Notice to ReadersIt is the responsibility of each user to ensure that every battery application is adequately designed safe and compatible with all conditions encountered during use, and in conformance with existing standards and requirements.
This literature contains information concerning cells and batteries manufactured by Matsushita Battery Industrial Co., Ltd. This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs are subject to modification without notice.
United Kingdom/IrelandPanasonic Industrial Europe GmbHWilloughby RoadBracknell BerkshireRG12 8FPEnglandTel: +44 1344-85 32 60Fax: +44 1344-85 33 13
ItalyPanasonic Industrial Europe GmbHVia Lucini 1920125 MilanoTel: +39 02-6788-232Fax: +39 02-6788-207
E-mail and Website for all countries:
battery-solutions@panasonic-industrial.comwww.panasonic-industrial.com/batteries
SpainPanasonic Industrial Europe GmbHAvda. Josep Tarradellas, 20-30, 5°08029 Barcelona - SpainTel: +34 93-494 92 42Fax: +34 93-419 89 31
Germany (all other european countries)Panasonic Industrial Europe GmbHWinsbergring 15 22525 HamburgTel: +49 40-85 386-157Fax: +49 40-85 386-238
FrancePanasonic Industrial Europe GmbH 1 – 3 Avenue François Mitterrand93218 Saint-Denis La PlaineTel: +33 1-55 93 67 10Fax: +33 1-55 93 67 90
For Literature and General Product Information:
For more details, please contact:
Panasonic is a registered trademark of Matsushita Electric Co., Ltd.
2005. Printed in Germany. This catalog has been produced using un-chlorinated paper.
PAN
A/H
B-V
RLA
/200
5
Valve RegulatedLead-Acid Batteries
Technical Handbook
International English
VRLA 2005. Printed in Germany. This catalog has been produced using un-chlorinated paper.
Matsushita Electric Industrial Co. Ltd.,
founded in Osaka 1918, is one of the world’s
largest manufacturers of quality electronic
and electrical equipment. Its subsidiary,
Panasonic Industrial Europe GmbH (PIE)
deals with a wide diversified range of
industrial products for all European coun-
tries. This company was formed in 1998
to strengthen Panasonic’s pan-European
industry operation, and today is active
in such different business fields as
Car Electronics, Components, Consumer
Batteries, OEM/Industrial Batteries etc. to
satisfy its customer’s needs.
Panasonic Industrial EuropeFind out how we can power your business!
PIE Organisation
PIE Branch Hamburg
Home Appliances & Industry Device
Semiconductor
Audio Visual
Industry Battery
Telecom & Computer Device
Automotive & General Industry
Valve Regulated Lead-Acid Batteries 2
Panaso
nic
Batt
eri
es
– sa
fety
, lo
ng-l
ife a
nd p
ow
er!
The Industry Battery Unit (IBU) is respon-
sible for the OEM/Industrial Battery
business in Europe, with sales offices
strategically located throughout the
continent. The head office, located in
Germany (Hamburg), is responsible for
Central Europe (Germany, Benelux, Swiss,
Austria, Scandinavia) and Eastern Europe.
The UK/Ireland (Bracknell), France (Paris),
Italy (Milano) and Spain (Barcelona) are
supported by local offices. In addition, we
are able to offer an extensive distributor
network. Based on both of these sales
channels we are capable of supplying
each customer’s own power solution.
Find out how we can power your business!
Quality CommitmentPanasonic Batter ies – safety, long-l i fe and power!
We are able to offer you a wide range of
individual power solutions for portable
and stationary applications. Our product
range includes high reliability batteries
such as Lithium-Ion, Lithium, Nickel-Metal
Hydrid, Nickel-Cadmium, Valve Regulated
Lead Acid, Alkaline and Zinc Carbon.
Based on this battery range we can power
your business in virtually all applications.
Such as:
➜ Mobi le Phones ➜ Powertools
➜ UPS ➜ Measur ing Devices
➜ Keyless Entry ➜ Personal Care
➜ Vacuum Cleaner
➜ Medical Equipment
➜ E lectronic tol l col lect system
➜ Portable communication devices
➜ Communicat ion infrastructure
Matsushita Batteries Industrial (MBI) star-
ted its production of Panasonic batteries
in 1931. Today MBI is one of the most
diversified global battery manufacturers
with a network of 23 manufacturing com-
panies in 15 countries. More than 16,000
employees are dedicated to the invention
and development of new batteries for a
new world.
When it comes to production our facili-
ties employ leading edge manufacturing
processes meeting the best quality
standards. Our factories are certified to
ISO standards. This means that each fac-
tory has its own quality and environmental
management. The ISO 9000 and ISO
14000 series are the minimum bench-
marks that ensure our excellent product
reliability. In addition our VRLA batteries
are for example approved to German VdS
standard and U.S. UL standard.
Panaso
nic
Batte
ries – sa
fety, lo
ng-life
and p
ow
er!
VdS
3 Valve Regulated Lead-Acid Batteries
LC-Series
Rated Capacity (Ah)
20 hour rate
Nominal Voltage
(V)Model Number
Dimensions (mm)
L W H TH
Massapprox.
