24
Florida Home Inspector License # HI231 Termite/WDO Inspections Champaigne Pest Lic#JB5994 Mold & Air Quality Testing NACHI Certified #07062511 IAC2-01-2776 www.shockleyhomeinspections.com [email protected]
Transcript
  • Florida Home Inspector License # HI231

    Termite/WDO Inspections Champaigne Pest Lic#JB5994

    Mold & Air Quality Testing

    NACHI Certified #07062511

    IAC2-01-2776

    www.shockleyhomeinspections.com

    [email protected]

    http://www.shockleyhomeinspections.com/mailto:[email protected]

  • This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that you carefully read ALL of this information. This inspection is subject to the Standards of Practice for the International Association of Real Estate Inspectors (Nachi), which can be found at www.nachi.org/sop. The Standards of Practice are the minimum standards for inspections by Real Estate Inspectors. An Inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically noted as being inspected were inspected. The inspector is not required to move furnishings or stored items. The inspection report may address issues that are code or building standards-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer’s installation instructions. The inspection does NOT imply insurability or warrant ability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards. This inspection report SHALL NOT constitute a warranty, you should purchase a comprehensive HOME WARRANTY if *FUTURE* occurrences with your home are of concern.

    ITEMS IDENTIFIED IN THE REPORT DO NOT OBLIGATE ANY PARTY TO MAKE REPAIRS OR

    TAKE OTHER ACTIONS, NOR IS THE PURCHASER REQUIRED TO REQUEST THAT THE

    SELLER TAKE ANY ACTION. When a deficiency is reported, it is the client’s responsibility to obtain

    Further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should

    Take place prior to the expiration of any time limitations such as option periods. Evaluations by qualified

    Tradesmen may lead to the discovery of additional deficiencies which may involve additional repair

    costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the

    structure or systems and add to the original repair costs. The inspector is not required to provide follow-

    up services to verify that proper repairs have been made.

    Property conditions change with time and use. For example, mechanical devices can fail at any time,

    plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks

    can occur at any time regardless of the apparent condition of the roof, and the performance of the

    structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These

    changes or repairs made to the structure after the inspection may render information contained herein

    obsolete or invalid. This report is provided for the specific benefit of the client named above and is based

    on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this

    report may provide incomplete or outdated information. Repairs, professional opinions or additional

    inspection reports may affect the meaning of the information in this report. It is recommended that you

    hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with

    current information concerning this property.

    NOTICE: THIS REPORT IS PAID FOR BY AND PREPARED FOR THE CLIENT

    NAMED BELOW. THIS REPORT IS NOT VALID WITHOUT THE SIGNED INSPECTION AGREEMENT

    AND IS NOT TRANSFERABLE.

  • Home Inspection Report

    Four Point Inspection Included

    Property: 1234 Jones street Orlando Florida

    Client: Mr. Smith

    Built: 1961

    Structure: Concrete Block on slab/wood framed

    Roof Structure: wood framed

    State of occupancy: occupied/furnished

    Weather Conditions: cloudy 55 Degrees

    Style: Single Family

    Inspection Date: 1/11/11

    Real Estate Professional: DIDEM ISIK-WIDENER

    A termite inspection was conducted at this property.

    Air quality was tested at this property.

    Definitions

    Satisfactory- indicates the component is functionally consistent with its original purpose

    but may show signs of normal wear and tear and deterioration.

    Marginal- Indicates the component will probably require repair or replacement anytime

    within five years.

    Poor- Indicates the component will need repair or replacement now or in the very near

    future.

