FOR PRIVATE CIRCULATION ONLY AUGUST 2017
Official News Letter of Amtech Electronics (India) Ltd., Gandhinagar, Gujarat (India)
AN ISO 9001 : 2008 COMPANYQM 003
Piyush Patel
Page 2
Customer’s Voice
Page 3
Page 4
Appl. Case Study
Page 5
Amtech Power
Page 6
Product Overview
Page 7
Page 8
PresenceAcross the Nation
Inside
Editor:Atul Suthar
From the Desk of Managing Director
Swami Ramdas, the renowned Guru of Chhatrapati Shivajihad come to one village. As per his daily routine he went toone home and asked for alms. The housewife came out andgave some food in the form of alms to Swami Ramdas andrequested him to give some advice to her for her ultimatewell-being. Swamiji thought for a while and told her that hewill do so on the next day. Next day Swamiji went to the samehome and asked for the alms.
The housewife came out with delicious food to give alms. Swamiji held in his hand apot which was dirty with mud. The lady was surprised and said, “Swamiji, how can Iserve you such a delicious food in this dirty pot? Let me get another one.” “No”, repliedSwamiji, “Serve me in the same pot.” “Then let me at least clean it before I serve foodin it”, said the lady. “This is exactly my advice to you. If you want to fill in good thoughtsin your mind, it should be clean to receive them in”, replied Swamiji. The housewife,full of devotion to Swamiji, touched his feet.
- Amtech Family
Power QualityActive Harmonic Filter,
Active Front End Converter
IndustrialAutomation
Controlling
Operating
Driving
Networking
Motion ControlAC Drive, MVD & Soft Starter
ACTIVE FRONT END CONVERTER
AXPERT-HIVERT MVD
ACTIVE HARMONIC FILTER
PLC SCADA, HMI
AXPERT-EAZY AXPERT-VT 240S AXPERT-OPTI TORQUE
AN ISO 9001 : 2008 COMPANYQM 003
STATCON: MULTI-FUNCTIONAL ACTIVESTATIC VAR COMPENSATOR
AMTECH
IndustrialElectronics
Design & Developmentfor Customers in
Power Electronics
TRACTION DRIVE WIND POWER CONVERTER SOLAR INVERTER HIGH VOLTAGE POWER SUPPLY
HappyRaksha Bandhan
HappyJanmashtami
HappyIndependence Day
Pateti Mubarak HappyGanesh Chaturthi
Customer’s Voice
Kiln Drive -Twin Drive Control
You question,we answer
You can analyzethe past, but you
have todesign the future.
Field ProblemCase Study
Energy saving inMill Vent Fan
VIVIMED LIFE SCIENCESPRIVATE LIMITED
2
CUSTOMER’S VOICE
3
FIELD PROBLEM CASE STUDY
Title : Solution for Field Problem : A Case Study
Industry : Rayon
Application : Pulper
Problem :
This case study is an eye-opener, telling what happens due to not giving adequate time for checking electricalconnections before switching ON the power.
In a Rayon manufacturing plant there was failure of 100 HP VFD of X company. The VFD was working on Pulperapplication. Immediately make VFD was shifted to replace the failed VFD. service engineerAmtech Amtechwas called to the site in the midnight to start the VFD. When he checked up the cable coming from the motor, hedid not get proper impedance on the millimeter. He told the authorities of the customer present at the site, that hewill like to check up input output connections of the drive thoroughly before switching it ON. The authorities toldthe engineer, that there is starter between the VFD and motor, that is why the motor winding impedance was notshown on the millimeter and there is no time for any further check up as they wanted to start the stopped processto avoid any further production loss.
They drove back the engineer to Guest house, saying that they will call him back once they are ready. Theengineer told them that let the output of VFD be disconnected till they are ready to start the VFD.
Unfortunately when the customer switched ON the power, there was heavy blast and the main incomer tripped.On investigation, it was found that the power supply cable was not going to VFD but it was lying on the metallicplate, meant for grounding, with its terminals in open condition! The VFD input cable was different. Hence whenthe power was switched ON all the three phases were shorted together to ground, creating heavy blast and thetotal plant was in dark.
There was equal chance that input power cable could have been connected to the output of VFD,Amtechdamaging it totally. To restore the plant it took two hours, while the checking of cables, as per engineer,Amtechcould have taken only few minutes and could have avoided the blast.
Morale:
Creating unnecessary pressure to start the process and not giving the required small time for due check ups canlead to disaster. One can be in a hurry, but one should not be in a haste.
4
Payback period approximately 4 Months
APPLICATION CASE STUDY
Title : Energy saving in Mill Vent Fan DOC.NO. : CS-244
Industry : Cement
Application : Mill Vent Fan
Motor rating : AC Induction Motor, 3-Phase
75kW :
415Volt :
1480RPM :
50Hz :
123Amp :
Previous system : Motor was running on Star Delta Starter.
Problem observed : 1. High maintenance cost.
2. Energy losses due to flow control by damper.
Present system : Amtech 90 kW,AXPERT-EAZY VFD used in place of Star Delta Starter.
kW (Consumption) Damper Position
Previous system (Without drive) : 64 kW 78 % Open
Present system (With drive) : 41 kW 100 % Open
System block diagram :
Merits of new system : 1. Easy & smooth operation.
2. Energy saving due to flow control by VFD.
Economical analysis :
�Energy consumption without VFD - P1 = 64 kW
�Energy consumption with VFD - P2 = 41 kW
�Energy saving per day ((P1-P2)*24) = 552 Units.