(kg)Page VdS N°
LC-R061R3P 6 1.3 97 24 50 55 0.30 5 –
LC-R063R4P 6 3.4 134 34 60 66 0.62 6 –
LC-R064R5P 6 4.5 70 48 102 108 0.72 7 –
LC-R067R2P 6 7.2 151 34 94 100 1.26 8 –
LC-P067R2P 6 7.2 151 34 94 100 1.30 9 –
LC-R0612P 6 12 151 50 94 100 2.00 10 –
LC-P0612P 6 12 151 50 94 100 2.00 11 –
LC-R121R3P 12 1.3 97 47.5 50 55 0.59 12 G196049
LC-R122R2P 12 2.2 177 34 60 66 0.80 13 G188151
LC-P122R2P 12 2.2 177 34 60 66 0.80 14 –
LC-R123R4P 12 3.4 134 67 60 66 1.20 15 G191053
LC-P123R4P 12 3.4 134 67 60 66 1.20 16 –
LC-R124R5P 12 4.5 70 97 102 108 1.45 17 –
LC-R127R2P 12 7.2 151 64.5 94 100 2.47 18 G193046
LC-P127R2P 12 7.2 151 64.5 94 100 2.50 19 –
LC-RA1212P 12 12 151 98 94 100 3.80 20 G100001
LC-PA1212P1 12 12 151 98 94 100 3.80 21 –
LC-CA1212P 12 12 151 98 94 100 3.80 22 –
LC-RA1215P 12 15 151 98 94 100 4.2 23 –
LC-XD1217P / AP 12 17 181 76 167 167 6.5 24 G104101
LC-X1220P / AP 12 20 181 76 167 167 6.6 25 –
LC-X1224P / AP 12 24 165 125 175 179.5 / 175 9.0 26 G198049
LC-X1228P / AP 12 28 165 125 175 179.5 / 175 11.0 27 –
LC-XC1228P 12 28 165 125 175 179.5 10.0 28 –
LC-R1233P 12 33 195.6 130 155 180 12.0 29 –
LC-X1238P / AP 12 38 197 165 175 180 / 175 13.0 30 G100002
LC-XC1238P 12 38 197 165 175 179.5 15.0 31 –
LC-X1242P / AP 12 42 197 165 175 180 / 175 16.0 32 –
LC-X1265P 12 65 350 166 175 175 20.0 33 G199090
LC-PA1275P 12 75 304 171 200 236 26.6 34 –
LC-XB12100P 12 100 407 173 210 236 37.0 35 –
LC-PD12100P 12 100 407 173 210 236 36.6 36 –
UP-Series
Rated Power (W)
(10 minute rate)
Nominal Voltage
(V)Model Number
Dimensions (mm)
L W H TH
Massapprox.
(kg)Page VdS N°
UP-RW0645P1 6 135 151 34 94 100 1.30 37 –
UP-RW1220P1 12 120 140 38.5 94 100 1.35 38 –
UP-RWA1232P1 / P2 12 192 151 51 94 100 2.00 39 –
UP-RW1245P1 12 270 151 64.5 94 100 2.60 40 –
UP-PW1245P1 12 270 151 64.5 94 100 2.60 41 –
Valve Regulated Lead-Acid Batteries 4
5 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
97 1+- 92.9
24 1
4.2 4.2
+-
23.5
50
1+ -
0.3
96.5
4.75
Nominal voltage 6 V
Rated capacity (20 hour rate) 1.3 Ah
Dimensions
Length 97 mm
Width 24 mm
Height 50 mm
Total Height 55 mm
Approx. mass 0.3 kg
Specifications
Dimensions (mm)
7.26.96.6 6.3 6.0 5.7 5.4 5.1 4.8 4.5 4.2 3.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
1.3 A0.26 A 0.13 A 0.065 A
Discharge characteristics (20 °C) (Note)
30
20
15
10
5 4
3
2
1.5
15040
30
20
10
5
330 50 100 300 500 1 3 5 10
(mA) (A)
(Min
ute)
(Hou
r)
Du
ratio
n o
f d
isch
arg
e
Discharge current
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (65 mA)10 hour rate (120 mA)5 hour rate (210 mA)1 hour rate (850 mA)
1.30 Ah1.20 Ah1.05 Ah0.85 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
0.6 A
Internal resistanceFully charged battery
(20 °C)Approx. 50 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Expected trickle life: 6 – 9 years at 20 °C, Approx.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R061R3P
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
Valve Regulated Lead-Acid Batteries 6
Individual Data Sheets
6
133
0.3
134 1.50.5+-
60
1+ -
129.8
33.5
10.1 10.1
34 1+-
+
Nominal voltage 6 V
Rated capacity (20 hour rate) 3.4 Ah
Dimensions
Length 134 mm
Width 34 mm
Height 60 mm
Total Height 66 mm
Approx. mass 0.62 kg
Specifications
Dimensions (mm)
7.26.96.6 6.3 6.0 5.7 5.4 5.1 4.8 4.5 4.2 3.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
1.7 A 0.85 A0.34 A 0.17 A
3.4 A
Discharge characteristics (20 °C) (Note)
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
330 50 100 300 500 1 3 5 10
Discharge current(mA) (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (170 mA)10 hour rate (300 mA)5 hour rate (540 mA)
1 hour rate (2100 mA)
3.40 Ah3.00 Ah2.70 Ah2.10 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
1.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 30 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R063R4P
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
7 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
48 1+-
47.4
7 7+-70 1
69.2 0
.310
2 1
.5+ -
0.5 6
Nominal voltage 6 V
Rated capacity (20 hour rate) 4.5 Ah
Dimensions
Length 70 mm
Width 48 mm
Height 102 mm
Total Height 108 mm
Approx. mass 0.72 kg
Specifications
Dimensions (mm)
6.96.66.36.05.75.45.14.84.54.23.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Ter
min
al v
olta
ge (
V)
13.50 A
4.50 A1.125 A 0.225 A
Discharge characteristics (20 °C) (Note)
100 200 300 500 1 2 3 5 7 10 20
(mA) (A)
Discharge current
30
20
15
10
5 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (225 mA)10 hour rate (400 mA)5 hour rate (720 mA)
1 hour rate (2800 mA)
4.5 Ah4.0 Ah3.6 Ah2.8 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
2.2 A
Internal resistanceFully charged battery
(20 °C)Approx. 20 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Expected trickle life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R064R5P
Battery case resin: Standard (UL94HB)
Terminal type: Faston 187
Valve Regulated Lead-Acid Batteries 8
Individual Data Sheets
0.3
94
+ -1
.5 0.5
130.3 6
150.2
151 +-1.50.5
33.2
9
34 +-1.00.5
Nominal voltage 6 V
Rated capacity (20 hour rate) 7.2 Ah
Dimensions
Length 151 mm
Width 34 mm
Height 94 mm
Total Height 100 mm
Approx. mass 1.26 kg
Specifications
Dimensions (mm)
7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Discharge time
Term
ina
l vo
ltag
e (
V)
23.04 A
11.52 A5.76 A
2.88 A 1.44 A0.72 A 0.36 A
Discharge characteristics (20 °C) (Note)
100 300 500 1 3 5 10 30 50
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (360 mA)10 hour rate (680 mA)5 hour rate (1260 mA)1 hour rate (4900 mA)
7.2 Ah6.8 Ah6.3 Ah4.9 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
3.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 20 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R067R2P
Terminal type: Faston 187 or Faston 250 with hole
Battery case resin: Standard (UL94HB)
9 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
0.3
94
+ -1
.5 0.5
130.3
6
150.2
151 +-1.50.5
33.2
9
34 +-1.50.5
Nominal voltage 6 V
Rated capacity (20 hour rate) 7.2 Ah
Dimensions
Length 151 mm
Width 34 mm
Height 94 mm
Total Height 100 mm
Approx. mass 1.3 kg
Specifications
Dimensions (mm)
7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
23.04 A11.52 A
1.44 A 0.72 A 0.36 A
5.76 A2.88 A
Discharge characteristics (20 °C) (Note)
100 300 500 1 3 5 10 30 50
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C0˚C
15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (360 mA)10 hour rate (680 mA)5 hour rate (1260 mA)1 hour rate (4900 mA)
7.2 Ah6.8 Ah6.3 Ah4.9 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
3.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 20 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.(Note) For cycle use of the battery, please contact us in advance.
