+ All Categories
Home > Documents > FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web...

FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web...

Date post: 30-Jan-2018
Category:
Upload: vokien
View: 214 times
Download: 0 times
Share this document with a friend
38
Important Term & Condition : The firm submitting downloaded tender documents from the College website shall attach bank draft/postal order as the cost of the tender i.e. Rs. 500/- separately in addition to the earnest money deposit in the shape of FDR/CDR otherwise the tender will be rejected. 1.
Transcript
Page 1: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

Important Term & Condition :

The firm submitting downloaded tender documents from the College website shall attach bank draft/postal order as the cost of the tender i.e. Rs. 500/- separately in addition to the earnest money deposit in the shape of FDR/CDR otherwise the tender will be rejected.

1.

Page 2: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

CIVIL ENGINEERING DEPARTMENT

MATERIAL TESTING Laboratory

S.No. Proposed Equipments Specifications Quantity1 Computerized Compression

testing Machine 2000 kN capacity.Conforms to IS:14858 (2000) Fully computer controlled-Desktop, Capacity 2000KN, Resolution 0.01, Max clearance between platens 370mm, Max distance between side plates 340mm, Platen size = 222mm dia. suitable for testing Specimens of size: 100 mm & 150 mm cube & 100 mm & 150 mm dia Cylinder and Brick testing platens.Complete with requisite Computer Hardware and Software.

01

2. Computerized Compression testing Machine 500 kN capacity.

Conforms to IS:14858 (2000) Fully computer controlled-Desktop, Capacity 500KN, Resolution – 0.01, Max clearance between platens 390mm, Max distance between side plates 260mm, Platen size = 140 mm square for testing Specimens of size: 50mm,70.6mm & 100 mm.Complete with requisite Computer Hardware and Software.

01

3. Curing Tank Having capacity to store 36/72 Moulds of 150mm/70.6mm size fully insulated double valve and having lid. Temperature Range: Ambient + 5º C to 95~ 100º C, provided with a heater, thermostat and re-circulated pump to maintain constant temperature and having a drain valve.

01

4. Electronic weighing balance (LCD display)

Capacity 60 kg and least count 5 gm Capacity 10 kg and least count 0.5 gm

01 each

5. Concrete Test Hammer Testing surface normal concrete in buildings/bridges and other concrete structures.Measuring Range : 10 - 70 N/mm2Impact Energy: 2.207 NmRebound Number to be read from dial.Complete with Testing Anvil Grinding Stone, Operating Instructions and Calibration certificate.

01

SOIL MECHANICS Laboratory

S.No. Name of the Equipment Specification Quantity

1 Electronic Weighing balance (LCD display)

Capacity 30 kg and least count 2 gm Capacity 600 gm and least count 0.01 gm

01 each

Page 3: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

Surveying- Laboratory

S.No.

Name of the Equipment Specification Quantity

1 Chain 30m long Metric Chain of superior quality, 150 links,

with Brass Handles. To be supplied with 10 arrows.

10 No.

2. Prismatic Compass Prismatic Compass with stand with least count of 10

minutes.

10 no.

3. Ranging Rod Ranging rod made of steel conduit pipe, alternative

painted in two colours ,size 3m

60 no.

4. Levelling staff Levelling staff 4m high made of aluminum,

telescopic type, accurately printed in graduations

having 5mm in front and 1mm backside, packed in

waterproof canvas cover

10 no.

S.No.

Name of the Equipment Specification Quantity

1 Chain 30m long Metric Chain of superior quality, 150 links,

with Brass Handles. To be supplied with 10 arrows.

10 No.

2. Prismatic Compass Prismatic Compass with stand with least count of 10

minutes.

10 no.

3. Ranging Rod Ranging rod made of steel conduit pipe, alternative

painted in two colours ,size 3m

60 no.

4. Levelling staff Levelling staff 4m high made of aluminum,

telescopic type, accurately printed in graduations

having 5mm in front and 1mm backside, packed in

waterproof canvas cover

10 no.

FLUID MECHANICS Laboratory

S.No. Name of the Equipment Specification Quantity

1 Hydraulic Bench Unit consists of self contained water recirculating unit provided with a sump tank, centrifugal pump and top tray to contain water drained from experiment.Set ups on to it and outlet to return it to the sump.Size of table 1500* 1200* 800 mmMeasuring tank of 80 litres capacitySump tank 150 litres capacityCentrifugal pump of 0.5 H.PNecessary piping, valves, fitting and stop watchRigid fabricated MS frame structure for supportTop tray , measuring tank and sump tank will be lined with fibre glass lining for corrosion prevention.The unit must have the provision to carry out following

01 no.

Page 4: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

experiments:a) Impact of jetb) Flow measurement by Orificemeter and

Venturimeterc) Orifice, mouthpiece apparatusd) Bernoulli’s Theorem apparatuse) Flow over Notches ( Rectangular, Triangular and

trapezoidal) apparatus f) Losses in pipes & fittings. g) Reynold’s Appartus h) Pitot’s static tube Appartus.

Deptt. of Electronics & Communication Engg

01. Basic Electronics Lab. S.No. Name of the Equipment Qnt’y Sepecification

1 CRO 100MHz (Electronic CRO)

02 100 M Hz Multi function oscilloscope with Auto set save & Recall readout & curser 2 chanel 1mv/div-20v/div.Delay line 14KV CRT time base / F: 0.55 sns/div, B:20ms-Sns/div with 2 Trigger Triggering DC-250 MHz, Automatic peak to peak alternate Trigger.

2 Study of Oscillator Trainer Kit

04 Modular type ckt. On Glass epoxy PCB providing experimental study of colpitts Hartly, RC phase shifting and wien Bridge Oscillators with connecting leads and modules with manual & patch cards.

