

Series65ALowProfileBase6”A low profile mounting base for Series 65A detectors.

• Detector locking mechanism

• One way fit

• Easy to wire

• Contains a ground wire terminal

Series65ALowProfileBase6” 45681-232

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL 111

SERIES 65A

Series65AE-ZFitBase6”A low profile mounting base for Series 65A detectors.

• High degree of protection against unauthorized removal

Series65AE-ZFitBase6” 45681-251

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL112

DISCOVERY UL

Discovery UL is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery UL has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments, which reduces false alarms.

Each detector in the Discovery UL range can operate in

one of five response modes, which can be selected from

the control panel. The response characteristics have

been carefully set so that the detectors comply with the

requirements of the relevant part of UL in all response

modes. Mode One will give a higher sensitivity to fire

than Mode five.

Discovery gives you total reassurance in installations where

adaptability to changing conditions and protection against

unwanted alarms are paramount.

KeyfeaturesofDiscoveryULinclude:

• Rejectionoftransientsignals

• FlashingLEDoption

• Fiveresponsemodesforeaseofoptimizationto

changingenvironments

• Driftcompensationtoensureconstantsensitivity

• Fourbytesofnon-volatilememoryforuserdata

• Alarmflagforfastalarmreporting

• Conventionalalarmfacilityduringcontrolpanel

processor fault

• 360°visibilityinalarm

• CompatiblewithXP95Asystems

DiscoveryUL

UL 113

DISCOVERY UL

DiscoveryULIonizationSmokeDetector The Ionization detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

• Respondswelltofast-burning,flamingfires

• Designedtooperateinavarietyofenvironments

• Remotetestfeature

DiscoveryULIonizationSmoke 58000-550Detector

DiscoveryULPhoto-ElectricSmokeDetectorThe Discovery UL Photo-Electric Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

• Respondswelltoslow-burning,smoulderingfires

• Wellsuitedforbedroomsandescaperoutes

• Unaffectedbywindoratmosphericpressure

• RemotetestfeatureDiscoveryULPhoto-Electric 58000-650SmokeDetector

DiscoveryULHeatDetectorThe Discovery UL Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector.

• Idealenvironmentsthataredirtyorsmokyunder normal conditions

• Wellsuitedforwarehouses,loadingbaysandcar parks

• Unaffectedbywindoratmosphericpressure

• Remotetestfeature DiscoveryULHeatDetector 58000-450

DiscoveryULMultisensorDetectorThe Discovery UL Multisensor Detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analog value. As a result, the Multisensor is useful over a wide range of applications and is highly immune to false alarms.

• Idealforwiderangeofapplications

• Highlyimmunetofalsealarms

• Wellsuitedforsensitiveenvironments

• Unaffectedbywindoratmosphericpressure

• Remotetestfeature

DiscoveryULMultisensorDetector 58000-750

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL114

DISCOVERY UL

E-ZFitBaseThe E-Z Fit Base is a low profile 6” mounting base for Discovery UL detectors.

• Highdegreeofprotectionagainstunauthorisedremoval

E-ZFitBase 45681-250

XP95AIsolatingBaseThe XP95A Isolating Base senses and detects short circuit faults on Discovery UL loops and spurs.

• Upto20devicesmaybeinstalledbetweenisolating bases

XP95AIsolatingBase 45681-321USA

XP95A IsolatorThe XP95A Isolator can be used on a Discovery UL loop and is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section.

• Detectswiringshortcircuitsusingpatentedtechnology

• Minimisesdisruptionfromshort-circuits

• Automaticde-isolationonshort-circuitremoval

• Upto20devicesmaybeinstalledbetweenisolators

XP95AIsolator 55000-750

XP95AIsolatorBaseThe XP95A Isolator Base is unique and designed to only accept the XP95A isolator. However, both can be used with a Discovery UL system.

• OnlyacceptstheXP95AIsolator

XP95AIsolatorBase 45681-211USA

XP95AMountingBaseAll detectors in the Discovery UL range fit the XP95A Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

• XPERTaddressing

• Onewayfit

• Lockingfeaturetopreventunauthorisedremoval

XP95AMountingBase4” 45681-210USA

XP95AMountingBase6” 45681-225USA

Please check the Apollo website on a regular basis for up-to-date approvals information.

UL 115

DISCOVERY UL

Test Equipment and Maintenance116

Test Equipment & Maintenance

To keep a fire detection system in good working

order, it should be subject to a routine maintenance

programme in accordance with locally applicable

regulations. Over the course of a year, every

detector in the system should be functionally tested

at least once, using recommended equipment.

Apollo offer a range of test equipment, for both

conventional and intelligent systems to enable you

to do this.

Test Equipment and Maintenance 117

TEST EQUIPMENT AND MAINTENANCE

XP95Test Set The XP95 Test Set is a self-contained, portable test unit capable of providing a number of useful functions in relation to individual detectors, ancillary devices or complete circuits of analogue addressable devices in the Apollo intelligent ranges. The main function of the test set is to help the engineer guarantee correct loop configuration before an active control panel is installed.

• User friendly LCD information display

• Speedy commissioning

• Option for hard copy of results

• No unnecessary site visits

• Significant cost reductions

DiscoveryProgrammerThe Discovery Programmer is a portable test and configuration tool for Discovery smoke and heat detectors.

• Look up the date of manufacture

• Check the drift compensation value

• Display and change the operating mode

• Select/de-select LED flash mode

• Tests detectors

• Reads approval codes

XP95TestSet 55000-870EUR

DiscoveryProgrammer 53832-030

Accessories:

ConventionalTestSetThe Conventional Test Set is an invaluable tool designed to give a thorough on-site check of conventional fire detectors within the Apollo Series 65 and AlarmSense range. Each Test Set is supplied with a link head, mains adaptor and carrying case with shoulder strap.

• Easy to use

• 2 button select/accept options

• LCD for clear display

ConventionalTestSet 53832-020

FlameSensorTestUnitandCaseThe Flame Sensor Test Kit is a tool which is designed to test flame detectors without the need of real flames.

• Mimics the characteristics of real flames

FlameSensorTestUnitandCase 29600-226

ProductName PartNumber

Printer for XP95 Test Set 55000-872

Please check the Apollo website on a regular basis for up-to-date approvals information.

Test Equipment and Maintenance118

TEST EQUIPMENT AND MAINTENANCE

Inadditiontothemaintestkits,Apolloprovidearangeofequipmenttoenableyoutokeepyoursystemingoodworkingorder.

AerosolTestGas29600-225

COTestGas29600-235

TelescopicPole,1.26mto4.5m29600-104

ExtensionPole,1.13m29600-103

ProductName PartNumber

FORINSTALLATIONANDREMOVALOFDETECTORS:

Detector Extract Tool 29600-102

Extension Pole, 1.13m 29600-103

Telescopic Pole, 1.26m to 4.5m 29600-104

1.5mm Hexagonal Driver (locks detectors to bases) 29600-095

XPERT Card Insertion Tool 45681-235

FORINSITUFUNCTIONALTESTINGOFINDIVIDUALDETECTORS:

Solo

Smoke Dispenser Head 29600-100

Aerosol Test Gas 29600-225

Heat Detector Test Pole (240V) 29600-229

Heat Detector Test Pole (110V) 29600-231

Cordless Heat Tester Kit 29600-212

Cordless Heat Detector Tester 29600-213

CO Test Gas 29600-235

Detector Duster 29600-449

Battery Batons 29600-183

Battery Charger* 29600-214

Testifire

Smoke/Heat Unit 29600-459

Smoke/Heat Kit 29600-460

Smoke/Heat/CO Unit 29600-461

Smoke/Heat/CO Kit 29600-462

6-Pack Replacement Smoke Capsule 29600-463

3-Pack Replacement Smoke Capsule 29600-464

6-Pack Replacement CO Capsule 29600-465

3-Pack Replacement CO Capsule 29600-466

Battery Batons 29600-183

Battery Charger* 29600-214

Please check the Apollo website on a regular basis for up-to-date approvals information.

*When ordering please state if you require an EU lead or UK lead.

Test Equipment and Maintenance 119

TEST EQUIPMENT AND MAINTENANCE

Additional Services120

Additional Services

Additional Services 121

LoopCalculator

The Apollo Loop Calculator is a free computer programme used

to establish the viability of a design. It enables engineers to

calculate the total loop loading in a proposed Discovery or XP95

fire detection system by inputting relevant variables, for example

control equipment, loop devices and cable length and type.

Parameters are included for Apollo protocol compatible panels.

Please see the Apollo website for more details

www.apollo-fire.co.uk/loop-calc

SimSystem

SimSystem is a tool for simulating loops of detectors and

interfaces in order to demonstrate a system and prove the

design without having to connect actual products to a control

panel. SimSystem consists of a software programme which

features an intuitive graphical display and an interface which

runs up to four loops. A maximum of two interfaces can be

connected, thus allowing a system of up to eight loops to be

simulated.

Training

Apollo offers a series of free one-day training courses for its

customers. The courses cover the following modules:

Module1: DetectionPrinciples&DeviceSelection

Module1.1: CarbonMonoxideFireDetection(Comingsoon)

Module2: ConventionalDetectorOperation

Module2.1: AlarmSense

Module2.2: Orbis(Comingsoon)

Module3: AnalogueAddressablePrinciples

Module3.1: XP95

Module3.2: Discovery

Module3.3: XPlorer

Module3.4: AVAlarmDevices(Comingsoon)

Module3.5: XPander

Module4: IntrinsicallySafeEquipment(Comingsoon)

Module5: Service,Test&Maintenance

In addition to the standard training courses, Apollo can offer

tailor-made courses if required. The majority of courses are held

at Apollo’s head office, but on-site training is also available.

You can find out more about Apollo’s training days and book your

place by visitingwww.apollo-fire.co.uk/training

Approvals122

ApolloFireDetectorshasalibrarythatcontains

hundredsofdifferenttypesofproductcertificate

thathavebeenobtainedfrommanydifferent

nationalandinternationalbodies.Listedbelowis

asmallselection.Pleaseseeourwebsiteformore

detailsandup-to-dateapprovalsinformation.

LossPreventionCertificationBoard(LPCB)TheLPCBisaninternationalcertificationbodywhospecialisesinthefieldsofsecurityandfireprotection.LPCBapprovalisrecognisedbygovernmentsandregulatoryauthoritiesworldwide,particularlyinEurope,theAsia-PacificandtheMiddleEast.TheLPCBapprovalprocessinvolvestheassessmentandtestingofproductstoensurethattheymeetqualitystandardssetbyateamofindustryexperts.Testingiscarriedoutin-housebyLPCBandtheapprovalismaintainedbyregularauditstoensurethattheproductcontinuestomeettheapprovalcriteria.

