DRYWALL Framing Systems
for Framing in:
• Condominiums
• Apartments
• Residences
• Dormitories
• Barracks
• Town Homes
• Rest Rooms
• Motels
• Hotels
• Villas
• Suites
Now includes walls.
T E C H N I C A L G U I D E DrywallFramingSystem
Between us, ideas become reality.®
CEILING&WALL SYSTEMS
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 1
2
DrywallFramingSystem ShortSpan™ Framing System for Interior Drywall Ceilings
For more information call 1 877 ARMSTRONG
ShortSpan Framing Tees: are engineered for faster, easier installation
ShortSpan Framing and Locking Angle Molding make drywall framing faster and easier
Corridor framing using traditional steel studs
Rotary stitch
Knurled surface
Screwstop(prevents screw
slippage)
Crimped area(for easy application
of Strongback)
2ʺ
1-1/4″
ShortSpan System: The best choice for framing short spans
Reduce Labor Cost: eliminates screws, cross tees and hanger wire (in most applications)Reduce Material Cost: economical price point on componentsReduce Waste: standard and custom lengths – and there’s no cartons to throw awayReduce Risk: system was evaluated using full scale seismic testing and may be an acceptable solutionon your next project. Check with your local code official for approval prior to installations. For officialtest reports, please contact TechLine at 877-ARMSTRONG.Fire Rated: up to 2-hour rating with one (1) layer of fire-rated gypsum board. (See Pages 5 and 6 fordrawing detail) Resistive when used in applicable UL fire resistive designs. Fire Guard componentsmeet UL Design Listings D501, D502, G523, G524, G526, G527, G528, G529, G531, G553, J502, L502,L508, L513, L515, L525, L526, L529, L564, P501, P506, P507, P508, P509, P510, P513, P514.
✓ 1-1/2″ wide face exceeds the minimum industry standard (double web)
✓ ScrewStop™ reverse hem prevents screw spin off
✓ Balanced profile stays flat during installation
✓ Rotary stitching on double web adds strengthand stability
✓ Deep knurled surface for easy screw insertion
✓ G40, .018″ metal thickness meets ASTM C645
Traditional method to frame short spans
No Cardboard Cartons
✓ Reduced clean-up andwaste at jobsite
✓ Quick to open
✓ Store outside
✓ Chop saw to length
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 2
For more information call 1 877 ARMSTRONG3
DrywallFramingSystemLocking Angle Molding
Locking Angle Molding (Patent Pending): a faster, more accurate solution
✓ Pre-engineered locking tabs punched 8″ oncenter:
– Eliminate measuring 16″ or 24″ – Locking tabs prevent lateral and upward
movement – Eliminate screws, pop rivets, or crimpers
needed to attach tees to molding
✓ Knurled surface on both flanges
✓ ScrewStop reverse hem prevents screw spinoff and provides safer handling
✓ Alignment crimp at locking tabs for fast, easy alignment
✓ Locking Angle Molding is designed to only work with Armstrong ShortSpan products
ShortSpan tee engaged in Locking Angle Molding
AlignmentCrimp
“A”“B”
Cut tee to within 1/8ʺ of the walls to fully engage into lock
KnurledSurface
ScrewStop
GypsumBoard
Laser Alignment
Steel Studs
LockingMechanism
Installation Notes
1 ShortSpan tees must be cut within 1/8″ of the vertical leg ofthe Locking Angle Moldings (for non-rated installations only.)
