DD
DD
DD
Note 1) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.
Note 2) Please consult SMC for networks other than those above.
Communication protocolDN1DN1-X26MJ1CS1CS2SL1SL2UW1UH1CM1CM3
DeviceNet Note 1)
DeviceNet Note 1)
CC-Link
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
CompoNet™ NPN (Positive common)
CompoNet™ PNP (Negative common)
CE-compliant
—
—
—
—
SV1000/2000/3000/4000
VQ1000/2000
SY3000/5000
SY3000/5000 SY3000/5000
Small unit compatible with maximum 16 outputsCompatible with a variety of communication networks
Series EX120 Series EX121 Series EX122
How to Order SI Unit
012
Plug-in
Flat ribbon cable DIN rail mounting
Plug-in DIN rail mounting
DN1EX12 S0Valve interface
Series EX120/121/122For Output
2051
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX12
Note 1) Please note that the version is subject to change.Note 2) Each file can be downloaded from SMC’s website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website. (http://www.smcworld.com).Note 4) Since this is a special product, a manifold part number is not specified. Please consult SMC for the manifold integrated type.
Model EX12-SDN1
DeviceNet™
Release 2.0
125 k/250 k/500 kbps
100 mA or lessSink/NPN (Positive common)
IP20
35 to 85%RH (With no condensation)1500 VAC for 1 min. between whole external terminal and enclosure
2 MΩ or more (500 VDC) between whole external terminal and enclosure
EX120: 110 g or less, EX121: 140 g or less, EX122: 130 g or less
24 VDC+10%/–5%
EDS file
16/16
CE marking
Communication connector 1 pc.,Power supply connector 1 pc.
0/16
Note 4)
EX12-SDN1-X26 EX12-SMJ1
CC-Link
EX12-SCS1EX12-SCS2
EX12-SSL1EX12-SSL2 EX12-SUW1 EX12-SUH1
Ver. 1.10 — — — —
156 k/625 kbps2.5 M/5 M/10 Mbps 750 kbps 28.5 kbps 28.5 kbps 29.4 kbps
32/32 (1 station, remote I/O stations)
Not provided
—
—
Communication speed
Configuration file Note 2)
Terminating resistorFor unit For valve
Output type
Number of outputs
Load
Enclosure
Operating humidity rangeWithstand voltageInsulation resistance
Applicable system
Protocol
Version Note 1)
Internal current consumption (Unit)
StandardsWeight
Accessory
0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)
CompoNet™ Communication Specifications
SI Unit Specifications
ProtocolCommunication speedConfiguration fileI/O occupation area (Inputs/Outputs)Terminating resistor
CompoNet™93.75 kbps/1.5 M/3 M/4 Mbps
EDS file (Download from SMC’s website)0/16
Not provided
Note) For details about the communication speed or each setting instruction, check the operation manual that can be downloaded from SMC website.
Note) Communication connector (for the opposite side) is not provided.
Model
Power supply voltage
Internal current consumption (Unit)
Output
Environment
StandardsWeightAccessory
For unitFor valve
Output type(Valve common polarity)Number of outputsLoadFail safeEnclosure
Operating temperature range
Operating humidity rangeWithstand voltageInsulation resistance
14 to 26.4 VDC24 VDC+10%/–5%
100 mA or less
35 to 85%RH (With no condensation)1500 VAC for 1 min. between whole external terminal and enclosure
2 MΩ or more (500 VDC) between whole external terminal and enclosureCE marking
EX120: 100 g or less, EX121: 120 g or less, EX122: 110 g or less (including accessory)Power supply connector (EX9-CP2) 1 pc.Note)
16 pointsSolenoid valve with/surge voltage suppressor 24 VDC, 2.1 W or less (SMC)
Hold/Clear (Setting via network)IP20
0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)
Sink/NPN output (Positive common) Source/PNP (Negative common)
EX120-SCM1 EX121-SCM1 EX122-SCM1 EX120-SCM3 EX121-SCM3 EX122-SCM3
SI Unit Specifications
OMRON Corp.:CompoBus/S
NKE Corp.:Fieldbus System
NKE Corp.:Fieldbus H System
—
SCS1: 0/16SCS2: 0/8
SSL1: 0/16SSL2: 0/8 0/16 0/16
11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/–5%(Common power supply)
24 VDC±10%(Common power supply)
16 pointsSCS1/SSL1: 16 pointsSCS2/SSL2: 8 points 16 points
Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)Hold/Clear
(Switch setting) ClearClearHold/Clear
(Switch setting) Clear
Co
mm
un
icat
ion
Power supply voltage
Ou
tpu
tE
nvi
ron
men
t
I/O occupation area (Inputs/Outputs)
Fail safe
Operating temperature range
Series EX120/121/122
Panasonic Industrial Devices SUNX Co., Ltd.:
S-Link
2052
9.5
60.8
28.864
29.5
60.8
28.864
60.8
64 1.2 28.8
10.2
5.4
60.8
28.864
5.4
10.2 228.8
60.8
64
10.2
5.4
60.8
28.864
MIL connector (20 pins, socket)
OUT
5.4
60.8
64 10.2 28.8
OUT
5.4
60.8
64 10.2 28.8 2
OUT
28.864
60.8
Communication connector
Valve power supply
Terminal block cover
Position indicator LED
10.2
5.4
Terminal block cover
Position indicator LED
Communication connector
Valve power supply
Terminal block cover
Position indicator LED
Communication connector
Valve power supply
Position indicator LED
Terminal block cover
Screw terminal block
Position indicator LED
Terminal block cover
Power supply connector
Communication connector
Position indicator LED
Terminal block cover
Screw terminal block
DIN rail mounting bracket
MIL connector(20 pins, socket)
Position indicator LED
Terminal block cover
Screw terminal block
DIN rail mounting bracket
MIL connector(20 pins, socket)
Position indicator LED
Terminal block cover
Power supply connector
Communication connector
MIL connector(20 pins, socket)
DIN rail mounting bracket
Terminal block cover
Position indicator LED
Screw terminal block
DIN rail mounting bracket
Terminal block cover
Position indicator LED
Power supply connector
Communication connector
DIN rail mounting bracket
EX120EX120-SMJ1, SCS,SSL, SUW1, SUH1
EX120-SDN1(-X26) EX120-SCM
EX121EX121-SMJ1, SCS,SSL, SUW1, SUH1
EX121-SDN1(-X26) EX121-SCM
EX122EX122-SMJ1, SCS,SSL, SUW1, SUH1
EX122-SDN1(-X26) EX122-SCM
SI Unit Dimensions/Parts Description
For Output Series EX120/121/122
2053
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX12
How to Order Options (For EX12-SCM)
Cable identification label(Flat cable: Black, blue, white, red)
Black
Lock lever
Black
Lock lever
Cable identification label(Flat cable: Black, blue, white, red)
Power supply connector: T-branch type power supply connector.
