Date post: | 07-Mar-2016 |
Category: |
Documents |
Upload: | stephanie-sanchez |
View: | 235 times |
Download: | 2 times |
77
Description
Multi-conductor Cable, two, three or four flexible soft copper conductorspolyolefin insulated, twisted and external PVC Rubber jacket
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationPolyolefin (75° C)
JacketFlame retardant Polyvinyl Chloride with content of rubber
Characteristics
Operating Temperature75° C.Operating Voltage600 V.
Applications
Hard Service Cord for equipment and portable tools, special for factories, scenes anddisplay cabinets. Open wiring installation, in portable extensions with terminals.
By being of common use, it can be used like portable cord, control and power cable.Easy handling and flexibility in reduced spaces.
Specifications
CENTELSA ST-C Cables are manufactured under the following standards:
UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire.CENTELSA Specifications for ST-C Cables
Type ST-C CablesExtra Hard Service Thermoplastic Insulated, C: Common Use
8
Certifications
CENTELSA ST-C Flexible cords are certified by:CIDET (Colombia). Cert. No. 02005, according to RETIE (Colombian TechnicalCode of Electrical Installations) requirements
ColorsConductors identification: 2, black-white; 3, black-white-green; 4, black-white-red-green. Black colored Jacket.
PackagingWood Reels. Reel lengths between 500 m and 2500 m.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
9
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 75°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4. Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Flexible Cord Type ST-C 600V, 60oC (International System Unit)Extra Hard Service Thermoplastic Insulated, C: Common Use
Standards: UL 62, NTC 2356 and CENTELSA specifications for ST-C cables
0.64
0.76
0.76
0.76
0.76
0.76
1.14
1.52
1.52
1.52
0.254
0.254
0.254
0.254
0.254
0.254
0.254
0.254
0.254
0.254
10
16
26
41
65
104
168
266
420
665
0.51
0.81
1.32
2.08
3.29
5.27
8.51
13.48
21.28
33.70
0.97
1.23
1.51
1.98
2.52
3.21
3.66
4.77
6.00
7.56
6.266.627.237.267.708.437.828.309.118.769.32
10.249.84
10.4812.3212.0012.7414.7815.2516.1918.7720.0521.2823.3323.2924.7127.0826.4128.0730.85
0.760.760.760.760.760.760.760.760.760.760.760.760.760.761.141.141.141.521.521.522.032.032.032.032.412.412.412.412.412.41
35.435.435.422.122.122.113.613.613.68.638.638.635.455.455.453.403.403.402.112.112.111.331.331.33
0.8430.8430.8430.5320.5320.532
2
10
13
18
25
30
40
55
70
95
50597069829986
104127113139171152190255231288382380476630635790976902
11331407125416002003
-
7
10
15
20
25
35
45
60
80
20
18
16
14
12
10
8
6
4
2
234234234234234234234234234234
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
JACKETTHICKNESS
(mm)
OVERALLDIAMETER
(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mm)
COPPER CONDUCTORCONDUCTORS
No.
10
Notas: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 75°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4. Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
25
30
30
30
30
30
45
60
60
60
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10
16
26
41
65
104
168
266
420
665
1.00
1.60
2.60
4.10
6.50
10.40
16.80
26.60
42.00
66.50
38
48
59
78
99
126
144
188
236
298
246261284286303332308327359345367403387413485472502582600637739789838919917973
1066104011051215
303030303030303030303030303045454560606080808080959595959595
10.810.810.86.746.746.744.154.154.152.632.632.631.661.661.661.041.041.04
0.6420.6420.6420.4060.4060.4060.2570.2570.2570.1620.1620.162
2
10
13
18
25
30
40
55
70
95
3339474655675870857693
115102128172155194256256320423427531656606761945843
10751346
-
7
10
15
20
25
35
45
60
80
20
18
16
14
12
10
8
6
4
2
234234234234234234234234234234
Flexible Cord Type ST-C 600V, 60oCExtra Hard Service Thermoplastic Insulated, C: Common Use
Standards: UL 62, NTC 2356 and CENTELSA specifications for ST-C cables
STRANDDIAMETER
(mils)
STRANDSSIZEAWG SECTION
(kcmil)
INSULATIONTHICKNESS
(mils)
JACKETTHICKNESS
(mils)
OVERALLDIAMETER
(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mils)
COPPER CONDUCTORCONDUCTORS
No.
11
Description
Multi-conductor Cable, two, three or four flexible soft copper conductors polyvinylchloride (PVC) insulated, twisted and external PVC jacket
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)
JacketFlame Retardant Polyvinyl chloride (PVC 60° C)
Characteristics
Operating Temperature60° C.Operating Voltage600 V.
Applications
Hard Service Cord for equipment and portable tools, special for factories, scenes anddisplay cabinets. Open wiring installation, in portable extensions with terminals.
Specifications
CENTELSA ST Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire.
