Frac Support ServicesFrac support from start to finish
Wherever your frac project takes place, the need for unwavering equipment reliability remains the same. Thats why Cameron adopts a holistic view of your frac operation, offering
a total portfolio of frac equipment and services.
We are committed to helping you apply the most
appropriate and effective frac treatment with
minimal downtime through our fleet of innovative
frac trees, manifolds, valves and flowback equipment.
our services include:
Frac tree and manifold installation and testing
annulus and casing testing
Valve greasing and maintenance
Hydraulic lubricator testing
Installation of backpressure valves, tree test plugs
and Vr plugs
Flowback and well testing
We also believe in giving you options that can have
a positive impact on your CaPeX and oPeX costs.
our fleet of quality rental equipment can offer an
economical, temporary solution for fast turnaround
situations and greatly helps to reduce well
installation costs.
Frac-Support Rental Equipment
Frac trees
Frac manifolds
Frac gate valves
Hydraulic actuators
Torque and test trailers
Frac Isolation Systems
Goat/frac heads
Flowback and Well-Testing Rental Equipment
Plug catchers
Sand separators
Gate valve choke and plug valve manifolds
emergency shutdown valves (eSD)
Well test separators
Hydraulic choke control trailers
mobile flare units
at Cameron, aftermarket service is paramount.
We are prepared to maintain your frac equipment
from the time of installation until it is disassembled
and removed from the project site. To support this
commitment, Cameron has invested in the expansion
of frac-support remanufacturing facilities located in
Grande Prairie, Canada; new Iberia, La; minot, nD; and
Corpus Christi and Pearsall, TX.
Table of Contents
Frac Support from Start to Finish ...................1
Frac Support Services ......................................2
Field Services Fleet ..........................................4
Frac Valves........................................................5
Frac Trees .........................................................6
Frac manifolds .................................................8
monoline Frac Fluid Delivery Systems ............9
FracServ Valve Integrity Protection Plan ...10
Frac Facts ........................................................11
Flowback and Well Testing ...........................12
Plug Valve Choke manifolds ......................13
Plug Catchers ..............................................13
Sand Separators .........................................13
Hydraulic-actuated Gate Valve
Choke manifolds ........................................14
Well Test Separators ..................................14
emergency Shutdown Valves (eSD) ..........14
Hydraulic Choke Control Trailers ...............15
Flare Systems ..............................................15
1
Cameron is reinventing efficiency in frac equipment, constantly evolving tree designs to fit operators needs.
FraC SUPPorT SerVICeS
Camerons frac equipment is backed by CamSerV,
Camerons aftermarket services. Camerons service
technicians provide total aftermarket support in the
field or in the shop 24 hours a day, 365 days a year.
Personnel are highly skilled in providing equipment
installation and testing, making field repairs and
performing maintenance on your equipment.
Cameron is committed to drive efficiencies throughout
your operation by assigning cross-trained personnel
to work on your project location, and by following a
set of defined procedures. The more people present
on your project location the higher the potential is
for HSe issues, unnecessary expenses and logistical
problems. We cross-train personnel to handle both
frac and flowback operations, which allows for a
reduction in required crew members and all costs, nPT
and emissions associated with multiple cranes, testing
units, grease units, and equipment support.
Wellsite Services
Wellhead rental and sales
Frac tree rental and sales
Installation and testing
annulus and casing testing
Valve greasing and maintenance
repair, refurbishment and maintenance of all major
frac and wellhead equipment
Installation of BPVs, tree test plugs and Vr plugs
Field inspection and general conditioning
Camerons robust frac support services include asset
tracking, journey management and competency
management.
Asset Management
our asset management system gives you increased
system uptime through integrated support. It is a
comprehensive maintenance and asset management
system specifically designed for equipment and
performance monitoring throughout the life of your
assets. Camerons asset management system offers
you the ability to manage assets and track spare parts,
contracts, clients, locations, service tickets and more.
radio frequency identification (rFID) tagging is at
the core of our asset management initiative. rFID
is used to track Camerons assets, increasing data
integrity and providing accurate asset utilization
information and equipment maintenance history.
