Effective June 2009 www.ascsteeldeck.com 1 ASC Steel Deck Table of Contents Floor Deck B-36 Composite....................................................................... 2 N-24 Composite ..................................................................... 8 2W-36 Composite ................................................................ 14 2WF-36 Composite .............................................................. 25 3W-36 Composite ................................................................ 30 3WF-36 Composite .............................................................. 40 ASC2 & ASC3 Composite .................................................... 45 Concrete Deck Form CF 7/8” ................................................................................. 51 CF 1 3/8” .............................................................................. 52 Deep Deck 4 1/2” Deep Deck ................................................................ 53 6” Deep Deck ...................................................................... 53 7 1/2” Deep Deck ................................................................ 54 Technical/Specifications General Notes ...................................................................... 55 Fire Resistance Ratings ......................................................... 56 Shear Stud Data .................................................................... 57 Concrete Weights and Volumes ........................................... 58 Code Approvals .................................................................... 58 General Comments on Extraordinary Conditions ................ 59 SDI Edge Form ..................................................................... 60 Floor Deck Accessories and Standard Details ..................... 61 Composite Floor Deck Specifications .................................. 62 Materials and Finishes ........................................................... 64 Metric Conversion Chart ...................................................... 64 It is our objective to provide the highest quality products and services in the steel deck industry. This objective is partially accomplished through conducting extensive testing programs with independent testing facilities to ensure that our products comply with the stringent criteria of today’s building codes. Our steel deck products have been evaluated by the International Conference of Building Officials (ICC Evaluation Services Report No. 1414), listed by Underwriters Laboratories, Certified by the Steel Deck Institute and approved by Factory Mutual and City of Los Angeles. Additionally, our manufacturing plants are strategically located in the western United States so that we may provide the best possible service. Most importantly, our Sales Representatives, Customer Service and Engineering Services Departments are prepared to assist you with the specific requirements of your project. How To Use This Catalog This Catalog contains information about Floor Deck, Concrete Form and Deep Deck profiles. Included with the profiles are reaction tables, section properties, design load tables and diagrams of the profiles. The Technical/Specification section contains further information applicable to all profiles. Step 1: Select the type of application (Floor Deck, Form or Deep Deck). Step 2: Identify which profile is appropriate for your specific design and select the corresponding page number. Step 3: Contact ASC Steel Deck 1-800-726-2727.
Transcript
Page 1: Floor Deck

Effective June 2009 www.ascsteeldeck.com 1

ASC Steel Deck

Table of Contents

Floor Deck

B-36 Composite .......................................................................2

N-24 Composite .....................................................................8

2W-36 Composite ................................................................14

2WF-36 Composite ..............................................................25

3W-36 Composite ................................................................30

3WF-36 Composite ..............................................................40

ASC2 & ASC3 Composite ....................................................45

Concrete Deck Form

CF 7/8” .................................................................................51

CF 1 3/8” ..............................................................................52

Deep Deck

4 1/2” Deep Deck ................................................................53

6” Deep Deck ......................................................................53

7 1/2” Deep Deck ................................................................54

Technical/Specifications

General Notes ......................................................................55

Fire Resistance Ratings .........................................................56

Shear Stud Data ....................................................................57

Concrete Weights and Volumes ...........................................58

Code Approvals ....................................................................58

General Comments on Extraordinary Conditions ................59

SDI Edge Form .....................................................................60

Floor Deck Accessories and Standard Details .....................61

Composite Floor Deck Specifications ..................................62

Materials and Finishes ...........................................................64

Metric Conversion Chart ......................................................64

It is our objective to provide the highest quality products and services in the steel deck industry. This objective is partially accomplished through conducting extensive testing programs with independent testing facilities to ensure that our products comply with the stringent criteria of today’s building codes. Our steel deck products have been evaluated by the International Conference of Building Officials (ICC Evaluation Services Report No. 1414), listed by Underwriters Laboratories, Certified by the Steel Deck Institute and approved by Factory Mutual and City of Los Angeles. Additionally, our manufacturing plants are strategically located in the western United States so that we may provide the best possible service. Most importantly, our Sales Representatives, Customer Service and Engineering Services Departments are prepared to assist you with the specific requirements of your project.

How To Use This CatalogThis Catalog contains information about Floor Deck, Concrete Form and Deep Deck profiles. Included with the profiles are reaction tables, section properties, design load tables and diagrams of the profiles. The Technical/Specification section contains further information applicable to all profiles.

Step 1: Select the type of application (Floor Deck, Form or Deep Deck).Step 2: Identify which profile is appropriate for your specific design and select the corresponding page number.Step 3: Contact ASC Steel Deck 1-800-726-2727.

Page 2: Floor Deck

2 Preformed Metal Floor Deck

ASC Steel Deck

B-36 Composite Floor Deck

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 3 1/2” Slab Weight: 23.0 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 230 184 163 145 130 117 105 96 87 80 70 61 542 230 204 183 165 130 117 105 96 87 80 70 61 54

22 3 230 204 183 145 130 117 105 96 87 80 70 61 54q4 1501 1462 1429 1401 1376 1354 1334 1317 1301 1287 1274 1262 1251q7 1710 1656 1609 1569 1533 1502 1474 1449 1427 1407 1388 1372 13561 301 267 239 196 176 159 138 117 100 87 75 66 582 301 267 239 216 196 179 138 117 100 87 75 66 58

20 3 301 267 239 216 196 179 138 117 100 87 75 66 58q4 1568 1522 1483 1448 1419 1392 1369 1348 1329 1312 1296 1282 1269q7 1820 1754 1698 1650 1607 1570 1537 1507 1480 1456 1434 1413 13951 301 267 239 215 196 179 143 131 114 99 86 75 662 301 267 239 215 196 179 164 151 140 99 86 75 66

18 3 301 267 239 215 196 179 164 151 140 130 86 75 66q4 1721 1660 1607 1562 1522 1487 1456 1428 1403 1380 1359 1340 1323q7 2056 1969 1895 1830 1774 1724 1679 1639 1604 1571 1542 1515 14911 300 266 238 215 195 178 163 151 140 109 95 83 732 300 266 238 215 195 178 163 151 140 130 121 83 73

16 3 300 266 238 215 195 178 163 151 140 130 121 113 106q4 1890 1813 1748 1691 1641 1597 1558 1523 1492 1463 1437 1414 1392q7 2309 2201 2107 2026 1955 1893 1838 1788 1743 1703 1666 1632 1602

2-3/8” 3-5/8”

1-1/2”

1-3/4”

36”

6”

FD_1 B-364 Welds 7 Welds

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

B-36 Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

22 1.68 0.178 0.180 0.19520 2.04 0.220 0.235 0.24618 2.70 0.302 0.321 0.33616 3.36 0.379 0.407 0.415

1. Section Properties are based on minimum 38 ksi steel (Fy)

Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

22416 468 520 572 625 677 7291007 1103 1213 1363 1513 1663 1813

20700 776 853 929 1005 1082 11581495 1617 1739 1897 2088 2280 2472

181443 1568 1693 1818 1943 2068 21932734 2909 3084 3258 3436 3710 3985

162434 2608 2782 2957 3131 3305 34804350 4578 4806 5034 5262 5490 5786

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

Page 3: Floor Deck

Effective June 2009 www.ascsteeldeck.com 3

ASC Steel Deck

B-36 Composite Floor DeckB-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4” 1 Hour Fire Rating Slab Weight: 27.5 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 245 214 189 168 151 136 122 111 101 92 84 77 712 268 238 213 168 151 136 122 111 101 92 84 77 71

22 3 268 238 213 168 151 136 122 111 101 92 84 77 71q4 1659 1620 1587 1559 1534 1512 1492 1475 1459 1445 1432 1420 1409q7 1868 1814 1767 1727 1691 1660 1632 1607 1585 1565 1546 1530 15141 350 311 254 227 204 184 167 152 139 128 1147 108 1002 350 311 278 251 228 208 167 152 139 128 117 108 100

20 3 350 311 278 251 228 208 167 152 139 128 117 108 100q4 1726 1680 1641 1606 1577 1550 1527 1506 1487 1470 1454 1440 1427q7 1978 1912 1856 1808 1765 1728 1695 1665 1638 1614 1591 1571 15531 349 309 277 250 227 183 166 151 138 126 116 107 992 349 309 277 250 227 207 190 175 138 126 116 107 99

18 3 349 309 277 250 227 207 190 175 162 126 116 107 99q4 1879 1818 1765 1720 1680 1645 1614 1586 1561 1538 1517 1498 1481q7 2214 2127 2053 1988 1931 1882 1837 1797 1762 1729 1700 1673 16491 347 307 275 248 225 206 189 174 136 125 115 106 982 347 307 275 248 225 206 189 174 161 150 115 106 98

16 3 347 307 275 248 225 206 189 174 161 150 140 131 98q4 2048 1971 1906 1849 1799 1755 1716 1681 1650 1621 1595 1572 1550q7 2467 2359 2265 2184 2113 2051 1995 1946 1901 1861 1824 1790 1760

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4 3/4” 2 Hour Fire Rating Slab Weight: 34.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 299 262 231 206 184 165 149 136 123 113 103 64 872 328 291 231 206 184 165 149 136 123 113 103 94 87

22 3 328 291 231 206 184 165 149 136 123 113 103 94 87q4 1895 1857 1824 1796 1771 1749 1729 1712 1696 1682 1669 1657 1646q7 2105 2051 2004 1964 1928 1897 1869 1844 1822 1802 1783 1767 17511 428 380 311 277 249 225 204 186 170 156 143 132 1222 428 380 340 306 278 225 204 186 170 156 143 132 122

20 3 428 380 340 306 278 225 204 186 170 156 143 132 122q4 1963 1917 1878 1843 1813 1787 1764 1743 1724 1707 1691 1677 1664q7 2215 2149 2093 2045 2002 1965 1931 1902 1875 1851 1828 1808 17901 425 377 337 304 246 222 202 184 168 154 141 130 1202 425 377 337 304 276 252 231 184 168 154 141 130 120

18 3 425 377 337 304 276 252 231 213 168 154 141 130 120q4 2116 2055 2002 1957 1917 1882 1851 1823 1798 1775 1754 1735 1718q7 2451 2364 2290 2225 2168 2119 2074 2034 1999 1966 1937 1910 18861 421 374 334 301 274 250 229 181 166 152 139 128 1192 421 374 334 301 274 250 229 211 196 152 139 128 119

16 3 421 374 334 301 274 250 229 211 196 182 170 128 119q4 2285 2208 2143 2086 2036 1992 1953 1918 1886 1858 1832 1808 1787q7 2704 2595 2502 2421 2350 2288 2232 2183 2138 2098 2061 2027 1996

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

Page 4: Floor Deck

4 Preformed Metal Floor Deck

ASC Steel Deck

B-36 Composite Floor DeckB-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 11/16” 3 Hour Fire Rating Slab Weight: 42.1 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 370 324 286 254 227 205 185 168 152 139 127 117 1072 405 359 286 254 227 205 185 168 152 139 127 117 107

22 3 405 324 286 254 227 205 185 168 152 139 127 117 107q4 2192 2153 2121 2092 2067 2045 2026 2008 1992 1978 1965 1953 1943q7 2401 2347 2300 2260 2224 2193 2165 2141 2118 2098 2080 2063 20471 529 433 384 343 308 278 252 230 210 192 177 163 1512 529 469 420 343 308 278 252 230 210 192 177 163 151

20 3 329 469 420 378 308 278 252 230 210 192 177 163 151q4 2259 2213 2174 2140 2110 2083 2060 2039 2020 2003 1987 1973 1960q7 2511 2446 2390 2341 2298 2261 2228 2198 2171 2147 2125 2104 20861 525 465 416 339 304 275 249 227 207 190 175 161 1492 525 465 416 375 341 311 249 227 207 190 175 161 149

18 3 525 465 416 375 341 311 286 227 207 190 175 161 149q4 2412 2351 2299 2253 2213 2178 2147 2119 2094 2071 2050 2031 2014q7 2748 2661 2586 2521 2465 2415 2370 2331 2295 2263 2233 2206 21821 519 461 412 372 337 308 246 224 204 187 172 159 1462 519 461 412 372 337 308 283 261 204 187 172 159 146

16 3 519 461 412 372 337 308 283 261 241 224 172 159 146q4 2581 2505 2439 2382 2332 2288 2249 2214 2183 2154 2128 2105 2083q7 3001 2892 2798 2717 2647 2584 2529 2479 2434 2394 2357 2323 2293

B-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 3 1/2” Slab Weight: 30.3 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 205 179 157 139 124 111 100 90 81 74 67 61 552 230 204 183 139 124 111 100 90 81 74 67 61 55

22 3 230 204 157 139 124 111 100 90 81 74 67 61 55q4 1825 1787 1754 1725 1700 1678 1659 1641 1626 1611 1599 1587 1576q7 2035 1980 1934 1893 1858 1826 1799 1774 1751 1731 1713 1696 16811 301 267 213 190 170 153 138 125 114 104 95 83 732 301 267 239 216 196 153 138 125 114 104 95 83 73

20 3 301 267 239 216 196 153 138 125 114 104 95 83 73q4 1893 1847 1807 1773 1743 1717 1693 1672 1653 1636 1621 1606 1593q7 2144 2079 2023 1974 1932 1894 1861 1831 1804 1780 1758 1738 17191 301 267 239 215 196 152 137 125 113 104 95 87 802 301 267 239 215 196 179 164 151 113 104 95 87 80

18 3 301 267 239 215 196 179 164 151 140 104 95 87 80q4 2046 1984 1932 1886 1847 1811 1780 1752 1727 1704 1684 1665 1647q7 2381 2294 2219 2155 2098 2048 2004 1964 1928 1896 1866 1840 18151 300 266 238 215 195 178 163 124 113 103 94 86 792 300 266 238 215 195 178 163 151 140 130 94 86 79

16 3 300 266 238 215 195 178 163 151 140 130 121 113 79q4 2215 2138 2072 2015 1965 1921 1882 1847 1816 1787 1762 1738 1716q7 2634 2525 2432 2351 2280 2217 2162 2112 2068 2027 1990 1957 1926

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

Page 5: Floor Deck

Effective June 2009 www.ascsteeldeck.com 5

ASC Steel Deck

B-36 Composite Floor DeckB-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 4” Slab Weight: 36.3 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 238 207 182 161 144 128 115 104 94 85 77 70 642 268 238 182 161 144 128 115 104 94 85 77 70 64

22 3 268 238 182 161 144 128 115 104 94 85 77 70 64q4 2064 2026 1993 1964 1940 1918 1898 1881 1865 1851 1838 1826 1815q7 2274 2219 2173 2132 2097 2066 2038 2013 1991 1970 1952 1935 19201 350 280 247 220 197 177 160 145 132 121 110 101 932 350 311 278 251 197 177 160 145 132 121 110 101 93

20 3 350 311 278 251 197 177 160 145 132 121 110 101 93q4 2132 2086 2046 2012 1982 1956 1932 1911 1892 1875 1860 1846 1833q7 2383 2318 2262 2213 2171 2133 2100 2070 2043 2019 1997 1977 19581 349 309 277 250 195 176 159 144 131 119 109 100 922 349 309 277 250 227 207 190 144 131 119 109 100 92

18 3 349 309 277 250 227 207 190 175 131 119 109 100 92q4 2285 2223 2171 2125 2086 2050 2019 1991 1966 1943 1923 1904 1887q7 2620 2533 2458 2394 2337 2287 2243 2203 2167 2135 2106 2079 20541 347 307 275 248 225 206 157 142 129 118 108 99 912 347 307 275 248 225 206 189 174 161 118 108 99 91

16 3 347 307 275 248 225 206 189 174 161 150 108 99 91q4 2454 2377 2311 2254 2205 2161 2121 2087 2055 2027 2001 1977 1955q7 2873 2764 2671 2590 2519 2457 2401 2351 2307 2266 2229 2196 2165

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5” 1 Hour Fire Rating Slab Weight: 48.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 308 269 236 209 186 166 149 135 122 110 100 91 822 348 269 236 209 186 166 149 135 122 110 100 91 82

22 3 348 269 236 209 186 166 149 135 122 110 100 91 82q4 2542 2504 2471 2443 2418 2396 2376 2359 2343 2329 2316 2304 2293q7 2752 2697 2651 2610 2575 2544 2516 2491 2469 2449 2430 2413 23981 414 363 321 285 255 229 207 188 171 156 143 131 1202 455 403 361 285 255 229 207 188 171 156 143 131 120

20 3 455 403 361 285 255 229 207 188 171 156 143 131 120q4 2610 2564 2524 2490 2460 2434 2410 2389 2371 2353 2338 2324 2311q7 2862 2796 2740 2692 2649 2612 2578 2548 2522 2497 2475 2455 24371 451 400 358 282 252 227 205 186 169 154 141 129 1182 451 400 358 323 293 227 205 186 169 154 141 129 118

18 3 451 400 358 323 293 268 205 186 169 154 141 129 118q4 2763 2702 2649 2604 2564 2529 2497 2469 2444 2422 2401 2382 2365q7 3098 3011 2936 2872 2815 2765 2721 2681 2645 2613 2584 2557 25321 447 396 355 320 290 224 202 183 166 152 139 127 1162 447 396 355 320 290 265 243 183 166 152 139 127 116

16 3 447 396 355 320 290 265 243 224 208 152 139 127 116q4 2932 2855 2789 2733 2683 2639 2600 2565 2533 2505 2479 2455 2434q7 3351 3242 3149 3068 2997 2935 2879 2830 2785 2744 2708 2674 2643

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

Page 6: Floor Deck

6 Preformed Metal Floor Deck

ASC Steel Deck

B-36 Composite Floor DeckB-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5 1/2” 1 1/2 Hour Fire Rating Slab Weight: 54.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 345 301 264 234 208 186 167 151 136 123 112 101 922 389 301 264 234 208 186 167 151 136 123 112 101 92

22 3 345 301 264 234 208 186 167 151 136 123 112 101 92q4 2781 2743 2710 2682 2657 2635 2615 2598 2582 2568 2555 2543 2532q7 2991 2937 2890 2849 2814 2783 2755 2730 2708 2688 2669 2652 26371 464 406 359 319 285 257 232 210 191 174 159 146 1342 509 451 359 319 285 257 232 210 191 174 159 146 134

20 3 509 451 404 319 285 257 232 210 191 174 159 146 134q4 2849 2803 2763 2729 2699 2673 2649 2628 2610 2593 2577 2563 2550q7 3101 3035 2979 2931 2888 2851 2817 2787 2761 2736 2714 2694 26761 504 447 355 315 282 254 229 208 189 172 157 144 1322 504 447 400 361 328 254 229 208 189 172 157 144 132

18 3 504 447 400 361 328 254 229 208 189 172 157 144 132q4 3002 2941 2888 2843 2803 2768 2737 2709 2683 2661 2640 2621 2604q7 3337 3250 3176 3111 3054 3004 2760 2920 2885 2852 2823 2796 27711 500 443 396 357 278 250 226 205 186 169 155 142 1302 500 443 396 357 324 296 226 205 186 169 155 142 130

16 3 500 443 396 357 324 296 272 251 186 169 155 142 130q4 3171 3094 3029 2972 2922 2878 2839 2804 2772 2744 2718 2694 2673q7 3590 3481 3388 3307 3236 3174 3118 3069 3024 2983 2947 2913 2882

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6” 2 Hour Fire Rating Slab Weight: 60.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 382 333 293 259 231 206 185 167 151 136 124 112 1002 382 333 293 259 231 206 185 167 151 136 124 112 100

22 3 382 333 293 259 231 206 185 167 151 136 124 112 100q4 3020 2982 2949 2921 2896 2874 2854 2837 2821 2807 2794 2782 2771q7 3230 3176 3129 3088 3053 3022 2994 2969 2947 2927 2908 2892 28761 513 450 397 353 316 284 257 233 212 193 177 162 1492 563 499 397 353 316 284 257 233 212 193 177 162 149

20 3 563 499 397 353 316 284 257 233 212 193 177 162 149q4 3088 3042 3002 2968 2928 2912 2889 2868 2849 2832 2816 2802 2789q7 3340 3274 3218 3170 3127 3090 3056 3027 3000 2975 2953 2933 29151 559 495 393 349 312 281 254 230 209 191 174 160 1472 559 495 443 400 312 281 254 230 209 191 174 160 147

18 3 559 495 443 400 363 281 254 230 209 191 174 160 147q4 3241 3180 3127 3082 3042 3007 2976 2948 2923 2900 2879 2860 2843q7 3576 3489 3415 3350 3293 3243 3199 3159 3124 3091 3062 3035 30101 553 490 439 396 308 277 250 227 206 188 172 157 1442 553 490 439 396 359 328 250 227 206 188 172 157 144

16 3 553 490 439 396 359 328 301 227 206 188 172 157 144q4 3410 3333 3268 3211 3161 3117 3078 3043 3011 2983 2957 2933 2912q7 3829 3720 3627 3546 3475 3413 3357 3308 3263 3223 3186 3152 3121

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

Page 7: Floor Deck

Effective June 2009 www.ascsteeldeck.com 7

ASC Steel Deck

B-36 Composite Floor DeckB-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6 3/4” 3 Hour Fire Rating Slab Weight: 69.5 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 438 382 336 297 265 237 213 191 173 157 142 127 1122 438 382 336 297 265 237 213 191 173 157 142 127 112

22 3 438 382 336 297 265 237 213 191 173 157 142 127 112q4 3379 3341 3308 3279 3254 3232 3213 3195 3180 3166 3153 3141 3130q7 3589 3534 3488 3447 3412 3380 3353 3328 3306 3285 3267 3280 32351 589 516 456 405 363 326 295 267 243 222 203 186 1712 646 516 456 405 363 326 295 267 243 222 203 186 171

20 3 646 516 456 405 363 326 295 267 243 222 203 186 171q4 3447 3401 3361 3327 3297 3271 3247 3226 3207 3190 3175 3160 3147q7 3698 3633 3577 3528 3486 3448 3415 3385 3358 3334 3312 3292 32731 641 511 451 401 359 322 291 264 240 219 200 184 1682 641 568 509 401 359 322 291 264 240 219 200 184 168

18 3 641 568 509 459 359 322 291 264 240 219 200 184 168q4 3600 3538 3486 3440 3401 3365 3334 3306 3281 3238 3258 3219 3201q7 3935 3848 3773 3709 3652 3602 3588 3518 3482 3450 3421 3394 33691 634 563 503 396 354 318 287 260 237 216 197 181 1662 634 563 503 454 412 318 287 260 237 216 197 181 166

16 3 634 563 503 454 412 376 287 260 237 216 197 181 166q4 3769 3692 3626 3569 3519 3476 3436 3401 3370 3342 3316 3292 3270q7 4188 4079 3986 3905 3834 3772 3716 3666 3622 3581 3544 3511 3480

1. In shaded areas, mid-span deck shoring required during construction.2. q4 and q7 “q”=allowable diaphragm shear (plf): “4”, “7”=number of welds to support.3. See pg. 55 for General Notes.

