66
NetApp Verified Architecture FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 NVA Deployment Savita Kumari, NetApp January 2019 | NVA-1123-DEPLOY | Version 1.0 Reviewed by
Transcript
Page 1: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

NetApp Verified Architecture

FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 NVA Deployment

Savita Kumari, NetApp

January 2019 | NVA-1123-DEPLOY | Version 1.0

Reviewed by

Page 2: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

2 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

TABLE OF CONTENTS

1 Program Summary................................................................................................................................ 4

2 Solution Overview ................................................................................................................................ 4

2.1 FlexPod Converged Infrastructure Program .................................................................................................... 4

2.2 NetApp Verified Architecture Program ............................................................................................................ 5

2.3 Solution Technology ....................................................................................................................................... 6

2.4 Use Case Summary ........................................................................................................................................ 6

3 Technology Requirements .................................................................................................................. 7

3.1 Hardware Requirements ................................................................................................................................. 7

3.2 Software Requirements .................................................................................................................................. 8

4 FlexPod Express Cabling Information ................................................................................................ 9

5 Deployment Procedures .................................................................................................................... 11

5.1 Cisco Nexus 3172P Deployment Procedure ................................................................................................. 12

5.2 NetApp Storage Deployment Procedure (Part 1) .......................................................................................... 18

5.3 Cisco UCS C-Series Rack Server Deployment Procedure ........................................................................... 34

5.4 NetApp AFF Storage Deployment Procedure (Part 2) .................................................................................. 44

5.5 VMware vSphere 6.7 Deployment Procedure ............................................................................................... 45

5.6 Install VMware vCenter Server 6.7 ............................................................................................................... 58

5.7 Configure VMware vCenter Server 6.7 and vSphere Clustering ................................................................... 62

6 Conclusion .......................................................................................................................................... 64

Acknowledgments .................................................................................................................................... 65

Where to Find Additional Information .................................................................................................... 65

LIST OF TABLES

Table 1) Hardware requirements for the base configuration........................................................................................... 7

Table 2) Hardware for scaling the solution by adding two hypervisor nodes. ................................................................. 7

Table 3) Software requirements for the base FlexPod Express implementation. ........................................................... 8

Table 4) Software requirements for a VMware vSphere implementation. ...................................................................... 8

Table 5) Cabling information for Cisco Nexus switch 3172P A. ...................................................................................... 9

Table 6) Cabling information for Cisco Nexus switch 3172P B. .................................................................................... 10

Table 7) Cabling information for NetApp AFF A220 storage controller A. .................................................................... 10

Table 8) Cabling information for NetApp AFF A220 storage controller B. .................................................................... 10

Table 9) Required VLANs. ............................................................................................................................................ 11

Table 10) VMware virtual machines created. ............................................................................................................... 11

Table 11) Information required for NFS configuration. ................................................................................................. 30

Page 3: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

3 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Table 12) Information required for iSCSI configuration. ............................................................................................... 32

Table 13) Information required for NFS configuration. ................................................................................................. 33

Table 14) Information required for SVM administrator addition. ................................................................................... 33

Table 15) Information required for CIMC configuration. ............................................................................................... 34

Table 16) Information required for iSCSI boot configuration. ........................................................................................ 37

Table 17) Information required for configuring ESXi hosts. .......................................................................................... 48

LIST OF FIGURES

Figure 1) FlexPod portfolio. ............................................................................................................................................ 5

Figure 2) FlexPod Express with VMware vSphere 10GbE architecture. ........................................................................ 6

Figure 3) Reference validation cabling. .......................................................................................................................... 9

Page 4: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

4 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Program Summary

Industry trends indicate a vast data center transformation toward shared infrastructure and cloud

computing. In addition, organizations seek a simple and effective solution for remote and branch offices,

leveraging the technology with which they are familiar in their data center.

FlexPod® Express is a predesigned, best practice data center architecture that is built on the Cisco

Unified Computing System (Cisco UCS), the Cisco Nexus family of switches, and NetApp® storage

technologies. The components in a FlexPod Express system are like their FlexPod Datacenter

counterparts, enabling management synergies across the complete IT infrastructure environment on a

smaller scale. FlexPod Datacenter and FlexPod Express are optimal platforms for virtualization and for

bare-metal operating systems and enterprise workloads.

FlexPod Datacenter and FlexPod Express deliver a baseline configuration and have the flexibility to be

sized and optimized to accommodate many different use cases and requirements. Existing FlexPod

Datacenter customers can manage their FlexPod Express system with the tools to which they are

accustomed. New FlexPod Express customers can easily adapt to managing FlexPod Datacenter as their

environment grows.

FlexPod Express is an optimal infrastructure foundation for remote and branch offices and for small to

midsize businesses. It is also an optimal solution for customers who want to provide infrastructure for a

dedicated workload.

FlexPod Express provides an easy-to-manage infrastructure that is suitable for almost any workload.

Solution Overview

This FlexPod Express solution is part of the FlexPod Converged Infrastructure Program.

2.1 FlexPod Converged Infrastructure Program

FlexPod reference architectures are delivered as Cisco Validated Designs (CVDs) or NetApp Verified

Architectures (NVAs). Deviations based on customer requirements from a given CVD or NVA are

permitted if these variations do not create an unsupported configuration.

As depicted in Figure 1, the FlexPod program includes three solutions: FlexPod Express, FlexPod

Datacenter, and FlexPod Select:

• FlexPod Express offers customers an entry-level solution with technologies from Cisco and NetApp.

• FlexPod Datacenter delivers an optimal multipurpose foundation for various workloads and applications.

• FlexPod Select incorporates the best aspects of FlexPod Datacenter and tailors the infrastructure to a given application.

Page 5: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

5 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Figure 1) FlexPod portfolio.

2.2 NetApp Verified Architecture Program

The NetApp Verified Architecture program offers customers a verified architecture for NetApp solutions. A

NetApp Verified Architecture provides a NetApp solution architecture with the following qualities:

• Is thoroughly tested

• Is prescriptive in nature

• Minimizes deployment risks

• Accelerates time to market

This guide details the design of FlexPod Express with VMware vSphere. In addition, this design uses the

all-new AFF A220 system, which runs NetApp ONTAP® 9.4; the Cisco Nexus 3172P; and Cisco UCS C-

Series C220 M5 servers as hypervisor nodes.

Page 6: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

6 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

2.3 Solution Technology

This solution leverages the latest technologies from NetApp, Cisco, and VMware. This solution features

the new NetApp AFF A220 running ONTAP 9.4, dual Cisco Nexus 3172P switches, and Cisco UCS C220

M5 rack servers that run VMware vSphere 6.7. This validated solution uses 10GbE technology. Guidance

is also provided on how to scale compute capacity by adding two hypervisor nodes at a time so that the

FlexPod Express architecture can adapt to an organization’s evolving business needs.

Figure 2) FlexPod Express with VMware vSphere 10GbE architecture.

Note: This validation uses 10GbE connectivity and Cisco UCS VIC 1387, which is 40GbE. To achieve 10GbE connectivity, the CVR-QSFP-SFP10G adapter is used.

2.4 Use Case Summary

The FlexPod Express solution can be applied to several use cases, including the following:

• Remote offices or branch offices

• Small and midsize businesses

• Environments that require a dedicated and cost-effective solution

FlexPod Express is best suited for virtualized and mixed workloads.

Page 7: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

7 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: Although this solution was validated with vSphere 6.7, it supports any vSphere version qualified with the other components by the NetApp Interoperability Matrix Tool. NetApp recommends deploying vSphere 6.7U1 for its fixes and enhanced features.

The following are some of the features of vSphere 6.7 U1:

• Fully featured HTML5 web-based vSphere Client

• vMotion for NVIDIA GRID vGPU VMs. Support for Intel FPGA.

• vCenter Server Converge Tool to move from external PSC to internal PCS.

• Enhancements for vSAN (HCI updates).

• Enhanced content library.

For details about vSphere 6.7 U1, see https://blogs.vmware.com/vsphere/2018/10/whats-new-in-vcenter-server-6-7-update-1.html.

Technology Requirements

A FlexPod Express system requires a combination of hardware and software components. FlexPod

Express also describes the hardware components that are required to add hypervisor nodes to the

system in units of two.

3.1 Hardware Requirements

Regardless of the hypervisor chosen, all FlexPod Express configurations use the same hardware.

Therefore, even if business requirements change, either hypervisor can run on the same FlexPod

Express hardware.

Table 1 lists the hardware components that are required for all FlexPod Express configurations.

Table 1) Hardware requirements for the base configuration.

Hardware Quantity

AFF A220 HA Pair 1

Cisco C220 M5 server 2

Cisco Nexus 3172P switch 2

Cisco UCS virtual interface card (VIC) 1387 for the C220 M5 server

2

CVR-QSFP-SFP10G adapter 4

Table 2 lists the hardware that is required in addition to the base configuration for implementing 10GbE.

Table 2) Hardware for scaling the solution by adding two hypervisor nodes.

Hardware Quantity

Cisco UCS C220 M5 server 2

Cisco VIC 1387 2

CVR-QSFP-SFP10G adapter 4

Page 8: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

8 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3.2 Software Requirements

Table 3 lists the software components that are required to implement the architectures of the FlexPod

Express solutions.

Table 3) Software requirements for the base FlexPod Express implementation.

Software Version Details

Cisco Integrated Management Controller (CIMC)

3.1(3g) For Cisco UCS C220 M5 rack servers

Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards

Cisco NX-OS nxos.7.0.3.I7.5.bin For Cisco Nexus 3172P switches

NetApp ONTAP 9.4 For AFF A220 controllers

Table 4 lists the software that is required for all VMware vSphere implementations on FlexPod Express.

Table 4) Software requirements for a VMware vSphere implementation.

Software Version

VMware vCenter server appliance 6.7

VMware vSphere ESXi hypervisor 6.7

NetApp VAAI Plug-In for ESXi 1.1.2

Page 9: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

9 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

FlexPod Express Cabling Information

The reference of validation documented is cabled as shown in Figure 3 and Tables 5 through 8.

Figure 3) Reference validation cabling.

Table 5) Cabling information for Cisco Nexus switch 3172P A.

Local Device Local Port Remote Device Remote Port

Cisco Nexus switch 3172P A

Eth1/1 NetApp AFF A220 storage controller A e0c

Eth1/2 NetApp AFF A220 storage controller B e0c

Eth1/3 Cisco UCS C220 C-Series standalone server A MLOM1 with CVR-QSFP-SFP10G adapter

Eth1/4 Cisco UCS C220 C-Series standalone server B MLOM1 with CVR-QSFP-SFP10G adapter

Eth1/25 Cisco Nexus switch 3172P B Eth1/25

Eth1/26 Cisco Nexus switch 3172P B Eth1/26

Eth1/33 NetApp AFF A220 storage controller A e0M

Page 10: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

10 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Local Device Local Port Remote Device Remote Port

Eth1/34 Cisco UCS C220 C-Series standalone server A CIMC

Table 6) Cabling information for Cisco Nexus switch 3172P B.

Local Device Local Port Remote Device Remote Port

Cisco Nexus switch 3172P B

Eth1/1 NetApp AFF A220 storage controller A e0d

Eth1/2 NetApp AFF A220 storage controller B e0d

Eth1/3 Cisco UCS C220 C-Series standalone server A MLOM2 with CVR-QSFP-SFP10G adapter

Eth1/4 Cisco UCS C220 C-Series standalone server B MLOM2 with CVR-QSFP-SFP10G adapter

Eth1/25 Cisco Nexus switch 3172P A Eth1/25

Eth1/26 Cisco Nexus switch 3172P A Eth1/26

Eth1/33 NetApp AFF A220 storage controller B e0M

Eth1/34 Cisco UCS C220 C-Series standalone server B CIMC

Table 7) Cabling information for NetApp AFF A220 storage controller A.