EX9-CP3
Power supply connector: Straight type power supply connector. This connector is supplied at shipment.
EX9-CP2
Communication connector: Terminal block connector for round cable (VCTF).Use this connector for the VCTF cable.
EX9-CCM2
Communication connector: Press-in connector for flat cable.Use this connector for the standard dedicated flat cable.
EX9-CCM1
Series EX120/121/122
2054
DD
D
D
D
3Common power supply of unit and valveEnclosure IP65Compatible with the VQ valves
Mounting specifications
SL1SL2UW1UH1
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
—
—
—
—
CE-compliant
CE-compliant
DN1DN1-X26MJ1CS1CS2
DeviceNet Note)
DeviceNet Note)
CC-Link
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
MJ1 CC-Link
CE-compliant
Series EX123VQ2000/4000/5000
Series EX124VQ2000/4000/5000
Series EX126
SV1000/2000/3000
SY3000/5000
VQC1000/2000/4000
Note) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.
Enclosure IP65 (EX123, EX124), IP67 (EX126)Maximum 16 outputs
How to Order SI Unit
Unit specifications
SL1EX12 SU3Communication protocol
UD
Mount a unit to the U side of the manifold
Mount a unit to the D side of the manifold
Unit specifications
4Separate power supply of unit and valve Enclosure IP65Compatible with the VQ valves
UD
Mount a unit to the U side of the manifold
Mount a unit to the D side of the manifold
DN1EX12 SU4
Mounting specifications
Communication protocol
Unit specifications
6Separate power supply of unit and valve Enclosure IP67 Compatible with the SY/SV/VQC valves
D Mount a unit to the D side of the manifold
MJ1EX12 SD6
Mounting specifications
Communication protocol
Series EX123/124/126For Output
2055
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX12
SI Unit Specifications
The electrical specification is the same for EX12. Refer to page 2052.The weight of the EX123, 124, or 126 is 240g or less.4 unit mounting screws (M4 x 10) are included when shipped.
How to Order Options
Fuse for replacementA fuse for replacement used for EX126D-SMJ1.
EX9 FU20Applicable model
Rated current
EX126D-SMJ1
2.0 A
Dripproof plug assemblyUse for the unused conduit port (G1/2).
AXT100 B04A
Fuse
Series EX123/124/126
2056
16.8
Housing cover
19.8
65.7
68.2
6.6
30.4
42
(72.
5)
5.5
67
114
35.3
19.8
4 x G1/2Conduit port
(72.
5)
5.5
56.4
19
11.6
53.8
19
19.8
67
114
Housing cover
Position indicator LEDScrew terminal block
Housing cover diagram
EX123: 2 x G1/2EX124: 4 x G1/2Conduit port
Housing cover diagram
Position indicator LED Screw terminal block
Housing bottom diagram
Power supply fuse for solenoid valve
Power supply fuse for communication
Note) The housing cover of the EX124U/D-SMJ1 is the same as that of the EX126D-SMJ1.
EX126D-SMJ1
SI Unit Dimensions/Parts Description
EX123-S, EX124-S
For Output Series EX123/124/126
2057
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX12
DN1EX140 SCommunication protocol
DN1MJ1CS1CS2SL1SL2UW1UH1
DeviceNet™
CC-Link
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)
Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
—
—
—
—
CE-compliant
Note) Please consult SMC for networks other than those above.
SZ3000 SQ1000/2000
Thinner unit with low heightMaximum 16 outputs
How to Order SI Unit
Series EX140For Output
2058
33.4
(36)(11.
