FLASH.Free-Electron
Laserin Hamburg
Overview and Status of the Standard Electron Beam Diagnostics at FLASH
N. Baboi, DESYfor the Diagnostics Team
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 2
FLASH.Free-Electron Laser
in HamburgContents
>Overview of standard beam diagnostics in FLASH1 and FLASH2 General characteristics
> Beam monitors Charge Monitors
Position Monitors
Size Monitors
Loss Monitors
Not all monitor types covered by this talk
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 3
FLASH.Free-Electron Laser
in HamburgOverview of Electron Beam Diagnostics in FLASH
FLASH1 FLASH2
Charge Toroids 12 5
Dark Current Monitor 1
Faraday Cups 3
BPMs 6 33
Transverse Size
OTR-Screens ~30
Scintillating-Screens 1 7
Wire scanners (MDI) 10
Wire scanners (Zeuthen) 9
Transverse Position
Button-BPMs 26 12
Stripline-BPMs 33 4
Cold Cavity BPMs 6
Cavity BPMs 17
HOM-based monitors 39
Beam Loss BLMs >70 ~55
Cherenkov Fibers 2 1
Beam Halo Monitors 1x4 1x4
Ionization Chambers 4 4
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 4
FLASH.Free-Electron Laser
in HamburgGeneral Characteristics
>General Deliver bunch by bunch measurements, with few exceptions
> FLASH1 Most designed for TTF2, for charges of 1nC and higher
Electronics: VME-based, ADCs with 1MHz
> FLASH2 Most designed for the E-XFEL
Make use of synergies given by the similar time lineSome have been designed specially for FLASH(2)
or have a temporary solution Generally based on MTCA-technology
9 MTCA crates for diagnostics installed at FLASH2 Designed for lower charge
N. Baboi, IBIC’14, THIXB1
J. Feldhaus, D. Nölle, EPAC2004, p. 262
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 5
FLASH.Free-Electron Laser
in Hamburg
Charge Monitors / Toroids
FLASH1
> All signals go to VME and uTCA-system
3GUN and 10DBC2 have new front-end (amplifier & filter, like in FLASH2)
FLASH2
> Temporary solution Low-gain front-end channel
CAT cables
(E-XFEL type under tests
M. Werner, IBIC’14, WEPF02)
Charge Monitors: Toroids
W
W
W
W
+
+
+ Front-end
Adapter RTM RTM SIS8900
AMC SIS8300
AMP-200ADC peak
ADC base
VME(Fl1)
uTCA (Fl1&2)
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 6
FLASH.Free-Electron Laser
in Hamburg
►
Charge Monitors: Toroids (2)
Resolution of charge monitors along FLASH(1) (~ 0.4 nC) o FLASH-type (VME)
o FLASH2-type (MTCA) old amplifier
O FLASH2-type with new amplifier
► Dark current monitor
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 7
FLASH.Free-Electron Laser
in HamburgToroid Protection System (TPS)
5 MeV 150 MeV 1250 MeV
Bunch Compressors
450 MeV
Accelerating StructuresRF Stations
LasersRF Gun
Soft X-ray UndulatorssFLASH
FEL Experiments
Photon Diagnostics
Beam Dump
THzFLASH1
FLASH2
TPS 0 TPS 1
TPS 2
A. Hamdi, DIPAC 2007, p. 349
> Temporary solution using 3 TPS modules designed for FLASH
(not yet commissioned)
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 8
FLASH.Free-Electron Laser
in HamburgCharge Monitors: Dark Current Monitor
Dark current
Bunch
7DBC2, 32m
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 9
FLASH.Free-Electron Laser
in Hamburg
>Designed by INFN
> Some camera-PCs have to be reset/restarted from time to time
>Recently had to readjust 3 stations in DBC2
Difficult due to missing fine adjustment
2 are adjusted only for a magnification of 1
> Emittance tool
Screens at FLASH1
A. Cianchi, EPAC2004, p. 2619
23.09.2014, 13:42
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 10
FLASH.Free-Electron Laser
in HamburgScreens at FLASH2
BEAM
Op
tics
Axi
s
> Scintillator based (LYSO:Ce), spatial suppression of COTR
>Optics: Look under 45 deg
Uses “Scheimpflug´s” principle to extend depth of field
> 10 µm resolution required single bunch, streaked
