fischerBuilding Envelope Solutions
NEW! Market introduction of the FAZ II M6. • SmallestdiameterETAcertified• ThefirstboltanchorM6Option1intheworld
ETA-05/0069ETAG 001
Option 1 for cracked concrete
seismic performance category C1, C2
The interaction of cone and expansion clipsignificantlyincreasesload-bearingcapacityand makes minimum edge distance andaxial spacing possible. For use undermaximumloadrequirements.
Theprotrudinghammer-inpinprotectsthethreadfromdamageduringsetting.
The distinctive edge holds theexpansion clip in position evenwith reinforcement hits, thusensuringsafeinstallation.
Withachoiceofpre-assemblednormalwasher or large washer GS and withwasher HBS in compliance with woodconstructionstandardDIN1052(notpre-assembled).
FBN II Anchor Bolt -Powerfulanchorforultimatedemands
Thedrive-inpinprotectsthethreadfromdamage,andensuresfasterinstallationordismantlingoftheattachments
Lesshammerblowsandminimaltorqueslippagegivesnoticeablyfaster
installations.
Longthreadsincreasetherangeofbaseplatethickness’spossibleallowingstand-offinstallationsandincreasedflexibility.
Standardanchoragedepthachieveslargeload-bearingcapacitiessofewerfixingpointsandsmalleranchorplatesarerequired.
Reducedanchoragedepthreducesthedrillholedepth,minimising
Intallationtime.
FBN II GS with large washer for flexible use in non-cracked concrete.• Thepre-fittedwasherensuresafastinstallation.• The large washer creates a greater supporting
surfacewhichisidealfortimberconstructions.
FAZ II Anchor Bolt -Highperformancesteelanchor
ETA-05/0069ETAG 001-2
Option 1 für gerissenen Beton
Seismische Leistungskategorie C1
• FAZ II available from sizes M6 - M24
• FBN II available from sizes M6 - M20
FAZ II K Anchor Bolt - Shorter VersionTheshorterboltwithreducedembedmentdepthistheeconomicchoicefornumerousapplicationssuchassubstructuresforfaçadesandthefixingofcabletrays.
FAZIIKinzinc-platedorstainlesssteelversionscanbeuseduptoafixturethicknessof20mm.
WithachoiceofnormalwasherorlargewasherGS.
Diamond Drilling Now Approved!
fischer FAZ II A4
Competitor A
Competitor B
FBS II ULTRACUT -Highperformanceconcretescrew
Thecheckinggauge,availableseparately,allowstheouterdiameterofthethreadtobe checked prior to the screw beingreused; this complies with the approvalformultipleuse.
ETA-15/0352EAD 330011-00-0601
Option 1 for cracked concrete
seismic performance category C1, C2
■ Withupto3embedmentdepths,theULTRACUTFBSIImakesitpossibleforthesamescrewtobeusedfordifferentcomponentthicknesses.
■ Expansion-free anchoring (undercut) allows forlowestedgeandaxialclearances.
■ Theassessment(ETAOption1)coverstheuseofsingle-point anchors in crackedandnon-crackedconcrete.
■ The performance categorys Seismic C1 and C2assessment ensures that the strictest of safetystandards has been fulfilled (also with highearthquakespecifications).
■ Thecheckinggaugeallowsamultipleusecoveredbytheapproval.
Benefits
Theapprovalfortheconcretescrewsallowsthescrewtobeunscrewedtwiceforatotalof20mm,toplacemaximal10mmpackingbelowitortoaligntheattachedpart,andthentotightenthescrewagain.
TheULTRACUTFBSIIisavailableindifferentheaddesigns.Countersunkandhexagonalhead(withandwithoutTorxdrive).
Theribsonthelowerheadreleventaccidentalunscrewingoftheanchormakingthesystemmoresecure.
Thespecialthreadgeometrymeansthatthescrewflankscutdeeplyintotheconcreteandallowingforhighloads.Thissavescostsbecauselessanchorpointsandsmallerbaseplatesarerequired.
Thepatentedsaw-toothgeometrycutsquicklyintothesubstrateandcanbeinstalledseveraltimes.
TheshortULTRACUTFBSII,withareducedscrew-indepth,allowsforashortdrillholedepthandfastinstallationwhichmakesitasuitableoptionformanyapplications.
Superbond Resin System-Universalsolutionforcracked&non-crackedconcrete
The fischer Superbond System is a combined capsule and injection resin system for cracked and non-cracked concrete. TheinjectionmortarFISHBandthecapsuleRSBperformthesameaseachotheratthesameanchoragedepths.
System 1: Steel Free choice between FIS A, RGM, RG MI.
Anchor rod FIS A
Anchor rods made of zinc-plated steel grade 5.8, 8.8, stainless steel A4 and highly corrosion-resistant steel.