LC-P067R2P
Battery case resin: Flame-retardant (UL94V-0)
The total height of #250 terminal is 101.5 mm.
Terminal type: Faston 187
Valve Regulated Lead-Acid Batteries 10
Individual Data Sheets
0.3
94
+ -1
.5 0.5
130.3
6
150.2
151 +-1.50.5
49.2
16
50 +-1.50.5
Nominal voltage 6 V
Rated capacity (20 hour rate) 12 Ah
Dimensions
Length 151 mm
Width 50 mm
Height 94 mm
Total Height 100 mm
Approx. mass 2 kg
Specifications
Dimensions (mm)
7.26.96.66.36.05.75.45.14.84.54.23.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
3.0 A 1.2 A 0.6 A
24.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
12.0 A6.0 A
Discharge characteristics (20 °C) (Note)
300 500 1 3 5 10 30 50 100
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(mA) (A)
Discharge current
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (600 mA)10 hour rate (1130 mA)
5 hour rate (2080 mA)1 hour rate (8100 mA)
12.0 Ah11.3 Ah10.4 Ah8.1 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
5.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 15 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R0612P
Terminal type: Faston 187 or Faston 250 with hole
Battery case resin: Standard (UL94HB)
The total height of #250 terminal is 101.5 mm.
11 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
0.3
94
+ -1
.5 0.5
130.3
6
150.2
151 +-1.50.5
49.2
16
50 +-1.50.5
Nominal voltage 6 V
Rated capacity (20 hour rate) 12 Ah
Dimensions
Length 151 mm
Width 50 mm
Height 94 mm
Total Height 100 mm
Approx. mass 2 kg
Specifications
Dimensions (mm)
7.26.96.66.36.05.75.45.14.84.54.23.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
3.0 A 1.2 A 0.6 A
24.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
12.0 A6.0 A
Discharge characteristics (20 °C) (Note)
300 500 1 3 5 10 30 50 100
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(mA) (A)
Discharge current
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (600 mA)10 hour rate (1130 mA)
5 hour rate (2080 mA)1 hour rate (8100 mA)
12.0 Ah11.3 Ah10.4 Ah8.1 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
5.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 15 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.(Note) For cycle use of the battery, please contact us in advance.
LC-P0612P
Terminal type: Faston 187 or Faston 250 with hole
Battery case resin: Flame-retardant (UL94V-0)
The total height of #250 terminal is 101.5 mm.
Valve Regulated Lead-Acid Batteries 12
97 1 +-+- 47.5 1
30.84.75
+ -
470.3
50
1
96.5
Nominal voltage 12 V
Rated capacity (20 hour rate) 1.3 Ah
Dimensions
Length 97 mm
Width 47.5 mm
Height 50 mm
Total Height 55 mm
Approx. mass 0.59 kg
Specifications
Dimensions (mm)
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
1.3 A0.26 A 0.13 A 0.065 A
Discharge characteristics (20 °C) (Note)
30
20
15
10
5
4
3
2
1.5
15040
30
20
10
5
330 50 100 300 500 1 3 5 10
Discharge current
(mA) (A)
(Min
ute)
(Hou
r)
Du
ratio
n o
f d
isch
arg
e
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (65 mA)10 hour rate (120 mA)5 hour rate (210 mA)1 hour rate (850 mA)
1.30 Ah1.20 Ah1.05 Ah0.85 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
0.6 A
Internal resistanceFully charged battery
(20 °C)Approx. 90 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Expected trickle life: 6 – 9 years at 20 °C, Approx.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R121R3P
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
VdS
13 Valve Regulated Lead-Acid Batteries
Individual Data SheetsIndividual Data Sheets
177 1.50.5+-
173.3
17633.5
0.3
60
1+ -
34 1+-
6 10.1
2.8
Nominal voltage 12 V
Rated capacity (20 hour rate) 2.2 Ah
Dimensions
Length 177 mm
Width 34 mm
Height 60 mm
Total Height 66 mm
Approx. mass 0.8 kg
Specifications
Dimensions (mm)
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
2.2 A 1.1 A0.55 A 0.22 A
0.11 A
Discharge characteristics (20 °C) (Note)
30 50 100 300 500 1 3 5 10
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (110 mA)10 hour rate (200 mA)5 hour rate (360 mA)
1 hour rate (1300 mA)
2.2 Ah2.0 Ah1.8 Ah1.3 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
0.95 A
Internal resistanceFully charged battery
(20 °C)Approx. 70 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R122R2P
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
VdS
Valve Regulated Lead-Acid Batteries 14
Individual Data Sheets
Nominal voltage 12 V
Rated capacity (20 hour rate) 2.2 Ah
Dimensions
Length 177 mm
Width 34 mm
Height 60 mm
Total Height 66 mm
Approx. mass 0.8 kg
Specifications
Dimensions (mm)
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
2.2 A 1.1 A0.55 A 0.22 A
0.11 A
Discharge characteristics (20 °C) (Note)
30 50 100 300 500 1 3 5 10
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (110 mA)10 hour rate (200 mA)5 hour rate (360 mA)
1 hour rate (1300 mA)
2.2 Ah2.0 Ah1.8 Ah1.3 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
0.95 A
Internal resistanceFully charged battery
(20 °C)Approx. 70 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Expected trickle life: Approx. 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-P122R2P