ApolloproductswithLPCBapproval:

OrbisClass A1R Heat Detector ORB-HT-11001-APO

Class A1R Heat Detector with flashing LED ORB-HT 11013-APO

Class A1S Heat Detector ORB-HT-11166-APO

Class A1S Heat Detector with flashing LED ORB-HT-11167-APO

Class A2S Heat Detector ORB-HT-11002-APO

Class A2S Heat Detector with flashing LED ORB-HT-11014-APO

Class BR Heat Detector ORB-HT-11003-APO

Class BR Heat Detector with flashing LED ORB-HT-11015-APO

Class BS Heat Detector ORB-HT-11004-APO

Class BS Heat Detector with flashing LED ORB-HT-11016-APO

Class CR Heat Detector ORB-HT-11005-APO

Class CR Heat Detector with flashing LED ORB-HT-11017-APO

Class CS Heat Detector ORB-HT-11006-APO

Class CS Heat Detector with flashing LED ORB-HT-11018-APO

Optical Smoke Detector ORB-OP-12001-APO

Optical Smoke Detector with flashing LED ORB-OP-12003-APO

Multisensor Smoke Detector ORB-OH-13001-APO

Multisensor Smoke Detector ORB-OH-13003-APOwith flashing LED

TimeSaver Base ORB-MB-00001-APO

TimeSaver Base LX ORB-MB-00002-APO

TimeSaver Relay Base ORB-RB-10004-APO

TimeSaver Deep Base ORB-MB-00019-APO

OrbisIS Class A1R Heat Detector ORB-HT-51145-APO

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO

Class A1S Heat Detector ORB-HT-51147-APO

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO

Class A2S Heat Detector ORB-HT-51157-APO

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO

Class BR Heat Detector ORB-HT-51149-APO

Class BR Heat Detector with flashing LED ORB-HT-51150-APO

Class BS Heat Detector ORB-HT-51151-APO

Class BS Heat Detector with flashing LED ORB-HT-51152-APO

Class CR Heat Detector ORB-HT-51153-APO

Class CR Heat Detector with flashing LED ORB-HT-51154-APO

Class CS Heat Detector ORB-HT-51155-APO

Class CS Heat Detector with flashing LED ORB-HT-51156-APO

Multisensor Detector ORB-OH-53027-APO

Multisensor Detector with flashing LED ORB-OH-53028-APO

Optical Smoke Detector ORB-OP-52027-APO

Optical Smoke Detector with flashing LED ORB-OP-52028-APO

Adaptor ORB-BA-10008-APO

TimeSaver Base ORB-MB-50018-APO

Series65Class A1R Heat Detector with 55000-120 flashing LED and magnetic test switch

Class A1R Heat Detector with flashing LED 55000-121

Class A1R Heat Detector 55000-122

Class BR Heat Detector with 55000-125flashing LED and magnetic test switch

Class BR Heat Detector with flashing LED 55000-126

Class BR Heat Detector 55000-127

Class CR Heat Detector with 55000-130flashing LED and magnetic test switch

Class CR Heat Detector with flashing LED 55000-131

Class CR Heat Detector 55000-132

Class CS Heat Detector with 55000-135 flashing LED and magnetic test switch

Class CS Heat Detector with flashing LED 55000-136

Class CS Heat Detector 55000-137

Integrating Ionisation Smoke Detector 55000-218 with flashing LED and magnetic test switch

Apollo Fire Detectors has a library that contains

Approvals

Approvals 123

Integrating Ionisation Smoke Detector 55000-219 with flashing LED

Integrating Ionisation Smoke Detector 55000-220

Ionisation Smoke Detector with 55000-215 flashing LED and magnetic test switch

Ionisation Smoke Detector with flashing LED 55000-216

Ionisation Smoke Detector 55000-217

Optical Smoke Detector with 55000-315flashing LED and magnetic test switch

Optical Smoke Detector with flashing LED 55000-316

Optical Smoke Detector 55000-317

Standard Base 45681-200

Diode Base 45681-201

Standard Relay Base 45681-245

Auxiliary Contacts Base 45681-246

Relay 12V EOL Base 45681-247

Relay 24V EOL Base 45681-248

XP95Class CS Heat Detector 55000-401

Class A2S Heat Detector 55000-400

Ionisation Smoke Detector 55000-500

Optical Smoke Detector 55000-600

Multisensor Detector 55000-885

Mounting Base 45681-210

20D Isolating Base 45681-284

Low Power Relay Base 45681-242

Manual Call Point (Surface) 55100-905

Manual Call Point with Isolator (Surface) 55100-908

Isolator Base 45681-211

XP95Interfaces Three Channel Input/Output Unit 55000-588

Switch Monitor Plus 55000-841

Switch Monitor 55000-843

Zone Monitor 55000-845

Input/Output Unit 55000-847

Output Unit 55000-849

Sounder Control Unit 55000-852

XP95IS Class A2S Heat Detector 55000-440

Ionisation Smoke Detector 55000-540

Optical Smoke Detector 55000-640

Standard Manual Call Point 55100-940

Standard Base 45681-215

Discovery Heat Detector - Variable Temperature 58000-400

Ionisation Smoke Detector 58000-500

Optical Smoke Detector 58000-600

Multisensor Detector 58000-700

Mounting Base 45681-210

20D Isolating Base 45681-284

Manual Call Point (Surface) 58100-908

Manual Call Point (Surface) 58100-910

VdSVdSisaninternationalandindependenttestingandcertificationbodybasedinGermanywhospecialisesinthefieldsoffirepreventionandsecurity.Withover100yearsexperience,VdSinspectsandcertifiesproductstoensurethey meetstandardsjointlyestablishedbyVdSandindustryexperts. ApolloproductswithVdSapproval:

Orbis Class A1R Heat Detector ORB-HT-11001-APO

Class A1S Heat Detector ORB-HT-11166-APO

Class A2S Heat Detector ORB-HT-11002-APO

Class BR Heat Detector ORB-HT-11003-APO

Class BS Heat Detector ORB-HT-11004-APO

Class CR Heat Detector ORB-HT-11005-APO

Class CS Heat Detector ORB-HT-11006-APO

Optical Smoke Detector ORB-OP-12001-APO

Multisensor Smoke Detector ORB-OH-13001-APO

TimeSaver Base ORB-MB-00001-APO

TimeSaver LX Base ORB-MB-00002-APO

TimeSaver Diode Base ORB-DB-00003-APO

TimeSaver Relay Base ORB-RB-10004-APO

OrbisIS

Class A1R Heat Detector ORB-HT-51145-APO

Class A1S Heat Detector ORB-HT-51147-APO

Class A2S Heat Detector ORB-HT-51157-APO

Class BR Heat Detector ORB-HT-51149-APO

Class BS Heat Detector ORB-HT-51151-APO

Class CR Heat Detector ORB-HT-51153-APO

Class CS Heat Detector ORB-HT-51155-APO

Multisensor Detector ORB-OH-53027-APO

Optical Smoke Detector ORB-OP-52027-APO

Adaptor ORB-BA-10008-APO

TimeSaver Base ORB-MB-50018-APO

Series65 Class A1R Heat Detector 55000-122

Class BR Heat Detector 55000-127

Class CR Heat Detector 55000-132

Class CS Heat Detector 55000-137

Ionisation Smoke Detector 55000-217

Integrating Ionisation Smoke Detector 55000-220

Optical Smoke Detector 55000-317

Standard Base 45681-200

Standard Relay Base 45681-245

Auxiliary Contacts Base 45681-246

Relay Base - 12V EOL 45681-247

Relay Base - 24V EOL 45681-248

XP95 XP95 Heat Detector 55000-420

Ionisation Smoke Detector 55000-520

Optical Smoke Detector 55000-620

Approvals124

Multisensor Detector 55000-885

20D Positive Short Circuit Isolator 55000-710

20D Negative Short Circuit Isolator 55000-720

Isolator Base 45681-211

Interfaces Three Channel Input/Output Unit 55000-588

Switch Monitor Plus 55000-841

Switch Monitor 55000-843

Zone Monitor 55000-845

Input/Output Unit 55000-847

Output Unit 55000-849

Sounder Control Unit 55000-852

SoundersIntegrated Base Sounder DIN tone 45681-300

Sounder Beacon Base 45681-334

Discovery Variable Temperature Heat Detector 58000-400

Ionisation Smoke Detector 58000-500

Optical Smoke Detector 58000-600

Multisensor Detector 58000-700

Mounting Base 45681-210

ULUnderwritersLaboratories(UL)isanindependentproductcertificationbodybasedintheUnitedStates.ULtestproductsagainststandardssetbyateamofindustryexpertsandpotentialcustomers.TherearenolawswhichspecifythataULmarkmustbeusedonaproduct,however,intheUStherearemanymunicipalitiesthathavelaws,codes orregulationswhichrequireaproducttobetestedbyarecognisedtestinglaboratorysuchasULbeforeitcanbesoldintheirarea.

ApolloproductswithULapproval:

Series65AHeat Detector 135°F - flashing LED 55000-138and magnetic test switch

Heat Detector 135°F - flashing LED 55000-139

Heat Detector 135°F - Standard 55000-140

Heat Detector 170°F - flashing LED 55000-141 and magnetic test switch

Heat Detector 170°F - flashing LED/ 55000-142

Heat Detector 170°F - Standard 55000-143

Heat Detector 200°F - flashing LED 55000-144 and magnetic test switch

Heat Detector 200°F - flashing LED 55000-145

Heat Detector 200°F - Standard 55000-146

Ionization Smoke Detector - flashing LED 55000-225 and magnetic test switch

Ionization Smoke Detector with flashing LED 55000-226

Ionization Smoke Detector - Standard 55000-227

Photo-Electric Smoke Detector flashing LED 55000-325and magnetic test switch

Photo-Electric Smoke Detector 55000-326 with flashing LED

Photo-Electric Smoke Detector - Standard 55000-327

Standard Base 4” 45681-200

Standard Base 6” 45681-220

Low Profile Base 6” 45681-232

E-Z Fit Base 45681-251

4” Conventional Standard Relay Base 45681-255

4” Conventional Auxiliary Contact Base 45681-256

4” Conventional Relay 12V EOL Base 45681-257

4” Conventional Relay 24V EOL Base 45681-258

XP95A Beam Detector 55000-266

High Temperature Heat Detector 55000-450

Ionization Smoke Detector 55000-550

Photo-Electric Smoke Detector 55000-650

Multisensor Detector 55000-886

Negative Isolator 55000-750

4” Addressable Base 45681-210

Isolator Base 45681-211

6” Addressable Base 45681-225

6” Addressable Low Profile Relay Base 45681-242

6” Addressable E-Z Fit Base 45681-250

20D Negative Isolating Base 45681-321

XP95AInterfaces Dual Switch Monitor 55000-790

Switch Monitor 55000-805

Priority Switch Monitor 55000-806

Switch Monitor Input/Output Unit 55000-820

Sounder Control Unit 55000-825

Mini Priority Switch Monitor 55000-830

Mini Switch Monitor 55000-831

Relay Output Module 55000-863

DiscoveryVariable Temperature Heat Detector 58000-450

Ionization Smoke Detector 58000-550

Photo-Electric Smoke Detector 58000-650

Multisensor Detector 58000-750

ULC(UnderwritersLaboratoryofCanada)ULCisanindependentproductcertificationbodythatundertakesthequarterlyinspectionofmanufacturerstoensurecontinuedcomplianceofULListed/RecognisedproductstoAgencyreportsandsafetystandards.ThisworkisdoneundercontracttoULInc(Follow-upServicesDivision).TheyarenotabranchorsubsidiaryofUL.

ApolloproductswithULCapproval:

XP95AIonization Smoke Detector 55000-555

Photo-Electric Smoke Detector 55000-650

Heat Detector 55000-450

Approvals 125

Isolator 55000-750

Multisensor Detector 55000-886

Mounting Base 4” 45681-210USA

Isolator Base 45681-211

Mounting Base 6” 45681-225USA

Low Power Relay Base 4” 45681-242

E-Z Fit Base 45681-250

Isolating Base 45681-321

XP95AInterfacesMini Priority Switch Monitor Module 55000-830

Mini Switch Monitor Module 55000-831

Switch Monitor Module 55000-805

Priority Switch Monitor Module 55000-806

Switch Monitor Input/Output Module 55000-820

Sounder Control Module 55000-825

Relay Output Module 55000-863

Series65APhoto-Electric Smoke Detector Standard 55000-327

Photo-Electric Smoke Detector with 55000-326flashing LED

Photo-Electric Smoke Detector with 55000-325flashing LED and magnetic test switch

135°F Heat Detector Standard 55000-140

135°F Heat Detector with flashing LED 55000-139

135°F Heat Detector with flashing LED 55000-138

and magnetic test switch

170°F Heat Detector Standard 55000-143

170°F Heat Detector with flashing LED 55000-142

170°F Heat Detector with flashing LED 55000-141

and magnetic test switch

200°F Heat Detector Standard 55000-146

200°F Heat Detector with flashing LED 55000-145

200°F Heat Detector with flashing LED 55000-144 and magnetic test switch

Standard Relay Base 4” 45681-255

Auxiliary Relay Base 4” 45681-256

12V End-of-Line Relay Base 4” 45681-257

24V End-of-Line Relay Base 4” 45681-258

E-Z Fit Base 6” 45681-251

DiscoveryULPhoto-Electric Smoke Detector 58000-650

Heat Detector 58000-450

Multisensor Detector 58000-750

Mounting Base 4” 45681-210USA

Mounting Base 6” 45681-225USA

E-Z Fit Base 45681-250

FMFMApprovalscertifiesproductsandserviceswithauniquefocusonobjectivelytestingpropertylosspreventionproductsandservicesandcertifyingthosethatmeetrigorouslosspreventionstandards.

ApolloproductswithFMapproval:

XP95AIonization Smoke Detector 55000-550

Photo-Electric Smoke Detector 55000-650

Heat Detector 55000-450

Mounting Base 4” 45681-210USA

Mounting Base 6” 45681-225USA

Isolator 55000-750

DiscoveryULMounting Base 4” 45681-210USA

Mounting Base 6” 45681-225USA

Isolator 55000-750

CCCFFireProductTypeApprovalorCCCFApprovalisacompulsorycertificationforfireproductsenteringtheChinamarket.