This system eliminates the need to locate equipment
serial and parts numbers using hazardous chemicals,
and it reduces the risk of personnel being exposed to
potentially dangerous conditions.
2
Cameron uses an in-house system to monitor equipment and performance throughout the life of your assets.
Journey Management
Cameron fulfills client journey management
requirements and strives toward our own goal of
safety excellence. Journey management is required
by every Cameron employee for each service job
conducted. Camerons employees complete a jobsite
review checklist before each job is executed. These
reviews include some of the following tasks: PPe
preparation, review of customer jobsite requirements,
mapping of jobsite location, review and preparation
for weather conditions, and properly outfitting the
work vehicle with tools, supplies and equipment.
GPS devices on our service vehicles allow us to
examine driving behaviors, track use of the vehicles
and estimate travel time to and from field locations,
optimizing operating efficiencies.
Service Competency Management
Cameron utilizes a global network of highly skilled
service technicians to address your needs. our
personnel provide expert installation, testing, repair
and maintenance support for your equipment.
Camerons field service personnel are trained to bring
professionalism, knowledge, skills, safe work practices,
and efficiencies to your project. Having invested in
a 15,000-sq-ft facility and a fully functional shop,
Cameron requires service technicians to attend a
comprehensive basic wellhead field-service training
program and targeted advanced training. This helps
to ensure technicians remain up-to-date on equipment
procedures. In addition, tracking and recording of
their experience and proficiency is ongoing.
Use of RFID tagging results in valuable asset information, including equipment maintenance history.
Camerons field service technicians undergo continuous training throughout their career to ensure competency at the operators location.
A trainee extracts a backpressure valve with a manual lubricator.
3
Trailers are fitted to perform integrated field testing, power torque and high-pressure greasing from a single platform.
Camerons field services fleet maintains an average
of more than 1000 frac jobs per year in the US and
Canada. our test, torque and grease units trucks
and trailers have a maximum test pressure of 5000,
7000, 10,000 or 15,000 psi.
Trucks for Test, Torque and Grease Utility
Cameron has a large fleet of 348-Peterbilt trucks with
sleeper cabs and 25-ft flatbeds. each truck carries the
same equipment package within a smaller length of
vehicle. In addition, the trucks are:
equipped to deliver, lift and place up to 10,000 lb
equipped to perform skid-mounted pressure tests
up to 10,000 lb
equipped to perform skid-mounted pressure tests
up to 15,000 psi for wellheads, valves, BoPs and
casing
equipped to hydraulically torque all flange sizes
Skid-mounted for valve grease operations up to
15,000 psi
equipped with mechanical casing cutters in all sizes
through 13-3/8 in
equipped with a self-contained rotary-screw air
compressor
Trailers for Test, Torque and Grease Utility
Camerons trailers are fitted to perform integrated
field testing, power torque and high-pressure
greasing from a single platform. each trailer is
equipped to carry and pump methanol, glycol and
water. operational and safety upgrades include:
Pump capabilities of 30 gal/min and 15,000-psi
working pressure
Increased fluid capacity (700 gal)
Fluid containment/catch pans
runaway shutdown safeties and pusher fans
modular deck components
F IeLD SerVICeS FLeeT
Trucks are equipped to perform skid-mounted pressure tests for wellheads, valves, BOPs and casing.
Camerons service fleet includes both trucks and trailers for test, torque and grease applications.
4
FLS-R-Frac Gate Valve
manual valve for high-pressure, large-bore applications
allows reduced break-open and running torque
Features flow direction versatility and increased service life
Frac service is severe. Gate valves are exposed to nearly continuous service, flowing and controlling abrasive fluids for long periods of time.
FLS-Frac Gate Valve
Full-bore, through-conduit valve for severe applications
Bi-directional design for flow direction versatility and increased service life
Positive metal-to-metal sealing
FLS-DA2-Frac Gate Valve
Combination of Camerons FLS gate valve with double acting hydraulic actuator
offers reliable control throughout entire valve stroke
remains in position should hydraulic power failure occur
FraC VaLVeS
For more than a century, Cameron has been developing valves
specifically for the oil and gas industry, while earning a reputation for
quality and reliability.