177 1.50.5+-
173.3
17633.5
0.3
60
1+ -
34 1+-
6 10.1
2.8
Terminal type: Faston 187
Battery case resin: Flame-retardant (UL94V-0)
15 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
Nominal voltage 12 V
Rated capacity (20 hour rate) 3.4 Ah
Dimensions
Length 134 mm
Width 67 mm
Height 60 mm
Total Height 66 mm
Approx. mass 1.2 kg
Specifications
Dimensions (mm)
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
1.7 A 0.85 A0.34 A 0.17 A
3.4 A
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
Discharge characteristics (20 °C) (Note)
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
330 50 100 300 500 1 3 5 10
Discharge current
(mA) (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (170 mA)10 hour rate (300 mA)5 hour rate (540 mA)
1 hour rate (2100 mA)
3.4 Ah3.0 Ah2.7 Ah2.1 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
1.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 60 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R123R4P
6 53.2
66.5133
0.3
134 +-1.50.5+- 67 1
60
1+ -
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
VdS
Valve Regulated Lead-Acid Batteries 16
Nominal voltage 12 V
Rated capacity (20 hour rate) 3.4 Ah
Dimensions
Length 134 mm
Width 67 mm
Height 60 mm
Total Height 66 mm
Approx. mass 1.2 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (170 mA)10 hour rate (300 mA)5 hour rate (540 mA)
1 hour rate (2100 mA)
3.4 Ah3.0 Ah2.7 Ah2.1 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
1.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 60 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Expected trickle life: Approx. 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-P123R4P
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
1.7 A 0.85 A0.34 A 0.17 A
3.4 A
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
6 53.2
66.5133
0.3
134 +-1.50.5+- 67 1
60
1+ -
Battery case resin: Flame-retardant (UL94V-0)
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
330 50 100 300 500 1 3 5 10
Discharge current
(mA) (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Terminal type: Faston 187
17 Valve Regulated Lead-Acid Batteries
Individual Data Sheets
Nominal voltage 12 V
Rated capacity (20 hour rate) 4.5 Ah
Dimensions
Length 70 mm
Width 97 mm
Height 102 mm
Total Height 108 mm
Approx. mass 1.45 kg
Specifications
Dimensions (mm)
14.413.813.212.612.011.410.810.29.69.08.47.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
Duration of discharge
Ter
min
al v
olta
ge (
V)
13.50 A
4.50 A1.13 A 0.225 A
Discharge characteristics (20 °C) (Note)
100 200 300 500 1 2 3 5 7 10 20
(mA) (A)
Discharge current
30
20
15
10
5 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (210 mA)10 hour rate (390 mA)5 hour rate (700 mA)
1 hour rate (2800 mA)
4.5 Ah3.9 Ah3.5 Ah2.8 Ah
1.5 hour rate dischargeCut-off voltage 5.25 V
2.2 A
Internal resistanceFully charged battery
(20 °C)Approx. 40 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R124R5P
3.82 +-0.080.04
(97 +-21)
(49) (17)1.93 0.67
(70 +-21 )
2.76 +-0.080.04
(70 +-21 )
2.76 +-0.080.04
(102
xxxx
)
4.02
xx
xx(6
)0.
24
(0.3
)0.
01
(69.2)2.72
Terminal type: Faston 187
Battery case resin: Standard (UL94HB)
18
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 7.2 Ah
Dimensions
Length 151 mm
Width 64.5 mm
Height 94 mm
Total Height 100 mm
Approx. mass 2.5 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (360 mA)10 hour rate (680 mA)5 hour rate (1260 mA)1 hour rate (4900 mA)
7.2 Ah6.8 Ah6.3 Ah4.9 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
3.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 40 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-R127R2P
7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Discharge time
Term
ina
l vo
ltag
e (
V)
23.04 A
11.52 A5.76 A
2.88 A 1.44 A0.72 A 0.36 A
63.7
151 +-1.50.5
150.2 0.3
94
+ -1.5 0.5
665.15
64.5 +-1.50.5 48
Battery case resin: Standard (UL94HB)
100 300 500 1 3 5 10 30 50
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C0˚C
-15˚C
The total height of #250 terminal is 101.5 mm.
Terminal type: Faston 187 or Faston 250 with hole
VdS
Nominal voltage 12 V
Rated capacity (20 hour rate) 7.2 Ah
Dimensions
Length 151 mm
Width 64.5 mm
Height 94 mm
Total Height 100 mm
Approx. mass 2.5 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (360 mA)10 hour rate (680 mA)5 hour rate (1260 mA)1 hour rate (4900 mA)
7.2 Ah6.8 Ah6.3 Ah4.9 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
3.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 40 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.(Note) For cycle use of the battery, please contact us in advance.
LC-P127R2P
15.0 14.0 13.012.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Discharge time
Term
ina
l vo
ltag
e (
V)
23.04 A
11.52 A5.76 A
2.88 A 1.44 A0.72 A 0.36 A
63.7
151 +-1.50.5
150.2 0.3
94
+ -1.5 0.5
665.15
64.5 +-1.50.5 48
Battery case resin: Flame-retardant (UL94V-0)
100 300 500 1 3 5 10 30 50
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C0˚C
-15˚C
The total height of #250 terminal is 101.5 mm.