Page 8: Floor Deck

8 Preformed Metal Floor Deck

ASC Steel Deck

N-24 Composite Floor Deck

8

8”

3”

2” 6”

2-5/8” 5-3/8”

24”

FD_2 N-24

2 Welds 4 Welds

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 1/2” 1 Hour Fire Rating Slab Weight: 30.9 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 195 177 161 148 114 104 95 87 80 73 68 63 58 54 50 46 43 402 195 177 161 148 136 126 117 110 102 73 68 63 58 54 50 46 43 40

22 3 195 177 161 148 136 126 117 110 102 73 68 63 58 54 50 46 43 40q2 1284 1271 1261 1251 1242 1235 1228 1221 1215 1210 1205 1201 1196 1192 1189 1185 1182 1179q4 1398 1373 1352 1332 1315 1300 1286 1273 1261 1251 1241 1232 1223 1216 1208 1201 1195 11891 257 233 213 195 180 167 155 144 112 104 96 89 83 78 72 68 63 592 257 233 213 195 180 167 155 144 135 127 119 89 83 78 72 68 63 59

20 3 257 233 213 195 180 167 155 144 135 127 119 112 103 78 72 68 63 59q2 1283 1268 1256 1244 1234 1224 1216 1208 1201 1195 1189 1184 1178 1174 1169 1165 1162 1158q4 1444 1415 1389 1366 1345 1326 1309 1294 1280 1267 1255 1245 1234 1225 1216 1208 1201 11941 260 236 215 197 182 169 157 146 137 128 121 114 107 78 73 68 64 602 260 236 215 197 182 169 157 146 137 128 121 144 107 102 97 68 64 60

18 3 260 236 215 197 182 169 157 146 137 128 121 114 107 102 97 91 83 76q2 1306 1287 1269 1254 1240 1228 1216 1206 1197 1188 1180 1173 1166 1160 1154 1149 1144 1139q4 1555 1516 1481 1450 1423 1398 1376 1355 1337 1320 1304 1289 1276 1263 1252 1241 1231 12211 262 238 217 199 184 170 158 147 138 129 122 115 108 103 97 68 64 602 262 238 217 199 184 170 158 147 138 129 122 115 108 103 97 93 88 84

16 3 262 238 217 199 184 170 158 147 138 129 122 115 108 103 97 93 88 84q2 1347 1322 1301 1281 1264 1249 1235 1222 1210 1199 1190 1181 1172 1164 1157 1150 1144 1138q4 1682 1632 1589 1551 1516 1485 1457 1431 1408 1387 1367 1349 1332 1317 1302 1289 1276 1264

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

N-24 Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

22 2.18 0.771 0.361 0.44920 2.58 0.945 0.467 0.55418 3.40 1.330 0.689 0.76516 4.22 1.716 0.882 0.949

1. Section properties are based on minimum 38 ksi steel (Fy)

N-24 Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

22292 328 365 402 438 475 512728 797 876 985 1093 1202 1310

20501 556 610 665 720 774 8291095 1184 1274 1389 1530 1670 1811

181057 1148 1240 1331 1423 1514 16062035 2165 2296 2426 2557 2762 2966

161805 1935 2064 2193 2323 2452 25823269 3440 3611 3783 3954 4125 4348

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

Page 9: Floor Deck

Effective June 2009 www.ascsteeldeck.com 9

ASC Steel Deck

N-24 Composite Floor DeckN-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 1/2” 1 Hour Fire Rating Slab Weight: 30.9 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 213 193 176 136 123 112 102 93 86 79 73 67 62 57 53 49 45 422 213 193 176 162 149 138 128 120 86 79 73 67 62 57 53 49 45 42

22 3 213 193 176 162 149 138 128 120 86 79 73 67 62 57 53 49 45 42q2 1442 1429 1419 1409 1400 1393 1386 1379 1373 1368 1363 1359 1354 1350 1347 1343 1340 1337q4 1556 1531 1510 1490 1473 1458 1444 1431 1419 1409 1399 1390 1381 1374 1366 1359 1353 13471 280 254 232 213 196 182 169 131 121 110 103 96 89 83 77 72 67 632 280 254 232 213 196 182 169 157 147 138 103 96 89 83 77 72 67 63

20 3 280 254 232 213 196 182 169 157 147 138 130 123 89 83 77 72 67 63q2 1441 1427 1414 1402 1392 1382 1374 1366 1359 1353 1347 1342 1336 1332 1327 1323 1320 1316q4 1602 1574 1547 1542 1503 1484 1467 1452 1438 1425 1413 1403 1392 1383 1374 1366 1359 13521 281 255 233 214 197 182 170 158 148 139 131 123 89 83 77 72 67 632 281 255 233 214 197 182 170 158 148 139 131 123 116 110 77 72 67 63

18 3 281 255 233 214 197 182 170 158 148 139 131 123 116 110 105 99 95 63q2 1464 1444 1427 1412 1398 1386 1374 1364 1355 1346 1338 1331 1324 1318 1312 1307 1302 1297q4 1713 1674 1639 1608 1581 1556 1534 1513 1495 1478 1462 1447 1434 1421 1410 1399 1389 13791 282 256 233 214 198 183 170 159 148 139 131 123 117 110 77 72 67 622 282 256 233 214 198 183 170 159 148 139 131 123 117 110 105 100 95 62

16 3 282 256 233 214 198 183 170 159 148 139 131 123 117 110 105 100 95 90q2 1505 1480 1459 1439 1422 1407 1393 1380 1368 1357 1348 1338 1330 1322 1315 1308 1302 1296q4 1840 1790 1747 1709 1674 1643 1615 1589 1566 1545 1525 1507 1490 1475 1460 1447 1434 1422

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 6 1/4” 2 Hour Fire Rating Slab Weight: 37.8 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 244 221 170 154 139 126 115 105 97 89 81 75 69 64 59 54 50 462 244 221 202 185 171 158 147 105 97 89 81 75 69 64 59 54 50 46

22 3 244 221 202 185 171 158 115 105 97 89 81 75 69 64 59 54 50 46q2 1679 1666 1656 1646 1637 1630 1623 1616 1610 1605 1600 1596 1591 1587 1584 1580 1577 1574q4 1793 1768 1747 1727 1710 1695 1681 1668 1656 1646 1636 1627 1618 1610 1603 1596 1590 15841 319 290 265 243 224 175 161 148 136 126 116 108 100 93 87 81 75 702 319 290 265 243 224 207 193 180 168 126 116 108 100 93 87 81 75 70

20 3 319 290 265 243 224 207 193 180 168 158 116 108 100 93 87 81 75 70q2 1678 1664 1651 1639 1629 1619 1611 1603 1596 1590 1584 1578 1573 1569 1564 1560 1557 1553q4 1839 1810 1784 1761 1740 1721 1704 1689 1675 1662 1650 1640 1629 1620 1611 1603 1596 15881 319 290 264 243 224 207 193 180 168 158 116 107 99 92 86 80 75 702 319 290 264 243 224 207 193 180 168 158 148 140 132 92 86 80 75 70

18 3 319 290 264 243 224 207 193 180 168 158 148 140 132 125 119 80 75 70q2 1701 1681 1664 1649 1635 1623 1611 1601 1592 1583 1575 1568 1561 1555 1549 1544 1539 1534q4 1950 1911 1876 1845 1818 1793 1771 1750 1732 1714 1699 1684 1671 1658 1647 1636 1626 16161 318 289 264 242 223 207 191 179 168 157 148 139 132 91 85 79 74 692 318 289 264 242 223 207 191 179 168 157 148 139 132 125 118 79 74 69

16 3 318 289 264 242 223 207 191 179 168 157 148 139 132 125 118 112 107 102q2 1742 1717 1696 1676 1659 1644 1629 1617 1605 1594 1585 1575 1567 1559 1552 1545 1539 1533q4 2077 2027 1984 1946 1911 1880 1852 1826 1803 1782 1762 1744 1727 1712 1697 1684 1671 1659

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

Page 10: Floor Deck

10 Preformed Metal Floor Deck

ASC Steel Deck

N-24 Composite Floor DeckN-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)TotAl Slab Thickness: 7 3/16” 3 Hour Fire Rating Slab Weight: 46.3 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 286 221 198 179 162 147 134 122 112 103 94 87 80 73 68 62 57 532 286 259 217 200 162 147 134 122 112 103 94 87 80 73 68 62 57 53

22 3 286 259 217 200 162 147 134 122 112 103 94 87 80 73 68 62 57 53q2 1975 1963 1952 1942 1934 1926 1919 1912 1907 1901 1896 1892 1888 1884 1880 1877 1873 1870q4 2089 2065 2043 2024 2006 1991 1977 1964 1952 1942 1932 1923 1914 1907 1899 1893 1886 18801 374 339 310 284 223 204 187 172 158 146 135 125 116 108 100 93 87 812 374 339 310 284 262 243 226 172 158 146 135 125 116 108 100 93 87 81

20 3 374 339 310 284 262 243 226 210 158 146 135 125 116 108 100 93 87 81q2 1975 1960 1947 1935 1925 1916 1907 1899 1892 1886 1880 1875 1870 1865 1861 1857 1853 1849q4 2135 2106 2080 2057 2036 2017 2001 1985 1971 1958 1947 1936 1926 1916 1908 1899 1892 18851 372 338 309 283 261 242 225 210 157 144 133 124 115 106 99 92 86 802 372 338 309 283 261 242 225 210 196 184 173 124 115 106 99 92 86 80

18 3 372 338 309 283 261 242 225 210 196 184 173 163 154 146 99 92 86 80q2 1997 1978 1960 1945 1931 1919 1908 1897 1888 1879 1872 1864 1858 1851 1846 1840 1835 1830q4 2246 2207 2172 2142 2114 2089 2067 2046 2028 2011 1995 1980 1967 1955 1943 1932 1922 19131 370 336 307 281 260 240 223 208 195 183 172 162 113 105 97 91 84 782 370 336 307 281 260 240 223 208 195 183 172 162 153 145 97 91 84 78

16 3 370 336 307 281 260 240 223 208 195 183 172 162 153 145 138 131 125 78q2 2038 2013 1992 1972 1955 1940 1926 1913 1901 1891 1881 1872 1863 1855 1848 1841 1835 1829q4 2373 2324 2280 2242 2207 2176 2148 2123 2099 2078 2058 2040 2023 2008 1993 1980 1967 1955

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight (145 pcf)Total Slab Thickness: 5” Slab Weight: 34.6 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 195 177 161 119 107 97 88 80 73 67 61 56 51 47 43 39 36 332 195 177 161 148 136 126 117 80 73 67 61 56 51 47 43 39 36 33

22 3 195 177 161 148 136 126 117 80 73 67 61 56 51 47 43 39 36 33q2 1608 1596 1585 1575 1567 1559 1552 1546 1540 1534 1530 1525 1521 1517 1513 1510 1507 1504q4 1722 1698 1676 1657 1640 1524 1610 1597 1586 1576 1565 1556 1548 1540 1533 1526 1520 15141 257 233 213 195 180 167 125 115 106 97 90 83 77 71 66 61 57 522 257 233 213 195 180 167 154 144 135 97 90 83 77 71 66 61 57 52

20 3 257 233 213 195 180 167 154 144 135 127 90 83 77 71 66 61 57 52q2 1608 1593 1580 1563 1558 1549 1540 1533 1526 1519 1513 1508 1503 1498 1494 1490 1486 1482q4 1769 1739 1713 1690 1669 1651 1635 1619 1605 1592 1580 1569 1559 1550 1541 1533 1525 15181 260 236 215 197 182 169 157 146 137 128 117 83 77 71 66 61 57 532 260 236 215 197 182 169 157 146 137 128 121 114 107 71 66 61 57 53

18 3 260 236 215 197 182 169 157 146 137 128 121 114 107 102 97 88 57 53q2 1631 1611 1594 1578 1564 1552 1541 1531 1521 1513 1505 1498 1491 1485 1479 1473 1468 1464q4 1880 1840 1806 1775 1747 1723 1700 1680 1661 1644 1628 1614 1600 1588 1576 1565 1555 15461 262 238 217 199 184 170 158 147 138 129 122 115 108 72 66 61 57 532 262 238 217 199 184 170 158 147 138 129 122 115 108 103 97 93 57 53

16 3 262 238 217 199 184 170 158 147 138 129 122 115 108 103 97 93 88 84q2 1671 1647 1625 1606 1589 1573 1559 1546 1535 1524 1514 1505 1497 1488 1481 1475 1468 1462q4 2006 1957 1914 1875 1841 1810 1781 1756 1733 1711 1692 1673 1657 1641 1627 1613 1600 1588

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

Page 11: Floor Deck

Effective June 2009 www.ascsteeldeck.com 11

ASC Steel Deck

N-24 Composite Floor DeckN-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5 1/2” Slab Weight: 40.7 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 213 193 142 128 115 104 94 86 78 71 65 59 54 49 45 41 37 342 213 193 176 162 149 138 94 86 78 71 65 59 54 49 45 41 37 34

22 3 213 193 176 162 149 138 94 86 78 71 65 59 54 49 45 41 37 34q2 1847 1835 1824 1815 1806 1798 1791 1785 1779 1774 1769 1764 1760 1756 1752 1749 1746 1743q4 1962 1937 1915 1896 1879 1863 1849 1836 1825 1814 1804 1795 1787 1779 1772 1765 1759 17531 280 254 232 213 196 147 134 123 113 104 95 88 81 75 69 64 59 552 280 254 232 213 196 182 169 157 113 104 95 88 81 75 69 64 59 55

20 3 280 254 232 213 196 182 169 157 147 104 95 88 81 75 69 64 59 55q2 1847 1832 1819 1808 1797 1788 1779 1772 1765 1758 1752 1747 1742 1737 1733 1729 1725 1722q4 2008 1978 1952 1929 1908 1890 1873 1858 1844 1831 1819 1808 1798 1789 1780 1772 1764 17541 281 255 233 214 197 182 170 158 148 104 95 88 81 75 69 64 59 552 281 255 233 214 197 182 170 158 148 139 131 123 81 75 69 64 59 55

18 3 281 255 233 214 197 182 170 158 148 139 131 123 116 110 105 64 59 55q2 1870 1850 1833 1817 1804 1791 1780 1770 1760 1757 1744 1737 1730 1724 1718 1713 1707 1703q4 2119 2079 2045 2014 1986 1962 1939 1919 1900 1883 1867 1853 1839 1827 1815 1805 1794 17851 282 256 233 214 198 183 170 159 148 139 131 123 81 75 69 64 59 542 282 256 233 214 198 183 170 159 148 139 131 123 117 110 105 64 59 54

16 3 282 256 233 214 198 183 170 159 148 139 131 123 117 110 105 100 95 54q2 1910 1886 1864 1845 1828 1812 1798 1785 1774 1763 1753 1744 1736 1728 1721 1714 1707 1702q4 2245 2196 2153 2114 2080 2049 2021 1995 1972 1950 1931 1913 1896 1880 1866 1852 1839 1828

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6 1/2” 1 Hour Fire Rating Slab Weight: 52.7 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 254 187 167 150 135 122 110 100 90 82 74 68 62 56 51 46 42 372 254 231 211 194 135 122 110 100 90 82 74 68 62 56 51 46 42 37

22 3 254 231 211 194 135 122 110 100 90 82 74 68 62 56 51 46 42 37q2 2325 2313 2302 2293 2284 2276 2269 2263 2257 2252 2247 2242 2238 2234 2231 2227 2224 2221q4 2440 2415 2393 2374 2357 2341 2327 2315 2303 2292 2282 2273 2265 2257 2250 2243 2237 22311 333 303 276 210 190 173 157 144 132 121 111 102 94 87 80 74 68 632 333 303 276 254 234 217 157 144 132 121 111 102 94 87 80 74 68 63

20 3 333 303 276 254 234 217 201 144 132 121 111 102 94 87 80 74 68 63q2 2325 2310 2297 2286 2275 2266 2258 2250 2243 2237 2231 2225 2220 2215 2211 2207 2203 2200q4 2486 2456 2430 2407 2387 2368 2351 2336 2322 2309 2297 2286 2276 2267 2258 2250 2242 22351 333 302 276 253 233 216 201 143 131 120 110 101 93 86 79 73 67 622 333 302 276 253 233 216 201 187 175 164 110 101 93 86 79 73 67 62

18 3 333 302 276 253 233 216 201 187 175 164 155 146 93 86 79 73 67 62q2 2348 2328 2311 2295 2282 2269 2258 2248 2239 2230 2222 2215 2208 2202 2196 2191 2186 2181q4 2597 2558 2523 2492 2465 2440 2417 2397 2378 2361 2346 2331 2318 2305 2294 2283 2273 22631 331 301 275 252 233 215 200 187 175 164 106 100 92 85 78 72 66 612 331 301 275 252 233 215 200 187 175 164 154 145 92 85 78 72 66 61

16 3 331 301 275 252 233 215 200 187 175 164 154 145 137 130 123 72 66 61q2 2389 2364 2342 2323 2306 2290 2276 2263 2252 2241 2231 2222 2214 2206 2199 2192 2186 2180q4 2723 2674 2631 2592 2558 2527 2499 2473 2450 2429 2409 2391 2374 2358 2344 2330 2318 2306

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

Page 12: Floor Deck

12 Preformed Metal Floor Deck

ASC Steel Deck

N-24 Composite Floor DeckN-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 7” 1 1/2 Hour Fire Rating Slab Weight: 58.8 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 229 203 181 162 146 131 119 107 97 88 80 73 66 60 54 49 44 402 277 251 230 211 146 131 119 107 97 88 80 73 66 60 54 49 44 40

22 3 277 251 230 211 146 131 119 107 97 88 80 73 66 60 54 49 44 40q2 2565 2552 2541 2532 2523 2515 2508 2502 2496 2491 2486 2481 2477 2473 2470 2466 2463 2460q4 2679 2654 2633 2613 2596 2581 2566 2554 2542 2531 2522 2513 2504 2496 2489 2482 2476 24701 363 329 252 227 206 187 170 155 142 130 120 110 101 93 86 79 73 672 363 329 301 276 254 236 170 155 142 130 120 110 101 93 86 79 73 67

20 3 363 329 301 276 254 236 219 155 142 130 120 110 101 93 86 79 73 67q2 2564 2549 2536 2525 2514 2505 2497 2489 2482 2476 2470 2464 2459 2455 2450 2446 2442 2439q4 2725 2695 2669 2646 2626 2607 2590 2575 2561 2548 2536 2525 2515 2506 2497 2489 2481 24741 361 328 299 275 253 235 218 154 141 129 118 109 100 92 85 78 72 662 361 328 299 275 253 235 218 203 190 129 118 109 100 92 85 78 72 66

18 3 361 328 299 275 253 235 218 203 190 179 168 109 100 92 85 78 72 66q2 2587 2567 2550 2535 2521 2508 2497 2487 2478 2469 2461 2454 2447 2441 2435 2430 2425 2420q4 2836 2797 2762 2731 2704 2679 2656 2636 2617 2600 2585 2570 2557 2544 2533 2522 2512 25021 359 326 298 273 252 233 217 202 189 127 117 107 99 91 83 77 71 652 359 326 298 273 252 233 217 202 189 178 167 107 99 91 83 77 71 65

16 3 359 326 298 273 252 233 217 202 189 178 167 157 149 141 83 77 71 65q2 2628 2603 2581 2562 2545 2529 2515 2503 2491 2480 2470 2461 2453 2445 2438 2431 2425 2419q4 2962 2913 2870 2831 2797 2766 2738 2712 2689 2668 2648 2630 2613 2597 2583 2569 2557 2545

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 7 1/2” 2 Hour Fire Rating Slab Weight: 64.9 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 247 219 196 175 157 142 128 116 105 98 86 78 71 64 58 52 47 422 300 273 249 175 157 142 128 116 105 98 86 78 71 64 58 52 47 42

22 3 300 273 249 175 157 142 128 116 105 98 86 78 71 64 58 52 47 42q2 2804 2791 2781 2771 2762 2754 2747 2741 2735 2730 2725 2720 2716 2712 2709 2705 2702 2699q4 2918 2893 2872 2852 2835 2820 2806 2793 2781 2770 2761 2752 2743 2735 2728 2721 2715 27091 393 357 272 245 222 202 184 168 153 140 129 118 109 100 92 85 78 722 393 357 326 299 276 202 184 168 153 140 129 118 109 100 92 85 78 72

20 3 393 357 326 299 276 255 184 168 153 140 129 118 109 100 92 85 78 72q2 2803 2789 2775 2764 2754 2744 2736 2728 2721 2715 2709 2703 2698 2694 2689 2685 2681 2678q4 2964 2935 2909 2885 2865 2846 2829 2814 2800 2787 2775 2764 2754 2745 2736 2728 2721 27131 391 355 324 297 274 254 182 166 152 139 127 117 107 99 91 84 77 712 391 355 324 297 274 254 236 220 152 139 127 117 107 99 91 84 77 71

18 3 391 355 324 297 274 254 236 220 206 193 182 117 107 99 91 84 77 71q2 2826 2806 2789 2774 2760 2747 2736 2726 2717 2708 2700 2693 2686 2680 2674 2669 2664 2659q4 3075 3036 3001 2970 2943 2918 2896 2875 2856 2839 2824 2809 2796 2783 2772 2761 2751 27411 388 352 322 295 272 252 234 219 204 137 125 115 106 97 89 82 76 692 388 352 322 295 272 252 234 219 204 192 180 115 106 97 89 82 76 69

16 3 388 352 322 295 272 252 234 219 204 192 180 170 161 97 89 82 76 69q2 2867 2842 2820 2801 2784 2768 2754 2742 2730 2719 2709 2700 2692 2684 2677 2670 2664 2658q4 3201 3152 3109 3070 3036 3005 2977 2951 2928 2907 2887 2869 2852 2837 2822 2808 2796 2784

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

Page 13: Floor Deck

Effective June 2009 www.ascsteeldeck.com 13

ASC Steel Deck

N-24 Composite Floor DeckN-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 8 1/4” 3 Hour Fire Rating Slab Weight: 74.0 psf

No. ofSpans

Span

Ga. 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0” 15’6” 16’0”

1 276 245 218 195 175 158 142 129 117 106 96 87 78 71 64 58 52 472 336 305 218 195 175 158 142 129 117 106 96 87 78 71 64 58 52 47

22 3 336 305 218 195 175 158 142 129 117 106 96 87 78 71 64 58 52 47q2 3162 3150 3139 3129 3121 3113 3106 3100 3094 3089 3084 3079 3075 3071 3067 3064 3061 3058q4 3276 3252 3230 3211 3194 3178 3164 3151 3140 3129 3119 3110 3102 3094 3087 3080 3074 30681 439 338 304 274 248 225 205 187 171 156 143 132 121 111 102 94 87 802 439 399 364 334 248 225 205 187 171 156 143 132 121 111 102 94 87 80

20 3 439 399 364 334 308 225 205 187 171 156 143 132 121 111 102 94 87 80q2 3162 3147 3134 3123 3112 3103 3094 3087 3080 3073 3067 3062 3057 3052 3048 3044 3040 3036q4 3323 3293 3267 3244 3223 3205 3188 3173 3159 3146 3134 3123 3113 3104 3095 3087 3079 30721 437 396 362 332 306 222 202 184 169 154 141 130 119 110 101 93 85 782 437 396 362 332 306 284 264 184 169 154 141 130 119 110 101 93 85 78

18 3 437 396 362 332 306 284 264 246 230 154 141 130 119 110 101 93 85 78q2 3185 3165 3148 3132 3118 3106 3095 3085 3075 3067 3059 3052 3045 3039 3033 3028 3022 3018q4 3434 3394 3360 3329 3301 3277 3254 3234 3215 3198 3182 3168 3154 3142 3130 3120 3109 31001 433 393 330 304 281 262 244 182 166 152 139 128 117 108 99 91 83 772 433 393 330 304 281 262 244 228 166 152 139 128 117 108 99 91 83 77

16 3 433 393 330 304 281 262 244 228 214 201 190 128 117 108 99 91 83 77q2 3225 3201 3179 3160 3143 3127 3113 3100 3089 3078 3068 3059 3051 3043 3036 3029 3022 3016q4 3560 3511 3468 3429 3395 3364 3335 3310 3287 3265 3246 3228 3211 3195 3181 3168 3154 3142

1. In shaded areas, mid-span deck shoring required during construction.2. q2 and q4 “q”=allowable diaphragm shear (plf): “2”, “4”=number of welds to support.3. See pg. 55 for General Notes.