2 Must screw LAM-12 and KAM-12to wall structure (#8 x 1-1/4″ waferhead self drill sheet metal screwstested in 25 and 20 gauge steelstuds)
– Assembly tested to 200 lbs. forshear and screw pullout withoutfailure (refer to Maximum Loadchart on page 11)
3 Insert right hand flange of tee intopocket “A” first and allow leftflange to clear pocket “B” andrest on angle molding. Slide tee tothe left to engage in pocket “B”(audible click)
No AdditionalRequirements For Seismic AreasThere’s no need to screwShortSpan Tees to LockingAngle Molding in SeismicDesign Categories A-F(unless required by local code)
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 3
4
ShortSpan™ StrongBack™ Support
For more information call 1 877 ARMSTRONG
DrywallFramingSystem
StrongBack (Patent Pending): Easier, pre-engineered solution to support spansover 6 or 7 feet
✓ Knockouts 8″ on center eliminates measuring, screwing,and splicing
✓ Allows vertical supports at 4′on center instead of 24″ or 16″
✓ Reduces lateral movement
✓ Resists upward movement if used with vertical tee post or stud
✓ Easier to level system comparedto traditional framing
StrongBack support installed mid-spanwith vertical post at 4′ on center.
1 Flattened bulballows StrongBackto slide over bulb
2 Slide StrongBack into place – no bending oftab required
Installation Recommendations*
1 Install Locking Angle Molding (LAM-12) on walls
2 Lock in ShortSpan tees(S77XX) into LAM-12
3 Open StrongBack (SB-12) lock tabs with pliers (easier ifperformed on floor)
4 Slide StrongBack over bulb ofShortSpan tee and engage bybending lock tabs back to original position
5 Support and level system tostructure; attach vertical supportsto StrongBack as required
6 To provide stability to StrongBack it is recommended to bend first 4″ to 90° and pin to wall
*Alternative Method to Install StrongBack
ScrewFasten
Strongback
Strongback
Tee
300# Pull OutCut and Screw
1-1/2"3"
Hanger Wire
Main Beam
300# Pull Out
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 4
5
DrywallFramingSystem
For more information call 1 877 ARMSTRONG
Fire Rated ShortSpan™
Fire Rated ShortSpan
Fire-Rated 5/8" Gypsum Board
LAM-12Angle Mold(or PRLAM12)
Wall
3/8" Space From Wall (Can use wood shims to center)
ShortSpan Tee (Do not screw Tee to LAM-12)
24"
16"
8"
8"
Fire-Rated 5/8" Gypsum Board Block on Joint
LAM-12 Angle Mold
(or PRLAM12)
14´ or less
24"
16"
ShortSpan Tee Spacing With 8' Long Fire-Rated 5/8" Gypsum Board
12 Gauge Wire 48" o.c.
Fire-Rated 5/8" Gypsum Board Attached to ShortSpan Tee
StrongBack SB-12 Support Bar
ShortSpan Tee
SB-12, 50" o.c. Max.
Fire Rated: up to 2-hour rating with one (1) layer of fire-rated gypsum board. Resistivewhen used in applicable UL fire resistive designs. Fire Guard components meet UL DesignListings D501, D502, G523, G524, G526, G527, G528, G529, G531, G553, J502, L502, L508,L513, L515, L525, L526, L529, L564, P501, P506, P507, P508, P509, P510, P513, P514.
* Control Joints per ASTM C840. For details contact Tech-Line at 877-276-7876.
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 5
6
Fire Rated ShortSpan™
For more information call 1 877 ARMSTRONG
DrywallFramingSystem
Fire Rated ShortSpan
Fire Rated: up to 2-hour rating with one (1) layer of fire-rated gypsum board. Resistivewhen used in applicable UL fire resistive designs. Fire Guard components meet UL DesignListings D501, D502, G523, G524, G526, G527, G528, G529, G531, G553, J502, L502, L508,L513, L515, L525, L526, L529, L564, P501, P506, P507, P508, P509, P510, P513, P514.
Lam-12
ShortspanTee
Strongback
3/8"
Overlap on tee
Fire rated gypsum boardBlock on joint
Fire rated gypsum boardBlock on joint
Strongback
Shortspan tee
24"
24"
16"
8"
16"
Note: For complete installation detailsSee specific UL designs.