ApolloproductswithCCCFapproval:

XP95Grade 2 Heat Detector 55000-420

Ionisation Smoke Detector 55000-520

Optical Smoke Detector 55000-620

Surface Mount Manual Call Point 55000-905

Flush Mount Manual Call Point 55000-906

DiscoveryDiscovery Heat Detector 58000-400MAC

Discovery Ionisation Smoke Detector 58000-500MAC

Discovery Optical Smoke Detector 58000-600MAC

Discovery Multisensor Detector 58000-700MAC

Discovery UL Heat Detector 58000-450

Discovery UL Ionization Smoke Detector 58000-550

Discovery UL Photo-Electric Smoke Detector 58000-650

Discovery UL Multisensor Detector 58000-750

Discovery Manual call Point with Isolator 58100-908Red (Surface)

Discovery Manual Call Point - Red (Surface) 58100-910

Orbis Orbis Optical Smoke Detector with ORB-OP-12003-PRCflashing LED

Orbis Multisensor with flashing LED ORB-OH-13003-PRC

Orbis A1R Heat Detector with flashing LED ORB-HT-11013-PRC

Orbis A2S Heat Detector with flashing LED ORB-HT-11014-PRC

Orbis BR Heat Detector with flashing LED ORB-HT-11015-PRC

Orbis BS Heat Detector with flashing LED ORB-HT-11016-PRC

Orbis CR Heat Detector with flashing LED ORB-HT-11017-PRC

Orbis CS Heat Detector with flashing LED ORB-HT-11018-PRC

Orbis Marine Optical Smoke Detector ORB-OP-42003-MACwith flashing LED

Orbis Marine Multisensor Detector ORB-OH-43003-MACwith flashing LED

Orbis Marine A1R Heat Detector with flashing LED ORB-HT-41013-MAC

Approvals126

Orbis Marine A2S Heat Detector with flashing LED ORB-HT-41014-MAC

Orbis Marine BR Heat Detector with flashing LED ORB-HT-41015-MAC

Orbis Marine BS Heat Detector with flashing LED ORB-HT-41016-MAC

Orbis Marine CR Heat Detector with flashing LED ORB-HT-41017-MAC

Orbis Marine CS Heat Detector with flashing LED ORB-HT-41018-MAC

XP95 XP95 Waterproof Manual Call Point 55000-950

OrbisISDetectors Orbis IS A1R Heat Detector with flashing LED ORB-HT-51146-PRC

Orbis IS A2S Heat Detector with flashing LED ORB-HT-51148-PRC

Orbis IS BR Heat Detector with flashing LED ORB-HT-51150-PRC

Orbis IS BS Heat Detector with flashing LED ORB-HT-51152-PRC

Orbis IS CR Heat Detector with flashing LED ORB-HT-51154-PRC

Orbis IS CS Heat Detector with flashing LED ORB-HT-51156-PRC

Orbis IS Optical Smoke Detector with flashing LED ORB-OP-52028-PRC

Orbis IS Multisensor with flashing LED ORB-OH-53028-PRC

XP95IS XP95 IS Heat Detector 55000-440

XP95 IS Ionisation Smoke Ddetector 55000-540

XP95 IS Optical Smoke Detector 55000-640

XP95 IS Manual Call Point without flap - red 55000-940

XP95 IS Manual Call Point MEDC 58100-970Push Button -red

XP95 IS Manual Call Point MEDC 58100-971Push Button - yellow

ConstructionProductsDirective(CPD)TheCPDisoneofthe‘NewApproach’DirectivestocreateasingleEuropeanmarketbyremovingtechnicalbarrierstotradebetweenMemberStates.ProductswhichmeettheessentialrequirementsoftherelevantdirectiveswillbeeligibleforCEmarkingandmaybeplacedonthemarketanywherewithintheEEA.

ApolloproductswithCPDapproval:

AlarmSense Integrating Optical Detector 55000-391

Heat Detector A1R 55000-190

Heat Detector CS 55000-193

Base 45681-244

Sounder Base LR 45681-341

Sounder Base 45681-510

Sounder Beacon Base LR 45681-509

Sounder Beacon Base 45681-509

Manual Call Point (Surface) 55000-894

Series65Class A1R Heat Detector with 55000-120 flashing LED and magnetic test switch

Class A1R Heat Detector with flashing LED 55000-121

Class A1R Heat Detector 55000-122

Class BR Heat Detector with 55000-125 flashing LED and magnetic test switch

Class BR Heat Detector with flashing LED 55000-126

Class BR Heat Detector 55000-127

Class CR Heat Detector with 55000-130flashing LED and magnetic test switch

Class CR Heat Detector with flashing LED 55000-131

Class CR Heat Detector 55000-132

Class CS Heat Detector with 55000-135 flashing LED and magnetic test switch

Class CS Heat Detector with flashing LED 55000-136

Class CS Heat Detector 55000-137

French Ionisation Smoke Detector 55000-208

French Optical Smoke Detector 55000-308

Ionisation Smoke Detector with 55000-215flashing LED and magnetic test switch

Ionisation Smoke Detector with flashing LED 55000-216

Ionisation Smoke Detector 55000-217

Integrating Ionisation Smoke Detector 55000-218 with flashing LED and magnetic test switch

Integrating Ionisation Smoke Detector 55000-219 with flashing LED

Integrating Ionisation Smoke Detector 55000-220

Optical Smoke Detector with 55000-315 flashing LED and magnetic test switch

Optical Smoke Detector with flashing LED 55000-316

Optical Smoke Detector 55000-317

Standard Base 45681-200

Standard Relay Base 45681-245

Auxiliary Relay Base 45681-246

Relay 12V EOL Base 45681-247

Relay 24V EOL Base 45681-248

OrbisClass A1R Heat Detector ORB-HT-11001-APO

Class A1R Heat Detector with flashing LED ORB-HT 11013-APO

Class A1S Heat Detector ORB-HT-11166-APO

Class A1S Heat Detector with flashing LED ORB-HT-11167-APO

Class A2S Heat Detector ORB-HT-11002-APO

Class A2S Heat Detector with flashing LED ORB-HT-11014-APO

Class BR Heat Detector ORB-HT-11003-APO

Class BR Heat Detector with flashing LED ORB-HT-11015-APO

Class BS Heat Detector ORB-HT-11004-APO

Class BS Heat Detector with flashing LED ORB-HT-11016-APO

Class CR Heat Detector ORB-HT-11005-APO

Class CR Heat Detector with flashing LED ORB-HT-11017-APO

Class CS Heat Detector ORB-HT-11006-APO

Class CS Heat Detector with flashing LED ORB-HT-11018-APO

Optical Smoke Detector ORB-OP-12001-APO

Optical Smoke Detector with flashing LED ORB-OP-12003-APO

Multisensor Smoke Detector ORB-OH-13001-APO

Multisensor Smoke Detector ORB-OH-13003-APOwith flashing LED

TimeSaver Base ORB-MB-00001-APO

TimeSaver Base LX ORB-MB-00002-APO

TimeSaver Deep Base ORB-MB-00019-APO

Approvals 127

OrbisISClass A1R Heat Detector ORB-HT-51145-APO

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO

Class A1S Heat Detector ORB-HT-51157-APO

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO

Class A2S Heat Detector ORB-HT-51147-APO

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO

Class BR Heat Detector ORB-HT-51149-APO

Class BR Heat Detector with flashing LED ORB-HT-51150-APO

Class BS Heat Detector ORB-HT-51151-APO

Class BS Heat Detector with flashing LED ORB-HT-51152-APO

Class CR Heat Detector ORB-HT-51153-APO

Class CR Heat Detector with flashing LED ORB-HT-51154-APO

Class CS Heat Detector ORB-HT-51155-APO

Class CS Heat Detector with flashing LED ORB-HT-51156-APO

Multisensor Detector ORB-OH-53027-APO

Multisensor Detector with flashing LED ORB-OH-53028-APO

Optical Smoke Detector ORB-OP-52027-APO

Optical Smoke Detector with flashing LED ORB-OP-52028-APO

Adaptor ORB-BA-10008-APO

TimeSaver Base ORB-MB-50018-APO

XP95 Class A2S Heat Detector 55000-400

Class CS Heat Detector 55000-401

Ionisation Smoke Detector 55000-500

Optical Smoke Detector 55000-600

Multisensor Smoke Detector 55000-885 Mounting Base 45681-210Isolating Base 45681-284

XP95Interfaces Three Channel Input/Output Unit 55000-588

Switch Monitor Plus 55000-841

Switch Monitor 55000-843

Zone Monitor 55000-845

Input/Output Unit 55000-847

Output Unit 55000-849

Sounder Control Unit 55000-852

XP95ISClass A2S Heat Detector 55000-440

Ionisation Smoke Detector 55000-540

Optical Smoke Detector 55000-640

Base 55000-215

Manual Call Point (Red) 55000-940

DiscoveryHeat Detector 58000-400

Ionisation Smoke Detector 58000-500

Isolating Base 45681-284

Optical Smoke Detector 58000-600

Multisensor Detector 58000-700

Mounting Base 45681-210

BaseSoundersIntegrated Base Sounder with Isolator 45681-277

Integrated Base Sounder 45681-278

Slow Whoop Integrated Base Sounder 45681-290 with Isolator

Slow Whoop Integrated Base Sounder 45681-291

Integrated Base Sounder with 45681-300Short Circuit Isolator (DIN tone)

Intelligent Base Sounder 45681-265

Intelligent Base Sounder for Isolating Base 45681-266

Intelligent Base Sounder Slow Whoop 45681-267

Intelligent Base Sounder Slow Whoop 45681-268for Isolating Base

Series 65 Sounder Base 45681-512

Series 65 Sounder Base with Diode 45681-513

SounderBeaconMulti-Tone Open Area Sounder Beacon Red 55000-291

Sounder Beacon Base with Isolator 45681-330

Sounder Beacon Base 45681-331

Slow Whoop Sounder Beacon Base 45681-332 with Isolator

Sounder Beacon Base 45681-334 with Isolator (DIN Tone)

Sounders100dB(A) Loop-Powered Sounder Red 55000-278

100dB(A) Loop-Powered Sounder White 55000-279

100dB(A) Loop-Powered Sounder 55000-276Slow Whoop Red

100dB(A) Loop-Powered Sounder 55000-277Slow Whoop White

Weatherproof 100dB(A) Sounder Red 55000-274

Weatherproof 100dB(A) Sounder White 55000-275

XPanderXPander Optical Smoke Detector andMounting Base XPA-CB-12034-APO

XPander Multisensor Detector and Mounting Base XPA-CB-13032-APO

XPander A1R Heat Detector and Mounting Base XPA-CB-11170-APO

XPander CS Heat Detector and Mounting Base XPA-CB-11171-APO

XPander Manual Call Point XPA-MC-14006-APO

XPander Sounder and Sounder Base Red XPA-CB-14001-APO

XPander Sounder and Sounder Base White XPA-CB-14002-APO

XPander Sounder Beacon and Sounder Base Red XPA-CB-14003-APO

XPander Sounder Beacon Amber andSounder Base White XPA-CB-14004-APO

XPander Sounder Beacon and SounderBase White XPA-CB-14005-APO

Approvals128

ATEXTheATEXdirectiveiscompulsoryforallequipmentwhichisusedinahazardousarea(whereanexplosiveatmospheremightoccur).ThenameATEXcomesfromtheFrenchATmospheresEXplosibles.

