IEEE 802.3cg Task ForceApril 11, 2018 Page 1 Version 1.0 Jay Cordaro Broadcom Inc. Follow-up to 10BASE-T1S Immunity Measurements April 11, 2018
Transcript
Page 1: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

IEEE 8023cg Task Forcendash April 11 2018 Page 1 Version 10

Jay Cordaro

Broadcom Inc

Follow-up to 10BASE-T1S Immunity

Measurements

April 11 2018

Page 2 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 2

Contributors

bull Ahmad Chini

bull Mehmet Tazebay

Page 3 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 3

bull This presentation responds to presentation [1] from Ivanov et al and is a follow-up to Broadcom presentation [2] on noise

bull 10BASE-T uses Manchester Encoding to transmit 5Vpk-pk (nominal)

bull 10BASE-T1S uses Differential Manchester Encoding (DME) to transmit 1Vpk-pk^ ‒ Less transmit swing than 10BASE-T and much higher noise environment

bull Revisit noise topic again using Bulk Current Injection (BCI) clamp method[3]

Objectives and Motivation

^ TX Voltage currently TBD in 147531

DME vs 8023 Manchester Encoding (x-axis not to scale)

Page 4 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 4

BCI Test Motivation

bull Examine the feasibility of implementation of 10BASE-T1S for multidrop automotive

configurations

bull Investigate possible immunity-related problems

bull Worst-case EMI-coupling clamp locations are different from testing strictly to ISO 11452-4

ndash Strong resonances will be seen at other clamp locations

bull Long harnesses exhibit in-band resonances at lower frequencies than a 2m cable

bull If a problem does not show at standard clamp locations it does not mean they do not exist

Must design systems with margin to handle realistic worst-case conditions

Page 5 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 5

Difficulties with Measurement

bull Conversion ndash Peaks at 15 amp 30MHz wo termination in [2] were real but noise radiated out from amp connector

ndash 100BASE-T1 CMC doesnrsquot have good common to common rejection at low frequency (-20dB)

ndash scope converted large common mode voltage to differential noise at 1MHz

Eliminate sources of conversion

ndash Use well-shielded differential probe with large CMRR 1MHz (Tektronix P6247)

ndash Solder short connection directly to PHY-side of CMC

ndash Use coax with low leakage at test frequencies

ndash Add ferrites Sniff with spectrum analyzer for clean environment with test running

bull Termination ndash different schemes possible Each has tradeoffs

Utilize termination scheme similar to [1] (except CM term of 250Ω and DM term 1KΩ -- no moat on board)

bull All test setup details available on request

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 2: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 2 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 2

Contributors

bull Ahmad Chini

bull Mehmet Tazebay

Page 3 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 3

bull This presentation responds to presentation [1] from Ivanov et al and is a follow-up to Broadcom presentation [2] on noise

bull 10BASE-T uses Manchester Encoding to transmit 5Vpk-pk (nominal)

bull 10BASE-T1S uses Differential Manchester Encoding (DME) to transmit 1Vpk-pk^ ‒ Less transmit swing than 10BASE-T and much higher noise environment

bull Revisit noise topic again using Bulk Current Injection (BCI) clamp method[3]

Objectives and Motivation

^ TX Voltage currently TBD in 147531

DME vs 8023 Manchester Encoding (x-axis not to scale)

Page 4 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 4

BCI Test Motivation

bull Examine the feasibility of implementation of 10BASE-T1S for multidrop automotive

configurations

bull Investigate possible immunity-related problems

bull Worst-case EMI-coupling clamp locations are different from testing strictly to ISO 11452-4

ndash Strong resonances will be seen at other clamp locations

bull Long harnesses exhibit in-band resonances at lower frequencies than a 2m cable

bull If a problem does not show at standard clamp locations it does not mean they do not exist

Must design systems with margin to handle realistic worst-case conditions

Page 5 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 5

Difficulties with Measurement

bull Conversion ndash Peaks at 15 amp 30MHz wo termination in [2] were real but noise radiated out from amp connector

ndash 100BASE-T1 CMC doesnrsquot have good common to common rejection at low frequency (-20dB)

ndash scope converted large common mode voltage to differential noise at 1MHz

Eliminate sources of conversion

ndash Use well-shielded differential probe with large CMRR 1MHz (Tektronix P6247)

ndash Solder short connection directly to PHY-side of CMC

ndash Use coax with low leakage at test frequencies

ndash Add ferrites Sniff with spectrum analyzer for clean environment with test running

bull Termination ndash different schemes possible Each has tradeoffs

Utilize termination scheme similar to [1] (except CM term of 250Ω and DM term 1KΩ -- no moat on board)

bull All test setup details available on request

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 3: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 3 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 3

bull This presentation responds to presentation [1] from Ivanov et al and is a follow-up to Broadcom presentation [2] on noise

bull 10BASE-T uses Manchester Encoding to transmit 5Vpk-pk (nominal)

bull 10BASE-T1S uses Differential Manchester Encoding (DME) to transmit 1Vpk-pk^ ‒ Less transmit swing than 10BASE-T and much higher noise environment

bull Revisit noise topic again using Bulk Current Injection (BCI) clamp method[3]

