Technical DatasheetTD 00001E/24/EN/01.13
•Maintenance-free• Stainless steel (fork 1.4571,
housing 1.4404)•Unaffected by build-up, turbulences
and gas bubbles
Complete product information:www.e-direct.us/ftl260
Specs at a glance:
•Product: Liquids•Mounting:
Vessels or pipes (from DN50)•Product density:
≥ 0.7 g/cm³ (0.7 SGU)•Product temperature:
-40 to +300 °F (-40 to +150 °C)•Product viscosity:
≤ 10000 mm²/s (10000 cSt)•Process pressure:
-14.5 to +580 psi (-1 to +40 bar)
Compact universal limit switch for liquids
LiquiphantTFTL260
$ 277.00
Liquiphant T FTL260:programmable logic controller (PLC), relay, solenoid valve or AS-i bus
U~
U=
LiquiphantTFTL260 2
Overview Technical data Dimensions
Electrical connection Price table ContactGo to shop
Application / Function
Application The Liquiphant T FTL260 is a reliable point level switch for liquids. It can be used in tanks and pipes as pump protection and as an alternative to float switches in storage vessels. The FTL260 is unaffected by build-up, turbulence and gases and does not rely upon the electrical properties of the liquid.
ApplicationexampleFunction The integrated electronics detect the change in the fork’s vibrating frequency when they are covered and uncovered by the liquid. The FTL260 can be directly connected to miniature contactors, solenoid valves or to a PLC.
LiquiphantTFTL260 3
Application / FunctionOverview
Electrical connection Price table ContactGo to shop
Technical data Dimensions
Output AC versionPower supply 19 to 253 V AC, 50/60 Hz when blockedCurrent consumption Max. 4 mA (stand-by)Connectable load Short-term (40 ms): max. 1.5 A, max. 375
VA at 250 V or max. 36 VA at 24 V (no short-circuit protection);continuous: max. 87 VA at 250 V, max. 8.4 VA at 24 V, min 2.5 VA at 250 V (10 mA), min. 0.5 VA at 24 V (20 mA)
Voltage drop Across FTL260 max. 12 VResidual current Max. 4 mA with open thyristor (stand-by)
Output DC versionPower supply 10 to 55 V, ripple max. 1.7 V, 0 to 400 HzCurrent consumption Max. 15 mA, reverse polarity protectionConnectable load Short-term (1s): max. 1 A, max. 55 V
(overload and short-circuit protection); continuous: max. 350 mA
Residual voltage < 3 V (with closed transistor)Residual current < 0.1 mA (with open transistor)
Operating conditionsHysteresis Approx. 4 mm with vertical mounting from
topOrientation As requiredAmbient temperature -40 to +158 °F (-40 to +70 °C)Temperature of product
-40 to +300 °F (-40 to +150 °C)
Operating pressure -14.5 to +580 psi (-1 to +40 bar)Density of product Min. 0.7 g/cm³ (0.7 SGU)Viscosity of product Up to 10000 mm²/s (cSt)Storage temperature -40 to +185 °F (-40 to +85 °C)Climatic protection To IEC 68, part 2-38Ingress protection With plug IP 67
with cable (5 m/16 ft) IP 68
Technicaldata Dimensions(ininches)andmaterial
4.695.04
Switchpoint
Green LED:operating mode
Flat sealelastomer-fiber
Red LED to indicate switching mode: circuit open
The switching function can be checked externally by placing a strong magnet on the housing
The plug housing can also be fitted offset ±90° Installation according to instruction manual
1.4571
1.4404
AF 41G 1A PPSU
S N0.98
1.10
0.78
0.35
Ø 1
.57
0.75
GeneralFail-safe mode Minimum or maximum fail-safe mode,
depending on load connection, FTL260/AC never connect without load (contacters, relays etc.)
Power failure Output closedWeight Approx. 0.45 kg (0.99 lbs)Standard 4-pole plug connection to DIN 43650-A, ISO
4400 with cable gland PG 11, for cable diameters from 6 up to 9 mm (0.24 to 0.35"), max. wire cross section 1.5 mm²
With cable 5 m (16 ft) permanently att. cable, 4×0.75 mm²
Switching time Approx. 0.5 s when covered; 1.0 s when free
ApprovalsWHG approval Overspill protection to §19 WHG (Germany)
Permissiblevaluesfortemperatureandpressure
pe
bar
TB
°CTB
°C
TU
°C
-40 0 50 100 150
40
-40-40
0 50 100 150
7050
Ambient temperature Operating pressure
Permissible values for ambient temperature TU at housing are dependent on the operating temperature TB in the tank
Permissible values for operating pressure Pe are dependent on the operating temperature TB in the tank
LiquiphantTFTL260 4
Application / FunctionOverview Technical data Dimensions
ContactGo to shopElectrical connection Price table
Pricetable
Moreproductstocompleteyourmeasuringpoint…
Liquiphant FTL260 Order no. Price/pcs. in USDCable Entry Switch Output 1 to 5 6 to 10 11 to 35Plug ISO4400 NPT½, NEMA4X 2-wire 19-253 V AC FTL260-3114 315.00 293.00 277.00
3-wire PNP 10-55 V DC FTL260-3124 315.00 293.00 277.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.
Complete product information:www.e-direct.us/ftl260
Electricalconnection
+
+
R
R
Max.
Max.
Min.
Min.
N
PE PE
NR
L1
L+
PE
L-
L+
PE
L-
RL1
min
.
19 V
GNYE
BN
(BK) (2) 2
1 1BU
GNYE
BN
BK
BU
GNYE
(BN) (3)3
2 2
1 1
33
BK
BU
GNYE
BN
BK
BU
2
2 2
20
0 0
0A1A1
0,5A
0,5A
AC version
DC version
Max. = maximumsafety circuit
Min. = minimum safety circuit
2 = cable connection
BU = blueBK = blackBN = brownGNYE = green/yellow
0 = plug connection
R = external load
min
.19
V
Positive signal at the switching output of Liquiphant (PNP)
FTL260/AC never connect without load!
TemperatureswitchThermophant T TTR31
DigitalindicatorRIA46
VibroniclimitswitchSoliphant T FTM20
Application / FunctionOverview Technical data Dimensions
Electrical connection Price table ContactGo to shop
Contact
E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143
Direct order
Internet www.e-direct.usby phone 888- EH-DIRECT
(343-4732)per Fax 317-535-8498E-Mail [email protected]