Page 14: Floor Deck

14 Preformed Metal Floor Deck

ASC Steel Deck

2W Composite Floor Deck12”

2-1/8”

5”

36”

5”

FD_3 2W-36

3 Welds 4 Welds2W also available in 24” coverage

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

2W - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

22 1.63 0.38 0.298 0.33921 1.73 0.423 0.338 0.37620 1.95 0.465 0.397 0.41119 2.28 0.543 0.464 0.48118 2.57 0.601 0.535 0.53816 3.21 0.752 0.670 0.670

2W - Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

22164 185 206 227 248 269 291415 455 504 567 631 694 758

21242 271 299 327 355 384 412552 601 645 721 797 873 949

20286 318 350 382 414 446 477628 680 733 804 886 968 1051

19464 509 554 598 643 688 732930 997 1063 1130 1224 1329 1433

18615 669 723 777 831 884 9381181 1258 1334 1411 1493 1613 1733

161054 1130 1207 1283 1360 1436 15121902 2003 2104 2205 2306 2407 2544

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4” Slab Weight: 27.6 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 243 210 183 161 119 104 91 80 71 62 55 49 432 243 210 183 161 143 127 115 104 71 62 55 49 43

22 3 243 210 183 161 143 127 115 104 71 62 55 49 43q3 1348 1328 1310 1294 1281 1269 1259 1249 1241 1233 1226 1220 1214q4 1493 1456 1424 1396 1372 1351 1332 1315 1299 1285 1273 1261 12511 259 223 195 172 153 137 99 88 78 69 61 55 492 259 223 195 172 153 137 123 111 101 69 61 55 49

21 3 259 223 195 172 153 137 123 111 101 93 61 55 49q3 1357 1334 1314 1296 1281 1267 1255 1245 1235 1226 1218 1211 1204q4 1537 1494 1458 1426 1399 1374 1353 1333 1316 1300 1286 1273 12611 267 231 202 178 158 142 128 92 81 72 64 58 512 267 231 202 178 158 142 128 116 105 96 64 58 51

20 3 267 231 202 178 158 142 128 116 105 96 88 58 51q3 1364 1339 1317 1299 1283 1268 1256 1244 1234 1225 1216 1208 1201q4 1560 1515 1476 1443 1414 1388 1365 1344 1326 1309 1294 1280 12671 299 259 227 200 178 160 145 131 120 110 77 69 622 299 259 227 200 178 160 145 131 120 110 93 69 62

19 3 299 259 227 200 178 160 145 131 120 110 93 86 62q3 1393 1363 1338 1315 1296 1279 1263 1250 1237 1226 1216 1207 1198q4 1647 1593 1547 1507 1471 1440 1413 1388 1366 1346 1328 1311 12961 323 280 246 218 194 175 158 143 131 120 111 78 712 323 280 246 218 194 175 158 143 131 120 111 102 95

18 3 323 280 246 218 194 175 158 143 131 120 111 102 95q3 1419 1386 1357 1332 1310 1291 1274 1259 1245 1232 1221 1201 1192q4 1714 1653 1601 1556 1517 1482 1452 1424 1399 1377 1356 1338 13201 392 342 301 268 240 216 196 179 164 151 139 129 952 392 342 301 268 240 216 196 179 164 151 139 129 120

16 3 392 342 301 268 240 216 196 179 164 151 139 129 120q3 1493 1451 1415 1383 1356 1332 1310 1291 1274 1258 1244 1231 1219q4 1883 1807 1742 1685 1636 1592 1554 1519 1488 1460 1434 1411 1389

Page 15: Floor Deck

Effective June 2009 www.ascsteeldeck.com 15

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4 1/2” 1 Hour Fire Rating Slab Weight: 32.1 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 273 236 205 181 133 116 102 89 79 70 61 54 482 273 236 205 181 160 143 129 89 79 70 61 54 48

22 3 273 236 205 181 160 143 129 89 79 70 61 54 48q3 1506 1486 1468 1452 1439 1427 1417 1407 1399 1391 1384 1378 1372q4 1651 1614 1582 1554 1530 1509 1490 1473 1457 1443 1431 1419 14091 291 251 219 193 172 126 111 98 86 77 68 61 542 291 251 219 193 172 153 138 125 114 77 68 61 54

21 3 291 251 219 193 172 153 138 125 114 77 68 61 54q3 1515 1492 1472 1454 1439 1425 1413 1403 1393 1384 1376 1369 1362q4 1695 1652 1616 1584 1557 1532 1511 1491 1474 1458 1444 1431 14191 300 259 226 200 177 159 116 102 91 80 72 64 572 300 259 226 200 177 159 143 130 118 80 72 64 57

20 3 300 259 226 200 177 159 143 130 118 108 72 64 57q3 1522 1497 1475 1457 1441 1426 1414 1402 1392 1383 1374 1366 1359q4 1718 1673 1634 1601 1571 1546 1523 1502 1484 1467 1452 1438 14251 335 290 254 224 200 179 162 147 134 95 85 76 692 335 290 254 224 200 179 162 147 134 123 113 76 69

19 3 335 290 254 224 200 179 162 147 134 123 113 104 97q3 1551 1521 1495 1473 1454 1437 1421 1408 1395 1384 1374 1365 1356q4 1805 1751 1705 1665 1629 1598 1571 1546 1524 1504 1486 1469 14541 361 314 275 244 217 195 177 161 147 135 96 86 782 361 314 275 244 217 195 177 161 147 135 124 115 78

18 3 361 314 275 244 217 195 177 161 147 135 124 115 106q3 1577 1544 1515 1490 1468 1449 1432 1417 1403 1390 1379 1369 1359q4 1872 1811 1759 1714 1675 1640 1610 1582 1557 1535 1514 1496 14781 437 381 336 299 267 241 219 200 183 168 155 144 1052 437 381 336 299 267 241 219 200 183 168 155 144 134

16 3 437 381 336 299 267 241 219 200 183 168 155 144 134q3 1651 1609 1573 1541 1514 1490 1468 1449 1432 1416 1402 1387 1377q4 2041 1965 1900 1843 1794 1750 1712 1677 1646 1618 1592 1569 1547

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 16: Floor Deck

16 Preformed Metal Floor Deck

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 1/4” 2 Hour Fire Rating Slab Weight: 38.9 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 322 278 242 180 156 136 119 105 92 81 72 63 562 322 278 242 213 189 169 119 105 92 81 72 63 56

22 3 322 278 242 213 189 169 119 105 92 81 72 63 56q3 1743 1723 1705 1689 1676 1664 1654 1644 1636 1628 1621 1615 1609q4 1888 1851 1819 1791 1767 1746 1726 1709 1694 1680 1668 1656 16461 342 295 258 227 169 148 130 114 101 90 79 71 632 342 295 258 227 202 181 163 147 101 90 79 71 63

21 3 342 295 258 227 202 181 163 147 101 90 79 71 63q3 1752 1729 1709 1691 1676 1662 1650 1640 1630 1621 1613 1606 1599q4 1932 1889 1853 1821 1794 1769 1748 1728 1711 1695 1681 1668 16561 353 305 266 235 209 154 135 119 106 94 84 74 662 353 305 266 235 209 187 168 152 106 94 84 74 66

20 3 353 305 266 235 209 187 168 152 139 94 84 74 66q3 1759 1734 1712 1694 1678 1663 1650 1639 1629 1620 1611 1603 1596q4 1955 1910 1871 1838 1808 1783 1760 1739 1721 1704 1689 1675 16621 393 340 298 263 235 210 190 172 124 111 99 89 802 393 340 298 263 235 210 190 172 157 144 99 89 80

19 3 393 340 298 263 235 210 190 172 157 144 133 123 80q3 1788 1758 1732 1710 1691 1674 1658 1645 1632 1621 1611 1602 1593q4 2042 1988 1942 1902 1866 1835 1808 1783 1761 1741 1723 1706 16911 424 368 323 286 255 229 207 188 172 124 112 101 912 424 368 323 286 255 229 207 188 172 158 145 101 91

18 3 424 368 323 286 255 229 207 188 172 158 145 134 125q3 1814 1781 1752 1727 1705 1686 1669 1654 1640 1627 1616 1606 1596q4 2109 2048 1996 1951 1912 1877 1847 1819 1794 1772 1751 1733 17151 511 445 393 349 313 282 256 233 214 197 182 134 1222 511 445 393 349 313 282 256 233 214 197 182 168 157

16 3 511 445 393 349 313 282 256 233 214 197 182 168 157q3 1888 1846 1809 1778 1751 1727 1705 1686 1669 1653 1639 1626 1614q4 2278 2202 2137 2080 2031 1987 1949 1914 1883 1855 1829 1806 1784

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 17: Floor Deck

Effective June 2009 www.ascsteeldeck.com 17

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 6 3/16” 3 Hour Fire Rating Slab Weight: 47.5 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 385 332 250 215 187 162 142 125 110 97 86 76 672 385 332 290 255 226 162 142 125 110 97 86 76 67

22 3 385 332 290 255 226 162 142 125 110 97 86 76 67q3 2039 2019 2001 1986 1972 1960 1950 1940 1932 1924 1917 1911 1905q4 2184 2147 2115 2087 2063 2042 2023 2006 1990 1976 1964 1952 19421 409 353 308 232 202 176 155 136 121 107 95 84 752 409 353 308 272 241 216 155 136 121 107 95 84 75

21 3 409 353 308 272 241 216 194 136 121 107 95 84 75q3 2049 2025 2005 1987 1972 1958 1946 1936 1926 1917 1909 1902 1895q4 2228 2185 2149 2117 2090 2065 2044 2024 2007 1991 1977 1964 19521 422 365 318 281 210 184 161 143 126 112 100 89 792 422 365 318 281 250 223 201 143 126 112 100 89 79

20 3 422 365 318 281 250 223 201 182 126 112 100 89 79q3 2055 2030 2009 1990 1974 1959 1947 1935 1925 1916 1907 1900 1893q4 2251 2206 2167 2134 2105 2079 2056 2035 2017 2000 1985 1971 19581 469 407 356 315 280 252 227 166 148 132 118 106 952 469 407 356 315 280 252 227 206 188 132 118 106 95

19 3 469 407 356 315 280 252 227 206 188 172 159 106 95q3 2084 2054 2029 2006 1987 1970 1954 1941 1928 1917 1907 1898 1890q4 2338 2284 2238 2198 2163 2132 2104 2079 2057 2037 2019 2002 19871 506 439 385 341 304 274 247 225 165 148 133 120 1082 506 439 385 341 304 274 247 225 205 188 133 120 108

18 3 506 439 385 341 304 274 247 225 205 188 174 160 108q3 2110 2077 2048 2023 2001 1982 1965 1950 1936 1923 1912 1902 1892q4 2405 2344 2293 2248 2208 2174 2143 2115 2090 2068 2047 2029 20121 609 531 468 416 373 336 305 278 255 235 176 160 1462 609 531 468 416 373 336 305 278 255 235 217 201 146

16 3 609 531 468 416 373 336 305 278 255 235 217 201 187q3 2184 2142 2106 2074 2047 2023 2001 1982 1965 1949 1935 1922 1910q4 2574 2498 2433 2376 2327 2284 2245 2210 2179 2151 2125 2102 2080

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 18: Floor Deck

18 Preformed Metal Floor Deck

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 4” Slab Weight: 36.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 243 210 183 130 112 97 84 73 63 55 48 42 362 243 210 183 160 143 127 115 73 63 55 48 42 36

22 3 243 210 183 160 143 127 84 73 63 55 48 42 36q3 1673 1652 1634 1619 1605 1594 1583 1574 1565 1557 1550 1544 1538q4 1818 1780 1748 1721 1696 1675 1656 1639 1624 1610 1597 1586 15751 259 223 195 172 153 106 92 80 70 62 54 47 412 259 223 195 172 153 137 123 111 70 62 54 47 41

21 3 259 223 195 172 153 137 123 111 70 62 54 47 41q3 1682 1658 1638 1621 1605 1592 1580 1569 1559 1551 1543 1535 1529q4 1861 1819 1782 1751 1723 1699 1677 1658 1640 1624 1610 1597 15851 267 231 202 178 158 110 96 84 74 65 57 50 442 267 231 202 178 158 142 128 116 74 65 57 50 44

20 3 267 231 202 178 158 142 128 116 105 65 57 50 44q3 1688 1663 1642 1623 1607 1593 1580 1569 1558 1549 1541 1533 1526q4 1884 1839 1801 1767 1738 1712 1689 1669 1650 1633 1618 1604 15921 299 259 227 200 178 160 145 131 88 78 69 62 552 299 259 227 200 178 160 145 131 120 110 69 62 55

19 3 299 259 227 200 178 160 145 131 120 110 101 93 55q3 1718 1688 1662 1640 1620 1603 1588 1574 1562 1551 1541 1531 1523q4 1972 1918 1871 1831 1796 1765 1737 1713 1690 1670 1652 1635 16201 323 280 246 218 194 175 158 143 131 120 79 71 632 323 280 246 218 194 175 158 143 131 120 111 71 63

18 3 323 280 246 218 194 175 158 143 131 120 111 102 95q3 1744 1710 1681 1656 1635 1615 1598 1583 1569 1557 1545 1535 1526q4 2038 1978 1926 1881 1842 1807 1776 1748 1724 1701 1681 1662 16451 392 342 301 268 240 216 196 179 164 151 139 97 882 392 342 301 268 240 216 196 179 164 151 139 129 120

16 3 392 342 301 268 240 216 196 179 164 151 139 129 120q3 1817 1775 1739 1708 1680 1656 1635 1616 1598 1583 1568 1555 1543q4 2207 2131 2066 2010 1960 1917 1878 1843 1812 1784 1758 1735 1714

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 19: Floor Deck

Effective June 2009 www.ascsteeldeck.com 19

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 4 1/2” Slab Weight: 42.3 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 273 236 170 145 125 108 93 81 70 61 53 46 402 273 236 205 181 160 143 93 81 70 61 53 46 40

22 3 273 236 205 181 160 143 93 81 70 61 53 46 40q3 1912 1891 1873 1858 1845 1833 1822 1813 1804 1797 1790 1783 1777q4 2057 2020 1988 1960 1936 1914 1895 1878 1863 1849 1836 1825 18141 291 251 219 193 136 118 102 89 78 68 60 52 462 291 251 219 193 172 153 138 89 78 68 60 52 46

21 3 291 251 219 193 172 153 138 125 78 68 60 52 46q3 1921 1897 1877 1860 1844 1831 1819 1808 1798 1790 1782 1774 1768q4 2100 2058 2021 1990 1962 1938 1916 1897 1879 1864 1849 1836 18241 300 259 226 200 177 123 107 94 82 72 63 56 492 300 259 226 200 177 159 143 94 82 72 63 56 49

20 3 300 259 226 200 177 159 143 130 118 72 63 56 49q3 1927 1902 1881 1862 1846 1832 1819 1808 1797 1788 1780 1772 1765q4 2123 2078 2040 2006 1977 1951 1928 1908 1889 1872 1857 1843 18311 335 290 254 224 200 179 162 111 98 87 77 68 602 335 290 254 224 200 179 162 147 134 87 77 68 60

19 3 335 290 254 224 200 179 162 147 134 123 113 68 60q3 1957 1927 1901 1879 1859 1842 1827 1813 1801 1790 1780 1770 1762q4 2211 2157 2110 2070 2035 2004 1976 1952 1930 1910 1891 1875 18591 361 314 275 244 217 195 177 161 147 98 87 78 702 361 314 275 244 217 195 177 161 147 135 87 78 70

18 3 361 314 275 244 217 195 177 161 147 135 124 115 70q3 1983 1949 1920 1896 1874 1854 1837 1822 1808 1796 1785 1774 1765q4 2277 2217 2165 2120 2081 2046 2015 1988 1963 1940 1920 1901 18841 437 381 336 299 267 241 219 200 183 168 118 107 972 437 381 336 299 267 241 219 200 183 168 155 144 134

16 3 437 381 336 299 267 241 219 200 183 168 155 144 134q3 2056 2014 1978 1947 1919 1895 1874 1855 1837 1822 1807 1794 1783q4 2446 2370 2305 2249 2199 2156 2117 2083 2051 2023 1998 1974 1953

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 20: Floor Deck

20 Preformed Metal Floor Deck

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5 1/2” 1 Hour Fire Rating Slab Weight: 54.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 339 247 209 179 153 132 114 99 86 75 65 56 482 339 292 254 224 153 132 114 99 86 75 65 56 48

22 3 339 292 254 224 153 132 114 99 86 75 65 56 48q3 2390 2369 2352 2336 2323 2311 2300 2291 2282 2275 2268 2261 2255q4 2535 2498 2466 2438 2414 2392 2373 2356 2341 2327 2314 2303 22921 360 311 271 194 167 145 126 109 95 83 73 63 552 360 311 271 239 212 145 126 109 95 83 73 63 55

21 3 360 311 271 239 212 190 126 109 95 83 73 63 55q3 2399 2376 2355 2338 2323 2309 2297 2286 2277 2268 2260 2253 2246q4 2578 2536 2499 2468 2440 2416 2394 2375 2357 2342 2327 2314 23021 371 320 280 201 174 151 132 115 101 88 77 68 592 371 320 280 247 219 196 132 115 101 88 77 68 59

20 3 371 320 280 247 219 196 177 115 101 88 77 68 59q3 2405 2380 2359 2341 2324 2310 2297 2286 2276 2266 2258 2256 2243q4 2602 2557 2518 2484 2455 2429 2406 2386 2367 2351 2335 2322 23091 413 358 313 277 247 221 154 136 120 106 94 83 732 413 358 313 277 247 221 200 181 120 106 94 83 73

19 3 413 358 313 277 247 221 200 181 165 152 94 83 73q3 2435 2405 2379 2357 2337 2320 2305 2291 2279 2268 2258 2249 2240q4 2689 2635 2588 2548 2513 2482 2455 2430 2408 2388 2369 2353 23371 445 386 339 300 268 241 218 152 135 120 107 95 852 445 386 339 300 268 241 218 198 181 120 107 95 85

18 3 445 386 339 300 268 241 218 198 181 166 153 95 85q3 2461 2427 2399 2374 2352 2333 2316 2300 2286 2274 2263 2252 2243q4 2755 2695 2643 2598 2559 2524 2493 2466 2441 2418 2398 2379 23621 536 468 412 367 328 296 269 245 224 160 144 130 1182 536 468 412 367 328 296 269 245 224 207 191 130 118

16 3 536 468 412 367 328 296 269 245 224 207 191 177 164q3 2534 2492 2456 2425 2398 2373 2352 2333 2315 2300 2286 2273 2261q4 2924 2848 2783 2727 2678 2634 2595 2561 2530 2501 2476 2452 2431

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 21: Floor Deck

Effective June 2009 www.ascsteeldeck.com 21

ASC Steel Deck

2W Composite Floor Deck2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6” 1 1/2 Hour Fire Rating Slab Weight: 60.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 373 271 230 196 169 145 126 109 94 82 71 61 532 373 321 280 246 169 145 126 109 94 82 71 61 53

22 3 373 321 280 246 169 145 126 109 94 82 71 61 53q3 2629 2608 2591 2575 2562 2550 2539 2530 2521 2514 2507 2500 2495q4 2774 2737 2705 2677 2653 2631 2612 2595 2580 2566 2554 2542 25311 396 342 248 213 183 159 138 120 105 91 80 70 602 396 342 298 263 233 159 138 120 105 91 80 70 60

21 3 396 342 298 263 233 209 138 120 105 91 80 70 60q3 2638 2615 2594 2577 2562 2548 2536 2525 2516 2507 2499 2492 2485q4 2817 2775 2739 2707 2679 2655 2633 2614 2597 2581 2566 2553 25411 408 352 308 221 191 166 144 126 110 97 85 74 652 408 352 308 271 241 166 144 126 110 97 85 74 65

20 3 408 352 308 271 241 216 144 126 110 97 85 74 65q3 2645 2620 2598 2580 2563 2549 2536 2525 2516 2505 2497 2489 2482q4 2841 2796 2757 2724 2694 2668 2645 2625 2606 2590 2574 2561 25481 454 393 344 304 271 193 169 149 131 116 103 91 802 454 393 344 304 271 243 220 149 131 116 103 91 80

19 3 454 393 344 304 271 243 220 199 182 116 103 91 80q3 2674 2644 2618 2596 2577 2559 2544 2530 2518 2507 2497 2488 2479q4 2928 2874 2828 2787 2752 2721 2694 2669 2647 2627 2609 2592 25771 489 425 373 330 294 265 188 167 148 131 117 104 932 489 425 373 330 294 265 239 217 148 131 117 104 93

18 3 489 425 373 330 294 265 239 217 199 182 117 104 93q3 2700 2666 2638 2613 2591 2572 2555 2539 2526 2513 2502 2491 2482q4 2995 2934 2882 2837 2798 2763 2732 2705 2680 2657 2637 2618 26011 589 514 453 403 361 325 295 269 195 175 158 143 1292 589 514 453 403 361 325 295 269 246 227 158 143 129

16 3 589 514 453 403 361 325 295 269 246 227 210 194 129q3 2773 2731 2695 2664 2637 2613 2591 2572 2555 2539 2525 2512 2500q4 3164 3088 3022 2966 2917 2873 2834 2800 2769 2740 2715 2691 2670

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 22: Floor Deck

22 Preformed Metal Floor Deck

2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6 1/2” 2 Hour Fire Rating Slab Weight: 66.5 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 352 296 251 214 184 159 137 119 103 89 77 67 572 407 351 306 214 184 159 137 119 103 89 77 67 57

22 3 407 351 306 214 184 159 137 119 103 89 77 67 57q3 2868 2847 2830 2814 2801 2789 2769 2761 2753 2746 2739 2734 2728q4 3013 2976 2944 2916 2892 2870 2851 2834 2819 2805 2793 2781 27711 432 373 271 232 200 173 150 131 114 100 87 76 662 432 373 326 287 200 173 150 131 114 100 87 76 66

21 3 432 373 326 287 255 173 150 131 114 100 87 76 66q3 2877 2854 2834 2816 2801 2787 2775 2764 2755 2746 2738 2731 2724q4 3057 3014 2978 2946 2919 2894 2872 2853 2836 2820 2806 2792 27801 446 385 281 242 209 181 158 138 120 105 92 81 702 446 385 336 296 264 181 158 138 120 105 92 81 70

20 3 446 385 336 296 264 236 158 138 120 105 92 81 70q3 2884 2859 2837 2819 2802 2788 2775 2764 2754 2744 2736 2728 2721q4 3080 3035 2996 2963 2933 2908 2885 2864 2846 2829 2814 2800 27871 495 429 376 332 241 210 184 162 143 126 112 99 882 495 429 376 332 296 266 184 162 143 126 112 99 88

19 3 495 429 376 332 296 266 240 218 143 126 112 99 88q3 2913 2883 2857 2835 2816 2798 2783 2769 2757 2746 2736 2727 2718q4 3167 3113 3067 3026 2991 2960 2933 2908 2886 2866 2848 2831 28161 534 464 407 360 321 289 206 182 161 143 128 114 1012 534 464 407 360 321 289 261 182 161 143 128 114 101

18 3 534 464 407 360 321 289 261 237 217 143 128 114 101q3 2939 2906 2877 2852 2830 2811 2778 2765 2752 2741 2731 2721 2712q4 3234 3173 3121 3076 3037 3002 2971 2944 2919 2897 2876 2857 28401 643 561 494 439 394 355 322 294 213 191 172 156 1412 643 561 494 439 394 355 322 294 269 191 172 156 141

16 3 643 561 494 439 394 355 322 294 269 248 229 212 141q3 3013 2970 2934 2903 2876 2852 2830 2811 2794 2778 2764 2751 2739q4 3403 3327 3262 3205 3156 3112 3074 3039 3008 2979 2954 2930 2909

ASC Steel Deck

2W Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 23: Floor Deck

Effective June 2009 www.ascsteeldeck.com 23

2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 7 1/4” 3 Hour Fire Rating Slab Weight: 75.6 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

1 398 334 283 242 208 179 155 134 116 101 87 75 652 460 396 345 242 208 179 155 134 116 101 87 75 65

22 3 460 396 345 242 208 179 155 134 116 101 87 75 65q3 3227 3206 3188 3173 3160 3148 3137 3128 3119 3111 3104 3098 3092q4 3372 3334 3302 3275 3250 3229 3210 3193 3178 3164 3151 3140 31291 488 359 306 262 226 195 170 148 129 112 98 85 742 488 421 368 324 226 195 170 148 129 112 98 85 74

21 3 488 421 368 324 226 195 170 148 129 112 98 85 74q3 3236 3212 3192 3175 3159 3146 3134 3123 3113 3105 3097 3089 3083q4 3415 3373 3336 3305 3277 3253 3231 3212 3194 3179 3164 3151 31391 503 435 317 273 235 204 178 155 136 119 104 91 792 503 435 380 335 235 204 178 155 136 119 104 91 79

20 3 503 435 380 335 297 204 178 155 136 119 104 91 79q3 3342 3217 3196 3177 3161 3147 3134 3123 3112 3103 3095 3087 3080q4 3438 3393 3355 3321 3292 3266 3243 3223 3204 3187 3172 3158 31461 559 484 424 375 272 237 208 183 161 143 126 112 992 559 484 424 375 334 300 208 183 161 143 126 112 99

19 3 559 484 424 375 334 300 271 183 161 143 126 112 99q3 3272 3242 3216 3194 3174 3157 3142 3128 3116 3105 3095 3085 3077q4 3526 3472 3425 3385 3350 3319 3291 3267 3245 3224 3206 3190 31741 603 523 459 407 363 263 232 205 182 162 144 128 1142 603 523 459 407 363 326 232 205 182 162 144 128 114

18 3 603 523 459 407 363 326 295 268 182 162 144 128 114q3 3298 3264 3235 3210 3189 3169 3152 3137 3123 3111 3100 3089 3080q4 3592 3532 3480 3435 3396 3361 3330 3302 3278 3255 3235 3216 31991 725 633 557 496 444 400 363 268 240 216 195 176 1592 725 633 557 496 444 400 363 331 240 216 195 176 159

16 3 725 633 557 496 444 400 363 331 303 279 258 176 159q3 3371 3329 3293 3262 3234 3210 3189 3170 3152 3137 3122 3109 3098q4 3761 3685 3620 3564 3514 3471 3432 3398 3366 3338 3312 3289 3268