Local Device Local Port Remote Device Remote Port

NetApp AFF A220 storage controller A

e0a NetApp AFF A220 storage controller B e0a

e0b NetApp AFF A220 storage controller B e0b

e0c Cisco Nexus switch 3172P A Eth1/1

e0d Cisco Nexus switch 3172P B Eth1/1

e0M Cisco Nexus switch 3172P A Eth1/33

Table 8) Cabling information for NetApp AFF A220 storage controller B.

Local Device Local Port Remote Device Remote Port

NetApp AFF A220 storage controller B

e0a NetApp AFF A220 storage controller A e0a

e0b NetApp AFF A220 storage controller A e0b

e0c Cisco Nexus switch 3172P A Eth1/2

e0d Cisco Nexus switch 3172P B Eth1/2

e0M Cisco Nexus switch 3172P B Eth1/33

Page 11: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

11 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Deployment Procedures

This document provides details for configuring a fully redundant, highly available FlexPod Express

system. To reflect this redundancy, the components being configured in each step are referred to as

either component A or component B. For example, controller A and controller B identify the two NetApp

storage controllers that are provisioned in this document. Switch A and switch B identify a pair of Cisco

Nexus switches.

In addition, this document describes steps for provisioning multiple Cisco UCS hosts, which are identified

sequentially as server A, server B, and so on.

To indicate that you should include information pertinent to your environment in a step, <<text>>

appears as part of the command structure. See the following example for the vlan create command:

Controller01>vlan create vif0 <<mgmt_vlan_id>>

This document enables you to fully configure the FlexPod Express environment. In this process, various

steps require you to insert customer-specific naming conventions, IP addresses, and virtual local area

network (VLAN) schemes. Table 9 describes the VLANs required for deployment, as outlined in this

guide. This table can be completed based on the specific site variables and used to implement the

document configuration steps.

Note: If you use separate in-band and out-of-band management VLANs, you must create a layer 3 route between them. For this validation, a common management VLAN was used.

Table 9) Required VLANs.

AN Name VLAN Purpose ID Used in Validating This Document

Management VLAN VLAN for management interfaces 3437

Native VLAN VLAN to which untagged frames are assigned

2

NFS VLAN VLAN for NFS traffic 3438

VMware vMotion VLAN VLAN designated for the movement of virtual machines from one physical host to another

3441

Virtual machine traffic VLAN VLAN for virtual machine application traffic 3442

iSCSI-A-VLAN VLAN for iSCSI traffic on fabric A 3439

iSCSI-B-VLAN VLAN for iSCSI traffic on fabric B 3440

The VLAN numbers are needed throughout the configuration of FlexPod Express. The VLANs are

referred to as <<var_xxxx_vlan>>, where xxxx is the purpose of the VLAN (such as iSCSI-A).

Table 10 lists the VMware virtual machines created.

Table 10) VMware virtual machines created.

Virtual Machine Description Host Name

VMware vCenter Server

Page 12: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

12 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5.1 Cisco Nexus 3172P Deployment Procedure

The following section details the Cisco Nexus 3172P switch configuration used in a FlexPod Express

environment.

Initial Setup of Cisco Nexus 3172P Switch The following procedures describe how to configure the Cisco Nexus switches for use in a base FlexPod Express environment.

Note: This procedure assumes that you are using a Cisco Nexus 3172P running NX-OS software release 7.0(3)I7(5).

1. Upon initial boot and connection to the console port of the switch, the Cisco NX-OS setup automatically starts. This initial configuration addresses basic settings, such as the switch name, the mgmt0 interface configuration, and Secure Shell (SSH) setup.

2. The FlexPod Express management network can be configured in multiple ways. The mgmt0 interfaces on the 3172P switches can be connected to an existing management network, or the mgmt0 interfaces of the 3172P switches can be connected in a back-to-back configuration. However, this link cannot be used for external management access such as SSH traffic.

Note: In this deployment guide, the FlexPod Express Cisco Nexus 3172P switches are connected to an existing management network.

3. To configure the Cisco Nexus 3172P switches, power on the switch and follow the on-screen prompts, as illustrated here for the initial setup of both the switches, substituting the appropriate values for the switch-specific information.

This setup utility will guide you through the basic configuration of

the system. Setup configures only enough connectivity for management

of the system.

*Note: setup is mainly used for configuring the system initially,

when no configuration is present. So setup always assumes system

defaults and not the current system configuration values.

Press Enter at anytime to skip a dialog. Use ctrl-c at anytime

to skip the remaining dialogs.

Would you like to enter the basic configuration dialog (yes/no): y

Do you want to enforce secure password standard (yes/no) [y]: y

Create another login account (yes/no) [n]: n

Configure read-only SNMP community string (yes/no) [n]: n

Configure read-write SNMP community string (yes/no) [n]: n

Enter the switch name : 3172P-B

Continue with Out-of-band (mgmt0) management configuration? (yes/no) [y]: y

Mgmt0 IPv4 address : <<var_switch_mgmt_ip>>

Mgmt0 IPv4 netmask : <<var_switch_mgmt_netmask>>

Configure the default gateway? (yes/no) [y]: y

IPv4 address of the default gateway : <<var_switch_mgmt_gateway>>

Configure advanced IP options? (yes/no) [n]: n

Enable the telnet service? (yes/no) [n]: n

Enable the ssh service? (yes/no) [y]: y

Page 13: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

13 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Type of ssh key you would like to generate (dsa/rsa) [rsa]: rsa

Number of rsa key bits <1024-2048> [1024]: <enter>

Configure the ntp server? (yes/no) [n]: y

NTP server IPv4 address : <<var_ntp_ip>>

Configure default interface layer (L3/L2) [L2]: <enter>

Configure default switchport interface state (shut/noshut) [noshut]: <enter>

Configure CoPP system profile (strict/moderate/lenient/dense) [strict]: <enter>

4. You then see a summary of your configuration, and you are asked if you would like to edit it. If your configuration is correct, enter n.

Would you like to edit the configuration? (yes/no) [n]: n

5. You are then asked if you would like to use this configuration and save it. If so, enter y.

Use this configuration and save it? (yes/no) [y]: Enter

6. Repeat this procedure for Cisco Nexus switch B.

Enable Advanced Features

Certain advanced features must be enabled in Cisco NX-OS to provide additional configuration options.

Note: The interface-vlan feature is required only if you use the back-to-back mgmt0 option described throughout this document. This feature allows you to assign an IP address to the interface VLAN (switch virtual interface), which enables in-band management communication to the switch (such as through SSH).

1. To enable the appropriate features on Cisco Nexus switch A and switch B, enter configuration mode using the command (config t) and run the following commands:

feature interface-vlan

feature lacp

feature vpc

Note: The default port channel load-balancing hash uses the source and destination IP addresses to determine the load-balancing algorithm across the interfaces in the port channel. You can achieve better distribution across the members of the port channel by providing more inputs to the hash algorithm beyond the source and destination IP addresses. For the same reason, NetApp highly recommends adding the source and destination TCP ports to the hash algorithm.

2. From configuration mode (config t), enter the following commands to set the global port channel

load-balancing configuration on Cisco Nexus switch A and switch B:

port-channel load-balance src-dst ip-l4port

Perform Global Spanning-Tree Configuration

The Cisco Nexus platform uses a new protection feature called bridge assurance. Bridge assurance helps

protect against a unidirectional link or other software failure with a device that continues to forward data

traffic when it is no longer running the spanning-tree algorithm. Ports can be placed in one of several

states, including network or edge, depending on the platform.

NetApp recommends setting bridge assurance so that all ports are considered to be network ports by

default. This setting forces the network administrator to review the configuration of each port. It also

reveals the most common configuration errors, such as unidentified edge ports or a neighbor that does

not have the bridge assurance feature enabled. In addition, it is safer to have the spanning tree block

Page 14: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

14 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

many ports rather than too few, which allows the default port state to enhance the overall stability of the

network.

Pay close attention to the spanning-tree state when adding servers, storage, and uplink switches,

especially if they do not support bridge assurance. In such cases, you might need to change the port type

to make the ports active.

The Bridge Protocol Data Unit (BPDU) guard is enabled on edge ports by default as another layer of

protection. To prevent loops in the network, this feature shuts down the port if BPDUs from another switch

are seen on this interface.

From configuration mode (config t), run the following commands to configure the default spanning-tree

options, including the default port type and BPDU guard, on Cisco Nexus switch A and switch B:

spanning-tree port type network default

spanning-tree port type edge bpduguard default

Define VLANs

Before individual ports with different VLANs are configured, the layer 2 VLANs must be defined on the

switch. It is also a good practice to name the VLANs for easy troubleshooting in the future.

From configuration mode (config t), run the following commands to define and describe the layer 2

VLANs on Cisco Nexus switch A and switch B:

vlan <<nfs_vlan_id>>

name NFS-VLAN

vlan <<iSCSI_A_vlan_id>>

name iSCSI-A-VLAN

vlan <<iSCSI_B_vlan_id>>

name iSCSI-B-VLAN

vlan <<vmotion_vlan_id>>

name vMotion-VLAN

vlan <<vmtraffic_vlan_id>>

name VM-Traffic-VLAN

vlan <<mgmt_vlan_id>>

name MGMT-VLAN

vlan <<native_vlan_id>>

name NATIVE-VLAN

exit

Configure Access and Management Port Descriptions

As is the case with assigning names to the layer 2 VLANs, setting descriptions for all the interfaces can

help with both provisioning and troubleshooting.

From configuration mode (config t) in each of the switches, enter the following port descriptions for the

FlexPod Express large configuration:

Cisco Nexus Switch A

int eth1/1

description AFF A220-A e0c

int eth1/2

description AFF A220-B e0c

int eth1/3

description UCS-Server-A: MLOM port 0

int eth1/4

description UCS-Server-B: MLOM port 0

int eth1/25

description vPC peer-link 3172P-B 1/25

int eth1/26

description vPC peer-link 3172P-B 1/26

int eth1/33

description AFF A220-A e0M

Page 15: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

15 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

int eth1/34

description UCS Server A: CIMC

Cisco Nexus Switch B

int eth1/1

description AFF A220-A e0d

int eth1/2

description AFF A220-B e0d

int eth1/3

description UCS-Server-A: MLOM port 1

int eth1/4

description UCS-Server-B: MLOM port 1

int eth1/25

description vPC peer-link 3172P-A 1/25

int eth1/26

description vPC peer-link 3172P-A 1/26

int eth1/33

description AFF A220-B e0M

int eth1/34

description UCS Server B: CIMC

Configure Server and Storage Management Interfaces

The management interfaces for both the server and the storage typically use only a single VLAN.

Therefore, configure the management interface ports as access ports. Define the management VLAN for

each switch and change the spanning-tree port type to edge.

From configuration mode (config t), enter the following commands to configure the port settings for the

management interfaces of both the servers and the storage:

Cisco Nexus Switch A

int eth1/33-34

switchport mode access

switchport access vlan <<mgmt_vlan>>

spanning-tree port type edge

speed 1000

exit

Cisco Nexus Switch B

int eth1/33-34

switchport mode access

switchport access vlan <<mgmt_vlan>>

spanning-tree port type edge

speed 1000

exit

Perform Virtual Port Channel Global Configuration A virtual port channel (vPC) enables links that are physically connected to two different Cisco Nexus switches to appear as a single port channel to a third device. The third device can be a switch, server, or any other networking device. A vPC can provide layer 2 multipathing, which allows you to create redundancy by increasing bandwidth, enabling multiple parallel paths between nodes, and load-balancing traffic where alternative paths exist.