Space 12-3/8 " From wall(Can use wood shim to center)
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 6
DrywallFramingSystemQuikStix™ Drywall Ceilings – Locking Pocket Mains
For more information call 1 877 ARMSTRONG7
✓ Uptight clip allows installation in 1-1/2″ to 5-1/2″ plenums
✓ Locking Pocket Main has the same characteristics as a Strongback
✓ Locking Pocket Main allows uptight installation because installed at same level as ShortSpan tees
✓ ShortSpan Tees can span up to 7′ without vertical support (16″ o.c.)
✓ Locking Angle Mold eliminates measuring, marking and screwing at perimeters
QuikStix™ Drywall Ceilings Locking Pocket Mains (Patent Pending): Reducestime and labor installing drywall ceilings in tight plenum conditions.
16˝
16˝
16˝
16˝
16˝
16˝
QSUTC Clip 4´ o.c. Along Main
WallWall
1/2˝ or 5/8˝ Gypsum Board
7´ or less
7´ or less
LAM-12 ScrewedInto Wall Stud
LAM12 Locking Angle Mold Screwed into Wall Stud
QSLPM12 LockingPocket Main
Pan Head Screw (Every 4th ShortSpan Tee To Locking Pocket Main orcrimp every one)
Note:
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
14´ or less
Note:
Locking PocketMain Splice
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
Installation Recommendations
1 Vertical Supports to structure should be eitherQuikStix Uptight Clips or stifflegs using scrap metal. Wireis NOT recommended forhanging this system.
2 ShortSpan tees must be cut within 1/8″ of vertical leg ofthe Locking Angle Moldingsand Locking Pocket Mains.
3 To engage ShortSpan teesinto Locking Pockets: insertright hand flange of tee intolong pocket first and allow leftflange to clear short pocketand rest flat. Slide tee to theleft to engage in short pocket(audible click)
16”
16”
16”
16”
SSLMT-1214’ o.c.
UTC Clip 16” o.c.
SS-771416” o.c.
Wall
5/8” Gypsum Board
QSUTC ClipAdjustable inHeight
QSUTC ClipAdjustable inHeight
QSUTC ClipAdjustable inHeight
STRUCTURE
4-1/2"
"2/1-4
"2/1-1
Pre-Bent Clip
Pan Head Screw Hole
1-1/2"
"2/1-1Reverse Clip foruptight conditions
Pan Head Screw
1/4"
Most Gap
Most Gap
Least Gap
Least Gap and Mid Gap
Mid Gap
Uptight Clip (QSUTC): Saves time in tight plenum areas and is adjustable to uneven surfaces
1-3/4"
Main Beam o.c. Spacing
VerticalSupport
(Tee Post orQSUTC)
Spacing Along Main Beam
ShortSpan Tee Spacing
Max Load in Lbs/SF
QSLPM12 - 4' o.c. 4' 16" 5.41 Lb. Sq. Ft.
QSLPM12 - 4' o.c. 4' 24" 5.41 Lb. Sq. Ft.
QSLPM12 - 5' o.c. 4' 16" 4.32 Lb. Sq. Ft.
QSLPM12 - 5' o.c. 4' 24" 4.32 Lb. Sq. Ft.
QSLPM12 - 6' o.c. 4' 16" 3.61 Lb. Sq. Ft.
QSLPM12 - 6' o.c. 3' 16" 4.67 Lb. Sq. Ft.
QSLPM12 - 6' o.c. 4' 24" 2.75 Lb. Sq. Ft.
QSLPM12 - 7' o.c. 4' 16" 2.86 Lb. Sq. Ft.
QSLPM12 - 7' o.c. 4' 24" 1.71 Lb. Sq. Ft.
