Prepared especially for: Building owners, college housing directors, military procurement offi- cers, management companies, archi- tects, engineers, specification writers, contractors and builders. For vended and commercial homestyle laundry equipment facilities in apartments, residence halls, condominiums, cooperatives, hotels, motels, military installations, campgrounds, RV parks, senior citizen residences, truck stops and marinas.
Transcript
Page 1: For vended and commercial homestyle laundry equipment ...

Prepared especially for:Building owners, college housingdirectors, military procurement offi-cers, management companies, archi-tects, engineers, specification writers,contractors and builders.

For vended and commercial homestyle laundry equipment

facilities in apartments, residence halls, condominiums,

cooperatives, hotels, motels, military installations,

campgrounds, RV parks, senior citizen residences,

truck stops and marinas.

Page 2: For vended and commercial homestyle laundry equipment ...
Page 3: For vended and commercial homestyle laundry equipment ...

Table of Contents

ProductsOur 90 year reputation for quality products with innova-tive technology is supported by our position as NorthAmerica's largest manufacturer of commercial laundryequipment.

SystemsOur customized systems for coin or smart-card vendingoptions include NetMasterTM and CardMate PlusTM softwarewith a NetMaster ControlTM for computerized programmingand data retrieval.

ServicesA national network of Speed Queen Route Operators is inplace to provide valuable information about SpeedQueen’s exceptional choices of laundry products, systemsand service. Sales, service and warranty is available fromthis national network of authorized Speed Queen RouteOperators.

When equipping a laundry room the decisions seem endless. With Speed Queen's combinationof quality products, innovative systems, and adependable Customer One Service program, youcan be confident that Speed Queen can meet allyour laundry needs and you'll be happy with theresults.

For information and solutions to questions about

multi-housing laundry equipment,

visit our website at

www.speedqueen.comor call 1-800-345-5649

or look in the yellow pages for a

Speed Queen Route Operator nearest you!

Exceptional Choices from Speed Queen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Basics in Establishing a Laundry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Laundry Room Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Equipment Sizing Ratios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Suggested Floor Plans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Installation Suggestions/Equipment Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Product Options & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

page 1

Page 4: For vended and commercial homestyle laundry equipment ...

Speed Queen's CardMateTM model linewith factory-installed smart-card readercontrols offerconvenientcashless oper-ation for yourcustomers,and increasedaccountabilityand profitabil-ity for property managers.

The CardMateTM

models includeunique smart-cardmicro chip technolo-gy. This prepaid cardis used to activatelaundry equipment. To receive a card or to add value, a con-venient card service center is available.

SIMPLIFIED INSTALLATION

CardMateTM washers and dryers can be installed by SpeedQueen route operators quickly andeasily, so you can enjoy the benefits of card-operated equipment in no time.

REMAINING BALANCE DISPLAY

Besides the ease and flexibility of installation, theCardMateTM modelline featuresNetMaster ControlTM

(NMC) that informs customers every-thing they need to know about machinestatus at a glance. Residents can at anytime check their remaining card balancewithout starting the machine. This helpsspeed up machine turnover and increaseprofitability. When used in conjunctionwith the NetMasterTM System you canretrieve information on machine usageto increase efficiencies in managingyour laundry room.

The NetMasterCardMateTM

Model Line

Exceptional Choices From

Speed Queen’s NetMasterTM

model line incorporates numerousoptions and customer conveniencefeatures that make the washing anddrying of laundry loads a breeze. TheNetMaster ControlTM (NMC) has features such as:

Vend Price Display

which informs customersof the amount of moneyrequired to operateequipment, then countsdown price as quartersare inserted.

Touch Pad Control

offers a tremendousrange of options.An LED light with asound annunciatorsignals to the user that their selec-tion has been made. The user thenpushes the green start pad afterinserting the card or proper amountof coins.

Cycle Count Down

visually displays total length ofcycle, then counts down thecycle time on the washer anddryer.

Bright, Easy-to-Read Status Lights

that take customers step-by-stepthrough each phase of the wash ordry cycle.

DROP COIN VALIDATOR

automatically verifies magnetic content, coin sizeand weight, and recordstime, date and total amountcollected into memory forfuture data retrieval.

This system allows route operatorsto quickly and easily program andreprogram machines on-site orremotely through a networked PC.This maximizes business control,on-site security and expeditespromotional activities.

MANAGEMENT CONTROLMicro-WandIIIETM

With the state ofthe art NetMasterSystem™, you canhave one centrallocation monitorvarious laundrylocations throughnetwork usage. The hand-held Micro-Wand IIIE™ with infra-red technologystill allows easy on-site programmingand data retrieval. The possibilities areendless for professional laundry roommanagement.

AUDIT CONTROLNetMasterTM Software for Windows

Speed Queen NetMasterTM laundryequipment records the total number ofcycles, special vend options, plus thetime and date of collections, coin vaultopenings, service door openings, powerfailure and more. It calculates andstores data automatically to keep youinformed of day-to-day laundry roomactivities.

Data can be retrievedwith the Micro-WandIIIETM, or remotelythrough a networkedsystem from any-where in the world!Then by downloading the informationinto the NetMasterTM Software, inputactual collection information by loca-tion to generate detailed, reader-friendlyaccountability reports.

NMC

The NetMasterTM

Model Line

TheNetMasterTM

System

page 2

Page 5: For vended and commercial homestyle laundry equipment ...

Speed Queen offers the most completerange of coin-operated and manually operated laundry products; topload andfrontload washers, single and stack dryers, tumblers and washer-extractors,for the variety of needs in multi-housingdwellings.

With features such aswater and energy efficientdesigns, quality internalcomponents and high security systems, multi-housing owners can depend on SpeedQueen equipment to givethem the advantage on such issues asenergy conservation, equipment breakdowns and vandalism.