A vPC provides the following benefits:

• Enabling a single device to use a port channel across two upstream devices

• Eliminating spanning-tree protocol blocked ports

• Providing a loop-free topology

• Using all available uplink bandwidth

Page 16: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

16 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

• Providing fast convergence if either the link or a device fails

• Providing link-level resiliency

• Helping provide high availability

The vPC feature requires some initial setup between the two Cisco Nexus switches to function properly. If

you use the back-to-back mgmt0 configuration, use the addresses defined on the interfaces and verify

that they can communicate by using the ping <<switch_A/B_mgmt0_ip_addr>>vrf management

command.

From configuration mode (config t), run the following commands to configure the vPC global

configuration for both switches:

Cisco Nexus Switch A

vpc domain 1

role priority 10

peer-keepalive destination <<switch_B_mgmt0_ip_addr>> source <<switch_A_mgmt0_ip_addr>> vrf

management

peer-gateway

auto-recovery

ip arp synchronize

int eth1/25-26

channel-group 10 mode active

int Po10

description vPC peer-link

switchport

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan <<nfs_vlan_id>>,<<vmotion_vlan_id>>, <<vmtraffic_vlan_id>>,

<<mgmt_vlan>, <<iSCSI_A_vlan_id>>, <<iSCSI_B_vlan_id>>

spanning-tree port type network

vpc peer-link

no shut

exit

copy run start

Cisco Nexus Switch B

vpc domain 1

peer-switch

role priority 20

peer-keepalive destination <<switch_A_mgmt0_ip_addr>> source <<switch_B_mgmt0_ip_addr>> vrf

management

peer-gateway

auto-recovery

ip arp synchronize

int eth1/25-26

channel-group 10 mode active

int Po10

description vPC peer-link

switchport

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan <<nfs_vlan_id>>,<<vmotion_vlan_id>>, <<vmtraffic_vlan_id>>,

<<mgmt_vlan>>, <<iSCSI_A_vlan_id>>, <<iSCSI_B_vlan_id>>

spanning-tree port type network

vpc peer-link

no shut

exit

copy run start

Page 17: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

17 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Configure Storage Port Channels

The NetApp storage controllers allow an active-active connection to the network using the Link

Aggregation Control Protocol (LACP). The use of LACP is preferred because it adds both negotiation and

logging between the switches. Because the network is set up for vPC, this approach enables you to have

active-active connections from the storage to separate physical switches. Each controller has two links to

each of the switches. However, all four links are part of the same vPC and interface group (IFGRP).

From configuration mode (config t), run the following commands on each of the switches to configure

the individual interfaces and the resulting port channel configuration for the ports connected to the

NetApp AFF controller.

1. Run the following commands on switch A and switch B to configure the port channels for storage controller A:

int eth1/1

channel-group 11 mode active

int Po11

description vPC to Controller-A

switchport

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan <<nfs_vlan_id>>,<<mgmt_vlan_id>>,<<iSCSI_A_vlan_id>>,

<<iSCSI_B_vlan_id>>

spanning-tree port type edge trunk

mtu 9216

vpc 11

no shut

2. Run the following commands on switch A and switch B to configure the port channels for storage controller B.

int eth1/2

channel-group 12 mode active

int Po12

description vPC to Controller-B

switchport

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan <<nfs_vlan_id>>,<<mgmt_vlan_id>>, <<iSCSI_A_vlan_id>>,

<<iSCSI_B_vlan_id>>

spanning-tree port type edge trunk

mtu 9216

vpc 12

no shut

exit

copy run start

Note: In this solution validation, an MTU of 9000 was used. However, based on application requirements, you can configure an appropriate value of MTU. It is important to set the same MTU value across the FlexPod solution. Incorrect MTU configurations between components will result in packets being dropped and these packets

Configure Server Connections

The Cisco UCS servers have a two-port virtual interface card, VIC1387, that is used for data traffic and

booting of the ESXi operating system using iSCSI. These interfaces are configured to fail over to one

another, providing additional redundancy beyond a single link. Spreading these links across multiple

switches enables the server to survive even a complete switch failure.

From configuration mode (config t), run the following commands to configure the port settings for the

interfaces connected to each server.

Page 18: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

18 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Cisco Nexus Switch A: Cisco UCS Server-A and Cisco UCS Server-B Configuration

int eth1/3-4

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan

<<iSCSI_A_vlan_id>>,<<nfs_vlan_id>>,<<vmotion_vlan_id>>,<<vmtraffic_vlan_id>>,<<mgmt_vlan_id>>

spanning-tree port type edge trunk

mtu9216

no shut

exit

copy run start

Cisco Nexus Switch B: Cisco UCS Server-A and Cisco UCS Server-B Configuration

int eth1/3-4

switchport mode trunk

switchport trunk native vlan <<native_vlan_id>>

switchport trunk allowed vlan

<<iSCSI_B_vlan_id>>,<<nfs_vlan_id>>,<<vmotion_vlan_id>>,<<vmtraffic_vlan_id>>,<<mgmt_vlan_id>>

spanning-tree port type edge trunk

mtu 9216

no shut

exit

copy run start

Note: In this solution validation, an MTU of 9000 was used. However, based on application requirements, you can configure an appropriate value of MTU. It is important to set the same MTU value across the FlexPod solution. Incorrect MTU configurations between components will result in packets being dropped and these packets will need to be transmitted again. This will affect the overall performance of the solution.

Note: To scale the solution by adding additional Cisco UCS servers, run the previous commands with the switch ports that the newly added servers have been plugged into on switches A and B.

Uplink into Existing Network Infrastructure Depending on the available network infrastructure, several methods and features can be used to uplink the FlexPod environment. If an existing Cisco Nexus environment is present, NetApp recommends using vPCs to uplink the Cisco Nexus 3172P switches included in the FlexPod environment into the infrastructure. The uplinks may be 10GbE uplinks for a 10GbE infrastructure solution or 1GbE for a 1GbE infrastructure solution if required. The previously described procedures can be used to create an uplink vPC to the existing environment. Make sure to run copy run start to save the configuration on each switch after the configuration is completed.

5.2 NetApp Storage Deployment Procedure (Part 1)

This section describes the NetApp AFF storage deployment procedure.

NetApp Storage Controller AFF2xx Series Installation

NetApp Hardware Universe

The NetApp Hardware Universe (HWU) application provides supported hardware and software

components for any specific ONTAP version. It provides configuration information for all the NetApp

storage appliances currently supported by ONTAP software. It also provides a table of component

compatibilities.

Confirm that the hardware and software components that you would like to use are supported with the

version of ONTAP that you plan to install:

Page 19: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

19 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

1. Access the HWU application to view the system configuration guides. Click the Controllers tab to view the compatibility between different version of the ONTAP software and the NetApp storage appliances with your desired specifications.

2. Alternatively, to compare components by storage appliance, click Compare Storage Systems.

Controller AFF2XX Series Prerequisites

To plan the physical location of the storage systems, see the NetApp Hardware Universe. Refer to the following sections:

• Electrical requirements

• Supported power cords

• Onboard ports and cables

Storage Controllers

Follow the physical installation procedures for the controllers in the AFF A220 Documentation.

NetApp ONTAP 9.4

Configuration Worksheet

Before running the setup script, complete the configuration worksheet from the product manual. The

configuration worksheet is available in the ONTAP 9.4 Software Setup Guide.

Note: This system is set up in a two-node switchless cluster configuration.

Table 12) ONTAP 9.4 installation and configuration information.

Cluster Detail Cluster Detail Value

Cluster node A IP address <<var_nodeA_mgmt_ip>>

Cluster node A netmask <<var_nodeA_mgmt_mask>>

Cluster node A gateway <<var_nodeA_mgmt_gateway>>

Cluster node A name <<var_nodeA>>

Cluster node B IP address <<var_nodeB_mgmt_ip>>

Cluster node B netmask <<var_nodeB_mgmt_mask>>

Cluster node B gateway <<var_nodeB_mgmt_gateway>>

Cluster node B name <<var_nodeB>>

ONTAP 9.4 URL <<var_url_boot_software>>

Name for cluster <<var_clustername>>

Cluster management IP address <<var_clustermgmt_ip>>

Cluster B gateway <<var_clustermgmt_gateway>>

Cluster B netmask <<var_clustermgmt_mask>>

Domain name <<var_domain_name>>

DNS server IP (you can enter more than one) <var_dns_server_ip

Page 20: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

20 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Cluster Detail Cluster Detail Value

NTP server IP (you can enter more than one) <<var_ntp_server_ip>>

Configure Node A

To configure node A, complete the following steps:

1. Connect to the storage system console port. You should see a Loader-A prompt. However, if the storage system is in a reboot loop, press Ctrl-C to exit the autoboot loop when you see this message:

Starting AUTOBOOT press Ctrl-C to abort…

2. Allow the system to boot.

autoboot

3. Press Ctrl-C to enter the Boot menu.

Note: If ONTAP 9.4 is not the version of software being booted, continue with the following steps to install new software. If ONTAP 9.4 is the version being booted, select option 8 and y to reboot the node. Then, continue with step 14.

4. To install new software, select option 7.

5. Enter y to perform an upgrade.

6. Select e0M for the network port you want to use for the download.

7. Enter y to reboot now.

8. Enter the IP address, netmask, and default gateway for e0M in their respective places.

<<var_nodeA_mgmt_ip>> <<var_nodeA_mgmt_mask>> <<var_nodeA_mgmt_gateway>>

9. Enter the URL where the software can be found.

Note: This web server must be pingable.

<<var_url_boot_software>>

10. Press Enter for the user name, indicating no user name.

11. Enter y to set the newly installed software as the default to be used for subsequent reboots.

12. Enter y to reboot the node.

Note: When installing new software, the system might perform firmware upgrades to the BIOS and adapter cards, causing reboots and possible stops at the Loader-A prompt. If these actions occur, the system might deviate from this procedure.

13. Press Ctrl-C to enter the Boot menu.

14. Select option 4 for Clean Configuration and Initialize All Disks.

15. Enter y to zero disks, reset config, and install a new file system.

16. Enter y to erase all the data on the disks.

Note: The initialization and creation of the root aggregate can take 90 minutes or more to complete, depending on the number and type of disks attached. When initialization is complete, the storage system reboots. Note that SSDs take considerably less time to initialize. You can continue with the node B configuration while the disks for node A are zeroing.

17. While node A is initializing, begin configuring node B.

Page 21: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

21 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Configure Node B

To configure node B, complete the following steps:

1. Connect to the storage system console port. You should see a Loader-A prompt. However, if the storage system is in a reboot loop, press Ctrl-C to exit the autoboot loop when you see this message:

Starting AUTOBOOT press Ctrl-C to abort…

2. Press Ctrl-C to enter the Boot menu.

autoboot

3. Press Ctrl-C when prompted.

Note: If ONTAP 9.4 is not the version of software being booted, continue with the following steps to install new software. If ONTAP 9.4 is the version being booted, select option 8 and y to reboot the node. Then, continue with step 14.

4. To install new software, select option 7.

5. Enter y to perform an upgrade.

6. Select e0M for the network port you want to use for the download.

7. Enter y to reboot now.

8. Enter the IP address, netmask, and default gateway for e0M in their respective places.

<<var_nodeB_mgmt_ip>> <<var_nodeB_mgmt_ip>><<var_nodeB_mgmt_gateway>>

9. Enter the URL where the software can be found.

Note: This web server must be pingable.