Maximum Load in Lbs/SF (L/240 per ASTM C645)
Note: 5/8˝ drywall weighs 2.4 lbs/SF or less 1/2˝ drywall weighs 2.0 lbs/SF or less Fixtures should be independently supported *For other combinations; consult TechLine at 1-877-Armstrong
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:01 PM Page 7
8
ShortSpan™ Corridor SystemDrywallFramingSystem
For more information call 1 877 ARMSTRONG
✓ Eliminates the need for hanger wire and screws
✓ Gussets and mounting rail provide alternative method of grid attachment when straight drops forhanger wire are not possible
✓ Reduced labor costs over conventional installation methods in congested plenum
✓ Alignment crimps at locking tabs for fast, easy alignment
144"
4"
1-3/8"
3/8"
1/4"
144˝
7-5/8˝ or 11-5/8˝
Wall
Support Track
ShortSpanLocking Angle Molding (LAM 12)
Gusset
12′ Locking Angle Molding (LAM12)Wall angle molding fabricated from hot-dipped galvanizedsteel. The molding features patented locking details at 8″centers, that lock and hold the ShortSpan framing tees.
Gusset (LWAGU8) (LWAGU12)The gussets hang on the support rail and extend down to theShortSpan tee that span the space, providing support for theframing system and gypsum ceiling. Gussets are installedevery 16″ as detailed in the system design.
ShortSpan Tee (S7708, S7710, S7712, S7714)ShortSpan eliminates cross tees, screws, and hanger-wire.Rotary stitching on double web adds strength and stability.G40, .018″metal thickness meets ASTM C645.
12′ Support Track (LWAWT12)The support track is 12′ long and is fabricated from hot-dipped galvanized steel. The track provides a perch for theattachment of the gussets.
ShortSpan Corridor System:Time saving solution for congested plenum installations
1-1/4"
1-1/4"
8˝or12˝
8˝or12˝
Gusset Support Track
WallLAM12
ShortSpan
Simple Span
Max Simple Span 6’ 4”
Max Corridor Width 8’ 4”
SIMPLE SPAN MAIN WEB OC Uniform Load at L/240 (Lbs/LF) BEAMS HEIGHT SPACING 4′ 5′ 6′ 7′
S7708, S7710 1-1/2″ 16″ 18.38 9.97 5.51 2.80S7712, S7714
Load Test Data
How to install ShortSpan:1 Must screw LAM-12 to wall structure.
2 ShortSpan tees must be cut within 1/8″ of the vertical leg of theLocking Angle Moldings (for non-rated installations only).
3 Insert right hand flange of tee into pocket “A” first and allow leftflange to clear pocket “B” and rest on angle molding. Slide teeto the left to engage in pocket “B” (audible click).
How to install Support Track:1 Locate the bottom edge of the support track 7-5/8″ for 8″ gusset,
or 11-5/8″ for 12″ gusset, above the horizontal flange of the locking angle molding.
2 Fasten the support tracks to the structure of the wall using fasteners appropriate for the construction. The support track sections have pre-punched holes spaced every 4″ along theirlength to facilitate attachment.
How to install Gussets:1 Hang the ShortSpan Tee on the support track over each end
of every main beam.
2 Insert a #6 x 7/16″ long sheet metal screw through the hole provided in the gusset and into the bulb of the ShortSpan framing tee.
ITEM ITEM O.C. 4′ SPAN 5′ SPAN 6′ SPANNUMBER LENGTH SPACING Lbs./SF Lbs./SF Lbs./SF
S7708 8′ 16″ 18.38
S7708 8′ 24″ 12.25
S7710 10′ 16″ 9.97
S7710 10′ 24″ 6.64
S7712 12′ 16″ 4.87
S7712 12′ 24″ 3.25Note: 5/8″ drywall weighs 2.4 lbs./SF (tees installed 16″ or 24″ on center) – 1/2″ drywall weighs 2.0 lbs/SF (tees installed 16″ on center only)
Maximum Load in Lbs./SF (L/1240)
Rotary stitch
Knurled surface
Screwstop(prevents screw
slippage)
Crimped area(for easy application
of Strongback)
2ʺ
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 8
9
DrywallFramingSystem
For more information call 1 877 ARMSTRONG
Pre-Rock Locking Angle Mold
LockPRLAM-12Locking Angle Molding1-7/8"
View from above
Shortspan Tee(cut to within1/8" of boardor 3/8" of boardfor fire rating
Steel Stud
Pre-rockgypsumboard
Pre-rockgypsumboard
Steel stud
Gypsum boardGypsum board
Weep hole
Shortspan Tee(cab span up to 7'with tees 16" o.c.)
