1 Karsten Litfin, FR09, 08.12.2009 KIT – die Kooperation von Forschungszentrum Karlsruhe GmbH und Universität Karlsruhe (TH) KArlsruhe Liquid metal LAboratory KALLA Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment K. Litfin , A. Batta, A. G. Class,T. Wetzel, R. Stieglitz Karlsruhe Institute of Technology Institute for Nuclear and Energy Technologies [email protected]
Transcript
  • 1 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Flow distribution and turbulent heat transfer in ahexagonal rod bundle experiment

    K. Litfin, A. Batta, A. G. Class,T. Wetzel, R. Stieglitz

    Karlsruhe Institute of TechnologyInstitute for Nuclear and Energy Technologies

    [email protected]

  • 2 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Introduction Liquid metal cooled reactors (ADS)Motivation• Minimization of radiotoxicity of long lived

    fission products (Am,Cu,Np,..)

    Realisation options• Accelerator Driven Systems• Fast critical reactors

    Heavy liquid metal (Pb or LBE) as coolant• High neutron production rate• low reactivity

    Open issues• Turbulent liquid heat transfer of HLM

    along fuel pins and bundles

    Sketch of ADS

  • 3 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Experimental overview:Experimental campaign at KALLA in the framework of IP-EUROTRANS:• LBE single rod experiment

    • Heat transfer for forced, mixed and buoyant convection• Test of heater performance• Validation and qualification of measurement techniques

    • Water rod bundle experiment• Pressure drop in subchannels / rod bundle area• Fluid-structure-interaction (flow induced vibrations)• Validation and qualification of measurement techniques• 2dim flow distribution in sub channels (turbulent mixing)

    • LBE rod bundle experiment• Pressure drop in subchannels / rod bundle area• Temperature distribution of the rod bundle in the forced convection regime• Heat transfer of the hexagonal rod bundle geometry

  • 4 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    ADS Fuel assembly design