ApolloproductswithATEXapproval:

XP95ISIonisation Detector 55000-540

Optical Smoke Detector 55000-640

Heat Detector 55000-440

Base 45681-215

IS Standard Manual Call Points 55000-940/942/ 944

IS MEDC Manual Call Points 55000-960/962/ 964/966/961/963/ 965/967

OrbisIS Class A1R Heat Detector ORB-HT-51145-APO

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO

Class A1S Heat Detector ORB-HT-51157-APO

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO

Class A2S Heat Detector ORB-HT-51147-APO

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO

Class BR Heat Detector ORB-HT-51149-APO

Class BR Heat Detector with flashing LED ORB-HT-51150-APO

Class BS Heat Detector ORB-HT-51151-APO

Class BS Heat Detector with flashing LED ORB-HT-51152-APO

Class CR Heat Detector ORB-HT-51153-APO

Class CR Heat Detector with flashing LED ORB-HT-51154-APO

Class CS Heat Detector ORB-HT-51155-APO

Class CS Heat Detector with flashing LED ORB-HT-51156-APO

Multisensor Detector ORB-OH-53027-APO

Multisensor Detector with flashing LED ORB-OH-53028-APO

Optical Smoke Detector ORB-OP-52027-APO

Optical Smoke Detector with flashing LED ORB-OP-52028-APO

TimeSaver Base ORB-MB-50018-APO

Index: Sequential Part Number List 129

IndexSequential Part

Number List

45681-215 XP95 IS Mounting Base .................................................96

45681-217 Polycarbonate Deckhead Mounting Box ...................................................................12,19, 28, 84

45681-219 Intelligent Heater Base .......................................... 12, 19

45681-220USA Series 65A 6” Standard Base..................................110

45681-225USA XP95A 6” Mounting Base ................................ 105,114

45681-232 Series 65A 6” Low Profile Base ..............................110

45681-233 Backplate ............................................................................83

45681-235 XPERT Card Insertion Tool ........................................118

45681-238 Series 90 to XP95 Base Adaptor ...............................85

45681-242 Intelligent Low Power Relay Base .................... 12, 19

45681-242UL XP95A 4” Low Power Relay Base .........................105

45681-244 AlarmSense Base ............................................................37

45681-245 Series 65 Standard Relay Base .................................32

45681-246 Series 65 Auxiliary Relay Base ..................................32

45681-247 Series 65 End-of-Line Relay Base (12V).................32

45681-248 Series 65 End-of-Line Relay Base (24V).................32

45681-250 E-Z Fit Base ............................................................. 105,114

45681-251 Series 65A 6” E-Z Fit Base .........................................111

45681-255 Series 65A 4” Standard Relay Base ......................110

45681-256 Series 65A 4” Auxiliary Relay Base .......................110

45681-257 Series 65A 4” 12V End-of-Line Relay Base ........110

45681-258 Series 65A 4” 24V End-of-Line Relay Base ........110

45681-265 Intelligent Base Sounder .............................................56

45681-266 Intelligent Base Sounder for Isolating Base ...........56

45681-267 Intelligent Base Sounder Slow Whoop ..................56

45681-268 Intelligent Base Sounder Slow Whoop for Isolating Base .............................................................56

45681-276 Ancillary Base Sounder ..................................................56

45681-277 Integrated Base Sounder with Isolator ...................56

45681-278 Integrated Base Sounder ..............................................56

45681-284 Isolating Base ..............................................................11,18

45681-290 Integrated Base Sounder - Slow Whoop with Isolator .......................................................................56

26729-152 Transparent Hinged Cover for Manual Call Point .............................................................79

27249-005 Deckhead Adaptor PG16-M20 ...................................84

29600-095 1.5mm Hexagonal Driver .............................................85

29600-098 IS Galvanic Barrier ............................................................97

29600-100 Smoke Dispenser Head ...........................................118

29600-101 Heat Detector Test Pole (240V) .............................118

29600-102 Detector Extract Tool .................................................118

29600-103 Extension Pole, 1.13m ..............................................118

29600-104 Telescopic Pole, 1.26m to 4.5m ............................118

29600-110 Heat Detector Test Pole (110V) ............................118

29600-131 Metal Deckhead Mounting Box (PG16) .................84

29600-139 Metal Deckhead Mounting Box (M20)...................84

29600-183 Battery Batons .............................................................118

29600-203 Flame Detector Bracket ................................................47

29600-206 Flame Detector Weathershield ..................................47

29600-212 Cordless Heat Tester Kit ...........................................118

29600-213 Cordless Heat Detector Tester ...............................118

29600-214 Battery Charger .............................................................118

29600-225 Aerosol Test Gas .........................................................118

29600-226 Flame Sensor Test Unit and Case ..........................117

29600-235 CO Test Gas ....................................................................118

29600-239 DIN-Rail Interface Enclosure (4 units) .............. 77, 85

29600-240 DIN-Rail Interface Enclosure (10 units) ........... 77, 85

29600-241 Reflective Beam Detector Backbox .........................49

29600-256 White Cap ...........................................................................56

29600-257 Red Cap ...............................................................................56

29600-318 Beacon Enclosure .............................................59, 67, 84

29600-350 Firebeam Beam Detector 5-40m .............................49

29600-351 Firebeam Extension Kit 40-80m ................................49

29600-352 Firebeam Extension Kit 80-100m .............................49

29600-353 Firebeam Adaptor Plate ................................................49

29600-378 Galvanic Barier ...............................................................100

29600-449 Detector Duster .............................................................118

29600-458 Base Mounted Flame Detector Bracket .................47

29600-459 Smoke/Heat Unit ..........................................................118

29600-460 Smoke/Heat Kit .............................................................118

29600-461 Smoke/Heat/CO Unit ..................................................118

29600-462 Smoke/Heat/CO Kit.....................................................118

29600-463 6-Pack Replacement Smoke Capsule ..................118

29600-464 3-Pack Replacement Smoke Capsule ..................118

29600-465 6-Pack Replacement CO Capsule ...........................118

29600-466 3-Pack Replacement CO Capsule ...........................118

29650-001 Magnetic Wand ................................................................67

38531-771 Blank XPERT Card .............................................................23

38531-822 Module Base .....................................................................83

45681-200 Series 65 Standard Base ...............................................31

45681-200USA Series 65A 4” Standard Base ...................................110

45681-201 Series 65 Diode Base .....................................................31

45681-204 Conduit Box .......................................................................83

45681-206 Series 65 Sav-Wire Base ..............................................32

45681-209 Intelligent Deep Base ...............................................11,19

45681-210 Intelligent Mounting Base .................................... 11, 18

45681-210USA XP95A 4” Mounting Base ................................ 105,114

45681-210MAR Discovery Marine Mounting Base .............................89

45681-211 Isolator Base .............................................................. 12, 18

45681-211USA XP95A Isolator Base ........................................... 105,114

45681-211MAR Discovery Marine Isolator Base .................................89

Index: Sequential Part Number List 130

45681-291 Integrated Base Sounder - Slow Whoop ...............56

45681-292 White Cap ................................................................... 56, 65

45681-293 Red Cap ....................................................................... 56, 65

45681-294 AlarmSense White Cap ......................................... 57, 65

45681-295 AlarmSense Red Cap ............................................. 57, 65

45681-300 Integrated Base Sounder DIN-Tone with Isolator .56

45681-309 Detector Ceiling Tile Mounting Box ..........................84

45681-310 Sounder Ceiling Tile Mounting Box...........................84

45681-311 Sounder Ceiling Plate .....................................................83

45681-321 Intelligent Isolating Base ....................................... 11, 18

45681-321USA XP95A Isolating Base ......................................... 105,114

45681-330 Sounder Beacon Base with Isolator .........................65

45681-331 Sounder Beacon Base .................................................65

45681-332 Sounder Beacon Base Slow Whoop with Isolator .......................................................................65

45681-333 Loop Powered Beacon Base with Isolator ............61

45681-334 Sounder Beacon Base with Isolator DIN-Tone ....65

45681-335 Loop-Powered Beacon Base Standard Flash .......61

45681-336 Sounder Beacon Base with Australian Tone ........65

45681-337 Loop-Powered Beacon Base with Australian Flash ................................................................61

45681-338 Sounder Beacon Base with NZ Tone .......................65

45681-340 AlarmSense Sounder Beacon Base LR ....................65

45681-341 AlarmSense Sounder Base LR ...................................57

45681-370 Series 65 Base Cover ....................................................83

45681-380 XP95 Base Cover ............................................................83

45681-393 Discovery Sounder Beacon Base ..............................65

45681-508 Series 65 12V Relay Base ............................................32

45681-509 AlarmSense Sounder Beacon Base ........................65

45681-510 AlarmSense Sounder Base ..........................................57

45681-512 Series 65 Sounder Base .............................................57

45681-513 Series 65 Sounder Base with Diode ........................57

45682-127 Pre-Addressed XPERT Cards........................................23

53546-021 Conventional Duct Detector ........................................51

53546-022 Intelligent Duct Detector ...............................................51

53546-023 Orbis Duct Detector ........................................................51

53832-020 Conventional Test Set .................................................117

53832-030 Discovery Programmer ..............................................117

53832-070 MiniDisc Remote Indicator ..............12,19, 28, 33, 37

55000-001 Intelligent Open-Area Sounder Red .........................54

55000-002 Intelligent Open-Area Sounder White .....................54

55000-005 Intelligent Open-Area Sounder Beacon Red.............. Lens .......................................................................................63

55000-006 Intelligent Open-Area Sounder Beacon Clear Lens ...........................................................................63

55000-009 Intelligent Open-Area Beacon Red Lens ...................59

55000-010 Intelligent Open-Area Beacon Clear Lens) ...............59

55000-020 Intelligent IR3 Flame Detector .....................................46

55000-021 Intelligent Flameproof IR3 Flame Detector ............46

55000-022 Intelligent Base Mounted UV Flame Detector .....47

55000-023 Intelligent Base Mounted UV IR² Flame Detector ..47

55000-024 Intelligent Base Mounted IR3 Flame Detector .........47

55000-120 Series 65 A1R Heat Detector flashing LED and magnetic test switch ............................................31

55000-121 Series 65 A1R Heat Detector ....................................31

55000-122 Series 65 A1R Heat Detector Standard ..................31

55000-125 Series 65 BR Heat Detector flashing LED and magnetic test switch ............................................31

55000-126 Series 65 BR Heat Detector flashing LED ...............31

55000-127 Series 65 BR Heat Detector Standard .....................31

55000-130 Series 65 CR Heat Detector flashing LED and magnetic test switch ............................................31

55000-131 Series 65 CR Heat Detector flashing LED ...............31

55000-132 Series 65 CR Heat Detector Standard ......................31

55000-135 Series 65 CS Heat Detector flashing LED and magnetic test switch ............................................31

55000-136 Series 65 CS Heat Detector flashing LED ................31

55000-137 Series 65 CS Heat Detector Standard ......................31

55000-138 Series 65A 135˚F Heat Detector flashing LED and magnetic test switch .........................................109

55000-139 Series 65A 135˚F Heat Detector flashing LED ...109

55000-140 Series 65A 135˚F Heat Detector Standard ..........109

55000-141 Series 65A 170˚F Heat Detector flashing LED and magnetic test switch ........................................109

55000-142 Series 65A 170˚F Heat Detector flashing LED ..109

55000-143 Series 65A 170˚F Heat Detector Standard ........109

55000-144 Series 65A 200˚F Heat Detector flashing LED and magnetic test switch .........................................109

55000-145 Series 65A 200˚F Heat Detector flashing LED ...109

55000-146 Series 65A 200˚F Heat Detector Standard ..........109

55000-182 DIN-Rail Sounder Controller (5 Amperes)..............76

55000-190 AlarmSense A1R Heat Detector (Standard) .........36

55000-193 AlarmSense CS Heat Detector (High Temp) ........36

55000-196 AlarmSense A1R Heat Detector and Sounder Base ....................................................................36

55000-197 AlarmSense CS Heat Detector and Sounder Base ....................................................................36

55000-198 AlarmSense A1R Heat Detector and Sounder Beacon Base ...................................................36

55000-199 AlarmSense CS Heat Detector and Sounder Beacon Base ...................................................36

55000-215 Series 65 Ionisation Smoke Detector flashing LED and magnetic test switch ...................30

55000-216 Series 65 Ionisation Smoke Detector flashing LED ........................................................................30

55000-217 Series 65 Ionisation Smoke Detector Standard ...30

55000-218 Series 65 Integrating Ionisation Smoke Detector flashing LED and magnetic test switch ......30

55000-219 Series 65 Integrating Ionisation Smoke Detector flashing LED .....................................................30

55000-220 Series 65 Integrating Ionisation Smoke Detector ..30

55000-225 Series 65A Ionization Smoke Detector flashing LED and magnetic test switch ................109

55000-226 Series 65A Ionization Smoke Detector flashing LED ..................................................................109

55000-227 Series 65A Ionization Smoke Detector Standard ...........................................................................109

55000-266 XP95A Loop Powered Beam Detector ................104

55000-268 Reflective Beam Detector (5-50m) .........................49

55000-273 Reflective Beam Detector (50-100m) ....................49

55000-274 Intelligent 100dB(A) Weatherproof Sounder Open-Area Red ................................................................54

55000-275 Intelligent 100dB(A) Weatherproof Sounder Open-Area White ............................................................54

55000-276 Intelligent 100dB(A) Open-Area Sounder Slow Whoop Red .............................................................54