Concrete deck
Gypsum board
PRLAM-12Locking Angle Molding
Shortspan Tee
8" o.c.
Pre-RockMoisture ResistantGypsum Board
5/8" Gypsum Board
Lock
1-7/8"
1-1/4"
PRLAM12 Pre-Rock Locking Angle Mold
Knurled Surface
Crimp Mark
SteelStud
Screw Stop
Weep Hole (Water ShedOpening)
✓ Pre-Engineered locking tabs punched 8″ on center:
– Eliminates measuring 16″ or 24″ – Locking tabs prevent lateral and upward
movement – Eliminates screws, pop rivets, or crimpers needed
to attach tees to molding
✓ Knurled surface on both flanges
✓ ScrewStop reverse hem prevents screw spin offand provides safer handling
✓ Crimp marks at locking tabs for fast, easy alignment
✓ G40 or G90, .018″ metal thickness meets ASTM C645
Pre-Rock Locking Angle Mold (Patent Pending): is a faster, more accuratesolution for two phase Gypsum Board application.
Installation Notes1 Must screw Pre-Rock LAM-12 to wall structure
(#8 wafer head self drill sheet metal screws testedin 25 and 20 gauge steel studs).
2 ShortSpan tees must be cut within 1/8″ of Pre-Rockgypsum board or 3/8″ of board for fire rating.
3 To engage ShortSpan tees into Locking Pockets:insert right hand flange of tee into long pocket firstand allow left flange to clear short pocket and restflat. Slide tee to the left to engage into short pocket(audible click)
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 9
10For more information call 1 877 ARMSTRONG
DrywallFramingSystem Knurled Angle Molding
ScrewStopReverse Hem
Knurling
Pre-PunchedHoles
Knurled Angle Molding (KAM12 & KAM10)More Installation Benefits in Enhanced Drywall Framing System Wall AngleValue Added Features
✓ Knurled Angle Molding (KAM)…for Drywall Framing has the time saving advantages of knurling,ScrewStop™, pre-punched holes, and no cartons to throw away.
✓ Knurling: Helps the screws to grab quickly
✓ ScrewStop: A reverse hem on the top and bottom flange will catch the screw and prevent it from slippingoff the wall angle. It also adds a safety factor…no sharp edges on the top or bottom of the angle.
✓ Pre-punched holes: Located on the top edge, they allow for faster insertion of the screws.
✓ No carton packaging: Eliminate time needed to open and throw away cartons…just cut the plasticstrap and go. They can also be stored outside.
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 10
For more information call 1 877 ARMSTRONG11
DrywallFramingSystemMaximum Load and Vertical Supports
Vertical Support Requirements
Up to 6′ 0″ span No vertical support required
6′ 1″ to 12′ 0″ span Mid-span vertical supportrequired
12′ 1″ to 14′ 0″ span Two vertical supports requiredat 1/3 points (max. 14′ span)
Vertical Support Options
Section Properties – ASTM C754 Table 3
Up to 7′ 0″ span No vertical support required
7′ 1″ to 14′ 0″ span Mid-span vertical supportrequired
Tees installed 16″ or 24″ on center with 5/8″ drywall oronly on 16″ centers with 1/2″ drywall (Seismic DesignCategories D, E, F)
Tees installed 16″ on center with 5/8″ or 1/2″ drywall(Seismic Design Categories A, B, C)
Hanger Wire Scrap Tee Post Manufactured StrongBack Field Assembled Support QuikStix Uptight Clip
Section Min. Base MetalThickness (in)
Design Thickness(in)
Gross Area (in2)
Effective PropertiesIxx2 (in4) Ma (ft-lb)
ShortSpan 0.0179 0.018 0.090 0.025 42.7