ASC Steel Deck

2W Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 24: Floor Deck

24 Preformed Metal Floor Deck

ASC Steel Deck

2W Superimposed Load with Studs at SupportsAllowable Superimposed Load (psf) for 2W Deck When 3/4” Diameter Studs are used at the Supporting Beams

ConcreteSlab & TypeThickness 6’0” 7’0”

Studs at 1’0” OC

11’0” 12’0” 6’0” 7’0”

Studs at 3’0” OC

11’0” 12’0”

Span Span

8’0” 9’0” 10’0” 8’0” 9’0” 10’0”

4 1/2” LTWT

22 400 320 240 185 145 115 90 345 245 180 16 125 100 8020 400 390 295 225 180 145 115 400 280 195 135 155 125 10518 400 400 370 295 235 180 140 400 390 280 205 155 115 14016 400 400 370 330 265 195 150 400 400 360 270 205 155 120

5 1/4” LTWT

22 400 395 295 225 175 140 115 400 305 260 200 155 120 9520 400 400 360 280 220 175 145 400 335 230 170 195 155 12518 400 400 400 370 295 235 195 400 400 340 245 175 210 17516 400 400 400 400 360 300 235 400 400 400 325 240 180 130

6 1/2” LTWT

22 400 400 385 295 235 185 150 400 400 345 260 200 155 12020 400 400 400 370 290 235 190 400 400 295 330 255 200 16018 400 400 400 400 390 315 260 400 400 400 290 200 280 23016 400 400 400 400 400 400 330 400 400 400 400 290 205 290

4 1/2” NWT

22 400 315 230 175 135 105 85 400 290 215 165 125 100 8020 400 385 285 220 170 135 110 400 290 215 160 160 125 10518 400 400 375 290 230 185 150 400 390 275 200 140 175 14016 400 400 400 360 285 230 190 400 400 360 265 195 145 180

5 1/2” NWT

22 400 400 305 230 180 140 110 400 380 280 215 165 130 10020 400 400 375 290 225 180 145 400 380 280 265 205 165 13018 400 400 400 385 305 245 200 400 400 340 235 285 230 18516 400 400 400 400 385 310 255 400 400 400 325 235 290 235

6 1/2” NWT

22 400 400 375 285 225 175 140 400 400 350 265 205 160 12520 400 400 400 360 280 225 180 400 400 400 325 250 195 15518 400 400 400 400 380 305 250 400 400 390 260 355 280 22516 400 400 400 400 400 390 320 400 400 400 375 255 360 295

1. See 2W tables for shoring requirements.2. “SLAB” thickness is the total slab thickness.

Page 25: Floor Deck

Effective June 2009 www.ascsteeldeck.com 25

ASC Steel Deck

2WF Composite Floor Deck12”

2-1/8”

5”

36”

5”

FD_4 2WF-36

3 Welds 4 Welds2WF also available in 24” coverage

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

2WF - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20/20 3.60 0.674 0.416 0.43520/18 4.18 0.741 0.423 0.45120/16 4.55 0.797 0.429 0.46318/20 4.15 0.901 0.601 0.60018/18 4.67 0.928 0.611 0.59218/16 5.10 1.003 0.621 0.60816/16 5.79 1.196 0.771 0.749

2WF - Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

20/20 286 318 350 382 414 446 477628 680 733 804 886 968 1051

20/18 286 318 350 382 414 446 477628 680 733 804 886 968 1051

20/16 286 318 350 382 414 446 477628 680 733 804 886 968 1051

18/20 615 669 723 777 831 884 9381181 1258 1334 1411 1493 1613 1733

18/18 615 669 723 777 831 884 9381181 1258 1334 1411 1493 1613 1733

18/16 615 669 723 777 831 884 9381181 1258 1334 1411 1493 1613 1733

16/16 1054 1130 1207 1283 1360 1436 15121902 2003 2104 2205 2306 2407 2544

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4” Slab Weight: 27.6 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

20/20

1 289 250 218 193 171 153 138 125 89 79 71 63 562 289 250 218 193 171 153 138 125 114 104 96 63 563 289 250 218 193 171 153 138 125 114 104 96 88 82q3 1488 1447 1411 1380 1353 1329 1308 1289 1272 1256 1242 1230 1218

20/18

1 291 252 220 194 172 154 139 126 89 79 71 63 572 291 252 220 194 172 154 139 126 115 105 96 63 573 291 252 220 194 172 154 139 126 115 105 96 89 82q3 1571 1521 1478 1441 1408 1380 1354 1331 1310 1292 1275 1259 1245

20/16

1 292 252 220 194 173 155 139 126 115 79 70 63 562 292 252 220 194 173 155 139 126 115 105 97 63 563 292 252 220 194 173 155 139 126 115 105 97 89 92q3 1661 1602 1552 1508 1470 1436 1406 1380 1355 1334 1314 1296 1279

18/20

1 348 302 265 234 209 188 170 154 141 129 119 110 1022 348 302 265 234 209 188 170 154 141 129 119 110 1023 348 302 265 234 209 188 170 154 141 129 119 110 102q3 1543 1496 1455 1420 1389 1362 1338 1316 1297 1279 1263 1249 1235

18/18

1 350 304 267 236 211 189 171 156 142 130 120 111 1032 350 304 267 236 211 189 171 156 142 130 120 111 1033 350 304 267 236 211 189 171 156 142 130 120 111 103q3 1631 1575 1527 1485 1449 1417 1388 1363 1340 1319 1300 1283 1267

18/16

1 366 318 279 247 220 198 179 163 148 136 125 116 1082 366 318 279 247 220 198 179 163 148 136 125 116 1083 366 318 279 247 220 198 179 163 148 136 125 116 108q3 1723 1659 1603 1556 1514 1477 1444 1414 1388 1364 1342 1322 1304

16/16

1 425 371 327 290 260 235 213 194 178 164 151 140 1302 425 371 327 290 260 235 213 194 178 164 151 140 1303 425 371 327 290 260 235 213 194 178 164 151 140 130q3 1787 1717 1657 1604 1559 1519 1483 1451 1422 1396 1372 1351 1331

Page 26: Floor Deck

26 Preformed Metal Floor Deck

ASC Steel Deck

2WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 4 1/2” 1 Hour Fire Rating Slab Weight: 32.1 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

20/20

1 322 279 243 215 191 171 154 139 98 87 78 70 622 322 279 243 215 191 171 154 139 127 116 78 70 62

3 322 279 243 215 191 171 154 139 127 116 107 98 62

q3 1646 1605 1569 1538 1511 1487 1466 1447 1430 1414 1400 1387 1376

20/18

1 324 280 245 216 192 172 155 140 98 88 78 70 62

2 324 280 245 216 192 172 155 140 128 117 78 70 62

3 324 280 245 216 192 172 155 140 128 117 107 99 62

q3 1729 1679 1636 1599 1566 1538 1512 1489 1468 1450 1433 1417 1403

20/16

1 325 281 246 216 192 172 155 141 98 87 78 70 62

2 325 281 246 216 192 172 155 141 128 117 78 70 62

3 325 281 246 216 192 172 155 141 128 117 108 99 62

q3 1819 1760 1710 1666 1628 1594 1564 1538 1513 1492 1472 1454 1437

18/20

1 386 335 294 260 232 209 189 172 157 144 132 122 84

2 386 335 294 260 232 209 189 172 157 144 132 122 114

3 386 335 294 260 232 209 189 172 157 144 132 122 114

q3 1701 1654 1613 1578 1547 1520 1496 1474 1455 1437 1421 1407 1393

18/18

1 389 338 296 262 234 210 190 173 158 145 133 123 85

2 389 338 296 262 234 210 190 173 158 145 133 123 114

3 389 338 296 262 234 210 190 173 158 145 133 123 114

q3 1789 1733 1685 1643 1607 1575 1546 1521 1498 1477 1458 1441 1425

18/16

1 404 351 308 272 243 218 197 180 164 150 139 128 90

2 404 351 308 272 243 218 197 180 164 150 139 128 119

3 404 351 308 272 243 218 197 180 164 150 139 128 110

q3 1881 1817 1761 1714 1672 1635 1602 1572 1546 1522 1500 1480 1462

16/16

1 471 411 362 322 288 260 236 215 197 181 167 155 144

2 471 411 362 322 288 260 236 215 197 181 167 155 144

3 471 411 362 322 288 260 236 215 197 181 167 155 144

q3 1945 1875 1814 1762 1717 1677 1641 1609 1580 1554 1530 1509 1489

Page 27: Floor Deck

Effective June 2009 www.ascsteeldeck.com 27

ASC Steel Deck

2WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 1/4” 2 Hour Fire Rating Slab Weight: 38.9 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

20/20

1 375 324 283 250 222 199 145 128 113 101 90 80 712 375 324 283 250 222 199 179 162 148 101 90 80 71

3 375 324 283 250 222 199 179 162 148 135 124 80 71

q3 1883 1842 1806 1775 1748 1724 1703 1684 1667 1651 1637 1624 1613

20/18

1 377 325 284 251 223 199 180 128 114 101 90 89 72

2 377 325 284 251 223 199 180 163 148 101 90 80 72

3 377 325 284 251 223 199 180 163 148 136 125 80 72

q3 1966 1916 1873 1836 1803 1774 1749 1726 1705 1687 1670 1654 1640

20/16

1 378 326 285 251 223 200 180 128 114 101 90 80 71

2 378 326 285 251 223 200 180 163 149 101 90 80 71

3 378 326 285 251 223 200 180 163 149 136 125 80 71

q3 2056 1997 1947 1903 1865 1831 1801 1775 1750 1729 1709 1691 1674

18/20

1 448 389 341 302 270 242 219 199 182 167 154 107 97

2 448 389 341 302 270 242 219 199 182 167 154 142 97

3 448 389 341 302 270 242 219 199 182 167 154 142 132

q3 1938 1890 1850 1815 1784 1757 1733 1711 1692 1674 1658 1644 1630

18/18

1 451 391 343 304 271 244 220 200 183 168 155 108 97

2 451 391 343 304 271 244 220 200 183 168 155 143 97

3 451 391 343 304 271 244 220 200 183 168 155 143 133

q3 2026 1970 1922 1880 1844 1812 1783 1758 1735 1714 1695 1678 1662

18/16

1 465 404 355 314 280 252 228 207 189 173 160 113 102

2 465 404 355 314 280 252 228 207 189 173 160 148 102

3 465 404 355 314 280 252 228 207 189 173 160 148 137

q3 2118 2054 1998 1950 1909 1872 1839 1809 1783 1759 1737 1717 1699

16/16

1 544 474 418 372 333 300 272 248 228 209 193 179 167

2 544 474 418 372 333 300 272 248 228 209 193 179 167

3 544 474 418 372 333 300 272 248 228 209 193 179 167

q3 2182 2112 2051 1999 1954 1913 1878 1846 1817 1791 1767 1745 1726

Page 28: Floor Deck

28 Preformed Metal Floor Deck

ASC Steel Deck

2WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 4” Slab Weight: 36.4 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

20/20

1 289 250 218 193 171 153 138 93 82 72 63 56 492 289 250 218 193 171 153 138 125 114 72 63 56 49

3 289 250 218 193 171 153 138 125 114 104 96 56 49

q3 1813 1771 1735 1705 1677 1654 1632 1613 1596 1581 1567 1554 1542

20/18

1 291 252 220 194 172 154 139 93 82 72 63 56 49

2 291 252 220 194 172 154 139 126 115 72 63 56 49

3 291 252 220 194 172 154 139 126 115 105 96 56 49

q3 1896 1846 1803 1765 1733 1704 1678 1656 1635 1616 1599 1584 1570

20/16

1 292 252 220 194 173 155 139 93 82 72 63 56 49

2 292 252 220 194 173 155 139 126 115 105 63 56 49

3 292 252 220 194 173 155 139 126 115 105 97 56 49

q3 1985 1927 1876 1833 1794 1761 1731 1704 1680 1658 1638 1620 1604

18/20

1 348 302 265 234 209 188 170 154 141 129 119 77 69

2 348 302 265 234 209 188 170 154 141 129 119 110 69

3 348 302 265 234 209 188 170 154 141 129 119 110 102

q3 1867 1820 1779 1744 1713 1686 1662 1641 1621 1604 1588 1573 1560

18/18

1 350 304 267 236 211 189 171 156 142 130 120 78 70

2 350 304 267 236 211 189 171 156 142 130 120 111 70

3 350 304 267 236 211 189 171 156 142 130 120 111 103

q3 1955 1899 1851 1810 1773 1741 1713 1687 1664 1644 1625 1607 1592

18/16

1 366 318 279 247 220 198 179 163 148 136 125 83 75

2 366 318 279 247 220 198 179 163 148 136 125 116 108

3 366 318 279 247 220 198 179 163 148 136 125 116 108

q3 2048 1983 1928 1880 1838 1801 1768 1739 1712 1688 1667 1647 1629

16/16

1 425 371 327 290 260 235 213 194 178 164 151 140 130

2 425 371 327 290 260 235 213 194 178 164 151 140 130

3 425 371 327 290 260 235 213 194 178 164 151 140 130

q3 2111 2041 1981 1929 1883 1843 1807 1775 1746 1720 1697 1675 1655

Page 29: Floor Deck

Effective June 2009 www.ascsteeldeck.com 29

ASC Steel Deck

2WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 4 1/2” Slab Weight: 42.3 psf

No. ofSpans

Span

Gauge 6’0” 6’6” 7’0” 7’6” 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0”

20/20

1 322 279 243 215 191 171 117 102 90 79 69 61 542 322 279 243 215 191 171 154 139 90 79 69 61 54

3 322 279 243 215 191 171 154 139 127 116 69 61 54

q3 2052 2010 1975 1944 1917 1893 1871 1852 1835 1820 1806 1793 1781

20/18

1 324 280 245 216 192 172 117 103 90 79 70 61 54

2 324 280 245 216 192 172 155 140 90 79 70 61 54

3 324 280 245 216 192 172 155 140 128 117 70 61 54

q3 2135 2085 2042 2004 1972 1943 1917 1895 1874 1855 1838 1823 1809

20/16

1 325 281 246 216 192 172 117 103 90 79 70 61 54

2 325 281 246 216 192 172 155 141 128 79 70 61 54

3 325 281 245 216 192 172 155 141 128 117 70 61 54

q3 2225 2166 2115 2072 2034 2000 1970 1943 1919 1897 1877 1859 1843

18/20

1 386 335 294 260 232 209 189 172 157 144 95 85 76

2 386 335 294 260 232 209 189 172 157 144 132 85 76

3 386 335 294 260 232 209 189 172 157 144 132 122 114

q3 2106 2059 2018 1983 1953 1925 1901 1880 1860 1843 1827 1812 1799

18/18

1 389 338 296 262 234 210 190 173 158 145 95 85 76

2 389 338 296 262 234 210 190 173 158 145 133 85 76

3 389 338 296 262 234 210 190 173 158 145 133 123 114

q3 2194 2138 2090 2049 2012 1980 1952 1926 1903 1883 1864 1847 1831

18/16

1 404 351 308 272 243 218 197 180 164 150 101 90 81

2 404 351 308 272 243 218 197 180 164 150 139 128 81

3 404 351 308 272 243 218 197 180 164 150 139 128 119

q3 2287 2222 2167 2119 2077 2040 2007 1978 1951 1928 1906 1886 1868

16/16

1 471 411 362 322 288 260 236 215 197 181 167 155 144

2 471 411 362 322 288 260 236 215 197 181 167 155 144

3 471 411 362 322 288 260 236 215 197 181 167 155 144

q3 2350 2280 2220 2168 2122 2082 2046 2014 1985 1959 1936 1914 1894

Page 30: Floor Deck

30 Preformed Metal Floor Deck

ASC Steel Deck

3W Composite Floor Deck12”

36”

3 Welds 4 WeldsAlso available in 24” coverage

4-3/4”

3”

4-3/4”

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

3W - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

22 1.68 0.769 0.433 0.47121 1.83 0.881 0.511 0.54020 2.04 0.938 0.550 0.57419 2.29 1.126 0.692 0.69418 2.70 1.260 0.780 0.77716 3.36 1.582 0.976 0.975

3W - Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

22155 175 195 215 235 255 275402 441 488 550 611 673 734

21232 259 286 313 340 367 395539 586 630 704 778 852 927

20275 306 337 367 398 429 459615 666 717 787 867 948 1028

19452 495 539 582 626 669 713918 983 1049 1114 1208 1311 1414

18602 655 707 760 813 866 9191170 1246 1322 1398 1479 1598 1717

161042 1117 1193 1268 1344 1419 14951898 1998 2099 2200 2300 2401 2538

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5” Slab Weight: 32.0 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 249 228 209 193 151 139 128 118 109 101 93 87 81 74 682 249 228 209 193 178 166 149 118 109 101 93 87 81 74 68

22 3 249 228 209 193 178 166 149 133 120 101 93 87 81 74 68q3 1281 1269 1259 1249 1241 1233 1226 1220 1214 1208 1203 1199 1195 1191 1187q4 1372 1351 1332 1315 1299 1285 1273 1261 1251 1241 1232 1224 1216 1209 12021 272 248 228 210 194 181 141 131 121 112 104 97 90 84 792 272 248 228 210 194 181 169 155 139 112 104 97 90 84 79

21 3 272 248 228 210 194 181 169 155 139 126 113 97 90 84 79q3 1281 1267 1255 1245 1235 1226 1218 1211 1204 1198 1193 1187 1182 1178 1174q4 1399 1374 1353 1333 1316 1300 1286 1273 1261 1250 1239 1230 1221 1213 12051 283 258 237 218 202 188 169 137 127 117 109 102 95 89 832 283 258 237 218 202 188 175 164 149 117 109 102 95 89 83

20 3 283 258 237 218 202 188 175 164 149 134 122 110 95 89 83q3 1283 1268 1256 1244 1234 1225 1216 1208 1201 1195 1189 1183 1178 1173 1169q4 1414 1388 1365 1344 1326 1309 1294 1280 1267 1255 1245 1235 1225 1217 12091 320 292 268 247 229 213 198 186 167 145 127 118 110 103 972 320 292 268 247 229 213 198 186 174 164 150 136 110 103 97

19 3 320 292 268 247 229 213 198 186 174 164 150 136 124 113 97q3 1296 1279 1263 1250 1237 1226 1216 1207 1198 1191 1183 1177 1171 1165 1159q4 1471 1440 1413 1388 1366 1346 1328 1311 1296 1282 1269 1257 1246 1235 12251 345 315 289 267 247 230 214 200 188 171 150 130 121 114 1062 345 315 289 267 247 230 214 200 188 177 167 154 141 114 106

18 3 345 315 289 267 247 230 214 200 188 177 167 154 140 128 117q3 1310 1291 1274 1259 1245 1232 1221 1211 1201 1192 1184 1177 1170 1164 1158q4 1517 1482 1452 1424 1399 1377 1356 1338 1320 1305 1290 1277 1264 1253 12421 403 368 338 312 287 258 232 209 189 172 156 142 129 122 1122 403 368 338 312 287 258 232 209 189 172 156 142 129 122 112

16 3 403 368 338 312 287 258 232 209 189 172 156 142 129 122 112q3 1356 1332 1310 1291 1274 1258 1244 1231 1219 1208 1198 1189 1180 1172 1164q4 1636 1592 1554 1519 1488 1460 1434 1411 1389 1369 1351 1334 1319 1304 1290

Page 31: Floor Deck

Effective June 2009 www.ascsteeldeck.com 31

ASC Steel Deck

3W Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5” Slab Weight: 32.0 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 273 249 229 211 165 151 139 128 118 109 101 94 87 81 762 273 249 229 211 195 181 139 128 118 109 101 94 87 81 76

22 3 273 249 229 211 195 181 169 152 118 109 101 94 87 81 76q3 1439 1427 1417 1407 1399 1391 1384 1378 1372 1366 1361 1357 1353 1349 1345q4 1530 1509 1490 1473 1457 1443 1431 1419 1409 1399 1390 1382 1374 1367 13601 297 271 249 230 213 195 153 142 131 121 113 105 97 91 852 297 271 249 230 213 198 184 172 131 121 113 105 97 91 85

21 3 297 271 249 230 213 198 184 172 159 143 113 105 97 91 85q3 1439 1426 1413 1403 1393 1384 1376 1369 1362 1356 1351 1345 1340 1336 1332q4 1557 1532 1511 1491 1474 1453 1444 1431 1419 1408 1397 1388 1379 1371 13631 309 282 259 239 221 205 161 148 137 127 118 110 102 96 892 309 282 259 239 221 205 192 179 137 127 118 110 102 96 89

20 3 309 282 259 239 221 205 192 179 168 154 139 110 102 96 89q3 1441 1426 1414 1402 1392 1383 1374 1366 1359 1353 1347 1341 1336 1331 1327q4 1571 1546 1523 1502 1484 1467 1452 1438 1425 1413 1403 1393 1383 1375 13661 348 318 292 269 249 232 216 202 179 149 137 128 119 111 1042 348 318 292 269 249 232 216 202 190 178 168 128 119 111 104

19 3 348 318 292 269 249 232 216 202 190 178 168 156 142 111 104q3 1454 1437 1421 1408 1395 1384 1374 1365 1356 1349 1341 1335 1329 1323 1317q4 1629 1598 1571 1546 1524 1504 1486 1469 1454 1440 1427 1415 1404 1393 13831 375 343 315 290 269 250 233 218 204 184 150 140 131 122 1152 375 343 315 290 269 250 233 218 204 192 181 171 131 122 115

18 3 375 343 315 290 269 250 233 218 204 192 181 171 162 148 135q3 1468 1449 1432 1417 1403 1390 1379 1369 1359 1350 1342 1335 1328 1322 1316q4 1675 1640 1610 1582 1557 1535 1514 1496 1478 1463 1448 1435 1422 1411 14001 437 399 366 338 313 291 271 253 238 224 211 199 157 147 1382 437 399 366 338 313 291 271 253 238 224 211 199 189 179 170

16 3 437 399 366 338 313 291 271 253 238 224 211 199 189 179 170q3 1514 1490 1468 1449 1432 1416 1402 1389 1377 1366 1356 1347 1338 1330 1322q4 1794 1750 1712 1677 1646 1618 1592 1569 1547 1527 1509 1492 1477 1462 1448

Page 32: Floor Deck

32 Preformed Metal Floor Deck

ASC Steel Deck

3W Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 6 1/4” 2 Hour Fire Rating Slab Weight:43.6 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 311 284 261 205 187 171 157 145 133 123 114 106 98 91 852 311 284 261 241 223 171 157 145 133 123 114 106 98 91 85

22 3 311 284 261 241 223 207 193 145 133 123 114 106 98 91 85q3 1676 1664 1654 1644 1636 1628 1621 1615 1609 1603 1598 1594 1589 1586 1582q4 1767 1746 1726 1709 1694 1680 1668 1656 1646 1636 1627 1619 1611 1604 15971 338 309 284 262 206 189 174 160 148 137 127 118 110 102 952 338 309 284 262 242 225 210 160 148 137 127 118 110 102 95

21 3 338 309 284 262 242 225 210 196 184 137 127 118 110 102 95q3 1676 1662 1650 1640 1630 1621 1613 1606 1599 1593 1587 1582 1577 1573 1569q4 1794 1769 1748 1728 1711 1695 1681 1668 1656 1644 1634 1625 1616 1608 16001 352 321 295 272 252 198 182 168 155 144 133 124 115 108 1002 352 321 295 272 252 234 218 168 155 144 133 124 115 108 100

20 3 352 321 295 272 252 234 218 204 191 180 133 124 115 108 100q3 1678 1663 1650 1639 1629 1620 1611 1603 1596 1590 1584 1578 1573 1568 1564q4 1808 1783 1760 1739 1721 1704 1689 1675 1662 1650 1639 1629 1620 1612 16031 396 361 332 306 283 263 245 227 179 166 154 144 134 125 1172 396 361 332 306 283 263 245 230 215 166 154 144 134 125 117

19 3 396 361 332 306 283 263 245 230 215 203 191 181 134 125 117q3 1691 1674 1658 1645 1632 1621 1611 1602 1593 1586 1578 1572 1565 1560 1554q4 1866 1835 1808 1783 1761 1741 1723 1706 1691 1677 1664 1652 1641 1630 16201 426 389 357 329 305 283 264 247 232 181 169 157 147 137 1292 426 389 357 329 305 283 264 247 232 218 206 157 147 137 129