3 Sweep Function Generator 02 Wide range of frequencies from 0.0002HZ-20MHZ choice of six selestable waveforms. Digital read out for the O/P frequency, tigger and gate modes with adjusttable start/stop control, wide sweep the time vage from 25HZ to 0.02HZ with manual & patch cords.

4 Study of FET 04 Kit circuit should consists of separate circuit for characteristics, FET as a switch, FET amplifier, FET as voltage follower amplifier with manual & patch cords.

5 Study of Voltage Regulators. 02 Demonstrate the Principle of all detail study of Transistor series voltage Regulator shunt Ragulator three terminals fixed voltage Regulator (Positive-78xx & Nagative-79xx) and verable voltage Rgulator.-LM 317 & LM337 the kit should be provided with all necessary instrumentation for above voltage Regulators raw rectified filter AC supply Three terminals voltage Regulators fix and variable Two 3

Page 5: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

½ Digit LED voltage 200mv, 2v,20v selection switch & current meter (2mA, 20mA & 200mA) with selector switch, with manual patch cords.

6 Transistor Feed Back Amplifier Kit

02 Circuit should be on glass epoxy PCB with high quality printing & green marking on trace side 9v in power supply, 1KHZ built in sine wave with o-1v o/p two stage transistor amplifiers, with manual patch cords.

7 Study of Transistors All Types

02 Trainner kit should be on single glass epoxy PCB with screen-printed complete circuit layout for detail study of Transistor H-Parameters, CB/CC.CE & thermal stabilety with Manual & patch cords.

8 Hand Held Digital Multimeter

03 DC/Dc volt measurement, Current measurement, Resistance measurement, Diode test, Transistor Test-PNP/NPN, & E,B,C, Disply-LCD, 3999 coints mass Test leads Electric voltage 1500v, 10A Battery 9v +-5v, 3 terminals strip, tiepoint 920 and 5 distribution strip tie points 500 & 4 binding ports.

9 Study of Complementary Symmetry power Amplifier

04 The board consists of (power transistor BD 139), VCE 55 to 60V VBE=100v, Iv=100mA, hfe=4—160, resistor power rating 0.5w Electrolytic capacitors rating 1.5v, inductors opereting temp. ambient with manual & patch cords.

10 Push-pull Amplifier Trainer kit

04 Pvovision to study differentail &Class B Push pull amplifier on Board sine wave generator with variable frenquency and amplitude & DC power supply +12v, -12v, +5v, -5v, variable DC power supply 0 to 1v, sine wave generator frequency 800HZ to 10KHZ amplitude 0 to 5VPP, Main supply 230v, +- 10% 50HZ fuse :350 mA trainer should be on legend PCB with screen printed complete circuit layout for detail study, Housed in a Modeled case with patch cords & manuals.

02. Digital Electronics Lab

S. No Name of the Item Qty.01 Computer with 600VA UPS 01

02 Stools 10

03. LIC / PULSE Circuit Lab S.No. Name of the Equipment Qnt’y Sepecification

1 CRO 100MHz (Electronic CRO)

03 100 M Hz Multi function oscilloscope with Auto set save & Recall readout & curser 2 chanel 1m v/div-20v/div.Deley live 14KV CRT time base / F: 0.55 sns/div, B:20ms-Sns/div with 2 Trigger Triggering DC-250

Page 6: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

MHz, Automatic peak to peak atternate Trigger.

2 Function Generator/ Counter (1MHz)

03 Output waveforms-Sine, squre, tringular, Ramp, Pulse and externally sweepable and modulated AM & FM.Freq. Range-0.01Hz to 1MHz in 8 decade ranges.

3 Hand Held Digital Multimeter

01 DC/AC Volt measurement, current Measured, Resistance measurement, Diode Test, Transistor Test-PNP/NPN & E, B,C, Display-LCD, 3999 counts max, Test leads Electric vaturgo 1500V, 10A, Battry 9V.

4 Bread Board with power Supply

03 +-5v, +-15v 3 terminal strip, tiepoints, 92D & 5 distribution strip tiepoints 500 & 4 binding parts.

5 OP-Amp. Trainer Kit 02 Op Amp as Adder, Subtractor, Differentiator, Intergrator, Differenttial Amp, Comparator, Inverter, Inverting, Non-Inverting Amp, Peak detector, Sq wave generator with Training Manual and connecting patch cords.

6 OP-Amp as Filter 02 High pass and low pass fitter, Band pass, Band Rejection, Notch fitter supply I/15v with Training Manual & connecting patch cords.

7 Astable & Monostable Multivibrater Trainer Kit

02 Astable, Monostable, Bistable multi vibrater, with Training Manual and connecting patch cords.

8 OP-Amp as Cllipper & Clamper Circuits

02 Using diodes with positive clipping ckts, negative clipping, Combination clipping with Training Manual and connecting patch cords.

9 Analog IC Tester 01 IC pack to test 6,8,10,14,18,20,24,28,& 40 pin Ics in DIPpackage potential free 20 pin ZIF socket for testing analog Ics 16 character x2 line LCD dot matrix supply voltage 230v AC.