StrongBack 0.0335 0.034 0.092 0.033 45.6
Maximum Load in Lbs./SF (L/240 per ASTM C 645)
Item Item O.C. 3′ Span 4′ Span 5′ Span 6′ Span 7′ Span 8′ Span 10′ Span 12′ Span 14′ Span Number Length Spacing Lbs./SF Lbs./SF Lbs./SF Lbs./SF Lbs./SF Lbs./SF Lbs./SF Lbs./SF Lbs./SF
QSLPM12 12′ 72″ 4.87
QSLPM12 12′ 84″ 2.80
S7708 8′ 16″ 18.38 18.38*
S7708 8′ 24″ 12.25 12.25*
S7710 10′ 16″ 9.97 9.54*
S7710 10′ 24″ 6.64 6.36*
S7712 12′ 16″ 5.51 4.87*
S7712 12′ 24″ 3.67 3.25*
S7714 14′ 16″ 2.80 2.80**
S7714 14′ 16″ 24.70* 9.53**
S7714 14′ 24″ 16.50* 6.36**
QS610 10′ 6″ 3.79
QS810 10′ 8″ 4.41
* Requires mid-span vertical support** Requires two vertical supports at 1/3 points
Note: 5/8″ drywall weighs 2.4 lbs./SF (tees installed 16″ or 24″ on center) 1/2″ drywall weighs 2.0 lbs/SF (tees installed 16″ on center only)
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 11
12
QuikStix™ Soffits DGS
For more information call 1 877 ARMSTRONG
DrywallFramingSystem
Note:
Note:
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
Note:
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
QuikStix Soffits (Patent Pending): Reduces time and labor installing vertical drops
Air Duct
QuikStix
QuikStix QuikStix
QuikStix
QuikStix
QuikStix
QuikStix
LAM-12 Locking Angle Mold
Wall
Wall
LAM-12 Locking Angle Mold LAM-12
Locking Angle Mold
#6 Framing Screw
Deck
90 Degree Drop Soffit
Framing Around Duct Work
Pan Head Screw at Each LAM-12 to Tee Connection
Pan Head Screw at Each LAM-12 to Tee Connection
Membrane Load Values:
Component
Max Load in lbs/SF
Max Load in lbs/SF
Wires 48˝ oc/ Tees 16˝ oc
Wires 36˝ oc/ Tees 16˝ oc
QS610
QS810
2.84 lbs/SF (1 Layer of 5/8˝ Drywall)
5.25 lbs/SF (Up to 2 Layers of 5/8˝ Drywall)
3.30 lbs/SF (1 Layer of 5/8˝ Drywall)
5.58 lbs/SF (Up to 2 Layers of 5/8˝ Drywall)
Note: 5/8˝ drywall weighs 2.4 lbs/SF or less 1/2˝ drywall weighs 2.0 lbs/SF or less Fixtures should be independently supported *For other combinations; consult TechLine at 1-877-Armstrong
Component
Max Load in lbs/SF
Max Loadin lbs/SF
Use Kickers as Needed To Support Lateral Loads
48˝ Max
✓ Knockouts at 6˝ or 8˝ centers reduces cutting time.✓ Alignment holes make screw installation simple and forms perfect 30, 45, 60, 75 and 90 degree angles.✓ Flattened bulb is offset to allow true angles without interference.✓ Bending crimp prevents misalignment.✓ 90 degree angle fits locking angle mold (LAM-12).
30 Angle 45 Angle
60 Angle 75 Angle
Note: Use #6 Framing Screw, screw through clearance hole, then through angle hole
90 Angle
10´
Knockout
Alignment Holes
Flattened Bulb
QuikStix Bending Crimp
Bend UpwardAt Crimp AfterCutting Knockout
0 Angle
Use Snips toMake two Cuts(About 1/4˝Apart) at Knockout Before Bending Trash After
CuttingQuikStix
Flattened Bulb isOffset to allow clearanceWhen Bending
QS610=3˝QS810=4˝
QS610=6˝QS810=8˝
ClearanceHole
Line UpAngle HolesWith ClearanceHole
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 12
13
DrywallFramingSystem
For more information call 1 877 ARMSTRONG
QuikStix™ Wall Liner System
Note:
QSWSB RollLockSupport Bar
Optional space between concrete and Framing System
Electrical cables can run along Support Bar
Framing Tee
QSUTC Clip
QSUTC Clip
Gypsum Board
ElectricalBox
Framing Tee 16˝ o.c.)