These electromechanical machines areequipped with one of the followingactivation options:

• Depositing coins into a coin slide

• Depressing the push-to-start knob

It's your choice. Customize your laundryroom to fit your needs.

Speed Queen's commercial quality andexpertise is present in these non-vendedhomestyle model washers and dryers.

Convenient features such as 3wash/rinse temperatures, 6 dryingcycles, 3 fabric types, and selectablewater fill level gives the user exceptional choices for receiving the best laundering possible.

PUSH TO START

TheElectromechanical Model Line

TheCommercial Homestyle Model Line

LI

BE

R T Y

19

91

IN GOD WE

TRUST

Washer Control Panel

Dryer Control Panel

Speed Queen’s Micro-Display™ Control(MDC) is a streamline version of theNetMaster™ control. It offers the fea-tures most important to the residentswith less programming options. TheMDC has features such as:

Coin Countdown Start

which informscustomers ofthe amount ofmoney requiredto operateequipment, then counts

down price as quarters or card areinserted. Once the machine has started, the control counts downremaining cycle time.

Touch Pad Control

has convenient touch pads for accurateselection of cycles and adedicated push-to-startpad to initiate cycle.

Audible Sound Indicator

and LED lights indicate when achange has been made keeping customers aware of cycle status and coin validation.

Bright, Easy-to-Read Status Lights

that take customers step-by-stepthrough each phase of the wash ordry cycle.

COIN OR CARD-OP OPTIONS

Available with drop coinacceptor for coin, or card-operated models forinterfacing with OEM cardreader systems for cashlessoperation.

MDC

The Micro-DisplayTM

Control Model Line

page 3

Page 6: For vended and commercial homestyle laundry equipment ...

Basics In Establishing A Laundry

WHERE CAN COMMON LAUN-DRY ROOMS BE ESTABLISHED?

Multi-housing residences in eitherlow or high rise apartment com-plexes, residence halls, condo-miniums, military housing, collegeresidence halls, guest services andin-unit apartments.

WHY VENDED EQUIPMENT?

The high cost of operating multi-housing residential facilitiesmakes the common laundry areaparticularly attractive. Dependingupon the arrangement made witha laundry service company—com-monly called a Route Operatorwhich supplies the equipment—the cost of operating a laundrycan be completely offset and can,under certain arrangements withthe Route Operator, return aportion of the income obtainedfrom the laundry equipment to anowner or manager of the housingfacility.

WHO INSTALLS & MAINTAINSTHE EQUIPMENT?

The building management canretain the services of a SpeedQueen Route Operator. In thisarrangement the Route Operatorprovides, installs and maintainsthe equipment in the facility athis/her expense. The RouteOperator will, under certainarrangements, return a percentage of the equipmentincome to management. Lease-purchase arrangementsare sometimes availablethrough the Route Operator.

WHERE TO FIND A SPEEDQUEEN ROUTE OPERATOR?

You can contact a Speed QueenRoute Operator nearest you byusing our website locator atwww.speedqueen.comor by checking the classifiedpages of your telephone directory under "Washers andDryers/Coin-Operated" or call 1-800-345-5649 for informa-tion. Look for the Speed Queenname.

WHAT ABOUT ENERGY CONSUMPTION?

Speed Queen equipment has beendesigned for energy conservation.All Speed Queen frontload wash-ers have qualified for the EnergyStar rating by exceeding theDepartment ofEnergy ModifiedEnergy Factor(MEF) standard.

Our heavy duty commercial wash-ers are available in vertical(toploading) and horizontal axisfrontload models. These washershave special energy settings onsome models which lowers waterconsumption and are equippedwith cold water rinse to reducehot water costs. These washers

are designed with industry-lead-ing high speed extract speeds of710 and 1000 RPMs on toploadand frontload washers. This maxi-mizes moisture removal for fasterdrying and less expense to theproperty.

Speed Queen dryers are efficient in fast drying and low in energyconsumption.

Check with a Speed Queen autho-rized Route Operator to find out ifyour utility consumption is as lowas it can be. They can perform aCost Calculator Analysis for you!

HOW MUCH EQUIPMENT?

In planning and designing a laun-dry facility for multi-housing use,it is important to keep in mindthe characteristics of the peoplewho will occupy the building.

The type of multi-housing build-ing will dictate whether the laun-dry equipment should be concen-trated into one centralized area orsmaller rooms spread throughoutthe property. It is important thatthe room(s) are planned withproper facilities for electric andgas hook-ups, water supply anddrainage, as well as proper make-up air and dryer ventilation.

The following pages present our suggestions for the producttypes and amount of Speed Queenequipment required for sizingmulti-housing properties. Specificsituations demand the expertiseof a qualified Route Operator sothe proper equipment in the prop-er mix is provided for the resi-dents convenience.

page 4

Page 7: For vended and commercial homestyle laundry equipment ...

Laundry Room Layouts

CENTRALIZED LAUNDRY ROOMS

(High-Rise Buildings with apart-ments, condos, coops)

The equipment can be concentratedin a convenient central area locatedin the building. The larger spacerequirement can expand the ser-vices to residents with variablesized washer-extractors with biggerload capacities, expanded vendingconcessions, folding tables, andcomfortable waiting areas similarto on-street coin laundries. Forhigh-rise buildings with a centrallaundry room, one washer anddryer set is recommended forevery 20 living units.

DE-CENTRALIZED LAUNDRY ROOMS

(High-Rise or Low Rise Buildingswith apartments, condos, coops)

For planned communities, de-centralized laundry rooms orsmall laundry areas with matchingwashers and dryers are the mostcommon. Usually these establish-ments are amenity oriented, offer-ing folding tables and vendingmachines for the tenant's conve-nience. One washer and one dryeris recommended for every 8 to 12living units.