Certifications
CENTELSA ST Flexible cords are certified by UL, File E203934
Flexible Cords Type STExtra Hard Service Thermoplastic Insulated
12
ColorsConductors identification: 2, black-white; 3, black-white-green; 4, black-white-red-green. Black colored Jacket.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
13
Flexible Cords Type ST 600V, 60oC (International System Unit)Extra Hard Service Thermoplastic Insulated
Standard: UL 62, NTC-2356 Flexible Cord and Fixture Wire.
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4. Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
1.14
1.14
1.14
1.52
1.52
1.52
1.52
0.254
0.254
0.254
0.254
0.254
0.254
0.254
41
65
104
168
266
420
665
2.08
3.29
5.27
8.51
13.48
21.28
33.70
1.98
2.52
3.21
3.66
4.12
6.72
8.58
12.9113.5814.7114.7715.5316.8016.1517.0218.4719.4020.4523.0121.1022.2324.9027.0928.6231.9631.5933.4137.15
2.032.032.032.412.412.412.412.412.412.792.793.183.183.183.563.563.563.943.943.944.32
8.638.638.635.455.455.453.403.403.402.112.112.111.331.331.33
0.8430.8430.8430.5320.5320.532
18
25
30
40
55
70
95
210244290283331394357425512535644818692851
1082108813271674154118992388
15
20
25
35
45
60
80
14
12
10
8
6
4
2
234234234234234234234
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
JACKETTHICKNESS
(mm)
OVERALLDIAMETER
(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mm)
COPPER CONDUCTORCONDUCTORS
No.
14
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4.Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
45
45
45
60
60
60
60
10.0
10.0
10.0
10.0
10.0
10.0
10.0
41
65
104
168
266
420
665
4.10
6.50
10.40
16.80
26.60
42.00
66.50
78
99
126
144
162
265
338
508535579582611661636670727764805906831875980
106611271258124413151463
808080959595959595
110110125125125140140140155155155170
2.632.632.631.661.661.661.041.041.04
0.6420.6420.6420.4060.4060.4060.2570.2570.2570.1620.1620.162
18
25
30
40
55
70
95
141164195190222265240286344359433550465572727731892
1125103612771605
15
20
25
35
45
60
80
14
12
10
8
6
4
2
234234234234234234234
Flexible Cords Type ST 600V, 60oCExtra Hard Service Thermoplastic Insulated
Standard: UL 62, NTC-2356 Flexible Cord and Fixture Wire.
STRANDDIAMETER
(mils)
STRANDSSIZEAWG SECTION
(kcmil)
INSULATIONTHICKNESS
(mils)
JACKETTHICKNESS
(mils)
OVERALLDIAMETER
(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mils)
COPPER CONDUCTORCONDUCTORS
No.
15
Description
Multi-conductor Cable, two, three or four flexible soft copper conductors polyvinylchloride (PVC) insulated, twisted and external PVC jacket
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)JacketFlame Retardant Polyvinyl chloride (PVC 60° C)
Characteristics
Operating Temperature60° C.Operating Voltage300 V.
Applications
Junior Hard Service Cord for industrial, commercial and residential equipment. Openwiring installation, in portable extensions with terminals.
Specifications
CENTELSA SJT Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire.
Flexible Cords Type SJTJunior Hard Service Thermoplastic Insulated
16
Certifications
CENTELSA SJT Flexible cords are certified by UL, File E203934
ColorsConductors identification: 2, black-white; 3, black-white-green; 4, black-white-red-green. Black colored Jacket.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
17
Flexible Cords Type SJT 600V, 60oC (International System Unit)Junior Hard Service Thermoplastic Insulated
Standard: UL 62, NTC-2356 Flexible Cord and Fixture Wire.
Flexible Cords Type SJT 600V, 60oCJunior Hard Service Thermoplastic Insulated
Standard: UL 62, NTC-2356 Flexible Cord and Fixture Wire.
0.76
0.76
0.76
0.76
1.14
0.254
0.254
0.254
0.254
0.254
16
26
41
65
104
0.81
1.32
2.08
3.29
5.27
1.23
1.51
1.98
2.52
3.21
7.267.708.437.828.309.118.769.32
10.2410.6211.2612.3214.3515.2216.67
0.760.760.760.760.760.760.760.760.761.141.141.141.521.521.52
22.122.122.113.613.613.68.638.638.635.455.455.453.403.403.40
10
13
18
25
30
69829986
104127113139171169208255298363445
7
10
15
20
25
18
16
14
12
10
234234234234234
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4. Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Two current carrying conductors.4. Three current carrying conductors.5. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
30
30
30
30
45
10.0
10.0
10.0
10.0
10.0
16
26
41
65
104
1.60
2.60
4.10
6.50
10.40
48
59
78
99
126
286303332308327359345367403418443485565599656
303030303030303030454545606060
6.746.746.744.154.154.152.632.632.631.661.661.661.041.041.04
10
13
18
25
30
4655675870857693
115114140172200244299
7
10
15
20
25
18
16
14
12
10
234234234234234
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
JACKETTHICKNESS
(mm)
OVERALLDIAMETER
(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mm)
COPPER CONDUCTORCONDUCTORS
No.