18 3 426 389 357 329 305 283 264 247 232 218 206 194 184 137 129q3 1705 1686 1669 1654 1640 1627 1616 1606 1596 1587 1579 1572 1565 1559 1553q4 1912 1877 1847 1819 1794 1772 1751 1733 1715 1700 1685 1672 1659 1648 16371 494 451 414 382 353 328 306 287 269 253 238 188 176 165 1552 494 451 414 382 353 328 306 287 269 253 238 225 213 202 155

16 3 494 451 414 382 353 328 306 287 269 253 238 225 213 202 192q3 1751 1727 1705 1686 1669 1653 1639 1626 1614 1603 1593 1584 1575 1567 1559q4 2031 1987 1949 1914 1883 1885 1829 1806 1784 1764 1746 1729 1714 1699 1685

Page 33: Floor Deck

Effective June 2009 www.ascsteeldeck.com 33

ASC Steel Deck

3W Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 7 3/16” 3 Hour Fire Rating Slab Weight:52.1 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 363 288 261 237 217 198 182 167 154 143 132 122 114 105 982 363 331 304 280 217 198 182 167 154 143 132 122 114 105 98

22 3 363 331 304 280 259 241 182 167 154 143 132 122 114 105 98q3 1972 1960 1950 1940 1932 1924 1917 1911 1905 1900 1895 1890 1886 1882 1878q4 2063 2042 2023 2006 1990 1976 1964 1952 1942 1932 1923 1915 1907 1900 18931 394 360 330 261 239 219 201 185 171 159 147 136 127 118 1102 394 360 330 304 282 219 201 185 171 159 147 136 127 118 110

21 3 394 360 330 304 282 262 244 228 171 159 147 136 127 118 110q3 1972 1958 1946 1936 1926 1917 1909 1902 1895 1889 1884 1878 1874 1869 1865q4 2090 2065 2044 2024 2007 1991 1977 1964 1952 1941 1930 1921 1912 1904 18971 409 373 343 316 250 229 210 194 179 166 154 143 133 124 1162 409 373 343 316 293 272 210 194 179 166 154 143 133 124 116

20 3 409 373 343 316 293 272 254 237 179 166 154 143 133 124 116q3 1974 1959 1947 1935 1925 1916 1907 1900 1893 1886 1880 1875 1869 1865 1860q4 2105 2079 2056 2035 2017 2000 1985 1971 1958 1947 1936 1926 1916 1908 19001 460 420 385 355 329 306 285 223 207 192 178 166 155 145 1352 460 420 385 355 329 306 285 267 207 192 178 166 155 145 135

19 3 460 429 385 355 329 306 285 267 250 235 178 166 155 145 135q3 1987 1970 1954 1941 1928 1917 1907 1898 1890 1882 1875 1868 1862 1856 1851q4 2163 2132 2104 2079 2057 2037 2019 2002 1987 1973 1960 1948 1937 1926 19171 494 451 414 382 353 328 306 287 225 209 195 182 170 159 1492 494 451 414 382 353 328 306 287 269 209 195 182 170 159 149

18 3 494 451 414 382 353 328 306 287 269 253 238 225 170 159 149q3 2001 1982 1965 1950 1936 1923 1912 1902 1892 1884 1876 1868 1861 1855 1849q4 2208 2174 2143 2115 2090 2068 2047 2029 2012 1996 1981 1968 1955 1944 19331 571 522 479 442 409 380 354 332 311 293 232 216 202 190 1782 571 522 479 442 409 380 354 332 311 293 276 261 202 190 178

16 3 571 522 479 442 409 380 354 332 311 293 276 261 247 234 178q3 2047 2023 2001 1982 1965 1949 1935 1922 1910 1899 1889 1880 1871 1863 1855q4 2327 2284 2245 2210 2179 2151 2125 2102 2080 2061 2040 2025 2010 1995 1982

Page 34: Floor Deck

34 Preformed Metal Floor Deck

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5” Slab Weight: 42.3 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 249 228 209 158 143 131 120 110 101 92 85 78 72 67 602 249 228 209 193 178 131 120 110 101 92 85 78 72 67 60

22 3 249 228 209 193 178 159 141 110 101 92 85 78 72 67 60q3 1605 1594 1583 1574 1565 1557 1550 1544 1538 1533 1528 1523 1519 1515 1511q4 1696 1675 1656 1639 1624 1610 1597 1586 1575 1565 1556 1548 1540 1533 15271 272 248 228 210 159 145 133 122 113 104 96 89 82 76 702 272 248 228 210 194 181 165 122 113 104 96 89 82 76 70

21 3 272 248 228 210 194 181 165 147 131 104 96 89 82 76 70q3 1605 1592 1580 1569 1559 1551 1543 1535 1529 1523 1517 1512 1507 1502 1498q4 1723 1699 1677 1658 1640 1624 1610 1597 1585 1574 1564 1554 1546 1537 15301 283 258 237 218 197 153 140 129 118 109 101 93 87 80 742 283 258 237 218 202 188 175 129 118 109 101 93 87 80 74

20 3 283 258 237 218 202 188 175 157 141 126 101 93 87 80 74q3 1607 1593 1580 1569 1558 1549 1541 1533 1526 1519 1513 1508 1503 1498 1493q4 1738 1712 1689 1669 1650 1633 1618 1604 1592 1580 1569 1559 1550 1541 15331 320 292 268 247 229 213 189 160 138 128 119 110 102 95 892 320 292 268 247 229 213 198 186 174 128 119 110 102 95 89

19 3 320 292 268 247 229 213 198 186 174 156 141 127 102 95 89q3 1620 1603 1588 1574 1562 1551 1541 1531 1523 1515 1508 1501 1495 1489 1484q4 1796 1765 1737 1713 1690 1670 1652 1635 1620 1606 1593 1581 1570 1560 15501 345 315 289 267 247 230 214 192 165 141 131 121 113 105 982 345 315 289 267 247 230 214 200 188 177 160 121 113 105 98

18 3 345 315 289 267 247 230 214 200 188 177 160 145 131 105 98q3 1635 1615 1598 1583 1569 1557 1545 1535 1526 1517 1509 1501 1494 1488 1482q4 1842 1807 1776 1748 1724 1701 1681 1662 1645 1629 1615 1601 1589 1577 15661 403 368 338 312 289 260 233 209 189 170 153 143 131 119 1092 403 368 338 312 289 260 233 209 189 170 153 141 128 116 109

16 3 403 368 338 312 289 260 233 209 189 170 153 141 128 116 105q3 1680 1656 1635 1616 1598 1583 1568 1555 1543 1533 1522 1513 1504 1496 1489q4 1960 1917 1878 1843 1812 1784 1758 1735 1714 1694 1676 1659 1643 1628 1615

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 35: Floor Deck

Effective June 2009 www.ascsteeldeck.com 35

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5 1/2” Slab Weight: 48.3 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 273 249 189 171 155 142 129 118 109 100 92 84 78 72 662 273 249 229 211 155 142 129 118 109 100 92 84 79 72 66

22 3 273 249 229 211 195 181 129 118 109 100 92 84 78 72 66q3 1845 1833 1822 1813 1804 1797 1790 1783 1777 1772 1767 1762 1758 1754 1750q4 1936 1914 1895 1878 1863 1849 1836 1825 1814 1804 1796 1787 1780 1772 17661 297 271 249 229 173 157 144 132 122 112 103 95 88 81 752 297 271 249 229 213 198 144 132 122 112 103 95 88 81 75

21 3 297 271 249 229 213 198 184 168 122 112 103 95 88 81 75q3 1844 1831 1819 1808 1798 1790 1782 1774 1768 1762 1756 1751 1746 1741 1737q4 1962 1938 1916 1897 1879 1864 1849 1836 1824 1813 1803 1793 1785 1777 17691 309 282 259 239 181 165 151 139 128 118 109 101 93 86 802 309 282 259 239 221 205 151 139 128 118 109 101 93 86 80

20 3 309 282 259 239 221 205 192 179 161 118 109 101 93 86 80q3 1846 1832 1819 1808 1797 1788 1780 1772 1765 1755 1752 1747 1742 1737 1732q4 1977 1951 1928 1908 1889 1872 1857 1843 1831 1819 1808 1798 1789 1780 17721 348 318 292 269 249 232 200 162 149 138 128 118 110 102 952 348 318 292 269 249 232 216 202 149 138 128 118 110 102 95

19 3 348 318 292 269 249 232 216 202 190 178 162 118 110 102 95q3 1859 1842 1827 1813 1801 1790 1780 1770 1762 1754 1747 1740 1734 1728 1723q4 2035 2004 1976 1952 1930 1910 1891 1875 1859 1845 1832 1820 1809 1799 17891 375 343 315 290 269 250 233 204 172 151 140 130 121 113 1052 375 343 315 290 269 250 233 218 204 192 140 130 121 113 105

18 3 375 343 315 290 269 250 233 218 204 192 181 168 121 113 105q3 1874 1854 1837 1822 1808 1796 1785 1774 1765 1756 1748 1741 1734 1727 1721q4 2081 2046 2015 1988 1963 1940 1920 1901 1884 1868 1854 1840 1828 1816 18051 437 399 366 338 313 291 271 253 238 217 169 158 147 138 1292 437 399 366 338 313 291 271 253 238 224 211 199 147 138 129

16 3 439 399 366 338 313 291 271 253 238 224 211 199 189 179 164q3 1919 1895 1874 1855 1837 1822 1807 1794 1783 1772 1762 1752 1743 1735 1728q4 2199 2156 2117 2083 2051 2023 1998 1974 1953 1933 1915 1898 1882 1868 1854

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 36: Floor Deck

36 Preformed Metal Floor Deck

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 6 1/2” 1 Hour Fire Rating Slab Weight: 60.5 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 325 247 223 202 183 166 152 139 127 117 107 98 91 83 772 325 296 272 202 183 166 152 139 127 117 107 98 91 83 77

22 3 325 295 272 251 183 166 152 139 127 117 107 98 91 83 77q3 2323 2311 2300 2291 2282 2275 2268 2261 2255 2250 2245 2241 2236 2232 2229q4 2414 2392 2373 2356 2341 2327 2314 2303 2292 2283 2274 2265 2258 2251 22441 353 322 246 223 203 185 169 155 142 131 121 111 103 95 872 353 322 296 273 203 185 169 155 142 131 121 111 103 95 87

21 3 353 322 296 273 253 235 169 155 142 131 121 111 103 95 87q3 2323 2309 2297 2286 2277 2268 2260 2253 2246 2240 2234 2229 2224 2220 2215q4 2440 2416 2394 2375 2357 2342 2327 2314 2302 2291 2281 2272 2263 2255 22471 367 335 307 234 213 194 178 163 150 138 127 117 108 100 932 367 335 307 283 262 194 178 163 150 138 127 117 108 100 93

20 3 367 335 307 283 262 244 227 163 150 138 127 117 108 100 93q3 2324 2310 2297 2286 2276 2266 2258 2250 2243 2237 2231 2225 2220 2215 2211q4 2455 2429 2406 2386 2367 2351 2335 2322 2309 2297 2286 2276 2267 2258 22501 412 377 346 319 295 224 206 189 174 161 149 138 128 119 1102 412 377 346 319 295 274 256 189 174 161 149 138 128 119 110

19 3 412 377 346 319 295 274 256 239 224 161 149 138 128 119 110q3 2337 2320 2305 2291 2279 2268 2258 2249 2240 2232 2225 2218 2212 2206 2201q4 2513 2482 2455 2430 2408 2388 2369 2353 2337 2323 2310 2298 2287 2277 22671 443 405 372 343 317 295 263 207 191 177 164 152 141 131 1222 443 405 372 343 317 295 275 257 191 177 164 152 141 131 122

18 3 443 405 372 343 317 295 275 257 241 227 164 152 141 131 122q3 2352 2333 2316 2300 2286 2274 2263 2252 2243 2234 2226 2219 2212 2205 2199q4 2559 2524 2493 2466 2441 2418 2398 2379 2362 2346 2332 2318 2306 2294 22841 514 469 431 397 368 342 319 298 278 212 197 183 171 159 1492 514 469 431 397 368 342 319 298 278 263 248 183 171 159 149

16 3 514 469 431 397 368 342 319 298 278 263 248 234 222 159 149q3 2398 2373 2352 2333 2315 2300 2286 2273 2261 2250 2240 2230 2222 2214 2206q4 2678 2634 2595 2561 2530 2501 2476 2452 2431 2411 2393 2376 2360 2346 2332

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 37: Floor Deck

Effective June 2009 www.ascsteeldeck.com 37

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 7” 1 1/2 Hour Fire Rating Slab Weight: 66.4 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 298 267 241 218 198 180 164 150 137 126 115 106 97 90 822 352 321 241 218 198 180 164 150 137 126 115 106 97 90 82

22 3 352 321 295 272 198 180 164 150 137 126 115 106 97 90 82q3 2562 2550 2539 2530 2521 2514 2507 2500 2495 2489 2484 2480 2475 2471 2468q4 2653 2631 2612 2595 2580 2566 2554 2542 2531 2522 2513 2504 2497 2490 24831 383 349 266 241 219 200 183 167 154 141 130 120 110 102 942 383 349 321 296 219 200 183 167 154 141 130 120 110 102 94

21 3 383 349 321 296 274 254 183 167 154 141 130 120 110 102 94q3 2562 2548 2536 2525 2516 2507 2499 2492 2485 2479 2473 2468 2463 2459 2454q4 2679 2655 2633 2614 2597 2581 2566 2553 2541 2530 2520 2511 2502 2494 24861 397 363 278 252 230 210 192 176 162 149 137 126 117 108 1002 397 383 333 307 230 210 192 176 162 149 137 126 117 108 100

20 3 397 363 333 307 284 264 192 176 162 149 137 120 117 108 100q3 2563 2549 2536 2525 2516 2505 2497 2489 2482 2476 2470 2464 2459 2454 2450q4 2694 2668 2645 2625 2606 2590 2574 2561 2548 2536 2525 2515 2506 2497 24891 447 408 374 345 320 242 222 204 188 174 161 149 138 128 1192 447 408 374 345 320 297 222 204 188 174 161 149 138 128 119

19 3 447 408 374 345 320 297 277 259 188 174 161 149 138 128 119q3 2577 2559 2544 2530 2518 2507 2497 2488 2479 2471 2464 2457 2451 2446 2440q4 2752 2721 2694 2669 2647 2627 2609 2592 2577 2563 2550 2538 2526 2516 25061 480 438 402 371 343 319 243 223 206 191 176 164 152 141 1322 480 438 402 371 343 319 298 223 206 191 176 164 152 141 132

18 3 480 438 402 371 343 319 298 278 261 246 176 164 152 141 132q3 2591 2572 2555 2539 2526 2513 2502 2491 2482 2473 2465 2458 2451 2444 2438q4 2798 2763 2732 2705 2680 2657 2637 2618 2601 2586 2571 2558 2545 2533 25231 556 507 466 429 397 369 345 322 247 229 212 198 184 172 1602 556 507 466 429 397 369 345 322 302 284 212 198 184 172 160

16 3 556 507 466 429 397 369 345 322 302 284 268 253 184 172 160q3 2637 2613 2591 2572 2555 2539 2525 2512 2500 2489 2479 2469 2461 2453 2445q4 2917 2873 2834 2800 2769 2740 2715 2691 2670 2650 2632 2615 2599 2585 2571

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 38: Floor Deck

38 Preformed Metal Floor Deck

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 7 1/2” 2 Hour Fire Rating Slab Weight: 72.5 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 321 288 260 235 213 194 177 161 148 135 124 114 105 96 882 380 347 260 235 213 194 177 161 148 135 124 114 105 96 88

22 3 380 347 319 235 213 194 177 161 148 135 124 114 105 96 88q3 2801 2789 2778 2769 2761 2753 2746 2739 2734 2728 2723 2719 2714 2710 2707q4 2892 2870 2851 2834 2819 2805 2793 2781 2771 2761 2752 2744 2736 2729 27221 413 318 287 260 236 215 197 180 165 152 140 129 119 110 1012 413 377 346 260 236 215 197 180 165 152 140 129 119 110 101

21 3 413 377 346 319 295 215 197 180 165 152 140 129 119 110 101q3 2801 2787 2775 2764 2755 2746 2738 2731 2724 2718 2712 2707 2702 2698 2694q4 2919 2894 2872 2853 2836 2820 2806 2792 2780 2769 2759 2750 2741 2733 27251 429 391 300 272 247 226 206 189 174 160 147 136 126 116 1072 429 391 359 331 247 226 206 189 174 160 147 136 126 116 107

20 3 429 391 359 331 307 285 206 189 174 160 147 136 126 116 107q3 2802 2788 2775 2764 2754 2744 2736 2728 2721 2715 2709 2703 2698 2693 2689q4 2933 2908 2885 2864 2846 2829 2814 2800 2787 2775 2764 2754 2745 2736 27281 482 440 404 372 285 261 239 220 202 187 173 160 148 137 1282 482 440 404 372 345 261 239 220 202 187 173 160 148 137 128

19 3 482 440 404 372 345 320 299 279 202 187 173 160 148 137 128q3 2816 2798 2783 2769 2757 2746 2736 2727 2718 2710 2703 2697 2690 2685 2679q4 2991 2960 2933 2908 2886 2866 2848 2831 2816 2802 2789 2777 2765 2755 27451 517 473 434 400 370 284 261 240 222 205 190 176 163 152 1412 517 473 434 400 370 344 261 240 222 205 190 176 163 152 141

18 3 517 473 434 400 370 344 321 300 282 205 190 176 163 152 141q3 2830 2811 2794 2778 2765 2752 2741 2731 2721 2712 2704 2697 2690 2683 2677q4 3037 3002 2971 2944 2919 2897 2876 2857 2840 2825 2810 2797 2784 2773 27621 598 546 502 462 428 398 371 347 265 246 228 212 198 185 1722 598 546 502 462 428 398 371 347 326 246 228 212 198 185 172

16 3 598 546 502 462 428 398 371 347 326 306 289 212 198 185 172q3 2876 2852 2830 2811 2794 2778 2764 2751 2739 2728 2718 2709 2700 2692 2684q4 3156 3112 3074 3039 3008 2979 2954 2930 2909 2889 2871 2854 2838 2824 2810

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 39: Floor Deck

Effective June 2009 www.ascsteeldeck.com 39

ASC Steel Deck

3W Composite Floor Deck3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 8 1/4” 3 Hour Fire Rating Slab Weight: 81.6 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 357 320 288 261 236 215 196 179 164 150 138 126 116 107 982 423 320 288 261 236 215 196 179 164 150 138 126 116 107 98

22 3 423 386 288 261 236 215 196 179 164 150 138 126 116 107 98q3 3160 3148 3137 3128 3119 3111 3104 3098 3092 3087 3082 3077 3073 3069 3065q4 3250 3229 3210 3193 3178 3164 3151 3140 3129 3119 3111 3102 3095 3087 30811 393 353 319 289 262 239 218 200 183 169 155 143 132 121 1122 459 419 319 289 262 239 218 200 183 169 155 143 132 121 112

21 3 459 419 385 355 262 239 218 200 183 169 155 143 132 121 112q3 3159 3146 3134 3123 3113 3105 3097 3089 3083 3077 3071 3066 3061 3056 3052q4 3277 3253 3231 3212 3194 3179 3164 3151 3139 3128 3118 3108 3100 3091 30841 477 369 333 302 275 251 229 210 193 177 163 151 139 128 1192 477 435 400 302 275 251 229 210 193 177 163 151 139 128 119

20 3 477 435 400 368 341 251 229 210 193 177 163 151 139 128 119q3 3161 3147 3134 3123 3112 3103 3095 3087 3080 3073 3067 3062 3057 3052 3047q4 3292 3266 3243 3223 3204 3187 3172 3158 3146 3134 3123 3113 3104 3095 30871 536 489 449 347 316 289 265 244 225 207 192 177 164 152 1412 536 489 449 414 316 289 265 244 225 207 192 177 164 152 141

19 3 536 489 449 414 383 356 332 244 225 207 192 177 164 152 141q3 3174 3157 3142 3128 3116 3105 3095 3085 3077 3069 3062 3055 3049 3043 3038q4 3350 3319 3291 3267 3245 3224 3206 3190 3174 3160 3147 3135 3124 3114 31041 575 525 482 445 345 315 290 267 246 227 210 195 181 168 1572 575 525 482 445 412 383 290 267 246 227 210 195 181 168 157

18 3 575 525 482 445 412 383 357 334 246 227 210 195 181 168 157q3 3189 3169 3152 3137 3123 3111 3100 3089 3080 3071 3063 3055 3049 3042 3036q4 3396 3361 3330 3302 3278 3255 3235 3216 3199 3183 3169 3155 3143 3131 31201 665 607 557 514 476 442 412 318 294 272 253 235 219 204 1912 665 607 557 514 476 442 412 386 294 272 253 235 219 204 191

16 3 665 607 557 514 476 442 412 386 362 340 253 235 219 204 191q3 3234 3210 3189 3170 3152 3137 3122 3109 3098 3087 3076 3067 3058 3050 3043q4 3514 3471 3432 3398 3366 3338 3312 3289 3268 3248 3230 3213 3197 3182 3169

1. In shaded areas, mid-span deck shoring required during construction.2. q3 and q4 “q”=allowable diaphragm shear (plf): “3”, “4”=number of welds to support. 3. See pg. 55 for General Notes.

Page 40: Floor Deck

40 Preformed Metal Floor Deck

ASC Steel Deck

3WF Composite Floor Deck4-3/4”

4-3/4”

12”

3”

36”

3 Welds 4 WeldsAlso available in 24” coverage

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

3WF - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20/20 3.44 1.328 0.623 0.62320/18 3.96 1.469 0.634 0.64620/16 4.45 1.585 0.646 0.66618/20 4.10 1.662 0.870 0.83218/18 4.59 1.832 0.885 0.85518/16 5.11 1.984 0.899 0.87316/16 5.73 2.350 1.113 1.080

3WF - Allowable Reactions (plf)Bearing Length

Gauge 1” 1 1/2” 2” 2 1/2” 3” 3 1/2” 4”

20/20275 306 337 367 398 429 459615 666 717 787 867 948 1028

20/18275 306 337 367 398 429 459615 666 717 787 867 948 1028

20/16275 306 337 367 398 429 459615 666 717 787 867 948 1028

18/20602 655 707 760 813 866 9191170 1246 1322 1398 1479 1598 1717

18/18502 655 707 760 813 866 9191170 1246 1322 1398 1479 1598 1717

18/16602 655 707 760 813 866 9191170 1246 1322 1398 1479 1598 1717

16/161042 1117 1193 1268 1344 1419 14951898 1998 2099 2200 2300 2401 2538

1. The top value reflects the allowable reaction at the panel end supports. (prior to concrete cure)2. The bottom value reflects the allowable reaction at the interior supports.