Frac service is just about as harsh as it gets. With the introduction of zip
fracing, gate valves assembled into frac trees and manifolds are exposed
to nearly continuous service, flowing and controlling high-pressure,
high-volume, abrasive frac fluid for days, and even weeks, on end.
Given the erosive, corrosive and sometimes sour nature of typical frac
and flowback fluids, Camerons FLS-Frac, FLS-r-Frac, and FLS-Da2-Frac
gate valves are designed with standard features:
Trimmed for maximum corrosion and erosion protection
Cra inlay in seat pockets and ring grooves for added protection
Zero-chamfer flowbores are utilized in order to mitigate turbulence
that is known to exaggerate erosion
Two grease fitting ports are utilized for flushing and greasing the
valve body cavity
as a result of these unique features designed into Camerons frac
valves, and of the care given to them when they return from
the field for cleaning, disassembly, inspection, reassembly and testing
for the next project, they have grown a reputation for enhanced
reliability.
Erosion Study
Given the inherent severity of frac service and the high cost of failure,
Cameron has anticipated the necessity for all possible failure modes to
be identified and eliminated in the design, manufacture, installation
and maintenance cycles of the equipment, and has undertaken pre-
emptive activities to attain a deep understanding of the way in which
critical components perform in this harsh environment. We then use
that knowledge to provide the quality and reliability that is demanded.
Two of these pre-emptive activities were an erosion study of critical
components to locate and quantify high-pressure slurry damage and
a fatigue analysis to evaluate the effects of overpressuring, erosion
and inadequate flange bolting.
The first study was conducted to investigate relative erosion rates of a
5-1/8 gate valve and a 7-1/16 gate valve when exposed to identical
fluid flow conditions and properties, simulating worst-case frac stage
components at 7500 psi.
5
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M2-1/16 15M
2-1/16 15M5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
2-1/16 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
4-1/16 15M
5-1/8 15M
5-1/8 15M
220 190 182
101
Conventional Frac Tree Composite Frac Tree
Just as selecting the most appropriate frac treatment is
critical to your operation, selecting the best frac tree is
paramount. Cameron offers access to technology and
new innovations that have the potential to be game
changers. Leveraging our reputation for industry
leadership and technically sound products, we actively
resolve the unique challenges of shale oil and gas
development and offer frac tree design options that
conform to your wellsite needs.
Camerons Frac Trees
Camerons solutions have evolved with industry needs,
creating four generations of frac trees, as shown
below. We have evolved our frac tree designs to
include composite frac tree systems as an alternative
to conventional systems.
In a conventional stacked-valve design, advantages can
be seen in the inherent flexibility of the configuration.
By incorporating the master and swab valves and wing
outlets into a solid body, the number of potential
leak-path connections, as well as the tree height and
weight, are reduced. The height and weight available
with compact designs offer safety advantages, such as
ease of handling during installation and elimination of
the need to work at heights.
another innovation, the composite block frac tree,
houses the master and swab valves, as well as the
horizontal wing outlets, into a single block body,
creating a significantly shorter assembly. The reduced
tree height reduces the bending stress transferred
from the goat head to the tree and wellhead
connections below.
FraC TreeS
6
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M2-1/16 15M
2-1/16 15M5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
2-1/16 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
5-1/8 15M
4-1/16 15M
5-1/8 15M
5-1/8 15M
220 190 182
101
Composite Frac Tree F-T90 Horizontal Frac Tree
Compact Frac-Tree Design
Taking the compact concept further, Cameron has
introduced an innovative horizontal design, the F-T90Tm,
which offers an ultra-compact footprint and reduced
height, and also enhances the integrity of overall frac
operations. This tree is built to reduce bending stress
at the tree connection and can be operated with
pneumatic, hydraulic or electric actuation.
The F-T90 horizontal tree represents more than 50%
reduction in size and about 25% in weight from our
first conventional frac tree. It is short, stable, and easily
anchored an ideal configuration for frac-tree service.
The 90-degree goat head is located at the end of the
horizontal section, resulting in the distance across
which the bending loads act being less than half of
that of a conventional stacked-valve frac tree.Camerons F-T90 tree leverages proven FLS-R gate valve design, incorporating metal-to-metal sealing.