STRANDDIAMETER
(mils)
STRANDSSIZEAWG SECTION
(kcmil)
INSULATIONTHICKNESS
(mils)
JACKETTHICKNESS
(mils)
OVERALLDIAMETER
(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mils)
COPPER CONDUCTORCONDUCTORS
No.
18
Description
Multi-conductor Cable, two, three or four flexible soft copper conductorspolyvinyl chloride (PVC) insulated, twisted and external PVC jacket
Construction
ConductorFlexible soft copper conductor, Class M stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)JacketFlame Retardant Polyvinyl chloride (PVC 60° C)
Characteristics
Operating Temperature60° C.Operating Voltage300 V.
Applications
Service Cord, vacuum cleaner cord computers and similar equipments.Open wiring installation, in portable extensions with terminals.
Specifications
CENTELSA SVT Cables are manufactured under the followingstandards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsUL 62, NTC-2356 Flexible Cord and Fixture Wire.
Flexible Cords Type SVTService Vacuum-cleaner cord, Thermoplastic Insulated
19
Certifications
CENTELSA SVT Flexible cords are certified by UL, File E203934
ColorsConductors identification: 2, black-white; 3, black-white-green; 4, black-white-red-green. Black colored Jacket.
Note: Other configurations, sizes, colors and length not specified herein are availableupon request.
Flexible Cord Type SVT 300V 60°C (International System Unit)Service Vacuum-cleaner cord, Thermoplastic Insulated
Standard: UL 62, NTC-ICONTEC 2356. Flexible and Fixture Wire
0.38
0.38
0.160
0.160
41
65
0.82
1.31
1.166.766.001.486.766.00
5.605.916.436.246.607.20
0.760.760.760.760.760.76
22.122.122.113.613.613.6
10
13
465668627694
7
10
18
16
234234
Notes: 1. Fourth conductor is used as grounding conductor.2. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.3. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.4. Two current carrying conductors.5. Three current carrying conductors.6. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Flexible Cord Type SVT 300V 60°CService Vacuum-cleaner cord, Thermoplastic Insulated
Standard: UL 62, NTC-ICONTEC 2356. Flexible and Fixture Wire
15
15
6.3
6.3
41
65
1.63
2.58
46
58
220233253246260284
303030303030
6.746.746.744.154.154.15
10
13
313846415163
7
10
18
16
234234
Notes: 1. Fourth conductor is used as grounding conductor.2. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.3. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.4. Two current carrying conductors.5. Three current carrying conductors.6. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
20
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
JACKETTHICKNESS
(mm)
OVERALLDIAMETER
(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mm)
COPPER CONDUCTORCONDUCTORS
No.
STRANDDIAMETER
(mils)
STRANDSSIZEAWG SECTION
(kcmil)
INSULATIONTHICKNESS
(mils)
JACKETTHICKNESS
(mils)
OVERALLDIAMETER
(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
AMPACITY 2
(A) 3AMPACITY 2
(A) 4DIAMETER
(mils)
COPPER CONDUCTORCONDUCTORS
No.
21
Description
Two copper flexible copper conductor, paralleled and PVC insulated.
Construction
Flexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)Integral insulation with separation membrane, and polarization ridges in oneconductor.
Characteristics
Operating Temperature60° C.Operating Voltage300 V. (600V optional)
Applications
Service Cord, for portable electrical devices. Open wiring installation, in portableextensions with terminals.
Specifications
CENTELSA SPT Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire.CENTELSA Specifications for SPT-C Cables
Certifications
CENTELSA SPT-C Paralleled cords are certified by:CIDET (Colombia). Cert. No. 02004, according to RETIE (Colombian Technical Codeof Electrical Installations) requirements
Parallel Cord Type SPT-CParallel Cord, Thermoplastic Insulated
ColorsWhite, grey brown and black. Optional with red strip at one conductorfor polarization indication.