5) 34.494.5
34.494.5
33.4
Position indicator LEDPosition indicator LED
Power supply connector
Communication connectorScrew terminal block
Standards
Weight
Accessory
EX140-SDN1 EX140-SMJ1 EX140-SCS1EX140-SCS2
EX140-SSL1EX140-SSL2
EX140-SUW1 EX140-SUH1
SI Unit Specifications
Model
Communication speed
Configuration file Note 2)
Terminating resistor
For unit
For valve
Output type
Number of outputs
Load
Enclosure
Operating humidity range
Withstand voltage
Insulation resistance
Applicable system
Protocol
Version Note 1)
Internal current consumption (Unit)
Fail safe
Operating temperaturerange
I/O occupation area (Inputs/Outputs)
Co
mm
un
icat
ion
Ou
tpu
tE
nvi
ron
men
t
Power supply voltage
DeviceNet™
Release 2.0
125 k/250 k/500 kbps
11 to 25 VDC
16 outputs
Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)
24 VDC+10%/–5%
EDS file
0/16
Hold/Clear(Switch setting)
CE marking
Communication connector 1 pc.,Power supply connector 1 pc.
32/32(1 station, remote
I/O stations)
CC-LinkOMRON Corp.:CompoBus/S
Panasonic Industrial Devices SUNX Co., Ltd.:
S-Link
NKE Corp.:Fieldbus System
NKE Corp.:Fieldbus H System
Ver. 1.10 — — — —
156 k/625 kbps2.5 M/5 M/10 Mbps
750 kbps 28.5 kbps
—
28.5 kbps 29.4 kbps
SCS1: 0/16SCS2: 0/8
SSL1: 0/16SSL2: 0/8
Not provided
0/16
15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/–5%(Common
power supply)
100 mA or less
Sink/NPN (Positive common)
IP20
35 to 85%RH (With no condensation)
1500 VAC for 1 min. between whole external terminal and enclosure
2 MΩ or more (500 VDC) between whole external terminal and enclosure
80 g or less
SCS1/SSL1: 16 outputsSCS2/SSL2: 8 outputs
0 to +55°C (Valve 8 points ON)0 to +50°C (Valve 16 points ON)
16 outputs
—
—
Clear
24 VDC±10%(Common power supply)
Note 1) Please note that the version is subject to change.Note 2) Each file can be downloaded from SMC website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
SI Unit Dimensions/Parts Description
EX140-SMJ1, SCS, SSL, SUW1, SUH1 EX140-SDN1
For Output Series EX140
2059
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX140
®
RoHS
Communication protocolDN3DN4DN5DN6MJ3MJ5
DeviceNet™ (32 points Sink/NPN (Positive common))
DeviceNet™ (16 points Sink/NPN (Positive common))
DeviceNet™ (32 points Source/PNP (Negative common))
DeviceNet™ (16 points Source/PNP (Negative common))
CC-Link (32 points Sink/NPN (Positive common))
CC-Link (32 points Source/PNP (Negative common))
Note) Please consult SMC for networks other than those above.
SJ2000/3000 S0700
EX180-C1 EX180-C2
Note) S0700 is not yet UL-compatible.
Thinner unit with low heightMaximum 32 outputs
How to Order SI Unit
DN3EX180 SCommunication connector typeNil
AT-branch type
Straight type
Note) Communication and power supply connectors are included.
How to Order Options
Communication connectorConnector for the network cable, included when shipped.
EX180 C DN 1
DNMJ
Communicationprotocol
For EX180-SDNFor EX180-SMJ
12
Communication connector typeT-branch typeStraight type
Power supply connectorConnector for power supply, included when shipped.
EX180 CP1
Series EX180For Output
2060
EX180-SDN5EX180-SDN6
EX180-SMJ5EX180-SDN3EX180-SDN4
EX180-SMJ3
SI Unit Specifications
Model
Co
mm
un
icat
ion
Ou
tpu
tE
nvi
ron
men
t
Communication speed
Configuration file Note 2)
Terminating resistor
For unit
For valve
Output type
Number of outputs
Load
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Applicable system
Protocol
Version Note 1)
Power supply voltage
Internal current consumption (Unit)
I/O occupation area (Inputs/Outputs)
Fail safe
Standards
Weight
Accessory
DeviceNet™
Release 2.0
125 k/250 k/500 kbps
Not provided
11 to 25 VDC
0.1 A or less
EDS file
Communication connector 1 pc.,Power supply connector 1 pc.
Communication connector 1 pc.,Power supply connector 2 pcs.
Ver. 1.10
—
CC-Link
32/32 (1 station)
32 outputs
15 to 30 VDC
SDN3: 32 outputsSDN4: 16 outputs
SDN5: 32 outputsSDN6: 16 outputs
Series SJ2000/3000, S0700 manifold valves
Series SJ2000/3000, S0700 manifold valves
IP20
–10 to 50°C
35 to 85%RH (With no condensation)
500 VAC for 1 min. between whole external terminal and FG
10 MΩ or more (500 VDC) between whole external terminal and FG
CE marking, UL (CSA)
110 g or less (including accessory)
Source/PNP (Negative common)Sink/NPN (Positive common) Source/PNP (Negative common)Sink/NPN (Positive common)
24 VDC±10%/–5%
156 k/625 kbps2.5 M/5 M/10 Mbps
Built into the unit (Switch setting, 110 Ω)
Hold/Clear(Switch setting)
Note 1) Please note that the version is subject to changeNote 2) Each file can be downloaded from SMC website (http://www.smcworld.com).Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website
(http://www.smcworld.com).Note 4) The EX180-SDN1/2 cannot be mounted on the manifold for the EX180-SDN3/4/5/6. Additionally, the EX180-SDN3/4/5/6 cannot be
mounted on the manifold for the EX180-SDN1/2.Note 5) The EX180-SMJ1 cannot be mounted on the manifold for the EX180-SMJ3/5. Additionally, the EX180-SMJ3/5 cannot be mounted on the manifold
for the EX180-SMJ1.