Frac Tree Technological Evolution and Innovation
7
A frac manifold is an arrangement of flow fittings and valves installed downstream of the frac pump output header and upstream of each frac tree served by it.
From the first treatment to the last, Cameron strives to
enable operators to improve well economics through
almost continuous utilization of the frac crew and
equipment. The various generations of Camerons
frac manifolds represent our commitment to constant
improvement. modular frac manifolds are designed,
constructed and installed to accommodate as many
wells as required, in essentially any configuration. The
primary variables are frac-pumping service capacity,
nominal size of the frac lines, nominal bore size of the
frac tree, and wellbore characteristics.
Camerons manifolds can be equipped with a safety
ladder and platform to provide safe access to the
valves. also, hydraulic actuation of the valves enables
remote operation, reducing the risk of injury.
Design Features and Benefits
enhances safety of operations
Increases number of fracs performed per day
Provides ease of operation
Decreases number of rigup/rigdown cycles
Decreases pumping downtime
reduces multiple frac lines
Erosion Study
a study was conducted to evaluate the selection
of specific critical components of a known frac
delivery system on the basis of previous experience
and engineering judgment. Input parameters for
the study included such elements as equipment
geometry, materials of construction, flow rate and
fluid characteristics. a computational fluid dynamics
(CFD) model was constructed and used to simulate
the path of the sand particles and thereby the erosion
characteristics of the manifold and valve equipment.
These erosion studies offered an in-depth
understanding of the erosive effects of common frac
slurry on critical elements of manifolds and gate
valves.
Cameron also commissioned an analysis of the
fatigue life of frac manifold components using finite
element modeling. The analysis examined all of the
essential components of frac manifold assemblies
spacer spool, inlet tee, outlet cross, model FLS-r gate
valve and flange bolting. results of the assessments
revealed interesting and pertinent insight into frac
manifold design and maintenance.
The completion of the erosion and fatigue life studies,
in addition to feedback from years of experience,
have provided Cameron with a uniquely complete and
quantitative understanding of the anticipated fatigue
life of the frac manifold data that now are used in
the design of frac and gate valve equipment and in
developing the maintenance procedures that help
extend the life of equipment and provide reliable
field performance.
FraC manIFoLDS
8
Our latest innovation, the Monoline FFDS, presents a safer, faster, cleaner solution than the frac iron method.
Field service technicians assemble the Monoline FFDS.
an example of Camerons constant improvement in
manifold designs is the second generation Frac Fluid
Delivery System (FFDS), a solid monoline solution that
adheres to aPI standards and uses controlled bolted
connections that promote a higher level of system
integrity and safety. Camerons latest innovation the
monolineTm presents a safer, faster, cleaner solution
than the industrys traditional frac iron method in
which the link from the outlet of the frac manifold to
the inlet of the frac tree is made awkward due to the
inherent misalignment between the manifold and the
tree in the vertical and horizontal planes.
The monoline FFDS concept is fairly simple. a series of
5 high-pressure pipe segments are joined together
with 90-degree elbows and swivel flanges. This
configuration allows for the full three degrees of
freedom movement needed to accommodate vertical
and horizontal misalignment between the frac tree
and the frac manifold.
In developing the monoline, Cameron used a variety
of design methods, including finite element analysis
(Fea) and CFD to perform erosion studies on the
system, in order to determine critical stresses and
erosion rates. Field trials that included a frac and
inspection program were undertaken to observe
and analyze performance in actual frac conditions to
optimize life cycle.
Monoline FFDS Design Features and Benefits
Cost effective compared to traditional frac iron
assembled quickly, reducing oPeX and nPT
Significantly de-clutters the work environment
Uses industry standard flanges; no sledge hammers
are involved
monoLIne FraC FLUID DeLIVerY SYSTem (FFDS)
9
a common maintenance practice for other suppliers
of gate valves for hydraulic frac service is to perform a
simple flush and test between frac jobs. This minimal
service practice provides no disassembly, no removal of
trapped sand/debris and very little in terms of quality
control only a hydrostatic pressure test.
