www.fakro.com
FTP-VZ-Wave
FTU-VZ-Wave
ENGLISH
Electricwindow
UserManual
©2016FAKRO®21.01.16NC837-GB
Themanufacturerguaranteescorrectdevicefunctioning.Italsoundertakestorepair
orreplacefaultydeviceifdamageisaresultofmaterialorstructuralfaults.Thewarranty
periodis24monthsfromthedateofpurchase,fulfillingthefollowingconditions:
•Installationhasbeenperformed
byan
authorisedindividual,aspermanufacturer
recommendations.
•Sealsremainintactandnoauthorisedstructuralchangeshavebeenmade.
•Thedevicehasbeenusedinaccordancewithitsintendeduseasperusermanual.
•Damageisnotaresultofimproperlymadeelectricalsystemoratmosphericphenomena.
•Themanufacturerisnotliablefordamagewhichoccurredasaresultofimproperuseor
mechanicaldamage.
Incaseoffailure,thedevicemustbesubmittedforrepairwithaWarrantyCard.
Defectsrevealedwithinthewarrantyperiodwillberemovedfreeofchargenolongerthan14
daysafteracceptingtheproductforrepair.Warrantyandpost-warrantyrepairsareperformed
bythemanufactureri.e.FAKROPP.Sp.zo.o.
Qualitycertificate:
Device
Model...........................................................................
SerialNumber.............................................................
Seller...........................................................................
Address........................................................................
Purchasedate...............................................................
......................................................................................
Signature(stamp)ofinstallingperson
Warranty
FAKROSp.zo.o
Ul.Węgierska144A
33-300NowySącz
Polska
www.fakro.com
tel.+48184440444
fax.+48184440333
©2016FAKRO®21.01.16NC837-GB
Warranty
7
FTP-V(FTU-V)Z-W
ave
2
FTP-V(FTU-V)Z-W
ave
DearSir/Madam!ThankyouforpurchasingtheproductfromFAKROCompany.Wedohopethat
itwillmeetyourexpectations.Toensureappropriatefunctioningoftheproduct,pleaseperuse
thisUserManual.
Safetyrequirements......................................................................................................................................2
Windowuserequirements............................................................................................................................3
Productdescription.......................................................................................................................................4
Packagecontent..............................................................................................................................4
Technicalspecification....................................................................................................................4
ElectricZ-Wavewindow.................................................................................................................5
DeclarationsoftheManufacturer...............................................................................................................6
DeclarationofConformity..............................................................................................................6
DeclarationofPerformance............................................................................................................7
Warranty........................................................................................................................................................8
Contents
Safetyrequirements
WheninstallingFTP-V,FTU-VZ-Wavewindowitisnecessarytoobservethefollowingrecommendations:
•Safetyrequirementsshouldbeparticularlyrespected.Theuseofelectricmechanicalactuatorinstalledinordertooperatethewindow
createsariskofinjury.Althoughthemechanismoftheactuatorisequippedwithanoverloadswitch,forcespresenttherearestrong
enoughtocausephysicalinjuries.Whenclosingthewindow,theactuatorexertstheforceof250N(app.25kg)!
•IftheZ-Wavewindowiseasilyavailablee.g.window'sbottomedgeislowerthan2.50mfromthefloor,specialprecautionsshouldbe
takeninordernottoallowrisingofhealthrisk.
•Thisequipmentisnotdesignedforusebypeople(includingchildren)withlimitedphysical,sensoryormentalability,orbypeoplethat
donothaveexperienceorknowledgeofequipment,unlessitisdoneundersupervisionoraccordingtoequipmentusageinstructions,
whichareprovidedbythepersonresponsibleforsafety.Donotallowchildrentoplaywithequipment.
•Afterunpacking,checkthewindowelementsforanysignsofmechanicaldamage.
•Installationshouldbeperformedbyaqualifiedpersoninaccordancewiththemanufacturerinstructions.
•Beforeconnectingthewindow,makesurethatthepowervoltagecorrespondswithvoltagespecifiedonthedataplate.
•Plasticcontainersusedforpackingshouldbestoredoutofchildrenreachastheymaybeapotentialsourceofdanger.
•Childrenarenotallowedtoplaywithcontrollers,controllersshouldbestoredoutoftheirreach.
•Thewindowshouldbeusedaccordingtoitsintendeddesign.TheFAKROCompanyshallnotberesponsibleforanyconsequencesbeing
theresultofimproperwindowuse.
•Anyactivitiesrelatingtocleaning,adjustmentordismantlingelectricpartsofthewindowshouldbeprecededwithdisconnectingthe
powersupply.
•Electricpartscannotbewashedusingsolvent-basedsubstancesoropenstreamofwater(donotimmerseinwater).