04. VLSI Lab

S.No Name of the Item Qty.01 Computer with 600VA UPS 01

02 Stool 15

05. Communication Lab.

S. No. Name of the equipment Qnt’y specification1 C R O 200 MHz 3 Digital Storage Oscilloscope

(Specification): (200MHz=01, 100MHz=02)Bandwidth: 200 MHz,No. of Channels: Two, Display: ColourSample Rate on Each Channel: 2.0 GS/s

2 Function Generator 4 Range : 1 Hz to 100 MHzSine ,square, triangle, ramp, pulse and TTL output4 digit 7 segment display. O/P Power:+13-127dBm Level Accuracy : ±1dB

3 AM Signal Generator 2 72 MHz400Hz and 1KHz in built AM signal

Page 7: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

4 ASK Modulation / demodulation kit 2 Bit clock Generator 152 Hz to 13KHz8 bit word GeneratorSPDT switches to select 0’s & 1’sDivided by 16 counterFault creation facility with jumpers

5 TDM/PAM & PPM, PWM Experiment Panel.

02 (Provided with 20 banana + 10 TPs + 10 LEDs) Crystal Freq.-10 MHz, should Share common resources like 2 FGs – Carrier & Audio , sync sine wave microphone / loudspeaker Amplifier, Low Pass Filter etc from Master unit (MU)Switched faults •1 channel Sampling / Reconstruction & 4 Channel TDM / PAM & Demodulation Modulator: Analog i/p channel: - 4 Nos, 10 Vpp, Bipolar. Settable Sampling Freq. (1of 7): 64 / 32 / 16 / 8 / 4 / 2 / 1 KHz With Settable Duty Cycle 10-90 % in decade steps.b) De-Modulator : Clock Regeneration using PLL, LPF, 1/2/3 Wire Communications. PWM / PPM Mod – Demod. Modulator: I/P freq–Audio range (Sine) @ 0-8 Vpp, Carrier Freq - 64KHz(TRG)@ 8 Vpp O/P – TTL.b) De-Modulator: LPF (MU), PPM is converter into PWM then Demodulated.

6 Pulse Code Modulation(Transmitter) & Receiver( Demodulation) Kit

02 For Transmitter I/P Channel :02No TDM Pulse Code Modulated. On Board Signal :1 Khz, 500Hz Variable Amplitude, Synchronized Sine waves. Parity Code facility. Even –Odd, Hamming, No parity. Mode of Op: Fast/slow.For Receiver I/P Channel : 02No TDM Pulse Code Modulated data. Receiver Clock : Generated by PLL(fast Mode).

7 Delta, ADM, Modulation Demodulation Expt. Panel

02 Should Consist of Voltage comparator, differential amplifier, TTL TO Bipolar, Bipolar to TTL, Bistable.- Switched faults -Delta, CVSD (adaptive delta), Adaptive control circuits 2nos. each providing 2 bit binary code, to control gain of an integrator for adaptive delta modulation.

8 Data Conditioning( Transmitter) / Data Reconditioning ( Receiver) Kit

02 For Transmitter : On Board data Simulator: NRZ-L PatternData Format Coding : NRZ(L), NRZ (M), NRZ (S) Bi phase (Manchester) ,Bi phase(Mark), Bi phase(Space), RZ,AMIOnBoard Carrier : 2MHz (0 Deg), 1MHz (0 Deg)SineWaves: 1MHz (180 Deg)For Receiver : Data Format (DeCoding) NRZ(L), NRZ (M), NRZ (S) Bi phase (Manchester) ,Bi phase(Mark), Bi phase(Space), RZ,AMICarrier demodulation :ASKTechniques :FSK, PSK

Page 8: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

9 RF Tuned Amplifier 03 100KH-200KHz Single Tuned Amplifier using Bi-Polar JN TransistorIn-built -12V DC Regulated Power Supply.

06. Embedded System Lab

Philips 89v 51 RD2BN with 4 ports with Vcc & GND on each connection. Power jack 5 Volt supply

and 11.0592 MHz crystal clock, So that it can used in standalone mode also. With USB interface

programming capable and software download facility.

CPU with 4Kx8 ROM, 2-16 bit counter/timer

Boolean processor, Full static operation,

Memory addressable capability, 64K ROM and 64 RAM,

CMOS and TTL comfortable speed ranges at Vcc = 5V

1) 0 – 16 MHz

2) 0 – 33 MHz

LCD Interfacing, Seven segment display

Buzzer, Key pad interfacing, EP ROM interfacing.

Note: Reprogrammable facility for the controller on board.

Page 9: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

ELECTRICAL ENGINEERING DEPAERTMENTPC/Computer Lab.

REQUIREMENT OF EQUIPMENTS - 2014-15

S.No.

Name of the kit Qnty Specifications

01. Photostat Machine. 01 Digital Photocopier, Size A-3, Category-Duplex, Printer connectivity, networking, Zoom (25 to 400%)

Make: Canon/Ricoh.02. Colour Printer 01 Colour printer with tanks, size A-4, wi-fy,

Make: Canon, Brother, HP03. Laser Printer 01 Laser Printer (Mono) Connectivity with Microsoft

Windows 7, Windows Vista, Windows XP, Windows Server 2003, Windows Server 2008.

Make: Canon, Brother, HP.04 Computer Systems 15 Desktop PC

i. CPU: Intel Core i7-2600 or Higher (3.4 GHz, 8 MB Cache or better or Higher, 4 cores).

ii. Chipset: Intel Q67 Express or higher.iii. Memory Slots: 4 DIMMiv. Memory: 8 GB 1333 MHz DDR3 SDRAM v. Hard Disk Drive: 1 TB.vi. Optical Drive-SATA Super Multi DVD writer.vii. Monitor: 47 cm (18.5 inch) larger LED Digital

Colour Monitor TCO- 05 certified.viii. Mouse: Optical with USB interface.ix. Ports: 6 USB Ports (with at least 2 in front),

audio ports for microphone and headphone in front.

x. Graphics: Integrated Intel HDxi. Network Interface: Integrated Intel 82579LM

Gigabit Ethernet, Intel Pro 1000CT Gigabit 802.11b/g/n wireless.