  • Date of inspection: 1/1/11

    Property’s Address: 1234 Jones Street

    Property’s City, State, Zip

    Code: Orlando Florida

    Type of home: Single Family

    Type of construction: Block/wood framed

    Type of foundation: Crawlspace

    Number of stories: One

    Approximate square feet: 2000

    Approximate total living

    area: 2000

    Approximate age of home: 1961

    Client/owner’s name: Mr. Smith

    Insurance company/policy

    number: Unknown

    Inspector’s name: David Shockley

    NACHI ID number: 07062511

    Inspector’s signature: David Shockley

    Inspector’s company name: Shockley Home Inspections

    Inspector’s address: 4219 Flora Vista Drive

    Inspector’s city, state, zip

    code: Orlando Florida 32837

    Inspector’s email address: [email protected]

    Inspector’s phone number: 321-287-6007

  • Roof

  • This home has a gable roof covered with rolled asphalt. The

    exact age of the roof covering is not known. The roof was

    inspected from the ground with binoculars, with a ladder at

    the eaves, and on the roof surface. 75% of the roof surface

    was inspected due to debris covering portions of the surface.

    The roof is vented with soffit only; recommend additional

    ventilation. The soffit has been painted clogging many of the

    small vent holes.

  • Roof style: Gable

    Type of roof covering: Rolled Asphalt

    Estimated age of roof

    covering 10 years

    Number of shingle layers: One

    Type of sheathing: Not Visible no access to attic

    Flashing damage noticed? No

    Missing shingles or

    covering? No

    Truss or rafter damage

    noticed? No

    Evidence of active leaks? No

    Estimated life expectancy: 10 Years

    Roof comments:

    Small areas of alligatoring. See photos.

    Large tree branches hanging over the

    house.

    Plumbing

  • Number of bathrooms: 2.5

    Overall water pressure: Satisfactory except in kitchen

    Main supply line material: Copper/plastic

    Main waste/vent material: Plastic/cast iron

    Fixture supply line material: Copper/Flex pipe

    Fixture drain line material: Plastic

    Shut off valves present: Yes

    Water heater location? Laundry Room

    Water heater fuel type? Electric

    Approximate age of water

    heater: 1993

    TPR valve present? Yes

    Fire sprinkler system present? No

    Freeze hazards noticed? No

    Polybutylene noticed? No

    Plumbing leaks noticed? No

    Recent plumbing upgrades?

    Year? NO

    Overall plumbing condition: Satisfactory

    Plumbing comments: Hot water heater is rusted at the base.

    One of the hose bibs is broken.

  • Heating/Air Conditioning

  • Types of heating systems: Two Heat Pumps

    Estimated age of heating

    systems: 2002

    Heating systems upgraded?

    Year? 2002

    Condition of heating

    systems: Tested in air conditioning mode only

    Fuel Tank located? N/A

    Heating system comments: Tested in A/C mode only

    Types of cooling systems: Two heat pumps

    Estimated age of cooling

    systems: 2002

    Cooling systems upgraded?

    Year? 2002

    Condition of cooling

    system: Marginal

    Cooling system comments: See Below

    Both condenser units have oversized breakers installed. This home is equipped with a Two Payne heat pump forced air (also

    provides heat) air conditioning systems installed in 2002. The seer

    rating (seasonal energy efficiency rating is not known). There is

    some dissimilar metal corrosion on the air handler coils. The

    systems are in marginal physical and operating condition. The

    temperature splits for both systems at the time of inspection was less

    than 14 degrees. We recommend having these systems serviced by a

    licensed hvac technician.

    Please note: The temperature split is the difference in the air intake and the return air temperature. Example: If the air temperature in

    to the air handler is 80 degrees and the return temperature

    throughout the house are 66 degrees (80-66=14) the temperature split

    would be 14. The split has to be 14 or greater for the system to be in

    satisfactory operating condition.

  • Electrical

  • Anti oxidant paste missing on the stranded aluminum lines.

    This paste prevents the aluminum from oxidizing.

    Ungrounded two pronged outlets in this home. Both exterior outlets do not operate. The Jacuzzi tub in the master bathroom is not on an isolated

    gfci (ground fault) breaker.

    Some of the ground fault outlets do not trip. I have observed a Federal Pacific “Stab Lok” service panel in the

    house. This panel is a latent fire hazard: its circuit breakers

    may fail to trip in response to an over current or a short

    circuit. Failure of a circuit breaker to trip can result in a

    fire, property damage, or personal injury. A circuit breaker

    that may not trip does not afford the protection that is

    intended and required. Simply replacing the circuit breakers

    is not a reliable repair. The panel and the breakers should be

    replaced. Additional information about the fire and shock

    hazards associated with this equipment can be researched on

    the internet.