SDN3: 0/32SDN4: 0/16
SDN5: 0/32SDN6: 0/16
For Output Series EX180
2061
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX180
93.3
80
77
42.3
93.3
80
77
42.3
EX180-SMJ3, SMJ5
EX180-SDN3, SDN4, SDN5, SDN6
SI Unit Dimensions/Parts Description
(39.
7)
30.9
Power supply connector(For solenoid valve)
Power supply connector(Control unit power supply for SI unit)
Communication connector
M3Ground terminal
Before mounting connector (accessory)
Power supply connector(For solenoid valve)
Communication connector
Before mounting connector (accessory)
M3Ground terminal
(39.
7)
30.9
Series EX180
2062
®
RoHS
IP67IP67 IP67 IP40
Top ported valve Bottom ported valve Side ported valveMixed valve sizes manifold
7 mm width valve
Applicable Fieldbus protocols
Series EX260Fieldbus System
(Output device for driving 5 port solenoid valves)
Daisy-chain wiringcommunication
Space-saving InstallationSpace-saving InstallationCompact
28mm
IP67∗∗ For units with D-sub connector, and when connected to S0700 manifolds, it is IP40.
Drives up to 32 solenoids
2063
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260
PWR
BUS IN
BUS OUT
E3/5
1 P
E3/5
1 P
B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2
PWR
BUS IN
BUS OUT
E3/5
1 P
E3/5
1 P
B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2
Product Specification Variations
M12 communicationconnector(PROFIBUS DP)
D-sub communicationconnector(PROFIBUS DP)
16
32
PNP
NPN
M12
D-sub
16
32
PNP
NPN
M12
16
32
PNP
NPN
M12
16
32
PNP
NPN
M12
16
32
PNP
NPN
M12
28.2 mm81 mm
Communication connector examples
Fieldbus
EX260
16
32
PNP
NPN
M12
Manifold length is shortened by the small fieldbus output module (SI unit).
Wiring and piping from the same direction is possible.(for side ported)Effective for installation in locations where space is limited above the valve.
Existing model EX250
External branch connector is not necessary. Daisy-chain wiring is possible. Reduced wiring space
Branch connectorExisting model (EX250)
External terminating resistor is not necessary.(Only available for M12 PROFIBUS DP, CC-Link communication connectors)
ON/OFF switching is possible with an internal terminating resistor. External terminating resistor is not necessary.
External terminating resistor
Internal terminatingresistor
SI unit
Number ofoutputs
Outputpolarity
Communicationconnector
2064
SY3000
SY5000
S0700
SV1000
SV2000
SV3000
VQC1000
VQC2000
VQC4000
0.35 (standard)0.1 (with power-
saving circuit)32
32
32
24
0.6
0.4 (standard)
1.0 (standard)
0.35
IP67
IP40
IP67
IP67
0.19
0.17
0.39
0.35
0.18
0.21
0.30
0.30
0.38
1.6
3.6
0.37
1.1
2.4
4.3
1.0
3.2
7.3
SeriesPower
consumption(W)
Enclosure StandardsFlow-rate characteristics (4/2→5/3)
C [dm3/(s·bar)] b
Maximumnumber ofsolenoids
Applicable Valve Series
Note) For units with D-sub communication connector, it is IP40.
®
Side ported Side ported
Bottom ported
Top ported<Example of Use>
Valve piping direction variations
Series SY3000/5000 Pressure switch
Piping is possible from 3 directions.
Mixed mounting of top ported and side ported is possible.
By mounting top ported valves on side ported and bottom ported type manifolds, it is possible to detect the output of the A/B port with a pressure switch.
Valves can be freely connected up to 24 stations. Mixed valve sizes manifoldValves of different sizes,
SY3000 and SY5000, can be mounted on the same manifold.
It is possible to connect only the number of valves required, from 1 to 24 stations, to suit the application.(Maximum number of solenoids connected: 32)
7 mm width valves can be connected.
It is possible to connect only the number of 7 mm width valves required, from 1 to 24 stations. (Maximum number of solenoids connected: 32)
Series S0700
2065
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260
M12
DN1DN2DN3DN4PR1PR2PR3PR4PR5PR6PR7PR8MJ1MJ2MJ3MJ4EC1EC2EC3EC4PN1PN2PN3PN4EN1EN2EN3EN4
DeviceNet™
PROFIBUS DP
EtherCAT
PROFINET
Note) Enclosure is IP40 when the communication connector is D-sub.
SI unit output polarity
32
16
32
16
32
16
32
16
32
16
32
16
32
16
M12
M12
D-sub Note)
M12
M12
EtherNet/IP™ M12
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
Source/PNP (Negative common)Sink/NPN (Positive common)
QANQA
QBNQB
NANNA
NBNNB
NCNNC
NDNND
VANVA
VBNVB
DANDA
DBNDB
FANFA
FBNFB
EANEA
EBNEB
Communication protocol
Compact design Compact design for space saving
Number of outputs Each 32/16 digital output type available in the series
Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP40.)
Output polarity Each negative common (PNP) / positive common (NPN) type available in the series
Internal terminating resistorON/OFF switching is possible with an internal terminating resistor for communication.(Only for units compatible with M12 PROFIBUS DP, CC-Link communication connectors)
SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000
DD
DD
How to Order SI Units
PR1EX260 S
Note)
Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.