Terminal type: Faston 187 or Faston 250 with hole
19
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
20
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 12 Ah
Dimensions
Length 151 mm
Width 98 mm
Height 94 mm
Total Height 100 mm
Approx. mass 3.8 kg
Specifications
Dimensions (mm)
14.413.813.212.612.011.410.810.2
9.69.08.47.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
6.0 A 3.0 A1.2 A 0.6 A
24.0 A12.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
Discharge characteristics (20 °C) (Note)
300 500 1 3 5 10 30 50 100
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(mA) (A)
Discharge current
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (600 mA)10 hour rate (1130 mA)
5 hour rate (2080 mA)1 hour rate (8100 mA)
12.0 Ah11.3 Ah10.4 Ah8.1 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
5.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 30 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge (20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-RA1212P
151 +-1.50.5
0.3
6
13.5±0.75
98 +-1.50.5
10 1.0+
94
+ -1
.5 0.5
Battery case resin: Standard (UL94HB)
Terminal type: Faston 187 or Faston 250 with hole
VdS
Nominal voltage 12 V
Rated capacity (20 hour rate) 12 Ah
Dimensions
Length 151 mm
Width 98 mm
Height 94 mm
Total Height 100 mm
Approx. mass 3.8 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (600 mA)10 hour rate (1130 mA)
5 hour rate (2080 mA)1 hour rate (8100 mA)
12.0 Ah11.3 Ah10.4 Ah8.1 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
5.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 30 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Expected trickle life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-PA1212P1
14.413.813.212.612.011.410.810.2
9.69.08.4
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
6.0 A 3.0 A1.2 A 0.6 A
24.0 A
12.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
150.2
151 +-1.50.5
0.3
6 13.5±0.75
98 +-1.50.5
10 1.0 +-
94
+ -1
.5 0.5
Battery case resin: Flame-retardant (UL94V-0)
300 500 1 3 5 10 30 50 100
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
21
Individual Data Sheets
Terminal type: Faston 250 with hole
Valve Regulated Lead-Acid Batteries
22
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 12 Ah
Dimensions
Length 151 mm
Width 98 mm
Height 94 mm
Total Height 100 mm
Approx. mass 3.8 kg
Specifications
Dimensions (mm)
13.813.212.612.011.410.810.2
9.69.08.47.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
3.0 A 1.2 A0.6 A
24.0 A12.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
6.0 A
Discharge characteristics (20 °C) (Note)
300 500 1 3 5 10 30 50 100
(mA) (A)
Discharge current
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For main power supplies.Cycle long life type. Approx. 1200 cycles acc. IEC 896 T2).
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-CA1212P
Capacity (note)
(20 °C)
20 hour rate (600 mA)10 hour rate (1130 mA)
5 hour rate (2080 mA)1 hour rate (8100 mA)
12.0 Ah11.3 Ah10.4 Ah8.1 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
5.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 30 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
150.2
151 +-1.50.5
0.3
6 13.5±0.75
98 +-1.50.5
10 1.0 +-
94
+ -1
.5 0.5
Terminal type: Faston 187 or Faston 250 with hole
Battery case resin: Standard (UL94HB)
Nominal voltage 12 V
Rated capacity (20 hour rate) 15 Ah
Dimensions
Length 151 mm
Width 98 mm
Height 94 mm
Total Height 100 mm
Approx. mass 4.2 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (750 mA)10 hour rate (1.40 A)5 hour rate (2.58 A)
1 hour rate (10.00 A)
15.0 Ah14.0 Ah12.9 Ah10.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
7.1 A
Internal resistanceFully charged battery
(20 °C)Approx. 30 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Expected trickle life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-RA1215P
14.413.813.212.612.011.410.810.2
9.69.08.47.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
3.75 A 1.4 A0.75 A
30.0 A15.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
7.5 A
Battery case resin: Standard (UL94HB)
300 500 1 3 5 10 30 50 100
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(mA) (A)
Discharge current
40˚C
20˚C
0˚C
-15˚C
150.2
151 +-1.50.5
0.3
6 13.5±0.75
98 +-1.50.5
10 1.0 +-
94
+ -1
.5 0.5
23
Individual Data Sheets
Terminal type: Faston 187 or Faston 250 with hole
Valve Regulated Lead-Acid Batteries
24
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 17 Ah
Dimensions
Length 181 mm
Width 76 mm
Height 167 mm
Total Height 167 mm
Approx. mass 6.5 kg
Specifications
Dimensions (mm)
14.413.813.212.612.011.410.810.2
9.69.08.47.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
4.25 A 1.7 A0.85 A
51.0 A34.0 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
17.0 A
Discharge characteristics (20 °C) (Note)
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
3 300 500 1 3 5 10 30 50 100
Discharge current(mA) (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Expected trickle life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-XD1217P/AP
76 2
22
11
74.5
5.5
12
.51
53
.5
16
7
2
181 2
5 112.5 5
179.5
+ -
+-
+-
1
Battery case resin: Standard (UL94HB)
Capacity (note)
(20 °C)
20 hour rate (850 mA)10 hour rate (1.5 A)5 hour rate (2.6 A)
1 hour rate (10.0 A)
17.0 Ah15.0 Ah13.0 Ah10.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
7.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 12 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
VdS
Terminal type: LC-XD1217P: M5 bolt and nutLC-XD1217AP: M5 threaded post
Nominal voltage 12 V
Rated capacity (20 hour rate) 20 Ah
Dimensions
Length 181 mm
Width 76 mm
Height 167 mm
Total Height 167 mm
Approx. mass 6.6 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (1.2 A)10 hour rate (2.2 A)
5 hour rate (3.8 A)1 hour rate (12.0 A)
20.0 Ah18.0 Ah16.0 Ah12.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
9.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 11 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.(Note) For cycle use of the battery, please contact us in advance.
