+ All Categories
Home > Documents > Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Date post: 08-Jan-2018
Category:
Upload: gervase-doyle
View: 248 times
Download: 0 times
Share this document with a friend
Description:
Forward Capstan Check hydraulic fluid in APU (VSP room). Run APU for 5 minutes. On deck operate forward and reverse. Lubricate lever as needed. Hydraulic fluid gauge Forward & reverse lever
8
Forward & Aft Searchlight Operate Forward & Aft Searchlight.
Transcript
Page 1: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Forward & Aft Searchlight

Operate Forward & Aft Searchlight.

Page 2: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Searchlight Operating Procedures

4

5

6

1

2

7

31. OFF – START SWITCH. HOLD IN START JUST

LONG ENOUGH TO LIGHT BEAM. SWITCH RETURNS TO CENTER WHEN RELEASED. MOVE TO OFF TO TURN OFF BEAM.

2. SPEED CONTROL SWITCH. ROTATE KNOB CLOCKWISE TO INCREASE SPEED OF BEAM MOVEMENT.

3. UP-DOWN-LEFT-RIGHT SWITCH. MOVE HANDLE IN DIRECTION TO PRODUCE DESIRED BEAM MOVEMENT.

4. BEAM FOCOUS SWITCH. MOVE SWITCH EITHER WAY UNTIL DESIRED BEAM SHAPE IS ATTAINED.

5. TEST SWITCH. PUSH WHEN BEAM IS ON TO MAKE SURE THAT OVER TEMP INDICATOR LAMP WORKS.

6. OVER TEMP LIGHT. INDICATES POSSIBLE TROUBLE WHEN LIT. IT IS TURNED ON BY THERMOSWITCH IN SEARCHLIGHT, WARNING THAT LAMP IS TOO HOT, AIR FLOW SWITCH IN POWER SUPPLY INDICATING THAT FAN IS NOT MOVING SUFFICIENT AIR, OR OVERLOAD RELAY IN POWER SUPPLY INDICATING IT IS DRAWING TOO MUCH CURRENT. USE SEARCHLIGHT AS LITTLE AS POSSIBLE UNTIL SOURCE OF TROUBLE HAS BEEN CORRECTED.

7. CONTROL ONLY SWITCH. HOLD SWITCH DEPRESSED TO MOVE SEARCHLIGHT (WITH UP-DOWN-LEFT-RIGHT SWITCH) WITH BEAM OFF.

Page 3: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Forward Capstan• Check hydraulic

fluid in APU (VSP room).

• Run APU for 5 minutes.

• On deck operate forward and reverse.

• Lubricate lever as needed.

Hydraulic fluid gauge

Forward & reverse lever

Page 4: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Aft Capstan

• Check hydraulic fluid in APU (Foam room).

• Run APU for 5 minutes.

• On deck operate forward and reverse.

• Lubricate lever as needed.

Hydraulic fluid gauge

Forward & reverse lever

Page 5: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Rescue Platform

• Check hydraulic fluid in APU (Engine room).

• Run APU for 5 minutes.

• On deck – operate platform.

Hydraulic fluid gauge

Operational levers

Page 6: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Crane Hydraulic Unit

• Check Hydraulic Fluid in APU.

• Run APU for 5 minutes.

• Operate Crane.

Page 7: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Crane

Operate Crane

Page 8: Forward & Aft Searchlight Operate Forward & Aft Searchlight.

Crane - weekly checks -

Check hydraulic oil level in APU.

Cylinder holding valves for proper operation. Operate Boom up and Telescope Out functions with hydraulic system off. Boom(s) should not move.

Winch brake for proper operation at rated winch capacity.

Presence and proper operation of load hook safety latch.

Proper operation of all safety devices.

Check boom angle indicator for operation.

Check all electrical connections to/from crane for wear or damage.

Check for fatigue cracks in hook and shank.

Fatigue cracks in hook and shank

Insure wire suction valve is open at each start-up.

Boom angle indicator


Recommended