Given the severity of the hydraulic fracturing
environment, and the impact to equipment,
Camerons design and quality engineers have compiled
recommended procedures for maintenance of our
frac equipment. These FracServTm procedures establish
a sequence of activities and inspections designed
to ensure that any degradation of frac equipment
is identified and corrected before the equipment is
reassigned to another frac project. adherence to these
service procedures yields Camerons frac valves in
as new condition for each frac project.
The result of Camerons stringent procedures is
reliability that minimizes downtime and extra expense
from your bottom line. our valve success rate is
99.95%. estimates available to us indicate that the
failure rate of non-Cameron frac valves ranges from a
minimum of 10% to more than 30%.
In the absence of FracServ, the potential exists
of having to cease frac operations through a frac
manifold in order to service or replace a component,
which can be expensive. as an example, the time lost
to have a new valve brought to the well site, set a
plug and replace the faulty valve is about the time it
takes to complete a frac stage. In essence, then, the
cost to replace a frac valve is about the same as the
substantial cost of a frac stage.
FraCSerV VaLVe InTeGrITY ProTeCTIon PLan
Equipment is offloaded and checked for NORM. The customer and well name are documented and part number and serial number are verified.
The valve is reassembled with qualified parts.
Dedicated cells are set up to follow definedQA for frac valves. The technician beginsdisassembly.
The valve is tested.
Trained inspectors qualify or disqualify components per FracServ procedures.
Painted valves are tagged with a test tagverifying repair is complete.
10
Left unchecked, frequently fluctuating pressure coupled with corrosive and erosive service can damage the structural integrity of a valves body.
Sand, acid and many other erosive and corrosive elements of a frac job reduce the life of a valves gate and seat, if left untreated.
Sand and other particulate debris left unmonitored can affect the performance of grease fittings over time.
If ignored, the dynamic environment typical of a frac job can significantly fatigue damage bolting.
Without intervention, the extreme nature of frac service can cause pitting and other frac valve seal surface damage over time.
Lacking proper attention, the high-pressure variations and chemical make-up of fluids used during a frac job can reduce the lifespan of elastomers and other soft goods in a frac valve.
FraC FaCTS
11
Cameron customizes flowback and well-testing
equipment and services to meet your individual needs
in every geographical area in which your company
participates. Cameron tailors equipment and services
to your target basin, offering a selection of basin
packages that reflect unique temperature and pressure
needs and the nature of liquid content per operators
basin requirements. our flowback and well-testing
equipment portfolio includes equipment operability
and flexibility to meet a vast array of operating
requirements and conditions. The portfolio is comprised
of only Camerons technology, which means premium
equipment is used on your projects. Cameron follows
a set of standard equipment maintenance procedures,
and our equipment undergoes constant inspection to
offer reliable performance.
Camerons CamSerV field service personnel are
among the most experienced in the industry as a result
of continuous training. our service competency is a
requirement that extends beyond basic training to
include continuous certification throughout technicians
careers. our flowback and well-testing equipment
includes:
10,000 and 15,000-psi upstream equipment
Single- and double-barrel plug catchers
Vertical and spherical 5800-, 10,000- and 15,000-psi sand separators
Hydraulic actuated and manual gate choke manifolds
Horizontal and vertical 2-, 3- and 4-phase 500-, 720-, 740-, 1440- and 2000-psi well-test separators
Hydraulic and pneumatic emergency Shutdown Valves (eSD)
Indirect line heaters
Flare stacks
Frac tanks with gas busters
Hydraulic choke and control valves
Trained and experienced flowback and well-test technicians
Technician office and sleeping trailers
Before flowback of the high-pressure frac water can
begin, its necessary for the coiled tubing operator to
drill out or mill out the composite zone plugs, which
will allow the well fluids to flow back to the surface.
High-pressure frac water flowing from the frac stack
or production tree is pressure and volume controlled
by the choke manifold according to predetermined
customer requirements and is diverted to water storage
tanks for treatment or disposal. once water, oil and
natural gas are present, well testing can begin.