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
22
23
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Paralleled Cord Type SPT-C 300V, 60°C (International System Unit)Parallel Cord, Thermoplastic Insulated
Standards: UL 62, NTC 2356 and CENTELSA specifications for SPT-C cables
Paralleled Cord Type SPT-C 300V, 60°C)Parallel Cord, Thermoplastic Insulated
Standards: UL 62, NTC 2356 and CENTELSA specifications for SPT-C cables
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
10.010.010.010.010.010.0
71016264165
0.701.001.602.604.106.50
303848597899
202025252525
91219263856
15.110.66.614.072.581.63
XXXXXX
-2
10131825
222222
XXXXXX
222018161412
7382
102113131153
147163204226263305
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
EXTERNALDIMENSIONS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C 1
(ohm/km)
AMPACITY 2
(A)DIAMETER
(mm)
COPPER CONDUCTOR
0.2540.2540.2540.2540.2540.254
71016264165
0.350.510.811.322.083.29
0.760.971.231.511.982.52
0.510.510.640.640.640.64
141728395784
49.634.721.713.38.465.34
XXXXXX
-2
10131825
222222
XXXXXX
222018161412
1.862.072.592.873.343.88
3.724.145.175.736.677.75
STRANDSSIZEAWG STRAND
DIAMETER(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
EXTERNALDIMENSIONS
(mils)
APPROX.TOTAL
WEIGHT(lb/kft)
DCRESISTANCE
AT 20°C 1
(ohm/kft)
AMPACITY 2
(A)DIAMETER
(mils)
COPPER CONDUCTOR
24
Description
Two copper flexible copper conductor, paralleled and PVC insulated.
ConductorFlexible soft copper conductor, Class M stranded for SPT-1 and SPT-2Flexible soft copper conductor, Class K stranded for SPT-3
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)Integral insulation with separation membrane, and polarization ridgesin one conductor.
Characteristics
Operating Temperature60° C.Operating Voltage300 V.
Applications
SPT-1: Portable lamps feeders, fans, radios, clocks, householdappliances and office equipment.SPT-2: Same as above, stereo and video devicesSPT-3: Freezers, coolers, air conditioning equipment, dish washingmachines, waste disposers and office equipment.
Specifications
CENTELSA SPT-1, SPT-2 and SPT-3 Paralleled Cords are manufacturedunder the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible Cords
Paralleled CordType SPT-1 SPT-2 SPT-3Parallel Cord, Thermoplastic Insulated
25
UL 62, NTC-2356 Flexible Cord and Fixture Wire.
ColorsWhite, grey, brown and black.
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein are availableupon request.
26
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Paralleled Cords Type SPT-1 SPT-2 SPT-3 300V, 60°CParallel Cord, Thermoplastic Insulated
Standard: UL 62, NTC 2356. Flexible and Fixture Wire
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Paralleled Cords Type SPT-1 SPT-2 SPT-3 300V, 60°C(International System Unit)Parallel Cord, Thermoplastic Insulated
Standard: UL 62, NTC 2356. Flexible and Fixture Wire
0.1600.1600.1600.1600.2540.2540.2540.2540.254
2641416516264165
104
0.520.820.821.310.811.322.083.295.27
0.921.161.161.481.231.511.982.523.21
0.760.761.141.141.521.522.032.412.79
172436505168
115177268
33.621.321.313.521.713.38.465.343.34
XXXXXXXXX
21010131013182530
222222222
XXXXXXXXX
201818161816141210
2.522.763.533.854.394.676.167.488.96
4.635.116.787.428.499.05
11.0112.8715.04
SPT-1
SPT-2
SPT-3
6.36.36.36.3
10.010.010.010.010.0
2641416516264165
104
1.031.631.632.581.602.604.106.50
10.40
3646465848597899
126
3030454560608095
110
12162433354677
119180
10.36.506.504.106.614.072.581.631.02
XXXXXXXXX
21010131013182530
222222222
XXXXXXXXX
201818161816141210
99109139152173184243295353
182201267292334356434507592
SPT-1
SPT-2
SPT-3
STRANDSSIZEAWG STRAND
DIAMETER(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
EXTERNALDIMENSIONS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C 1
(ohm/km)
AMPACITY 2
(A)DIAMETER
(mm)
COPPER CONDUCTOR
STRANDSSIZEAWG STRAND
DIAMETER(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
EXTERNALDIMENSIONS
(mils)
APPROX.TOTAL
WEIGHT(lb/kft)
DCRESISTANCE
AT 20°C 1
(ohm/kft)
AMPACITY 2
(A)DIAMETER
(mils)
COPPER CONDUCTOR
TYPE
TYPE
27
Description
Soft copper flexible conductor PVC insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 60° C)
Characteristics
Operation Temperature60° C.Operating Voltage600 V.
Applications
Internal equipment wiring, boards, in ducts or raceways.Also used in low voltage automotive wiring.
Specifications
CENTELSA TFF and TWK Cables are manufactured under the followingstandards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire, for TFFUL 83, NTC-1332 Thermoplastic insulated Wires and Cables, for TWK
ColorsBlack, white, red, green, yellow, blue.