55000-277 Intelligent 100dB(A) Open-Area Sounder Slow Whoop White.........................................................54

55000-278 Intelligent 100dB(A) Open-Area Sounder Red ....54

55000-279 Intelligent 100dB(A) Open-Area Sounder White ....................................................................................54

55000-280 Intelligent IR² Flame Detector .....................................46

Index: Sequential Part Number List 131

55000-291 Multi-Tone Open Area Sounder Beacon Red .......63

55000-292 Multi-Tone Open Area Sounder Beacon White ...63

55000-293 Multi-Tone Open Area Sounder Beacon Red with Isolator .......................................................................63

55000-294 Multi-Tone Open Area Sounder Beacon White with Isolator .......................................................................63

55000-295 Flameproof Intelligent IR² Flame Detector ............46

55000-296 Weatherproof Multi-Tone Open Area Sounder Beacon Red ........................................................................63

55000-297 Weatherproof Multi-Tone Open Area Sounder Beacon White ...................................................................63

55000-298 Weatherproof Multi-Tone Open Area Sounder Beacon Red with Isolator .............................................63

55000-299 Weatherproof Multi-Tone Open Area Sounder Beacon White with Isolator .........................................63

55000-315 Series 65 Optical Smoke Detector flashing LED and magnetic test switch ....................................30

55000-316 Series 65 Optical Smoke Detector flashing LED 30

55000-317 Series 65 Optical Smoke Detector Standard ........30

55000-325 Series 65A Photo-Electric Smoke Detector flashing LED and magnetic test switch ................109

55000-326 Series 65A Photo-Electric Smoke Detector flashing LED ..................................................................109

55000-327 Series 65A Photo-Electric Smoke Detector Standard ...........................................................................109

55000-390 AlarmSense Optical Smoke Detector ......................36

55000-391 AlarmSense Integrating Optical Smoke Detector ..............................................................................36

55000-392 AlarmSense Optical Smoke Detector and Sounder Base ....................................................................36

55000-393 AlarmSense Integrating Optical Smoke Detector and Sounder Base ........................................36

55000-394 AlarmSense Optical Smoke Detector and Sounder Beacon Base ...................................................36

55000-395 AlarmSense Integrating Optical Smoke Detector and Sounder Beacon Base ........................36

55000-400 XP95 Heat Detector A2S ..............................................17

55000-401 XP95 Heat Detector CS .................................................17

55000-440 XP95 IS Heat Detector ...................................................96

55000-450 XP95A Heat Detector .................................................104

55000-500 XP95 Ionisation Smoke Detector ..............................17

55000-540 XP95 IS Ionisation Smoke Detector..........................96

55000-550 XP95A Ionization Smoke Detector ........................104

55000-588 Three Channel Input/Output Unit ..............................70

55000-600 XP95 Optical Smoke Detector ....................................17

55000-640 XP95 IS Optical Smoke Detector ...............................96

55000-650 XP95A Photo-Electric Smoke Detector ................104

55000-700MAR Discovery Marine Isolator .............................................89

55000-720 Isolator ...........................................................................11,18

55000-750 XP95A Isolator ..................................................... 105,114

55000-760 Mini Switch Monitor ............................................... 74, 77

55000-765 Mini Monitor Module ..................................................106

55000-790 XP95A Dual Priority Switch Monitor Module .....107

55000-802 DIN-Rail Dual Isolator ......................................................77

55000-803 DIN-Rail Input/Output Unit ...........................................76

55000-804 DIN-Rail Output Unit .......................................................76

55000-805 XP95A Switch Monitor Module ..............................106

55000-806USA XP95A Priority Switch Monitor Module ...............107

55000-812 DIN-Rail Zone Monitor with Isolator .........................77

55000-820USA XP95A Switch Monitor Input/Output Module ...107

55000-821 DIN-Rail Switch Monitor Plus ......................................77

55000-822 DIN-Rail Switch Monitor ................................................76

55000-825 XP95A Sounder Control Module .............................107

55000-826 DIN-Rail Sounder Control Unit .....................................80

55000-830 XP95A Mini Priority Switch Monitor Module .....106

55000-831 XP95A Mini Switch Monitor Module ....................106

55000-832 Mini Switch Monitor with fly leads (Interrupt).....74

55000-833 Mini Switch Monitor with fly leads ...........................74

55000-835 AlarmSense Alarm Relay ............................................37

55000-841 Switch Monitor Plus ........................................................71

55000-843 Switch Monitor .................................................................71

55000-845 Zone Monitor Unit ...........................................................71

55000-847 Input/Output Unit ............................................................70

55000-849 Output Unit .........................................................................70

55000-852 Sounder Control Unit ......................................................70

55000-855 XP95 Protocol Translator (Single Channel) ............97

55000-856 XP95 Protocol Translator (Dual Channel) ...............97

55000-863 XP95A Relay Output Module ...................................107

55000-870 XP95 Test Set .................................................................117

55000-872 Printer for XP95 Test Set ...........................................117

55000-875 Mains Switching Input/Output Unit ..........................71

55000-877 Loop-Powered Beacon Red ........................................59

55000-878 Loop-Powered Beacon Clear Lens Red Flash .......59

55000-879 Loop-Powered Beacon Amber ..................................59

55000-885 XP95 Multisensor Detector ..........................................17

55000-886 XP95A Multisensor Detector ...................................104

55000-894 AlarmSense Manual Call Point (Surface) ...............80

55100-940 XP95 IS Manual Call Point Without Flap - Red ......96

55100-942 XP95 IS Manual Call Point Without Flap - Yellow ..96

55100-944 XP95 IS Manual Call Point Without Flap - Blue/White .........................................................................96

55000-945 XP95 IS Manual Call Point With Flap - Blue/White .........................................................................96

55000-960 XP95 IS Manual Call Point MEDC Break Glass - Red .........................................................................97

55000-961 XP95 IS Manual Call Point MEDC Break Glass with flap - Red ......................................................97

55000-962 XP95 IS Manual Call Point MEDC Break Glass - Yellow ...................................................................97

55000-963 XP95 IS Manual Call Point MEDC Break Glass with flap - Yellow ................................................97

55000-964 XP95 IS Manual Call Point MEDC Break Glass - Blue ........................................................................97

55000-965 XP95 IS Manual Call Point MEDC Break Glass with flap - Blue .....................................................97

55000-966 XP95 IS Manual Call Point MEDC Break Glass - Black/Yellow Stripes ........................................97

55000-967 XP95 IS Manual Call Point MEDC Break Glass with flap - Black/Yellow Stripes ....................97

55000-970 XP95 IS Manual Call Point MEDC Push Button - Red ......................................................................97

55000-971 XP95 IS Manual Call Point MEDC Push Button - Yellow ................................................................97

55000-972 XP95 IS Manual Call Point MEDC Push Button - Blue .....................................................................97

55000-973 XP95 IS Manual Call Point MEDC Push Button - Black/Yellow Stripes.....................................97

55100-905 XP95 Manual Call Point - Red (Surface) .................79

55100-908 XP95 Manual Call Point with Isolator - Red (Surface) .............................................................................79

58000-300 Discovery CO Fire Detector..........................................10

58000-400 Discovery Heat Detector ..............................................10

Index: Sequential Part Number List 132

58000-400MAR Discovery Marine Heat Detector ...............................88

58000-450 Discovery UL Heat Detector ....................................113

58000-500 Discovery Ionisation Smoke Detector .....................10

58000-500MAR Discovery Marine Ionisation Smoke Detector .....88

58000-550 Discovery UL Ionization Smoke Detector ............113

58000-600 Discovery Optical Smoke Detector...........................10

58000-600MAR Discovery Marine Optical Smoke Detector ...........88

58000-650 Discovery UL Photo-Electric Smoke Detector ...113

58000-700 Discovery Multisensor Detector ................................10

58000-700MAR Discovery Marine Multisensor ....................................88

55000-797 DIN-Rail Mains Input/Output Unit .............................76

58000-750 Discovery UL Multisensor Detector .......................113

58100-908 Discovery Manual Call Point with Isolator - Red (Surface) ....................................................................79

58100-910 Discovery Manual Call Point - Red (Surface) ........79

51800-920 Discovery Manual Call Point (non standard) White ...................................................................................79

51800-927 Discovery Manual Call Point (non standard) Yellow ..................................................................................79

58100-928 Discovery Manual Call Point (non standard) Blue .......................................................................................79

58100-929 Discovery Manual Call Point (non standard) Green ...................................................................................79

58100-950 Waterproof Manual Call Point - Red ........................80

58100-951 Waterproof Manual Call Point with Isolator - Red ........................................................................................80

58100-970MAR Discovery Marine Manual Call Point .......................89

ORB-BA-10008-APO S65 to Orbis Base Adaptor ..........................................85

ORB-BA-50008-APO Orbis IS Adaptor ............................................................100

ORB-DB-00003-APO TimeSaver Diode Base ..................................................27

ORB-HB-00020-APO Orbis Heater Base ...........................................................28

ORB-HT-11001-APO Orbis A1R Heat Detector Standard ...........................26

ORB-HT-11002-APO Orbis A2S Heat Detector Standard ...........................26

ORB-HT-11003-APO Orbis BR Heat Detector Standard ..............................26

ORB-HT-11004-APO Orbis BS Heat Detector Standard ..............................26

ORB-HT-11005-APO Orbis CR Heat Detector Standard ..............................26

ORB-HT-11006-APO Orbis CS Heat Detector Standard ..............................26

ORB-HT-11013-APO Orbis A1R Heat Detector with flashing LED ..........26

ORB-HT-11014-APO Orbis A2S Heat Detector with flashing LED ..........26

ORB-HT-11015-APO Orbis BR Heat Detector with flashing LED .............26

ORB-HT-11016-APO Orbis BS Heat Detector with flashing LED .............26

ORB-HT-11017-APO Orbis CR Heat Detector with flashing LED .............26

ORB-HT-11018-APO Orbis CS Heat Detector with flashing LED ..............26

ORB-HT-11166-APO Orbis A1S Heat Detector ..............................................26

ORB-HT-11167-APO Orbis A1S Heat Detector with flashing LED ..........26

ORB-HT-41001-MAR Orbis Marine A1R Heat Detector ...............................91

ORB-HT-41002-MAR Orbis Marine A2S Heat Detector ...............................91

ORB-HT-41003-MAR Orbis Marine BR Heat Detector ..................................91

ORB-HT-41004-MAR Orbis Marine BS Heat Detector ..................................91

ORB-HT-41005-MAR Orbis Marine CR Heat Detector ..................................91

ORB-HT-41006-MAR Orbis Marine CS Heat Detector ..................................91

ORB-HT-41013-MAR Orbis Marine A1R Heat Detector with flashing LED ........................................................................91

ORB-HT-41014-MAR Orbis Marine A2S Heat Detector with flashing LED ........................................................................91

ORB-HT-41015-MAR Orbis Marine BR Heat Detector with flashing LED ........................................................................91

ORB-HT-41016-MAR Orbis Marine BS Heat Detector with flashing LED ........................................................................91

ORB-HT-41017-MAR Orbis Marine CR Heat Detector with flashing LED ........................................................................91

ORB-HT-41018-MAR Orbis Marine CS Heat Detector with flashing LED ........................................................................91

ORB-HT-51145-APO Orbis IS A1R Heat Detector .........................................99

ORB-HT-51146-APO Orbis IS A1R Heat Detector with flashing LED......99

ORB-HT-51147-APO Orbis IS A2S Heat Detector ..........................................99

ORB-HT-51148-APO Orbis IS A2S Heat Detector with flashing LED ......99

ORB-HT-51149-APO Orbis IS BR Heat Detector ............................................99

ORB-HT-51150-APO Orbis IS BR Heat Detector with flashing LED ........99

ORB-HT-51151-APO Orbis IS BS Heat Detector .............................................99

ORB-HT-51152-APO Orbis IS BS Heat Detector with flashing LED .........99

ORB-HT-51153-APO Orbis IS CR Heat Detector .............................................99

ORB-HT-51154-APO Orbis IS CR Heat Detector with flashing LED .........99

ORB-HT-51155-APO Orbis IS CS Heat Detector .............................................99

ORB-HT-51156-APO Orbis IS CS Heat Detector with flashing LED .........99

ORB-HT-51157-APO Orbis IS A1S Heat Detector ..........................................99

ORB-HT-51158-APO Orbis IS A1S Heat Detector with flashing LED ......99

ORB-MB 50018-APO Orbis IS Timesaver Base ...........................................100