During the well-testing phase, the wellstream continues
to be pressure and volume controlled by the choke
manifold according to customer requirements, and is
directed into the test separator where the oil, water
and natural gas are separated. The liquids are accurately
measured and discharged to an existing gas sales
pipeline through a metering station or flared if a gas
pipeline isnt available. During well testing, pressures,
temperatures, specific gravities, liquid volumes and
flow rates are measured and documented at regular
intervals. This information is available to the customer
in real-time transfer with Camerons electronic data
acquisition equipment (Scanner and microeFmTm) and
Fekete well testing and rates transient analysis software.
The Fekete analysis report enables a comprehensive
understanding of reservoirs, completion efficiency and
optimization potential.
FLoWBaCK anD WeLL TeSTInG
3
4
4
5
6
7
8
2
1
12
1. Plug Valve Choke Manifoldsmanual quarter-turn plug valve choke manifolds are
used to control downstream pressure and volume
control during flowback and well testing.
Up to 15,000-psi working pressure standard-service plug valves
10,000-psi working pressure naCe (sour service) plug valves
Designed to provide pressure isolation and control redundancy
manual bypass configured in assembly
offers operator-friendly quarter-turn manual actuation
easy to repair and maintain
2. Plug CatchersPlug catchers support well cleanup by filtering isolation
plug remnants and fragments of casing, cement and loose
rock in the area of the perforations. our design features:
Single barrel with bypass or dual barrel (allows for continuous filtration during blow-down activities)
eliminates potential equipment damage or blockage by removing large solid debris immediately after the
frac stack
10,000- to 15,000-psi working pressure
Sweet or sour service
Plug valve- or gate valve-based design
available with hydraulically controlled dump
3. Sand SeparatorsSand separators are designed to remove sand and other
solids from flowback process fluid. our designs feature:
Centrifugal force to spin solids out of the wellstream
Single or dual systems
Vertical or spherical designs
Can withstand full wellhead pressures
automatic dumping
3
2
1
13
4. Hydraulic-Actuated Gate-Valve Choke Manifolds
These unique valves are designed for remote control
of downstream pressure and volume control during
flowback and well testing. a choke control trailer and
hydraulic choke control trailer are used in conjunction
with this equipment.
Up to 15,000-psi working pressure
Cameron gate valves and chokes
2-9/16 or 3-1/16 dual-choke manifold with bypass
Skid-mounted leveling jacks provided as standard
5. Well Test SeparatorsHigh and/or low working-pressure vessels are used to
separate oil, water, gas and sometimes solids (sand) into
individual streams for more accurate measurement and
discharge control.
rated for 500- to 2000-psi working pressure
available in skid-mounted or trailer-integrated designs
naCe compliant equipment available
2-, 3- or 4-phase separator test units
Horizontally or vertically skid mounted
Currently available in several sizes
6. Emergency Shutdown Valves (ESD)eSD valves are used to isolate pressure and flow from a
particular source during an emergency situation.
Integrated into the design of the well-testing equipment
Can be moved to any location upstream of testing units
5
6
4
14
7. Hydraulic Choke Control TrailersThese trailers are portable office trailers rigged up
to control valve and choke position/operation, data
acquisition, and monitoring of the entire jobsite.
Four-station hydraulic power unit air pumps eSD safety system can be tied to controls Can provide remote data capturing and transmissions Provides control and monitoring of hydraulic actuated
valves and chokes
Provides temperature and pressure monitoring Integrated with the electronic flow meter (eFm) on the
test separator
Skid-mounted hydraulic high-pressure units (HPUs) with lifting frames for spill containment and fast-acting
remote actuation
8. Flare SystemsFlare systems are used to burn or incinerate natural gas
and natural gas vapors.
Dimensions: 3, 4 or 6 diameter stacks with multiple heights
Use is based upon customers export strategy
equipped with an auto-ignition system
Can be easily relocated between sites
7
8
15
FRAC SUPPORT SERVICECENTERS IN NORTH AMERICARegardless of where your project is located in North
America or how complex the frac operation, Camerons
equipment and services can get you to the finish line.
Our start-to-finish offering includes a vast network of
more than 35 locations. Each facility offers Camerons
expertise and commitment to provide innovative solutions,
quality and reliable equipment, and competent service.