>Demonstrated at FLASH1
200µm thick LYSO Screen (ON-Axis)2 half 200µm thick LYSO Screens (OFF-Axis)
Dot Grid Target(spot Ø .50mm)
C. Wiebers, IBIC2013, WEPF03
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 11
FLASH.Free-Electron Laser
in HamburgScreens at FLASH1 (2)
> Fully commissioned
FLASH2
FLASH1
1FL2SEED4
1FL2SEED6 1FL2SEED7
1FL2SEED5
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 12
FLASH.Free-Electron Laser
in Hamburg
>One horizontal and one vertical fork, each with 3 wires
Used also for cross-calibration of BPMs
> Tool for profile scans and emittance
Wire Scanners: Zeuthen Type
P. Castro, DIPAC 2005, p. 205
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 13
FLASH.Free-Electron Laser
in Hamburg
>One fork placed at 45deg with horizontal, vertical and diagonal wire
Several WS use one detector
Also possible to read signals from BLMs, with some change in the beam profile
Some have some readout/timing problems, now under work
Jddd panels to be updated
Wire Scanners: MDI/CERN Type
M. Werner, DIPAC 2001, p. 139
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 14
FLASH.Free-Electron Laser
in Hamburg
> Button BPMs, stripline BPMs, cold cavity BPMs, button BPMs inside undulators
BPMs in FLASH1
~0.35 nC
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 15
FLASH.Free-Electron Laser
in HamburgBPMs in FLASH2: Cavity BPMs
>Cavities Dipole + reference resonator
3.3 GHz, low Q (about 70)
17 installed between undulators – 10 mm pipe
No individual tuning
>Readout (PSI) MBU (Modular BPM Unit) with 2 RFFE for 2 cavity BPMs
Up to 4 MBUs connected to 1 DAMC2 interface board
Timing: decoding timing protocol via fiber in MBU
>Resolution requirement 2 mm rms for 0.1-1 nC and within ± 0.5 mm
(1 mm at XFEL, but longer cables at FLASH2)
M. Stadler, IBIC’14, WEPD12
B. Keil, IBIC’14, WEPD11
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 16
FLASH.Free-Electron Laser
in Hamburg
> BPMs in FLASH2 Difference between expected and
measured position with Gaussian fit
BPMs in FLASH2: Cavity BPMs: Resolution
> Test BPMs in FLASH1 0.5 mm rms for 0.24 nC bunch charge
and 0.5 mm bunch offset
Resolution of various FLASH1-BPMs (designed for 1 nC)
~0.35 nCpreliminary
D. Lipka, IBIC’14, TUPF07
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 17
FLASH.Free-Electron Laser
in Hamburg
BPMs in FLASH2: Cavity BPMs: Charge
>Charge resolution for 100 pC bunch charge < 0.2 pC rms
D. Lipka, IBIC’14, TUPF07
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 18
FLASH.Free-Electron Laser
in HamburgBPMs in FLASH2: Button and Stripline BPMs
> Low Charge BPMs (LCBPM) electronics Name chosen in contrast to system designed
for FLASH for charges of 1nC and higher
Designed for FLASH2 (and to be installed in all FLASH)
Button or
Strip-line BPM
Delay ~100ns
Broadband
RF Combiner
RF cable 3/8“
Length < 80m
Signal of horizontal plane, delay line: ~100ns
TYPICAL SIGNALS FROM BUTTON/STRIP-LINE BPM
B. Lorbeer, IBIC’14, TUPF08F. Schmidt-Föhre, IPAC’14, THPME117
S. Vilcins, IBIC’14, TUPF11
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 19
FLASH.Free-Electron Laser
in Hamburg
BPMs in FLASH2: Button and Stripline BPMs: LCBPM
Rear Transition Module (RTM)
180mmx162mm
Compatible with the MTCA.4
for physics standard
RF Front-EndMicroTCA crate
X-ChannelY-Channel100ns
Crate used for the tests includes:• management carrier hub (MCH)• hard disk (HD), processor (CPU) • Digitizer SIS8300• timing module x2timer
RTM Analog Output Signals
G=38dB
Att.>60dB
Peak Detector
5 BPMs/crate
Front Side
Back Side
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 20
FLASH.Free-Electron Laser
in Hamburg
BPMs in FLASH2: Button &Stripline BPMs: Operation
