FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
Fire Rated Cable Support SystemsAS/NZ 3013:2005 - Classification WS5X – 2 hour fire rating to 1050 Degrees Celsius
FIRST CHOICE FOR • TRAY • LADDER • STRUT • HYGROUND • CABLE MESH
Western Australia 91 - 93 McDowell Street, Welshpool, Western Australia, 6106
Head Office Phone 08 9458 1188
Fax 08 9458 1182
email [email protected]
New South Wales 11 Sunblest Crescent, Mt Druitt, New South Wales 2770
Phone 02 9832 3377
Fax 02 9832 0733
email [email protected]
Tasmania Gordon Wood & Co
31 Sunderland Street, Moonah, Tasmania 7009
Phone 03 627 34455
Fax 03 627 34734
email [email protected]
Queensland Brisbane Branch161 Jackson Road, Sunnybank Hills
Queensland, 4109
Phone 07 3219 6108
Fax 07 3219 6208
email [email protected]
Townsville Branch75 - 81 Toll Street, Mount St John
Queensland, 4818
Phone 1300 287 639
Fax 1300 329 669
email [email protected]
www.burndycss.com.au
February 2019
1300 BURNDY 1300 FAX NOW(1300 287 639) (1300 329 669)
iFIRE RATED CABLE SUPPORT SYSTEMS
About Burndy
Burndy is an Australian owned and operated company. Our products are Australian made to Australian standards.
Pioneers of the original Laddertray systems, Burndy are considered by many to have established the benchmark for quality and performance in commercial construction applications.
For over 35 years, it has been widely held that Burndy have been leaders in their field. Their continuous efforts at improving both products and services have been rewarded by a wide and growing user base and resellers.
Established in 1982, Phoenix Metalform, the parent company of Burndy, are a significant participant in sheet metal roll forming and fabrication.
With branch offices throughout Australia, Burndy is always conveniently placed to service its customers.
Manufactured in a wide range of materials including Hot Dip Galvanised Steel, Aluminium and Stainless Steel, there is a Burndy product to suit your specific application and environmental conditions.
Always striving to meet the growing demands of a sophisticated market, the Burndy range has evolved to provide a genuine one stop shop with the ability to satisfy your cable support needs.
Our mission is to be your first choice for the supply of cable support systems in Australia, and having a dedicated team of professionals is an essential platform in achieving that goal.
You can be assured of Burndy’s commitment to continually improving our range, our product quality, our value for money and our delivery turnaround time.
i
Company Profile
ii FIRE RATED CABLE SUPPORT SYSTEMS
Fire Rated AS/NZ 3013:2005
Fire Rated AS/NZ 3013:2005 Introduction
Electrical installations are the number one cause of fire in modern buildings in Australia. Fire rated cable support systems can reduce the human cost of fires as well as limit damage caused by early collapse.
Burndy have played a major role in developing Fire Rated Cable Support Systems in Australia. As an Australian manufacturer established in 1982 we have over 35 years’ experience in Cable Support Systems. In that time we have built up a wealth of knowledge and experience.
Our extensive range of Fire Rated Cable Support Systems has been developed in-house utilising our industry experience. All of our products comply with AS/NZS 3013:2005, WS5X 2 hour fire rating to 1050 degrees.
Our Fire Rated systems are available in a range of finishes• Hot Dipped Galvanised• Pre Galvanised• Powder Coated in a range of colour options
Widths available 150-600mm
Cable laying depths available 45mm to 105mm
Load ratings up to 150 kg per metre
Providing innovative & value for money solutions
Our aim is to provide our customers Fire Rated AS/NZS 3013:2005 compliant systems. Our wealth of knowledge can ensure compliance as well as innovative economical solutions to ensure our customers obtain the best value for money systems in the market.
Our large range allows us to offer choice in finish, load rating, installation time savings and designs allowing for installation space.
When new regulations are introduced you can trust the team at Burndy has up-to-date compliant systems.