xii. Operating System: Windows 7 Professional Preloaded with Media and Documentation and Certificate of Authenticity.

xiii. OS Certifications: Windows 7 OS and Linux certification.

xiv. Audio: Realtek ALC261 high definition audio codec (all ports are stereo).

xv. Preloaded Software: Pre- installed Intel software Protect Tools security Suite, Software Management Agent, Comp trace for Desktops agent, Vision Diagnostics, PDF complete corporate Edition, Microsoft Office, Norton or McAfee or e-Scan or Trend Micro or Quick Heal Antivirus (Latest Version) with 1 Year License.

xvi. In built Wifi card xvii. In built Speakers

05. UPS 15 800VA Off Line with 60 Mins Backup

Page 10: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

REQUIREMENT OF EQUIPMENTS FOR ELECTRICAL MEASUREMENT LAB. AND CONTROL LAB

2014-15

S.No. ITEM QTY. SPECIFICATION01. Measurement & control of

temperature using RTD.(TRAINER KIT)

04 Object:To carry out. Measurement & control of temperature using RTD.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number patch cords/connecting leads..3)RTD probe immersion type, transducer range 0-200 deg. Centigrades, measurement range 0-70deg. Cent.4. On/off type temperature set by pot. Over full range 1000W heater, temp. set control, present temp. display control, 3 ½ digits digital meters.5) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure.

02. Measurement & control of temperature using Thermistor.

(TRAINER KIT)

04 Object:To carry out. Measurement & control of temperature using Thermistor.Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number patch cords/connecting leads..3) Thermistor sensor, transducer range 0-100 deg. Centigrades, measurement range 0-70deg. Cent.4. On/off type temperature set by pot. Over full range 1000W heater, temp. set control, present temp. display control, 3 ½ digits digital meters.5) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure.

03. Measurement & control of temperature using Thermocouple.

(TRAINER KIT)

04 Object:To carry out. Measurement & control of temperature using Thermocouple.Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number patch cords/connecting leads..3),Transducer- Thermocouple sensor probe, immersion type, iron constantan probe range 0-400 deg. Centigrade, measurement range 0-70deg. Cent.4. On/off type temperature set by pot. Over full range 1000W heater, temp. set control, present temp. display control, 3 ½ digits digital meters.5) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure.

04. Angular measurement using potentiometer transducer.

(TRAINER KIT)

04 Object: To measure Angular measurement using potentiometer transducer.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number patch cords/connecting leads..3) Excitation 5V DC , 110% of rated capacity, 0-345 deg. Rotary movement, 3 ½ digit digital meters.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure.

05 Measurement of intensity of light using LDR & Photocell,

(TRAINER KIT)

02 Object: To carry out measurement of intensity of light using LDR & Photocell.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.

Page 11: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

2) Adequate number patch cords/connecting leads..3) Transducer type-LDR & photocell, 1megaohm, 10mV, LDR & Photocells conncected through EP socket, 200lux(Relative measurement), 3 ½ digit digital meters calibrated in lux..4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure

06 Compensation Design

(TRAINER KIT)

02 Built in square & sine wave generators for transient & frequency response studies. Frequency adjustable from 25 Hz to 800 Hz app. Complete in all the respects except a measuring CRO to perform the following experiments:1) Transient and frequency response measurement of uncompensated system.2) Design & implementation of compensator.

3) Verification of the performance of the compensated system in the time and/or frequency domain.

07 LVDT Trainer Kit

,

02 With inbuilt 2KHz excitation frequency, displacement up to 20mm, micrometer, center zero digital meter and other required meters, displacement signal for recording.

08 Maxwell’s L/C Bridge 04 ± 12 VDC AT 100 mA, I.C. Regulated Power supply, 1 KHz Sine wave Oscillator, Audio Amplifier and speakers for null detection, Five unknown values of capacitors and three unknown values of inductors selected by band switches, Two decade resistance in 100 ohm steps. Potentiometer and adequate no. of other electronic components.

09 Wein’s Bridge 04 P= Three decade resistance dials having the range × 100 Ω × 10 Ω & 1Ω.Q= Three more decades of same value as in P.R= Two decade resistance dials having range × 10 Kilo Ohm & 1 Kilo Ohm.C1= Two fixed standard capacitor having values 0.01 mfd & 0.2 mfd.C2= Four unknown capacitors.R2 = Two unknown resistances, n build AC supply frequency 1 KHz with head phone and 31/2 Digit digital null detector.

10 Conversion of Galvanometer into Ammeter

02 + 5 DC at 50 m A, I.C. regulated power supply.Galvanometer 30-0-30, DC milli ammeter 0-50 mA. Potentiometer and other electronic components.

11 Wheatstone Bridge(Complete with all accessories)

04 1 milliohm to 1.1 Mega ohm.Accuracy: 0.05%

12Three phase energy meter (Analog)

02 Three phase four wire , capable of functioning on 440 V, 50 Hz, 16 or 20 amp,

13 Stepper Motor (with µP interface)(Complete with stepper motor, power supply position indicator, µP interface user software.)

01 High performance 8085 A CPU operating at 3 MHZ4 K user RAM 6116 . Built in stepper motor. And other necessary electronic accessories required to perform the following experiments:

1) Study of operation & characteristics of a stepper Motor & its control through microprocessor.2) Measurement of angular resolution.3) Direction & speed control of the motor.4) Study of the effect of the mechanical resonance.

14 Digital storage oscilloscope

Band width: 100Mhz, 4channel, Display: colour

02Accessories:

1. Current probe 100A AC/DC 100KHZ.2. High voltage probe 100x1KV, 250Mhz.

Page 12: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

3. Advanced waveform processing software.4. USB Port5. Probe×2, power cord, user’s manual

Features:Digital real time sampling- Accurately capture signals, FFT Analysis, wave form & data logging, should make accurate measurement, even on low level signals, easy to use front panel controls, quickly store & transfer your wave form & settings.