    FootHead

    Flow equilizer & straightenerTest section

    FootUpper plenum

    InletFuel pin

    85 112136

    1045993144

    102148146

    122

    114

    10394

    101147

    145

    1116686137

    123 121

    113

    168 167

    153185

    1 5 5

    1 5 6

    1 7 3

    1 7 7 1 6 1

    1 6 2

    1 8 3

    1 8 260 65

    70

    88

    89

    106105 1 5 7

    66

    108107 1 5 8

    67

    110109 1 5 9

    68

    69

    116115

    1 6 3

    71

    118117

    1 6 4

    72

    120119

    1 6 5

    73

    7475124

    125

    16976

    126127

    17077

    128129

    1717879

    130131

    1 7 4

    80

    132133

    1 7 5

    81

    134135

    1 7 6

    82

    83

    1381391 7 9

    84

    1401411 8 0

    1421431 8 1

    87

    86

    85

    64

    150

    96

    149

    186

    98

    56

    97

    151

    100

    58

    99

    15263

    40

    629190

    7170

    7372

    47

    48

    3837

    7574

    27

    49

    4039

    7776

    28

    50

    4241

    7978

    29

    51

    3433

    3635

    1312

    1514

    12

    13

    43

    1716

    4

    1444

    18

    8143

    15

    4620

    8345

    3062

    1131

    929

    210

    10

    36

    1

    195

    1

    5

    2627

    78

    223

    24

    2122

    7

    6

    5051

    4849

    1889

    90

    8788

    3457

    56

    16

    6968

    46

    3264

    2860

    5425

    852

    53

    1991

    92

    35

    67

    65

    63

    61

    575595

    47

    84

    82

    80

    43

    42

    4120 213736

    32

    24

    45

    4411

    23

    22958

    59

    33 17

    55

    54

    53

    52

    30

    31 26

    25

    393861

    85 112136

    1045993144

    102148146

    122

    114

    10394

    101147

    145

    1116686137

    123 121

    113

    168 167

    153185

    1 5 5

    1 5 6

    1 7 3

    1 7 7 1 6 1

    1 6 2

    1 8 3

    1 8 260 65

    70

    88

    89

    106105 1 5 7

    66

    108107 1 5 8

    67

    110109 1 5 9

    68

    69

    116115

    1 6 3

    71

    118117

    1 6 4

    72

    120119

    1 6 5

    73

    7475124

    125

    16976

    126127

    17077

    128129

    1717879

    130131

    1 7 4

    80

    132133

    1 7 5

    81

    134135

    1 7 6

    82

    83

    1381391 7 9

    84

    1401411 8 0

    1421431 8 1

    87

    86

    85

    64

    150

    96

    149

    186

    98

    56

    97

    151

    100

    58

    99

    15263

    40

    629190

    7170

    7372

    47

    48

    3837

    7574

    27

    49

    4039

    7776

    28

    50

    4241

    7978

    29

    51

    3433

    3635

    1312

    1514

    12

    13

    43

    1716

    4

    1444

    18

    8143

    15

    4620

    8345

    3062

    1131

    929

    210

    10

    36

    1

    195

    1

    5

    2627

    78

    223

    24

    2122

    7

    6

    5051

    4849

    1889

    90

    8788

    3457

    56

    16

    6968

    46

    3264

    2860

    5425

    852

    53

    1991

    92

    35

    67

    65

    63

    61

    575595

    47

    84

    82

    80

    43

    42

    4120 213736

    32

    24

    45

    4411

    23

    22958

    59

    33 17

    55

    54

    53

    52

    30

    31 26

    25

    393861

    4 1319112621

    9723

    17 15

    101824

    22123520

    18 16 1434 33

    25422 7

    2 8

    3 63 7 30

    31

    4039

    1 345

    67 2 10

    1112

    13141516

    1718

    19 8 9

    Parameter PDS-XADS Experiment MYRRAHDesign of FA hexagonal hexagonal hexagonalTotal Power 0.775 MW 0.43 MW 1.466 MWNumber of fuel pins 90 19 91Pin diameter 8.5 mm 8.2 mm 6.55 mmPitch 13.41 mm 11.48 mm 8.55 mmP/D ratio 1.57 1.4 1.3Pin length 1272 mm 1272 mm 1200 mmActive height 870 mm 870 mm 600 mmNr. of grid spacers 3 3 3coolant mean velocity 0.42 m/s 2 m/s 2.5 m/smass flow ~ 40 kg/s ~ 26 kg/s ~ 71 kg/ssub channel area 9330 mm² 1260 mm² 2760 mm²mean heat flux 38 W/cm² 100 W/cm² 131 W/cm²Inlet temperature ~ 300 °C ~ 300 °C ~ 200 °Coutlet temperature ~ 400 °C ~ 415 °C ~ 337 °C

  • 5 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    LBE Single rod experimentExperiment carried out atLBE Loop Thesys 2

    Technology forHeavy Liquid MetalSystems 2nd Version

    • Medium: Pb45Bi55• Inventory: 222 l• Flow rate: 2 - 14 m³/h• Diameter: 60 mm • 4 different flowmeterAccuracy + 0,5%

    • Oxygen control

  • 6 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    • Single rod layout:• Total power 22,4 kW• heated length 870 mm• Power density 100 W/cm²• Rod diameter dr 8,2 mm• Tube diameter D 60 mm

    • Measurement Range:• Temperature 200°C - 400°C• Velocity 0 -1.6 m/s• Prantl 0,016 - 0,03• Reynolds 5·104 - 5,6·105

    Results will be presented in Talk 6-16 "Turbulent liquid metal heat transfer along a heated rod within an annular cavity"

    Thermocouplespacer

    LBE Single rod experiment

  • 7 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experiment

    Technical details:• Temperature 20°C - 100°C • Flow rate 130 m³/h• Pressure 14,7 bar• H2O inventory 8 m³