Cables Type TFF and TWKThermoplastic Insulation, Flexible Fixture WireThermoplastic Insulation, Suitable for Wet Locations, Class K Stranding
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
28
Cables Type TFF and TWK 600V, 60°C (International System Units)Thermoplastic Insulation, Flexible Fixture WireThermoplastic Insulation, Suitable for Wet Locations, Class K Stranding
Standard: UL 62, NTC 2356. Flexible and Fixture Wire, for TFFUL 83, NTC-1332 Thermoplastic insulated Wires and Cables, for TWK
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Cables Type TFF and TWK 600V, 60°CThermoplastic Insulation, Flexible Fixture WireThermoplastic Insulation, Suitable for Wet Locations, Class K Stranding
Standard: UL 62, NTC 2356. Flexible and Fixture Wire, for TFFUL 83, NTC-1332 Thermoplastic insulated Wires and Cables, for TWK
Notes: 1. Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
0.2540.2540.2540.2540.2540.2540.254
16264165
104168266
0.811.322.083.295.278.51
13.48
1.231.511.982.523.213.664.12
0.760.760.760.760.761.141.52
1520294263
104164
21.713.38.465.343.342.071.30
10131825304055
1816141210
86
2.833.113.584.124.816.047.28
TFF
TWK
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C 1
(ohm/km)
AMPACITY 2
(A)CONDUCTOR
DIAMETER(mm)
TYPE
10.010.010.010.010.010.010.0
16264165
104168266
1.602.604.106.50
10.4016.8026.60
48597899
126144162
30303030304560
101420284270
110
6.614.072.581.631.02
0.6300.398
10131825304055
1816141210
86
111122141162189238287
TFF
TWK
29
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
APPROX.TOTAL
WEIGHT(lb/kft)
DCRESISTANCE
AT 20°C 1
(ohm/kft)
AMPACITY 2
(A)CONDUCTOR
DIAMETER(mils)
TYPE
30
Description
Soft copper conductor, PVC insulated and with a Nylon covering
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationPolyvinyl Chloride (PVC 90° C), flame retardant
JacketAbrasion resistant Nylon
Characteristics
Operating Temperature90°C.
Operating Voltage600 V.
Applications
TFFN cables and wires are used generally in internal equipment and boardwiring. Installation: in ducts tubing and boards.
Special for locations with abrasive environment, oil, grease, gasoline andother chemical agents contaminated ambient. Its reduced diameter permitsan optimum utilization of ducts or sites where is installed.
Standards
CENTELSA TFFN wires and cables are manufactured under the followingstandards:
UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsUL 62, NTC-2356 Flexible Cord and Fixture Wire
Cables Type TFFNThermoplastic Insulation, Flexible Fixture Wire, Nylon Jacket
31
ColorsBlack, white, red, yellow, blue.
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein are availableupon request.
32
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Cable Type TFFN 600V (International System Units)Thermoplastic Insulation, Fixture Wire, Nylon Jacket (90° C)
Standard: UL 62, NTC-2356. Flexible Cord and Fixture Wire.
0.380.38
0.2540.254
1626
0.811.32
1.231.51
0.100.10
2.062.36
1117
21.413.4
2.292.59
68
1816
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
JACKETTHICKNESS
(mm)
DIAMETEROVER
JACKET(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
AMPACITY 2
(A)CONDUCTOR
DIAMETER(mm)
DIAMETEROVER
INSULATION(mm)
Cable Type TFFN 600V, 90°CThermoplastic Insulation, Fixture Wire, Nylon Jacket
Standard: UL 62, NTC-2356. Flexible Cord and Fixture Wire.
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacities based on 60°C conductor temperature, and Section 400 of NEC (NTC 2050) and 30°C ambient temperature.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
1515
10.010.0
1626
1.602.60
4859
44
8193
811
6.514.10
90102
68
1816
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
JACKETTHICKNESS
(mils)
DIAMETEROVER
JACKET(mm)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
AMPACITY 2
(A)CONDUCTOR
DIAMETER(mils)
DIAMETEROVER
INSULATION(mils)
33
Description
Soft copper flexible conductor PVC insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 105° C)
Characteristics
Operating Temperature105° C.
Operating Voltage600 V.
Applications
Lighting connections and high temperature applications.
Specifications
CENTELSA LIGHTING Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 83, NTC-1332 Thermoplastic insulated Wires and CablesUL 62, NTC-2356 Flexible Cord and Fixture Wire (Sizes 20 to 16 AWG)CENTELSA Specifications for LIGHTING Cables
ColorsBlack, white, red, yellow, blue.
Lighting Cables
34
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
35
Lighting Cables 105°C (International System Units)
Standard: UL 62, NTC 2356. Flexible and Fixture WireUL 83, NTC-1332 Thermoplastic insulated Wires and CablesCENTELSA Specifications for LIGHTING Cables
Lighting Cables 105°C
Standard: UL 62, NTC 2356. Flexible and Fixture WireUL 83, NTC-1332 Thermoplastic insulated Wires and CablesCENTELSA Specifications for LIGHTING Cables
0.760.760.760.760.760.761.141.52
0.2540.2540.2540.2540.2540.2540.2540.254
1016264165
104168266
0.510.811.322.083.295.278.51
13.48
0.971.231.511.982.523.213.664.12
2.232.492.773.243.784.475.526.58
34.721.713.38.465.343.342.071.30
9131826395996
152
201816141210
86
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
3030303030304560
10.010.010.010.010.010.010.010.0
1016264165
104168266
1.001.602.604.106.50
10.4016.8026.60
3848597899
126144162
8898
109128149176217259
10.66.64.1
2.581.631.020.630.40
68
1218264065
102
201816141210
86
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
36
Description
Soft copper flexible conductor XLPE insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame retardant Black Cross Linked Polyethylene (XLPE 125°C)
Characteristics
Operating Temperature125° C.