15Microprocessor Based Programmable Cable Fault Localizer(capable of localizing complex nature of fault where all cores are shorted & also multiple faults)

01 Power source 12v DC Battery of 230 v AC mains, cable length 5 Km (Max.), fault resistance up to 1 Mega ohm, measured by 1 Kv meggar, accuracy +/-5% or better.Suitable for all types of LT & HT, armoured & un-armoured cables up to 33 Kv of all classes like PV C, PLCC, PILC & XLPE cables.With all necessary accessories to carry out the test.

16 Wattmeter ( Analog) 04 300/600V, 5A/10A, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet.

17 Voltmeter (AC) 0-10V

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

18 Voltmeter (AC) 0-500V

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

19 AC Ammeter ( 0-1 Amp)

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

20DC Volt Meter (0-1 Volts.)

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

21 DC Milli Volt Meter (0-500 mV.)

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

22DC Milliamper Meter (0-500 micro amp.)

05 4-1/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

Page 13: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

POWER ELECTRONICS LAB.

REQUIREMENT OF EQUIPMENTS - 2014-15

S.No. ITEM QTY. SPECIFICATION01. Voltage Commuted

Thyristorised Chopper

(TRAINER KIT).

03 Object: To study the step down voltage commuted thyristorised chopper.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number patch cords/connecting leads..3)Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

02. Current Commuted Thyristorised Chopper

. (TRAINER KIT)

03 Object: To study the step down Current commuted thyristorised chopper.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords./ connecting leads.. 3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

03. Study of SCR & AC Phase Control

(TRAINER KIT)

05 Object: To perform the following experiments:

1) Resistance trigger ckt. For SCR to be operated as half -wave static switch and limited range half- wave phase control.2) R.C. trigger ckt. For SCR operated as full range half wave phase control.3) R.C. trigger ckt. For SCR connected in bridge full range full wave phase control.4) Half-wave phase control SCR using UJT trigger ckt. Resistance controlled ramp.5) Full- wave phase control with inverse parallel SCRs using UJT trigger ckt. Resistance controlled ramp.6) Full-wave phase control with half controlled bridge conventor using UJT trigger ckt. Resistance controlled ramp.7) UJT trigger ckt. With series transistor controlled ramp.8) UJT trigger ckt. Using shunt transistor controlled pedestal.9) UJT trigger ckt. Controlled pedestal with improved ramp.10) UJT trigger ckt. Resistance controlled pedestal with cosine- modified ramp.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords./ connecting leads..3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure .

04. Triac & AC Phase Control

(TRAINER KIT)

05 Object: To perform the following experiments:1) Study of Triac characteristics & its operation in all the four modes i.e. 1+, 1-, 111+ & 111-.2) Gate control triac with NPN transistor.

Page 14: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

3) Gate control of triac with PNP transistor.4) Phase control with triac and diac as pulse generator for gate trigger.5) Light dimmer with triac- hysteresis effect and its minimization by gate slaving technique.6) Study the radio frequency interference (RFI) in phase control and its suppression by RFI filter.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords./ connecting leads..3) Good quality, reliable terminal/sockets required at appropriate places on panel connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

05. Triggering Ckts. For SCR

(TRAINER KIT)

03 Object: To study the SCR triggering ckts. Using 1) Resistor (R) triggering ckt.2) Resistor- Capacitor (R-C) triggering ckt.3) Uni-junction transistor (UJT) triggering ckt. (UJT Relaxation Oscillator).4) Half -wave control rectifier.5) Full -wave control rectifier.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure .

06. IGBT, MOSFET, SCR, Triac, Diac characteristics study Trainer

(TRAINER KIT)

03 Object:

1) Study of VI characteristics of SCR.2) Study of VI characteristics of Triac.3) Study of Transfer characteristics of MOSFET4) Study of Transfer characteristics of IGBT.5) Study of Dynamic characteristics of MOSFET6) Study of Dynamic characteristics of IGBT.

Other Requirements are:1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains2) Required no. of inbuilt regulated voltage power supplies to perform the experiments.3) Voltmeter & Ammeter of required rating for the measurement proposes..4) Adequate number of patch cords. ./ connecting leads..

5) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.6) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

07. Single Phase AC Voltage Controller

(TRAINER KIT)

03 Object: Single phase AC regulator with R & R-L load.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.

2) Adequate number of patch cords. ./ connecting leads..

Page 15: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

08. Single Phase SCR Half Controlled Converter

(TRAINER KIT)

03 Object: Single phase Half controlled conventer with R & R-L load.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

09. Single Phase SCR Bridge Converter

(TRAINER KIT)

03 Object: Single phase fully controlled converter with R & R-L load.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

10. Single Phase Cyclo Converter

(TRAINER KIT)

05 Object: Single phase cyclo converter with different output frequency with the different voltage.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

11. UJT Firing Ckt. For SCR Converter

(TRAINER KIT)

05 Object : 1) Study of UJT firing Ckt.2) Testing of Single phase fully controlled converter using UJT firing.3) Testing of single phase half-wave controlled converter.4) Testing of single phase AC regulator UJT firing.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords./ connecting leads...3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

12. UJT Characteristics & Oscillator study Module

03 Object: 1) Study of UJT Relaxation Oscillator.2) Study of ON delay timer.

Page 16: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

(TRAINER KIT) 3) AC regulator using SCR.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords./ connecting leads...3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure

13. BJT, IGBT, MOSFET –Characteristics Trainer

(TRAINER KIT)

03 Object: 1) Measurement of ON delay period (TD –ON).2) Measurement of Rising period (TR).3) Measurement of Turn-ON period (T –ON).4) Measurement of Conduction period(T)5) Measurement of Storage period (Ts).6) Measurement of Falling period (Tf).7) Measurement of Turn-OFF period (T–OFF).8) Measurement of OFF period.