    • Water rod bundle design identical with LBE rod bundle except for PMMA in active Zone needed for LDA measurements

    • Isothermal experiment• Measurement Range:

    Velocity: 0.1 - 10 m/s Reynolds: 103 - 9·104

    Experiment carried out atKALLA water loop

  • 8 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Pressure measurements• Fast pressure sensors Pa to Pg for component specific pressure loss, flow metering and vibration measurements

    Temperature measurements• Static temperature sensors T1 and T2 for overall temperature change

    LDA velocity measurements• LDA1 downstream venturi nozzle for inlet conditions• LDA2 upstream fist spacer for lateral flow distribution

    due to the bundle• LDA3 downstream 2nd spacer for lateral redistribution

    UDV velocity measurements• Measurement in each sub Channel type

    Water rod bundle experiment

    InletOutlet

    FootHead Flow equilizer & straightenerTest sectionPg

    Pa

    Pd,c,b

    Pf,e

    spacer positionLDA3 LDA1LDA2

    UDV

    T1T2u0

    u0

    u0

    g

    Sensor instrumentation:

  • 9 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    0,0

    0,5

    1,0

    1,5

    2,0

    2,5

    0 20.000 40.000 60.000 80.000 100.000Re

    Loss

    coe

    fficie

    nt CD

    Measured Spacer Loss CoefficientCalculated Spacer loss coefficient

    Water rod bundle experimentMeasurements of pressure loss Pa to Pg in different configurations to characterize loss coefficient of • Inlet section with foot and riser• Flow straightener• Test section• Spacer

    2.58 bar0.38 bar0.66 bar0.60 barExp Pressure loss

    5.70.78----Loss coefficient

    SpacerFlow straightner

    Test section

    Inlet section

    Experimental results of pressure loss measurementsat max velocity of 10m/s (Re 88.000)

    InletOutlet

    FootHead

    Flow equilizer Test section

    Pg

    Pa

    Pd,c,b

    Pf,e

    spacer positionLDA

    3LDA

    1LDA

    2

    UDVT1

    T2u0

    u0u0

    g

    Loss coefficient of the test section

    Loss coefficient of the spacer

    3

    4

    5

    6

    7

    8

    9

    10

    11

    0 20.000 40.000 60.000 80.000 100.000Re

    Loss

    coe

    fficie

    nt CD

    Measured Test Section Loss CoefficientCalculated Test section loss coefficient

  • 10 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experimentComparing experimental results: • Simple calculation of loss coefficient for used spacer given by average blockage ratio calculates a loss coefficient of 0.65

    a

    b

    fe

    d

    g

    25.0 upCD ⋅⋅

    ∆=ρ

    2

    7

    ⋅=AAC SD

    2.21 bar2.26 bar2.58 barTest section pressure loss 0.20 bar0.20 bar0.38 barSpacer pressure loss LBE Exp 300°CLBE Exp 200°CH2O Exp.

    • Calculated pressure losses for water and lbe experiment:

  • 11 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experimentCFD of the test section area

    Calculated pressure loss of the spacer geometry agrees very well with measured pressure loss.

    CFD 1/6 of the test section with modelled spacers(1.2M cells, kε model)

    InletOutlet

    FootHead

    Flow equilizerTest section

    Pg

    Pa

    Pd,c,b

    Pf,e

    spacer positionLDA

    3LDA

    1LDA

    2

    UDVT1

    T2u0

    u0u0

    g

    calculated pressure loss of the test section near a spacer

    0.40 Bar

  • 12 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experiment

    1,0E-10

    1,0E-09

    1,0E-08

    1,0E-07

    1,0E-06

    1,0E-05

    1,0E-04

    0,1 1,0 10,0 100,0Frequency [Hz]

    Amplitud

    e

    dp103

    dg

    Measurements of pressure loss on inlet and test section area with high time resolution:

    • Negligible influence of flow induced vibrations onto the experimental setup.