LC-X1220P/AP
14.413.813.212.612.011.410.810.2
9.69.08.47.87.2
Duration of Discharge
Term
ina
l vo
ltag
e (
V)
(Minute) (Hour)
60.0 A40.0 A
20.0 A5.0 A 2.0 A 1.0 A
0 2 4 68101 20 40 60 2 4 6 810 20 40
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
3 300 500 1 3 5 10 30 50 100
Discharge current(mA) (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
0˚C
-15˚C
20˚C
76 2
22
11
74.5
5.5
12
.51
53
.5
16
7
2
181 2
5 112.5 5
179.5
+ -
+-
+-
1
Battery case resin: Standard (UL94HB)
Terminal type: LC-X1220P: M5 bolt and nutLC-X1220AP: M5 threaded post
25
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
26
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 24 Ah
Dimensions
Length 165 mm
Width 125 mm
Height 175 mm
Total HeightLC-X1224AP: 175 mmLC-X1224P: 179.5 mm
Approx. mass 9.0 kg
Specifications
Dimensions (mm)
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
72.0 A48.0 A
24.0 A6.0 A 2.4 A
1.2 A
Discharge characteristics (20 °C) (Note)
30
20
15
10
5
4
3
2
1.5
1 50 40
30
20
10
5
3 0.3 0.5 1 3 5 10 30 50 100
Discharge current (A)
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge 40˚C
0˚C
-15˚C
20˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-X1224P/AP
163.4
9.8
124
175
2
+ -
8.3
2.2
12
125 2
12
165 2
134
90
45.5
+-+-
Battery case resin: Standard (UL94HB)
Capacity (note)
(20 °C)
20 hour rate (1.2 A)10 hour rate (2.2 A)
5 hour rate (3.8 A)1 hour rate (14.0 A)
24.0 Ah22.0 Ah19.0 Ah14.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
9.8 A
Internal resistanceFully charged battery
(20 °C)Approx. 11 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Terminal type: LC-X1224AP: M5 threaded postLC-X1224P: M5 bolt and nut
VdS
Nominal voltage 12 V
Rated capacity (20 hour rate) 28 Ah
Dimensions
Length 165 mm
Width 125 mm
Height 175 mm
Total HeightLC-X1228AP: 175 mmLC-X1228P: 179.5 mm
Approx. mass 11.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (1.40 A)10 hour rate (2.65 A)5 hour rate (5.00 A)
1 hour rate (21.00 A)
28.0 Ah26.5 Ah25.0 Ah21.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
14.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 8 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-X1228P/AP
13.513.012.512.011.511.010.510.09.5
9.08.5
8.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
56.0 A
7.0 A 1.4 A 14.0 A2.8 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
28.0 A
1 5 10 50 100 500
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
163.4
9.8
124
175
2
+ -
8.3
2.2
12
125 2
12
165 2
134
90
45.5
+-+-
Battery case resin: Standard (UL94HB)
Terminal type: LC-X1228AP: M5 threaded post LC-X1228P: M5 bolt and nut
27
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
28
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 28 Ah
Dimensions
Length 165 mm
Width 125 mm
Height 175 mm
Total Height 179.5 mm
Approx. mass 11.0 kg
Specifications
Dimensions (mm)
13.513.012.512.011.511.010.510.09.5
9.08.5
8.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
56.0 A
7.0 A 1.4 A 14.0 A2.8 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
28.0 A
Discharge characteristics (20 °C) (Note)
1 5 10 50 100 500
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For main power supplies.Cycle long life type. Approx. 1200 cycles (acc. IEC 896 T2).
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-XC1228P
163.4
9.8
124
175
2
+ -
8.3
2.2
12
125 2
12
165 2
134
90
45.5
+-+-
Battery case resin: Standard (UL94HB)
Capacity (note)
(20 °C)
20 hour rate (1.40 A)10 hour rate (2.65 A)5 hour rate (5.00 A)
1 hour rate (21.00 A)
28.0 Ah26.5 Ah25.0 Ah21.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
14.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 10 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Terminal type: M5 bolt and nut
Nominal voltage 12 V
Rated capacity (20 hour rate) 33 Ah
Dimensions
Length 195.6 mm
Width 130 mm
Height 155 mm
Total Height 180 mm
Approx. mass 12.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (1.65 A)10 hour rate (3.00 A)5 hour rate (5.40 A)
1 hour rate (20.00 A)
33.0 Ah30.0 Ah27.0 Ah20.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
13.4 A
Internal resistanceFully charged battery
(20 °C)Approx. 7 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main and standby power supplies.Expected trickle life: 6 – 9 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.(Note) For cycle use of the battery, please consult us in advance.
LC-R1233P
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
105.6 A
52.8 A
26.4 A13.2 A 6.6 A
3.3 A 1.65 A
30
20
15
10
7
5 4
3
2
1.5
1 50 40
30
2015
10
7
5
31 2 3 4 5 7 10 20 30 40 50 70 100 200 300
Discharge current(A)
(Min
ute)
(Hou
r)
Du
ratio
n o
f d
isch
arg
e
20˚C
0˚C
-15˚C
+ -
130 2
50
26.5
4.5
6
180
155
2
9
7.5
195.6 2
159
16
194.6
+-+-
125
Battery case resin: Standard (UL94HB)Flame-retardant (UL94V-0)
Terminal type: M6 bolt and nut
29
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
30
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 38 Ah
Dimensions
Length 197 mm
Width 165 mm
Height 175 mm
Total HeightLC-X1238AP: 175 mmLC-X1238P: 180 mm
Approx. mass 13.0 kg
Specifications
Dimensions (mm)
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
22.0 A6.3 A
38.0 A
3.5 A 1.9 A
Discharge characteristics (20 °C) (Note)
1 3 5 10 30 50 100
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-X1238P/AP
Capacity (note)
(20 °C)
20 hour rate (1.9 A)10 hour rate (3.5 A)
5 hour rate (6.3 A)1 hour rate (22.5 A)
38.0 Ah35.0 Ah31.5 Ah22.5 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
15.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 8 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
195.2
9.8
164
175
2+ -
8.3
2.2
11.5
165 2
27.5
+-
61
197 2155
111
+-
Battery case resin: Standard (UL94HB)
Terminal type: LC-X1238AP: M5 threaded postLC-X1238P: M6 bolt and nut
VdS
Nominal voltage 12 V
Rated capacity (20 hour rate) 38 Ah
Dimensions
Length 197 mm
Width 165 mm
Height 175 mm
Total Height 179.5 mm
Approx. mass 15.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)
20 hour rate (1.9 A)10 hour rate (3.5 A)
5 hour rate (6.3 A)1 hour rate (22.5 A)
38.0 Ah35.0 Ah31.5 Ah22.5 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
15.5 A
Internal resistanceFully charged battery
(20 °C)Approx. 9 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For main power supplies.Cycle long life type. Approx. 1200 cycles (acc. IEC 896 T2).