Other Requirements are:1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains2) Required no. of inbuilt regulated voltage power supplies to perform the experiments.3) Voltmeter & Ammeter of required rating for the measurement proposes..4) Adequate number of patch cords. ./ connecting leads..5) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.6) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure.

14.. Forced Commutated Circuits

(TRAINER KIT)

05 Object: To study the forced commutated Circuits.

1) Class-A or self commutation by resonating the load.2) Class-B or self commutation by an LC Circuit.3) Class-C or commutation through charged capacitor switched by another load carrying SCR.4) Class-D or commutation through charged capacitor switched by an axulliary SCR.5) Class-E or an external pulse source commutation.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure

15 Single Phase Fully –controlled Bridge Converter

(TRAINER KIT)

03 Object: To study and obtain the single phase fully controlled bridge converter.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains. ./ connecting leads..

2) Adequate number of patch cords.3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave

Page 17: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure

16 Single Phase Half- Wave controlled Converter

(TRAINER KIT)

03 Object: To study and obtain the wave forms for single phase half-wave controlled converter.

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..

3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure

17 UJT Relaxation Oscillator

(TRAINER KIT)

03 Object: 1) Study of effect of V on peak point & Valley point voltage.2) Operation of UJT relaxation oscillator & its use as SCR tigger ckt.3) Control of UJT trigger pulses with shunt transistor.4) Study of variation in gate resistance & capacitance, resistance of source & drain and their effect on trigger pulse characteristics of UJT relaxation oscillator.5) Various configurations of UJT relaxation oscillator type 1 (low output impedance), type 2 (moderate output impedance) & type 3 (high output impedance).

Other Requirements are: 1) The unit must be operative on 230V+/- 10% at 50 Hz AC mains.2) Adequate number of patch cords. ./ connecting leads..3) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & procedure

18 Digital storage oscilloscope

Band width: 100Mhz, 4channel, Display: colour.

05 Accessories:1. Current probe 100A AC/DC 100KHZ.2. High voltage probe 100x1KV, 250Mhz.3. Advanced waveform processing software.4. USB Port5. Probe×2, power cord, user’s manual

Features:Digital real time sampling- Accurately capture signals, FFT Analysis, wave form & data logging, should make accurate measurement, even on low level signals, easy to use front panel controls, quickly store & transfer your wave form & settings.

19 Digital storage oscilloscope

Band width: 200Mhz, 4channel, Display: colour

03 Accessories:1. Current probe 200A AC/DC 100KHZ.2. High voltage probe 100x1KV, 250Mhz.3. USB Port4. Probe×2, power cord, user’s manual5. Advanced waveform processing software

Features:Digital real time sampling- Accurately capture signals, FFT Analysis, wave form & data logging, should make accurate measurement, even on low level signals, easy to use front panel controls, quickly store & transfer your wave form & settings.

Page 18: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

20 DC Milliamper Meter (0-100 m amp.)

10 41/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

21 DC Voltmeter (0-50V) 10 41/2 Digit LED display digital.,Mains operated 230v, single phase, power coated cabinet, accuracy 0.5%.

22 DC Milliamper Meter (0-20 m amp.)

05 Analog, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet for carrying out practical works

23 DC Milliamper Meter (0-50 m amp.)

05 Analog, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet for carrying out practical works

24 DC Milliamper Meter (0-100 m amp.)

05 Analog, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet for carrying out practical works

25 DC Voltmeter (0-50V) 05 Analog, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet for carrying out practical works

Page 19: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

BASIC ELECTRICAL ENGG. LAB.REQUIREMENT OF EQUIPMENT - 2014-15

01. Kit for verification of laws & network theorems in DC Ckts.

05 Kit must be capable of verifying following laws:

Ohms law/KCL/KVL Series & Parallel Laws for resistances/super position theorems/max. Power transfer theorems/Thevenin’s theorem/Norton’s theorem.Other requirements:1) Kit must have inbuilt required no. of regulated voltage power supplies to perform the experiments.2) Voltmeters & Ammeters of required rating for the measurement purposes.3) Adequate number of patch cords. ./ connecting leads..4) Good quality, reliable terminal/sockets required at appropriate places on panel for connection/observations of wave forms.5) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure

02. Digital Wattmeter 06 230/440V AC +/- 10%, 50Hz, 4 ½ digits, current 5A/10A, single phase, power coated cabinet, accuracy 0.5%.

03. Analog Wattmeter 06 300/600V, 5A/10A, 50Hz, Accuracy 0.5% at 27 deg centigrades, fitted in wooden cabinet.

04 Transformer

(Fitted in wooden/metallic insulated box .)

Rating:12-0-12Volts

05 Kit for performing experiment “To determine the turns ratio of a Transformer”

Other requirements:1) Good quality, reliable terminal/sockets

required at appropriate places on panel for connections.

2) Voltmeters of required rating for the measurement purposes.

3) 3) Adequate number of patch cords. ./ connecting leads..

4) Strongly supported by detailed operating instructions, giving details of the object, theory connection details & design procedure

Page 20: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

REQUIREMENT POWER SYSTEM LAB.