<<var_url_boot_software>>

10. Press Enter for the user name, indicating no user name.

11. Enter y to set the newly installed software as the default to be used for subsequent reboots.

12. Enter y to reboot the node.

Note: When installing new software, the system might perform firmware upgrades to the BIOS and adapter cards, causing reboots and possible stops at the Loader-A prompt. If these actions occur, the system might deviate from this procedure.

13. Press Ctrl-C to enter the Boot menu.

14. Select option 4 for Clean Configuration and Initialize All Disks.

15. Enter y to zero disks, reset config, and install a new file system.

16. Enter y to erase all the data on the disks.

Note: The initialization and creation of the root aggregate can take 90 minutes or more to complete, depending on the number and type of disks attached. When initialization is complete, the storage system reboots. Note that SSDs take considerably less time to initialize.

Continuation Node A Configuration and Cluster Configuration

From a console port program attached to the storage controller A (node A) console port, run the node

setup script. This script appears when ONTAP 9.4 boots on the node for the first time.

Note: The node and cluster setup procedure has changed slightly in ONTAP 9.4. The cluster setup wizard is now used to configure the first node in a cluster, and System Manager is used to configure the cluster.

Page 22: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

22 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

1. Follow the prompts to set up node A.

Welcome to the cluster setup wizard.

You can enter the following commands at any time:

"help" or "?" - if you want to have a question clarified,

"back" - if you want to change previously answered questions, and

"exit" or "quit" - if you want to quit the cluster setup wizard.

Any changes you made before quitting will be saved.

You can return to cluster setup at any time by typing "cluster setup".

To accept a default or omit a question, do not enter a value.

This system will send event messages and periodic reports to NetApp Technical

Support. To disable this feature, enter

autosupport modify -support disable

within 24 hours.

Enabling AutoSupport can significantly speed problem determination and

resolution should a problem occur on your system.

For further information on AutoSupport, see:

http://support.netapp.com/autosupport/

Type yes to confirm and continue {yes}: yes

Enter the node management interface port [e0M]:

Enter the node management interface IP address: <<var_nodeA_mgmt_ip>>

Enter the node management interface netmask: <<var_nodeA_mgmt_mask>>

Enter the node management interface default gateway: <<var_nodeA_mgmt_gateway>>

A node management interface on port e0M with IP address <<var_nodeA_mgmt_ip>> has been created.

Use your web browser to complete cluster setup by accessing

https://<<var_nodeA_mgmt_ip>>

Otherwise, press Enter to complete cluster setup using the command line

interface:

2. Navigate to the IP address of the node’s management interface.

Note: Cluster setup can also be performed by using the CLI. This document describes cluster setup using NetApp System Manager guided setup.

3. Click Guided Setup to configure the cluster.

4. Enter <<var_clustername>> for the cluster name and <<var_nodeA>> and <<var_nodeB>> for

each of the nodes that you are configuring. Enter the password that you would like to use for the storage system. Select Switchless Cluster for the cluster type. Enter the cluster base license.

Page 23: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

23 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5. You can also enter feature licenses for Cluster, NFS, and iSCSI.

6. You see a status message stating the cluster is being created. This status message cycles through several statuses. This process takes several minutes.

7. Configure the network.

a. Deselect the IP Address Range option.

b. Enter <<var_clustermgmt_ip>> in the Cluster Management IP Address field,

<<var_clustermgmt_mask>> in the Netmask field, and <<var_clustermgmt_gateway>>

in the Gateway field. Use the … selector in the Port field to select e0M of node A.

c. The node management IP for node A is already populated. Enter <<var_nodeA_mgmt_ip>>

for node B.

d. Enter <<var_domain_name>> in the DNS Domain Name field. Enter

<<var_dns_server_ip>> in the DNS Server IP Address field.

Note: You can enter multiple DNS server IP addresses.

Page 24: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

24 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

e. Enter <<var_ntp_server_ip>> in the Primary NTP Server field.

Note: You can also enter an alternate NTP server.

8. Configure the support information.

a. If your environment requires a proxy to access AutoSupport, enter the URL in Proxy URL.

b. Enter the SMTP mail host and email address for event notifications.

Note: You must, at a minimum, set up the event notification method before you can proceed. You can select any of the methods.

9. When indicated that the cluster configuration has completed, click Manage Your Cluster to configure the storage.

Continuation of Storage Cluster Configuration

After the configuration of the storage nodes and base cluster, you can continue with the configuration of

the storage cluster.

Zero All Spare Disks

To zero all spare disks in the cluster, run the following command:

disk zerospares

Page 25: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

25 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Set On-Board UTA2 Ports Personality

1. Verify the current mode and the current type of the ports by running the ucadmin show command.

AFF A220::> ucadmin show

Current Current Pending Pending Admin

Node Adapter Mode Type Mode Type Status

------------ ------- ------- --------- ------- --------- -----------

AFF A220_A 0c fc target - - online

AFF A220_A 0d fc target - - online

AFF A220_A 0e fc target - - online

AFF A220_A 0f fc target - - online

AFF A220_B 0c fc target - - online

AFF A220_B 0d fc target - - online

AFF A220_B 0e fc target - - online

AFF A220_B 0f fc target - - online

8 entries were displayed.

2. Verify that the current mode of the ports that are in use is cna and that the current type is set to

target. If not, change the port personality by using the following command:

ucadmin modify -node <home node of the port> -adapter <port name> -mode cna -type target

Note: The ports must be offline to run the previous command. To take a port offline, run the following command:

network fcp adapter modify -node <home node of the port> -adapter <port name> -state down

Note: If you changed the port personality, you must reboot each node for the change to take effect.

Rename Management Logical Interfaces (LIFs)

To rename the management LIFs, complete the following steps:

1. Show the current management LIF names.

network interface show –vserver <<clustername>>

2. Rename the cluster management LIF.

network interface rename –vserver <<clustername>> –lif cluster_setup_cluster_mgmt_lif_1 –newname

cluster_mgmt

3. Rename the node B management LIF.

network interface rename -vserver <<clustername>> -lif cluster_setup_node_mgmt_lif_AFF A220_B_1 -

newname AFF A220-02_mgmt1

Set Auto-Revert on Cluster Management

Set the auto-revert parameter on the cluster management interface.

network interface modify –vserver <<clustername>> -lif cluster_mgmt –auto-revert true

Setting Up Service Processor Network Interface

To assign a static IPv4 address to the service processor on each node, run the following commands:

system service-processor network modify –node <<var_nodeA>> -address-family IPv4 –enable true –

dhcp none –ip-address <<var_nodeA_sp_ip>> -netmask <<var_nodeA_sp_mask>> -gateway

<<var_nodeA_sp_gateway>>

system service-processor network modify –node <<var_nodeB>> -address-family IPv4 –enable true –

dhcp none –ip-address <<var_nodeB_sp_ip>> -netmask <<var_nodeB_sp_mask>> -gateway

<<var_nodeB_sp_gateway>>

Page 26: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

26 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: The service processor IP addresses should be in the same subnet as the node management IP addresses.

Enable Storage Failover in ONTAP

To confirm that storage failover is enabled, run the following commands in a failover pair:

1. Verify the status of storage failover.

storage failover show

Note: Both <<var_nodeA>> and <<var_nodeB>> must be able to perform a takeover. Go to step 3 if the nodes can perform a takeover.

2. Enable failover on one of the two nodes.

storage failover modify -node <<var_nodeA>> -enabled true

Note: Enabling failover on one node enables it for both nodes.

3. Verify the HA status of the two-node cluster.

Note: This step is not applicable for clusters with more than two nodes.

cluster ha show

4. Go to step 6 if high availability is configured. If high availability is configured, you see the following message upon issuing the command:

High Availability Configured: true

5. Enable HA mode only for the two-node cluster.

Note: Do not run this command for clusters with more than two nodes because it causes problems with failover.

cluster ha modify -configured true

Do you want to continue? {y|n}: y

6. Verify that hardware assist is correctly configured and, if needed, modify the partner IP address.

storage failover hwassist show

Note: The message Keep Alive Status : Error: did not receive hwassist keep alive alerts from partner indicates that hardware assist is not configured. Run the following commands to configure hardware assist.

storage failover modify –hwassist-partner-ip <<var_nodeB_mgmt_ip>> -node <<var_nodeA>>

storage failover modify –hwassist-partner-ip <<var_nodeA_mgmt_ip>> -node <<var_nodeB>>

Create Jumbo Frame MTU Broadcast Domain in ONTAP

To create a data broadcast domain with an MTU of 9000, run the following commands:

broadcast-domain create -broadcast-domain Infra_NFS -mtu 9000

broadcast-domain create -broadcast-domain Infra_iSCSI-A -mtu 9000

broadcast-domain create -broadcast-domain Infra_iSCSI-B -mtu 9000

Remove Data Ports from Default Broadcast Domain

The 10GbE data ports are used for iSCSI/NFS traffic, and these ports should be removed from the default

domain. Ports e0e and e0f are not used and should also be removed from the default domain.

To remove the ports from the broadcast domain, run the following command:

Page 27: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

27 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

broadcast-domain remove-ports -broadcast-domain Default -ports <<var_nodeA>>:e0c,

<<var_nodeA>>:e0d, <<var_nodeA>>:e0e, <<var_nodeA>>:e0f, <<var_nodeB>>:e0c, <<var_nodeB>>:e0d,

<<var_nodeA>>:e0e, <<var_nodeA>>:e0f

Disable Flow Control on UTA2 Ports

It is a NetApp best practice to disable flow control on all UTA2 ports that are connected to external

devices. To disable flow control, run the following command:

net port modify -node <<var_nodeA>> -port e0c -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeA>> -port e0d -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeA>> -port e0e -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeA>> -port e0f -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeB>> -port e0c -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeB>> -port e0d -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeB>> -port e0e -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

net port modify -node <<var_nodeB>> -port e0f -flowcontrol-admin none

Warning: Changing the network port settings will cause a several second interruption in carrier.

Do you want to continue? {y|n}: y

Configure IFGRP LACP in ONTAP

This type of interface group requires two or more Ethernet interfaces and a switch that supports LACP.

Make sure the switch is properly configured.

From the cluster prompt, complete the following steps.

ifgrp create -node <<var_nodeA>> -ifgrp a0a -distr-func port -mode multimode_lacp

network port ifgrp add-port -node <<var_nodeA>> -ifgrp a0a -port e0c

network port ifgrp add-port -node <<var_nodeA>> -ifgrp a0a -port e0d

ifgrp create -node << var_nodeB>> -ifgrp a0a -distr-func port -mode multimode_lacp

network port ifgrp add-port -node <<var_nodeB>> -ifgrp a0a -port e0c

network port ifgrp add-port -node <<var_nodeB>> -ifgrp a0a -port e0d

Configure Jumbo Frames in NetApp ONTAP

To configure an ONTAP network port to use jumbo frames (that usually have an MTU of 9,000 bytes), run

the following commands from the cluster shell:

AFF A220::> network port modify -node node_A -port a0a -mtu 9000

Warning: This command will cause a several second interruption of service on

this network port.

Do you want to continue? {y|n}: y

AFF A220::> network port modify -node node_B -port a0a -mtu 9000

Warning: This command will cause a several second interruption of service on

this network port.

