+ All Categories
Home > Documents > Flight F60 T · ACMV - PCV/VCV/PRVC SIMV - PCV/VCV/PRVC SPONT (CPAP, BPAP) Volume Guarantee B-Lev...

Flight F60 T · ACMV - PCV/VCV/PRVC SIMV - PCV/VCV/PRVC SPONT (CPAP, BPAP) Volume Guarantee B-Lev...

Date post: 18-Jun-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
2
TRANSPORT CRITICAL CARE ACUTE NIV Hospital Long Term Care Emergency Home Care Greater Flexibility and Improved Outcome Flight 60T provides care givers the high degree of autonomy and ability to focus on what is most important for their patients with minimal equipment modifications ICU Quality Ventilation Anywhere Hospital - Acute Care, ER, Transport, Step Down EMS and Transport Emergency and Preparedness Home care CCV - Continuity of Care Ventilation Flight F60 T Critical Care and Acute Noninvasive Ventilation TURBINE Flight 60T is an acute care ventilator that offers Flexibility and Mobility, with uninterrupted Continue of Care Ventilation in every clinical setting Your Partner in Ventilation
Transcript
Page 1: Flight F60 T · ACMV - PCV/VCV/PRVC SIMV - PCV/VCV/PRVC SPONT (CPAP, BPAP) Volume Guarantee B-Lev (Bi-Phasic, APRV) CONTROLS NPPV OFF/LOW/HIGH (leak compensation up to 60 LPM) VG

TRANSPO

RT

CRIT

ICAL

CAR

E

ACUTE NIV

Hospital Long Term Care

EmergencyHome Care

Greater Flexibility andImproved OutcomeFlight 60T provides care givers the high degree of autonomy and ability to focus on what is most important for their patients with minimal equipment modifications

ICU Quality Ventilation AnywhereHospital

- Acute Care, ER, Transport, Step Down

EMS and Transport

Emergency and PreparednessHome care

CCV - Continuity of Care Ventilation

Flight F60 T Critical Care andAcute Noninvasive Ventilation

TURBINE

Flight 60T is an acute care ventilator that offers Flexibility and Mobility, with uninterrupted Continue of Care Ventilation in every clinical setting

Your Partner in Ventilation

Page 2: Flight F60 T · ACMV - PCV/VCV/PRVC SIMV - PCV/VCV/PRVC SPONT (CPAP, BPAP) Volume Guarantee B-Lev (Bi-Phasic, APRV) CONTROLS NPPV OFF/LOW/HIGH (leak compensation up to 60 LPM) VG

LI‏T-

0111

R‏ev

A‏01

U‏SA

2‏01

6

0483

Flight Medical Innovations Ltd.www.flight-medical.com

FLIGHT 60 Technical SpecificationsTurbine Configuration

ALARMS (automatic)Check Circuit (Circuit Disconnect), Low/Empty Battery, O2 Supply Failed, Check O2 Sensor, Target Volume not reached

MONITORED PARAMETERSWaveforms Pressure, Flow, VolumeLoops Pressure/Volume & Flow/Volume

Trends Rate, Peak Inspiratory Pressure & Vte (up to 72 hours)

Airway Pressure LED Gauge -10 to 120 cmH2OPeak Inspiratory Pressure 0 to 120 cmH2OBase Pressure 0 to 99 cmH2OMean Pressure 0 to 99 cmH2OExhaled Tidal Volume 0 to 10LExhaled Minute Volume 0 to 99LInhaled Tidal Volume 0 to 10LInhaled Minute Volume 0 to 99LActual Breath Rate 0 to 99 b/minPeak Inspiratory Flow 1 to 120 L/minRSBI 0 to 200 1/min*L FiO2 21% to 100%I:E Ratio 1:99 to 3:1Battery Level 100% to 0%, Low, EmptySPECIAL FUNCTIONSBuzzer Level LOW/HIGH

Keypad Buttons Keypad buttons with audible indicator

Power Save ON/OFF/NIGHT

LanguagesEnglish, French, German, Greek, Hungarian, Italian, Polish, Portu-guese, Russian, Spanish, Turkish

Quick Start 5 preset ventilation modesSIZE AND WEIGHTDimensions (WxLxH) 29 x 28 x 25 cm / 11.4” x 11.0”x 9.8”

Weight 5.5 Kg / 12 lbs6.0 Kg / 13.3 lbs (with integrated mixer)

OXYGEN

O2 Mixer (optional) Internal integral, electronically controlled

High Pressure 35 to 90 psi Low Flow Port 0 to 15 L/min Low Flow Blending Bag 0 to 15 L/min POWER SUPPLYAC Power Inlet 100 to 240 VAC, 50-60HzDC Power Inlet 12 to 15 VDCInternal Batteries Hot Swappable 8 hours operationCharging Time Up to 3 hoursCOMMUNICATIONSUSB x2 Download Logs, SW UpgradeRS232 x2 Remote Alarm and MonitoringENVIRONMENTALOperation Temperature -18OC to 50OC / -0.4OF to 122OFStorage Temperature -20OC to 71OC / -4.0OF to 160OFRelative Humidity 15% to 95% at 31OC / 88OFOperation Altitude 110 kPa to 70 kPaWater/Dust Resistance IP34 (splash proof)STANDARDS

IEC 60601-1 ,IEC 60601-1-2 ,IEC 60601-2-12, ASTM 1246F ,ISO 10651-2/3, RTCA DO-160 F

MODES ACMV - PCV/VCV/PRVCSIMV - PCV/VCV/PRVCSPONT (CPAP, BPAP)Volume GuaranteeB-Lev (Bi-Phasic, APRV)

CONTROLS

NPPV OFF/LOW/HIGH(leak compensation up to 60 LPM)

VG Mode VtG (Tidal Volume Guarantee) MVG (Minute Volume Guarantee)

SIGH ON/OFF2min 100% O2 Function ON/OFFTidal Volume 30 to 2,200 mlBreath Rate 1 to 99 b/minInspiration Time (Ti) 0.1 to 3.0 secFlow 2 to 220 L/minPressure Control 5 to 80 cmH2OPressure Support (PSV) 0 to 60 cmH2OPEEP/CPAP 0 to 40 cmH2OPressure Trigger -20.0 to -0.1 cmH2OFlow Trigger 1 to 20 LPMRise Profile 5 levelsPSV Ti 0.1 to 3 secPSV Flow Termination 10% to 90%Volume Control Time/FlowFlow Waveform Square/DescendingFiO2 21% to 100%FiO2 Sensor ON, OFF, CalibrateManual Breath 0 to 3 secPanel Lock ON/OFFTrends ON/OFF/ClearVG Mode ControlsTarget VtG 30 to 2,200 mlPSV min 0 to 60 cmH2OPSV max 5 to 60 cmH2OTrigger Delay ON/OFFB-Lev ControlsP High 3 to 60 cmH2OP Low 0 to 30 cmH2OT High (Ti) 1 to 15 secT Low 0.5 to 5 secInverse I:E 30:1ALARMS (variable)Alarm Prioritization 3 Levels – Caution, Medium, HighLow Minute Volume 0.0 to 50 L/minLow Pressure OFF, 1 to 98 cmH2OHigh Pressure 4 to 99 cmH2OHigh Minute Volume 0.1 to 50 L/minHigh FiO2 31% to 99%, OFFLow FiO2 OFF, 22% to 90% High Rate OFF, 1 to 99 bpmLow Rate OFF, 1 to 99 bpmLow Vte OFF, 10 to 2,200mlLow Vti OFF, 10 to 2,200mlApnea/Back-Up Ventilation 10-60 sec