S. No. Name of the Equipment Specification Qty.01. Experiment kit to A,B,C,D,

parameter, hybrid parameter & image parameter of given transmission model

Four action of transmission on line operatable at 220V with current rating at 2 Amp. Connected in π network, a continuous variable power supply with two digital voltmeter and two digital ammeters, mounted on front panel fitted in M.S. sheet box complete with patch cords for inter connection & manual detailed calculation supplied along with the set up.

01

02. Experiment set up to study the performance of long transmission line under no-load and under light load condition

Four action of transmission on line operatable at 220V with current rating at 2 Amp. Connected in π network, a continuous variable power supply with two digital voltmeter and two digital ammeter, mounted on front panel ,with resistive inductive, capacitive load fitted in M.S. sheet box, complete with patch cords for inter connection and manual.

01

03. Experiment kit to study the performance characteristics of a typical DC, distribution system (Radial Configuration)

DC distribution network at 100V, with current rating at 2 Amp. And is consisting of ‘5’ radial distribution with’5’ digital ammeter and one voltmeter with variable power supply.(0-100V, 2 Amp.)

01

Page 21: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

Requirement of switchgear & protection lab.

S.No. Name of Equipment Specification Qty.1. Panel for the time characteristic of MCB &

FUSE The operation of MCB & FUSE can be studied on this panel.The different readings are obtained by changing the load current .The accurate time- current characteristic be obtained for inverse time o/c relay with the help of digital timer and digital ammeter. The semaphores are used for indication weather the circuit is connected or not .The control circuit is fully automatic.The students are required only to connect the load.

01

2. Simulation model of distance protection of transmission lines

Designed with MCB & HRC fuses used to detect fault current at a distance and to isolate the transmission lines from power supply.

01

3. P.T. Testing kit by comparison V.G. as Null Detecter-Measurement of % ration error and phase angle of any given P.T. : Potential Transformer test set-Measurement of ration error +/- 10% Phase angle error +/- 400 minutes with 110V.Accessories :

a) Potential Transformer class 0.2 (6 ranges )/110 V.

b) A.C.Null Detecterc) UPF PT Burden box :5VA to

105 VA/110Voltsd) Commercial PTs 440 V

/110V, 1100 V/110 V

01

01

0101

02

Page 22: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

Mechanical Engg Deptt.

CAD/CNC Laboratory

S.No. Name of the item Qty Specifications

01 Colour Printer 01 Colour printer with tanks, size A-4, wi-fi,

Make: Canon, Brother, HP02. Laser Printer 02 Laser Printer (Mono) Connectivity with Microsoft

Windows 7, Windows Vista, Windows XP, Windows Server 2003, Windows Server 2008.Make: Canon, Brother, HP.

03 Computer Systems 10 Desktop PC

i. CPU: Intel Core i7-2600 or Higher (3.4 GHz, 8 MB Cache or better or Higher, 4 cores).

ii. Chipset: Intel Q67 Express or higher.iii. Memory Slots: 4 DIMMiv. Memory: 8 GB 1333 MHz DDR3 SDRAM v. Hard Disk Drive: 1 TB.vi. Optical Drive-SATA Super Multi DVD writer.vii. Monitor: 47 cm (18.5 inch) larger LED Digital

Colour Monitor TCO- 05 certified.viii. Mouse: Optical with USB interface.ix. Ports: 6 USB Ports (with at least 2 in front), audio

ports for microphone and headphone in front.x. Graphics: Integrated Intel HDxi. Network Interface: Integrated Intel 82579LM

Gigabit Ethernet, Intel Pro 1000CT Gigabit 802.11b/g/n wireless.

xii. Operating System: Windows 7 Professional Preloaded with Media and Documentation and Certificate of Authenticity.

xiii. OS Certifications: Windows 7 OS and Linux certification.

xiv. Audio: Realtek ALC261 high definition audio codec (all ports are stereo).

xv. Preloaded Software: Pre- installed Intel software Protect Tools security Suite, Software Management Agent, Comp trace for Desktops agent, Vision Diagnostics, PDF complete corporate Edition, Microsoft Office, Norton or McAfee or e-Scan or Trend Micro or Quick Heal Antivirus (Latest Version) with 1 Year License.

xvi. In built Wi-fi card xvii. In built Speakers

04 UPS 10 800 VA Off Line with 60 Mins Backup

Page 23: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

Material Science Laboratory

S.No Name of Equipment Tech- Specifications

1 Monocular Metallurgical Microscope model-56,Metzar Make complete with 2 eye piece,5x8x10

2 Metallurgical Binocular microscope Model-MM3 with imported 100X oil immersion

3 Trinocular microscope model MM4 same as MM3 but with Trinocular head complete

4 Transformer for monocular metallurgical microscope

5 Hair Dryer

6 Monocular microscope Eye-piece Metzer 5X,10X

7 Metallurgical Binocular microcope, eye piece 15X,10X

8 Inverted Binocular microcope, eye piece 15X,10X

9 Trinocular microscope Eye piece 15X,10X

10 Liquid polishing Machine

11 Sample mounted press • Transformer (SMP)

Jack Rod12 Belt grinder with O.S.H.P single Phase

motor13 Wheel grinder 3 Phase with Starter

14 Dye penetrating Testing by spraying

15 Flaw Detecting Machine

16 Ultrasonic Machine

Fluid Mechanics Laboratory

Equipment Name Technical Specifications

1. Pelton WheelTurbine

Power :-1HPSpeed:-1000RPMDischarge;-200lt/mWater Circulation:- Pump Coupled With 5HP motor Operating at 3Phase,50Cycles,400Volts, Flow Unit-Venturimeter and double Column Manometer

Page 24: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

2. Francis Turbine Output power = 5HP/3.75 KWDischarge=2000LpmHead =15mSpeed=1250RPMSump Tank=700 liters(Approximately)Water Circulation= Supply Pump Coupled with 15HP motor operating on3 Phase,50 Cycles,400VFlow Unit- Venturimeter and U- tube ManometerMaterial= Mild Steel with FPR Coated

3. Hydraulic Ram Test Rig Make=DD(I)Size=5cmx2.5cm Drive=5HP motor ,3 Phase,50 Cycles,400/440 Volts with Multi-speed mechanism.