�Saving per day @ Rs. 4/- Unit = Rs. 2208/-
�Saving per year (Approx. 300 Days) = Rs. 6,62,400/-
75 kW, 3-PHASEINDUCTION MOTOR
AXPERT-EAZY
3-PHASE,
415 V,
AC SUPPLY
90 kWMILL VENT FAN
AMTECH POWER VISION
5
Digital Excitation Control System (2A+2M) supplied by M/s AmtechPower Limited Gandhinagar for 1.8 MW Hydro Project A/C ChikothraHydro (Project, KSEB) is performing fully satisfactory since 2 years.
It is certified and confirmed that all the system have found reliable andsatisfactory in working at the Power Plant. The technical team of Amtechpower is competent enough to design and manufacturing DigitalExcitation Control System. The services provided by Amtech Power aresignificant and satisfactory.
6
PRODUCT OVERVIEW
The new generation of control system, developed by Amtech Electronics (India) Ltd, integrated the operation ofKiln application in cement Industries with using variable frequency drive and controlling.
For the kiln application, DC motor and drive are used due to their excellent torque speed characteristics, but themaintenance of DC motor is a big issue. Customer replaced DC motor and drive with 220 kW, 415 V AC Motorand VFD to run the kiln. Still, they could not increase the speed of kiln.
Amtech installed additional 110 kW auxiliary motor and VFD. Additional controller used for load sharing.
Feature:
� Smooth speed control of kiln through two VFDs and motor of different ratings and specs.
� No need for additional cost or investment.
� Latest series variable frequency drive with state-of-the-art engineered panel with protection from
dusty environment, ensures trouble free operation of the kiln.
� Built in PLC function of Axpert-Eazy VFD used to provide required interlock to the system.
� Variable frequency drive control eliminates the problems of motor, mechanical losses.
Benefits:
� Assistance from concept to commissioning from Amtech
� Speed of kiln increased to 4 RPM, resulting in higher production
� New system with existing components
� Higher reliability - Less Mechanical wear / tear – more uptime
� Full motor protection
� Smooth kiln operation
� Energy saving
� Easy troubleshooting
� Quick and safe commissioning
� Qualified after-sales service from Amtech
Challenges:
� High torque to increase kiln speed – up to 4 RPM.
� Kiln bending due to single point torque.
� Start up and interlocking of both VFDs, front andback part of process
Solution:
� Additional 110 kW auxiliary motor installed.
� Axpert controller used to match the RPM andtorque of both motors for proper load sharing.
� Built-in PLC function of Axpert-Eazy VFD used toprovide required interlock to the system.
Limitations of previous system:
� The speed of kiln was not possible to increase beyond 3 RPM
� No possibility of increasing motor capacity due to limitation of torque as kiln may bend.
� Availability of motor / gearbox was a major issue.
Kiln Drive-Twin Drive ControlWhy to use DC Drives for kiln application ??
AMTECH has solutions with AC Drive + Motor !!!
7
How do you rate our product quality?
� Excellent
� Good
� Not good
� Cannot give feedback
� Will refer the product to others companies
� Any other comments
How do you find our newsletter?
� Excellent
� Good
� Not worth reading
� Any other comments
Your Valuable Feedback
YOU QUESTION, WE ANSWER
Kindly email your feedback to [email protected]
Name & Signature: Designation: Date:
Contact Number: Email:
Question
What is the advantage of “S-curve” feature in variable frequency drive?
Answer:
Whenever an AC motor accelerates or decelerates it generates a jerk which gets applied to the load connectedto motor. In case of applications such as a conveyer belt carrying delicate glass bottles or a lift carrying humanbeings who are sensitive to jerks, S-curve type of acceleration or deceleration characteristic is used to reducethe jerk to an extent that the load does not feel it. The variable frequency drive is provided with this feature whichis preferred in lift and bottling plant applications.
Gandhinagar
Atlanta
GandhinagarAhmedabad
Mumbai
Surat
MuzaffarnagarDelhi(Gurgaon)
Vadodara
Indore
Jamnagar
Udaipur
Kolkata
Nagpur
Pune
Hyderabad
Vapi Raipur
Bhopal
Jamshedpur
JaipurLucknow
Vizag
Bangalore
Chennai
Belgaum
PondicherryTrichy
AurangabadNasik
Chandigarh
Veraval
PRESENCE ACROSS THE GLOBE
Book - PostTo
From
Works & Regd. Office :
Amtech Electronics (India) Ltd.E-6, GIDC Electronics Zone,
+91 79 23289101, 23289102, 23289103+91 79 [email protected]
PhoneFaxE-MailWeb
::::
Gandhinagar-382 028, Gujarat (India)
Head Office
Branch Office
Dealer
System Integrator
Resident Engineer
Global Distribution
M. D. Kamath
-
Regional Offices
Contact Person Phone No. (O) Mobile No. E-mail
022-28846083Vrajesh Yadav 09819900501
09108051977
09582888030
Mumbai
Bangalore
Chennai
Delhi
-
-
T. S. Sridhar 044-26358919 09840618533
.
Umesh Bhatia 09589344318Indore / Raipur [email protected]
S. Senthil Kumar 044-26358919 09940229955 [email protected]
H.O. and Service Center
Contact Person Phone No. (O) Mobile No. E-mail
Bhavana Thakkar 09909975944H.O. Gandhinagar [email protected]
Rajesh Moradiya 09909973780Amtech Service CenterGandhinagar
G. Sateesh Kumar 09573900222Hyderabad [email protected]
Kaushik C. 09932820680Kolkatta [email protected]