•Anyrepairsofthewindowshouldbycarriedoutbyserviceauthorisedbythemanufacturer.
•Electricwiressupplyingelectricitytothepowersourcemusthavesuitablearea(2x1mm2).Permissiblecablelengthforthementioned
areais30m
Safetyrequirements
3
FTP-V(FTU-V)Z-W
ave
Windowuserequirements
DescriptionfortheusermanualofFTP-VZ-Wave,FTU-VZ-WaveNC429
1.Topreventcondensationofwatervapouronthewindowduringthewinter,itisnecessarytomakeproperlyliningof
thewindowandplacesourceofheatdirectlyunderthewindow.
2.Byusingtheairinlet,automaticairexchangewithsurroundingsispossibleundertheinfluenceofthepressure
difference.Itispossibleonconditionthatthegravitationalventilationintheroomworksproperly.Manualregulationof
theairinletopeningispossible.
3.Operatingthewindowbymeansofactuatorhelpstoincreaseventilationoftheroom.
4.Incaseofroomswhereventilationthroughventilationwiresdoesnotworkproperly,itisnecessarytoventilatethe
roombycompleteopeningofthewindow.
5.Byturningthehandlethrough90degrees,thewindowisunlockedandmanualrotationofthesashthrough180
degreesispossible.Whenclosingthewindow,itisnecessarytopayspecialattentionthatbeforelockingthehandle,the
windowsashispressedstrongenough,soasnottodamagethechain'scatch.
6.Duetoappropriatelock(p.6,NC429)itispossibletocleansafelytheexternalsideofthewindowglazingunit.
7.Inordertoenjoythelongestpossiblefailurefreeuseofthewindow,periodicpreventivemaintenanceworksare
recommended.
Forappropriateworkoftherainsensor–cleaningitssurface;
Removingleavesandotherdirtfromflashingatleastonceayearinordertoensureproperflowofrainwater;
Inareaswithheavysnowfalls,precipitationlyingforalongtimeshouldberemoved.Thishelpstoreducedangerof
freezingofmeltingsnowonthewindow'sbottomelements.
8.Periodiclubricationofhingesfortheirproperworkisrecommended.
9.Incaseofwoodenwindowscoatedwithecological,clearacryliclacquer,dependingonexploitation,repaintingis
recommendedevery3-5years.
10.Actuatorisfactoryprogrammedonthefirstchannelandonthefirstgroupofbuttonsontheremotecontrol.The
ZWP10remotecontrolcommunicateswiththewindowbyusingradiowaves.Itispossibletochangetheprogrammed
channel.Todothis,refertotheusermanualofZWP10(NC851)remotecontrol.
11.PressappropriatebuttontooperateFTP-VZ-Wavewindow.
12.Pressappropriatebuttontooperateexternalaccessory:ARZZ-WaverollershutterorAMZZ-Waveawningblind.
13.Pressappropriatebuttontooperateinternalaccessory:ARFZ-WaveorARPZ-WaverollershutterorAJPZ-Wave
Venetianblind.
14.InordertoconnectARZZ-WaveexternalrollershutterorAMZZ-Waveexternalawningblind,unscrewtop
trapezoidcoverofthewindow.Thereisalsoplug-insockettoconnecttherainsensor.
15.IntheZ-Wavewindow,wires(15VDC)arerunintheframeenablingsupplyofelectricinternalaccessories:ARF
Z-Wave,ARPZ-WaveorAJPZ-Wave.
16.Sampleconfigurationof4windowsFTP-V,FTU-VZ-Wave.TheZWP10remotecontrol(ZWK10keyboard)closes
oropenfourwindowssimultaneously.TheZWDwindsensorconnectedtotheZWMPweathermoduleclosesthe
windowifstronggustsofwindappear.TheFTP-V,FTU-VZ-Wavewindowisequippedwiththerainsensoras
standard.
17.Inwindowswithwidthof78cmandmore,powersupplyispositionedinsidethewindowframewithactuatorunder
plasticplate.
18.Inwindowswiththesmallerwidthorequalto66cm,powersupplyispositionedoutsidethewindow.
19.Controlpanelofthewindowissituatedinthecoveroftheactuator.
20.SampleelectricalconnectionofthreeFTP-VZ-Wavewindowsinahouse/flat.TheFTP-VZ-Wavewindowis
installedinallthreerooms.TheZWMPweathermoduleisinstalledinoneofrooms.
Forwindowsandthemodule,230VACcurrentsupplyisbrought.TheZWDwindsensorisconnectedtotheZWMP
weathermodule.RainsensorsarealreadyfactoryinstalledineveryFTP-VZ-Wavewindow.