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
9.1FIRE RATED CABLE SUPPORT SYSTEMS
CONTENTS
9 FIRE RATED 9.1
FR50L Fire Rated Ladder (NEMA 2 Side Rail) 9.2
FR50L AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.3
FR50VL Fire Rated Ladder (NEMA 2 Side Rail) 9.4
FR50VL AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.5
FR60L Fire Rated Ladder (NEMA 3 Side Rail) 9.6
FR60L AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.7
FR70L Fire Rated Ladder (NEMA 4 Side Rail) 9.8
FR70L AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.9
FR100L Fire Rated Ladder (NEMA 4 Side Rail) 9.10
FR100L AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.11
FR150L Fire Rated Ladder (NEMA 4 Side Rail) 9.12
FR150L AS/NZ 3013:2005 Fire Rated Ladder Arrangement 9.13
FR50LT3 Fire Rated Laddertray (LT3) 9.14
FR50LT3 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement 9.15
FR12LT5 Fire Rated Laddertray (LT5) 9.16
FR12LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement 9.17
FR20LT5 Fire Rated Laddertray (LT5) 9.18
FR20LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement 9.19
FR7BCM Fire Rated Cable Mesh 9.20
FR7BCM AS/NZ 3013:2005 Fire Rated Cable Mesh Arrangement 9.21
FR5C Fire Rated Cable Channel 9.22
FR5C AS/NZ 3013:2005 Fire Rated Cable Channel Arrangement 9.23
Fire Rated Accessories 9.24
Fire Rated Swivel Bracket Heavy Duty 9.24
Fire Rated Swivel Bracket Medium Duty 9.24
Fire Rated Beam Clamp 9.24
Fire Rated Cantilever Bracket 9.25
Fire Rated Summary Chart 9.26
9.2 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR50L Fire Rated Ladder (NEMA 2 Side Rail)AS/NZ 3013:2005
FR50L AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 45 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Stainless Steel Gr316 Passivated Finish
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR50L arrangement.
Custom fittings are available upon request.
Uniform load rating of 50 kg per metre.
Maximum support span of 1.5 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N2L150RIH-F6 150 6000 18
N2L300RIH-F6 300 6000 18
N2L450RIH-F6 450 6000 18
N2L600RIH-F6 600 6000 18
Kit Ordering Code FR50L<width>
9.3FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR50L Fire Rated Ladder (NEMA 2 Side Rail)AS/NZ 3013:2005
4040
6.0
6.0
41
.3
41.3
82
.6
94
.6
30.01
4.0
30.0
2.0
15
0.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
HANGING TRAPEZE FR NEMA 3ISOMETRIC VIEW
4040
6.0
6.0
41.3
41.3
82.6
94.6
89
WIDTH
132
30
27
16
WIDTH
51
94.0
26.8
15.0
1.6
16.0NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
ITEM NO. QTY. WEIGHT MATERIAL PART NUMBER DESCRIPTION COMMENT
1 1 0.51 HDG TS600FRH HANGING BEAM 710LG (B1001 & 4 SPACER ) INC. IN CS09
2 4 0.00 NYLON BTHF12 M12 TOP HAT WASHER INC. IN CS09
3 4 0.01 S/S 316 FW12S M12 ROUND WASHER INC. IN CS09
4 4 0.01 S/S 316 HN12S M12 HEX NUT INC. IN CS09
5 4 0.00 S/S 316 SW12S M12 SPRING WASHER INC. IN CS09
6 2 0.05 HDG B1008H M10 CHANNEL NUT INC. IN CS09
7 2 0.01 HDG HDH HOLD DOWN BRACKET INC. IN CS09
8 2 0.03 HDG HS1030H M10 HEX BOLT INC. IN CS09
9 2 - S/S 316 TR12S M12 S/S THREADED ROD NOT INC.
10 1 - HDG NEMA 3 FR 600 NEMA 3 LADDER FR 600 NOT INC. REFER CLK6
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MCHDG 390 (MINIMUM) WD
18.05.17 12.06.17 E18.05.17CS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.4 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR50VL Fire Rated Ladder (NEMA 2 Side Rail)AS/NZ 3013:2005
FR50VL AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 45 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR50L arrangement.
Custom fittings are available upon request.