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-XC1238P
14.413.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
22.0 A6.3 A
38.0 A
3.5 A 1.9 A
195.2
9.8
164
175
2+ -
8.3
2.2
11.5
165 2
27.5
+-
61
197 2155
111
+-
Battery case resin: Standard (UL94HB)
Terminal type: M6 bolt and nut
1 3 5 10 30 50 100
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
20˚C
0˚C
-15˚C
31
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
32
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 42 Ah
Dimensions
Length 197 mm
Width 165 mm
Height 175 mm
Total HeightLC-X1242AP: 175 mmLC-X1242P: 180 mm
Approx. mass 16.0 kg
Specifications
Dimensions (mm)
13.513.012.512.011.511.010.510.09.5
9.08.5
8.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
84.0 A
42.0 A10.5 A 2.1 A 21.0 A
4.2 A
(Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
Discharge characteristics (20 °C) (Note)
1 5 10 50 100 500
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-X1242P/AP
Capacity (note)
(20 °C)
20 hour rate (2.1 A)10 hour rate (4.0 A)
5 hour rate (7.4 A)1 hour rate (26.0 A)
42.0 Ah40.0 Ah37.0 Ah26.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
20.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 8 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
195.2
9.8
164
175
2+ -
8.3
2.2
11.5
165 2
27.5
+-
61
197 2155
111
+-
Battery case resin: Standard (UL94HB)
Terminal type: LC-X1242AP: M5 threaded postLC-X1242P: M6 bolt and nut
Nominal voltage 12 V
Rated capacity (20 hour rate) 65 Ah
Dimensions
Length 350 mm
Width 166 mm
Height 175 mm
Total Height 175 mm
Approx. mass 20.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (3.25 A)10 hour rate (5.90 A)5 hour rate (10.60 A)1 hour rate (40.00 A)
65.0 Ah59.0 Ah53.0 Ah40.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
26.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 7 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Trickle Design life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-X1265P
13.513.012.512.011.511.010.510.0 9.5
9.0 8.5
8.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
3.25 A16.25 A
350 2
265
137.8 7
166 2
63.5
48.2
79.818
343.6 164.5
175
2
155
18
+-
+ -
+-
Battery case resin: Standard (UL94HB)
Terminal type: M6 bolt and nut
1 5 10 50 100 500
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(A)
Discharge current (A)
(Min
ute)
(Hou
r)
Du
ratio
n o
f d
isch
arg
e
20˚C
40˚C
0˚C
-15˚C
VdS
33
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
34
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 75 Ah
Dimensions
Length 304 mm
Width 171 mm
Height 200 mm
Total Height 236 mm
Approx. mass 26.6 kg
Specifications
Dimensions (mm)
13.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
75.0 A42.0 A
11.2 A 6.7 A 3.8 A
Discharge characteristics (20 °C) (Note)
3 3 10 30 50 100 300 500 1000
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(A)
Discharge current
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Expected trickle life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-PA1275P
304 2+-171 2+-164.4
(170)
209.5ø38.5
2220
0 2+ -
236
MA
X
(303)
20
10
87.4
Battery case resin: Flame-retardant (UL94V-0)
Capacity (note)
(20 °C)
20 hour rate (3.8 A)10 hour rate (6.7 A)5 hour rate (11.2 A)1 hour rate (42.0 A)
75.0 Ah67.0 Ah56.0 Ah42.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
30.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 5.0 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Terminal type: M6 bolt and nut
Nominal voltage 12 V
Rated capacity (20 hour rate) 100 Ah
Dimensions
Length 407 mm
Width 173 mm
Height 210 mm
Total Height 236 mm
Approx. mass 37.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)(20 °C)
20 hour rate (5.0 A)10 hour rate (9.8 A)5 hour rate (18.0 A)1 hour rate (75.0 A)
100.0 Ah98.0 Ah90.0 Ah75.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
50.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 4.5 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Expected trickle life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-XB12100P
13.0 12.0 11.0 10.0 9.0 8.0
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Discharge time
Term
ina
l vo
ltag
e (
V)
200 A100 A
50 A 25 A10 A 5 A
172
110
173 2
407 2
275 2
8
24 26
406
2
10
2+ -
+-+-
+-
Battery case resin: Flame-retardant (UL94V-0)
1 5 10 50 100 500
Discharge current (A)
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
40˚C
0˚C
-15˚C
20˚C
(A)
Terminal type: M8 bolt and nut
35
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
36
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Nominal voltage 12 V
Rated capacity (20 hour rate) 100 Ah
Dimensions
Length 407 mm
Width 173 mm
Height 210 mm
Total Height 236 mm
Approx. mass 36.6 kg
Specifications
Dimensions (mm)
13.8 13.2 12.6 12.0 11.4 10.8 10.2 9.6 9.0 8.4 7.8
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40 (Minute) (Hour)
Duration of discharge
Term
ina
l vo
ltag
e (
V)
100.0 A56.0 A
15.0 A 9.0 A 5.0 A
Discharge characteristics (20 °C) (Note)
3 3 10 30 50 100 300 500 1000
30
20
15
10
5 4 3 2
1.5
1 50 40
30
20
10
5
3
(Min
ute)
(Hou
r)D
ura
tion
of
dis
cha
rge
(A)
Discharge current
20˚C
0˚C
-15˚C
Duration of discharge vs. Discharge current (Note)
Characteristics
For standby power supplies.Expected trickle life: 10 – 12 years at 20 °C.