ON-FLOOR LAUNDRY ROOMS

(Low Rise or Garden-StyleBuildings)

For garden apartments, matchingwasher and dryer pairs are themost customer convenient layout.One washer and one dryer isrecommended for every 8 to 12apartment units.

page 5

Page 8: For vended and commercial homestyle laundry equipment ...

Suggested Floor PlansLaundry Room Layouts

MILITARY HOUSING

Centralized laundry rooms withcommercial top or frontload wash-ers and matching dryers for militarypersonnel. Non-metered (free start)equipment is usually required bymilitary. One washer and one dryeris recommended for every 20 mil-itary personnel.

COLLEGE RESIDENCE HALLS

Centralized laundry rooms are con-veniently located in residence hallswith top or frontload washers andmatching dryers. For student resi-dence halls one washer and onedryer is recommended for every30 to 40 students.

IN-APARTMENT

For ultimate customer convenience,placement of laundry units is with-in the apartment, with top orfrontload washer and matchingdryer. One washer and one dryer isrecommended per unit.

page 6

Page 9: For vended and commercial homestyle laundry equipment ...

Equipment Sizing Ratios

TYPICAL 400-UNIT HIGH-RISEAPARTMENT BUILDING

ACTIVATION: Smart-Card CONTROL: NetMaster™ Control

with touch padMODEL LINE: CardMateTM

EQUIPMENT: Topload and Frontload Washers and Tumblers

HIGH-RISE BUILDINGS(central laundry room)

NMC

Suggested Floor Plans

PROPERTY TYPE NO. OF LIVING UNITSHigh-Rise Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 to 25 living unitsLow-Rise or Garden Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 to 12 living unitsCoops, Condominiums . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 to 12 living unitsSenior Citizen Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 residentsMilitary Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 military personnelCollege Residence Halls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 to 40 studentsGuest Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 roomsIn-Apartment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 set per unit

is defined as 1 ea. topload or frontload washer paired with 1 ea. dryer pocket,or 1 stacked washer/dryer

If multiple sets are needed use the following examples as your guide:

EXAMPLES of Multiple Sets:2 ea. topload/frontload washers ................with ..................................................1 ea. stacked dryer (= 2 dryer pockets)2 ea. topload/frontload washers ................with ..........................................2 ea. single load dryers (= 2 dryer pockets)2 ea. topload/frontload washers ................with ..............1 ea. tumbler dryer (1 tumbler pocket = 2 dryer pockets)

ONE washer/dryer set is recommended for the following:

ONE SET

page 7

Page 10: For vended and commercial homestyle laundry equipment ...

Suggested Floor Plans

TYPICAL 120-UNIT MULTIPLELEVEL HOUSING FACILITY

ACTIVATION: Coin DropCONTROL: NetMaster™

Control with touch padMODEL LINE: NetMasterTM

EQUIPMENT: Horizon StackedWashers/Dryers

HIGH-RISE CONDOMINIUM(decentralized laundry)

TYPICAL 20-UNIT MULTIPLE BEDROOM

ACTIVATION: Coin SlideCONTROL: Rotary SwitchesMODEL LINE: Electromechanical EQUIPMENT: Topload Washers and

Single Load Dryers

LOW-RISE ORGARDEN BUILDINGS

NMC

LI

BE

R T Y

19

91

IN GOD WE

TRUST

page 8

Page 11: For vended and commercial homestyle laundry equipment ...

Suggested Floor Plans

TYPICAL CENTRAL LAUNDRY ROOM

ACTIVATION: Coin Drop or On-Line Debit Card Reader

CONTROL: NetMaster™ Controlwith touch pad

MODEL LINE: NetMaster™ EQUIPMENT: Horizon Frontload &

Topload Washers* with Stack Dryers

*Front control washers and dryers are ADA Compliant

RESIDENCE HALLS(central laundry room*)

page 9

NMC

NetMasterWash Alert

System Data Flow

Web site call back technology of machineavailability for residence laundry rooms

Page 12: For vended and commercial homestyle laundry equipment ...

Suggested Floor Plans

TYPICAL BARRACK FACILITY

ACTIVATION: Push/Pull Start KnobCONTROL: RotaryMODEL LINE: Commercial/HomestyleEQUIPMENT: Topload Washers and

Single Load Dryers

MILITARY HOUSING(central laundry room-BEQ’s or BOQ’s)

TYPICAL GUEST SERVICE FOR VENDED LAUNDRY-HOTEL/MOTEL

ACTIVATION: Coin SlideCONTROL: Rotary MODEL LINE: Electromechanical EQUIPMENT: Topload Washers and

Single Load Dryers

GUEST SERVICES(Hotels, motels, camp-grounds, marinas, truck stops

LI

BE

R T Y

19

91

IN GOD WE

TRUST

page 10

Page 13: For vended and commercial homestyle laundry equipment ...

Suggested Floor Plans

TYPICAL IN-APARTMENTSIDE BY SIDE LAUNDRY FACILITY

ACTIVATION: Push/Pull Start KnobCONTROL: RotaryMODEL LINE: Commercial/HomestyleEQUIPMENT: Top or Frontload

Washer and Single Load Dryer

IN-UNIT APARTMENT/CONDOWASHER AND DRYER

page 11

ADA Compliance(American Disabilities Act)

Speed Queen’s Front Control & Front Loading Laundry Equipment Makes the GradeYour students have enough on their minds without having to think about how to do their laundry.

Speed Queen’s Horizon front control and front loading side-by-sidewasher and dryer models are designed for front access so allcontrols and mechanisms, including doors, lint screens, detergentand bleach compartments comply with ANSI/CABO A117.1-98reach standards for unobstructed front and side access.