Uniform load rating of 50 kg per metre.
Maximum support span of 1.0 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N2L150RIH-F6 150 6000 18
N2L300RIH-F6 300 6000 18
N2L450RIH-F6 450 6000 18
N2L600RIH-F6 600 6000 18
Kit Ordering Code FR50VL<width>
9.5FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR50VL Fire Rated Ladder (NEMA 2 Side Rail)AS/NZ 3013:2005
CABLE SUPPORT SYSTEMS
11.4
FR50VL Fire Rated Ladder (Nema 2 Side Rail)AS/NZ 3013:2005
FR50VL AS/NZ 3013:2005 Fire Rated Ladder Arrangement
CABLE SUPPORT SYSTEMS
11.4
FR50VL Fire Rated Ladder (Nema 2 Side Rail)AS/NZ 3013:2005
FR50VL AS/NZ 3013:2005 Fire Rated Ladder Arrangement
/Drawing No.
Title
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF BURNDY ELECTRICAL PRODUCTS
FAX - (07) 3219 6208PHONE - (07) 3219 6108
Queensland 4109Sunybank Hills161 Jackson Road
Burndy ElectricalSheetRevision
DateDrawn By
DD
CC
BB
AA
6
6
5
5
4
4 3
2
2
1
1
Approved ByAQ
1A4 1
27/10/2014
BURNDY-141027-1
N3LRI-VFR-T2E
FERNANDO.D 1000
1000
1000
1000
1000
A
DETAIL A
NEMA 2/3 CABLE LADDER
CABLE LADDER RUNG
SQUARE WASHERB1064H
HN12HDG
HKD 2HR FIRE RATED
THREADED RODTR12HDG
NOTE:
TEST REFERENCE EWFA 26786700.1
/Drawing No.
Title
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF BURNDY ELECTRICAL PRODUCTS
FAX - (07) 3219 6208PHONE - (07) 3219 6108
Queensland 4109Sunybank Hills161 Jackson Road
Burndy ElectricalSheetRevision
DateDrawn By
DD
CC
BB
AA
6
6
5
5
4
4 3
2
2
1
1
Approved ByAQ
1A4 1
27/10/2014
BURNDY-141027-1
N3LRI-VFR-T2E
FERNANDO.D 1000
1000
1000
1000
1000
A
DETAIL A
NEMA 2/3 CABLE LADDER
CABLE LADDER RUNG
SQUARE WASHERB1064H
HN12HDG
HKD 2HR FIRE RATED
THREADED RODTR12HDG
NOTE:
TEST REFERENCE EWFA 26786700.1
9.6 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR60L Fire Rated Ladder (NEMA 3 Side Rail)AS/NZ 3013:2005
FR60L AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 84 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR60L arrangement.
Custom fittings are available upon request.
Uniform load rating of 60 kg per metre.
Maximum support span of 1.5 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N3L150RIH-F6 150 6000 18
N3L300RIH-F6 300 6000 18
N3L450RIH-F6 450 6000 18
N3L600RIH-F6 600 6000 18
Kit Ordering Code FR60L<width>
9.7FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR60L Fire Rated Ladder (NEMA 3 Side Rail)AS/NZ 3013:2005
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41
.3
41.3
82
.6
94
.6
30.01
4.0
30.0
2.0
15
0.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
HANGING TRAPEZE FR NEMA 3ISOMETRIC VIEW
4040
6.0
6.0
41.3
41.3
82.6
94.6
89.1
WIDTH
132.
0
30.0
27.0
16.0 1.6
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
ITEM NO. QTY. WEIGHT MATERIAL PART NUMBER DESCRIPTION COMMENT
1 1 0.51 HDG TS600FRH HANGING BEAM 710LG (B1001 & 4 SPACER ) INC. IN CS09
2 4 0.00 NYLON BTHF12 M12 TOP HAT WASHER INC. IN CS09
3 4 0.01 S/S 316 FW12S M12 ROUND WASHER INC. IN CS09
4 4 0.01 S/S 316 HN12S M12 HEX NUT INC. IN CS09
5 4 0.00 S/S 316 SW12S M12 SPRING WASHER INC. IN CS09
6 2 0.05 HDG B1008H M10 CHANNEL NUT INC. IN CS09
7 2 0.01 HDG HDH HOLD DOWN BRACKET INC. IN CS09
8 2 0.03 HDG HS1030H M10 HEX BOLT INC. IN CS09
9 2 - S/S 316 TR12S M12 S/S THREADED ROD NOT INC.