Objectives and Motivation

^ TX Voltage currently TBD in 147531

DME vs 8023 Manchester Encoding (x-axis not to scale)

Page 4 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 4

BCI Test Motivation

bull Examine the feasibility of implementation of 10BASE-T1S for multidrop automotive

configurations

bull Investigate possible immunity-related problems

bull Worst-case EMI-coupling clamp locations are different from testing strictly to ISO 11452-4

ndash Strong resonances will be seen at other clamp locations

bull Long harnesses exhibit in-band resonances at lower frequencies than a 2m cable

bull If a problem does not show at standard clamp locations it does not mean they do not exist

Must design systems with margin to handle realistic worst-case conditions

Page 5 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 5

Difficulties with Measurement

bull Conversion ndash Peaks at 15 amp 30MHz wo termination in [2] were real but noise radiated out from amp connector

ndash 100BASE-T1 CMC doesnrsquot have good common to common rejection at low frequency (-20dB)

ndash scope converted large common mode voltage to differential noise at 1MHz

Eliminate sources of conversion

ndash Use well-shielded differential probe with large CMRR 1MHz (Tektronix P6247)

ndash Solder short connection directly to PHY-side of CMC

ndash Use coax with low leakage at test frequencies

ndash Add ferrites Sniff with spectrum analyzer for clean environment with test running

bull Termination ndash different schemes possible Each has tradeoffs

Utilize termination scheme similar to [1] (except CM term of 250Ω and DM term 1KΩ -- no moat on board)

bull All test setup details available on request

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 4: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 4 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 4

BCI Test Motivation

bull Examine the feasibility of implementation of 10BASE-T1S for multidrop automotive

configurations

bull Investigate possible immunity-related problems

bull Worst-case EMI-coupling clamp locations are different from testing strictly to ISO 11452-4

ndash Strong resonances will be seen at other clamp locations

bull Long harnesses exhibit in-band resonances at lower frequencies than a 2m cable

bull If a problem does not show at standard clamp locations it does not mean they do not exist

Must design systems with margin to handle realistic worst-case conditions

Page 5 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 5

Difficulties with Measurement

bull Conversion ndash Peaks at 15 amp 30MHz wo termination in [2] were real but noise radiated out from amp connector

ndash 100BASE-T1 CMC doesnrsquot have good common to common rejection at low frequency (-20dB)

ndash scope converted large common mode voltage to differential noise at 1MHz

Eliminate sources of conversion

ndash Use well-shielded differential probe with large CMRR 1MHz (Tektronix P6247)

ndash Solder short connection directly to PHY-side of CMC

ndash Use coax with low leakage at test frequencies

ndash Add ferrites Sniff with spectrum analyzer for clean environment with test running

bull Termination ndash different schemes possible Each has tradeoffs

Utilize termination scheme similar to [1] (except CM term of 250Ω and DM term 1KΩ -- no moat on board)

bull All test setup details available on request

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 5: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 5 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 5

Difficulties with Measurement

bull Conversion ndash Peaks at 15 amp 30MHz wo termination in [2] were real but noise radiated out from amp connector

ndash 100BASE-T1 CMC doesnrsquot have good common to common rejection at low frequency (-20dB)

ndash scope converted large common mode voltage to differential noise at 1MHz

Eliminate sources of conversion

ndash Use well-shielded differential probe with large CMRR 1MHz (Tektronix P6247)

ndash Solder short connection directly to PHY-side of CMC

ndash Use coax with low leakage at test frequencies

ndash Add ferrites Sniff with spectrum analyzer for clean environment with test running

bull Termination ndash different schemes possible Each has tradeoffs

Utilize termination scheme similar to [1] (except CM term of 250Ω and DM term 1KΩ -- no moat on board)

bull All test setup details available on request

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 6: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 6 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 6