ADA unobstructed front or side reach requirements:Control Panel 48” Max HeightLoading Door (from floor) 15” Min. Height

Speed Queen Horizon Washer and Dryer measure up to ADA:Control Panel 40” HeightLoading Door (from floor) 15.5” Height

If you are concerned about your laundry room complying with ADA regulations, stop worrying. Purchase Speed Queen’s Horizon washer and dryer to meet the needs of ADA, but most importantly the needs of your students or residents.

Page 14: For vended and commercial homestyle laundry equipment ...

Installation Suggestions & Equipment Specifications

1. Determine the size of thelaundry room by allowing a mini-mum of 25 square feet (2.25 m2)per machine.

2. At least one floor drain shouldbe provided in each laundry.

3. Wash tubs not required.However, if they are installed,provide adequate space for them.Such space shall be in addition to that recommended for eachmachine.

4. Locate dryers on outside wallssince long ducts increase installa-tion cost and are less effective forproper venting.

5. For proper operation, it isimportant to locate the dryer in anarea that has an ample amount ofmake-up air to replace the amountexhausted by the dryer. Energy efficient multi-housing facilitieswith low air infiltration ratesshould be equipped with an airexchanger that can accommodateon-demand make-up air. Thesedevices can be obtained throughyour building contractor or buildingmaterial suppliers.

6. Tumbler make-up air must bebrought into the room to replaceair being exhausted. Tumblersrequire fresh outside make-up air.

Minimum requirement:Single Tumblers - 144 sq. in. opening to the outside.

Stack Tumblers - 288 sq. in. opening to the outside.

7. Provide sufficient lighting,preferably fluorescent.

GENERAL ROOM INFORMATION

One dryer for each single load(topload or frontload) washer is the recommended product balance.One stacked dryer, or one 25-lb.RouteMasterTM tumbler will accommodate two topload orfrontload washers. A stacked tum-bler will accommodate for 4topload washers.

EQUIPMENT SIZING RECOMMENDATION

Water Usage Charts for Topload andFrontload Washers

Topload and Frontload Washers

Electrical Requirements

1. Each washer is designed to beoperated on an individual three-wire grounded, 120 volt, 60 Hzelectrical circuit protected by a 15or 20 amp fuse, equivalent fusetronor circuit breaker. No. 12 wire recommended for electrical connection or as required by localcodes.

2. All receptacles shall be equippedfor a three prong grounded plug.

Plumbing Requirements

1. Water supply faucets must fitstandard 3/4" (19.1 mm) femalehose couplings.

2. Hot water facilities should havethe capability of maintaining aconstant water temperature ofbetween 120º-140ºF for frontloadwashers and 140º-150ºF for toploadwashers.

3. Maintain cold water tempera-ture at not less than 35ºF (1.6ºC).

4. Washer will operate under avariety of sufficient water pressureconditions; however, a constantwater pressure of 30 psi must bemaintained.

5. Drain each washer into a minimum 2" (50.8 mm) diameterby 3' tall cast iron, PVC or copperstandpipe.

page 12

Water Usage Chart - Topload MDC - Water Saver

Total WaterCycle /Temp. Hot Cold Consumption

Normal/Hot 15.5 10.0 25.5 Gallons

Normal/Warm 6.9 18.6 25.5 Gallons

Perm. Press/Warm 6.9 18.6 25.5 Gallons

Delicate/Cold 0.0 25.5 25.5 Gallons

DOE clothes washer test standards appendix “J1” for a 10.9 lb load.

Water Usage Chart - Horizon MDC

Total WaterCycle /Temp. Hot Cold Consumption

Normal/Hot 7.0 12.2 19.2 Gallons

Normal/Warm 2.7 16.5 19.2 Gallons

Perm. Press/Warm 2.7 16.5 19.2 Gallons

Delicate/Cold 0.0 19.2 19.2 Gallons

DOE clothes washer test standards appendix “J1” for a 11.7 lb load.

Page 15: For vended and commercial homestyle laundry equipment ...

Installation Suggestions& Equipment Specifications

Electrical Requirements

1. (Electric Models) Provide separate circuits from the mainpanel to each dryer. Each dryerhas its own terminal block thatmust be connected to a separatebranch three-wire, 120/240 or120/208 volt, 60 Hz, single phasecircuit using at least No. 10 copperwire and fused at 30 amps; agrounded neutral wire must beprovided. Do not connect dryers to110, 115 or 120 volt circuits.

2. (Electric Models) If branch circuit to electric dryers is 15 ft.(4572 mm) or less in length, use UL approved No. 10 copper wire, or as required by local codes. Ifover 15 ft. (4572 mm), use No. 8 UL approved copper wire, or asrequired by local codes.

3. (Gas Models) Each gas dryer is designed to be operated on an individual three-wire grounded 120 volt, 60 Hz. electrical circuit protected by a 15 amp fuse, equiv-alent fusetron or circuit breaker.(See specifications)

4. (Gas Models) Plug each dryer'spower cord into a grounded 3-slotwall receptacle on a separate

Single and Stack Dryers(Gas and Electric models)

circuit. Do not operate other appliances on the same circuitwhen dryer is operating.

5. (Electric and Gas Models) Alldryer installations should conformto the latest edition of the NationalElectrical Code, NFPA 70, and suchlocal requirements as might apply.

Gas Requirements(also see Figure 1 below)

1. The gas dryer installation mustconform with the latest edition ofAmerican National Standard Z223.1(NFPA 54) National Fuel Gas Code.

2. Size of main gas supply unitwill depend on number of dryerunits connected. Consult localgas utility.

3. Where bottled gas (L.P.) is used, follow the specifications ofthe local gas company. A special conversion kit for L.P. is required.Consult your Speed Queen RouteOperator for details.