10 1 - HDG NEMA 3 FR 600 NEMA 3 LADDER FR 600 NOT INC. REFER CLK6
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MCHDG 390 (MINIMUM) WD
18.05.17 12.06.17 E18.05.17CS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.341.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.8 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR70L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
FR70L AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 102 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR70L arrangement.
Custom fittings are available upon request.
Uniform load rating of 70 kg per metre.
Maximum support span of 1.5 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N4L150RIH-F6 150 6000 18
N4L300RIH-F6 300 6000 18
N4L450RIH-F6 450 6000 18
N4L600RIH-F6 600 6000 18
Kit Ordering Code FR70L<width>
9.9FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR70L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41
.3
41.3
82
.6
94
.6
30.01
4.0
30.0
2.0
15
0.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.10 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR100L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
FR100L AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 102 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR100L arrangement.
Custom fittings are available upon request.
Uniform load rating of 100 kg per metre.
Maximum support span of 1.0 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N4L900RIH-F6 900 6000 18
Kit Ordering Code FR100L<width>
9.11FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR100L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41
.3
41.3
82
.6
94
.6
30.01
4.0
30.0
2.0
15
0.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.12 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR150L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
FR150L AS/NZ 3013:2005 Fire Rated Ladder Arrangement
Specifications - Standard Length 6.0 metres.
- Cable Ladder Rung Spacing 333 mm
- Cable laying depth 102 mm
Surface Finish Available Finish
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR150L arrangement.
Custom fittings are available upon request.
Uniform load rating of 150 kg per metre.
Maximum support span of 1.0 metres.
Ladder
Ordering Code Width mm Length mm No of Rungs
N4L150RIH-F6 150 6000 18
N4L300RIH-F6 300 6000 18
N4L450RIH-F6 450 6000 18
N4L600RIH-F6 600 6000 18
Kit Ordering Code FR150L<width>
9.13FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR150L Fire Rated Ladder (NEMA 4 Side Rail)AS/NZ 3013:2005
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41
.3
41.3
82
.6
94
.6
30.01
4.0
30.0
2.0
15
0.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
4040
6.0
6.0
41.3
41.3
82.6
94.6
30.0
14.0
30.0
2.0
150.0
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS4680.4.FOR LADDER ASSEMBLY AND DETAILS REFER TO PART CLK6.
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
161 Jackson Road,
Sunnybank Hills,
QLD 4109
Ph: 3219 6108
Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD MC WD
ECS09
DRAWN
CARBON STEEL
HDG
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.14 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR50LT3 Fire Rated Laddertray (LT3)AS/NZ 3013:2005
FR50LT3 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specifications - Standard Length 3.0 metres.
- Cable laying depth 40 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR50LT3 arrangement.
Uniform load rating of 50 kg per metre.
Maximum support span of 1.0 metres.
Cable Laying Width mm
Pre-GalvanisedOverall Width
mm150 LT3150G 172
300 LT3300G 322
450 LT3450G 472
600 LT3600G 622
Kit Ordering Code FR50LT3<width>
11.13CABLE SUPPORT SYSTEMS
FR50LT3 Fire Rated Laddertray (LT3)AS/NZ 3013:2005
FR50LT3 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specications - Standard Length 3.0 metres. - Cable laying depth 40 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special nishes on request against rm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classication WS5X. It is designed and tested to achieve 2 hour re rating at 1050 deg. Centigrade. Fire rating only applies when used as a complete FR50LT3 arrangement.
Uniform load rating of 50 kg per metre.
Maximum support span of 1.0 metres.