    Breakers in the FPE panel are not properly labeled. We recommend that a licensed electrician evaluate the entire

    electrical system in this home.

  • Areas of concern

    Several typical stucco cracks. We recommend patching and

    painting these areas.

    Driveway is in poor condition.

    Gutters are clogged. Trim on the right side of the house has separated.

  • Some of the thin pavers are missing on the front walk.

    Uneven surface (trip hazard) where the driveway and front walk meet.

    Minor window screen damage. Some of the soffit is loose over the garage door.

    Garage door does not sit plumb when closed. Wood decay at the base of one of the front support posts.

  • Garage service door and door casing have wood decay at

    the base.

    Some of the air condition return vents are rusted. Surface mold on the ducts over both air handlers.

    Some of the window screens are missing. Caulking needed in several areas of the bathrooms.

  • Several cracked floor tiles in the den.

    Several areas above the crown molding need to be re-caulked.

    Several of the upper and lower locks on the French Doors do not operate.

  • Tile cracked on the front of the master bathroom tub.

    Sidewalk is cracked.

    Evidence of water collecting on the floor of the garage. Recommend sealing the ceiling areas above the air handlers

    in both closets.

    We recommend that a qualified contractor evaluate the supports and floor joists under the back side of the home. The

    joists have been covered with additional beams and are not

    visible. This was most likely done to level the floors.

  • Homeowner’s Information

    Appliances present: dishwasher, refrigerator, oven, washer,

    dryer, and disposal. All appliances are in satisfactory physical

    and operating condition.

    Electric garage door opener installed : Yes Remote Available : no

  • Main water shut off: Front yard Visible Plumbing pipes: Plastic/copper Water Pressure: satisfactory except in kitchen Gas shut off/meter: N/A Gas appliances: None Electrical service: Underground Main breaker size: 200 amp Panel type and manufacturer: General electric Branch wiring: 15 and 20 amp breakers. main lines: aluminum Appears grounded. Yes arc fault (AFCI) breakers present in bedrooms: no

    Ground fault (GFCI) protection present on all kitchen, bathroom, and exterior outlets. Not outside.

    Main electrical shut off: right side of the house.

    The Jacuzzi tub in the master bathroom is in satisfactory operating

    condition. The access panel to the motor is inside the cabinets to

    the right. The tub is not installed on a ground fault (GFCI) outlet

    which is required by current standards. The outlet is not secured

    to the wall and laying in insulation.

  • Items Not Inspected

    Only 5% of the crawlspace was inspected due to limited access by design. Recommend further evaluation by a qualified

    contractor.

    Air conditioning ducts. Smoke detectors Carbon monoxide detectors (if present). Emergency lighting (if present). Alarm system (if present). Lawn sprinklers (if present). Attic no access. Portions of the garage floors and walls due to stored items. Floors and walls of closets due to stored items.

  • Please contact us if you have any further questions.

    Home inspectors are not required to report on the following: Life expectancy of any component or system; The

    causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for

    any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or

    restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of

    the property; Any component or system that was not observed; The presence or absence of pests such as wood

    damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed.

    Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or

    efficiency of any system or component; Enter any area or perform any procedure that may damage the property or

    its components or be dangerous to the home inspector or other persons; Operate any system or component that is

    shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating

    controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris

    that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental

    condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the

    building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove

    suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since

    this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a

    licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning

    this property. The parties agree and understand that the Inspector David Shockley assume no liability or

    responsibility for the costs of repairing or replacing any unreported defects or deficiencies either current or arising in

    the future or any property damage, consequential damage or bodily injury of any nature. If repairs or replacement

    are done without giving the Inspector the required notice, the Inspector will have no liability to the client. The

    Client further agrees that the Inspector is liable only up to the cost of the inspection.

    Thank you for your business.


Recommended