TheZWKkeyboardisprogrammedineveryroomallowingcontrolofthewindowaswellasaccessoriesinstalledon
thiswindow.Theadvantageofthekeyboardisthatitisfixedtothewallandallowsoperationofwindowsevenincase
oflosingremotecontrolorrunningdownitsbatteries.Remotecontrolforwindowsandaccessoriesoperationinorder
toimproveuser'scomfortisineveryroom.Additionally,atexitdoor,keyboardforsimultaneouswindowsoperationis
placed.Itisconvenientfunction,usedespeciallywhenleavingthehouse,iftheuserwantstocloseallwindows
simultaneouslyorwhenenteringthehouse,iftheuserwantstoopenallwindowssimultaneously.
6
FTP-V(FTU-V)Z-W
ave
DeclarationsoftheManufacturer
DeclarationofConformity
�������������� �������
�������������������������������������
�������������� � ��������������������������������������� ������
�� !"����#!"�$!��%��
������ &���'��(����������)����&�'��� *�+,,�-�,.-//0��������%��� '���'�'�������� &��'�����
� &���1����23�
������ &���'��(����������)����&�'��� *��444-5-//0��������%��� '���'�'������ ���%������'��*�'���
����� &&�'����� '��)��&�'���'��&��������� �'��� '� *�������� '* �&��23
������ &���'��(����������)����&�'��� *�+,,6-45-//0��������%��� '���'�'������������)��&�'��
�����'���* ������(����'�������'�% ��������&���3
������1��'�&�'�*����������� ���'��� ����& '��������'������ 7!/7�8,,++,!+�� 7!/7�8,��.4!8��
7!/7�55,��!��� 7!/7�55,��!+�� 7!/7�6,885!+!49�� 7!/7�6,885!�3
������ !"����#!"�$!��%������ '��������� �1����&����'���������'�1���'�� ������� �����
'�2��*�����'�������� '���* �&������ ���'��� ��'�������� '��'��������'������� '���
5
FTP-V(FTU-V)Z-W
ave 7
BelowthereispresentedgeneralviewoftheZ-Wavewindow.Thepowersupplywithconnectedactuatorare
positionedundertheplasticplateu.Electricwiresarerunfromthepowersupplytoplaceofinternalaccessory
connectionw
andtoplaceofexternalaccessoryconnectionx.Theactuatorisequippedwithbidirectionalmoduleof
radiocommunication.Forcommunication,Z-WaveprotocolusesEU868,42MHzwavefrequency.Theactuatoris
equippedwiththechainv
characterizedbythemaximumextensionof24cm.Thechainfeaturesspecialendingthat
allowstoblockitinthehandle.TheZWP10remotecontrolisusedtooperatetheZ-Wavewindow.Incaseofchangeof
Z-Wavenetworkconfiguration,seeprogramminginstructionsofZWP10remotecontrol.
ProgrammingofaccessoriesconnectedtoZ-Wavewindowisinprogramminginstructionsattachedforparticulardevice.
TheZ-Wavewindowisequippedasstandardwiththerainsensorandwhenthefirstraindropsappear,itsendscommand
“close”toactuator,whichclosesthewindow.Installtherainsensory
inaccordancewiththefittinginstructionsofthe
window.Iftherollershutterorawningblindistobeinstalledonthewindow,attachtherainsensorontherollershutter
orawningblind.Afterinstallation,connectthewindowto230VAC,cable3x1mm2z.
Productdescription
ElectricZ-Wavewindow
WARNING!Dangerofcrashing.Whenclosingthewindow,theactuator
exertstheforceof250N(app.25kg)!
WARNING!If
waterappears
on
the
rain
sensor,
the
actuator
automaticallyclosesthewindow!
WARNING!Dangerofelectricshock!
uPlasticplate
vChainactuator
wPlaceofinternalaccessoryconnection
xPlaceofexternalaccessoryconnection
yRainsensor
zPowercable3x1,00mm2
{Controlpanelwithavailablebuttons:P
programmingbuttonandmanualcontrolbutton.
4
FTP-V(FTU-V)Z-W
ave
Packagecontent
Productdescription
uTheFTP-V(FTU-V)Z-Wavewindowisequippedwiththechainactuator,60Wpowersupplyandrainsensor.
vInstallationsetformountingthewindowintheroof.
wTheZWP10remotecontrolenablesoperationofthewindowdirectlyafterconnectionto230V(channel[1],first
groupofbuttonsofmovement).
xFitting,programmingandusageinstructionsoftheFTP-V(FTU-V)windowandtheZWP10remotecontrol.
InordertousetheremotecontrolfromthesettooperateotherZ-WaveproductsorchangeZ-
Wavenetwork
settingspleaseuseNC851programmingandusageinstructionsoftheremote
control.
Technicalspecification
Window
actuatoris
factory
programmedto
theremote
controlonchannelNo.[1]to
first