Applications
Used generally in internal equipment and board wiring. Installation in ductsor raceways. High temperature applications. Also used in automotive lowvoltage wiring. Insulation resistant to abrasion, gasoline, oil, solvents andchemical agents.
Specifications
CENTELSA XGW Cables are manufactured under the followingstandards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsCENTELSA Specifications for XGW Cables
Cables Type XGWCross (X) Linked Polyethylene Insulated 125°C, General Purpose Wire
37
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein are availableupon request.
Cables Type XGW 600V, 125°C (International System Units)Cross (X) Linked Polyethylene Insulated 125°C, General Purpose Wire
Standard: CENTELSA Specifications for XGW Cables
Cables Type XGW 600V, 125°CCross (X) Linked Polyethylene Insulated 125°C, General Purpose Wire
Standard: CENTELSA Specifications for XGW Cables
0.740.760.810.890.941.041.09
0.2540.2540.2540.2540.2540.2540.254
1016264165
104168
0.510.811.322.083.295.278.51
0.971.231.511.982.523.213.66
2.192.492.853.444.064.915.42
34.721.713.38.465.343.342.07
9131828416495
201816141210
8
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
29303235374143
10.010.010.010.010.010.010.0
1016264165
104168
1.001.602.604.106.50
10.4016.80
3848597899
126144
8495
110133157191211
10.66.614.072.581.631.02
0.630
68
1219284364
201816141210
8
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
38
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
39
Description
Soft tinned copper flexible conductor Thermoset Elastomer insulated.
Construction
ConductorFlexible tinned soft copper conductor, Class K stranded
InsulationBlack Thermoset Elastomer Flame retardant (XLPE 150°C)
Characteristics
Operating Temperature150° C.
Applications
Used generally in internal equipment and board wiring. Installation in ductsor raceways, transit zones, high temperature applications. Also used inautomotive low voltage wiring.Flexible insulation, low smoke emissions, non halogenated, lead free andexcellent thermal stability.
Specifications
CENTELSA HTS-C Cables are manufactured under the followingstandards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsCENTELSA Specifications for HTS-C Cables
Cables Type HTS-CHeavy Duty Thermoset Elastomer (Synthetic Rubber) Insulated 150°C, C: Common use
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
40
41
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Cables Type HTS-C 600V, 150°CHeavy Duty Thermoset Elastomer (Synthetic Rubber) Insulated 150°C, C: Common use
Standard: CENTELSA Specifications for HTS-C Cables
0.730.790.820.900.901.101.191.271.291.291.291.291.541.54
0.2540.2540.2540.2540.2540.2540.2540.2540.2540.2540.2540.2540.2540.254
16264165
104168266420665836
1064132316662107
0.811.322.083.295.278.51
13.4821.2833.7042.3653.9167.0484.42
106.76
1.231.511.982.523.213.664.126.728.589.77
11.1012.4714.1015.97
2.773.173.704.425.115.946.609.36
11.2612.4513.7815.1517.3019.17
22.613.9
8.85.63.52.11.40.90.50.40.30.30.20.2
1420294465
101151239365451564691878
1094
1816141210
86421
1/02/03/04/0
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
2931323636434750515151516161
10.010.010.010.010.010.010.010.010.010.010.010.010.010.0
16264165
104168266420665836
1064132316662107
1.602.604.106.50
10.4016.8026.6042.0066.5083.60
106.40132.30166.60210.70
48597899
126144162265338385437491555629
109125146174201234260369443490543596681755
6.94.232.681.691.060.650.410.260.160.130.100.080.060.05
91420304468
102161245303379464590735
1816141210
86421
1/02/03/04/0
Cables Type HTS-C 600V, 150°C (International System Unit)Heavy Duty Thermoset Elastomer (Synthetic Rubber) Insulated 150°C, C: Common use
Standard: CENTELSA Specifications for HTS-C Cables
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
42
Description
Soft copper flexible conductor PVC insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 75° C)
Characteristics
Operating Temperature75° C.
Operating Voltage50 V.
Applications
Low voltage automotive wiring. Insulation resistant to abrasion gasolineand oil.
Specifications
CENTELSA GPT Cables are manufactured under the followingstandards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsSAE J1128 NTC-1116 Primary Low Voltage Cables
ColorsBlack, white, red, yellow, blue, brown, orange grey and violet.
Automotive CablesType GPTGeneral Purpose Thermoplastic Insulated
43
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein are availableupon request.