Venting Requirements for Singleand Multi-Dryer Installations

1. The gas dryer installation shouldcomply with the latest edition ofthe National Fuel Gas Code, Z223.1(NFPA 54).

2. A 4" (102 mm) vent hood with adamper (for each dryer) should beplaced in the wall behind the dryer while the building is underconstruction.

3. Exhaust pipe must be 4" (102 mm) in diameter having noobstructions. Rigid or flexible metal pipe must be used.

D233IE2E

3/8" NPTGAS CONNECTION

1/8" NPTPIPE PLUG

(For checkinginlet gas pressure)

NEW STAINLESS

STEELFLEXIBLE

CONNECTOR USE ONLY

IF ALLOWED BY LOCAL

CODES (Use

Design A.G.A.Certified

Connector)

EQUIPMENTSHUT-OFF

VALVEInstalled within

6' (1.8 m) of dryer BLACK IRON PIPEShorter than 20' (6.1 m) - use 3/8" pipeLonger than 20' (6.1 m) - use 1/2" pipe

D673I

Weather Hood TypeRecommended

Number of90º Elbows

Maximum lengthof 4" (102 mm) diameter rigid

metal duct

Weather Hood TypeUse only for short run installs

Number of90º Elbows

Maximum lengthof 4" (102 mm) diameter rigid

metal duct

D011IE2E

2-1/2"(6.35 cm)

Figure 1

page 13

0 65 ft (19.8 m)1 55 ft (16.8 m)2 47 ft (14.3 m)3 36 ft (11.0 m)4 28 ft (8.5 m)

0 45 ft (13.7 m)1 35 ft (10.7 m)2 30 ft (9.1 m)3 25 ft (7.6 m)4 20 ft (6.1 m)

0 55 ft (16.8 m)1 47 ft (14.3 m)2 41 ft (12.5 m)3 30 ft (9.1 m)4 22 ft (6.7 m)0 35 ft (10.7 m)1 27 ft (8.2 m)2 21 ft (6.4 m)3 17 ft (5.2 m)4 15 ft (4.5 m)

4”(10.2 cm)

4”(10.2 cm)

Page 16: For vended and commercial homestyle laundry equipment ...

Installation Suggestions& Equipment Specifications

Electric Dryerand StackedDryer

Canada

Gas Dryer andStacked Dryer

Canada

60 Hz. 5350 wattelement, 120/240V or 4750 watt element,120/208V, 3-wire, 1 phase, 30 amp.

60Hz. 5,000 watt element, 120/240 or 120/208V, 4-wire,1 phase, 30 amp ondryer; 60 amp onstacked dryer.

60 Hz. AC, 120V,grounded 3-wire, 1 phase, 15 amp.

60 Hz. AC, 120V,grounded 3-wire,1 phase 15 amp ondryer; 30 amp onstacked dryer.

Electrical Requirements

Duct Station Minimum Diameterof Collector Duct

A 4 inches (102 mm)

B 8 inches (203 mm)

C 9 inches (229 mm)

D 10 inches (254 mm)

E 11 inches (279 mm)

F 12 inches (305 mm)

G 13 inches (330 mm)

H 14 inches (356 mm)

I 15 inches (381 mm)

J 15 inches (381 mm)

K 16 inches (406 mm)

NOTE: Main collector ducts should be equipped withan auxiliary fan that can maintain the duct airflow ata minimum of 1200 ft (366 m) per min. If you do nothave a fan, clean the main collector duct at leasttwice a year.

DO NOT use flexible plastic orthin foil ducting as it will greatlyreduce the dryer's performance.Outer end of exhaust pipe musthave weather hood installed atleast 12" (305 mm) above ground.Always keep exhaust duct as shortas possible.

4. Gas dryers can be vented fromthe right side, back, or bottom(except upper unit of stack dryer).Dryer can be installed flush to thewall at side and back. Electric dry-ers can be routed from left side aswell.

5. The exhaust duct should not bebuilt into the wall. If laundries aredistributed in multi-story buildings,the duct size at the first floorshould be at least 4" (102 mm) andshould be increased in size 1" (25.4mm) per floor to a maximum of 12"(305 mm). For the installation ofseveral dryers where a main collec-tor duct is used, see illustration forproper angle of air flow. Dryerexhaust duct should enter mainduct at an angle of no more than30º pointing in the direction of theairflow. Ducts entering the mainduct from opposite sides should bestaggered so as not to oppose eachother. Provisions should be madefor periodic lint removal and clean-ing of the main collector duct.

6. If several dryers are exhaustedinto a main collector duct, it isessential that ductwork be adequate in size and properly constructed for efficient operation.Provisions for make-up air must beprovided. Each dryer exhaustsapproximately 220 cubic feet*(6.1 m3) of air per minute. * Measured at point of exit from the dryer.

7. The main collector duct shouldbe sized according to specifications

presented in the chart on the right.The outside of the main ductshould have a weather hood (withhinged damper) installed to preventpassage of weather elements,insects, dust and dirt into the dryer.

8. Each dryer should have a backdraft damper kit, part number58786.

D686I

A B C D E F G H I J K

30°

5

12

3

4

24" (61cm)MINIMUM

CLEARANCE TOROOF/GROUND

EXHAUST AIR FLOWMAXIMUM LENGTH OF DUCT

30 feet (9.1)

AIRFLOW

EXHAUSTOUTLET

HORIZONTAL EXHAUST INSTALLATION

1 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes.2 Wall

3 2" (5 cm) Minimum or Clearance per local codes4 No Screen or Cap2 Clean Out Cover - Inspect Monthly

page 14

D753I

24" (61cm)MINIMUM

CLEARANCE TOROOF/GROUND

CONNECT TO DRYER

2

1

5

3

4

VERTICAL EXHAUST INSTALLATION

1 Roof2 No Screen or Cap 3 Wall4 2" (5 cm) Minimum5 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes.

Page 17: For vended and commercial homestyle laundry equipment ...