RMS at q=36 pC, 200 pulses (incl. beam jitter)
Server Panel for Firmware Adjustment
BPM Expert Panel
Strip-Line BPM Button BPM
sy = 22 mm sy = 39 mm
bunch charge 0.1-1 nC
bunch spacing ≥222 ns
maximum macro-pulse repetition rate 25 Hz
beam pipe diameter 40.5 mm
single bunch resolution 50 μm
Averaged RMS resolution over 1000 bunches of identical train 10 μm
Range for max. resolution +/- 3 mm
Operation range with reasonable signal +/-10 mm
Requirements (from XFEL requirements)
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 21
FLASH.Free-Electron Laser
in HamburgHOM-based Position Monitors
>Monitor dipole, beam position correlated, signals excited in the accelerating cavities
Amplitude shows the beam alignment in the cavities, which influences the (transverse) beam quality
Available in ACC1 (3 cavities), ACC39 and ACC2-5
Display only signal envelope
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 22
FLASH.Free-Electron Laser
in HamburgBeam Loss Monitors in FLASH1
Cannot distinguish between losses from FLASH1 and FLASH2 pulses
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 23
FLASH.Free-Electron Laser
in HamburgBeam Loss Monitors in FLASH2
>Detector Scintillator or fused silica
(rod or fiber)
PMT: HV voltage (~500 V) generated by Cockcroft-Walton multiplier on board mounted at PMT
Scintillators and mechanics built by IHEP, Protvino (60 for FLASH2)
> Electronics MTCA-based with low latency interface with MPS
> Alarms algorithms Single bunch
Multi-bunch
Integration
OR of comparator and FPGA alarms
Readout Electronics
Power control
PMT& HV
Scintillator
Beam Loss Monitor
e,γ,n0
Alarm (to MPS)
A. Kaukher, BIW 2012, p. 35
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 24
FLASH.Free-Electron Laser
in HamburgBeam Loss Monitors in FLASH2: Status
>Calibrated single and multi-bunch alarm
> Integration alarms to be calibrated
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 25
FLASH.Free-Electron Laser
in Hamburg
Dump Loss Monitors in FLASH1 & FLASH2: BLMs and Ionization Chambers
> BLMs based on quarz-fiber + Ionization Chambers (air filled cables) along last 2m of beam line
> VME/uTCA electronics
beam
FLASH1
N. Baboi, BIW 2010, p. 420
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 26
FLASH.Free-Electron Laser
in Hamburg
Dump Loss Monitors: Beam Halo Monitors (FLASH1 & FLASH2)
> Installed behind dump vacuum window 8 sensors: 4 Diamond + 4 Sapphire
> VME-based in FLASH1
> uTCA-based in FLASH2 Basically same electronics and
firmware as FLASH2 BLMs
Under commissioning
FLASH1
A. Ignatenko, IPAC 2012, p. 816
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 27
FLASH.Free-Electron Laser
in HamburgAcknowledgement
>Many people contributed to the work and this talk R. Neumann, D. Lipka, N. Wentowski, Z. Pisarov, M. Werner, J. Lund-Nielsen,
B. Lorbeer, A. Kaukher, T. Wamsat, A. Ignatenko, F. Schmidt-Föhre, K. Honkavaara, H. Tiessen, B. Michalek, R. Zahn, B. Keil, D. Nölle, O. Hensler, G. Marinkovic, K. Knaack, J. Schwarz, J. Liebing, H. Sokolinski, G. Kube, C. Wiebers, M. Felber, R. Zahn, S. Vilcins, J. Kruse, D. Renner, M. Felber, S. Schreiber, M. Holz, M. Pelzer, A. Ziegler, M. Hoeptner, H. Sokolinski, M. Stadler, M. Wendt, I. Krouptchenkovand many others
Thank you !
Nicoleta Baboi | Electron Beam Diagnostics at FLASH | FLASH Seminar | DESY, Hamburg | Nov. 11, 2014 | Slide 28
FLASH.Free-Electron Laser
in HamburgOther Electron Beam Monitors in FLASH2
> Loss monitors Cherenkov fibers along undulators (not for XFEL)
> Beam Compression Monitors
> Beam Arrival Monitors
>Coherent Transition Radiation monitors
C. Behrens, IPAC’10, p.912
A. Angelowski, IBIC’14, MOPD25
S. Wesch, BIW 2012, THAP01