44
Automotive Cables Type GPT 50V, 75°C(International System Units)General Purpose Thermoplastic Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Automotive Cables Type GPT 50V, 75°CGeneral Purpose Thermoplastic Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
0.580.580.580.580.580.660.790.94
0.2540.2540.2540.2540.2540.2540.2540.254
71016264165
104168
0.350.510.811.322.083.295.278.51
0.760.971.231.511.982.523.213.66
1.761.972.232.512.983.624.515.20
49.634.721.713.38.465.343.342.07
68
111624385993
22201816141210
8
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
2323232323263137
10.010.010.010.010.010.010.010.0
71016264165
104168
0.701.001.602.604.106.50
10.4016.80
303848597899
126144
69788899
117143178205
15.110.66.614.072.581.631.02
0.630
458
1116254062
22201816141210
8
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
45
Description
Soft copper flexible conductor PVC insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 75° C)
Characteristics
Operating Temperature75° C.
Operating Voltage50 V.
Applications
Low voltage automotive wiring where the reduced diameter offers an optimumutilization of site in which is installed. Insulation resistant to abrasion gasolineand oil.
Specifications
CENTELSA TWP Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsSAE J1128 NTC-1116 Primary Low Voltage Cables
ColorsBlack, white, red, yellow, blue, brown, orange grey and violet.
Automotive CablesType TWPThin Wall, Thermo Plastic Insulated
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
46
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Automotive Cable Type TWP 50V, 75°CThin Wall, ThermoPlastic Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
0.400.400.400.400.400.450.500.55
0.2540.2540.2540.2540.2540.2540.2540.254
71016264165
104168
0.350.510.811.322.083.295.278.51
0.760.971.231.511.982.523.213.66
1.441.651.912.192.663.324.074.58
49.634.721.713.38.465.343.342.07
57
101522355586
22201816141210
8
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
1616161616182022
10.010.010.010.010.010.010.010.0
71016264165
104168
0.701.001.602.604.106.50
10.4016.80
303848597899
126144
55637384
103127157178
15.110.66.614.072.581.631.02
0.630
347
1015243758
22201816141210
8
Automotive Cable Type TWP 50V, 75°C(Internacional System Units)Thin Wall, ThermoPlastic Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
47
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
48
Description
Soft copper flexible conductor PVC insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Polyvinyl chloride (PVC 75° C)
Characteristics
Operating Temperature75° C.
Operating Voltage50 V.
Applications
SGT cables are used to connect the system of engine Start-up. Insulationis resistant to abrasion, gasoline, oil, solvents and chemical agents.
Specifications
CENTELSA SGT Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsSAE J1127 NTC-1955 Battery Cables
Starter or Ground, General Purpose Thermoplastic Insulated
Automotive Cables Type SGT.Battery Cable
49
PackagingWood reels or spools upon request.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Automotive Cables Type SGT 50V, 75°CStarter or Ground, General Purpose Thermoplastic Insulated
Standard: SAE J1127 NTC-1955. Battery Cables
1.521.651.651.651.651.651.981.98
0.2540.2540.2540.2540.2540.2540.2540.254
266420665836
1064132316662107
13.4821.2833.7042.3653.9167.0484.42
106.76
4.126.728.589.77
11.1012.4714.1015.97
6.589.40
11.2612.4513.7815.1517.3019.17
1.300.8260.5220.4150.3260.2620.2080.165
152243368454568697886
1105
6421
1/02/03/04/0
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
6065656565657878
10.010.010.010.010.010.010.010.0
266420665836
1064132316662107
26.6042.0066.5083.60
106.40132.30166.60210.70
162265338385437491555629
259370443490543596681755
0.3980.2520.1590.127
0.09940.08000.06350.0502
102163247305382469595742
6421
1/02/03/04/0
Automotive Cables Type SGT 50V, 75°C (International System Unit)Starter or Ground, General Purpose Thermoplastic Insulated
Standard: SAE J1127 NTC-1955. Battery Cables
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
50
Description
Soft copper flexible conductor XLPE insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame retardant Cross Linked Polyethylene (XLPE 125°C)
Characteristics
Operating Temperature125° C.
Operating Voltage50 V.
Applications
Low voltage automotive, special for vane motor. Applications whereheavy duty requires more than GPT cables. Insulation resistant toabrasion gasoline and oil.
Specifications
CENTELSA SXL Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables andFlexible CordsSAE J1128 NTC-1116 Primary Low Voltage Cables
ColorsBlack, red, orange
Automotive CablesType SXLSpecial Purpose, Cross (X) Linked Polyethylene Insulated
51
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified herein areavailable upon request.