Installation Suggestions & Equipment Specifications

Electrical Requirements

1. Provide separate circuits fromthe main panel to each tumbler.The 120 volt, 60 hertz, single phaseunits require an individual three-wire, grounded, 120 volt, 60 Hzelectrical circuit protected by a 15amp fusetron or circuit breaker.The 208 volt or 240 volt, 60 Hz,single phase units require a three-wire plus ground circuit (two hotleads, a neutral and a ground).Each circuit must be protected witha two-pole, 10 amp circuit breaker.

2. All tumbler units must begrounded in accordance with thelatest edition of the NationalElectrical Code, NFPA 70, and localcodes and ordinances.

Gas Requirements

1. Install a 1-1/2" (38.1 mm) maingas line for the laundry room for upto 10 tumblers.

2. Install a 1/2" (12.7 mm) gasline on the wall for connection tothe back of the dryer. Terminate itwith a 1/2" (12.7 mm) T, 6" (152.4mm) drip leg and 1/2" (12.7 mm)gas cock.

Venting Requirements

1. Locate where least exhaust piping and elbows will be required.Use sweep elbows. The exhaustshould be directed upward.

2. All duct workmust be adequate insize. See ductingchart below.

3. Provide cleanoutand inspection doorsin duct. All electricaland plumbinginstallations mustconform to local andnational codes.

25 lb. and 30 lb.Single Tumbler

Canada

Export Models

Stacked Tumbler

Canada

Export Models

60 Hz. 120V, 1 phase12.0 amps, 2-wiregrounded circuit (L1,N, G). Requires 15amp one-poleprotection.

60 Hz. 208-240V, 1phase 6.7 amps, 3-wire grounded circuit(L1, N, L2, G).Requires 10 amptwo-pole protection.

Same as above

50 Hz. 240V, 1 phase,24.0 amps, 2-wiregrounded circuit (L1,L2, G). Requires 10amp two-pole- protection.

60 Hz. 120V, 1 phase,24.0 amps, 2-wiregrounded circuit (L1,N, G). Requires 30amp one-poleprotection.60 Hz. 208-240V, 1 phase, 13.4 amps,3-wire grounded cir-cuit (L1, N, L2, G).Requires 20 amptwo-pole protection.

Same as above

50 Hz. 240V, 1 phase,15 amps, 2-wiregrounded circuit (L1,L2, G). Requires 20amp two-poleprotection.60 Hz. 220V, 1 phase,11.6 amps, 2-wire(plus ground) (L1, N,G). Requires 15 amptwo-pole protection.

25 lb., 30 lb. & 35 lb.Single Tumbler 30 lb. Stacked Tumbler

Use sweep elbows. The exhaustshould be directed upward.

2. All duct work must be adequatein size. See ducting chart below.

3. Provide cleanout and inspectiondoors in duct. All electrical andplumbing installations must con-form to local and national codes.

Electrical Requirements

Electrical Requirements

1. Provide separate circuits fromthe main panel to each tumbler.There is only ONE electrical connection to the stacked tumblerupper pocket junction box. The 120 volt, 60 hertz, single phaseunits require an individual three-wire, grounded, 120 volt, electricalcircuit protected by a 30 ampfusetron or circuit breaker. The 208 volt or 240 volt, 60 hertz, single phase units require a three-wire plus ground circuit (two hotleads, a neutral and a ground). Eachcircuit must be protected with atwo pole, 20 amp circuit breaker.

2. All stacked tumbler units mustbe grounded in accordance withthe latest edition of the NationalElectrical Code, NFPA 70, and localcodes and ordinances.

Gas Requirements

1. Install a 1-1/2" (38.1 mm) maingas line for the laundry room for upto 10 tumblers.

2. Install a 3/4" (19.05 mm) gasline on the wall for connection tothe back of the dryer. Terminate itwith a 3/4" (19.05 mm) T, 6" (152.4mm) drip leg and 3/4" (12.7 mm)gas cock.

Venting Requirements

1. Locate where least exhaust piping and elbows will be required.

WALL

AIR OUT

CLEARANCEPER LOCAL

CODES

NO SCREENOR CAP

NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALLOR CEILING. THE OPENING MUST BE SIZED PER LOCAL CODES.

MINIMUM DIAMETER FOR MODELS 0300D, 0350S

9"12"15"17"19"21"23"25"26"27"29"30"

MINIMUM DIAMETER FOR MODELS 0220S, 0270S

7"9"11"13"15"16"18"19"20"21"23"23"

45°

INSPECTION ORCLEANOUT COVER

page 15

Page 18: For vended and commercial homestyle laundry equipment ...

Product Options & Dimensions

Electric dryer can beexhausted in anydirection, vented outrear, either side or base.Gas models have 3-way venting: right side, backand base.

Gas dryers available fornatural gas, L.P. gas kitavailable. L.P. GasConversion Kit mustbe installed by theManufacturer's Authorized Dealers, Distributors, or local service personnel.Power cord is furnished (120/60/1).

Electric dryer models do not have power cord furnished (120/240/60/1 or 120/208/60/1).

NMC

D611I

28" (71.1 cm)

23.5" (59.7 cm)

26.9" (88.3 cm)

15.4" (39.1 cm)

4.5" (11.4 cm)

8.0" (20.3 cm)

4.0" (10.2 cm)

.4" (1.02 cm)

43"

(109

.2 c

m)

36"

(91.

4 cm

)

Washer has 3/4" (1.87cm) connection forwater mixing valve.Two water inlet hosessupplied with washer.