CC-Link
®
RoHS
ProtocolSymbol Number of outputs Communication connector Manifold symbol
Series EX260SI Unit/For Output
2066
SI Unit Specifications
Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4
125 k/250 k/500 kbps 156 k/625 k/2.5 M/5 M/10 Mbps
M12Built-in
—
—22.8 to 26.4 VDC
11 to 25 VDC100 mA or less
Applicablesystem
I/O occupation area (Inputs/Outputs)
Communication speed
Power supplyfor controlPower supply for output
Communication connector specificationTerminating resistor switch
Power supply for communication
Output
Environmental resistance
StandardsWeight
Mounting screwAccessories
IP67 IP40 IP67–10 to 50°C
35 to 85%RH (No condensation)500 VAC for 1 minute between terminals and housing
10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housingCE marking, UL (CSA) compatible
200 g2 pcs.
24 VDC
Power supply voltageInternal current consumptionPower supply voltagePower supply voltageInternal current consumption
Protocol
Version Note 1)
Configuration file Note 3)
Supplied current
Output type
Number of outputs
LoadSupplied voltage
EnclosureOperating temperature rangeOperating humidity rangeWithstand voltageInsulation resistance
Seal cap (for M12 connector socket)
Source/PNP(Negative common)
Sink/NPN(Positive common)
Source/PNP(Negative common)
Sink/NPN(Positive common)
Source/PNP(Negative common)
Sink/NPN(Positive common)
SPR1: 32 pointsSPR3: 16 points
SPR2: 32 pointsSPR4: 16 points
SPR5: 32 pointsSPR7: 16 points
SPR6: 32 pointsSPR8: 16 points
SDN1: 32 pointsSDN3: 16 points
SDN2: 32 pointsSDN4: 16 points
SPR1: 0/32SPR3: 0/16
SPR2: 0/32SPR4: 0/16
SPR5: 0/32SPR7: 0/16
SPR6: 0/32SPR8: 0/16
SDN1: 0/32SDN3: 0/16
SDN2: 0/32SDN4: 0/16
SMJ1: 32/32SMJ3: 32/32(1 station, remote I/O stations)
SMJ2: 32/32SMJ4: 32/32(1 station, remote I/O stations)
SPR1: Max. 2.0 ASPR3: Max. 1.0 A
SPR2: Max. 2.0 ASPR4: Max. 1.0 A
SPR5: Max. 2.0 ASPR7: Max. 1.0 A
SPR6: Max. 2.0 ASPR8: Max. 1.0 A
SDN1: Max. 2.0 ASDN3: Max. 1.0 A
SDN2: Max. 2.0 ASDN4: Max. 1.0 A
EX9-AWTS (1 pc.) — EX9-AWTS (1 pc.)
D-sub M12None Built-in
Volume 1(Edition 3.5)Volume 3(Edition 1.5)
9.6 k/19.2 k/45.45 k/93.75 k/187.5 k/500 k/1.5 M/3 M/6 M/12 Mbps
21.6 to 26.4 VDC100 mA or less
—— —
—
21.6 to 26.4 VDC100 mA or less
PROFIBUS DP DeviceNet™ CC-Link
DP-V0 Ver.1.10
—GSD file EDS file
Source/PNP(Negative common)
Sink/NPN(Positive common)
SMJ1: 32 pointsSMJ3: 16 points
SMJ2: 32 pointsSMJ4: 16 points
SMJ1: Max. 2.0 ASMJ3: Max. 1.0 A
SMJ2: Max. 2.0 ASMJ4: Max. 1.0 A
Solenoid valve with protective circuit for surge voltage of 24 VDC/1.5 W or less (SMC)
Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4
Applicablesystem
I/O occupation area (Inputs/Outputs)Communication speed Power supplyfor controlPower supply for output
Communication connector specificationTerminating resistor switch
Power supply for communication
Output
Environmental resistance
StandardsWeight
Mounting screwAccessories
IP67–10 to 50°C
35 to 85%RH (No condensation)500 VAC for 1 minute between terminals and housing
10 MΩ or more (500 VDC measured via megohmmeter) between terminals and housingCE marking, UL (CSA) compatible
200 g2 pcs.
24 VDC
Power supply voltageInternal current consumptionPower supply voltagePower supply voltageInternal current consumption
Protocol
Version Note 1)
Configuration file Note 3)
Supplied voltage
Output type
Number of outputs
Load
Supplied voltage
EnclosureOperating temperature rangeOperating humidity rangeWithstand voltageInsulation resistance
Seal cap (for M12 connector socket)
Source/PNP(Negative common)
Sink/NPN(Positive common)
Source/PNP(Negative common)
Sink/NPN(Positive common)
Source/PNP(Negative common)
Sink/NPN(Positive common)
SEC1: 32 pointsSEC3: 16 points
SEC2: 32 pointsSEC4: 16 points
SPN1: 32 pointsSPN3: 16 points
SPN2: 32 pointsSPN4: 16 points
SEN1: 32 pointsSEN3: 16 points
SEN2: 32 pointsSEN4: 16 points
SEC1: 0/32SEC3: 0/16
SEC2: 0/32SEC4: 0/16
SPN1: 0/32SPN3: 0/16
SPN2: 0/32SPN4: 0/16
SEN1: 16/32SEN3: 16/16
SEN2: 16/32SEN4: 16/16
SEC1: Max. 2.0 ASEC3: Max. 1.0 A
SEC2: Max. 2.0 ASEC4: Max. 1.0 A
SPN1: Max. 2.0 ASPN3: Max. 1.0 A
SPN2: Max. 2.0 ASPN4: Max. 1.0 A
SEN1: Max. 2.0 ASEN3: Max. 1.0 A
SEN2: Max. 2.0 ASEN4: Max. 1.0 A
EX9-AWTS (1 pc.)