Internal threaded anchor RG MI
.
Anchor rod RGM
System 2: Resin mortarResin capsule RSB
■ The resin capsule RSB reduces hole cleaning, no brush ing of drill hole required.
■ The RSB has a very short curing time and may be installed from – 30 °CSuperbond injection mortar FIS SB
■ With the Superbond injection mortar FIS SB, anchor rods of sizes M8 to M30 can be installed.
■ The Superbond injection mortar FIS SB is approved for installations up from –15 °C.
Internal threaded anchor , zinc-plated steel & stainless steel A4 for installations flush to the surface
■ FIS Visthefirstuniversalinjectionmortaravailable on the market with the mostETAsforallcommonbuildingmaterials.
■ New:Itcanbeusedincrackedconcretewith guaranteed reliability for practicallyallareasofapplication.
■ The approved alternative to polyesterresinforexternaluse!
Option 1for cracked & non-cracked concrete
FIS V Chemical Resin-Universal injection resin for all building materials
■ FIS V has a number of system approvals, for cracked & non-cracked concrete, masonry and rebar connections. (FIS VW isexcludedfromrebarapproval).
■ Suitableforusewithreinforcementbars■ Temperatureresistanceupto+120°C.■ Partiallyusedcartridgescanbereusedsimplybychangingthestaticmixer.
■ Longshelflife(upto18months,whenstoredcorrectly).■ Compatiblewithawiderangeofprofessionalresindispensers.■ Can be used with extensive, approved system accessories(sleeves&rods)forallbuildingmaterials.
FeaturesBenefits
Maximum security is achieved via a wide range of approved fastening devices such as - anchor rods FIS A, internally threaded anchors RG MI and reinforcement anchors FRA. Approved: Anchor rods FIS A in cracked concrete (M 10 - M 30) and uncracked concrete (M 6 - M 30).
FIS VL 410 C -Forallstandardapplicationsinconcreteandmasonry
Post-installed rebar connection(TR-23)
■ Approved in all common building materials – even crackedconcrete. Reduces the number of products you need whichsafesmoneyandspaceforotherimportanttools.
■ Excellentloadperformanceinallbuildingmaterialsallowsforeconomical use of injection mortar and anchor rods, whichsavestimeandcost.
■ Installation temperature down to –5°C makes it possible tocontinueworkevenatlowtemperaturesandtofinishyourjobontime.
■ AwiderangeofaccessoriesoffersachoiceoffixingsystemsbestsuitedtotheFISVLinjectionmortarfamily.Thisprovidesa broad range of applications offering safe and economicalsolutions.
ETA-10/0352 Cracked and non-cracked concreteETA-15/0263 Solid and hollow masonry, aerated concrete ETA-15/0539 Post-installed rebar connectionsSeveral fire test reports available
Features Benefits■ Approvedincrackedconcrete:
FISA/RGM(M10–M20)■ Approvedinnon-crackedconcrete:
FISA(M6–M30),RGM(M8–M30),RGMI(M8–M20)
■ Inservicetemperature:range:–40°Cupto+120°C
■ Installationtemperature:FISVL:–5°Cupto+40°C
■ Canbeusedindryandwetconcrete■ Approvedforwater-filledholeswith410ml
coaxialcartridges
DHK-Thecost-effectiveplasticinsulationsupportforallconventionalinsulatingboards
▪ Theoptimisedgeometryoftheexpansionsectionensuresalowanchoragedepthandreducestheamountofdrillingrequired.
▪ Flexiblepinsintheplateareaadapttotheinsulatingmaterial,andensureasustainedcontactpressure.
▪ Thesimplehammerset installationallowsforaquick installationprocessandthusreducesworkload.
▪ ThecolouringoftheDHK90meansthatitdoesnotstandoutonblackcladinsulatingmaterialinrear-ventilatedfaçades.
▪ The DHK 45 is suitable for use in pressure-resistant insulatingboardsandreveals.
Features
DHK is ideal for fixing soft and pressure-resistant insulating materials in rear-ventilated façades, such as:▪ Mineral/glasswool▪ PUpanels▪ Lightbuildingboardsmadeofwoodwool▪ Corkboards/coirmatting▪ Polystyrene▪ Foamglasstiles
DIPK -Thecost-effectivedriveanchorwithplasticnail
DHK Is ideal for fixing pressure-resistant insulating materials in façades, such as:▪ Polystyreneboards▪ Lightbuildingboardsmadeofwoodwool▪ Corkboards/coirmatting▪ PUpanels
Features
DHM-fire-protectiontestedmetalinsulationsupportforfire-resistantinsulatingboards
DHM is great for fixing fire-resistant soft or pressure-resistant insulating materials, such as:▪ Mineral/glasswool▪ Lightbuildingboardsmadeofwoodwool▪ Foamglasstiles
Also suitable for:▪ Polystyreneboards▪ Coirmatting
■ Theoptimisedgeometryoftheexpansionsectionensuresa lowanchoragedepthwhichreducestheamountofdrillingrequired.