(prior to concrete cure)3. Values are in pounds per linear foot.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5” Slab Weight: 32.0 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20

1 307 280 257 237 220 204 191 178 167 121 112 103 96 89 832 307 280 257 237 220 204 191 178 167 151 112 103 96 89 833 307 280 257 237 220 204 191 178 167 151 148 140 133 89 83q3 1353 1329 1308 1289 1272 1256 1242 1230 1218 1207 1197 1188 1179 1171 1164

20/18

1 309 282 259 239 221 206 192 179 168 121 112 104 97 90 832 309 282 259 239 221 206 192 179 168 158 149 104 97 90 833 309 282 259 239 221 206 192 179 168 158 149 141 134 90 83q3 1408 1380 1354 1331 1310 1292 1275 1259 1245 1232 1220 1209 1199 1189 1180

20/16

1 295 270 247 228 211 196 183 171 161 122 113 105 98 92 862 295 270 247 228 211 196 183 171 161 151 143 105 98 92 863 295 270 247 228 211 196 183 171 161 151 143 135 128 121 86q3 1470 1436 1406 1380 1355 1334 1314 1296 1279 1264 1250 1237 1225 1213 1203

18/20

1 371 339 311 287 265 247 230 215 202 190 179 169 160 123 1162 371 339 311 287 265 247 230 215 202 190 179 169 160 152 1163 371 339 311 287 265 247 230 215 202 190 179 169 160 152 145q3 1389 1362 1338 1316 1297 1279 1263 1249 1235 1223 1212 1201 1191 1182 1174

18/18

1 363 331 304 280 260 241 225 210 197 186 175 165 157 149 1122 363 331 304 280 260 241 225 210 197 186 175 165 157 149 1123 363 331 304 280 260 241 225 210 197 186 175 165 157 149 141q3 1449 1417 1388 1363 1340 1319 1300 1283 1267 1253 1239 1227 1215 1205 1195

18/16

1 350 319 293 270 250 233 217 203 190 179 169 160 151 143 1062 350 319 293 270 250 233 217 203 190 179 169 160 151 143 1063 350 319 293 270 250 233 217 203 190 179 169 160 151 143 136q3 1514 1477 1444 1414 1388 1364 1342 1322 1304 1287 1272 1258 1244 1232 1220

16/16

1 399 364 334 308 285 265 247 231 217 204 193 182 172 163 1552 399 364 334 308 285 265 247 231 217 204 193 182 172 163 1553 399 364 334 308 285 265 247 231 217 204 193 182 172 163 155q3 1559 1519 1483 1451 1422 1396 1372 1351 1331 1312 1296 1280 1266 1252 1240

Page 41: Floor Deck

Effective June 2009 www.ascsteeldeck.com 41

ASC Steel Deck

3WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 5 1/2” 1 Hour Fire Rating Slab Weight: 36.6 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20

1 334 305 280 258 239 222 207 194 150 139 129 120 112 105 982 334 305 280 258 239 222 207 194 182 139 129 120 112 105 983 334 305 280 258 239 222 207 194 182 171 161 152 112 105 98q3 1511 1487 1466 1447 1430 1414 1400 1387 1376 1365 1355 1346 1337 1329 1322

20/18

1 337 307 282 260 241 224 209 195 157 140 130 121 113 106 992 337 307 282 260 241 224 209 195 183 172 130 121 113 106 993 337 307 282 280 241 224 209 195 183 172 163 154 113 106 99q3 1566 1538 1512 1489 1468 1450 1433 1417 1403 1390 1378 1367 1357 1347 1338

20/16

1 338 309 284 262 242 225 210 196 151 140 130 121 113 106 992 338 309 284 262 242 225 210 196 184 173 130 121 113 106 993 338 309 284 262 242 225 210 196 184 173 163 154 146 106 99q3 1628 1594 1564 1538 1513 1492 1472 1454 1437 1422 1408 1395 1383 1371 1361

18/20

1 402 367 337 311 288 267 249 233 219 206 194 183 174 132 1242 402 367 337 311 288 267 249 233 219 206 194 183 174 132 1243 402 367 337 311 288 267 249 233 219 206 194 183 174 155 124q3 1547 1520 1496 1474 1455 1437 1421 1407 1393 1381 1370 1359 1349 1340 1332

18/18

1 406 371 340 314 290 270 252 235 221 208 196 185 175 133 1252 406 371 340 314 290 270 252 235 221 208 196 185 175 133 1253 406 371 340 314 290 270 252 235 221 208 196 185 175 166 158q3 1607 1575 1546 1521 1498 1477 1458 1441 1425 1411 1397 1385 1373 1363 1353

18/16

1 408 373 342 316 292 272 253 237 222 209 197 186 176 134 1262 408 373 342 316 292 272 253 237 222 209 197 186 176 134 1263 408 373 342 316 292 272 253 237 222 209 197 186 176 167 159q3 1672 1635 1602 1572 1546 1522 1500 1480 1462 1445 1430 1416 1402 1390 1378

16/161 473 432 396 365 338 314 293 274 257 242 228 216 204 194 1502 473 432 396 365 338 314 293 274 257 242 228 216 204 194 1843 473 432 396 365 338 314 293 274 257 242 228 216 204 194 184q3 1717 1677 1641 1609 1580 1554 1530 1509 1489 1470 1454 1438 1424 1410 1397

Page 42: Floor Deck

42 Preformed Metal Floor Deck

ASC Steel Deck

3WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)Total Slab Thickness: 6 1/4” 2 Hour Fire Rating Slab Weight: 43.6 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20

1 378 345 316 292 270 251 234 181 168 156 145 135 126 117 1102 378 345 316 292 270 251 234 219 168 156 145 135 126 117 1103 378 345 316 292 270 251 234 219 206 193 182 135 126 117 110q3 1748 1724 1703 1684 1667 1651 1637 1624 1613 1602 1592 1583 1574 1566 1559

20/18

1 380 347 319 294 272 253 236 183 169 157 146 136 126 118 1102 380 347 319 294 272 253 236 221 169 157 146 136 126 118 1103 380 347 319 294 272 253 236 221 207 195 184 136 126 118 110q3 1803 1774 1749 1726 1705 1687 1670 1654 1640 1627 1615 1604 1594 1584 1575

20/16

1 382 349 320 295 273 254 237 183 170 157 146 136 127 118 1102 382 349 320 295 273 254 237 222 208 157 146 136 127 118 1103 382 349 320 295 273 254 237 222 208 196 184 136 127 118 110q3 1865 1831 1801 1775 1750 1729 1709 1691 1674 1659 1645 1632 1619 1608 1598

18/20

1 453 413 379 350 324 301 281 263 246 232 219 169 158 147 1382 453 413 379 350 324 301 281 263 246 232 219 169 158 147 1383 453 413 379 350 324 301 281 263 246 232 219 207 158 147 138q3 1784 1757 1733 1711 1692 1674 1658 1644 1630 1618 1606 1596 1586 1577 1569

18/18

1 457 417 383 353 327 304 283 265 249 234 221 170 159 149 1392 457 417 383 353 327 304 283 265 249 234 221 208 159 149 1393 457 417 383 353 327 304 283 265 249 234 221 208 197 187 178q3 1844 1812 1783 1758 1735 1714 1645 1678 1662 1648 1634 1622 1610 1600 1590

18/16

1 460 420 385 355 329 306 285 267 250 235 222 171 160 149 1402 460 420 385 355 329 306 285 267 250 235 222 210 160 149 1403 460 420 385 355 329 306 285 267 250 235 222 210 199 188 179q3 1909 1872 1839 1809 1783 1759 1737 1717 1699 1682 1667 1653 1639 1627 1615

16/161 530 484 444 410 379 352 329 308 288 271 256 242 229 178 1672 530 484 444 410 379 352 329 308 288 271 256 242 229 217 2063 530 484 444 410 379 352 329 308 288 271 256 242 229 217 206q3 1954 1913 1878 1846 1817 1791 1767 1745 1726 1707 1691 1675 1661 1647 1634

Page 43: Floor Deck

Effective June 2009 www.ascsteeldeck.com 43

ASC Steel Deck

3WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5” Slab Weight: 42.3 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20

1 307 280 257 237 220 204 191 142 131 121 112 103 96 89 832 307 280 257 237 220 204 191 178 131 121 112 103 96 89 833 307 280 257 237 220 204 191 178 167 157 148 103 96 89 83q3 1677 1654 1632 1613 1596 1581 1567 1554 1542 1531 1521 1512 1504 1496 1488

20/18

1 309 282 259 239 221 206 192 142 131 121 112 104 97 90 832 309 282 259 239 221 206 192 179 131 121 112 104 97 90 833 309 282 259 239 221 206 192 179 168 158 149 104 97 90 83q3 1733 1704 1678 1656 1635 1616 1599 1584 1570 1557 1545 1533 1523 1513 1504

20/16

1 295 270 247 228 211 196 183 134 123 114 105 97 90 83 772 295 270 247 228 211 196 183 171 161 114 105 97 90 83 773 295 270 247 228 211 196 183 171 161 151 143 97 90 83 77q3 1794 1761 1731 1704 1680 1658 1638 1620 1604 1588 1574 1561 1549 1538 1527

18/20

1 371 339 311 287 265 247 230 215 202 190 179 132 123 115 1072 371 339 311 287 265 247 230 215 202 190 179 169 123 115 1073 371 339 311 287 265 247 230 215 202 190 179 169 123 115 107q3 1713 1686 1662 1641 1621 1604 1588 1573 1560 1547 1536 1525 1516 1507 1498

18/18

1 363 331 304 280 260 241 225 210 197 186 175 128 119 111 1042 363 331 304 280 260 241 225 210 197 186 175 165 119 111 1043 363 331 304 280 260 241 225 210 197 186 175 165 157 149 141q3 1773 1741 1713 1687 1664 1644 1625 1607 1592 1577 1564 1551 1540 1529 1519

18/16

1 350 319 293 270 250 233 217 203 190 179 169 122 113 105 982 350 319 293 270 250 233 217 203 190 179 169 160 113 105 983 350 319 293 270 250 233 217 203 190 179 169 160 151 143 136q3 1838 1801 1768 1739 1712 1688 1667 1647 1629 1612 1596 1582 1569 1556 1545

16/161 399 364 334 308 285 265 247 231 217 204 193 182 172 125 1172 399 364 334 308 285 265 247 231 217 204 193 182 172 163 1553 399 364 334 308 285 265 247 231 217 204 193 182 172 163 155q3 1883 1843 1807 1775 1746 1720 1697 1675 1655 1637 1620 1604 1590 1577 1564

Page 44: Floor Deck

44 Preformed Metal Floor Deck

ASC Steel Deck

3WF Composite Floor Deck

1. In shaded areas, mid-span deck shoring required during construction.2. q3: “q”=allowable diaphragm shear (plf): “3”=number of welds to support. 3. See pg. 55 for General Notes.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)Total Slab Thickness: 5 1/2” Slab Weight: 48.3 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20

1 334 305 280 258 239 222 166 153 141 130 120 111 103 95 892 334 305 280 258 239 222 207 153 141 130 120 111 103 95 893 334 305 280 258 239 222 207 194 182 171 120 111 103 95 89q3 1917 1893 1871 1852 1835 1820 1806 1793 1781 1770 1760 1751 1743 1735 1727

20/18

1 337 307 282 260 241 224 167 154 142 131 121 112 104 96 892 337 307 282 260 241 224 209 154 142 131 121 112 104 96 893 337 307 282 260 241 224 209 195 183 172 121 112 104 96 89q3 1972 1943 1917 1895 1874 1855 1838 1823 1809 1796 1784 1772 1762 1752 1743

20/16

1 338 309 284 262 242 225 168 154 142 131 121 112 104 96 892 338 309 284 262 242 225 210 196 142 131 121 112 104 96 893 338 309 284 262 242 225 210 196 184 173 121 112 104 96 89q3 2034 2000 1970 1943 1919 1897 1877 1859 1843 1827 1813 1800 1788 1777 1766

18/20

1 402 367 337 311 288 267 249 233 219 206 152 141 132 123 1152 402 367 337 311 288 267 249 233 219 206 152 141 132 123 1153 402 367 337 311 288 267 249 233 219 206 194 141 132 123 115q3 1953 1925 1901 1880 1860 1843 1827 1812 1799 1786 1775 1765 1755 1746 1737

18/18

1 406 371 340 314 290 270 252 235 221 208 154 143 133 124 1162 406 371 340 314 290 270 252 235 221 208 196 143 133 124 1163 406 371 340 314 290 270 252 235 221 208 196 185 175 124 116q3 2012 1980 1952 1926 1903 1883 1864 1847 1831 1816 1803 1790 1779 1768 1758

18/16

1 405 373 342 316 292 272 253 237 222 209 154 144 134 125 1162 405 373 342 316 292 272 253 237 222 209 197 144 134 125 1163 405 373 342 316 292 272 253 237 222 209 197 186 176 167 116q3 2077 2040 2007 1978 1951 1928 1906 1886 1868 1851 1835 1821 1808 1795 1784

16/161 473 432 396 365 338 314 293 274 257 242 228 216 204 150 1412 473 432 396 365 338 314 293 274 257 242 228 216 204 194 1413 473 432 396 365 338 314 293 274 257 242 228 216 204 194 184q3 2122 2082 2046 2014 1985 1959 1936 1914 1894 1876 1859 1844 1829 1816 1803

Page 45: Floor Deck

Effective June 2009 www.ascsteeldeck.com 45

ASC Steel Deck

ASC3 Composite Floor Deck

ASC2 Composite Floor Deck

1. The section properties are based on 38,000 psi yield stress.2. The first number is the gauge or thickness of fluted top sheet. The second number is the gauge or thickness of flat bottom sheet.

1. The section properties are based on 38,000 psi yield stress.2. The first number is the gauge or thickness of fluted top sheet. The second number is the gauge or thickness of flat bottom sheet.

1The first number is the gauge of fluted top sheet. The second number is the gauge of flat bottom sheet.

1The first number is the gauge of fluted top sheet. The second number is the gauge of flat bottom sheet.

2”

4 Welds

24”

FD_8 ASC2

3”

4 Welds

24”

FD_7 ASC3

ASC3 (24”)-Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20/20 3.35 1.339 0.620 0.57020/18 3.86 1.455 0.622 0.59820/16 4.36 1.536 0.628 0.62718/20 3.95 1.664 0.827 0.74418/18 4.45 1.812 0.850 0.77918/16 4.96 1.933 0.868 0.81316/16 5.56 2.293 1.071 0.995

ASC2 (24”)-Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20/20 3.17 0.618 0.411 0.39520/18 3.68 0.674 0.421 0.41520/16 4.18 0.719 0.430 0.43518/20 3.71 0.761 0.576 0.51418/18 4.19 0.835 0.592 0.53918/16 4.71 0.895 0.605 0.56416/16 5.26 1.060 0.746 0.689

ASC3 (24”)-Allowable Reaction (PLF)Bearing Reaction Location

Gauge1 Length End Interior

20/20 2” 285 64820/18 2” 285 64820/16 2” 285 64818/20 2” 537 124518/18 2” 537 124518/16 2” 537 124516/16 2” 998 2020

ASC2 (24”)-Allowable Reaction (PLF)Bearing Reaction Location

Gauge1 Length End Interior

20/20 2” 304 67820/18 2” 304 67820/16 2” 304 67818/20 2” 562 128718/18 2” 562 128718/16 2” 562 128716/16 2” 1035 2076

Page 46: Floor Deck

46 Preformed Metal Floor Deck

ASC Steel Deck

ASC3 Composite Floor DeckAllowable Superimposed Load (psf) for ASC3 (24”) Deck with Concrete Density of 145 pcfConcrete: Total Slab Thickness: 5 1/2” Slab Weight: 53 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 369 327 292 262 236 214 171 155 140 127 116 106 97 88 8120/20 2 369 327 292 262 236 214 171 155 140 127 116 106 97 88 81

3 369 327 292 262 236 214 195 155 140 127 116 106 97 88 811 444 394 351 315 284 258 211 191 173 158 144 132 121 111 102

20/18 2 444 394 351 315 284 258 235 191 173 158 144 132 121 111 1023 444 394 351 315 284 258 235 191 173 158 144 132 121 111 1021 517 458 409 367 331 300 249 226 205 187 171 157 144 133 123

20/16 2 517 458 409 367 331 300 273 226 205 187 171 157 144 133 1233 517 458 409 367 331 300 273 250 205 187 171 157 144 133 1231 387 343 306 275 248 225 205 187 172 134 122 112 102 94 86

18/20 2 387 343 306 275 248 225 205 187 172 134 122 112 102 94 863 387 343 306 275 248 225 205 187 172 159 122 112 102 94 861 456 404 361 324 292 265 241 221 203 187 148 136 125 114 105

18/18 2 456 404 361 324 292 265 241 221 203 187 148 136 125 114 1053 456 404 361 324 292 265 241 221 203 187 148 136 125 114 1051 526 466 415 373 336 305 278 254 234 216 174 160 147 135 125

18/16 2 526 466 415 373 336 305 278 254 234 216 174 160 147 135 1253 526 466 415 373 336 305 278 254 234 216 199 160 147 135 1251 515 457 407 365 330 299 273 249 229 211 195 181 143 132 121

16/16 2 515 457 407 365 330 299 273 249 229 211 195 181 168 132 1213 515 457 407 365 330 299 273 249 229 211 195 181 168 132 121

Allowable Superimposed Load (psf) for ASC3 (24”) Deck with Concrete Density of 145 pcfConcrete: Total Slab Thickness: 6” Slab Weight: 59 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 415 368 328 294 266 214 193 174 158 143 130 119 109 100 9120/20 2 415 368 328 294 266 241 193 174 158 143 130 119 109 100 91

3 415 368 328 294 266 241 193 174 158 143 130 119 109 100 911 498 441 393 353 319 262 236 214 194 177 161 148 135 124 114

20/18 2 498 441 393 353 319 289 236 214 194 177 161 148 135 124 1143 498 441 393 353 319 289 263 214 194 177 161 148 135 124 1141 578 512 457 410 370 308 278 252 230 209 192 176 161 149 137

20/16 2 578 512 457 410 370 335 278 252 230 209 192 176 161 149 1373 578 512 457 410 370 335 306 252 230 209 192 176 161 149 1371 438 388 346 310 280 254 231 212 194 152 139 126 116 106 97

18/20 2 438 388 346 310 280 254 231 212 167 152 139 126 116 106 973 438 388 346 310 280 254 231 212 194 152 139 126 116 106 971 514 455 406 364 329 298 272 249 228 183 167 153 140 129 119

18/18 2 514 455 406 364 329 298 272 249 228 183 167 153 140 129 1193 519 455 406 364 329 298 272 249 228 183 167 153 140 129 1191 590 522 466 418 377 342 312 285 262 214 196 179 165 152 140

18/16 2 590 522 466 418 377 342 312 285 262 214 196 179 165 152 1403 590 522 466 418 377 342 312 285 262 242 196 179 165 152 1401 581 515 459 412 372 337 307 281 258 238 220 204 162 149 137

16/16 2 581 515 459 412 372 337 307 281 258 238 220 204 162 149 1373 581 515 459 412 372 337 307 281 258 238 220 204 162 149 137

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.2. See pg. 55 for General Notes.

Page 47: Floor Deck

Effective June 2009 www.ascsteeldeck.com 47

ASC Steel Deck

ASC3 Composite Floor DeckAllowable Superimposed Load (psf) for ASC3 (24”) Deck with Concrete Density of 145 pcfConcrete: Total Slab Thickness: 7 1/2” Slab Weight: 77 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 559 495 442 361 323 289 261 235 213 194 176 161 147 135 12420/20 2 559 495 442 361 323 289 261 235 213 194 176 161 147 135 124

3 559 495 442 397 323 289 261 235 213 194 176 161 147 135 1241 665 589 525 436 390 350 316 286 260 237 216 198 181 167 153

20/18 2 665 589 525 471 390 350 316 286 260 237 216 198 181 167 1533 665 589 525 471 390 350 316 286 260 237 216 198 181 167 1531 767 680 606 508 455 410 370 336 305 278 255 234 215 198 182

20/16 2 767 680 606 544 455 410 370 336 305 278 255 234 215 198 1823 767 680 606 544 491 410 370 336 305 278 255 234 215 198 1821 596 528 471 423 382 346 280 253 229 209 190 174 159 146 134

18/20 2 596 528 471 423 382 346 280 253 229 209 190 174 159 146 1343 596 528 471 423 382 346 315 253 229 209 190 174 159 146 1341 694 614 548 492 444 403 331 300 272 248 227 208 192 175 161

18/18 2 694 614 548 492 444 403 367 300 272 248 227 208 191 175 1613 694 614 548 492 444 403 367 300 272 248 227 208 191 175 1611 791 701 625 561 506 459 418 347 315 288 263 242 222 205 189

18/16 2 791 701 625 561 506 459 418 347 315 288 263 242 222 205 1893 791 701 625 561 506 459 418 383 315 288 263 242 222 205 1891 789 699 623 560 505 458 417 382 351 287 262 241 221 204 188

16/16 2 789 699 623 560 505 458 417 382 351 287 262 241 221 204 1883 789 699 623 560 505 458 417 382 351 323 262 241 221 204 188

Allowable Superimposed Load (psf) for ASC3 (24”) Deck with Concrete Density of 110 pcfTotal Slab Thickness: 5 1/2” Slab Weight: 42 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 354 313 279 251 226 205 187 171 139 126 115 106 97 89 8220/20 2 354 313 279 251 226 205 187 171 139 126 115 106 97 89 82

3 354 313 279 251 226 205 187 171 157 126 115 106 97 89 821 426 377 336 302 272 247 225 206 170 156 142 131 120 111 102

20/18 2 426 377 336 302 272 247 225 206 189 156 142 131 120 111 1023 426 377 336 302 272 247 225 206 189 174 142 131 120 111 1021 470 416 371 333 301 273 248 227 190 173 159 146 134 124 115

20/16 2 470 416 371 333 301 273 248 227 209 173 159 146 134 124 1153 470 416 371 333 301 273 248 227 209 192 159 146 134 124 1151 369 327 291 261 236 214 195 178 164 151 140 129 102 93 86

18/20 2 369 327 291 261 236 214 195 178 164 151 140 129 102 93 863 369 327 291 261 236 214 195 178 164 151 140 129 102 93 861 422 373 333 299 270 245 223 204 187 173 160 148 119 109 101

18/18 2 422 373 333 299 270 245 223 204 187 173 160 148 119 109 1013 422 373 333 299 270 245 223 204 187 173 160 148 138 109 1011 463 410 366 328 296 269 245 224 206 190 175 163 151 122 112

18/16 2 463 410 366 328 296 269 245 224 206 190 175 163 151 122 1123 463 410 366 328 296 269 245 224 206 190 175 163 151 122 1121 443 393 350 314 284 257 235 215 197 182 168 156 145 135 106

16/16 2 443 393 350 314 284 257 235 215 197 182 168 156 145 135 1263 443 393 350 314 284 257 235 215 197 182 168 156 145 135 126

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.2. See pg. 55 for General Notes.

Page 48: Floor Deck

48 Preformed Metal Floor Deck

ASC Steel Deck

ASC3 Composite Floor Deck

1. “Q” is the allowable diaphragm shear capacity in pounds per linear foot.2. “F” is the flexibility factor.

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.2. See pg. 55 for General Notes.

Allowable Superimposed Load (psf) for ASC3 (24”) Deck with Concrete Density of 110 pcfTotal Slab Depth: 6 1/4” Slab wt. 49 psf

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

1 421 373 332 298 269 244 223 182 165 151 138 126 116 106 9820/20 2 421 373 332 298 269 244 223 182 165 151 138 126 116 106 98

3 421 373 332 298 269 244 223 204 165 151 138 126 116 106 981 504 446 398 357 322 292 266 222 202 184 169 155 142 131 121

20/18 2 504 446 398 357 322 292 266 244 202 184 169 155 142 131 1213 504 446 398 357 322 292 266 244 202 184 169 155 142 131 1211 584 517 462 414 374 339 309 260 237 217 199 183 168 156 144

20/16 2 584 517 462 414 374 339 309 283 237 217 199 183 168 156 1443 584 517 462 414 374 339 309 283 260 217 199 183 168 156 1441 442 391 349 313 283 257 234 214 196 181 167 133 122 112 104

18/20 2 442 391 349 313 283 257 234 214 196 181 145 133 122 112 1043 442 391 349 313 283 257 234 214 196 181 167 133 122 112 1041 518 459 409 367 332 301 274 251 230 212 196 160 147 135 125

18/18 2 518 459 409 367 332 301 274 251 230 212 196 160 147 135 1253 518 459 409 367 332 301 274 251 230 212 196 160 147 135 1251 594 526 469 421 380 345 314 287 264 243 225 186 171 158 146

18/16 2 594 526 469 421 380 345 314 287 264 243 225 186 171 158 1463 594 526 469 421 380 345 314 287 264 243 225 209 171 158 1461 584 517 461 414 373 339 309 282 259 239 221 205 191 155 143

16/16 2 584 517 461 414 373 339 309 282 259 239 221 205 191 178 1433 584 517 461 414 373 339 309 282 259 239 221 205 191 178 166

Diaphragm Shear Capacity for ASC3 (24”) with Concrete Fill (PLF) (110 PCF Concrete)Total Slab Depth: 5 1/2” 110 PCF Concrete

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20Q 1540 1520 1500 1480 1460 1450 1430 1420 1410 1400 1390 1380 1370 1360 1350

F 1.12 1.14 1.15 1.17 1.18 1.19 1.20 1.22 1.23 1.24 1.24 1.25 1.26 1.27 1.28

20/18Q 1640 1600 1580 1550 1530 1510 1490 1470 1450 1440 1430 1410 1400 1390 1380

F 0.91 0.93 0.95 0.96 0.98 0.99 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08

20/16Q 1740 1700 1670 1640 1610 1580 1560 1530 1510 1500 1480 1460 1450 1440 1420

F 0.76 0.78 0.80 0.81 0.83 0.84 0.85 0.87 0.88 0.89 0.90 0.91 0.92 0.93 0.93

18/20Q 1540 1520 1500 1480 1460 1450 1430 1420 1410 1400 1390 1380 1370 1360 1350

F 1.12 1.14 1.15 1.17 1.18 1.19 1.20 1.22 1.23 1.24 1.24 1.25 1.26 1.27 1.28

18/18Q 1640 1600 1580 1550 1530 1510 1490 1470 1450 1440 1430 1410 1400 1390 1380

F 0.91 0.93 0.95 0.96 0.98 0.99 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08

18/16Q 1740 1700 1670 1640 1610 1580 1560 1530 1510 1500 1480 1460 1450 1440 1420

F 0.76 0.78 0.8 0.81 0.83 0.84 0.85 0.87 0.88 0.89 0.90 0.91 0.92 0.93 0.93

16/16Q 1740 1700 1670 1640 1610 1580 1560 1530 1510 1500 1480 1460 1450 1440 1420

F 0.76 0.78 0.80 0.81 0.83 0.84 0.85 0.87 0.88 0.89 0.90 0.91 0.92 0.93 0.93

Page 49: Floor Deck

Effective June 2009 www.ascsteeldeck.com 49

ASC Steel Deck

ASC3 Composite Floor Deck

1. “Q” is the allowable diaphragm shear capacity in pounds per linear foot.2. “F” is the flexibility factor.