Locking Track (Floor)
RigidInsulationin Tees
Rigid Insulationdirectly on concrete wall
RollInsulationin Tees
Fi-Foil Insulation(Adhere on faceof Framing Tee and must beinstalled withair space)
Locking Track joint
10´ Locking Track
Locking Track(Ceiling)
QSWSB RollLockSupport Bar
QuikStix Wall Liner System (Patent Pending): The fast approach to wall framing
✓ QuikStix Locking Track eliminates measuring and marking✓ Framing tees simply click into place, allowing you to keep both feet on the ground✓ RollLock Support Bar and Uptight Clips allow for easy support and anchoring of the system
with chop saw.
Floor LockingTrack
line
Step 4Position Framing Tee into top Locking Track then into bottom Locking Trackuntil locked in place.
10´ Locking Track
Start at left of lock. (Insert top ofFraming Tee first.)
Turn Framing Tee clockwise to lock into top and bottom of track.(Do not twist Tee.)
Start at right of lock. (Slide bottom in last.)
Framing Tee
Optional wood block for baseboard attachment.
Locking Track joint
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 13
14
ShortSpan™ Components
For more information call 1 877 ARMSTRONG
DrywallFramingSystem
ShortSpan Item Details
Note: All components are available with G90 hot dipped galvanized coating. Just add G90 suffix to end of Item #.
Length/Item Profile Simple Span Uniform FireItem # Description Face Dim. Height Load at L/240 (lbs./LF) Resistive Perspective
S7708 8′ ShortSpan Tee 1-1/2″ 1-1/2″ S7710 10′ ShortSpan Tee 1-1/2″ 1-1/2″ S7712 12′ ShortSpan Tee 1-1/2″ 1-1/2″ S7714 14′ ShortSpan Tee 1-1/2″ 1-1/2″
KAM-10 10′ Knurled 1-1/4″ x 1-1/4″ – – – Angle Mold
KAM-12 12′ Knurled 1-1/4″ x 1-1/4″ – – – Angle Mold
LAM-12 12′ Locking 1-1/4″ x 1-1/4″ – – Angle Mold (Locking tabs 8″ o.c.)
SB-12 12′ StrongBack – 2″ – Support (knockouts 8″ o.c.)
PRLAM12 Pre-Rock Locking 1-7/8″ 1-1/4″ – Angle Mold (Locking tabs 8″ o.c.)
LWAWT12 12′ Support Track 144″ x 1-3/8″ x 7/16″
LWAGU08 Gusset for 8″ Mounting 12″ x 2-1/2″LWAGU12 Gusset for 12″ Mounting 17″ x 2-1/2″
QSLPM12 12′ QuikStix Locking 1-1/2″ 1-1/2″ Vertical Supports – Pocket Main @ 4′ o.c. – 21.64 (Locking tabs Vertical Supports 8″ o.c.) @ 3′ o.c. – 40.60
QSUTC QuikStix 1-3/4″ wide 1-1/2″ x – – Uptight Clip 4-1/2″ (Pre-drilled screw holes)
QS610 10′ QuikStix Soffits Tee 1-1/2″ 1-1/2″ 4 ft. Span - 3.79 – (Knockouts 6″ o.c.)
QS810 10′ QuikStix Soffits Tee 1-1/2″ 1-1/2″ 4 ft. Span - 4.41 – (Knockouts 8″ o.c.)