Ordering Code FR50LT3 will include all required items in this arrangement
Cable Laying Widthmm
Pre-Galvanised Overall Widthmm 40 50
150300450600
LT3150GLT3300GLT3450GLT3600G
172322472622
Hot Dip Galvanised to AS/NZ 4680:2006
9.15FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR50LT3 Fire Rated Laddertray (LT3)AS/NZ 3013:2005
61.9 9.
3
41.33
WIDTH
43.3
49.0
11.0
17.0
5.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
61.9 9.
3
41.33
WIDTH
43.3
49.0
11.0
17.0
5.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
61.9 9.
3
41.33
WIDTH
43.3
49.0
11.0
17.0
5.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.16 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR12LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
FR12LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specifications - Standard Length 3.0 metres.
- Cable laying depth 75 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR12LT5 arrangement.
Uniform load rating of 13 kg per metre.
Maximum support span of 1.5 metres.
Cable Laying Width mm
Pre-GalvanisedOverall Width
mm150 LT5150G 172
300 LT5300G 322
Kit Ordering Code FR12LT5<width>
11.15CABLE SUPPORT SYSTEMS
FR12LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
FR12LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specications - Standard Length 3.0 metres. - Cable laying depth 75 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special nishes on request against rm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classication WS5X. It is designed and tested to achieve 2 hour re rating at 1050 deg. Centigrade. Fire rating only applies when used as a complete FR12LT5 arrangement.
Uniform load rating of 13 kg per metre.
Maximum support span of 1.5 metres.
Ordering Code FR12LT5 will include all required items in this arrangement
Cable Laying Widthmm
Pre-Galvanised Overall Widthmm
150300450600
LT5150GLT5300GLT5450GLT5600G
172322472622
75 85
Hot Dip Galvanised to AS/NZ 4680:2006
9.17FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR12LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
61.9 9.
3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
61.9 9.
3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
61.9 9.
3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.18 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR20LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
FR20LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specifications - Standard Length 3.0 metres.
- Cable laying depth 75 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR20LT5 arrangement.
Uniform load rating of 19.6 kg per metre.
Maximum support span of 1.0 metres.
Cable Laying Width mm
Pre-GalvanisedOverall Width
mm150 LT5150G 172
300 LT5300G 322
Kit Ordering Code FR20LT5<width>
11.15CABLE SUPPORT SYSTEMS
FR12LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
FR12LT5 AS/NZ 3013:2005 Fire Rated Laddertray Arrangement
Specications - Standard Length 3.0 metres. - Cable laying depth 75 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special nishes on request against rm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classication WS5X. It is designed and tested to achieve 2 hour re rating at 1050 deg. Centigrade. Fire rating only applies when used as a complete FR12LT5 arrangement.
Uniform load rating of 13 kg per metre.
Maximum support span of 1.5 metres.
Ordering Code FR12LT5 will include all required items in this arrangement
Cable Laying Widthmm
Pre-Galvanised Overall Widthmm
150300450600
LT5150GLT5300GLT5450GLT5600G
172322472622
75 85
Hot Dip Galvanised to AS/NZ 4680:2006
9.19FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR20LT5 Fire Rated Laddertray (LT5)AS/NZ 3013:2005
61.9 9.
3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
61.9 9.
3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
161
.9 9.3
41.3
3
78.6
WIDTH
5.7
11.0
17.00.7
NOTES:1. ALL SHARP EDGES AND BURRS TO BE REMOVED.2. ALL LINEAR TOLERANCE TO BE +/-1.0mm, ALL ANGULAR TO BE +/-1.0 DEGREE U.N.O.3. ALL PRE GALVANISED PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1397.4. ALL HDG PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS/NZ1365, AS1594, AS/NZS46805. ALL STAINLESS STEEL PRODUCT TO BE FABRICATED IN ACCORDANCE WITH AS1449 & AS2837
TECHNICAL INFORMATION
LADDER TYPE NEMA 1 LADDER NON-FR LADDER WIDTH 600mm
TIER QUANTITY 2 MAX SPAN 3m
DESIGN LIFE 25 YEARS LADDER LOAD CAPACITY 150kg/m/TIER
FIRE RATED NO FIRE TEST REPORT No NOT REQUIRED
EXPOSURE CLASS C4
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
Drawing No.