Volume 1(Edition 3.8)Volume 2(Edition 1.9)
21.6 to 26.4 VDC100 mA or less
22.8 to 26.4 VDC——
M12None
10 M/100 Mbps Note 2)100 Mbps Note 2)
EtherCAT Note 2) EtherNet/IP™ Note 2)
Conformance Test Record V.1.1
XML file
PROFINET Note 2)
PROFINET SpecificationVersion 2.2
GSD file EDS file
Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.5 W or less (SMC)
Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.0 W or less (SMC)
Solenoid valve with protective circuit for surgevoltage of 24 VDC/1.5 W or less (SMC)
Note 1) Please note that the version is subject to change.Note 2) Use a CAT5 or higher transmission cable for EtherCAT, PROFINET, EtherNet/IP™.Note 3) Each file can be downloaded from the SMC website, http://www.smcworld.com
For Output Series EX260
2067
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260
D-sub communication connector typeM12 communication connector type
90.9
28.2
102.
4 90.9
102.
4
28.221 20.6 16.4 9
76.5
28.75 29.25 9
76.5
SI Unit Dimensions
Part no.
Communication protocol
EX260-SPR1/-SPR2 -SPR3/-SPR4
PROFIBUS DP
5 pins, socket, B code
5 pins, plug, B code
5 pins, plug, A code
Note) The setting switch varies depending on the model. Refer to the operation manual for details. Please download it via the SMC website, http://www.smcworld.com
EX260-SDN
DeviceNet™
5 pins, socket, A code
5 pins, plug, A code
4 pins, plug, A code
EX260-SMJ
CC-Link
EX260-SECEX260-SPNEX260-SEN
EtherCATPROFINET
EtherNet/IP™
M3
Communication connector (M12) BUS OUT
Communication connector (M12) BUS IN
Ground terminal
Power connector (M12)
<Setting switch>• Address switch• Communication speed switch• Terminating resistor switch• Others
<LED indication>• Communication state• Unit power supply state• Valve power supply state
Part no.
Communication protocol
EX260-SPR5/-SPR6/-SPR7/-SPR8PROFIBUS DP
M3
9 pins, socket
5 pins, plug, A code
Ground terminal
Communication connector (D-sub) BUS IN/OUT
Power connector (M12)
D-sub communication connector type
Functions of SI Unit Parts
<Connector>M12 communication connector type
<LED indication and setting switch>
5 pins, socket, A code
4 pins, plug, A code
5 pins, plug, B code
4 pins, socket, D code
4 pins, socket, D code
5 pinsNote1), 4 pinsNote2), plug, A code
Note 1) For EtherCAT, PROFINETNote 2) For EtherNet/IP™
Series EX260
2068
WhiteOrangeWhite
Green
Accessories
q Communication cable with connector
For SI units compatible with PROFIBUS DP, DeviceNet™, CC-Link
For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™
Refer to page 2153 for details. 020EX9 AC ENCable length (L)
1000 [mm] 2000 [mm] 3000 [mm] 5000 [mm]10000 [mm]
010020030050100
PSRJ
M12 plug (straight) ⇔ RJ-45 connectorPSRJ
1
3 4
2
Plug connectorpin arrangement
D codeConnections (Straight cable)
M12 RJ-45
ø6.
7
47.3 45L
Plug connectorpin arrangement
12345678
Terminalno.1234
12345678
Terminalno.
Shield
Pair
Pair
Core wire colors
Connector specification
For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™
PCA 1446566
For SI units compatible with EtherCAT, PROFINET, EtherNet/IP™
PCA 1446553
5000 [mm]1446566Cable length
Fieldwireable connector
(ø6.
5)
50500047.3
ø14
.8
Plug connectorpin arrangement
D code
12
3 4
M12SPEEDCON
ø17
.5
ø19
≈ 61
Width acrossflats 16
M12
For Output Series EX260
Plug connectorpin arrangement
D code
12
3 4
12
34
White: RD+
Blue: RD–
Yellow: TD+
Orange: TD–
Connections
Terminalno. Wire guide color
Width across flats 13
2069
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260
w Power cable with connector (for SI units)
Accessories
EX500 AP
2
4 3
Socket connectorpin arrangement
A code
Socket connectorpin arrangement
A code
1
12
34
5
Terminalno.
Core wire colors
M12
ø14
.9
4834
18
L
ø6
30 5
50
Connections (PROFIBUS DP/EtherCAT)
Cable length (L)1000 [mm]5000 [mm]
010050
Connector specificationStraightAngle
SA
S050
For SI units compatible with PROFIBUS DP, DeviceNet™, EtherCAT, PROFINET, EtherNet/IP™
e Seal cap: For M12 connector socket
EX9 AW
Use this on ports that are not being used for communication connector (M12 connector socket).Use of this seal cap maintains the integrity of the IP67 enclosure.Note) Tighten the seal cap with the prescribed tightening torque. (For M12: 0.1 N·m)
TSConnector type
For M12 connector socket (10 pcs.)For M12 connector socket
M12 x 1
14
10.2
14
Brown: 24 VDC +10%/–5% (Solenoid valve power supply)White: 0 V (Solenoid valve power supply)
Blue: 24 VDC ±10% (Control power supply)Black: 0 V (Control power supply)
Gray: Not connected
12
34
5
Terminalno.