ORB-MB-00001-APO TimeSaver Base ...............................................................27

ORB-MB-00002-APO TimeSaver LX Base .........................................................27

ORB-MB-00012-APO Orbis LX Base ....................................................................27

ORB-MB-00019-APO TimeSaver Deep Base ...................................................28

ORB-MB-00001-MAR Orbis Marine TimeSaver Base ....................................92

ORB-OH-13001-APO Orbis Multisensor Detector ..........................................26

ORB-OH-13003-APO Orbis Multisensor Detector with flashing LED ........................................................................26

ORB-OH-43001-MAR Orbis Marine Multisensor Detector ..........................91

ORB-OH-43003-MAR Orbis Marine Multisensor Detector with flashing LED ............................................................91

ORB-OH-53027-APO Orbis IS Multisensor Detector .....................................99

ORB-OH-53028-APO Orbis IS Multisensor with flashing LED ....................99

ORB-OP-12001-APO Orbis Optical Smoke Detector ....................................26

ORB-OP-12003-APO Orbis Optical Smoke Detector with flashing LED ........................................................................26

ORB-OP-42001-MAR Orbis Marine Optical Smoke Detector ....................91

ORB-OP-42003-MAR Orbis Marine Optical Smoke Detector with flashing LED .............................................................91

ORB-OP-52027-APO Orbis IS Optical Smoke Detector ...............................99

ORB-OP-52028-APO Orbis IS Optical Smoke Detector with flashing LED ........................................................................99

ORB-RB-10004-APO TimeSaver Relay Base ...................................................27

ORB-RB-40004-MAR Orbis Marine Relay Base...............................................92

ORB-SW-10005-APO Sav-Wire Base ..................................................................29

XPA-CB-11170-APO XPander A1R Heat Detector and Mounting Base..42

XPA-CB-11171-APO XPander CS Heat Detector and Mounting Base ..42

XPA-CB-12034-APO XPander Optical Smoke Detector and Mounting Base .................................................................42

XPA-CB-13032-APO XPander Multisensor Detector and Mounting Base .................................................................42

XPA-CB-14001-APO XPander Sounder and Sounder Base Red .............89

XPA-CB-14002-APO XPander Sounder and Sounder Base White .........89

XPA-CB-14003-APO XPander Red Sounder Beacon and Red Sounder Base ....................................................................63

XPA-CB-14004-APO XPander Amber Sounder Beacon and White Sounder Base .......................................................63

XPA-CB-14005-APO XPander Clear Sounder Beacon and White Sounder Base .......................................................63

XPA-IN-14007-APO XPander Interface Unit ..................................................43

XPA-MC-14006-APO XPander Manual Call Point ...........................................80

XPA-TE-14010-APO XPander Survey Tool ......................................................43

Index: Product 133

AlarmSense 35

AlarmSense Alarm Relay ..........................................55000-835 ........................37

AlarmSense A1R Heat Detector (Standard) .......55000-190 ........................36

AlarmSense A1R Heat Detector andSounder Base..................................................................55000-196 ........................36

AlarmSense A1R Heat Detector and Sounder Beacon Base .................................................55000-198 ........................36

AlarmSense Base ..........................................................45681-244 ........................37

AlarmSense CS Heat Detector (High Temp) ......55000-193 ........................36

AlarmSense CS Heat Detector and Sounder Base..................................................................55000-197 ........................36

AlarmSense CS Heat Detector and Sounder Beacon Base .................................................55000-199 ........................36

AlarmSense Integrating Optical Smoke Detector ............................................................55000-391 ........................36

AlarmSense Integrating Optical Smoke Detector and Sounder Base ......................55000-393 ........................36

AlarmSense Integrating Optical Smoke Detector and Sounder Beacon Base ......55000-395 ........................36

AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80

AlarmSense Manual Call Point (Surface) .............55000-894 ........................80

AlarmSense Optical Smoke Detector ...................55000-390 ........................36

AlarmSense Optical Smoke Detector and Sounder Base .........................................................55000-392 ........................36

AlarmSense Optical Smoke Detectorand Sounder Beacon Base ........................................55000-394 ........................36

AlarmSense Red Cap ...................................................45681-295 ................ 57, 65

AlarmSense Sounder Base ........................................45681-510 ........................57

AlarmSense Sounder Base LR ................................45681-341 ........................57

AlarmSense Sounder Beacon Base ......................45681-509 ........................65

AlarmSense Sounder Beacon Base LR .................45681-340 ........................65

AlarmSense White Cap ...............................................45681-294 ................ 57, 65

AVAccessories 66

Beacon Enclosure ..........................................................29600-318 ........................67

Magnetic Wand .............................................................29650-001 ........................67

BaseSounders 55

AlarmSense Sounder Base ........................................45681-510 ........................57

AlarmSense Sounder Base LR ................................45681-341 ........................57

Ancillary Base Sounder ...............................................45681-276 ........................56

Integrated Base Sounder ...........................................45681-278 ........................56

Integrated Base Sounder - Slow Whoop .............45681-291 ........................56

Integrated Base Sounder - Slow Whoop with Isolator ....................................................................45681-290 ........................56

Integrated Base Sounder DIN-tone with Isolator ....................................................................45681-300 ........................56

Integrated Base Sounder with Isolator .................45681-277 ........................56

Intelligent Base Sounder ...........................................45681-265 ........................56

Intelligent Base Sounder for Isolating Base ........45681-266 ........................56

Intelligent Base Sounder Slow Whoop ................45681-267 ........................56

Intelligent Base Sounder Slow Whoop for Isolating Base ...........................................................45681-268 ........................56

Red Cap (for Intelligent Base Sounder) ................29600-257 ........................56

Red Cap (for Integrated Base Sounder) ...............45681-293 ........................56

Series 65 Sounder Base ...........................................45681-512 ........................57

Series 65 Sounder Base with Diode ......................45681-513 ........................57

White Cap (for Intelligent Base Sounder) ............26900-256 ........................56

White Cap (for Integrated Base Sounder) ...........45681-292 ........................56

BeaconBases 60

Loop-Powered Beacon Base with Isolator .........45681-333 ........................61

Loop-Powered Beacon Base ....................................45681-335 ........................61

Loop-Powered Beacon Base with Australian Flash ..............................................................45681-337 ........................61

Red Cap .............................................................................45681-293 ........................61

White Cap .........................................................................45681-292 ........................61

Beacons 58

Beacon Enclosure ..........................................................29600-318 ........................59

Intelligent Open-Area Beacon Red Lens ..................55000-009 ........................59

Intelligent Open-Area Beacon Clear Lens ..................55000-010 ........................59

Loop-Powered Beacon Amber ...............................55000-879 ........................59

Loop-Powered Beacon Clear Lens Red Flash ....55000-878 ........................59

Loop-Powered Beacon Red ......................................55000-877 ........................59

DIN-RailInterfaces 75

DIN-Rail Dual Isolator ...................................................55000-802 ........................77

DIN-Rail Input/Output Unit.........................................55000-803 ........................76

DIN-Rail Interface Enclosure (10 units) .................29600-240 ................ 77, 85

DIN-Rail Interface Enclosure (4 units)....................29600-239 ................ 77, 85

DIN-Rail Mains Input/Output Unit ...........................55000-797 ........................76

DIN-Rail Output Unit .....................................................55000-804 ........................76

DIN-Rail Sounder Controller (5 Amperes) ...........55000-182 ........................76

IndexProduct

Index: Product134

DIN-Rail Switch Monitor .............................................55000-822 ........................76

DIN-Rail Switch Monitor Plus ....................................55000-821 ........................77

DIN-Rail Zone Monitor with Isolator.......................55000-812 ........................77

Mini Switch Monitor .....................................................55000-760 ........................77

Discovery 9

Discovery Carbon Monoxide Fire Detector .........58000-300 ........................10

Discovery Heat Detector ............................................58000-400 ........................10

Discovery Ionisation Smoke Detector ...................58000-500 ........................10

Discovery Manual Call Point (non standard)White..................................................................................51800-920 ........................79

Discovery Manual Call Point (non standard) Yellow ................................................51800-927 ........................79

Discovery Manual Call Point (non standard) Blue .....................................................58100-928 ........................79

Discovery Manual Call Point (non standard) Green..................................................58100-929 ........................79

Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79

Discovery Manual Call Point with Isolator - Red (Surface) ..................................................................58100-908 ........................79

Discovery Multisensor Detector ..............................58000-700 ........................10

Discovery Optical Smoke Detector ........................58000-600 ........................10

Discovery Programmer ..............................................53832-030 .....................117

Discovery Sounder Beacon Base ............................45681-393 ........................65

Intelligent Deep Base ..................................................45681-209 ........................11

Isolator ...............................................................................55000-720 ........................11

Intelligent Mounting Base ..........................................45681-210 ........................11

Isolating Base ..................................................................45681-284 ........................11

MiniDisc Remote Indicator.........................................53830-070 ........................12

DiscoveryMarine 87

Discovery Marine Heat Detector ............................58000-400MAR ..............88

Discovery Marine Ionisation Smoke Detector ...58000-500MAR ..............88

Discovery Marine Isolator ..........................................55000-700MAR ..............88

Discovery Marine Isolator Base ...............................45681-211MAR ..............89

Discovery Marine Manual Call Point .....................58100-970MAR ..............89

Discovery Marine Mounting Base ..........................45681-210MAR ..............89

Discovery Marine Multisensor .................................58000-700MAR ..............88

Discovery Marine Optical Smoke Detector .........58000-600MAR ..............88

DiscoveryUL 112

Discovery UL Heat Detector ....................................58000-450 .....................113

Discovery UL Ionization Smoke Detector ............58000-550 .....................113

Discovery UL Multisensor Detector ........................58000-750 .....................113

Discovery UL Photo-Electric Smoke Detector ....58000-650 .....................113

XP95A Isolating Base ...................................................45681-321USA .............114

XP95A 4” Mounting Base ..........................................45681-210USA .............114

XP95A 6” Mounting Base ..........................................45681-225USA .............114

XP95A E-Z Fit Base .......................................................45681-250 .....................114

XP95A Isolator ...............................................................55000-750 .....................114

XP95A Isolator Base .....................................................45681-211USA .............114

ManualCallPoints 78

AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80

AlarmSense Manual Call Point (Surface) .............55000-894 ........................80

Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79

Discovery Manual Call Point with Isolator - Red (Surface) ..................................................................58100-908 ........................79Transparent Hinged Cover for Manual

Call Point ...........................................................................26729-152 ........................79

Waterproof Manual Call Point - Red ......................58100-950 ........................80

Waterproof Manual Call Point with Isolator - Red ...................................................................58100-951 ........................80

XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79

XP95 Manual Call Point with Isolator - Red (Surface) ..................................................................55100-908 ........................79

XPander Manual Call Point ........................................XPA-MC-14006-APO .....80

MiniInterfaces 73

Mini Switch Monitor .....................................................55000-760 ........................74

XP95 Mini Switch Monitor with fly leads ............55000-833 ........................74

XP95 Mini Switch Monitor with fly leads (Interrupt) .........................................................................55000-832 ........................74

MountingAccessories 82

1.5mm Hexagonal Driver ..........................................29600-095 ........................85

Backplate ..........................................................................45681-233 ........................83

Beacon Enclosure ..........................................................29600-318 ........................84

Conduit Box .....................................................................45681-204 ........................83

Deckhead Adaptor PG16-M20 ................................27249-005 ........................84

Detector Ceiling Tile Mounting Box .......................45681-309 ........................84

DIN-Rail Interface Enclosure (10 units) .................29600-240 ........................85

DIN-Rail Interface Enclosure (4 units)....................29600-239 ........................85

Metal Deckhead Mounting Box (M20) ................29600-139 ........................84

Metal Deckhead Mounting Box (PG16) ...............29600-131 ........................84

Module Base ...................................................................38531-822 ........................83

Polycarbonate Deckhead Mounting Box .............45681-217 ........................84

Series 65 to Orbis Base Adaptor .............................ORB-BA-10008-APO .....85

Series 90 to XP95 Base Adaptor .............................45681-238 ........................85

Series 65 Base Cover .................................................45681-370 ........................83

Sounder Ceiling Plate ...................................................45681-311 ........................83

Sounder Ceiling Tile Mounting Box ........................45681-310 ........................87

XP95 Base Cover .........................................................45681-380 ........................83

Orbis 25

MiniDisc Remote Indicator.........................................53832-070 ........................28

Orbis A1R Heat Detector ............................................ORB-HT-11001-APO ......26