QSWFT09 9′ Framing Tee 1-1/2″ 1-5/8″QSWFT10 10′ Framing Tee 1-1/2″ 1-5/8″ – –QSWFT12 12′ Framing Tee 1-1/2″ 1-5/8″QSWFT14 14′ Framing Tee 1-1/2″ 1-5/8″
QSWLT10 10′ Locking Track 1-1/4″ Tall Face 1-3/4′ (Locking Tabs 1-5/8″ Wide Tall – – 8″ o.c.) Base Back
QSWSB RollLock™ 3/8″ 7/8″ – – 50″ Support Bar
All items:4ft. Span – 24.495ft. Span – 12.656ft. Span – 6.23
Note:
Note:
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
Note:
Max Loadin LBS/SF (L/240)
Max Loadin LBS/SF (L/240)
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 14
For more information call 1 877 ARMSTRONG15
DrywallFramingSystemApplications
24-1/4" Opening
Pan Head Screw Required When Tee Does Not Line Up with Locking Tab
Tee Locked into LAM-12
Adjust Placement of Tee to Accept Opening of
2' x 2' Type F Light Fixture (Cut and Screw)
Tee Positioned 1-1/4" to the Right to Allow Opening for “Type F” Light Fixture
Fixture Supports Provided by Electrical Contractor
LAM-12
2' x 2' Type F Light Fixture
6' High Hat Fixture
Field Assembled Stiff Back
Non-Module Cut and Screw ApplicationMetal to Metal
Drywall Step Vertical
Fixture Installation
16"or 24" O.C. Pan Head Screw Through 2" KAM-12 Angle Molding
4' O.C.
Splice
QuikStix
QuikStix
QuikStix
Vertical QuikStix
Horizontal QuikStix
Gypsum Board
Gypsum Board
Gypsum Board Gypsum Board
Gypsum Board
Screw
DW90C Clip
Deck
12 GaugeHanger WireBrace as requiredby local code
Steel Stud Wall
LAM-12 Locking Angle Mold
LAM-12 Locking Angle Mold
KAM-12 Knurled Angle Mold
45 60 30
75 90
Five Angle Options
#6 Framing Screw
Screw
Screw
y p
3590 drywall framing guide_509b:CS3590 ShortSpan Guide 5/11/09 2:02 PM Page 15
CS-3950 - QuikStix Wall Liner Drywall Framing Systems
For more information call 1 877 ARMSTRONG
© AWI Licensing Company, 2009Printed in United States of AmericaCS-3590-509
CEILING SYSTEMS
1 877 ARMSTRONG (1 877 276 7876)• Name of your Inner Circle Contractor or
Gold Circle Distributor or Sales Representative• Customer Service Representatives
7:30 a.m. to 5:00 p.m. EST, Monday through Friday• TechLine — Technical information —
8 a.m. to 5:30 p.m. EST, Monday through Friday FAX 1-800-572-8324 or email: [email protected]
• Product literature and samples — Express service or regular delivery
• Request a personal copy of the Armstrong CeilingSystems catalog
• Latest product and program news• Real time selection and technical information• Contacts — reps, where to buy, how to install• Submittal pages• Perimeter and CAD renderings
These drawings show typical conditions in which theArmstrong product depicted is installed. They are not asubstitute for an architect’s or engineer’s plan and do notreflect the unique requirements of local building codes,laws, statutes, ordinances, rules and regulations (LegalRequirements) that may be applicable for a particularinstallation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for aparticular installation or their fitness for a particular purpose. The user is advised to consult with a dulylicensed architect or engineer in the particular locale ofthe installation to assure compliance with all LegalRequirements.
Armstrong is not licensed to provide professional architecture or engineering design services.
Engineering data included provided by outside engineering company.
Additional Drywall Systems are available. For more information, visit armstrong.com/drywall or call 877-ARMSTRONG to request literature.
CS-3542 - Synthetic Stucco Grid Systems
CS-3541 -Stucco/Plaster GridSystems
CS-3540 - Drywall Grid Systemsfor Curved Applications
CS-3539 - Drywall Grid Systemsfor Flat Applications
CS-3681 - ShortSpanFraming: What You Needto Know about Load andSeismic Testing
CS-3567 -Drywall GridSystems CD