Devoni
an
Marce
llus
Utica
Appalac
hian Bas
in
New
Albany
Illinois
Basin
Michigan
Basin
Antrim
Utica
Fred
rick
Broo
k
Hort
onBl
uff
Valley and
Ridge
Province
Black Warrior
Basin
Floyd-Neal
Chattanooga
Chattanooga
Floyd-Neal/
Chattanooga
Conasauga
Texas-Louisiana-M
ississippi
Salt Basin
Tuscaloosa
Haynesville-
Bossier
EagleFord
WesternGulf
Pearsall
Ft. WorthBasin
Barnett
Ardmore Basin
PermianBasin
Palo DuroBasin Bend
Avalon-Bone Spring
Barnett &Woodford
Barnett &Woodford
MarfaBasin
WoodfordWoodford
Woodford
AnadarkoBasin
CherokeePlatform
Excello-Mulky
Excello-Mulky
Forest CityBasin
San Juan Basin
LewisRatonBasin
PierreParadox Basin
CaneCreek
UintaBasin
ManningCanyon
Mancos
Hermosa
PiceanceBasin
DenverBasin
Niobrara
Mowry/Niobrara
Wind RiverBasinHilliard/Baxter/MancosGreenRiverBasin
MowryFormation Niobrara/Mowry
Formation
Niobrara/Park
Basin
Powder RiverBasin
Big HornBasin
Cody Heath Formation
Bakken
WillistonBasin
Gammon
MontanaThrust Belt
Niobrara
DoigPhosphate
ColoradoGroup
ColoradoGroup
Horn RiverBasin
Montney
Lower Besa River
San JoaquinBasin
Monterey,Santa Maria,Ventura,Los AngelesBasins
MontereyTemblor
Arkoma Basin
Fayetteville
U L F O F E X I C OG M
T L A N T I C
C E A N
AO
A C I F I C
C E A NOP
LEGEND
Sales Support
Aftermarket
WASH I N G TON
A L B E R TA
S A S KAT CH EWAN
NORTHWE S TT E R R I T O R I E SNUNAVU T
MAN I T O BA
ON TA R I O
QU EB E C
N EW
B RUN
SWI CK
NOVA
S COT IA
P RI N
C E E
D WA R
D
I SL A
N D
NE W
F OU
ND
L AN
D
AN
D L
AB R
AD
OR
B R I T I S HCO L UMB I A
O R E G O N
N E V A D A
A R I Z O N AN E W M E X I C O
U T A H
C O L O R A D O
I D A H O
M O N T A N A
W Y O M I N G
N O R T HD A K O T A
S O U T HD A K O T A
N E B R A S K A
K A N S A S
O K L A H O MA
T E X A S
CA
LI
FO
RN
IA
A R K A NS A S
M I S S I S SI P P I
L O U I S I A N A
M I S S OU R I
I O W A
M I NN E SO TA
W I S CON S I N
I L L IN O I S
I N D IA NA
K EN TU C K Y
T E NNE S S E
E
A L A BAMA
G EORG I
A
M I CH I G
AN
F L ORI DA
SOUTH
CA RO L I
N A
N O RT H
C A RO L I
N A
V I RG I N
I AWEST
VIRGINIA
OH IO
P E NN S
Y LVAN
I A
MARY L
ANDD E L
AWAR E
N EW
J E RS E Y
N EW
Y OR K
N.H.
VT.
MASS.
CONN
.R.I
.
MA IN E
AL AS KA
16
FRAC SUPPORT SERVICECENTERS IN NORTH AMERICARegardless of where your project is located in North
America or how complex the frac operation, Camerons
equipment and services can get you to the finish line.
Our start-to-finish offering includes a vast network of
more than 35 locations. Each facility offers Camerons
expertise and commitment to provide innovative solutions,
quality and reliable equipment, and competent service.