■ Flexible pins in the plate adapt to the insulating material, andensureasustainedcontactpressure.
■ Thesimplehammerset installationallows foraquick installationprocessandthusreducesworkload.
■ TheDHMinsulationsupportissetinpush-throughinstallationusingahammer.
■ The spring steel expands when hammered into the basematerial.
■ Use the DTM 80 plate (available separately) to fix softinsulatingmaterials.
FeaturesBenefits
▪ The DTM 80 plate forsoftinsulatingmaterialssimplifiesstorageandminimisescosts.
▪ InsulationretainingmetalwasherDTM 80,washer-ø80mm,inside-ø11mm
▪ The glass-fibre-reinforced plastic nail (GRP nail) reduces the heattransmissionandpreventsmarksontheplastersurface.
▪ The simple hammerset installation allows for a quick installationprocessandthusreducesworkload.
▪ The well-proven design with low anchorage depth reduces theamountofdrillingrequired,thusachievingahighlevelofefficiency.
▪ TheDIPKcanbeuseduniversallyinrear-ventilatedcurtainfaçades,aswellasinplasterfaçades.
SXR -Thespecialistframefixingwithshortdrillholedepth
The exceptional performance of the SXR enables it to be used inboth solid and hollow building materials with an anchorage depthof just 50 mm. ▪ TheETAassessmentcoversuseinarangeofsolidandhollowbuilding
materials,andguaranteesasecurefixing.▪ Thespeciallydevelopedcombinationofplugsandscrewsensuresthe
verybesthandling.Theplughasanoticeablehold,makinginstallationmoreconvenient.
▪ Anchoragedepthofjust50mminbothsolidandhollowbuildingmaterials.▪ Theextensiverangewithdiametersof6,8and10mmprovidesachoice
ofplugforeveryfixing.
SXR-L -Thepowerfulproblemsolverwithalongexpansionsleeve
SXRL 14 is approved for applications under compression load and isideal for facade substructures that are mounted at a distance without wall brackets▪ Theuniquegeometryoftheplugensuresthattheretainingforcesareevenly
distributedinthedrillhole.▪ Whentheplugistobesetbelowtheplaster,thelongerribspreventplug▪ rotationduringinstallation.▪ Thevariableanchoragedepthsof50,70or90mmofferspecial
advantagesandhighloadswhenanchoringinaeratedconcrete.▪ TheSXRLwitheffectivelengthsupto290mmprovidestherightplugfor
everyapplication.
FNA II Theinstallation-friendlyhammersetanchoroption1ETAformultiplefixings
▪ The special active principle allows for a simple hammersetinstallationand,therefore,ashortprocessingtime.
▪ Theextremelyshortanchordepthpreventsreinforcementhitsandcreatestheconditionsforatrouble-freeinstallation.
▪ The enhansed expansion clip guarantees a secure hold whenplacedinthedrillholeandpreventsitfallingoutduringoverheadinstallations.
▪ Thesubstantialshaftcross-sectionguaranteesahighload-bearingcapacity,whichoffersanextremelyhighlevelofsafety.
▪ Arangeofdifferentheadtypesallowsforthefixingofwide-rangingfixtures,andfortheidealadaptationtosuittheintendeduse.
▪ TheFNA IIwithnailheadissuitableforpush-throughinstallation.TheFNA II M6issuitableforpre-positionedandpush-throughinstallation.TheFNA II OEandHaresuitableforpre-positionedinstallation.
▪ TheinstalledFNA IInailanchorexpandsautomaticallyunderload.Theconeispulledintotheexpansionclipandexpandsitagainstthedrillholewall.
▪ Available setting tools: FNA S-SBOtoslipontothedrill,FNA S-SDSforseriesinstallationwithadrillinghammer,FNA S-Hforthemanualinstallationofmountingrails.
Benefits Benefits
FeaturesBenefits
▪ A range of head shapes allows for the fixing of wide-ranging fixtures
Cavity FireStop Clad - FCFcl Aproductdesignedtoprotectthebuildingvoidbetweentheinnerandouterconstructionelements.
▪ TestedtoEN1366-4&BS476▪ ClassificationtoEN13501-2,EN13501-1.▪ AirPermeabilitytoEN1026to600Pa.▪ AcousticIsolationtoEN10140to31dB▪ GWPof0%GlobalWarmingPotential.▪ ODPof0%OzoneDepletionPotential.▪ SuperiorLevelofSustainability.▪ EncasedFibreMigrationforAirPlenumUse.▪ Bracketsincludedinthepack.▪ Lifeexpectancyofover25years.▪ ContributestoGreenBuilding▪ Voidsupto590mmwide.
