fluidionSAS-231RueSaint-Honoré-75001Paris,France
Contactus:Email:[email protected] fluidion(HQParis,France) fluidion(LosAngeles,USA))+33182390290 )+1(626)765-5580
www.fluidion.com
Aminiaturizedmobilemicrobiologylab TheALERTLABfromfluidion isauniqueanalyzercapableofautomaticprocessingand measurement of a manually collected fluid sample, performing automaticincubation, optical monitoring (multispectral absorbance and fluorescence) andwirelessdatatransmission,andenablingrapidbacterialenumeration.TheALERTLABgreatlysimplifiesmeasurementlogistics,eliminatestheneedforsamplerefrigerationduring transportation prior to standard laboratory measurements, and minimizeserrorsduetosampledegradationbetweencollectionandmeasurement.
On-demandanalysisinthefield,on-the-go,orinalabThe ALERT LAB can be used in a variety of settings for quantifying E. coli, TotalColiformsorEnterococcipresenceinlakes,rivers,coastalwater,catchmentsitesorinwater treatmentplants. It canoperateon rechargeablebatteries at a remote fieldlocation, or powered via vehicle’s power on-the-go, or plugged into an electricaloutlet in a laboratory setting. Capable of carrying out six measurements on abattery charge, full water quality monitoring at remote field locations isconsiderablysimplifiedwhileminimizingcostandtime-to-result.ThemobileALERTLAB is extremely portable and fully operational out of the box. The maintenanceprocedureisquick(lessthan5minutes)andfieldcalibrationisnormallynotrequired.A floating version is also available (ALERTSystem),which canbe installeddirectly insideawater tankor floatingonsurface water, thus eliminating the need for expensive infrastructure (piping, pumps, solar panels, cabinets,communicationequipmentetc.).
AfastandreliableresponseTheALERTLABprovidesaquantifiedresponseintermsofbacteria/100mLpresentinthesampledwater.Thesystemimplementsfluidion’smultispectralopticaldetectiontechnology,whichensuresconsistentmeasurementseverytimeandfasttime-to-result.Triggeredviaamobilephone,theanalyzermeasuresawiderangeofconcentrationsandcansendoutautomaticalertsifthethresholdisexceededinordertoenablegreateroperatorresponsiveness.
FLUIDIONALERTLAB(PORTABLEANALYZER)Theautonomousmicrobiologymobileanalysislab
fluidion introduces the ALERT LAB, a fully portable, autonomous and remotely-controllable analyzer for themeasurementofE. coli andotherbacteria. Suitable for sourcewaterandenvironmentalmonitoringata fieldlocation,inamovingvehicle,orinalab,itperformssixmeasurementsusinga12VDCpowersourceorbattery.TheALERTLABenablesrapidbacterialenumerationimmediatelyfollowingwatersamplingbyfieldpersonnel.
fluidion SAS is a high-technology company that designs and manufactures innovative sample collection andchemical/microbiological in-line analysis instruments for water quality monitoring and environmentalapplications.Thecoretechnologyreliesonfluidion’sproprietarypatentedfluidicsystems.
fluidionSAS-231RueSaint-Honoré-75001Paris,France
Contactus:Email:[email protected] fluidion(HQParis,France) fluidion(LosAngeles,USA))+33182390290 )+1(626)765-5580
www.fluidion.com
TECHNICALSPECIFICATIONSDimensions 10.2”X9.6”X6.6” Totalmeasurements 6percharge
Weight 8lbs Responsetime 1h–14h
Measurementtrigger On-demand Environmentalconditions 0oC-40oC
ParametersE.coli,Totalcoliforms
OREnteroccociCommunication GSM,USB,secureweb
Measurementrange 4CFU–5×105CFU/100mL Antenna Internal/External(opt.)
MaterialsPMMA,PVC,
Acetal,SST316LPowersource
LiIonbattery,ACpower,carlightersocket
ALERTcellphoneandwebinterface
TheALERTLABusesawirelesscommunicationprotocolbasedontheGSMnetworkforbothsystemconfigurationanddatamanagement.Alternatively, thesystemcanoperateon long-range radionetworksusing theLoRaWANprotocol(optional).ThesystemcanbefullyconfiguredfromanoperatorcellphoneusingintuitiveSMS-basedcommands,andcan generate cell phone alerts. Real-time data is sent via theGSMnetwork/LoRaWAN to a telecomm server,whichpushes data to the fluidion cloud-based data management and visualization server (server installation in clientdatacenterisapossibleoption).IncasethereisnocellcoverageintheinstallationareaandLoRaWANisnotinstalled,the systemcanbepre-configured fromaPCvia theUSB interface,anddatacanbe sentvia serialprotocols suchasRS232(optional).