Drawn RevisionInitiated: Approved:
Date :Finish
Material
GradeDESCRIPTION DATE APP'D
REVISIONS
DO NOT SCALE
161 Jackson Road,Sunnybank Hills,QLD 4109
Ph: 3219 6108Fax: 3219 6208
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV FD ZD
A ISSUED FOR INTERNAL REVIEW 04/11/2018
LT5 LADDER TRAY ASSEMBLY
FD
AS PER B.O.M. FD
28.06.18 29.06.18 A28.06.18
LT5
LT5
GENERAL ARRANGEMENT
DRAWN
ZD AS PER B.O.M.
AS PER B.O.M.
A A
B B
C C
D D
6
6
5
5
4
4
3
3
2
2
1
1
9.20 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR7BCM Fire Rated Cable MeshAS/NZ 3013:2005
FR7BCM AS/NZ 3013:2005 Fire Rated Cable Mesh Arrangement
Specifications - Standard Length 3.0 metres.
- Cable laying depth 50 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR7BCM arrangement.
Uniform load rating of 7 kg per metre.
Maximum support span of 1.0 metres.
Ordering Code Height mm Width mm
BCM150PG 50 150
BCM300PG 50 300
Kit Ordering Code FR7BCM<width>
11.19CABLE SUPPORT SYSTEMS
FR7BCM Fire Rated Cable MeshAS/NZ 3013:2005
FR7BCM AS/NZ 3013:2005 Fire Rated Cable Mesh Arrangement
Specications - Standard Length 3.0 metres. - Cable laying depth 50 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special nishes on request against rm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classication WS5X. It is designed and tested to achieve 2 hour re rating at 1050 deg. Centigrade. Fire rating only applies when used as a complete FR7BCM arrangement.
Uniform load rating of 7 kg per metre.
Maximum support span of 1.0 metres.
Ordering Code FR7BCM will include all required items in this arrangement
Ordering Code
BCM150PGBCM300PGBCM450PGBCM600PG
50505050
150300450600
25
50 50 50
50
o20
width
Heightmm
Widthmm
Hot Dip Galvanised to AS/NZ 4680:2006
9.21FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR7BCM Fire Rated Cable MeshAS/NZ 3013:2005
41.3
41.3
WIDTH
54.5
4.5
G.W. M.C.
11.5.179.5.17
MESH 300W PRE GAL
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
A4Drawing No.
Drawn
11
Burndy Cable Support Systems
/SheetRevision
Initiated
DD
CC
BB
AA
6
6
5
5
4
4
3
3
2
2
1
1
Approved
Date :Finish
Material
Grade
UNLESS OTHERWISE SPECIFIED ALL
TOLERANCESLINEAR =+/- 1.0ANGULAR =+/- 1.0 Degree
DIMENSIONS ARE IN MILLIMETRES
REMOVE ALL SHARP EDGES AND BURRS
DESCRIPTION DATE APP'D
REVISIONS
NOTES:
161Jackson Road,Sunnybank Hills,Qld 4109
Ph: 3219 6108Fax: 3219 6208
THIRD ANGLE PROJECTION
By : By : By :
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV
41.3
41.3
WIDTH
54.5
4.5
G.W. M.C.
11.5.179.5.17
MESH 300W PRE GAL
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
A4Drawing No.
Drawn
11
Burndy Cable Support Systems
/SheetRevision
Initiated
DD
CC
BB
AA
6
6
5
5
4
4
3
3
2
2
1
1
Approved
Date :Finish
Material
Grade
UNLESS OTHERWISE SPECIFIED ALL
TOLERANCESLINEAR =+/- 1.0ANGULAR =+/- 1.0 Degree
DIMENSIONS ARE IN MILLIMETRES
REMOVE ALL SHARP EDGES AND BURRS
DESCRIPTION DATE APP'D
REVISIONS
NOTES:
161Jackson Road,Sunnybank Hills,Qld 4109
Ph: 3219 6108Fax: 3219 6208
THIRD ANGLE PROJECTION
By : By : By :
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV
41.3
41.3
WIDTH
54.5
4.5
G.W. M.C.