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values.
LC-PD12100P
172
110
173 2
407 2
275 2
8
24 26
406
2
10
2+ -
+-+-
+-
Battery case resin: Flame-retardant (UL94V-0)
Capacity (note)
(20 °C)
20 hour rate (5.0 A)10 hour rate (9.0 A)5 hour rate (15.0 A)1 hour rate (56.0 A)
100.0 Ah90.0 Ah75.0 Ah56.0 Ah
1.5 hour rate dischargeCut-off voltage 10.5 V
40.0 A
Internal resistanceFully charged battery
(20 °C)Approx. 4.5 mΩ
Temperature dependency of capacity (20 hour rate)
40 °C20 °C
0 °C-15 °C
102 %100 %
85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Terminal type: M8 bolt and nut
Nominal voltage 6 V
Nominal capacity (10 minute rate) 45 W/2 V
Dimensions
Length 151 mm
Width 34 mm
Height 94 mm
Total Height 100 mm
Approx. mass 1.3 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)(9.6 V cutoff)
30 minute rate15 minute rate10 minute rate5 minute rate
56 W97 W
134 W205 W
Internal resistanceFully charged battery (20 °C)
Approx. 11 mΩ
Temperature dependency of capacity (10 hour rate)
40 °C20 °C0 °C
-15 °C
102 %100 %85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
For standby power supplies.Expected trickle life: 6 – 9 years at 20 °C.UP-RW0645P1
6.96.66.36.05.75.45.14.84.54.23.9
0 1 2 4 6 8 10 20 40 60 100 200
27.0 A
9.0 A2.25 A
Duration of discharge (minute)
7.2
80
Te
rmin
al
volt
ag
e(V
)
0.3
94
+ -1
.5 0.5
130.3 6
150.2
151 +-1.50.5
33.2
9
34 +-1.00.5
Battery case resin: Standard (UL94HB)
1,500
300
100
30
10
3
1,0001,200
5
50
500
Dur
atio
n of
dis
char
ge (
Min
ute)
Discharge current (A)0.2 0.5 1 3 5 10 30 50 100
40˚C
20˚C
0˚C
-15˚CCutoff
Discharge Runtime at 20 °C
3 min. 5 min. 7 min. 10 min. 15 min. 20 min. 30 min.
9.6 V 265 205 165 134 97 79 56
10.2 V 245 195 157 129 96 78 55
10.8 V 217 165 137 117 90 73 54
Watt table
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values. This battery is designed for high-rate-discharge and we do not specify 20 hour rate discharge capacity. For cycle use of the battery, please contact Panasonic in advance.
37
Individual Data Sheets
Terminal Type: Faston 250 with hole
Valve Regulated Lead-Acid Batteries
38
Individual Data Sheets
Valve Regulated Lead-Acid Batteries
Dimensions (mm)
14.413.813.212.612.011.4
10.810.29.69.08.47.8
0 1 2 4 10 20 40 60 100 200
12.0 A
4.0 A
1.0 A
Term
ina
l vo
ltag
e (
V)
(Minute)Duration of discharge
Discharge characteristics (20 °C) (Note)
0.2 0.5 1 2 5 10 20 50 100
20°C
-15°C
40°C
3
10
50
100
300
500
1000
1500 1200
30
5
Du
ratio
n o
f d
isch
arg
e(M
inu
te)
(A)Discharge current
0°C
Duration of discharge vs. Discharge current (Note)
For standby power supplies.Trickle Design life: 6 – 9 years at 20 °C.UP-RW1220P1
37.7
140 +-1.50.5
139.2
0.3
94
+ -1.5 0.5
( 5
)
38.5 +-1.50.525 59.6
Battery case resin: Standard (UL94HB)
Nominal voltage 12 V
Nominal capacity (10 minute rate) 20 W/2 V
Dimensions
Length 140.0 mm
Width 38.5 mm
Height 94.0 mm
Total Height max. 100 mm
Approx. mass 1.35 kg
Specifications
Capacity (note) (20 °C)
(9.6 V cutoff)
30 minute rate15 minute rate10 minute rate5 minute rate
155 W86 W
114 W171 W
Internal resistanceFully charged battery (20 °C)
Approx. 44 mΩ
Temperature dependency of capacity (10 hour rate)
40 °C20 °C0 °C
-15 °C
102 %100 %85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 months
91 %
83 %
66 %
Characteristics
CutoffDischarge Runtime at 20 °C (unit: watt)
3 min. 5 min. 7 min. 10 min. 15 min. 20 min. 30 min.
9.6 V 225 171 142 114 86 72 55
10.2 V 206 158 128 107 82 70 50
10.8 V 168 130 109 96 77 64 45
Watt table
(Note) The above characteristics data are average values obtained within three charge/discharge cycles, not the minimum values. (Note) This battery is designed for high-rate discharge, therefore we do not specify 20-hour-rate discharge capacity.(Note) When specific conditions are satisfied, this battery can be used for main power supplies. Please consult Panasonic.
Terminal Type: Faston 250 with hole
Nominal voltage 12 V
Nominal capacity (10 minute rate) 32 W/2 V
Dimensions
Length 151 mm
Width 51 mm
Height 94 mm
Total Height max. 100 mm
Approx. mass 2.0 kg
Specifications
Dimensions (mm)
Discharge characteristics (20 °C) (Note)
Duration of discharge vs. Discharge current (Note)Capacity (note)
(20 °C)(9.6 V cutoff)
30 minute rate15 minute rate10 minute rate5 minute rate
94 W149 W182 W294 W
Internal resistanceFully charged battery (20 °C)
Approx. 33 mΩ
Temperature dependency of capacity (10 hour rate)
40 °C20 °C0 °C
-15 °C
102 %100 %85 %65 %
Self discharge(20 °C)
Residual capacity after standing 3 months
Residual capacity after standing 6 months
Residual capacity after standing 12 month