Orbis A1R Heat Detector with flashing LED ........ORB-HT-11013-APO ......26

Orbis A1S Heat Detector ............................................ORB-HT-11166-APO ......26

Orbis A1S Heat Detector with flashing LED ........ORB-HT-11167-APO ......26

Orbis A2S Heat Detector ............................................ORB-HT-11002-APO ......26

Orbis A2S Heat Detector with flashing LED ........ORB-HT-11014-APO ......26

Orbis BR Heat Detector ...............................................ORB-HT-11003-APO ......26

Orbis BR Heat Detector with flashing LED ...........ORB-HT-11015-APO ......26

Orbis BS Heat Detector ...............................................ORB-HT-11004-APO ......26

Orbis BS Heat Detector with flashing LED ...........ORB-HT-11016-APO ......26

Orbis CR Heat Detector ...............................................ORB-HT-11005-APO ......26

Orbis CR Heat Detector with flashing LED ...........ORB-HT-11017-APO ......26

Orbis CS Heat Detector ...............................................ORB-HT-11006-APO ......26

Orbis CS Heat Detector with flashing LED ...........ORB-HT-11018-APO ......26

Index: Product 135

Orbis LX Base ..................................................................ORB-MB-00012-APO ....27

Orbis Duct Detector ......................................................53546-023 ........................51

Orbis Heater Base .........................................................ORB-HB-00020-APO .....28

Orbis Multisensor Detector .......................................ORB-OH-13001-APO .....26

Orbis Multisensor Detector with flashing LED .....................................................................ORB-OH-13003-APO .....26

Orbis Optical Smoke Detector ..................................ORB-OP-12001-APO .....26

Orbis Optical Smoke Detector with flashing LED .....................................................................ORB-OP-12003-APO .....26

TimeSaver Base .............................................................ORB-MB-00001-APO ....27

TimeSaver Deep Base .................................................ORB-MB-00019-APO ....28

TimeSaver Diode Base ................................................ORB-DB-00003-APO .....27

TimeSaver LX Base .......................................................ORB-MB-00002-APO ....27

TimeSaver Relay Base ................................................ORB-RB-10004-APO ......27

Sav-Wire Base ................................................................ORB-SW-10005-APO ....28

Polycarbonate Deckhead Mounting Box .............45681-217 ........................84

Waterproof Base Cover ..............................................45681-519 ........................28

OrbisIS 98

Galvanic Barrier ..............................................................29600-378 .....................100

Orbis IS A1R Heat Detector .......................................ORB-HT-51145-APO ......99

Orbis IS A1R Heat Detector with flashing LED .....ORB-HT-51146-APO ......99

Orbis IS A1S Heat Detector .......................................ORB-HT-51157-APO ......99

Orbis IS A1S Heat Detector with flashing LED ......ORB-HT-51158-APO .......99

Orbis IS A2S Heat Detector ...........................................ORB-HT-51147-APO .......99

Orbis IS A2S Heat Detector with flashing LED ......ORB-HT-51148-APO .......99

Orbis IS Adaptor .................................................................ORB-BA-50008-APO ...100

Orbis IS BR Heat Detector ..............................................ORB-HT-51149-APO .......99

Orbis IS BR Heat Detector with flashing LED .........ORB-HT-51150-APO .......99

Orbis IS BS Heat Detector ..............................................ORB-HT-51151-APO .......99

Orbis IS BS Heat Detector with flashing LED .........ORB-HT-51152-APO .......99

Orbis IS CR Heat Detector ..............................................ORB-HT-51153-APO .......99

Orbis IS CR Heat Detector with flashing LED .........ORB-HT-51154-APO .......99

Orbis IS CS Heat Detector ..............................................ORB-HT-51155-APO .......99

Orbis IS CS Heat Detector with flashing LED .........ORB-HT-51156-APO .......99

Orbis IS Multisensor Detector ...................................ORB-OH-53027-APO .....99

Orbis IS Multisensor with flashing LED ..................ORB-OH-53028-APO .....99

Orbis IS Optical Smoke Detector .............................ORB-OP-52027-APO .....99

Orbis IS Optical Smoke Detector with

flashing LED .....................................................................ORB-OP-52028-APO .....99

Orbis IS Timesaver IS Base .......................................ORB-MB-50018-APO .100

OrbisMarine 90

Orbis Marine A1R Heat Detector ............................ORB-HT-41001-MAR .....91

Orbis Marine A1R Heat Detector with

flashing LED .....................................................................ORB-HT-41013-MAR .....91

Orbis Marine A2S Heat Detector ............................ORB-HT-41002-MAR .....91

Orbis Marine A2S Heat Detector with flashing LED .....................................................................ORB-HT-41014-MAR .....91

Orbis Marine BR Heat Detector ...............................ORB-HT-41003-MAR .....91

Orbis Marine BR Heat Detector with flashing LED .....................................................................ORB-HT-41015-MAR .....91

Orbis Marine BS Heat Detector ...............................ORB-HT-41004-MAR .....91

Orbis Marine BS Heat Detector with flashing LED .....................................................................ORB-HT-41016-MAR .....91

Orbis Marine CR Heat Detector ...............................ORB-HT-41005-MAR .....91

Orbis Marine CR Heat Detector with flashing LED .....................................................................ORB-HT-41017-MAR .....91

Orbis Marine CS Heat Detector ................................ORB-HT-41006-MAR .....91

Orbis Marine CS Heat Detector with

flashing LED .....................................................................ORB-HT-41018-MAR .....91

Orbis Marine Multisensor Detector ........................ORB-OH-43001-MAR ....91

Orbis Marine Optical Smoke Detector ..................ORB-OP-42001-MAR ....91

Orbis Marine Relay Base ............................................ORB-RB-40004-MAR .....92

Orbis Marine TimeSaver Base ..................................ORB-MB-00001-MAR ...92

Orbis Marine Multisensor Detector with flashing LED .....................................................................ORB-OH-43003-MAR ....91

Orbis Marine Optical Smoke Detectorwith flashing LED ...........................................................ORB-OP-42003-MAR ....91

Series65A 108

Series 65A 135˚F Heat Detector flashing LED ......55000-139 .....................109

Series 65A 135˚F Heat Detector flashing LED

and magnetic test switch ..........................................55000-138 .....................109

Series 65A 135˚F Heat Detector Standard ..........55000-140 .....................109

Series 65A 170˚F Heat Detector flashing LED ......55000-142 .....................109

Series 65A 170˚F Heat Detector flashing LED

and magnetic test switch ..........................................55000-141 .....................109

Series 65A 170˚F Heat Detector Standard ..........55000-143 .....................109

Series 65A 200˚F Heat Detector flashing LED ......55000-145 .....................109

Series 65A 200˚F Heat Detector flashing LED

and magnetic test switch ..........................................55000-144 .....................109

Series 65A 200˚F Heat Detector Standard ..........55000-146 .....................109

Series 65A 4” 12V End-of-Line Relay Base .........45681-257 .....................110

Series 65A 4” 24V End-of-Line Relay Base .........45681-258 .....................110

Series 65A 4” Auxiliary Relay Base ........................45681-256 .....................110

Series 65A 4” Standard Base ...................................45681-200USA .............110

Series 65A 4” Standard Relay Base .......................45681-255 .....................110

Series 65A 6” E-Z Fit Base .........................................45681-251 .....................111

Series 65A 6” Low Profile Base ...............................45681-232 .....................110

Series 65A 6” Standard Base ...................................45681-220USA .............110

Series 65A Ionization Smoke Detector

flashing LED ...................................................................55000-226 .....................109

Series 65A Ionization Smoke Detector

flashing LED and magnetic test switch ................55000-225 .....................109

Series 65A Ionization Smoke Detector

Standard ...........................................................................55000-227 .....................109

Series 65A Photo-Electric Smoke Detector

flashing LED ...................................................................55000-326 .....................109

Series 65A Photo-Electric Smoke Detector

flashing LED and magnetic test switch ................55000-325 .....................109

Series 65A Photo-Electric Smoke Detector

Standard ...........................................................................55000-327 .....................109

Series65 29

MiniDisc Remote Indicator.........................................53832-070 ........................33

Series 65 12V Relay Base ..........................................45681-508 ........................31

Series 65 Auxiliary Relay Base ...............................45681-246 ........................31

Series 65 Base Cover .................................................45681-370 ........................83

Series 65 Diode Base ...................................................45681-201 ........................31

Index: Product136

Series 65 End-of-Line Relay Base (12V) ..............45681-247 ........................32

Series 65 End-of-Line Relay Base (24V) ..............45681-248 ........................32

Series 65 Sav-Wire Base ............................................45681-206 ........................32

Series 65 Standard Base ............................................45681-200 ........................31

Series 65 A1R Heat Detector flashing LED ..........55000-121 ........................31

Series 65 A1R Heat Detector flashing LED

and magnetic test switch ..........................................55000-120 ........................31

Series 65 A1R Heat Detector Standard ................55000-122 ........................31

Series 65 BR Heat Detector flashing LED ..........55000-126 ........................31

Series 65 BR Heat Detector flashing LED

and magnetic test switch ..........................................55000-125 ........................31

Series 65 BR Heat Detector Standard ...................55000-127 ........................31

Series 65 CR Heat Detector flashing LED ..........55000-131 ........................31

Series 65 CR Heat Detector flashing LED

and magnetic test switch ..........................................55000-130 ........................31

Series 65 CR Heat Detector Standard ...................55000-132 ........................31

Series 65 CS Heat Detector flashing LED ...........55000-136 ........................31

Series 65 CS Heat Detector flashing LED

and magnetic test switch ..........................................55000-135 ........................31

Series 65 CS Heat Detector Standard ...................55000-137 ........................31

Series 65 Integrating Ionisation Smoke

Detector ............................................................................55000-220 ........................30

Series 65 Integrating Ionisation Smoke

Detector flashing LED ..................................................55000-219 ........................30

Series 65 Integrating Ionisation Smoke Detector

flashing LED and magnetic test switch .................55000-218 ........................30

Series 65 Ionisation Smoke Detector

flashing LED .....................................................................55000-216 ........................30

Series 65 Ionisation Smoke Detector

flashing LED and magnetic test switch ................55000-215 ........................30

Series 65 Ionisation Smoke Detector

Standard ...........................................................................55000-217 ........................30

Series 65 Optical Smoke Detector

flashing LED ...................................................................55000-316 ........................30

Series 65 Optical Smoke Detector flashing LED and magnetic test switch ................55000-315 ........................30

Series 65 Optical Smoke Detector Standard ......55000-317 ........................30

Series 65 Sounder Base ..............................................45681-512 ........................57

Series 65 Standard Relay Base ...............................45681-245 ........................32

SounderBeaconBases 64

AlarmSense Red Cap ...................................................45681-295 ........................65

AlarmSense Sounder Beacon Base ......................45681-509 ........................65

AlarmSense Sounder Beacon Base LR .................45681-340 ........................65

AlarmSense White Cap ...............................................45681-294 ........................65

Discovery Sounder Beacon Base ............................45681-393 ........................65

Red Cap .............................................................................45681-293 ........................65

Sounder Beacon Base ..............................................45681-331 ........................65

Sounder Beacon Base Slow Whoop with Isolator ....................................................................45681-332 ........................65

Sounder Beacon Base with Australian Tone ......45681-336 ........................65

Sounder Beacon Base with Isolator .......................45681-330 ........................65

Sounder Beacon Base with Isolator DIN-Tone ....45681-334 ........................65

Sounder Beacon Base with NZ Tone ....................45681-338 ........................65

White Cap .........................................................................45681-292 ........................65

SounderBeacons 62

Intelligent Open-Area Sounder Beacon Clear Lens (Sonos) ........................................................55000-006 ........................63

Intelligent Open-Area Sounder Beacon Red Lens (Sonos) ..........................................................55000-005 ........................63

Multi-Tone Open Area Sounder Beacon Red.....55000-291 ........................63

Multi-Tone Open Area Sounder Beacon Red

with Isolator ....................................................................55000-293 ........................63

Multi-Tone Open Area Sounder Beacon White ..55000-292 ........................63

Multi-Tone Open Area Sounder Beacon White

with Isolator ....................................................................55000-294 ........................63

Weatherproof Multi-Tone Open Area

Sounder Beacon Red ...................................................55000-296 ........................63

Weatherproof Multi-Tone Open Area

Sounder Beacon Red with Isolator .........................55000-298 ........................63

Weatherproof Multi-Tone Open Area

Sounder Beacon White ...............................................55000-297 ........................63