Drain hose is 5' (150 cm)long. One inch (2.5 cm)inside diameter.

Power cord has three-prong U.L. approvedplug for connection to agrounded three-wire, 120 volt, 60 Hz electrical circuit. 15 to 20 amp. Use at leastNo. 12 wire, heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be 36” high.

C

H

W553I

51"

(129

.54

cm)

44.7

5" (

1136

.7 c

m)

26" (66.04 cm)0.44"

(11.11 cm)28" (71.12 cm)

35.8

8" (

91.0

5 cm

)

43"

(109

.22

cm)

28.7

5" (

73.0

2 cm

)

25.63" (65.09 cm)

30.5

" (7

4.47

cm

)

Topl

oad

Was

her

Smal

l Dry

er

page 16

MDC PUSH TO START

NMC MDC PUSH TO START

Washer has 3/4" (1.87cm) connection forwater mixing valve.Two water inlet hosessupplied with washer.

Drain hose is 4' (122 cm)long. One inch (2.5 cm)inside diameter.

Power cord has three-prong U.L. approvedplug for connection to agrounded three-wire, 120 volt, 60 Hz electrical circuit. 15 to 20 amp. Use at leastNo. 12 wire, heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be 36” high.

H270I

29.6

" (7

5.1

cm)

31.1

" (7

9 cm

)

43"

(109

.2 c

m)

26.9" (68.3 cm)28"

(71.1 cm)

14.9" (37.9 cm)

17.5" (44.8 cm)

2" (5.1 cm)

Hor

izon

Fro

ntlo

ad W

ashe

r

NMC MDC

WWaasshheerr ss && DDrryyee rr ss

Page 19: For vended and commercial homestyle laundry equipment ...

Electric dryer can beexhausted in anydirection, vented outrear, either side or base.Gas models have 3-way venting: right side, backand base.

Gas dryers available fornatural gas, L.P. gas kitavailable. L.P. GasConversion Kit mustbe installed by theManufacturer's Authorized Dealers, Distributors, or local service personnel. Power cord isfurnished (120/60/1).

Electric dryer does not have power cord furnished 120/240/60/1, (may be converted to120/208/60/1).

D825I

43.0

" (1

09.2

cm

)

28" (71.1 cm)

23.5" (59.7 cm)

8.0" (20.3 cm)

0.4" (1.0 cm) 26.9"

(68.3 cm)

4.5" (11.4 cm)

4.0" (10.2 cm)

2" (5.1 cm)

15.4" (39.1 cm)

Washer has 3/4" (1.87cm) connection forwater mixing valve.Two water inlet hosessupplied with washer.

Drain hose is 4' (122 cm)long. One inch (2.5 cm)inside diameter.

Power cord has three-prong U.L. approvedplug for connection to agrounded three-wire, 120 volt, 60 Hz electrical circuit. 15 to 20 amp. Use at leastNo. 12 wire, heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be 36” high.

H269I

28" (71.1 cm)

29.6

" (7

5.1

cm)

31.1

" (7

9 cm

)

43"

(109

.2 c

m)

26.9" (68.3 cm)

14.3" (36.3 cm)

17.5" (44.8 cm)

2" (5.1 cm)

2" (5.1 cm)

Product Options & Dimensions

Hor

izon

Fro

ntlo

ad W

ashe

rH

oriz

on F

ront

load

Dry

er

Gas Supply Connection:3/8" (.937 cm) pipeprovided at rear.Stacked dryer is deliveredcomplete as one unit.Factory equippedfor natural gasoperation only. L.P. kitsavailable.

L.P. Gas Conversion Kitmust be installed by theManufacturer'sAuthorized Dealers,Distributors, or local service personnel.

Solid door or door with window available.

D786I

*44.

8" (

113.

6 cm

)

*76.

5" (

194.

3 cm

)

26.9" (68.3 cm)

28" (71.1 cm)

23.5" (59.7 cm)

15.5" (39.4 cm)4"

(10.2 cm)

7" (17.8 cm)

4.5" (11.4 cm)

8" (20.3 cm)

NOTE: Not all models have windows.

ELECTRIC MODELS

*With leveling legs turned into base.

Stac

ked

Drye

r

NMC MDC

NMC MDC

NMC MDC

WWaasshheerr ss && DDrryyee rr ss page 17

PUSH TO START

Page 20: For vended and commercial homestyle laundry equipment ...

Washer has 3/4" (1.87 cm) con-nection for water mixing valve.Two water inlet hoses suppliedwith washer.

Drain hose is 5' (150 cm) long.One inch (2.5 cm) inside diame-ter.

Power cord has three-prong U.L.approved plug for connection toa grounded three-wire, 120 volt,60 Hz electrical circuit. 15 to 20amp. Use at least No. 12 wire,heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be as high as the washer top.

W507IE1A

28" (71.1 cm)

53"

(134

.6 c

m)

26" (66.0 cm)

29"

(73.

7 cm

)

43"

(109

.2 c

m)

36.4

" (9

2.5

cm)

25.6" (65.0 cm).4"

(10.2 mm)

Com

mer

cial

/Hom

esty

leW

ashe

r

Product Options & Dimensionspage 18 WWaasshheerr ss && DDrryyee rr ss

Hor

izon

Sta

cked

Was

her/

Drye

r

Gas Supply Connection:3/8" (.937 cm) pipeprovided at rear.Stacked washer/dryer isdelivered complete asone unit. Factoryequipped for naturalgas operation only. L.P.kits available.

L.P. Gas Conversion Kitmust be installed bythe Manufacturer'sAuthorized Dealers,Distributors, or localservice personnel.