Test Setup bull 100BASE-T1 CMCs at each signal node CM termination 250Ω to gnd (L0) before CMC

bull 100BASE-T1 cables (26 AWG) in passive linear topology ldquominrdquo from [4] 5cm above gnd plane (10cm stubs)

bull 100BASE-T1-quality connectors

bull Solder short 2pin connector directly on CMC for noise measurement Attach differential probe

bull Sniff cable from power amplifier to BCI clamp for any emissions check connectors Add ferrites

bull Injection calibrated for 200mA RMS flat level vs frequency

bull Grounding test conditions

BCI

CLAMP

10

cm

10cm

A

Signal

Generator Power

Amplifier Real time scope

Probe

power

supply ferrites

Tek P6247

Diff probe

ferrites

50

Ω C

on

n 50

Ω

10cm

50

Ω C

on

n 50

Ω

500Ω (2x1K in ||) (01 match) to

L0 term on line side of CMC

250Ω CM term 1KΩ DM term on

each signal node 25K Ω to L0 termination (05

matching) on PHY side of CMC

to protect probe input

-- Grounded all board L0 connected to gnd plane

-- Floating boards L0 floating 5cm above gnd plane not connected to gnd plane

Measurement using

differential probe

H A

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 7: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 7 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 7

DM noise Board Ground Connected to Ground Plane

bull DM noise greatly reduced especially 1MHz ndash due to high CMRR of differential probe

bull Note different noise levels at different nodes of the multi-drop configuration

Note L0 = Board Ground

Test Configuration

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 8: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 8 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 8

DM Noise Board Ground Floating Above Ground Plane

bull Different clamp location (approx 1500mm) from node H all nodes floating

Note L0 = Board Ground

Test Configuration

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 9: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 9 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 9

Mode Conversion

bull Mode conversion plotted for the tested cable harness and 14763 limit

ndash All CMCs removed harness 5cm above ground plane common-mode impedance set to 250Ω on both sides

ndash Clause 147 does not specify setup for common mode impedance for mode conversion

bull Noise measurements need to be scaled considering the mode conversion of the cable harness

Mode Conversion Harness Measurement

Using VNA

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 10: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 10 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 10

Scaled DM Noise on Cable Harness

bull Above numbers are for 200mA BCI test level additional scaling should be done for

customers requiring 355mA test level (15-30 MHz band)

bull Based on this data 500mVpk-pk (178mVRMS) CW NBI seems like a reasonable design goal

1667 MHz 33 MHz 50 MHz

Node Board L0 connected to ground plane measured DM Noise mV 50 100 80

Node Board L0 Floating 5cm above ground plane measured DM Noise

mV 105 194 132

Mode Conversion Limit -430dB -386dB -350dB

Measured Mode Conversion -51dB -46dB -44dB

DM Scaling Factor 8dB 7dB 9dB

Node Board Grounded Scaled DM Noise mV 126 224 225

Node Board Floating Scaled DM Noise mV 263 434 372

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 11: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 11 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 11

Summary

bull Noise measurements presented with improved measurement setup and common-mode

termination

bull CM-DM conversion of 100BASE-T1-based cable harness measured better than 14763

limit

bull Mode conversion data for components is essential in investigating the noise level

bull Differential Narrow-Band Interference is a concern for 10BASE-T1S

bull A robust preamble is essential to improve system performance

bull Use 500mVpk-pk (178mVRMS) CW NBI added as basis for comparing preambles amp BEACONs

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You

Page 12: Follow-up to 10BASE-T1S Immunity Measurements …grouper.ieee.org/groups/802/3/cg/public/adhoc/cordaro_3...Version 1.0 IEEE 802.3cg Task Force– April 11, 2018 Page 1 Jay Cordaro

Page 12 IEEE P8023 Maintenance report ndash July 2008 Plenary Version 10 IEEE 8023cg Task Forcendash April 11 2018 Version 10 Page 12

References

[1] ldquoEvaluation of Immunity Aspects in Multidrop Channelsrdquo Ivanov et al

httpwwwieee802org3cgpublicadhocIvanov_8023cg_Evaluation_of_Immunity_Aspects_in

_Multidrop_Channelspdf

[2] ldquoImmunity Measurements and Considerations for 10BASE-T1Sldquo Cordaro et al

httpwwwieee802org3cgpublicadhoccordaro_8023cg_Immunity_Measurements_and_Con

siderations_for_10BASE-T1Spdf

[3] ldquoA Review of Automotive EMC Environment amp Testsrdquo Buntz amp Tazebay pp 26-28

httpwwwieee802org3bwpublicbuntz_tazebay_3bw_01_0914pdf

[4] ldquo10SPE automotive PHY multidrop topology proposalsrdquo Buntz

httpwwwieee802org3cgpublicadhocbuntz_10SPE_05b_0329pdf

IEEE 8023cg Task Forcendash April 11 2018 Page 13 Version 10

Thank You