Devoni
an
Marce
llus
Utica
Appalac
hian Bas
in
New
Albany
Illinois
Basin
Michigan
Basin
Antrim
Utica
Fred
rick
Broo
k
Hort
onBl
uff
Valley and
Ridge
Province
Black Warrior
Basin
Floyd-Neal
Chattanooga
Chattanooga
Floyd-Neal/
Chattanooga
Conasauga
Texas-Louisiana-M
ississippi
Salt Basin
Tuscaloosa
Haynesville-
Bossier
EagleFord
WesternGulf
Pearsall
Ft. WorthBasin
Barnett
Ardmore Basin
PermianBasin
Palo DuroBasin Bend
Avalon-Bone Spring
Barnett &Woodford
Barnett &Woodford
MarfaBasin
WoodfordWoodford
Woodford
AnadarkoBasin
CherokeePlatform
Excello-Mulky
Excello-Mulky
Forest CityBasin
San Juan Basin
LewisRatonBasin
PierreParadox Basin
CaneCreek
UintaBasin
ManningCanyon
Mancos
Hermosa
PiceanceBasin
DenverBasin
Niobrara
Mowry/Niobrara
Wind RiverBasinHilliard/Baxter/MancosGreenRiverBasin
MowryFormation Niobrara/Mowry
Formation
Niobrara/Park
Basin
Powder RiverBasin
Big HornBasin
Cody Heath Formation
Bakken
WillistonBasin
Gammon
MontanaThrust Belt
Niobrara
DoigPhosphate
ColoradoGroup
ColoradoGroup
Horn RiverBasin
Montney
Lower Besa River
San JoaquinBasin
Monterey,Santa Maria,Ventura,Los AngelesBasins
MontereyTemblor
Arkoma Basin
Fayetteville
U L F O F E X I C OG M
T L A N T I C
C E A N
AO
A C I F I C
C E A NOP
LEGEND
Sales Support
Aftermarket
WASH I N G TON
A L B E R TA
S A S KAT CH EWAN
NORTHWE S TT E R R I T O R I E SNUNAVU T
MAN I T O BA
ON TA R I O
QU EB E C
N EW
B RUN
SWI CK
NOVA
S COT IA
P RI N
C E E
D WA R
D
I SL A
N D
NE W
F OU
ND
L AN
D
AN
D L
AB R
AD
OR
B R I T I S HCO L UMB I A
O R E G O N
N E V A D A
A R I Z O N AN E W M E X I C O
U T A H
C O L O R A D O
I D A H O
M O N T A N A
W Y O M I N G
N O R T HD A K O T A
S O U T HD A K O T A
N E B R A S K A
K A N S A S
O K L A H O MA
T E X A S
CA
LI
FO
RN
IA
A R K A NS A S
M I S S I S SI P P I
L O U I S I A N A
M I S S OU R I
I O W A
M I NN E SO TA
W I S CON S I N
I L L IN O I S
I N D IA NA
K EN TU C K Y
T E NNE S S E
E
A L A BAMA
G EORG I
A
M I CH I G
AN
F L ORI DA
SOUTH
CA RO L I
N A
N O RT H
C A RO L I
N A
V I RG I N
I AWEST
VIRGINIA
OH IO
P E NN S
Y LVAN
I A
MARY L
ANDD E L
AWAR E
N EW
J E RS E Y
N EW
Y OR K
N.H.
VT.
MASS.
CONN
.R.I
.
MA IN E
AL AS KA
17
2013 Cameron | Cameron and Scanner are registered trademarks of Cameron. FLS, FLS-r, FracServ, F-T90, monoline, microeFm and CamLInK are trademarks of Cameron. | SWPP 1m 12/13 aD00742SUr
HSE Policy Statementat Cameron, we are committed ethically, financially and personally to a working environment where no one gets hurt and nothing gets harmed.
HEA
LTH
SA
FETY
A
ND ENV
IRONMENTAL EX
CELLEN
CE
CAMERON
3505 W. Sam Houston Pkwy. n. Houston, TX 77043 USaTel 1 713 469 7000
no. 2 Gul CircleJurong Industrial estateSingapore, 629560SingaporeTel 65 6861 3355
Queen Street, StourtonW. Yorkshire LS10 ISBLeeds, LS10 1SBengland, UKTel 44 113 270 1144
Learn more about Cameronsfrac support services at:www.c-a-m.com