Core wire colors
Connections (DeviceNet™, EtherNet/IP™)
Brown: Not connected Note 1), 24 VDC ±10% (Control power supply) Note 2)White: 24 VDC +10%/–5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2)Black: 0 V (Solenoid valve power supply)
Gray: Not connected
Straight connector type
For SI units compatible with CC-Link
Straight connector type
2
4 3
51
M12
31.3
28.3
30 5
50L
ø6
Angle connector type
TS
5
EX9 AC 1Cable length (L)
1000 [mm]3000 [mm]5000 [mm]
010030050
050
SPEEDCON
SPEEDCON
PCACable length (L)
1500 [mm]3000 [mm]5000 [mm]
140180414018051401806
1401804
PCACable length (L)
1500 [mm]3000 [mm]5000 [mm]
140180714018081401809
1401807
2
4 3
5 1
Socket connectorpin arrangement
B code
M12 48.1
L
30
50
5
ø6.
4
Connections1
23
45
Terminalno.
Cable corewire colors
4 3
21
4 3
21
ø14
.8
M12SPEEDCON
M12SPEEDCON
ø14
.8
44.5 L 50
50L44.5
ø5.
0±0.
15ø
5.0±
0.15
5
5
Socket connectorpin arrangement
A code
Socket connectorpin arrangement
B code
Note 1) For DeviceNet™Note 2) For EtherNet/IP™
Brown: 24 VDC +10%/–5% (Solenoid valve power supply)White: 0 V (Solenoid valve power supply)
Blue: 24 VDC ±10% (Control power supply)Black: 0 V (Control power supply)
Gray: Not connected
Series EX260
2070
Design/Selection
1. Use this product within the specification range.Using beyond the specified specifications range can causefire, malfunction, or damage to the system.Check the specifications before operation.
2. When using for an interlock circuit:• Provide a multiple interlock system which is
operated by another system (such as mechanical protection function).
• Perform an inspection to confirm that it is working properly.
This may cause possible injury due to malfunction.
WarningMounting
4. When lifting a large size manifold solenoid valve unit, take care to avoid causing stress to the valve connection joint.The connection parts of the unit may be damaged. Because the unit may be heavy, carrying and installation should be performed by more than one operator to avoid strain or injury.
5. When placing a manifold, mount it on a flat surface.Torsion in the whole manifold can lead to trouble such as air leakage or defective insulation.
Wiring
1. Check the grounding to maintain the safety of the reduced wi r ing sys tem and for an t i -no ise performance.Provide a specific grounding as close to the unit as possible to minimize the distance to grounding.
2. Avoid repeatedly bending or stretching the cable and applying a heavy object or force to it.Wiring applying repeated bending and tensile stress to the cable can break the circuit.
3. Avoid miswiring.If miswired, there is a danger of malfunction or damage to the reduced wiring system.
4. Do not wire while energizing the product.There is a danger of malfunction or damage to the reduced wiring system or output device.
5. Avoid wiring the power line and high pressure line in parallel.Noise or surge produced by signal line resulting from the power line or high pressure line could cause malfunction.Wiring of the reduced wiring system or output device and the power line or high pressure line should be separated from each other.
6. Check the wiring insulation.Defective insulation (contact with other circuits, improper insulation between terminals, etc.) may cause damage to the reduced wiring system or output device due to excessive voltage and current.
7. When a reduced wiring system is installed in machinery/equipment, provide adequate protection against noise by using noise filters, etc.Noise in signal lines may cause malfunction.
1. When applicable to UL, use a Class 2 power supply unit conforming to UL1310 for direct current power supply.
2. Use this product within the specified voltage range.Using beyond the specified voltage range is likely to cause the units and connecting devices to be damaged or to malfunction.
3. Do not install a unit in a place where it can be used as a foothold.Applying any excessive load such as stepping on the unit by mistake or placing a foot on it, will cause it to break.
4. Keep the surrounding space free for maintenance.When designing a system, take into consideration the amount of free space needed for performing maintenance.
5. Do not remove the name plate.Improper maintenance or incorrect use of operation manual can cause failure and malfunction. Also, there is a risk of losing conformity with safety standards.
1. When handling and assembling units:• Do not apply excessive force to the unit when
disassembling.The connecting portions of the unit are firmly joined with seals.
• When joining units, take care not to get fingers caught between units.Injury can result.
2. Do not drop, bump, or apply excessive impact. Otherwise, the unit can become damaged, malfunction, or fail to function.
3. Observe the tightening torque range.Tightening outside of the allowable torque range will likely damage the screw.
IP67 cannot be guaranteed if the screws are not tightened to the specified torque.
Mounting
Series EX260Specific Product Precautions 1Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website,http://www.smcworld.com
Caution
Caution
Caution
Caution
2071
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260
Wiring
Operating Environment
1. Do not use in an atmosphere containing an inflammable gas or explosive gas.Use in such an atmosphere is l ikely to cause a fire or explosion. This system is not explosion-proof.