SWD440N

75"

(190

.5 c

m)

44.1

" (1

12 c

m)

29.6

" (7

5.1

cm)

31.1

" (7

9 cm

)

28" (71.1 cm)

14.3" (36.3 cm)

8.0" (20.3 cm)

5.25" (13.3 cm)

17.5" (44.8 cm)

23.5" (59.7 cm)

2" (5.1 cm)

26.9" (68.3 cm)

15.4" (39.1 cm)

ELECTRIC DRYERS

*With leveling legs turned into the base.

Electric dryer canbe exhausted inany direction,vented out rear,either side or base.Gas models have3-way venting: right side,back and base.

Gas dryers avail-able for naturalgas, L.P. gas kitavailable. L.P. GasConversion Kit must be installed by the Manufacturer's Authorized Dealers, Distributors,or local service personnel. Power cord is furnished (120/60/1).

Electric dryer does not have power cord furnished (120/240/60/1).

D616I

36"

(91.

4 cm

)

28" (71.1 cm)

ELECTRIC DRYERS

*With leveling legs turned into the base.

*43"

(10

9.2

cm)

23.5" (59.7 cm)

0.4" (1.1 cm)

26.9" (68.3 cm)

4" (10.2 cm)

15.4" (39.1 cm)

4.5" (11.4 cm)

8.0" (20.3 cm)

Com

mer

cial

/Hom

esty

le

Drye

r

NMC MDC

Page 21: For vended and commercial homestyle laundry equipment ...

Washer has 3/4" (1.87 cm) con-nection for water mixing valve.Two water inlet hoses suppliedwith washer.

Drain hose is 4' (122 cm) long.One inch (2.5 cm) inside diameter.

Power cord has three-prong U.L.approved plug for connection toa grounded three-wire, 120 volt,60 Hz electrical circuit. 15 to 20amp. Use at least No. 12 wire,heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be 36” high.

Washer has 3/4" (1.87 cm)connection for water mixingvalve. Two water inlet hosessupplied with washer.

Drain hose is 4' (122 cm)long. One inch (2.5 cm)inside diameter.

Power cord has three-prongU.L. approved plug for con-nection to a grounded three-wire, 120 volt, 60 Hz electri-cal circuit. 15 to 20 amp. Useat least No. 12 wire, heavier for long distances.

Dimensions are with leveling legs. Stand pipe should be 36” high.

H327I

43"

(109

.2 c

m)

26.9" (68.3 cm)

28" (71.1 cm)

14.9" (37.9 cm)

17.5" (44.8 cm)

2" (5.1 cm)

36.6

" (9

3 cm

)

31.1

" (7

9 cm

)29

.6"

(75.

1 cm

)

Com

mer

cial

/Hom

esty

le

Rear

con

trol

Fro

ntlo

ad W

ashe

r

Product Options & Dimensions

FLW701N

26.9" (68.3 cm)

31.1

" (7

9 cm

)

29.6

" (7

5.1

cm)

41.2

" (1

04.6

cm

)

28" (71.1 cm)

14.9" (37.9 cm)

17.5" (44.8 cm)

2" (5.1 cm)

HHoommeess ttyy llee WWaasshheerr ss && DDrryyee rr ss

Com

mer

cial

/Hom

esty

le

Fron

t co

ntro

l Fro

ntlo

ad W

ashe

r

page 19

Electric dryer can be exhaustedin any direction, vented outrear, either side or base. Gasmodels have 3-way venting:right side, back and base.

Gas dryers available for naturalgas, L.P. gas kit available. L.P.Gas Conversion Kit must beinstalled by the Manufacturer'sAuthorized Dealers, Distributors,or local service personnel.Power cord is furnished(120/60/1).

Electric dryer does not have power cord furnished (120/240/60/1).

Com

mer

cial

/Hom

esty

le

Fron

t Co

ntro

l Dry

er

DRY684N

28" (71.1 cm)

ELECTRIC DRYERS

*With leveling legs turned into the base.

*41.

2" (

104.

6 cm

)

26.9" (68.3 cm)

23.5" (59.7 cm)

8.0" (20.3 cm)

4.5" (11.4 cm)

15.4" (39.1 cm)

4.0" (10.2 cm)

0.4" (1.1 cm)

Page 22: For vended and commercial homestyle laundry equipment ...

Product Options & Dimensionspage 20 TTuummbbllee rr ss

63.8

75"

(162

2 m

m)

28"(711 mm)

27.5

" (6

99 c

m)

26.25" (667 mm)

38.875"(987 mm)

27.5

" (6

99 m

m)

35# 28" (711 mm)30# 26.25" (667 mm)

35# 31.5" (800 mm)30# 28" (711 mm)

44.875"(1140 mm)

63.8

75"

(162

2 m

m)

Handles 25 lb. (11kg) loads

Energy saving gas modelsat 64,000 BTU/hr (18.8 kW)

Electric and Steam modelsalso available.

Handles 30 lb. (13.6 kg)or 35 lb. (15.9) loads

Energy saving gas modelsat 73,000 BTU/hr (21.4 kW)

Electric and Steam modelsalso available.

Two full size 30 lb.(13.6 kg) pocketshandle wash loadseasily.

Energy saving gasmodels at 73,000BTU/hr (21.4 kW),per cylinder.

Electric and Steammodels also available.

76.2

5" (

1937

mm

)

42.875"(1040 mm)

31.5"(800 mm)

10"(254 mm)

28"(711 mm)

25 lb

. Rou

teM

aste

rTM30

/35

lb. S

ingl

e Tu

mbl

er30

lb. S

tack

ed T

umbl

er

NMC MDC

NMC MDC

NMC MDC

Page 23: For vended and commercial homestyle laundry equipment ...
Page 24: For vended and commercial homestyle laundry equipment ...

The Right Choice For You

800 � 345 � 5649 www.speedqueen.comAM02-103