Fives Pillard 1
Fives Driving Progress
ANALYSERS & INSTRUMENTS DEPT.
TUNNEL ROAD APPLICATION
I - GAS DETECTORSI I - OPACIMETERS
III - ANEMOMETERS
Fives Pillard 2
VIEW OF OUR SCOPE OF SUPPLY IN TUNNEL
Ignitor's tube
Burner
Gas detector
Anemometers
Opacimeters/Dust monitors
Smoke detector
Fives Pillard 3
Fives Driving Progress
TUNNEL DEPARTMENT
II - OPACIMETERS
OPASTOP 3000 TOPASTOP 3000 S
OPASTOP 3000 ST
Fives Pillard 4
VISUAL & VERSIONSOPACIMETER
GP3000ST GP 3000S GP 3000T
Fives Pillard 5
OPERATING PRINCIPLE
Location In situ In local control room In situ
TechnologyMeasuring by
environmental optical backscatter
Measuring by optical backscatter in a
measuring vessel
Measuring by reflection
Measuring chamber
Measure of dust Continuously
Measure points 1 sample point 2 sample points 1 sample point
Heating system to eliminate fog
- Integrated integrated
Light Modulated light beam by high power LED
Drift compensation against fouling
Not integratedContamination control and automatic drift
compensation against fouling
GP3000ST GP 3000S GP 3000T
TECHNICAL SPECIFICATIONS
OPASTOP
6
GP 3000T GP 3000ST GP 3000S
POWER SUPPLY230V / 115V (+10/-15%) 50HZ
/ 60HZ230V / 115V (+10/-15%) 50HZ
/ 60HZ230V / 115V (+10/-15%) 50HZ /
60HZ
POWER CONSUMPTION 100 VA 50 VA30 VA without turbine
210 with turbine up to 15 metres1,1 kva with turbine up 100 meters
MEASURING RANGE 0 to 16.10-3 K 0 to15.10-3 E/m 0 to15.10-3 K
OPERATING TEMPERATURE
-20°c TO 50°C -20°c TO 50°C -20°c TO 50°C
STORAGE TEMPERATURE
-20°c TO 60°C -20°c TO 60°C -20°c TO 60°C
HOUSING Stainless 304 L Stainless steel 316 L Stainless steel 316 L
PROTECTION IP 65 IP 65 IP 54
DESIGN Modular design Compact cabinet Compact cabinet
ANALOG OUTPUT 4-20mA on750 Ohms 4-20mA on750 Ohms4-20mA on750 Ohms
LOGIC OUTPUT2 threshold relays,1 general
fault relay
2 threshold relays/1 alarm relay/1 extraction fan
command relay
2 threshold relays,1 general fault relay,2 solenoid control relays
WEIGHT 13Kg 10Kg 6Kg
OPASTOP GP 3000ST
OPASTOP GP3000ST
Measuring by reflection, in situ
Modulated light beam by high power LED
Automatic drift compensation against fouling
Stainless steel 316L
Heating system to eliminate fog (50w)
GP3000 S
OPASTOP GP3000S
Measuring by extraction sampling
Modulated light beam by high power LED
Automatic drift compensation against fouling
Possibility of managing two sample points
Heating system to eliminate fog (50w)
OPASTOP GP3000S & GP3000 ST: presentation
Coffret de mesure
Entrée (Tube aspiration)
Sortie (vers turbine d'aspiration)
Filtre
Capteur(Chambre de mesure)
Carte électronique principale
Suction inlet (with protection against water splash)
Measuring panel
Main electronics board
Sensor(measuring chamber)
Discharge
Filter
GP 3000S GP 3000 ST
Coffret de mesure
Aspiration(avec protection contreprojection eau)
RefoulementFiltre
Capteur(Chambre de mesure)
Carte électronique principale
Ventilateur
Discharge
Air fan
Filter
Suction inlet(with protection against water splash)
Measuring panel
Main electronics board
Sensor(measuring chamber)
GP3000 T
OPASTOP GP3000T
Measuring by reflection, in situ
Modulated light beam by high power LED
Single sensor integrated in electronic panel
Modular design
OPASTOP GP3000T: définition of the system
Light emitter
Measuring unit (Receiver)
A cone of modulated light is emitted from a light source module.
A receiver positioned at 90° to the light source unit receives part of the reflected light from the suspended particles.
A sweeping air system enables the fibre optic tips to stay clean.
OPASTOP GP3000T: définition of the system
Main Circuit Board
MainElectricSupply
Air treatment unit
Filter
Sweeping air inlet
Measuring unit(Receiver)
Light generator(Emitter)
Measuring Panel
Air Pump
Ambiant air inlet
Outlet f or treated air
100 VA
250 VA
Electric supply
Phase (L1)
Earth ( )
Neutral (N)
Panel terminal forair treatment
PROTECTION & CERTIFICATION
Protection rating (as per EN60529) : IP65
Protection against dust
Hermetically sealed against dust
Protection against water spray
Water sprayed by a jet on the protection cell, from whatever direction, will have no detrimental effect.
13
VIEW OF FITTED PRODUCTS
14
MAINTENANCE
Calibration device
Maintenance operations
· The general appearance of the wiring in the cabinet,· The cleanliness of electronic circuits (de-dusting with power off)· The condition of the panel door seal,· The condition of the sensor filter· The condition of the fan. Filter replacement