Operating Environment
2. Provide adequate protection when operating in locations such as the following.Failure to do so may cause damage or malfunction.The effect of countermeasures should be checked in individual equipment and machine.1) Where noise is generated by static electricity, etc.2) Where there is a strong electric field3) Where there is a danger of exposure to radiation4) When in close proximity to power lines or high voltage lines
3. Do not use in an environment where oil and chemicals are used.Operating in environments with coolants, cleaning solvents, various oils or chemicals may cause adverse effects (damage, malfunction) to the unit even in a short period of time.
4. Do not use in an environment where the product could be exposed to corrosive gas or liquid.This may damage the unit and cause it to malfunction.
5. Do not use in locations with sources of surge generation.Installation of the unit in an area around the equipment (electromagnetic lifters, high frequency induction furnaces, welding machine, motors, etc.), which generates the large surge voltage could cause to deteriorate an internal circuitry e lement of the uni t or resul t in damage. Implement countermeasures against the surge from the generating source, and avoid touching the lines with each other.
6. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in your system.
7. Keep dust, wire scraps and other extraneous material from getting inside the product.This may cause malfunction or damage.
8. Mount the unit in such locations, where no vibration or shock is affected.This may cause malfunction or damage.
9. Do not use in places where there are cyclic temperature changes.In case that the cycl ic temperature is beyond normal temperature changes, the internal unit is likely to be adversely effec-ted.
10. Do not use in direct sunlight.Do not use in direct sunlight. It may cause malfunction or damage.
11. Use this product within the specified ambient temperature range.This may cause malfunction.
12. Do not use in places where there is radiated heat around it.Such a place is likely to cause malfunction.
1. Select the proper type of enclosure according to the environment of operation.IP67 is achieved when the following conditions are met.1) Provide appropriate wiring between all units using electrical
wiring cables, communication connectors and cables with M12 connectors.
2) Suitable mounting of each unit and manifold valve.3) Be sure to mount a seal cap on any unused connectors.If using in an environment that is exposed to water splashes, please take measures such as using a cover.When the enclosure is IP40, do not use in an operating environment or atmosphere where it may come in contact with corrosive gas, chemical agents, seawater, water, or water vapor. When connected to the EX260-SPR5/6/7/8, manifold enclosure is IP40.
Series EX260Specific Product Precautions 2Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website, http://www.smcworld.com
Caution
Caution
Caution
Warning
8. When connecting wires of output device, prevent water, solvent or oil from entering inside the connector section. This can cause damage, equipment failure or malfunction.
9. Avoid wiring patterns in which excessive stress is applied to the connector.This may cause malfunction or damage to the unit due to contact failure.
10. Select connectors that are ø16 or less if mounting manifolds directly using fieldwireable connectors for SI unit power supply wiring.Using large diameter connectors causes interference with the mounting surface.The following cables with connectors are recommended.
For EX260-SPR/-SDN/-SEC/-SPN/-SEN<Cable with connector> EX500-AP- PCA-1401804/-1401805/-1401806
For EX260-SMJ<Cable with connector> EX9-AC-1 PCA-1401807/-1401808/-1401809
2072
Adjustment/Operation
Warning1. Do not perform operation or setting with wet hands.
There is a risk of electrical shock.
Maintenance
1. Do not disassemble, modify (including circuit board replacement) or repair this product.Such actions are likely to cause injuries or breakage.
2. When an inspection is performed,• Turn off the power supply.• Stop the air supply, exhaust the residual pressurein
piping and verify that the air is released before performing maintenance work.Unexpected malfunction of system components and injury can result.
TrademarkDeviceNet™ is a trademark of ODVA.EtherNet/IP™ is a trademark of ODVA.EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
1. Use a watchmakers’ screwdriver with thin blade for the setting of each switch of the SI unit.When setting the switch, do not touch other unrelated parts.This may cause parts damage or malfunction due to a short circuit.
2. Provide adequate setting for the operating conditions.Failure to do so could result in malfunction.Refer to the operation manual for setting of the switches.
3. For details on programming and address setting, refer to the manual from the PLC manufacturer.The content of programming related to protocol is designed by the manufacturer of the PLC used.
4. For the EX260-SPN, the side of the SI unit may become hot.It may cause burns.
1. When handling and replacing the unit:• Do not apply excessive force to the unit when
disassembling.The connecting portions of the unit are firmly joined with seals.
• When joining units, take care not to get fingers caught between units.Injury can result.
2. Perform periodic inspection.Unexpected malfunction in the system composition devices is likely to occur due to malfunction of machinery or equipment.
3. After maintenance, make sure to perform an appropriate functionality inspection.In cases of abnormality such as faulty operation, stop operation. Unexpected malfunction in the system composition devices is likely to occur.
4. Do not use benzene and thinner for cleaning units.Damage to the surface or erasure of the display can result.Wipe off any stains with a soft cloth.If the stain is persistent, wipe off with a cloth soaked in a dilute solution of neutral detergent and wrung out tightly, and then finish with a dry cloth.
Other
1. Refer to the catalog of each series for Common Precautions and Specific Product Precautions on manifold solenoid valves.
Series EX260Specific Product Precautions 3Be sure to read before handling. Refer to front matter 53 for Safety Instructions, Pages 3 to 8 and “Operation Manual” for 3/4/5 Port Solenoid Valve Precautions. The Operation Manual can be downloaded from the SMC website,http://www.smcworld.com
Caution
Caution
Caution
Warning
2073
EX12
EX140
EX180
EX260
EX250
EX600
EX500
EX510PCAEX
EX260