11.5.179.5.17
MESH 300W PRE GAL
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
A4Drawing No.
Drawn
11
Burndy Cable Support Systems
/SheetRevision
Initiated
DD
CC
BB
AA
6
6
5
5
4
4
3
3
2
2
1
1
Approved
Date :Finish
Material
Grade
UNLESS OTHERWISE SPECIFIED ALL
TOLERANCESLINEAR =+/- 1.0ANGULAR =+/- 1.0 Degree
DIMENSIONS ARE IN MILLIMETRES
REMOVE ALL SHARP EDGES AND BURRS
DESCRIPTION DATE APP'D
REVISIONS
NOTES:
161Jackson Road,Sunnybank Hills,Qld 4109
Ph: 3219 6108Fax: 3219 6208
THIRD ANGLE PROJECTION
By : By : By :
Date : Date :
PRODUCT DESCRIPTION
PART NUMBER
REV
41.3
41.3
WIDTH
54.5
4.5
G.W.M.C.
11.5.17 9.5.17
MESH 300W PRE GAL
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF PHOENIX STEEL SALES PTY LTD.
A4Drawing No.
Drawn
1 1
Burndy Cable Support Systems
/Sheet Revision
Initiated
D D
C C
B B
A A
6
6
5
5
4
4
3
3
2
2
1
1
Approved
Date : Finish
Material
Grade
UNLESS OTHERWISE SPECIFIED ALL
TOLERANCESLINEAR =+/- 1.0ANGULAR =+/- 1.0 Degree
DIMENSIONS ARE IN MILLIMETRES
REMOVE ALL SHARP EDGES AND BURRS
DESCRIPTIONDATEAPP'D
REVISIONS
NOTES:
161Jackson Road,Sunnybank Hills,Qld 4109
Ph: 3219 6108Fax: 3219 6208
THIRD ANGLE PROJECTION
By :By :By :
Date :Date :
PRODUCT DESCRIPTION
PART NUMBER
REV
9.22 FIRE RATED CABLE SUPPORT SYSTEMS
INFORMATION
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
FR5C Fire Rated Cable ChannelAS/NZ 3013:2005
FR5C AS/NZ 3013:2005 Fire Rated Cable Channel Arrangement
Specifications - Standard Length 6.0 metres.
- Cable laying depth 45 mm
Surface Finish Available Finish
Pre Galvanised to AS1397
Hot Dip Galvanised to AS/NZ 4680:2006
Note - The Burndy Fire Rated Systems requires no on-site welding to cut and rejoin.
- Powder coating and special finishes on request against firm orders only and are non returnable.
The Fire Rated System complies with Australian and New Zealand Standard AS/NZ 3013:2005 Classification WS5X. It is designed and tested to achieve 2 hour fire rating at 1050 degrees Celsius.
Fire rating only applies when used as a complete FR5C arrangement.
Uniform load rating of 5 kg per metre.
Maximum support span of 1.5 metres.
Ordering Code Height mm Width mm
FR5C 62 42
Kit Ordering Code FR5C
9.23FIRE RATED CABLE SUPPORT SYSTEMS
ARRANGEMENTFR5C Fire Rated Cable ChannelAS/NZ 3013:2005
1500 1500 1500
HS1020ZHS1020Z HN10Z
HN10Z
FW10Z
FW10ZB1008Z B1008Z
TR10Z
B5500G 6000L 30kg/m
B1047H
THIS DRAWING IS ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE REPRODUCED WITHOUT THE PERMISSION OF BURNDY ELECTRICAL PRODUCTS
A4Drawing No.
