Type Indoor, Wall hung, Fully Condensing
Fuel Preset for NG / LP convertible
Minimum / Maximum Input (Btu/h) 30,000 / 199,950
Combustion efficiency 98%
Thermal Efficiency 94%
Energy factor 0.93
Dimensions H X W X D (inches) 25.9 X 17.5 X 14.2 (3.7 cu. ft)
Weight (lbs) 90
Water Inlet / Outlet Connection 3/4" NPT
Gas Inlet Connection 3/4" NPT
Minmum Flow Rate .6 GPM
Ignition Electronic Spark Ignition
Venting TypeDirect Vent (2 pipe - intake &
exhaust), Power vent (1 pipe -
exhaust only)
Venting MaterialsSch. 40 PVC, Sch. 40 CPVC,
Polypropylene, Stainless Steel
Max 3” Vent Length - Single Pipe / Power Vent 200 ft, deduct 5 ft per 90° elbow
Max 3” Vent Length - Two pipe / Direct Vent 100 ft, deduct 5 ft per 90° elbow
Max 2” Vent Length - Single Pipe / Power Vent
(2” not allowed at elevations above 4,000 ft)26 ft, deduct 5 ft per 90° elbow
Max 2” Vent Length - Two Pipe / Direct Vent
(2” not allowed at elevations above 4,000 ft)21 ft, deduct 5 ft per 90° elbow
Common Venting Yes
Safety
Flame Rod, Thermal Fuse, Overheat
Prevention Device, Fan Speed
Monitor, Flue Temperature Monitor,
Blocked Vent Detector, Water Leak
Detector, Water Shut Off Valve,
2X10A Fuse, Dual Flame Sensing
Water Pressure Min / Max (PSI) 30 / 150
NG/LP- Minimum Static Gas Pressure 1/2" 5" (non-corrugated, black iron)
NG/LP- Minimum Static Gas Pressure 3/4" 2.5" (non-corrugated, black iron)
NG/LP - Maximum Static Gas Pressure 14”
Gas Pressure for Adjustments 8" for NG, 11" for LP
Electrical 120V AC, 60 Hz
Power Consumption500W (Max 4.2 Amps), 8W
(Standby)
Cascading Masterless, 10 units
Heat exchanger Expandable, Stainless 316L
Warranty (with recirculation) Heat Exchanger: 6 years, Parts: 5
years, Labor: 1 year
Parameters FlexFlame94
Hot water out
T & P Relief ValveStorage Tank
Aquastat
Cold water in
Circulator
Isolation and Drain Kit Recommended
Instantaneous Hot Water Production Rate Per HeaterGas Data
Input GPM @ GPM @ GPM @
Size BTU's/hr 60° Rise 80° Rise 100° Rise
FlexFlame94 199,950 6.3 4.7 3.8
Hourly Recovery Rate for Systems Circulating with a Storage TankGas Data Storage Sized for
Input Tank GPH @ GPH @ GPH @ # of Washers
Size BTU's/hr Gallons 60° Rise 80° Rise 100° Rise Approx*
FlexFlame94-1 199,950 X 1 80 378 282 228 14FlexFlame94-2 199,950 X 2 119 756 564 456 28FlexFlame94-3 199,950 X 3 119 1134 846 684 42FlexFlame94-4 199,950 X 4 200 1512 1128 912 56* All systems should be sized by NATCO based on detailed job information. Call 1-888-OK-NATCO.
Gallons Per Minute at Temperature Rise
Gallons per Hour at Temperature Rise
Note: Systems with 2 heaters have 2 times the instantaneous hot water production rate, etc.