Do you want to continue? {y|n}: y

Page 28: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

28 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Create VLANs in ONTAP

To create VLANs in ONTAP, complete the following steps:

1. Create NFS VLAN ports and add them to the data broadcast domain.

network port vlan create –node <<var_nodeA>> -vlan-name a0a-<<var_nfs_vlan_id>>

network port vlan create –node <<var_nodeB>> -vlan-name a0a-<<var_nfs_vlan_id>>

broadcast-domain add-ports -broadcast-domain Infra_NFS -ports <<var_nodeA>>:a0a-

<<var_nfs_vlan_id>>, <<var_nodeB>>:a0a-<<var_nfs_vlan_id>>

2. Create iSCSI VLAN ports and add them to the data broadcast domain.

network port vlan create –node <<var_nodeA>> -vlan-name a0a-<<var_iscsi_vlan_A_id>>

network port vlan create –node <<var_nodeA>> -vlan-name a0a-<<var_iscsi_vlan_B_id>>

network port vlan create –node <<var_nodeB>> -vlan-name a0a-<<var_iscsi_vlan_A_id>>

network port vlan create –node <<var_nodeB>> -vlan-name a0a-<<var_iscsi_vlan_B_id>>

broadcast-domain add-ports -broadcast-domain Infra_iSCSI-A -ports <<var_nodeA>>:a0a-

<<var_iscsi_vlan_A_id>>,<<var_nodeB>>:a0a-<<var_iscsi_vlan_A_id>>

broadcast-domain add-ports -broadcast-domain Infra_iSCSI-B -ports <<var_nodeA>>:a0a-

<<var_iscsi_vlan_B_id>>,<<var_nodeB>>:a0a-<<var_iscsi_vlan_B_id>>

3. Create MGMT-VLAN ports.

network port vlan create –node <<var_nodeA>> -vlan-name a0a-<<mgmt_vlan_id>>

network port vlan create –node <<var_nodeB>> -vlan-name a0a-<<mgmt_vlan_id>>

Create Aggregates in ONTAP

An aggregate containing the root volume is created during the ONTAP setup process. To create

additional aggregates, determine the aggregate name, the node on which to create it, and the number of

disks it contains.

To create aggregates, run the following commands:

aggr create -aggregate aggr1_nodeA -node <<var_nodeA>> -diskcount <<var_num_disks>>

aggr create -aggregate aggr1_nodeB -node <<var_nodeB>> -diskcount <<var_num_disks>>

Note: Retain at least one disk (select the largest disk) in the configuration as a spare. A best practice is to have at least one spare for each disk type and size.

Note: Start with five disks; you can add disks to an aggregate when additional storage is required.

Note: The aggregate cannot be created until disk zeroing completes. Run the aggr show command to display the aggregate creation status. Do not proceed until aggr1_nodeA is online.

Configure Time Zone in ONTAP

To configure time synchronization and to set the time zone on the cluster, run the following command:

timezone <<var_timezone>>

Note: For example, in the eastern United States, the time zone is America/New_York. After you begin typing the time zone name, press the Tab key to see available options.

Configure SNMP in ONTAP

To configure the SNMP, complete the following steps:

1. Configure SNMP basic information, such as the location and contact. When polled, this information is visible as the sysLocation and sysContact variables in SNMP.

snmp contact <<var_snmp_contact>>

snmp location “<<var_snmp_location>>”

snmp init 1

Page 29: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

29 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

options snmp.enable on

2. Configure SNMP traps to send to remote hosts.

snmp traphost add <<var_snmp_server_fqdn>>

Configure SNMPv1 in ONTAP

To configure SNMPv1, set the shared secret plain-text password called a community.

snmp community add ro <<var_snmp_community>>

Note: Use the snmp community delete all command with caution. If community strings are used for other monitoring products, this command removes them.

Configure SNMPv3 in ONTAP

SNMPv3 requires that you define and configure a user for authentication. To configure SNMPv3,

complete the following steps:

1. Run the security snmpusers command to view the engine ID.

2. Create a user called snmpv3user.

security login create -username snmpv3user -authmethod usm -application snmp

3. Enter the authoritative entity's engine ID and select md5 as the authentication protocol.

4. Enter an eight-character minimum-length password for the authentication protocol when prompted.

5. Select des as the privacy protocol.

6. Enter an eight-character minimum-length password for the privacy protocol when prompted.

Configure AutoSupport HTTPS in ONTAP

The NetApp AutoSupport tool sends support summary information to NetApp through HTTPS. To

configure AutoSupport, run the following command:

system node autosupport modify -node * -state enable –mail-hosts <<var_mailhost>> -transport

https -support enable -noteto <<var_storage_admin_email>>

Create a Storage Virtual Machine

To create an infrastructure storage virtual machine (SVM), complete the following steps:

1. Run the vserver create command.

vserver create –vserver Infra-SVM –rootvolume rootvol –aggregate aggr1_nodeA –rootvolume-

security-style unix

2. Add the data aggregate to the infra-SVM aggregate list for the NetApp VSC.

vserver modify -vserver Infra-SVM -aggr-list aggr1_nodeA,aggr1_nodeB

3. Remove the unused storage protocols from the SVM, leaving NFS and iSCSI.

vserver remove-protocols –vserver Infra-SVM -protocols cifs,ndmp,fcp

4. Enable and run the NFS protocol in the infra-SVM SVM.

nfs create -vserver Infra-SVM -udp disabled

5. Turn on the SVM vstorage parameter for the NetApp NFS VAAI plug-in. Then, verify that NFS has

been configured.

vserver nfs modify –vserver Infra-SVM –vstorage enabled

vserver nfs show

Page 30: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

30 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: Commands are prefaced by vserver in the command line because storage virtual machines were previously called servers.

Configure NFSv3 in ONTAP

Table 11 lists the information needed to complete this configuration.

Table 11) Information required for NFS configuration.

Detail Detail Value

ESXi host A NFS IP address <<var_esxi_hostA_nfs_ip>>

ESXi host B NFS IP address <<var_esxi_hostB_nfs_ip>>

To configure NFS on the SVM, run the following commands:

1. Create a rule for each ESXi host in the default export policy.

2. For each ESXi host being created, assign a rule. Each host has its own rule index. Your first ESXi host has rule index 1, your second ESXi host has rule index 2, and so on.

vserver export-policy rule create –vserver Infra-SVM -policyname default –ruleindex 1 –protocol

nfs -clientmatch <<var_esxi_hostA_nfs_ip>> -rorule sys –rwrule sys -superuser sys –allow-suid

false

vserver export-policy rule create –vserver Infra-SVM -policyname default –ruleindex 2 –protocol

nfs -clientmatch <<var_esxi_hostB_nfs_ip>> -rorule sys –rwrule sys -superuser sys –allow-suid

false

vserver export-policy rule show

3. Assign the export policy to the infrastructure SVM root volume.

volume modify –vserver Infra-SVM –volume rootvol –policy default

Note: The NetApp VSC automatically handles export policies if you choose to install it after vSphere has been set up. If you do not install it, you must create export policy rules when additional Cisco UCS C-Series servers are added.

Creating iSCSI Service in ONTAP

To create the iSCSI service, complete the following step:

1. Create the iSCSI service on the SVM. This command also starts the iSCSI service and sets the iSCSI IQN for the SVM. Verify that iSCSI has been configured.

iscsi create -vserver Infra-SVM

iscsi show

Creating Load-Sharing Mirror of SVM Root Volume in ONTAP

1. Create a volume to be the load-sharing mirror of the infrastructure SVM root volume on each node.

volume create –vserver Infra_Vserver –volume rootvol_m01 –aggregate aggr1_nodeA –size 1GB –type

DP

volume create –vserver Infra_Vserver –volume rootvol_m02 –aggregate aggr1_nodeB –size 1GB –type

DP

2. Create a job schedule to update the root volume mirror relationships every 15 minutes.

job schedule interval create -name 15min -minutes 15

3. Create the mirroring relationships.

snapmirror create -source-path Infra-SVM:rootvol -destination-path Infra-SVM:rootvol_m01 -type LS

-schedule 15min

Page 31: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

31 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

snapmirror create -source-path Infra-SVM:rootvol -destination-path Infra-SVM:rootvol_m02 -type LS

-schedule 15min

4. Initialize the mirroring relationship and verify that it has been created.

snapmirror initialize-ls-set -source-path Infra-SVM:rootvol

snapmirror show

Configure HTTPS Access in ONTAP

To configure secure access to the storage controller, complete the following steps:

1. Increase the privilege level to access the certificate commands.

set -privilege diag

Do you want to continue? {y|n}: y

2. Generally, a self-signed certificate is already in place. Verify the certificate by running the following command:

security certificate show

3. For each SVM shown, the certificate common name should match the DNS FQDN of the SVM. The four default certificates should be deleted and replaced by either self-signed certificates or certificates from a certificate authority.

Note: Deleting expired certificates before creating certificates is a best practice. Run the security certificate delete command to delete expired certificates. In the following command, use TAB completion to select and delete each default certificate.

security certificate delete [TAB] …

Example: security certificate delete -vserver Infra-SVM -common-name Infra-SVM -ca Infra-SVM -

type server -serial 552429A6

4. To generate and install self-signed certificates, run the following commands as one-time commands. Generate a server certificate for the infra-SVM and the cluster SVM. Again, use TAB completion to aid in completing these commands.

security certificate create [TAB] …

Example: security certificate create -common-name infra-svm.netapp.com -type server -size 2048 -

country US -state "North Carolina" -locality "RTP" -organization "NetApp" -unit "FlexPod" -email-

addr "[email protected]" -expire-days 365 -protocol SSL -hash-function SHA256 -vserver Infra-SVM

5. To obtain the values for the parameters required in the following step, run the security

certificate show command.

6. Enable each certificate that was just created using the –server-enabled true and –client-

enabled false parameters. Again, use TAB completion.

security ssl modify [TAB] …

Example: security ssl modify -vserver Infra-SVM -server-enabled true -client-enabled false -ca

infra-svm.netapp.com -serial 55243646 -common-name infra-svm.netapp.com

7. Configure and enable SSL and HTTPS access and disable HTTP access.

system services web modify -external true -sslv3-enabled true

Warning: Modifying the cluster configuration will cause pending web service requests to be

interrupted as the web servers are restarted.

Do you want to continue {y|n}: y

system services firewall policy delete -policy mgmt -service http –vserver <<var_clustername>>

Note: It is normal for some of these commands to return an error message stating that the entry does not exist.

8. Revert to the admin privilege level and create the setup to allow SVM to be available by the web.

set –privilege admin

vserver services web modify –name spi|ontapi|compat –vserver * -enabled true

Page 32: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

32 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Create a NetApp FlexVol Volume in ONTAP

To create a NetApp FlexVol® volume, enter the volume name, size, and the aggregate on which it exists.

Create two VMware datastore volumes and a server boot volume.

volume create -vserver Infra-SVM -volume infra_datastore_1 -aggregate aggr1_nodeA -size 500GB -

state online -policy default -junction-path /infra_datastore_1 -space-guarantee none -percent-

snapshot-space 0

volume create -vserver Infra-SVM -volume infra_swap -aggregate aggr1_nodeA -size 100GB -state

online -policy default -junction-path /infra_swap -space-guarantee none -percent-snapshot-space 0

-snapshot-policy none

volume create -vserver Infra-SVM -volume esxi_boot -aggregate aggr1_nodeA -size 100GB -state

online -policy default -space-guarantee none -percent-snapshot-space 0

Enable Deduplication in ONTAP

To enable deduplication on appropriate volumes, run the following commands:

volume efficiency on –vserver Infra-SVM -volume infra_datastore_1

volume efficiency on –vserver Infra-SVM -volume esxi_boot

Create LUNs in ONTAP

To create two boot LUNs, run the following commands:

lun create -vserver Infra-SVM -volume esxi_boot -lun VM-Host-Infra-A -size 15GB -ostype vmware -

space-reserve disabled

lun create -vserver Infra-SVM -volume esxi_boot -lun VM-Host-Infra-B -size 15GB -ostype vmware -

space-reserve disabled

Note: When adding an extra Cisco UCS C-Series server, an extra boot LUN must be created.