Diaphragm Shear Capacity for ASC3 (24”) with Concrete Fill (PLF) (145 PCF Concrete)Total Slab Depth: 6” 145 PCF Concrete

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20 Q 2190 2160 2140 2120 2110 2090 2080 2060 2050 2040 2030 2020 2010 2000 2000F 0.79 0.8 0.81 0.81 0.82 0.83 0.83 0.84 0.84 0.85 0.85 0.85 0.86 0.86 0.86

20/18 Q 2280 2250 2220 2190 2170 2150 2130 2110 2100 2080 2070 2060 2050 2030 2020F 0.65 0.66 0.67 0.68 0.69 0.69 0.70 0.70 0.71 0.71 0.72 0.72 0.73 0.73 0.74

20/16 Q 2390 2350 2310 2280 2250 2220 2200 2180 2160 2140 2120 2110 2090 2080 2070F 0.56 0.57 0.57 0.58 0.59 0.60 0.60 0.61 0.62 0.62 0.63 0.63 0.63 0.64 0.64

18/20 Q 2190 2160 2140 2120 2110 2090 2080 2060 2050 2040 2030 2020 2010 2000 2000F 0.79 0.80 0.81 0.81 0.82 0.83 0.83 0.84 0.84 0.85 0.85 0.85 0.86 0.86 0.86

18/18 Q 2280 2250 2220 2190 2170 2150 2130 2110 2100 2080 2070 2060 2050 2030 2020F 0.65 0.66 0.67 0.68 0.69 0.69 0.70 0.70 0.71 0.71 0.72 0.72 0.73 0.73 0.74

18/16 Q 2390 2350 2310 2280 2250 2220 2200 2180 2160 2140 2120 2110 2090 2080 2070F 0.56 0.57 0.57 0.58 0.59 0.60 0.60 0.61 0.62 0.62 0.63 0.63 0.63 0.64 0.64

16/16 Q 2390 2350 2310 2280 2250 2220 2200 2180 2160 2140 2120 2110 2090 2080 2070F 0.56 0.57 0.57 0.58 0.59 0.60 0.60 0.61 0.62 0.62 0.63 0.63 0.63 0.64 0.64

Diaphragm Shear Capacity for ASC3 (24”) with Concrete Fill (PLF) (145 PCF Concrete)Total Slab Depth: 5 1/2” 145 PCF Concrete

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20 Q 1950 1920 1900 1880 1870 1850 1840 1820 1810 1800 1790 1780 1770 1770 1760F 0.89 0.90 0.91 0.92 0.92 0.93 0.94 0.95 0.95 0.96 0.96 0.97 0.97 0.98 0.98

20/18 Q 2040 2010 1980 1960 1930 1910 1890 1870 1860 1840 1830 1820 1810 1800 1790F 0.73 0.74 0.75 0.76 0.77 0.78 0.79 0.79 0.80 0.81 0.81 0.82 0.82 0.83 0.83

20/16 Q 2150 2110 2070 2040 2010 1990 1960 1940 1920 1990 1880 1870 1850 1840 1830F 0.62 0.63 0.64 0.65 0.66 0.67 0.68 0.68 0.69 0.70 0.70 0.71 0.72 0.72 0.73

18/20 Q 1950 1920 1900 1880 1870 1850 1840 1820 1810 1800 1790 1780 1770 1770 1760F 0.89 0.90 0.91 0.92 0.92 0.93 0.94 0.95 0.95 0.96 0.96 0.97 0.97 0.98 0.98

18/18 Q 2040 2010 1980 1960 1930 1910 1890 1870 1860 1840 1830 1820 1810 1800 1790F 0.73 0.74 0.75 0.76 0.77 0.78 0.79 0.79 0.80 0.81 0.81 0.82 0.82 0.83 0.83

18/16 Q 2150 2110 2070 2040 2010 1990 1960 1940 1920 1900 1880 1870 1850 1840 1830F 0.62 0.63 0.64 0.65 0.66 0.67 0.68 0.68 0.69 0.70 0.70 0.71 0.72 0.72 0.73

16/16 Q 2150 2110 2070 2040 2010 1990 1960 1940 1920 1900 1880 1870 1850 1840 1830F 0.62 0.63 0.64 0.65 0.66 0.67 0.68 0.68 0.69 0.70 0.70 0.71 0.72 0.72 0.73

Diaphragm Shear Capacity for ASC3 (24”) with Concrete Fill (PLF) (110 PCF Concrete)Total Slab Depth: 6 1/4” 110 PCF Concrete

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20 Q 1780 1760 1740 1720 1700 1680 1670 1660 1640 1630 1620 1610 1610 1600 1590F 0.97 0.98 0.99 1.01 1.02 1.02 1.03 1.04 1.05 1.06 1.06 1.07 1.07 1.08 1.09

20/18 Q 1870 1840 1810 1790 1760 1740 1720 1710 1690 1680 1660 1650 1640 1630 1620F 0.79 0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.90 0.91 0.91 0.92

20/16 Q 1980 1940 1900 1870 1840 1820 1790 1770 1750 1730 1720 1700 1690 1670 1660F 0.67 0.68 0.70 0.71 0.72 0.73 0.74 0.75 0.76 0.77 0.77 0.78 0.79 0.79 0.80

18/20 Q 1780 1760 1740 1720 1700 1680 1670 1660 1640 1630 1620 1610 1610 1600 1590F 0.97 0.98 0.99 1.01 1.02 1.02 1.03 1.04 1.05 1.06 1.06 1.07 1,07 1.08 1.09

18/18 Q 1870 1840 1810 1790 1760 1740 1720 1710 1690 1680 1660 1650 1640 1630 1620F 0.79 0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.90 0.91 0.91 0.92

18/16 Q 1980 1940 1900 1870 1840 1820 1790 1770 1750 1730 1720 1700 1690 1670 1660F 0.67 0.68 0.70 0.71 0.72 0.73 0.74 0.75 0.76 0.77 0.77 0.78 0.79 0.79 0.8

16/16 Q 1980 1940 1900 1870 1840 1820 1790 1770 1750 1730 1720 1700 1690 1670 1660F 0.67 0.68 0.70 0.71 0.72 0.73 0.74 0.75 0.76 0.77 0.77 0.78 0.79 0.79 0.80

Page 50: Floor Deck

50 Preformed Metal Floor Deck

ASC Steel Deck

ASC3 Composite Floor Deck

Allowable Shear and Flexibility Factors on Diaphragms using ASC3 (24) Electri-DeckFloor System with Trench Header 1,2,3,4

  Deck Gauge Combination  Allowable  Flexibility Factor5

  Cellular  Noncellular  Diaphragm Shear  FC  FT

20/20 20 thru 16 1670 0.42 0.89 20/18 20 thru 16 1670 0.42 0.89 20/16 20 thru 16 1670 0.42 0.89 18/20 20 thru 16 1670 0.42 0.89 18/18 20 thru 16 1670 0.42 0.89 18/16 20 thru 16 1670 0.42 0.89 16/16 20 thru 16 1670 0.42 0.89 None 20 thru 16 1710 0.42 1.5

1. The first number of the deck gauge is the gauge of the fluted top sheet. Second number is the gauge of the flat bottom sheet2. “Q” is the allowable diaphragm shear capacity in pounds per linear foot.3. “F” is the flexibility factor.

1. Maximum deck span is 12 feet.2. Maximum trench header width is 36 inches.3. Concrete fill is 2-1/2 inches minimum above top of deck flutes.4. FC = Flexibility factor for concrete. FT = Flexibility factor for trench.5. For decks with trench headers, ∆w is equal to the calculated Deflection of the trench added to the Deflection of the concrete outside of the trench.

Diaphragm Shear Capacity for ASC3 (24”) with Concrete Fill (PLF) (145 PCF Concrete)Total Slab Depth: 7 1/2” 145 PCF Concrete

No. ofSpans

Span

Gauge 8’0” 8’6” 9’0” 9’6” 10’0” 10’6” 11’0” 11’6” 12’0” 12’6” 13’0” 13’6” 14’0” 14’6” 15’0”

20/20Q 2910 2880 2860 2840 2820 2810 2790 2780 2770 2760 2750 2740 2730 2720 2710

F 0.59 0.60 0.60 0.61 0.61 0.61 0.62 0.62 0.62 0.63 0.63 0.63 0.63 0.63 0.64

20/18Q 3000 2970 2940 2910 2890 2870 2850 2830 2820 2800 2790 2770 2760 2750 2740

F 0.50 0.50 0.51 0.51 0.52 0.52 0.52 0.53 0.53 0.53 0.53 0.54 0.54 0.54 0.54

20/16Q 3110 3070 3030 3000 2970 2940 2920 2900 2880 2860 2840 2830 2810 2800 2780

F 0.43 0.43 0.44 0.44 0.45 0.45 0.46 0.46 0.46 0.46 0.47 0.47 0.47 0.47 0.48

18/20Q 2910 2880 2860 2840 2820 2810 2790 2780 2770 2760 2750 2740 2730 2720 2710

F 0.59 0.60 0.60 0.61 0.61 0.61 0.62 0.62 0.62 0.63 0.63 0.63 0.63 0.63 0.64

18/18Q 3000 2970 2940 2910 2890 2870 2850 2830 2820 2800 2790 2770 2760 2750 2740

F 0.50 0.50 0.51 0.51 0.52 0.52 0.52 0.53 0.53 0.53 0.53 0.54 0.54 0.54 0.54

18/16Q 3110 3070 3030 3000 2970 2940 2920 2900 2880 2860 2840 2830 2810 2800 2780

F 0.43 0.43 0.44 0.44 0.45 0.45 0.46 0.46 0.46 0.46 0.47 0.47 0.47 0.47 0.48

16/16Q 3110 3070 3030 3000 2970 2940 2920 2900 2880 2860 2840 2830 2810 2800 2780

F 0.43 0.43 0.44 0.44 0.45 0.45 0.46 0.46 0.46 0.46 0.47 0.47 0.47 0.47 0.48

Page 51: Floor Deck

Effective June 2009 www.ascsteeldeck.com 51

ASC Steel Deck

CF 7/8” Concrete Form

1. Stress based on allowable flexural stress of 36 ksi.2. Deflection based on maximum Deflection of L/180.3. Adequate bearing must be provided.

32” Coverage7⁄8”

�22⁄3” CF 7/8-Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

26 1.04 0.027 0.060 0.06024 1.33 0.035 0.078 0.07822 1.62 0.043 0.095 0.09520 1.94 0.051 0.113 0.113

Allowable Total (DL + LL) Uniform Load (psf)

Span CF-7/8 Span (ft)

Condition Gauge 2’0” 2’6” 3’0” 3’6” 4’0” 4’6” 5’0” 5’6” 6’0” 6’6” 7’0

SINGLESPAN

26Stress 360 230 160 118 90 71 58 48 40 34 29

Defl 295 151 87 55 37 26 19 14 11 9 7

24Stress 468 300 208 153 117 92 75 62 52 44 38

Defl 382 196 113 71 48 34 24 18 14 11 9

22Stress 570 365 253 186 143 113 91 75 63 54 47

Defl 470 241 139 88 59 41 30 23 17 14 11

20Stress 678 434 301 221 170 134 108 90 75 64 55

Defl 557 285 165 104 70 49 36 27 21 16 13

DOUBLESPAN

26Stress 360 230 160 118 90 71 58 48 40 34 29

Defl 360 230 160 118 88 62 45 34 26 20 16

24Stress 468 300 208 153 117 92 75 62 52 44 38

Defl 468 300 208 153 115 80 58 44 34 26 21

22Stress 570 365 253 186 143 113 91 75 63 54 47

Defl 570 365 253 186 141 99 72 54 41 32 26

20Stress 678 434 301 221 170 134 108 90 75 64 55

Defl 678 434 301 221 167 117 85 64 49 39 31

TRIPLESPAN

26Stress 450 288 200 147 113 89 72 60 50 43 37

Defl 450 285 164 103 69 48 35 26 20 16 12

24Stress 585 374 260 191 146 116 94 77 65 55 48

Defl 585 369 213 134 90 63 46 34 26 21 16

22Stress 713 456 317 233 189 141 114 94 79 67 58

Defl 713 453 262 165 110 77 56 42 32 25 20

20Stress 848 542 377 277 212 167 136 112 94 80 69

Defl 848 538 311 196 131 92 67 50 38 30 24

Page 52: Floor Deck

52 Preformed Metal Floor Deck

ASC Steel Deck

CF 1 3/8” Concrete Form

1-3/8”

4-9/16”

32”

FD10 CF 1-3/8”

1. Stress based on allowable flexural stress of 36 ksi (for 18 ga. stress based on allowable flexural stress of 22.8 ksi).2. Deflection based on maximum Deflection of L/180.3. Adequate bearing must be provided.

CF 1 3/8 - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

26 1.04 0.072 0.094 0.09424 1.33 0.065 0.131 0.13122 1.62 0.122 0.169 0.16920 1.92 0.146 0.205 0.20518 2.56 0.195 0.263 0.263

CF 1 3/8 Allowable Total (DL + LL) Uniform Load (psf)

Span CF 1 3/8 Span (ft)

Condition Gauge 2’0” 2’6” 3’0” 3’6” 4’0” 4’6” 5’0” 5’6” 6’0” 6’6” 7’0

SINGLESPAN

26Stress 251 184 141 111 90 75 63 53 46 40 35Defl 233 147 98 69 50 38 29 23 18 15 12

24Stress 349 257 197 155 126 104 87 74 64 56 49Defl 317 200 134 94 69 51 40 31 25 20 17

22Stress 451 331 254 200 162 134 113 96 83 72 63Defl 395 249 167 117 85 64 49 39 31 25 21

20Stress 547 402 308 243 197 163 137 116 100 87 77Defl 473 298 199 140 102 77 59 46 37 30 25

18Stress 444 326 249 197 159 132 111 94 81 71 62Defl 444 326 249 187 136 102 79 62 50 40 33

DOUBLESPAN

26Stress 251 184 141 111 90 75 63 53 46 40 35Defl 251 184 141 111 90 75 62 53 44 35 29

24Stress 349 257 197 155 126 104 87 74 64 56 49Defl 349 257 197 155 126 104 87 74 60 48 40

22Stress 451 331 254 200 162 134 113 96 83 72 63Defl 451 331 254 200 162 134 113 93 74 60 50

20Stress 547 402 308 243 197 163 137 116 100 87 77Defl 547 402 308 243 197 163 137 111 89 72 59

18Stress 444 326 249 197 159 132 111 94 81 71 62Defl 444 326 249 197 159 132 111 94 81 71 62

TRIPLESPAN

26Stress 313 230 176 139 113 93 78 67 58 50 44Defl 313 230 176 130 95 71 54 43 34 28 23

24Stress 437 321 246 194 157 130 109 93 80 70 61Defl 437 321 246 177 129 97 74 58 47 38 31

22Stress 563 414 319 250 203 168 141 120 103 90 79Defl 563 414 319 220 160 120 93 73 58 47 39

20Stress 683 502 384 304 246 203 171 146 126 109 96Defl 683 502 376 264 192 144 111 87 70 57 47

18Stress 555 407 312 246 199 165 138 118 101 88 78Defl 555 407 312 246 199 165 138 117 93 76 62

Page 53: Floor Deck

Effective June 2009 www.ascsteeldeck.com 53

ASC Steel Deck

Deep Deck (Form)

9”

6”

12”

FD12 6” Deep Deck (Form)

9”

12”

4-1/2”

FD11 4-1/2” Deep Deck (Form)

1. Loads based on bending stress limit of Fb=20 ksi or Deflection limit of L/240.2. Bearing must be checked using actual loads and bearing lengths.

4 1/2” Deep Deck - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20 2.86 2.44 0.924 0.95718 3.74 3.42 1.266 1.31316 4.69 4.36 1.608 1.63514 5.86 5.49 2.056 2.056

1. Section properties are based on minimum 33 ksi steel (Fy)

6” Deep Deck - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20 3.22 4.79 1.386 1.31418 4.22 6.68 1.892 1.96616 5.29 8.56 2.406 2.45114 6.61 10.78 3.085 3.087

1. Section properties are based on minimum 33 ksi steel (Fy)

4 1/2” Deep Deck Allowable Total (DL + LL) Uniform Load (psf)

Span CF-7/8 Span (ft)

Condition Gauge 10’0” 12’0” 14’0” 16’0” 18’0” 20’0” 22’0” 24’0” 26’0” 28’0” 30’0”

SINGLESPAN

20Stress 123 86 63 48 38 31 25 21 18 16 14

Defl 123 86 58 39 27 20 15 12 9 7 6

18Stress 169 117 86 66 52 42 35 29 25 22 19

Defl 169 117 82 55 38 28 21 16 13 10 8

16Stress 214 149 109 84 66 54 44 37 32 27 24

Defl 214 149 104 70 49 36 27 21 16 13 11

14Stress 274 190 140 107 85 69 57 48 41 35 30

Defl 274 190 131 88 62 45 34 26 20 16 13

6” Deep Deck Allowable Total (DL + LL) Uniform Load (psf)

Span CF-7/8 Span (ft)

Condition Gauge 10’0” 12’0” 14’0” 16’0” 18’0” 20’0” 22’0” 24’0” 26’0” 28’0” 30’0”

SINGLESPAN

20Stress 185 128 94 72 57 46 38 32 27 24 21

Defl 185 128 94 72 54 39 29 23 18 14 12

18Stress 252 175 129 99 78 63 52 44 37 32 28

Defl 252 175 129 99 75 55 41 32 25 20 16

16Stress 321 223 164 125 99 80 66 56 47 41 36

Defl 321 223 164 125 96 70 53 41 32 26 21

14Stress 411 268 210 161 127 103 85 71 61 52 46

Defl 411 286 210 161 121 88 66 51 40 32 26

Page 54: Floor Deck

54 Preformed Metal Floor Deck

ASC Steel Deck

Deep Deck (Form)

FD13 7-1/2” Deep Deck

7-1/2”

9”

12”

1. Loads based on bending stress limit of Fb=20 ksi or Deflection limit of L/240.2. Bearing must be checked using actual loads and bearing lengths.

7 1/2” Deep Deck - Section PropertiesWeight I S+ S--

Gauge (psf) (In4) (In3) (In3)

20 3.59 8.11 1.899 1.6718 4.7 11.28 2.593 2.52816 5.9 14.47 3.3 3.36714 7.38 18.26 4.238 4.245

1. Section properties are based on minimum 33 ksi steel (Fy)

7 1/2” Deep Deck Allowable Total (DL + LL) Uniform Load (psf)

Span CF-7/8 Span (ft)

Condition Gauge 10’0” 12’0” 14’0” 16’0” 18’0” 20’0” 22’0” 24’0” 26’0” 28’0” 30’0”

SINGLESPAN

20Stress 253 176 129 99 78 63 52 44 37 32 28

Defl 253 176 129 99 78 63 50 38 30 24 20

18Stress 346 240 176 135 107 86 71 60 51 44 38

Defl 346 240 176 135 107 86 69 53 42 34 27

16Stress 440 306 224 172 136 110 91 76 65 56 49

Defl 440 306 224 172 136 110 89 69 54 43 35

14Stress 565 392 288 221 174 141 117 98 84 72 63

Defl 565 392 288 221 174 141 112 87 68 55 44

Page 55: Floor Deck

Effective June 2009 www.ascsteeldeck.com 55

ASC Steel Deck

General Notes

The following notes apply to the allowable total load tables and/or to the allowable superimposed load & diaphragm shear tables. 1. Arc spot or arc seam (puddle) welds shall have an

effective fusion area, to supporting members, equivalent to at least 3/8” by 1” long or 1/2” in diameter. 2. Spacing of marginal welds to members parallel to the flutes: (a) Arc spot (puddle) welds to members, such as chords, and to collector elements, such as struts or ties, shall have a spacing in feet equal to 32,000 (t) /v, where: t = Uncoated steel thickness of fluted deck in inches. (see ICC report for “t”) v = Actual diaphragm shear at marginal supports or actual shear transferred to collector (at struts or ties) in pounds per foot. (b) Fillet welds to members, such as diaphragm chords, shall have a spacing in feet equal to 480 Iw/v, where: lw = Length of weld in inches (not less than 1 1/2” v = Actual diaphragm shear to be transferred to chords in pounds per foot. (c) Fillet welds attaching the diaphragm to

struts, ties or other collector elements shall have a spacing, in feet, equal to 300 Iw/v where:

v = Actual diaphragm shear to be transferred to the collector element, in pounds per foot.

(d) In no case shall any weld spacing exceed 3’0”. 3. Attachments at interior lines of shear transfer, perpendicular to deck corrugations: (a) The shear transfer from a diaphragm to interior

ties or strut lines, perpendicular to deck corrugations, shall not exceed the shear values indicated in the tables. Two lines of puddle welds may be used to develop the actual shear transfer to these collector elements.

4. The minimum 28-day compressive strength for structural concrete shall be 3000 psi and the density as indicated in the tables or as required for fire rating. The minimum depth of concrete shall be 2” over the top flange and it is to be reinforced with a minimum 6 x 6 W1.4 x W1.4 welded wire fabric. The reinforcement shall be placed near the center of the fill, over the top flange. If fill exceeds 3 1/4” thick the reinforcement area must equal 0.00075 times the depth of fill over top of deck, each way.

5. All decks with structural concrete fill may be considered rigid diaphragms, f<1.0, unless otherwise noted.

6. Shoring calculations are based on the deck profile supporting the dead load of concrete, plus either:

(a) a 20 psf uniform construction load, or (b) a 150 lb. concentrated live load for flexure. The dead load Deflection is limited to L/180, but not to exceed 3/4”. 7. Total Slab Thickness: is the nominal total slab depth, measured from the bottom flange of the rib to the top of

the concrete. This applies to all allowable superimposed load and diaphragm shear tables. 8. For all cellular profiles, the first number of the gauge designation (20/20) refers to beam section (corrugated

profile). The second number (20/20) refers to the pan section (flat plate).

9. Seam attachment for composite floor deck to be minimum button punch @ 36” O.C.

10. Typical floor deck manufacturing tolerances: Panel length: +/- 1/2” Thickness: Not less than 95% of the design base metal thickness Panel cover width: -3/8”, + 3/4” Panel camber/sweep: 1/4” in 10’ length Panel end out of square: 1/8” per foot of panel width

Page 56: Floor Deck

56 Preformed Metal Floor Deck

ASC Steel Deck

Fire Resistance RatingsFire Resistance Rating-Floor Deck

RestrainedAssembly

Hourly Rating

ULDesign 

No.