Weatherproof Multi-Tone Open Area Sounder Beacon White with Isolator ....................55000-299 ........................63

XPander Amber Sounder Beacon and

White Sounder Base ....................................................XPA-CB-14004-APO ......63

XPander Clear Sounder Beacon and

White Sounder Base ....................................................XPA-CB-14005-APO ......63

XPander Red Sounder Beacon and Red Sounder Base ........................................................XPA-CB-14003-APO ......63

Sounders 53

Intelligent 100dB(A) Open-Area Sounder Red..55000-278 ........................54

Intelligent 100dB(A) Open-Area Sounder Slow Whoop Red ..........................................................55000-276 ........................54

Intelligent 100dB(A) Open-Area SounderSlow Whoop White ......................................................55000-277 ........................54

Intelligent 100dB(A) Open-Area SounderWhite..................................................................................55000-279 ........................54

Intelligent 100dB(A) Open-AreaWeatherproof Sounder Red ......................................55000-274 ........................54

Intelligent 100dB(A) Open-AreaWeatherproof Sounder White ..................................55000-275 ........................54

Intelligent Open-Area Sounder Red (Sonos)......55000-001 ........................54

Intelligent Open-Area Sounder White (Sonos) ...55000-002 ........................54

XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54

XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54

Specialist 44

Base Mounted Flame Detector Bracket...............29600-458 ........................47

Conventional Duct Smoke Detector ......................53546-021 ........................51

Firebeam Adaptor Plate .............................................29600-353 ........................49

Firebeam Beam Detector 5-40m ...........................29600-350 ........................49

Firebeam Extension Kit 40-80m .............................29600-351 ........................49

Firebeam Extension Kit 80-100m ...........................29600-352 ........................49

Flame Detector Bracket ..............................................29600-203 ........................46

Flame Detector Weathershield................................29600-206 ........................46

Intelligent Base Mounted UV IR² Flame Detector ...........................................................................55000-023 ........................47

Intelligent Base Mounted UV Flame Detector ...55000-022 ........................47

Intelligent Base Mounted IR3 Flame Detector ............................................................................55000-024 ........................47

Index: Product 137

Intelligent Duct Detector ............................................53546-022 ........................51

Intelligent Flameproof IR² Flame Detector ..........55000-295 ........................46

Intelligent Flameproof IR³ Flame Detector ..........55000-021 ........................46

Intelligent IR² Flame Detector ..................................55000-280 ........................46

Intelligent IR3 Flame Detector ..................................55000-020 ........................46

Orbis Duct Detector ......................................................53546-023 ........................51

Reflective Beam Detector (50-100m) .................55000-273 ........................49

Reflective Beam Detector (5-50m).......................55000-268 ........................49

Reflective Beam Detector Backbox .......................29600-241 ........................49

StandardInterfaces 69

Input/Output Unit ..........................................................55000-847 ........................70

Mains Switching Input/Output Unit .......................55000-875 ........................71

Output Unit ......................................................................55000-849 ........................70

Sounder Control Unit ....................................................55000-852 ........................70

Switch Monitor Plus .....................................................55000-841 ........................71

Switch Monitor ...............................................................55000-843 ........................71

Three Channel Input/Output Unit ...........................55000-588 ........................70

Three Channel Input/Output Unit PCB only ........43781-588 ........................70

Zone Monitor Unit .........................................................55000-845 ........................71

TestEquipmentandMaintenance 116

1.5mm Hexagonal Driver (locks detectors to bases) .........................................................................29600-095 ....................118

Aerosol Test Gas ..........................................................29600-225 ....................118

Battery Batons ..............................................................29600-183 ....................118

Battery Charger (No Mains Lead)...........................29600-214 ....................118

Conventional Test Set .................................................53832-020 .....................117

Cordless Heat Detector Tester ................................29600-213 ....................118

Cordless Heat Tester Kit ............................................29600-212 ....................118

CO Test Gas .....................................................................29600-235 .....................114

Detector Extract Tool ..................................................29600-102 ....................118

Discovery Programmer ..............................................53832-030 .....................117

Extension Pole, 1.13m ...............................................29600-103 ....................118

Flame Sensor Test Unit and Case ...........................29600-226 .....................117

Heat Detector Test Pole (110V) .............................29600-110 ....................118

Heat Detector Test Pole (240V) ..............................29600-101 ....................118

Printer for XP95 Test Set ............................................55000-872 .....................117

Smoke Dispenser Head ............................................29600-100 ....................118

Telescopic Pole, 1.26m to 4.5m ............................29600-104 ....................118

Detector Duster .............................................................29600-449 .....................118

Smoke/Heat Unit ..........................................................29600-459 .....................118

Smoke/Heat Kit .............................................................29600-460 .....................118

Smoke/Heat/CO Unit ..................................................29600-461 .....................118

Smoke/Heat/CO Kit .....................................................29600-462 .....................118

6-Pack Replacement Smoke Capsule ...................29600-463 .....................118

3-Pack Replacement Smoke Capsule ...................29600-464 .....................118

6-Pack Replacement CO Capsule ...........................29600-465 .....................118

3-Pack Replacement CO Capsule ...........................29600-466 .....................118

UK Mains Lead ..............................................................29600-215 ....................118

XP95 Test Set .................................................................55000-870 .....................117

XPERT Card Insertion Tool .........................................45681-235 ....................118

XP95 16

Intelligent Deep Base ..................................................45681-209 ........................19

Intelligent Mounting Base ..........................................45681-210 ........................18

Isolator ...............................................................................55000-720 ........................18

Isolator Base ....................................................................45681-211 ........................18

Low Power Relay Base ...............................................45681-242 ........................19

New Isolating Base ......................................................45681-284 ........................18

MiniDisc Remote Indicator.........................................53832-070 ........................19

Polycarbonate Deckhead Mounting Box .............29600-196 ........................19

Printer for XP95 Test Set ............................................55000-872 .....................117

Waterproof Base Cover ..............................................45681-519 ........................19

XP95 Base Cover .........................................................45681-380 ........................83

XP95 Heat Detector High Temperature ...............55000-401 ........................17

XP95 Heat Detector Standard ..................................55000-400 ........................17

XP95 Heater Base .........................................................45681-219 ........................19

XP95 Ionisation Smoke Detector ............................55000-500 ........................17

XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79

XP95 Manual Call Point with Isolator - Red (Surface) ..................................................................55100-908 ........................79

XP95 Multisensor Detector .......................................55000-885 ........................17

XP95 Optical Smoke Detector .................................55000-600 ........................17

XP95 Test Set .................................................................55000-870 .....................117

XP95A 103

XP95A Isolating Base ...................................................45681-321USA .............105

XP95A 4” Low Power Relay Base ..........................45681-242USA .............106

XP95A 4” Mounting Base ..........................................45681-210USA .............105

XP95A 6” Mounting Base ..........................................45681-225USA .............105

XP95A Dual Priority Switch Monitor Module .....55000-790 .....................107

XP95A E-Z Fit Base .......................................................45681-250 .....................104

XP95A Heat Detector ..................................................55000-450 .....................104

XP95A Ionization Smoke Detector .........................55000-550 .....................104

XP95A Isolator ...............................................................55000-750 .....................105

XP95A Isolator Base .....................................................45681-211USA .............105

XP95A Loop Powered Beam Detector ................55000-266 .....................104

XP95A Mini Priority Switch Monitor Module ......55000-830 .....................106

XP95A Mini Switch Monitor Module .....................55000-831 .....................106

XP95A Multisensor Detector ....................................55000-886 .....................104

XP95A Photo-Electric Smoke Detector ................55000-650 .....................104

XP95A Priority Switch Monitor Module ................55000-806 .....................107

XP95A Relay Output Module ...................................55000-863 .....................107

XP95A Sounder Control Module .............................55000-825 .....................107

XP95A Switch Monitor Input/Output Module ...55000-820 .....................107

XP95A Switch Monitor Module ...............................55000-805 .....................106

Mini Monitor Module ...................................................55000-765 .....................106

XP95IS 95

IS Galvanic Barrier .........................................................29600-098 ........................97

XP95 IS Heat Detector.................................................55000-440 ........................96

XP95 IS Ionisation Smoke Detector .......................55000-540 ........................96

XP95 IS Manual Call Point MEDC Break Glass - Black/Yellow Stripes .....................................55000-966 ........................97

Index: Product138

XP95 IS Manual Call Point MEDC Break Glass - Blue ......................................................................55000-964 ........................97

XP95 IS Manual Call Point MEDC Break Glass - Red .......................................................................55000-960 ........................97

XP95 IS Manual Call Point MEDC Break Glass - Yellow .................................................................55000-962 ........................97

XP95 IS Manual Call Point MEDC Break Glass with flap - Black/Yellow Stripes ..................55000-967 ........................97

XP95 IS Manual Call Point MEDC Break Glass with flap - Blue ...................................................55000-965 ........................97

XP95 IS Manual Call Point MEDC Break Glass with flap - Red ....................................................55000-961 ........................97

XP95 IS Manual Call Point MEDC Break Glass with flap - Yellow ..............................................55000-963 ........................97

XP95 IS Manual Call Point MEDC Push Button - Black/Yellow Stripes ..................................55000-973 ........................97

XP95 IS Manual Call Point MEDC Push Button - Blue ...................................................................55000-972 ........................97

XP95 IS Manual Call Point MEDC PushButton - Red ....................................................................55000-970 ........................97

XP95 IS Manual Call Point MEDC Push Button - Yellow ..............................................................55000-971 ........................97

XP95 IS Manual Call Point With Flap - Blue/White.......................................................................55000-945 ........................97

XP95 IS Manual Call Point Without Flap - Blue/White.......................................................................55100-944 ........................97

XP95 IS Manual Call Point Without Flap - Red ...55100-940 ........................97

XP95 IS Manual Call Point Without Flap - Yellow 55100-942 ........................97

XP95 IS Mounting Base ..............................................45681-215 ........................97

XP95 IS Optical Smoke Detector .............................55000-640 ........................97

XP95 Protocol Translator (Dual) ..............................55000-856 ........................97

XP95 Protocol Translator (Single) ...........................55000-855 ........................97

XPander 41

XPander A1R Heat Detector and Mounting Base ..XPA-CB-11170-APO ......42

XPander Amber Sounder Beacon and White Sounder Base ....................................................XPA-CB-14004-APO ......63

XPander Clear Sounder Beacon and White Sounder Base ....................................................XPA-CB-14005-APO ......63

XPander CS Heat Detector and Mounting Base XPA-CB-11171-APO ......42

XPander Interface Unit ................................................XPA-IN-14007-APO .......43

XPander Manual Call Point ........................................XPA-MC-14006-APO .....80

XPander Multisensor Detector and Mounting Base ....................................................................................XPA-CB-13032-APO ......42

XPander Optical Smoke Detector and Mounting Base ...............................................................XPA-CB-12034-APO ......42

XPander Red Sounder Beacon and Red Sounder Base ........................................................XPA-CB-14003-APO ......63

XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54

XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54

XPander Survey Tool ...................................................XPA-TE-14010-APO .......43

XPERTCards 22

Blank XPERT Card ..........................................................38531-771 ........................23

Pre-Addressed XPERT Cards .....................................45682-127 ........................23

PP2327/2009/Issue 4

ApolloOverseasOffices

ApolloAmerica821 Ulrich AvenueLouisvilleKentucky40219USA

Tel: +1 502 964 6565Fax: +1 502 964 6229Email: [email protected]: www.apollo-fire.com

ApolloGermanyApollo GmbHAm Anger 31D-33332 GüterslohGermany

Tel: +49 5241 33060Fax: +49 5241 330629Email: [email protected]: www.apollo-feuer.de

ApolloSpainApollo Fire Detectors S.A.Calle Rio Tietar 12Nave 6Pol Ind El Nogal28110 AlgeteMadridSpain

Tel: +34 9162 89209Fax: +34 9162 90168Email: informació[email protected]: www.apollo-fire.es

ApolloIrelandApollo Ireland8 Willbrook RoadRathfarnhamDublin 14Republic of Ireland

Tel: +353 1 493 3896Email: [email protected]: www.apollo-fire.ie

ApolloChinaApollo China24D Huamin Empire Plaza726 Yan An Road (W)Shanghai200050The People’s Republic of China

Tel: +86 21 5237 0922Fax: +86 21 5237 0920Email: [email protected]: www.apollo-fire.com.cn

© Apollo Fire Detectors Ltd 2007-2009