Create iSCSI LIFs in ONTAP

Table 12 lists the information needed to complete this configuration.

Table 12) Information required for iSCSI configuration.

Detail Detail Value

Storage node A iSCSI LIF01A <<var_nodeA_iscsi_lif01a_ip>>

Storage node A iSCSI LIF01A network mask <<var_nodeA_iscsi_lif01a_mask>>

Storage node A iSCSI LIF01B <<var_nodeA_iscsi_lif01b_ip>>

Storage node A iSCSI LIF01B network mask <<var_nodeA_iscsi_lif01b_mask>>

Storage node B iSCSI LIF01A <<var_nodeB_iscsi_lif01a_ip>>

Storage node B iSCSI LIF01A network mask <<var_nodeB_iscsi_lif01a_mask>>

Storage node B iSCSI LIF01B <<var_nodeB_iscsi_lif01b_ip>>

Storage node B iSCSI LIF01B network mask <<var_nodeB_iscsi_lif01b_mask>>

1. Create four iSCSI LIFs, two on each node.

network interface create -vserver Infra-SVM -lif iscsi_lif01a -role data -data-protocol iscsi -

home-node <<var_nodeA>> -home-port a0a-<<var_iscsi_vlan_A_id>> -address

<<var_nodeA_iscsi_lif01a_ip>> -netmask <<var_nodeA_iscsi_lif01a_mask>> –status-admin up –

failover-policy disabled –firewall-policy data –auto-revert false

Page 33: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

33 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

network interface create -vserver Infra-SVM -lif iscsi_lif01b -role data -data-protocol iscsi -

home-node <<var_nodeA>> -home-port a0a-<<var_iscsi_vlan_B_id>> -address

<<var_nodeA_iscsi_lif01b_ip>> -netmask <<var_nodeA_iscsi_lif01b_mask>> –status-admin up –

failover-policy disabled –firewall-policy data –auto-revert false

network interface create -vserver Infra-SVM -lif iscsi_lif02a -role data -data-protocol iscsi -

home-node <<var_nodeB>> -home-port a0a-<<var_iscsi_vlan_A_id>> -address

<<var_nodeB_iscsi_lif01a_ip>> -netmask <<var_nodeB_iscsi_lif01a_mask>> –status-admin up –

failover-policy disabled –firewall-policy data –auto-revert false

network interface create -vserver Infra-SVM -lif iscsi_lif02b -role data -data-protocol iscsi -

home-node <<var_nodeB>> -home-port a0a-<<var_iscsi_vlan_B_id>> -address

<<var_nodeB_iscsi_lif01b_ip>> -netmask <<var_nodeB_iscsi_lif01b_mask>> –status-admin up –

failover-policy disabled –firewall-policy data –auto-revert false

network interface show

Create NFS LIFs in ONTAP

Table 13 lists the information needed to complete this configuration.

Table 13) Information required for NFS configuration.

Detail Detail Value

Storage node A NFS LIF 01 IP <<var_nodeA_nfs_lif_01_ip>>

Storage node A NFS LIF 01 network mask <<var_nodeA_nfs_lif_01_mask>>

Storage node B NFS LIF 02 IP <<var_nodeB_nfs_lif_02_ip>>

Storage node B NFS LIF 02 network mask <<var_nodeB_nfs_lif_02_mask>>

1. Create an NFS LIF.

network interface create -vserver Infra-SVM -lif nfs_lif01 -role data -data-protocol nfs -home-

node <<var_nodeA>> -home-port a0a-<<var_nfs_vlan_id>> –address <<var_nodeA_nfs_lif_01_ip>> -

netmask << var_nodeA_nfs_lif_01_mask>> -status-admin up –failover-policy broadcast-domain-wide –

firewall-policy data –auto-revert true

network interface create -vserver Infra-SVM -lif nfs_lif02 -role data -data-protocol nfs -home-

node <<var_nodeA>> -home-port a0a-<<var_nfs_vlan_id>> –address <<var_nodeB_nfs_lif_02_ip>> -

netmask << var_nodeB_nfs_lif_02_mask>> -status-admin up –failover-policy broadcast-domain-wide –

firewall-policy data –auto-revert true

network interface show

Add Infrastructure SVM Administrator

Table 14 lists the information needed to complete this configuration.

Table 14) Information required for SVM administrator addition.

Detail Detail Value

Vsmgmt IP <<var_svm_mgmt_ip>>

Vsmgmt network mask <<var_svm_mgmt_mask>>

Vsmgmt default gateway <<var_svm_mgmt_gateway>>

Page 34: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

34 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

To add the infrastructure SVM administrator and SVM administration logical interface to the management

network, complete the following steps:

1. Run the following command:

network interface create –vserver Infra-SVM –lif vsmgmt –role data –data-protocol none –home-node

<<var_nodeB>> -home-port e0M –address <<var_svm_mgmt_ip>> -netmask <<var_svm_mgmt_mask>> -

status-admin up –failover-policy broadcast-domain-wide –firewall-policy mgmt –auto-revert true

Note: The SVM management IP here should be in the same subnet as the storage cluster management IP.

2. Create a default route to allow the SVM management interface to reach the outside world.

network route create –vserver Infra-SVM -destination 0.0.0.0/0 –gateway <<var_svm_mgmt_gateway>>

network route show

3. Set a password for the SVM vsadmin user and unlock the user.

security login password –username vsadmin –vserver Infra-SVM

Enter a new password: <<var_password>>

Enter it again: <<var_password>>

security login unlock –username vsadmin –vserver Infra-SVM

5.3 Cisco UCS C-Series Rack Server Deployment Procedure

The following section provides a detailed procedure for configuring a Cisco UCS C-Series standalone

rack server for use in the FlexPod Express configuration.

Perform Initial Cisco UCS C-Series Standalone Server Setup for Cisco Integrated Management Server

Complete these steps for the initial setup of the CIMC interface for Cisco UCS C-Series standalone

servers.

Table 15 lists the information needed to configure CIMC for each Cisco UCS C-Series standalone server.

Table 15) Information required for CIMC configuration.

Detail Detail Value

CIMC IP address <<cimc_ip>>

CIMC subnet mask <<cimc_netmask

CIMC default gateway <<cimc_gateway>>

Note: The CIMC version used in this validation is CIMC 3.1.3(g)

All Servers

1. Attach the Cisco keyboard, video, and mouse (KVM) dongle (provided with the server) to the KVM port on the front of the server. Plug a VGA monitor and USB keyboard into the appropriate KVM dongle ports.

2. Power on the server and press F8 when prompted to enter the CIMC configuration.

Page 35: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

35 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3. In the CIMC configuration utility, set the following options:

• Network interface card (NIC) mode:

− Dedicated [X]

• IP (Basic):

− IPV4: [X]

− DHCP enabled: [ ]

− CIMC IP: <<cimc_ip>>

− Prefix/Subnet: <<cimc_netmask>>

− Gateway: <<cimc_gateway>>

• VLAN (Advanced): Leave cleared to disable VLAN tagging.

− NIC redundancy

− None: [X]

Page 36: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

36 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

4. Press F1 to see additional settings.

• Common properties:

− Host name: <<esxi_host_name>>

− Dynamic DNS: [ ]

− Factory defaults: Leave cleared.

• Default user (basic):

− Default password: <<admin_password>>

− Reenter password: <<admin_password>>

− Port properties: Use default values.

− Port profiles: Leave cleared.

Page 37: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

37 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5. Press F10 to save the CIMC interface configuration.

6. After the configuration is saved, press Esc to exit.

Configure Cisco UCS C-Series Servers iSCSI Boot

In this FlexPod Express configuration, the VIC1387 is used for iSCSI boot.

Table 16 lists the information needed to configure iSCSI boot.

Note: Italicized font indicates variables that are unique for each ESXi host.

Table 16) Information required for iSCSI boot configuration.

Detail Detail Value

ESXi host initiator A name <<var_ucs_initiator_name_A>>

ESXi host iSCSI-A IP <<var_esxi_host_iscsiA_ip>>

ESXi host iSCSI-A network mask <<var_esxi_host_iscsiA_mask>>

ESXi host iSCSI A default gateway <<var_esxi_host_iscsiA_gateway>>

ESXi host initiator B name <<var_ucs_initiator_name_B>>

ESXi host iSCSI-B IP <<var_esxi_host_iscsiB_ip>>

Page 38: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

38 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Detail Detail Value

ESXi host iSCSI-B network mask <<var_esxi_host_iscsiB_mask>>

ESXi host iSCSI-B gateway <<var_esxi_host_iscsiB_gateway>>

IP address iscsi_lif01a

IP address iscsi_lif02a

IP address iscsi_lif01b

IP address iscsi_lif02b

Infra_SVM IQN

Boot Order Configuration

To set the boot order configuration, complete the following steps:

1. From the CIMC interface browser window, click the Server tab and select BIOS.

2. Click Configure Boot Order and then click OK.

3. Configure the following devices by clicking the device under Add Boot Device, and going to the Advanced tab.

• Add Virtual Media

− Name: KVM-CD-DVD

− Subtype: KVM MAPPED DVD

− State: Enabled

− Order: 1

• Add iSCSI Boot.

− Name: iSCSI-A

− State: Enabled

Page 39: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

39 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

− Order: 2

− Slot: MLOM

− Port: 0

• Click Add iSCSI Boot.

− Name: iSCSI-B

− State: Enabled

− Order: 3

− Slot: MLOM

− Port: 1

4. Click Add Device.

5. Click Save Changes and then click Close.

6. Reboot the server to boot with your new boot order.

Disable RAID Controller (If Present)

Complete the following steps if your C-Series server contains a RAID controller. A RAID controller is not

needed in the boot from SAN configuration. Optionally, you can also physically remove the RAID

controller from the server.

1. Click BIOS on the left navigation pane in CIMC.

2. Select Configure BIOS.

3. Scroll down to PCIe Slot:HBA Option ROM.

4. If the value is not already disabled, set it to disabled.

Page 40: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

40 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Configure Cisco VIC1387 for iSCSI Boot

The following configuration steps are for the Cisco VIC 1387 for iSCSI boot.

Create iSCSI vNICs

1. Click Add to create a vNIC.

2. In the Add vNIC section, enter the following settings:

− Name: iSCSI-vNIC-A

− MTU: 9000

− Default VLAN: <<var_iscsi_vlan_a>>

− VLAN Mode: TRUNK

− Enable PXE boot: Check

3. Click Add vNIC and then click OK.

4. Repeat the process to add a second vNIC.

Page 41: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

41 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

a. Name the vNIC iSCSI-vNIC-B.

b. Enter <<var_iscsi_vlan_b>> as the VLAN.

c. Set the uplink port to 1.

5. Select the vNIC iSCSI-vNIC-A on the left.

6. Under iSCSI Boot Properties, enter the initiator details:

− Name: <<var_ucsa_initiator_name_a>>

− IP address: <<var_esxi_hostA_iscsiA_ip>>

− Subnet mask: <<var_esxi_hostA_iscsiA_mask>>

− Gateway: <<var_esxi_hostA_iscsiA_gateway>>

7. Enter the primary target details.

− Name: IQN number of infra-SVM

− IP address: IP address of iscsi_lif01a

− Boot LUN: 0

8. Enter the secondary target details.

Page 42: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

42 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

− Name: IQN number of infra-SVM

− IP address: IP address of iscsi_lif02a

− Boot LUN: 0

Note: You can obtain the storage IQN number by running the vserver iscsi show command.