Concrete Thickness“(Above Deck)”

Type ProfileFireproofing 

Type

1,1 1/2, 2 & 3 D703 2 1/2” LWT & NWT 2W, 3W, ASC2 & ASC3 Cementitious3 & D708 2 1/2” LWT & NWT B, BF, N, NF, 2W & 3W Cementitious

1, 1 1/2, 2 D712 2 1/2” LWT & NWT N, NF, 2W, ASC2 & ASC3 Cementitious1,1 1/2 & 2 D722 2 1/2” LWT & NWT N, NF, 2W, 3W, ASC2 & ASC 3 Cementitious

1, 1 1/2, 2, 3 & 4 D739 2 1/2” LWT & NWT B, BF, N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3 Cementitious2 D740 2 1/2” NWT B Cementitious

1, 1 1/2, 2 & 3 D743 2” LWT & NWT 2W, 2WF, 3W, 3WF, ASC2 & ASC3 Cementitious3 D753 2 3/4” LWT & NWT CF-7/8 & CF-1 3/8 Cementitious

2 & 3 D755 2 1/2” LWT & NWT B, BF, 2W, 3W, ASC2 & ASC3 Cementitious1, 1 1/2, 2 & 3 D759 2 1/2” LWT & NWT B, 2W, 2WF, 3W, 3WF, ASC2 & ASC3 Cementitious

2, 3 & 4 D760 2 1/2” LWT & NWT B, 2W & 3W Cementitious3 & 4 D754 3 1/4” LWT B, N, 2W & 3W Cementitious

2 D764 2 1/2” LWT B, BF N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3 Cementitious3 D768 2 1/2” LWT & NWT B, BF, N, NF, 2W & 3W Cementitious3 D776 2 3/4” LWT & NWT CF-7/8” & CF-1 3/8” Cementitious

1, 1 1/2, 2 & 3 D780 2 1/2” LWT & NWT CF-7/8” & CF-1 3/8” Cementitious1, 1 1/2, 2, 3 & 4 D782 3 1/4” LWT B, N, 2W & 3W Cementitious

2 D826 3 1/4” LWT B, BF, N, NF, 2W & 3W None1, 1 1/2, 2 & 3 D832 2 1/2” LWT & NWT B, BF, 2W, 3W, ASC2 & ASC3 Fiberous

2 & 3 D833 2 1/2” LWT & NWT 2W Fiberous2 D840 3 1/4” LWT B, BF, N, NF, 2W & 3W None

1, 1 1/2, 2, 3 & 4 D858 2 1/2” LWT & NWT 2W, 3W, ASC2 & ASC3 Fiberous2 D861 2 1/2” LWT & NWT 2W Fiberous3 D863 2 3/4” LWT & NWT CF-7/8 & CF-1 3/8 Fiberous

1, 1 1/2, 2 & 3 D859 2” LWT & NWT 2W, 3W, ASC2 & ASC3 Fiberous1, 1 1/2, 2 & 3 D871 2 1/2” LWT & NWT 2W & 3W Fiberous

2 D756 2 1/2” LWT & NWT ASC2 & ASC3 Cementitious1 2 1/2” LWT1 3 1/2” NWT

1 1/2 3” LWT1 1/2 D902 4” NWT B, BF, N, NF, 2W, 2WF, 3W, 3WF None

2 3 1/4” LWT ASC2 & ASC32 4 1/2” NWT3 4 3/16” LWT3 5 1/4” NWT2 D907 3 1/4” LWT B, BF, N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3 None

3/4 or 1 D914 2 1/2” LWT B, BF, N, NF, 2WF, 3W, 3WF, ASC2 & ASC3 None3/4 or 1 2 1/2” LWT

1 3 1/2” NWT1 1/2 3” LWT1 1/2 D916 4” NWT B, BF, N, NF, 2W, 2WF, 3W, 3WF None

2 D925 3 1/4” LWT ASC2 & ASC32 D927 4 1/2” NWT3 4 3/16” LWT3 5 1/4” NWT1 2 1/2” LWT1 3 1/2” NWT

1 1/2 D918 4” NWT B, BF, N, NF, 2W, 2WF, 3W, 3WF None2 3 1/4” LWT ASC2 & ASC32 4 1/2” NWT3 4 3/16” LWT3 5 1/4” NWT

Page 57: Floor Deck

Effective June 2009 www.ascsteeldeck.com 57

ASC Steel Deck

Fire Resistance Ratings continued

Fire Resistance Rating-Floor DeckRestrainedAssembly

Hourly Rating

ULDesign 

No.

Concrete Thickness“(Above Deck)”

Type ProfileFireproofing 

Type

1 2 1/2” LWT1 3 1/2” NWT

1 1/2 3” LWT1 1/2 D919 4” NWT B, BF, N, NF, 2W, 2WF, 3W, 3WF None

2 D931 3 1/4” LWT ASC2 & ASC32 4 1/2” NWT3 4 3/16” LWT3 5 1/4” NWT2 D920 3 1/4” LWT 2W, 2WF, 3W, 3WF, ASC2 & ASC3 None

3/4 or 1 2 1/2” LWT1 3 1/2” NWT

1 1/2 3” LWT B, BF, N, NF, 2W, 2WF, 3W, 3WF1 1/2 D929 4” NWT ASC2 & ASC3 None

2 3 1/4” LWT2 4 1/2” NWT

Shear Stud Data

Allowable Shear Stud Capacity (KIPS/Stud)

Normal Weight Concrete (145 PCF) Lightweight Concrete (110 PCF)

Profile3/4” Headed Stud

Welded Length (in.)1 Stud

Per Flute2 Studs

Per Flute3 Studs

Per Flute1 Studs

Per Flute2 Studs

Per Flute3 Studs

Per Flute

B-36 Hi Form

3 11.50 9.22 9.54 7.64

3.5 11.50 11.50 9.54 9.54

3.8 or 4.5 11.50 11.50 9.54 9.54

2W-36 (24) 3.5, 3.8, 4.5, 4.8, or 5.0 11.50 11.50 11.50 9.54 9.54 9.54

3W-36 (24)

4.5 9.78 6.91 5.65 8.12 5.74 4.69

4.8 11.50 8.35 6.82 9.54 6.93 5.66

5.0 11.50 9.21 7.52 9.54 7.64 6.24

5.5 11.50 11.50 9.41 9.54 9.54 7.81

1. Based on 3000 psi concrete

2. Based on A.I.S.C. specifications

3. Note: Additional reinforcing steel may be required at composite beams.

Page 58: Floor Deck

58 Preformed Metal Floor Deck

ASC Steel Deck

Concrete Weights and VolumesDepth of Slab Over the Top of the Rib

Description ASC Profile 2 1/2” 3” 3 1/4” 3 1/2” 4” 4 3/16” 4 1/4” 4 1/2”

Cubic YardsPer 100 Sq.Ft. of Area

B-36, BF-36 0.927 1.082 1.159 1.236 1.390 1.448 1.467 1.545ShearVent™ 0.927 1.082 1.159 1.236 1.390 1.448 1.467 1.545

BR-36 1.079 1.233 1.130 1.388 1.542 1.600 1.619 1.6962W, 2WF 1.080 1.235 1.312 1.389 1.543 1.601 1.620 1.6963W, 3WF 1.236 1.389 1.466 1.543 1.698 1.755 1.775 1.852

N-24, NF-24 1.039 1.194 1.271 1.348 1.502 1.560 1.579 1.657NR-24 1.430 1.584 1.661 1.739 1.893 1.951 1.970 2.047CP-32 0.984 1.138 1.215 1.292 1.447 1.505 1.524 1.601CF-7/8 0.907 1.061 1.138 1.215 1.370 1.427 1.447 1.524

CF-1 3/8 0.984 1.138 1.215 1.282 1.447 1.505 1.524 1.601ASC2 (24) 1.035 1.189 1.267 1.343 1.498 1.556 1.575 1.652ASC2 (30) 1.106 1.260 1.337 1.414 1.569 1.627 1.646 1.723ASC3 (24) 1.227 1.382 1.459 1.536 1.690 1.748 1.767 1.845ASC3 (30) 1.321 1.476 1.553 1.630 1.784 1.842 1.861 1.939

LIGHTWEIGHTConcrete(110 Pcf)

Wt. Per Sq.Ft. of Area

B-36, BF-36 27.531 32.135 34.422 36.709 41.283 43.006 43.570 45.887BR-36 32.046 36.620 39.907 41.224 45.797 47.520 48.084 50.371

2W, 2WF 32.076 36.680 39.966 41.253 45.827 47.550 48.114 50.4313W, 3WF 36.079 41.253 43.540 45.827 50.431 52.124 52.716 55.004

N-24, NF-24 30.858 35.462 37.749 40.036 44.609 46.332 46.896 49.213NR-24 42.471 47.045 49.332 51.648 56.222 57.945 58.509 60.796CF-7/8 26.938 31.512 33.799 36.086 40.869 42.382 42.976 45.263

CF-1 3/8 29.225 33.800 36.084 38.372 42.976 44.700 45.263 47.550ASC2 (24) 30.737 35.320 37.611 39.902 44.485 46.204 46.777 49.068ASC2 (30) 32.847 37.431 39.723 42.015 46.599 48.318 48.891 51.183ASC3 (24) 36.448 41.030 43.322 45.613 50.196 51.915 52.487 54.779ASC3 (30) 39.251 43.385 46.127 48.419 53.003 54.722 55.295 57.587

NORMALWEIGHTConcrete(145 Pcf)

Wt. Per Sq.Ft. of Area

B-36, BF-36 36.292 42.360 45.375 48.389 54.419 56.689 57.433 60.487BR-36 42.243 48.222 51.287 54.340 60.369 62.640 63.384 66.398

2W, 2WF 42.282 48.350 51.365 54.379 60.408 62.679 63.423 66.4773W, 3WF 48.389 54.379 57.394 60.408 66.477 68.708 69.491 72.506

N-24, NF-24 40.677 46.754 49.760 52.744 58.803 61.074 61.818 64.872NR-24 55.985 62.014 65.028 68.082 74.111 76.382 77.126 80.140CF-7/8 35.509 41.538 44.553 47.567 53.636 55.867 56.650 59.665

CF-1 3/8 38.524 66.553 47.567 50.582 56.650 58.921 59.665 62.679ASC2 (24) 40.524 46.566 49.587 52.608 58.650 60.916 61.671 64.692ASC2 (30) 43.295 49.336 52.358 55.379 61.421 63.686 64.442 67.463ASC3 (24) 48.053 54.095 57.116 60.137 66.179 63.445 69.199 72.221ASC3 (30) 51.735 57.777 60.798 63.819 69.861 72.126 72.882 75.902

1. Deck Deflection not considered.

2. Placement of concrete is to comply with ACI Manual of Concrete Practice.

Code ApprovalsASC’s steel deck profiles have been evaluated or approved for use by:1. ICC Evaluation Service Report No. 1414 and 2408.2. City of Los Angeles Research Report Nos. 23783 23784 and 25762.3. Factory Mutual

Page 59: Floor Deck

Effective June 2009 www.ascsteeldeck.com 59

ASC Steel Deck

Comments on Extraordinary Conditions

A. Positive Bending Reinforcement The deck profile in a composite slab design is the positive bending reinforcement for the slab and must be expected to last the life of the structure. To ensure the integrity of the structure, ASC Steel Deck recommends specifying ASTM A653, G-60 as the minimally acceptable finish.

B. Parking Structures The following conditions are to be considered when using steel deck in a parking structure. 1. All slabs are to be designed as continuous spans with negative reinforcement placed over each support. Alternatively, the steel deck may be used as a concrete form with reinforcement as required. 2. Additional reinforcing is to be included to minimize cracking caused by temperature differential and to provide load distribution. 3. The minimally acceptable galvanized coating is G-90, as per ASTM A653. 4. In corrosive environments, the top surface of the slab is to be sealed and the bottom surface of the steel deck is to receive a field applied finish paint.

C. Vibratory Load Vibratory Loads, e.g., mechanical equipment and forklifts are detrimental to the mechanical bond between the deck and concrete. Additional reinforcing steel, designed by the structural engineer, may be required.

D. Point Load To determine the required deck type and concrete for a point load condition, an equivalent uniform load for a simple span is calculated. Example: 1. 10’0” Span 2. 400 # Point Load at Mid-Span 3. 50 PSF Uniform Floor Load Determine total equivalent uniform superimposed load. A. Maximum Moment from Point Load: M=PL/4=400(10)/4=1000 ft. Ibs. B. Equivalent Uniform Load: W=M(8) =1000(8) = 80 PSF C. Total Equivalent Superimposed Load: 50 + 80 = 130 PSF * Note: Select deck type, concrete type and thickness with a 130 PSF allowable super- imposed load capacity and span length of 10’0”. Provide distribution steel as required. E. Cantilevers

Steel deck used in a cantilevered condition acts solely as a permanent form. The length of the cantilever may be determined using the section properties of the steel deck profile. Negative reinforcement, designed by the structural engineer, is to be added over the support to prevent cracking of the slab.

F. 1% Venting Steel decking used in composite construction should be vented when the slab may be exposed to water, post construction. The vented steel deck will allow the dissipation of residual water vapor. The venting may be produced using punched hole or vent tabs. Contact ASC for more specific information per the specific profile.

Alternative Fastening Methods For attachment of decking, for methods other than welding, refer to the following technical information: Screwed and Pinned Attachments ICBO Report No. Company 3056 ITW, Buildex Division 3829 Pneutek,Inc. 2197 HILTI Fastening Systems

L2 102

Page 60: Floor Deck

60 Preformed Metal Floor Deck

ASC Steel Deck

SDI Edge Form

 SDI is the Steel Deck Institute, the author of the following table. Slab 

Depth 0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”

4.00 20 20 20 20 18 18 16 14 12 12 12 10 104.25 20 20 20 18 18 16 16 14 12 12 12 10 104.50 20 20 20 18 18 16 16 14 12 12 12 10 104.75 20 20 18 18 16 16 14 14 12 12 10 10 105.00 20 20 18 18 16 16 14 14 12 12 10 105.25 20 18 18 16 16 14 14 12 12 12 10 105.50 20 18 18 16 16 14 14 12 12 12 10 105.75 20 18 16 16 14 14 12 12 12 12 10 106.00 18 18 16 16 14 14 12 12 12 10 10 106.25 18 18 16 14 14 12 12 12 12 10 106.50 18 16 16 14 14 12 12 12 12 10 106.75 18 16 14 14 14 12 12 12 10 10 107.00 16 16 14 14 12 12 12 12 10 10 107.25 16 16 14 14 12 12 12 10 10 107.50 16 14 14 12 12 12 12 10 10 107.75 16 14 14 12 12 12 10 10 10 108.00 14 14 12 12 12 12 10 10 108.25 14 14 12 12 12 10 10 10 108.50 14 12 12 12 12 10 10 108.75 14 12 12 12 12 10 10 109.00 14 12 12 12 10 10 109.25 12 12 12 12 10 10 109.50 12 12 12 10 10 109.75 12 12 12 10 10 1010.00 12 12 10 10 10 1010.25 12 12 10 10 1010.50 12 12 10 10 1010.75 12 10 10 1011.00 12 10 10 1011.25 12 10 1011.50 10 10 1011.75 10 1012.00 10 10

The above Selection Table is based on following criteria:

1. Normal weight concrete (150 pcf).

2. Horizontal and vertical Deflection is limited to 1/4” maximum for concrete dead load

3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf.

4. Pour Stop Selection Table does not consider the effect of the performance, Deflection, or rotation of the pour stop support which may

include both the supporting composite deck and/or the frame.

5. Vertical leg return lip is recommended for type 16 and lighter.

6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only.

7. SDI reserves the right to change any information in this section without notice.

1” Fillet Welds @ 12” O.C.

2” min.

FD14 Edge Form detail

Overhang

PourStop

SlabDepth

1/2”

min.

Edge Form Detail

Page 61: Floor Deck

Effective June 2009 www.ascsteeldeck.com 61

ASC Steel Deck

Floor Deck Accessories and Standard Details

Profile Closures

Small Void

Large Void

FD15 Steel Closures

1”

1-1/2”

FD17 “Z” Closure

Varies(Based on

deck height)

“Z” Closure

FD20 Edge Form at the Parallel Condition

FD21 Filler Plate

FD22 Edge Form at the Perpendicular Condition

FD24 Cell ClosureFD23 Stud Locations

1/2”

Varies(Based on

Slab Height)

Varies (Based on Gauge)

FD18 Edge Form

Edge Form

1”

Varies (Based on deck

height)

FD19 Cell Closure

Cell Closure

Varies Not to exceed 8”

(clear span)

FD16 Filler Plate

1”

1”

Filler PlateProfile Closures

Curved Weld Washers Raised Edge Weld Washer

“Z” Closure

Stud Locations Cell Closure

Edge Form Cell Closure

Edge From at the Parallel Condition Filler PlateEdge From at the Perpendicular Condition

Filler Plate

14 gauge X 3/8” dia. hole for welded attachment of CF 7/8”.Curved Weld Washer

14 gauge x 3/8” dia. hole for welded attachment of CF 7/8”

14 gauge x 3/8” dia. hole for welded attachment of CF 1 3/8””

14 gauge X 3/8” dia. hole for welded attachment of CF 1-3/8”

3/4” 1”

Raised Edge Weld Washer

Recommended for 16 ga. and lighter.

Page 62: Floor Deck

62 Preformed Metal Floor Deck

ASC Steel Deck

Composite Floor Deck Specifications

Part l-General 1.01 Work Included A. Furnish all materials and labor necessary to complete metal decking installation per the Contract Documents.

1.02 Related Work, Specified Elsewhere A. The work of this Section shall be closely coordinated with that of Section 05100-Structural Steel Framing; Section 05200-Steel Joists.

1.03 Reference Standards for Quality Assurance A. Codes/Standards- The work and materials of this section shall comply with: 1. Section properties shall be derived in accordance with AISI “Specification for Design of Cold-Formed Steel Structural Members, Latest Edition.” 2. Metal decking is to be attached to the structural frame in conformance with AWS D1.1 and D1.3 “Specification for Welding Sheet Steel in Structures.” 3. ICC Evaluation Service Report No. 1414 and 2408 * Note to Specifier: Insert the appropriate L.A. City Research Report No. when applicable, 23783, 23784, 25762 4. ASTM reference numbers: (a) ASTM A653, Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron alloy-coated (Galvannealed) By The Hot-Dip Process, Structural (Physical) Quality. 5. Steel Deck Institute (SDI)-Metal floor deck profiles shall be in conformance with SDI standards.

1.04 Submittals A. Shop Drawings 1. Prior to fabrication; prepare shop drawings for work under this section and submit to Architect. Shop drawings are to include deck layout, fram- ing and support of openings, layout and quality of studs on beams, dimensions and sections, details of accessories and type and location of welds. 2. Manufacturer’s product literature and relevant approvals are to be submitted with the shop drawings. 3. Where metal decking is part of a fire rated assembly, the metal deck manufacturer shall provide all data to insure compliance with the UL design number and with ICG.

1.05 Product HandlingA. Metal deck Transport, store and erect metal deck and its accessories in a manner that will prevent corrosion, deformation or other damage. Store deck clear of the ground with one end elevated to promote drainage; protect metal deck from water and the elements with a water resistant material. Do not use as a storage platform.

Part 2 - Products2.01 Materials and Finishes A. Metal floor deck to be ASC Steel Deck [select appropriate profile(s) and gauge(s).] 1. B-36, (22,20,18,16) gauge, 1 1/2” deep x 36” wide. 2. N-24 (22,20,18,16) gauge, 3” deep x 24” wide. 3. 2W-36 (22,21,20,19,18,16) gauge, 2 1/8” deep x 36”wide. 4. 3W-36 (22,21,20,19,18,16) gauge, 3” deep x 36”wide. 5. ASC2 or ASC3 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16, 16/16, 3” deep x 24” wide. 6. BF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16, 16/16) gauge; 1 1/2” deep x 36” wide. 7. NF-24 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16, 16/16) gauge; 3” deep x 24” wide. 8. 2WF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16, 16/16)gauge; 2 1/8” deep x 36” wide. 9. 3WF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16, 16/16) gauge; 3” deep x 36” wide. Deck units are to be fabricated from sheet steel conforming to ASTM A653, Fy = 38 KSI with a galvanized coating, (select appropriate coating) G-60, G-90. *Note to Specifier: 2W-36, 3W-36, 2WF-36 and 3WF-36 are available in 24” wide panels; when specified, the designations are 2W-24, 3W-24, 2WF-24 and 3WF-24. *Note to Specifier: When specifying CF-1/2, CF-7/8 or CF-1 3/8, use the following: 1. CF-7/8 (26,24,22,20) gauge, 7/8” deep. 2. CF-1 3/8 (26,24,22,20,18) gauge, 1 3/8” deep. Deck units are to fabricated from sheet steel conforming to ASTM A653, Structural Grade E (26, 24, 22, 20 ga) with a galvanized coating, G-90. CF 1 3/8” (18 ga) is to be fabricated from sheet steel conforming to ASTM A653, Fy = 38 KSI with a galvanized coating, G-90.*Note to Specifier: When specifying Deep Deck, use the following: 1. Deep Deck (20, 18, 16, 14) gauge; 4 1/2”, 6” or 7 1/2” deep deck x 12” wide.Deck units are to be fabricated from sheet steel conforming to ASTM A653, Fy=33KSI with a galvanized coating.

Page 63: Floor Deck

Effective June 2009 www.ascsteeldeck.com 63

ASC Steel Deck

Composite Floor Deck Specifications

2.02 Fabrication A. Metal Deck Manufacture deck units to lengths as indicated on shop drawings. Panel end conditions are to be butted. Sidelaps are to be male/female interlocking type, suitable for button punching. *Note to specifier: When specifying CF-7/8 or CF-1 3/8 delete the last sentence and insert: Sidelaps are to be overlapping type. B. Accessories Fabricate steel deck accessories from the same gauge and material as adjacent steel deck.

Part 3 - Execution 3.01 Inspection A. Examine the areas and conditions under which the work of this Section is to be performed. Correct any conditions which are detrimental to the timely and proper completion of the work of this Section. Do not proceed with work until unsatisfactory conditions are corrected. The General Contractor shall be responsible for obtaining coupons, randomly selected from the steel deck delivered to the job site. These coupons shall be tested by an independent lab to verify that the base metal thickness is within 95% of the deck manufacturer’s published design “t”.

3.02 Installation A. General Install the metal deck and accessories in compliance with the manufacturer’s written recommendations and approved shop drawings. B. Placing Metal Deck Units. Place metal deck units on supporting members and adjust to proper position. Ensure proper bearing on

supporting members and accurate alignment of end- laps and sidelaps prior to permanently attaching units. C. Attachment of Metal Deck Units Welded attachment of metal deck units to the supporting members shall conform to AWS D1.1 and D1.3.

Welders shall be certified prior to commencing work. Attach metal deck units to supporting members with 1/2” effective diameter puddle welds. * Note to Specifier: When specifying CF-7/8 or CF-1 3/8 (24 and 26 gauges only) delete the second paragraph and insert:

Attach metal deck units to supporting members with plug welds using a 14-gauge weld washer having a 3/8” diameter hole and (when attachment method requires) a 16-gauge anchor washer having a 7/16” diameter hole. Welds to supporting members and the method of sidelap attach-ment are to be as per the structural drawings.

Page 64: Floor Deck

64 Preformed Metal Floor Deck

ASC Steel Deck

Materials and Finishes

Metric Conversion ChartMetric Conversions

Multiply  By  To Obtain

  Spans, Length and Thickness Inches 25.4 Millimetres Feet 304.8 Millimetres Inches 0.0254 Metres Feet 0.3048 Metres Vertical Load and Superimposed Load psf 0.0479 kPa psi 6.8948 kPa Area Square feet 0.0929 Square Metre Square 9.2903 Square Metre Diaphragm Shear plf 0.0146 KN/m Section Properties in3/ft 53,763 mm3/m in4/ft 1,365,588 mm4/m in3/ft 53.763 cm3/m in4/ft 136.559 cm4/m Weight Pounds 0.00445 kN psf 4.8824 kg/m2

Volume pcf 16.018 kg/m3

The B, N, 2W, 2WF, ASC2, ASC3, 3W and 3WF profiles are manufactured from steel conforming to ASTM A653 (Fy=38ksi). CF profiles are manufactured from steel conforming to ASTM A653 (Grade E), except CF 1 3/8 (18 ga) which is manufactured from steel conforming to ASTM A653 (Fy=38ksi). The standard galvanized coatings are G-60 (.60 oz./ft2) or G-90 (.90 oz./ft.2) in accordance with ASTM A653. The B, 2W, 2WF, 3W, 3WF ASC2 & ASC3 are available in G-60 and G-90. The CF profiles are available in G-90. Please inquire for the availability of alternate coatings.

Please Note: spot weld discoloration will not be a reason for rejection of cellular deck.

The cellular decking listed in this catalog is manufac-tured from two sections of galvanized steel that are joined with resistance welds. The deck coating and finish will be removed, from the area of the resistance weld, during this process. This condition should be considered when determining the fitness of this product for a specific application. This condition will also not be an acceptable cause for rejection of the material. Please contact your ASC Steel Deck representative for additional information on this subject.

ASC Steel Deck reserves the right to make revisions in the design and/or specifications of our products without prior notice. Dimensions and specifications of products are subject to normal manufacturing tolerances. Consult factory concerning availability of product.

The information in this brochure is, to the best of our knowledge, accurate. However, no information, representation nor formula contained herein is designed to replace the judge-ment of an experienced structural engineer or other professional designer. ASC Steel Deck assumes no liability whatsoever for the accuracy or completeness of the information contained in this brochure, nor for the suitability of the material for its intended purpose.

ASC Steel Deck1-800-726-2727


Recommended