    FFT of the time resolved pressure of the test section

    -0,1

    0,0

    0,1

    0,2

    0,3

    -2,0 -1,5 -1,0 -0,5 0,0 0,5 1,0 1,5 2,0Time [s]

    Amplitud

    e

    dp101 103

    Cross correlation calculation of the time resolved pressure of the inlet and test section

    ab dg

    InletOutlet

    FootHead

    Flow equilizerTest section

    Pg

    Pa

    Pd,c,b

    Pf,e

    spacer positionLDA

    3LDA

    1LDA

    2

    UDVT1

    T2u0

    u0u0

    g

  • 13 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experiment

    0,00

    0,20

    0,40

    0,60

    0,80

    1,00

    1,20

    1,40

    1,60

    -1 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1rel. distance

    u/u m

    ean

    Re = 5.000Re = 8.000Re = 10.000Re =26.000

    LDA

    LDA Measurements of 1d velocity downstream the venturi nozzle at the end of the flow straightening section :

    • Symmetric flow distribution, flow conditionning works more reliable compared to the single rod experiment.

    Normalized velocity profile downstream the venturi nozzle at the end of the flow straightening section

  • 14 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experiment

    LDA

    CFD of the velocity profile at the end of the flow straightening section:

    Velocity profile downstream the venturi nozzle at the end of the flow straightening section with Re 8000. (cfd with 960.000 cells , kεmodel)

  • 15 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Water rod bundle experiment

    LDA

    • 1d Measurements of the velocity profile in the testsection area:

    1d velocity profile at the beginning of the testsection (5m/s Re 38000)

    • 2d Measurements of the velocity profile in the testsection area are planned.• Additional cfd planned.

  • 16 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    16 Thomas Wetzel, Forschungszentrum Karlsruhe, 15.09.2009

    LBE rod bundle experiment

    LBE rod bundle experiment

    Technical details:• Temperature 190°C - 450°C • Flow rate 47 m³/h• Pressure 5,9 bar• Test ports 3• Usable height 3405 mm• O2 Control �• LBE-Inventory 4 m³ (42 to)• Tube diameter 107mm

    Experiment to be carried out atLBE Loop THEADES(THErmalhydraulics and Ads DESign)

  • 17 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    17 Thomas Wetzel, Forschungszentrum Karlsruhe, 15.09.2009

    Pressure measurements• Fast pressure sensors for component specific pressure loss, flow metering and vibration measurements.

    • Pitot tube for pressure distribution in sub channels

    LBE rod bundle experiment

    InletOutlet

    FootHead Flow equilizer & straightenerP P

    Pd,c,b

    P T

    Tu0

    u0

    g

    u0

    Test section

    moveable TC-SpacerTC-Spacer

    spacer position

    TC-Pinfixer

    P P P

    Sensor instrumentation:

    Temperature measurements• Static temperature sensors T for overall temperature change

    • Fast TC equipped spacer and Pinfixer for subchannel and rod surface temperature distribution

  • 18 Karsten Litfin, FR09, 08.12.2009KIT – die Kooperation vonForschungszentrum Karlsruhe GmbHund Universität Karlsruhe (TH)

    KArlsruhe Liquid metal LAboratoryKALLA

    Conclusions• Single rod experiments show a large influence of buoyancy on the velocity profile even at relatively high Reynolds Numbers while the temperature field is less influenced. This yields to an enhanced heat removal.

    • Currently used Nusselt correlations are rather conservative.

    • Water rod bundle experiments show very good agreement of measured pres-sure loss with numerical predictions in the fully turbulent flow regime whereas in the transitional regime secondary flow leads to a rising loss coefficient

    • Measurements show negligible flow induced vibrations onto the setup

    • LBE rod bundle experiments will be conducted soon and hopefully give new insights onto the heat transfer.

    Acknowlegement• The work is supported in the framework of the IP-EUROTRANS project; contract number FI6W-CT-2004-516520