Note: Be sure to record the IQN names for each vNIC. You need them for a later step.

9. Click Configure iSCSI.

10. Select the vNIC iSCSI-vNIC-B and click the iSCSI Boot button located on the top of the Host

Ethernet Interfaces section.

11. Repeat the process to configure iSCSI-vNIC-B.

12. Enter the initiator details.

− Name: <<var_ucsa_initiator_name_b>>

− IP address: <<var_esxi_hostb_iscsib_ip>>

− Subnet mask: <<var_esxi_hostb_iscsib_mask>>

− Gateway: <<var_esxi_hostb_iscsib_gateway>>

13. Enter the primary target details.

− Name: IQN number of infra-SVM

− IP address: IP address of iscsi_lif01b

− Boot LUN: 0

14. Enter the secondary target details.

− Name: IQN number of infra-SVM

− IP address: IP address of iscsi_lif02b

− Boot LUN: 0

Note: You can obtain the storage IQN number by using the vserver iscsi show command.

Note: Be sure to record the IQN names for each vNIC. You need them for a later step.

15. Click Configure ISCSI.

Page 43: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

43 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

16. Repeat this process to configure iSCSI boot for Cisco UCS server B.

Configure vNICs for ESXi

1. From the CIMC interface browser window, click Inventory and then click Cisco VIC adapters on the right pane.

2. Under Adapter Cards, select Cisco UCS VIC 1387 and then select the vNICs underneath.

3. Select eth0 and click Properties.

4. Set the MTU to 9000. Click Save Changes.

5. Repeat steps 3 and 4 for eth1, verifying that the uplink port is set to 1 for eth1.

Page 44: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

44 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: This procedure must be repeated for each initial Cisco UCS Server node and each additional Cisco UCS Server node added to the environment.

5.4 NetApp AFF Storage Deployment Procedure (Part 2)

ONTAP SAN Boot Storage Setup

Create iSCSI Igroups

To create igroups, complete the following step:

Note: You need the iSCSI initiator IQNs from the server configuration for this step.

1. From the cluster management node SSH connection, run the following commands. To view the three igroups created in this step, run the igroup show command.

igroup create –vserver Infra-SVM –igroup VM-Host-Infra-A –protocol iscsi –ostype vmware –

initiator <<var_vm_host_infra_a_iSCSI-A_vNIC_IQN>>,<<var_vm_host_infra_a_iSCSI-B_vNIC_IQN>>

igroup create –vserver Infra-SVM –igroup VM-Host-Infra-B –protocol iscsi –ostype vmware –

initiator <<var_vm_host_infra_b_iSCSI-A_vNIC_IQN>>,<<var_vm_host_infra_b_iSCSI-B_vNIC_IQN>>

Note: This step must be completed when adding additional Cisco UCS C-Series servers.

Map Boot LUNs to Igroups

To map boot LUNs to igroups, run the following commands from the cluster management SSH

connection:

lun map –vserver Infra-SVM –volume esxi_boot –lun VM-Host-Infra-A –igroup VM-Host-Infra-A –lun-id

0

lun map –vserver Infra-SVM –volume esxi_boot –lun VM-Host-Infra-B –igroup VM-Host-Infra-B –lun-id

0

Note: This step must be completed when adding additional Cisco UCS C-Series servers.

Page 45: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

45 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5.5 VMware vSphere 6.7 Deployment Procedure

This section provides detailed procedures for installing VMware ESXi 6.7 in a FlexPod Express

configuration. The deployment procedures that follow are customized to include the environment

variables described in previous sections.

Multiple methods exist for installing VMware ESXi in such an environment. This procedure uses the virtual

KVM console and virtual media features of the CIMC interface for Cisco UCS C-Series servers to map

remote installation media to each individual server.

Note: This procedure must be completed for Cisco UCS server A and Cisco UCS server B.

Note: This procedure must be completed for any additional nodes added to the cluster.

Log in to CIMC Interface for Cisco UCS C-Series Standalone Servers

The following steps detail the method for logging in to the CIMC interface for Cisco UCS C-Series

standalone servers. You must log in to the CIMC interface to run the virtual KVM, which enables the

administrator to begin installation of the operating system through remote media.

All Hosts

1. Navigate to a web browser and enter the IP address for the CIMC interface for the Cisco UCS C-Series. This step launches the CIMC GUI application.

2. Log in to the CIMC UI using the admin user name and credentials.

3. In the main menu, select the Server tab.

4. Click Launch KVM Console.

5. From the virtual KVM console, select the Virtual Media tab.

6. Select Map CD/DVD.

Note: You might first need to click Activate Virtual Devices. Select Accept This Session if prompted.

7. Browse to the VMware ESXi 6.7 installer ISO image file and click Open. Click Map Device.

8. Select the Power menu and choose Power Cycle System (Cold Boot). Click Yes.

Installing VMware ESXi

The following steps describe how to install VMware ESXi on each host.

Download ESXI 6.7 Cisco Custom Image

1. Navigate to the VMware vSphere download page for custom ISOs.

2. Click Go to Downloads next to the Cisco Custom Image for ESXi 6.7 GA Install CD.

3. Download the Cisco Custom Image for ESXi 6.7 GA Install CD (ISO).

All Hosts

1. When the system boots, the machine detects the presence of the VMware ESXi installation media.

2. Select the VMware ESXi installer from the menu that appears.

The installer loads. This takes several minutes.

3. After the installer has finished loading, press Enter to continue with the installation.

Page 46: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

46 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

4. After reading the end-user license agreement, accept it and continue with the installation by pressing F11.

5. Select the NetApp LUN that was previously set up as the installation disk for ESXi, and press Enter to continue with the installation.

6. Select the appropriate keyboard layout and press Enter.

7. Enter and confirm the root password and press Enter.

8. The installer warns you that existing partitions are removed on the volume. Continue with the installation by pressing F11. The server reboots after the installation of ESXi.

Set up VMware ESXi Host Management Networking

The following steps describe how to add the management network for each VMware ESXi host.

All Hosts

1. After the server has finished rebooting, enter the option to customize the system by pressing F2.

2. Log in with root as the login name and the root password previously entered during the installation process.

3. Select the Configure Management Network option.

4. Select Network Adapters and press Enter.

5. Select the desired ports for vSwitch0. Press Enter.

Note: Select the ports that correspond to eth0 and eth1 in CIMC.

Page 47: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

47 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

6. Select VLAN (optional) and press Enter.

7. Enter the VLAN ID <<mgmt_vlan_id>>. Press Enter.

8. From the Configure Management Network menu, select IPv4 Configuration to configure the IP address of the management interface. Press Enter.

9. Use the arrow keys to highlight Set Static IPv4 address and use the space bar to select this option.

10. Enter the IP address for managing the VMware ESXi host <<esxi_host_mgmt_ip>>.

11. Enter the subnet mask for the VMware ESXi host <<esxi_host_mgmt_netmask>>.

12. Enter the default gateway for the VMware ESXi host <<esxi_host_mgmt_gateway>>.

13. Press Enter to accept the changes to the IP configuration.

14. Enter the IPv6 configuration menu.

15. Use the space bar to disable IPv6 by unselecting the Enable IPv6 (restart required) option. Press Enter.

16. Enter the menu to configure the DNS settings.

17. Because the IP address is assigned manually, the DNS information must also be entered manually.

18. Enter the primary DNS server’s IP address <<nameserver_ip>>.

19. (Optional) Enter the secondary DNS server’s IP address.

20. Enter the FQDN for the VMware ESXi host name: <<esxi_host_fqdn>>.

21. Press Enter to accept the changes to the DNS configuration.

22. Exit the Configure Management Network submenu by pressing Esc.

23. Press Y to confirm the changes and reboot the server.

24. Log out of the VMware Console by pressing Esc.

Page 48: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

48 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Configure ESXi Host

You need the following information to configure each ESXi host.

Table 17) Information required for configuring ESXi hosts.

Detail Value

ESXi host name

ESXi host management IP

ESXi host management mask

ESXi host management gateway

ESXi host NFS IP

ESXi host NFS mask

ESXi host NFS gateway

ESXi host vMotion IP

ESXi host vMotion mask

ESXi host vMotion gateway

ESXi host iSCSI-A IP

ESXi host iSCSI-A mask

ESXi host iSCSI-A gateway

ESXi host iSCSI-B IP

ESXi host iSCSI-B mask

ESXi host iSCSI-B gateway

Log in to ESXi Host

1. Open the host’s management IP address in a web browser.

2. Log in to the ESXi host using the root account and the password you specified during the install process.

3. Read the statement about the VMware Customer Experience Improvement Program. After selecting the proper response, click OK.

Configure iSCSI Boot

1. Select Networking on the left.

2. On the right, select the Virtual Switches tab.

Page 49: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

49 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3. Click iScsiBootvSwitch.

4. Select Edit settings.

5. Change the MTU to 9000 and click Save.

6. Click Networking in the left navigation pane to return to the Virtual Switches tab.

7. Click Add Standard Virtual Switch.

8. Provide the name iScsiBootvSwitch-B for the vSwitch name.

− Set the MTU to 9000.

− Select vmnic3 from the Uplink 1 options.

− Click Add.

Note: Vmnic2 and vmnic3 are used for iSCSI boot in this configuration. If you have additional NICs in your ESXi host, you might have different vmnic numbers. To confirm which NICs are used for iSCSI boot, match the MAC addresses on the iSCSI vNICs in CIMC to the vmnics in ESXi.

9. In the center pane, select the VMkernel NICs tab.

10. Select Add VMkernel NIC.

a. Specify a new port group name of iScsiBootPG-B.

b. Select iScsiBootvSwitch-B for the virtual switch.

c. Enter <<iscsib_vlan_id>> for the VLAN ID.

d. Change the MTU to 9000.

e. Expand IPv4 Settings.

f. Select Static Configuration.

g. Enter <<var_hosta_iscsib_ip>> for Address.

h. Enter <<var_hosta_iscsib_mask>> for Subnet Mask.

i. Click Create.

Page 50: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

50 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: Set the MTU to 9000 on iScsiBootPG-A.

Configure iSCSI Multipathing

To set up iSCSI multipathing on the ESXi hosts, complete the following steps:

1. Select Storage in the left navigation pane. Click Adapters.

2. Select the iSCSI software adapter and click Configure iSCSI.

3. Under Dynamic Targets, click Add Dynamic Target.

Page 51: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

51 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

4. Enter the IP address iscsi_lif01a.

a. Repeat with the IP addresses iscsi_lif01b, iscsi_lif02a, and iscsi_lif02b.

b. Click Save Configuration.

Note: You can find the iSCSI LIF IP addresses by running the network interface show command on the NetApp cluster or by looking at the Network Interfaces tab in OnCommand® System Manager.

Configure ESXi Host

1. In the left navigation pane, select Networking.

2. Select vSwitch0.

Page 52: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

52 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3. Select Edit Settings.

4. Change the MTU to 9000.

5. Expand NIC Teaming and verify that both vmnic0 and vmnic1 are set to active.

Configure Port Groups and VMkernel NICs

1. In the left navigation pane, select Networking.

2. Right-click the Port Groups tab.

3. Right-click VM Network and select Edit. Change the VLAN ID to <<var_vm_traffic_vlan>>.

4. Click Add Port Group.

a. Name the port group MGMT-Network.

b. Enter <<mgmt_vlan>> for the VLAN ID.

c. Make sure that vSwitch0 is selected.

d. Click Add.