4. Impact of Jet of Vanes Make=(DD(I)G.M Nozzles: 10Straight Taper 2)Curved TaperG.M Vanes:1) Circular Vane of 1800 deflection2) Curved Vane of 1350 deflection3) Horizontal Vane of 900deflection

5. Meta centric height of ship Model Apparatus

6. Bernoulis Apparatus

7. Pipe friction Apparatus

8. Reynolds Apparatus

Thermal & Automobile Engineering Laboratory

S.No Name of Equipment Tech. Specifications

1. Air Conditioning Test Rig 1.5 T Capacity with capillary, Air compressor (Kirloskar) with SKW Stabilizer

2. Refrigeration Test Rig 1/3 Hp Compressor,25lt Evaporator Capacity, Capillary Tube with Stabliser

3. Vapor Absorption Refrigeration Set up Heater,Condenser,Evaporator with digital Temp. Sensors.

4. Air Compressors Two Stage Air Compressor, Air Drum ,Temp.Sensors,Pressure Gauges and Energy meters.

5. Bomb Calorimeter Bomb,Oxygen,Cylinder, Wt.Box, Pressure Crucible, Digital Temp. Indicator with Printer

6. ORSAT 9HS Analyzer Wooden Box Consists of Four tubes consists of Different acids.

Page 25: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

7. Boiler /Steam Turbine Test Rig Capacity,600kg/hr,15kg/cm2,Monitory Accessories Coupled with 3KW steam turbine having pipe line with separating and throttling with Chimney condenser water pump, Fuel Tank Soft Water Tank, Hard water Tank.

8. Separate and Throttling Calorimeter Small Boiler,Temp Indicator, Pressure Gauge Condenser with motor,SHP

9. Bearing condition monitoring equipment

10. Wear debris analyzer

11. Engine Analyser, debris oil analyser, Oil element Analyser

ENGG METROLOGY Lab

1. Combination Square Set-S Range: 12”(300mm) Mitutoyo(Japan)

2. Digimatic Calipers, Range-0-300mm,L.C-0.01mm,Accuracy±0.0015”,Make-Mitutoyo(Japan)

3. Digital Counter Type Dial Height Gauges Range-0-300mm,L.C-0.01mm, Accuracy-±0.03mm,Make-Mitutoyo(Japan)

4. Dial Indicator Range-10mm,L.C-0.01mm, Accuracy-+0.03um,Make-Mitutoyo(Japan)

5. Gear Tooth Caliper Range-1-26mm

6. Granite Surface plate, Grade-“O” with calibration Certificate Size-630mmX630mmMake-JAFUJI(Germany)

7. Mechanical Comparators with suitable stand L.C-0.001 mmMake-Mahar(Germany)

8. Metric Rectangular Gauge Block Sets Base 1mm,Grade-1” Steel(87pcs) Make- Make-Mitutoyo(Japan)

9. Magnetic base Make-JAFUJI(Germany)

10. Magnetic Stand with fine Adjustment. Make-JAFUJI(Germany)

11. Outside Micrometer, Range-0-25mmL.C-0.01mm Mitutoyo(Japan)

12. Precision Spirit level- Size 150X0.02mm MeterMake-Mahar(Germany)

13. Radius Gauge Range-1-10mmMake-Mahar(Germany)

14. Radius Gauge Range-10-25mm

Page 26: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

15. Sine bar Range-200mm

16. Steel Scale Size-300mm(12”) Make-Crystal

17. Steel Tape(3m) Make-BIS/IS Mark

18. Tubular Inside Micrometer Range-50-150mmL.C-0.01mm Make-Mitutoyo(Japan)

19. Universal bevel Protector Range-150-300mmL.C-5 inch (0o-900-00) Make-Mitutoyo(Japan)

20. Vernier Caliper Range-0-30mm,L.C-0.02mm,Accuracy-±0.04mm Make-Mitutoyo (Japan)

21. Vernier Height Gauge Range-0-30mmL.C-0.02mm Accuracy-±0.03mm Make-Mitutoyo(Japan)

22. Vernier Depth Gauge Range-0-200mmL.C-0.02mm Accuracy-±0.03mm Make-Mitutoyo(Japan)

23. U-Block hardened with Clamp. Size-100X80X80mm Make-JAFUJI(Germany)

Industrial Engineering Lab

1. Vibration meter/ Vibration Analyser/Data Collector (Single Multi channel)

2. Infrared Camera (Thermal Imager) for Industrial Application (upto 2000 0C)

3. Hand Arm and Whole Body Vibration Analyser

4. Laser Alignment System

5. Acoustic Analyser

6. Software for condition monitoring/ vibration analyses

7. Wireless vibration monitoring system

8. Ultrasonic leak detection system

Page 27: FLUID MECHANICS Laboratory - Jammugcetjammu.org.in/tender/list_of_equipments.docx  · Web viewImportant Term & Condition : The firm submitting downloaded tender documents from the

PHYSICS LAB

Equipment for Lab;-

1. Four Probe resistivity Measurement Sk012 02No’s2. Radiation Counter SN615 02No’s3. Planck’s Constant by LED Sk014 02No’s4. Balmer Series and Rydberg Constant Sk093/Sk062 02No’s5. Extension Board 06No’s6. Stabilizer 5Kva 01No’s


Recommended