52
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Automotive Cables Type SXL 50V, 75°CSpecial Purpose, Cross (X) Linked Polyethylene Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
0.740.760.810.890.941.041.09
0.2540.2540.2540.2540.2540.2540.254
1016264165
104168
0.510.811.322.083.295.278.51
0.971.231.511.982.523.213.66
2.192.492.853.444.064.915.42
34.721.713.38.465.343.342.07
9131828416495
201816141210
8
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
29303235374143
10.010.010.010.010.010.010.0
1016264165
104168
1.001.602.604.106.50
10.4016.80
3848597899
126144
8495
110133157191211
10.66.614.072.581.631.02
0.630
68
1219284364
201816141210
8
Automotive Cables Type SXL 50V, 75°C(International System Unit)Special Purpose, Cross (X) Linked Polyethylene Insulated
Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
53
Description
Soft copper flexible conductor Silicon Rubber insulated.
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationSilicon Rubber natural color (Beige)
Characteristics
Operation Temperature200° C.Operating Voltage600 V.
Applications
High temperature applications like motors wiring, internal wiring of luminaries,ballast, dryers, ovens, freezers, coolersExcellent insulation performance at high temperatures
Specifications
CENTELSA SF Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire
Silicon Cables Type SFSilicon Insulated Flexible
54
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
Silicon Cable Type SF 600V, 200°CSilicon Insulated Flexible
Standard: UL 62, NTC-2356. Flexible and Fixture Wire
3030303030
10.010.010.010.010.0
16264165
104
1.602.604.106.50
10.40
48597899
126
111122141162189
6.614.072.581.631.02
913182740
1816141210
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
Silicon Cable Type SF 600V, 200°C(International System Unit)Silicon Insulated Flexible
Standard: UL 62, NTC-2356. Flexible and Fixture Wire
0.760.760.760.760.76
0.2540.2540.2540.2540.254
16264165
104
0.811.322.083.295.27
1.231.511.982.523.21
2.833.113.584.124.81
21.713.38.465.343.34
1319274060
1816141210
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
55
Description
Soft copper flexible conductor with Elastomer Thermoplastic insulation
Construction
ConductorFlexible soft copper conductor, Class K stranded
InsulationFlame Retardant Black Elastomer Thermoplastic i(TPR 105°C)
Characteristics
Operation Temperature105° C.Operating Voltage600 V.
Applications
Extra hard service Cable, flexible and resistant to heavy-duty, for electricwelding equipments.Insulation: Rough handling, abrasion and spark welding resistant.
Specifications
CENTELSA SF Cables are manufactured under the following standards:UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and FlexibleCordsUL 62, NTC-2356 Flexible Cord and Fixture Wire
Welding Cable
Packaging100 m spools covered with plastic thermo pack, in corrugated carton boxes.
Note: Other configurations, sizes, colors and length not specified hereinare available upon request.
56
Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity.2. Ampacity based on 5 minutes working cycles and 80% Load Factor.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
WELDING Cable 600V, 105oC
Standard: BS 638. Arc welding power coerces equipment and accessories.CENTELSA Specifications for HTS-C Cables
0.2540.2540.2540.2540.2540.2540.2540.2540.2540.2540.254
266420665836
1064132316662107249929893458
13.4821.2833.7042.3653.9167.0484.42
106.76126.63151.45175.22
4.126.728.589.77
11.1012.4714.1015.9717.4019.0220.61
2.002.002.002.202.402.402.602.802.803.003.20
168258389487616756947
1189139016581933
1.300.8260.5220.4150.3260.2620.2080.1650.1390.1160.100
125170232270318369431505566639705
6421
1/02/03/04/0
250300350
8.2810.8812.7414.3116.0417.4119.4621.7323.1625.2027.21
Welding Cable 600V, 105oC (International System Units)
Standard: BS 638. Arc welding power coerces equipment and accessories.CENTELSA Specifications for HTS-C Cables
Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity.2. Ampacity based on 5 minutes working cycles and 80% Load Factor.3. Values herein indicated are approximated and are subject to normal manufacturing tolerances.
10.010.010.010.010.010.010.010.010.010.010.0
266420665836
1064132316662107249929893458
26.6042.0066.5083.60
106.40132.30166.60210.70249.90298.90345.81
162265338385437491555629685749811
797979879494
102110110118126
113174261327414508636799934
11141299
0.3980.2520.1590.127
0.09940.08000.06350.05020.04230.03540.0306
125170232270318369431505566639705
6421
1/02/03/04/0
250300350
326428502563631685766856912992
1071
57
STRANDSSIZEAWG
STRANDDIAMETER
(mm)
SECTION(mm2)
INSULATIONTHICKNESS
(mm)
DIAMETEROVER
INSULATION(mm)
DCRESISTANCE
AT 20°C 1(ohm/km)
APPROX.TOTAL
WEIGHT(kg/km)
CONDUCTORDIAMETER
(mm)
STRANDSSIZEAWG
STRANDDIAMETER
(mils)
SECTION(kcmil)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
DCRESISTANCE
AT 20°C 1(ohm/kft)
APPROX.TOTAL
WEIGHT(lb/kft)
CONDUCTORDIAMETER
(mils)
AMPACITY 2(A)
AMPACITY 2(A)