5. Click the VMkernel NICs tab.

Page 53: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

53 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

6. Select Add VMkernel NIC.

a. Select New Port Group.

b. Name the port group NFS-Network.

c. Enter <<nfs_vlan_id>> for the VLAN ID.

d. Change the MTU to 9000.

e. Expand IPv4 Settings.

f. Select Static Configuration.

g. Enter <<var_hosta_nfs_ip>> for Address.

h. Enter <<var_hosta_nfs_mask>> for Subnet Mask.

i. Click Create.

7. Repeat this process to create the vMotion VMkernel port.

8. Select Add VMkernel NIC.

a. Select New Port Group.

b. Name the port group vMotion.

c. Enter <<vmotion_vlan_id>> for the VLAN ID.

d. Change the MTU to 9000.

Page 54: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

54 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

e. Expand IPv4 Settings.

f. Select Static Configuration.

g. Enter <<var_hosta_vmotion_ip>> for Address.

h. Enter <<var_hosta_vmotion_mask>> for Subnet Mask.

i. Make sure that the vMotion checkbox is selected after IPv4 Settings.

Note: There are many ways to configure ESXi networking, including by using the VMware vSphere distributed switch if your licensing allows it. Alternative network configurations are supported in FlexPod Express if they are required to meet business requirements.

Mount First Datastores

The first datastores to be mounted are the infra_datastore_1 datastore for virtual machines and the

infra_swap datastore for virtual machine swap files.

1. Click Storage in the left navigation pane, and then click New Datastore.

2. Select Mount NFS Datastore.

Page 55: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

55 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3. Next, enter the following information in the Provide NFS Mount Details page:

− Name: infra_datastore_1

− NFS server: <<var_nodea_nfs_lif>>

− Share: /infra_datastore_1

− Make sure that NFS 3 is selected.

4. Click Finish. You can see the task completing in the Recent Tasks pane.

5. Repeat this process to mount the infra_swap datastore:

− Name: infra_swap

− NFS server: <<var_nodea_nfs_lif>>

− Share: /infra_swap

− Make sure that NFS 3 is selected.

Configure NTP

To configure NTP for an ESXi host, complete the following steps:

1. Click Manage in the left navigation pane. Select System in the right pane and then click Time & Date.

2. Select Use Network Time Protocol (Enable NTP Client).

3. Select Start and Stop with Host as the NTP service startup policy.

4. Enter <<var_ntp>> as the NTP server. You can set multiple NTP servers.

Page 56: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

56 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5. Click Save.

Move the Virtual Machine Swap-File Location

These steps provide details for moving the virtual machine swap-file location.

1. Click Manage in the left navigation pane. Select system in the right pane, then click Swap.

2. Click Edit Settings. Select infra_swap from the Datastore options.

Page 57: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

57 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

3. Click Save.

Installing the NetApp NFS Plug-in 1.0.20 for VMware VAAI

To install the NetApp NFS Plug-in 1.0.20 for VMware VAAI, complete the following steps.

1. Enter the following commands to verify that VAAI is enabled:

esxcfg-advcfg -g /DataMover/HardwareAcceleratedMove

esxcfg-advcfg -g /DataMover/HardwareAcceleratedInit

If VAAI is enabled, these commands produce the following output:

~ # esxcfg-advcfg -g /DataMover/HardwareAcceleratedMove

Value of HardwareAcceleratedMove is 1

~ # esxcfg-advcfg -g /DataMover/HardwareAcceleratedInit

Value of HardwareAcceleratedInit is 1

2. If VAAI is not enabled, enter the following commands to enable VAAI:

esxcfg-advcfg -s 1 /DataMover/HardwareAcceleratedInit

esxcfg-advcfg -s 1 /DataMover/HardwareAcceleratedMove

These commands produce the following output:

~ # esxcfg-advcfg -s 1 /Data Mover/HardwareAcceleratedInit

Value of HardwareAcceleratedInit is 1

~ # esxcfg-advcfg -s 1 /DataMover/HardwareAcceleratedMove

Value of HardwareAcceleratedMove is 1

3. Download the NetApp NFS Plug-in for VMware VAAI:

a. Go to the software download page at https://mysupport.netapp.com/NOW/download/software/nfs_plugin_vaai_esxi6/1.1.2/.

b. Scroll down and click NetApp NFS Plug-in for VMware VAAI.

c. Select the ESXi platform.

d. Download either the offline bundle (.zip) or online bundle (.vib) of the most recent plug-in.

4. Install the plug-in on the ESXi host by using the ESX CLI.

5. Reboot the ESXI host.

Page 58: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

58 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

5.6 Install VMware vCenter Server 6.7

This section provides detailed procedures for installing VMware vCenter Server 6.7 in a FlexPod Express

configuration.

Note: FlexPod Express uses the VMware vCenter Server Appliance (VCSA).

Download the VMware vCenter Server Appliance

1. Download the VCSA. Access the download link by clicking the Get vCenter Server icon when managing the ESXi host.

2. Download the VCSA from the VMware site.

Note: Although the Microsoft Windows vCenter Server installable is supported, VMware recommends the VCSA for new deployments.

3. Mount the ISO image.

4. Navigate to the vcsa-ui-installer> win32 directory. Double-click installer.exe.

5. Click Install.

6. Click Next on the Introduction page.

7. Accept the end-user license agreement.

8. Select Embedded Platform Services Controller as the deployment type.

Page 59: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

59 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Note: If required, the External Platform Services Controller deployment is also supported as part of the FlexPod Express solution.

9. In the Appliance Deployment Target, enter the IP address of an ESXi host you have deployed, and the root user name and root password.

10. Set the appliance VM by entering VCSA as the VM name and the root password you would like to use

for the VCSA.

Page 60: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

60 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

11. Select the deployment size that best fits your environment. Click Next.

12. Select the infra_datastore_1 datastore. Click Next.

Page 61: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

61 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

13. Enter the following information in the Configure network settings page and click Next.

a. Select MGMT-Network for Network.

b. Enter the FQDN or IP to be used for the VCSA.

c. Enter the IP address to be used.

d. Enter the subnet mask to be used.

e. Enter the default gateway.

f. Enter the DNS server.

14. On the Ready to Complete Stage 1 page, verify that the settings you have entered are correct. Click Finish.

Page 62: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

62 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

The VCSA installs now. This process takes several minutes.

15. After stage 1 completes, a message appears stating that it has completed. Click Continue to begin stage 2 configuration.

16. On the Stage 2 Introduction page, click Next.

17. Enter <<var_ntp_id>> for the NTP server address. You can enter multiple NTP IP addresses.

Note: If you plan to use vCenter Server high availability (HA), make sure that SSH access is enabled.

18. Configure the SSO domain name, password, and site name. Click Next.

Note: Record these values for your reference, especially if you deviate from the vsphere.local domain name.

19. Join the VMware Customer Experience Program if desired. Click Next.

20. View the summary of your settings. Click Finish or use the back button to edit settings.

21. A message appears stating that you will not be able to pause or stop the installation from completing after it has started. Click OK to continue.

The appliance setup continues. This takes several minutes.

A message appears indicating that the setup was successful.

Note: The links that the installer provides to access vCenter Server are clickable.

5.7 Configure VMware vCenter Server 6.7 and vSphere Clustering

To configure VMware vCenter Server 6.7 and vSphere clustering, complete the following steps:

1. Navigate to https://<<FQDN or IP of vCenter>>/vsphere-client/.

2. Click Launch vSphere Client.

3. Log in with the user name [email protected] and the SSO password you entered during the VCSA setup process.

Page 63: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

63 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

4. Right-click the vCenter name and select New Datacenter.

5. Enter a name for the data center and click OK.

Create vSphere Cluster.

Complete the following steps to create a vSphere cluster:

1. Right-click the newly created data center and select New Cluster.

2. Enter a name for the cluster.

3. Enable DR and vSphere HA by selecting the checkboxes.

4. Click OK.

Page 64: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

64 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Add ESXi Hosts to Cluster

1. Right-click the cluster and select Add Host.

2. To add an ESXi host to the cluster, complete the following steps:

a. Enter the IP or FQDN of the host. Click Next.

b. Enter the root user name and password. Click Next.

c. Click Yes to replace the host’s certificate with a certificate signed by the VMware certificate server.

d. Click Next on the Host Summary page.

e. Click the green + icon to add a license to the vSphere host.

Note: This step can be completed later if desired.

f. Click Next to leave lockdown mode disabled.

g. Click Next at the VM location page.

h. Review the Ready to Complete page. Use the back button to make any changes or select Finish.

3. Repeat steps 1 and 2 for Cisco UCS host B.

Note: This process must be completed for any additional hosts added to the FlexPod Express configuration.

Configure Coredump on ESXi Hosts

1. Using SSH, connect to the management IP ESXi host, enter root for the user name, and enter the root password.

2. Run the following commands:

esxcli system coredump network set -i ip_address_of_core_dump_collector -v vmk0 -o 6500

esxcli system coredump network set --enable=true

esxcli system coredump network check

3. The message Verified the configured netdump server is running appears after you

enter the final command.

Note: This process must be completed for any additional hosts added to FlexPod Express.

Conclusion

FlexPod Express provides a simple and effective solution by providing a validated design that uses

industry-leading components. By scaling through the addition of additional components, FlexPod Express

Page 65: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

65 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

can be tailored for specific business needs. FlexPod Express was designed by keeping in mind small to

midsize businesses, ROBOs, and other businesses that require dedicated solutions.

Acknowledgments

The authors would like to acknowledge the following people for their support and contribution to this

design:

• Paul Onofrietti Onotracy

• Arvind Ramakrishnan

Where to Find Additional Information

To learn more about the information described in this document, refer to the following documents and/or

websites:

• NetApp Product Documentation http://docs.netapp.com

• FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 Design Guide https://www.netapp.com/us/media/nva-1125-design.pdf

Page 66: FlexPod Express with VMware vSphere 6.7 and AFF …3.1(3g) For Cisco UCS C220 M5 rack servers Cisco nenic driver 1.0.25.0 For VIC 1387 interface cards Cisco NX-OS nxos.7.0.3.I7.5.bin

66 FlexPod Express with VMware vSphere 6.7 and NetApp AFF A220 © 2019 NetApp, Inc. All Rights Reserved.

Refer to the Interoperability Matrix Tool (IMT) on the NetApp Support site to validate that the exact product and feature versions described in this document are supported for your specific environment. The NetApp IMT defines the product components and versions that can be used to construct configurations that are supported by NetApp. Specific results depend on each customer’s installation in accordance with published specifications.

Copyright Information

Copyright © 2019 NetApp, Inc. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means—graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner.

Software derived from copyrighted NetApp material is subject to the following license and disclaimer:

THIS SOFTWARE IS PROVIDED BY NETAPP “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp.

The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications.

Data contained herein pertains to a commercial item (as defined in FAR 2.101) and is proprietary to

NetApp, Inc. The U.S. Government has a non-exclusive, non-transferrable, non-sublicensable, worldwide,

limited irrevocable license to use the Data only in connection with and in support of the U.S. Government

contract under which the Data was delivered. Except as provided herein, the Data may not be used,

disclosed, reproduced, modified, performed, or displayed without the prior written approval of NetApp,

Inc. United States Government license rights for the Department of Defense are limited to those rights

identified in DFARS clause 252.227-7015(b).