approval Products Solutions Services Application / Function Overview Technical data Dimensions Electrical connection Price table Contact Go to shop Technical Datasheet TD 00001E/24/EN/01.13 Maintenance-free Stainless steel (fork 1.4571, housing 1.4404) Unaffected by build-up, turbulences and gas bubbles Complete product information: www.e-direct.us/ftl260 Specs at a glance: Product: Liquids Mounting: Vessels or pipes (from DN50) Product density: ≥ 0.7 g/cm³ (0.7 SGU) Product temperature: -40 to +300 °F (-40 to +150 °C) Product viscosity: ≤ 10000 mm²/s (10000 cSt) Process pressure: -14.5 to +580 psi (-1 to +40 bar) Compact universal limit switch for liquids Liquiphant T FTL260 $ 277.00
Transcript
Page 1: FTL260

approval

Products Solutions Services

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Technical DatasheetTD 00001E/24/EN/01.13

•Maintenance-free• Stainless steel (fork 1.4571,

housing 1.4404)•Unaffected by build-up, turbulences

and gas bubbles

Complete product information:www.e-direct.us/ftl260

Specs at a glance:

•Product: Liquids•Mounting:

Vessels or pipes (from DN50)•Product density:

≥ 0.7 g/cm³ (0.7 SGU)•Product temperature:

-40 to +300 °F (-40 to +150 °C)•Product viscosity:

≤ 10000 mm²/s (10000 cSt)•Process pressure:

-14.5 to +580 psi (-1 to +40 bar)

Compact universal limit switch for liquids

LiquiphantTFTL260

$ 277.00

Page 2: FTL260

Liquiphant T FTL260:programmable logic controller (PLC), relay, solenoid valve or AS-i bus

U~

U=

LiquiphantTFTL260 2

Overview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Application / Function

Application The Liquiphant T FTL260 is a reliable point level switch for liquids. It can be used in tanks and pipes as pump protection and as an alternative to float switches in storage vessels. The FTL260 is unaffected by build-up, turbulence and gases and does not rely upon the electrical properties of the liquid.

ApplicationexampleFunction The integrated electronics detect the change in the fork’s vibrating frequency when they are covered and uncovered by the liquid. The FTL260 can be directly connected to miniature contactors, solenoid valves or to a PLC.

Page 3: FTL260

LiquiphantTFTL260 3

Application / FunctionOverview

Electrical connection Price table ContactGo to shop

Technical data Dimensions

Output AC versionPower supply 19 to 253 V AC, 50/60 Hz when blockedCurrent consumption Max. 4 mA (stand-by)Connectable load Short-term (40 ms): max. 1.5 A, max. 375

VA at 250 V or max. 36 VA at 24 V (no short-circuit protection);continuous: max. 87 VA at 250 V, max. 8.4 VA at 24 V, min 2.5 VA at 250 V (10 mA), min. 0.5 VA at 24 V (20 mA)

Voltage drop Across FTL260 max. 12 VResidual current Max. 4 mA with open thyristor (stand-by)

Output DC versionPower supply 10 to 55 V, ripple max. 1.7 V, 0 to 400 HzCurrent consumption Max. 15 mA, reverse polarity protectionConnectable load Short-term (1s): max. 1 A, max. 55 V

(overload and short-circuit protection); continuous: max. 350 mA

Residual voltage < 3 V (with closed transistor)Residual current < 0.1 mA (with open transistor)

Operating conditionsHysteresis Approx. 4 mm with vertical mounting from

topOrientation As requiredAmbient temperature -40 to +158 °F (-40 to +70 °C)Temperature of product

-40 to +300 °F (-40 to +150 °C)

Operating pressure -14.5 to +580 psi (-1 to +40 bar)Density of product Min. 0.7 g/cm³ (0.7 SGU)Viscosity of product Up to 10000 mm²/s (cSt)Storage temperature -40 to +185 °F (-40 to +85 °C)Climatic protection To IEC 68, part 2-38Ingress protection With plug IP 67

with cable (5 m/16 ft) IP 68

Technicaldata Dimensions(ininches)andmaterial

4.695.04

Switchpoint

Green LED:operating mode

Flat sealelastomer-fiber

Red LED to indicate switching mode: circuit open

The switching function can be checked externally by placing a strong magnet on the housing

The plug housing can also be fitted offset ±90° Installation according to instruction manual

1.4571

1.4404

AF 41G 1A PPSU

S N0.98

1.10

0.78

0.35

Ø 1

.57

0.75

GeneralFail-safe mode Minimum or maximum fail-safe mode,

depending on load connection, FTL260/AC never connect without load (contacters, relays etc.)

Power failure Output closedWeight Approx. 0.45 kg (0.99 lbs)Standard 4-pole plug connection to DIN 43650-A, ISO

4400 with cable gland PG 11, for cable diameters from 6 up to 9 mm (0.24 to 0.35"), max. wire cross section 1.5 mm²

With cable 5 m (16 ft) permanently att. cable, 4×0.75 mm²

Switching time Approx. 0.5 s when covered; 1.0 s when free

ApprovalsWHG approval Overspill protection to §19 WHG (Germany)

Permissiblevaluesfortemperatureandpressure

pe

bar

TB

°CTB

°C

TU

°C

-40 0 50 100 150

40

-40-40

0 50 100 150

7050

Ambient temperature Operating pressure

Permissible values for ambient temperature TU at housing are dependent on the operating temperature TB in the tank

Permissible values for operating pressure Pe are dependent on the operating temperature TB in the tank

Page 4: FTL260

LiquiphantTFTL260 4

Application / FunctionOverview Technical data Dimensions

ContactGo to shopElectrical connection Price table

Pricetable

Moreproductstocompleteyourmeasuringpoint…

Liquiphant FTL260 Order no. Price/pcs. in USDCable Entry Switch Output 1 to 5 6 to 10 11 to 35Plug ISO4400 NPT½, NEMA4X 2-wire 19-253 V AC FTL260-3114 315.00 293.00 277.00

3-wire PNP 10-55 V DC FTL260-3124 315.00 293.00 277.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.

Complete product information:www.e-direct.us/ftl260

Electricalconnection

+

+

R

R

Max.

Max.

Min.

Min.

N

PE PE

NR

L1

L+

PE

L-

L+

PE

L-

RL1

min

.

19 V

GNYE

BN

(BK) (2) 2

1 1BU

GNYE

BN

BK

BU

GNYE

(BN) (3)3

2 2

1 1

33

BK

BU

GNYE

BN

BK

BU

2

2 2

20

0 0

0A1A1

0,5A

0,5A

AC version

DC version

Max. = maximumsafety circuit

Min. = minimum safety circuit

2 = cable connection

BU = blueBK = blackBN = brownGNYE = green/yellow

0 = plug connection

R = external load

min

.19

V

Positive signal at the switching output of Liquiphant (PNP)

FTL260/AC never connect without load!

TemperatureswitchThermophant T TTR31

DigitalindicatorRIA46

VibroniclimitswitchSoliphant T FTM20

Page 5: FTL260

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Contact

E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143

Direct order

Internet www.e-direct.usby phone 888- EH-DIRECT

(343-4732)per Fax 317-535-8498E-Mail [email protected]