Benefits
▪ FCFclCavityBarriercomprisesofaonepiececloseddimensionstonewoolcore.
▪ Theproductisencasedwithanaluminiumfoilfacewhichprovidesclass‘O’ratingandexhibitsexcellentresistancetosmoke.
▪ TheFCFclprovidesaresilientlateralcompressionwhichisrequiredtoensureatightfit.
▪ DesignedtobeusedinCeilingCavity,SlabEdgeorUnderFloorinstallations
Features
BS476-20
British Standard
Fire|Barr ElastoSeal - FFB-ES Elastomericfireresistantcoatingforconstructionjointandassemblies
▪ Openingsupto600mm(24”)wide.▪ 50%movementcapabilities.▪ Workingtemperaturebetween-10°C▪ to+95°C.▪ Canbesprayorbrushapplied.▪ Airpermeability.▪ Acousticperformance.▪ 80kg/m³stonewoolbase.▪ 2.5mmWFTrequired.
BenefitsfischerFFB-ESElastoSealisaonepartwaterbasedacryliccoatingwhichhasbeendesigned toprovidesmokeandfireprotectiononconstruction joints inbothverticalandhorizontalappliations.Tested to BS EN1366-4 and BS476-20 the FFB-ES is also ETA approvedandCEmarked.Developedforuseon80kg/m³stonewoolbasetheFFB-ESisalsohalogenandsolvent freeandexhibitsexcellent slumpandmovementcharacterestics.Onceapplied,itpreventsthepassageoffireandsmokeandcancontributetotheacousticvalueofastructurebetweenfireratedcompartmentsgivingafireresistanceforupto120EI.
Features
Linearjointapplication Curtainwallapplication
Ideal for Linear joints in constuction elements up to 600mm (24”)Suitablefor:FloortoFloor,WalltoWall,Headofwall,BottomofWall,CurtainWall
Fire|Barr VentiStop - FFB-VS- Designedforuseinhorizontalmodewithincavitiesbetweenventilatedrainscreencladdingandbuildingstructure
FFB-VS is part of the fischer Fire|Barr system for forming fire barriers within building envelope systems.FFB-VScomprisesofanaluminiumfoilfacedstructuralstonewoolsection,withanintegralintumescentstrip,bondedtocovertheexposedface.TestedinaccordancewithBS476-20ithasshownitselfcapableofprovidingupto1hrsfireprotectiononceactivated.Duringnormalservicelife,anairgapofmin25mmismaintainedtoallowventilation.Intheeventofdirectexposuretofire,whensubjectedtoheat,theintumescentstriprapidlyexpandstofilltheairgapwithinthecavity.
Benefits▪ AvailableindifferentwidthsandPrecutunitsforbespokeapplication.▪ Assessedforusewithinopeningsupto450mmspan.▪ Freeofhalogens,asbestos,fibresandsilicaandisnontoxic.▪ Suitableforuseinirregularapplications.▪ Bracketsincludedinpack.▪ Longlifeandeaseofapplicationwithminimumwaste.▪ Allowsformovementofairandmoisture.▪ Encasedfibremigrationforairplenumuse.
Features
Completeassembly Partialassembly
BS476-20:1987
British Standard
BBS EN1366-4: 2006
▪ TestedinMasonry,ConcreteTimber▪ Suitableforapplication:▪ CeilingCavityBarriers▪ UnderFloorCavityBarriers▪ SlabEdgeBarriers
Applications
Suitable for:Concreteslabs,columns&walls,Curtainwallassembles&Stonecladdingetc.
M&E
Solut
ions .
(DM
-V1) .
10/1
7 . d
mc/fi
GB
Elite Fasteners Ltd.Elite Fasteners is a major supplier of fixings, fastenings, sealants and ancillary products specialising in the curtain walling and building envelope markets.We also offer full technical support with in house and on-site testing services. This enables us to provide the safest and most cost effective solutions to meet your needs.The key principles of our business are:• Providing the most cost effective solution to our customers' needs• Ensuring excellent customer service from enquiry right through to delivery.• We are committed to working to the principles enshrined in BS 8539:2012 including the testing requirement’s be they Preliminary Tests to determine the allowable load for a fixing proposed for use in masonry or Proof Tests needed to validate the quality of installation.
fischer fixings UK Ltd. whitely Road, WallingfordOxon, OX10 9AT Tel. 01491827900 · [email protected] www.fischer.co.uk
Elite Fasteners Ltd. Unit 1, Premier Trading Estate, Queen St, Walsall WS2 9NTOffice: 01922 612211 Fax: 01922 636723website: www.elitefasteners.co.uk