Title
Approved By
PHONE - (07) 3219 6108FAX - (07) 3219 6208
161 Jackson RoadSunnybank HillsQueensland 4109
11
Burndy Electrical/
SheetRevision
DateDrawn By
DD
CC
BB
AA
6
6
5
5
4
4
3
3
2
2
1
1
AQ FERNANDO DIFAZIO 17/06/2015
SD 8 of 10 B5500G 1.5m SPAN 30kg/m
BURNDY-150617-3
9.24 FIRE RATED CABLE SUPPORT SYSTEMS
Fire Rated Accessories
Fire Rated Swivel Bracket Heavy Duty
Fire Rated Swivel Bracket Medium Duty
Fire Rated Beam Clamp
Ordering Code BFRSBHDH
Ordering Code BFRSBMDH
Ordering Code FRMDSBBC
9.25FIRE RATED CABLE SUPPORT SYSTEMS
Fire Rated Accessories
FIRE RATED
AS / N Z 3 0 1 3 : 2
0 05
Fire Rated Cantilever Bracket
Ordering Code Length Load Capacity kg
CLB335FRH 335 100
CLB485FRH 485 100
CLB635FRH 635 100
CLB335FRH CLB485FRH CLB635FRH
9.26 FIRE RATED CABLE SUPPORT SYSTEMS
Fire Rated Summary Chart
Fire Rated Options
Page Kit Code Product Load
RatingSupport Included
Cable Laying Depth
Cable Laying Width
LengthsSupport
SpanOrientation
9.2 FR50LNema 2 Cable Ladder
50kg metre
Trapeze / Cantilever
45mm
150mm 300mm 450mm 600mm
3m 6m
1.5m Horizontal
9.4 FR50VLNema 2 Cable Ladder
50kg metre
45mm
150mm 300mm 450mm 600mm
3m 6m
1m Vertical
9.6 FR60LNema 3 Cable Ladder
60kg metre
Trapeze / Cantilever
84mm
150mm 300mm 450mm 600mm
3m 6m
1.5m Horizontal
9.8 FR70LNema 4 Cable Ladder
70kg metre
Trapeze / Cantilever
102mm
150mm 300mm 450mm 600mm
3m 6m
1.5m Horizontal
9.10 FR100LNema 4 Cable Ladder
100kg metre
Trapeze / Cantilever
102mm 900mm3m 6m
1m Horizontal
9.12 FR150LNema 4 Cable Ladder
150kg metre
Trapeze / Cantilever
102mm
150mm 300mm 450mm 600mm
3m 6m
1m Horizontal
9.14 FR50LT3LT3 Laddertray
50kg metre
Trapeze / Cantilever
40mm
150mm 300mm 450mm 600mm
3m 1m Horizontal
9.16 FR12LT5LT5 Laddertray
13kg metre
Trapeze / Cantilever
75mm150mm 300mm
3m 1.5m Horizontal
9.18 FR20LT5LT5 Laddertray
19.6kg metre
Trapeze / Cantilever
75mm150mm 300mm
3m 1m Horizontal
9.20 FR7BCM Cable Mesh7kg
metreTrapeze / Cantilever
50mm150mm 300mm
3m 1m Horizontal
9.22 FR5C Channel5kg
metreThreaded Rod
45mm 42mm 6m 1.5m Horizontal
Kit components include
- Cantilever or Trapeze
- Splice plate & fasteners (ladder only)
- Hold down (tray only)
- Channel nuts, screws, bolts & fasteners to complete the assembly
www.burndycss.com.auFebruary 2019
Head Office
Western Australia91 - 93 McDowell Street, WelshpoolWestern Australia, 6106Phone 08 9458 1188Fax 08 9458 1182email [email protected]
New South Wales11 Sunblest Crescent, Mt DruittNew South Wales, 2770Phone 02 9832 3377Fax 02 9832 0733email [email protected]
TasmaniaGordon Wood & Co
31 Sunderland Street, MoonahTasmania, 7009Phone 03 6273 4455Fax 03 6273 4734email [email protected]
Queensland
Brisbane Branch161 Jackson Road, Sunnybank HillsQueensland, 4109Phone 07 3219 6108Fax 07 3219 6208email [email protected]
Townsville Branch75 - 81 Toll Street, Mount St JohnQueensland, 4818Phone 1300 287 639Fax 1300 329 669email [email protected]
8029
1 aco
rnde
sign
.com
.au
FIRST CHOICE FOR • TRAY • LADDER • STRUT • HYGROUND • CABLE MESH