Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

Date post: 30-May-2018
Category:
Upload: e-comfortusa
View: 219 times
Download: 0 times
Share this document with a friend

of 8

Transcript
  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    1/8

    Up to 16.5 SEER*

    Mix & Match Multi-Zone SystemsIndoor Units (Wall Mounted): ASU9RMLQ, ASU12RMLQ, ASU18RMLQ

    Indoor Units (Concealed Ceiling): ARU9RML, ARU12RML, ARU18RMLIndoor Units (Cassette): AUU9RML, AUU12RML, AUU18RML Available 3/09

    Outdoor Units: AOU24RML1, AOU36RML1

    *SEER rating depends on combination of indoor units.

    **Available on wall mounted evaporator only.

    ^ Not available on concealed ceiling model.

    Standard Features

    Plasma Filter** Sleep Timer

    24 Hour Timer

    Auto Louver: Up/ Down** Coil Dry Mode**

    Auto Restart Quiet Mode^

    Dry Mode

    Cold Prevention

    Full Function Wired Remote Remote Control Thermo Sensor

    Child Lock Capable

    Optional Remote (for wall mounted units)Concealed ceiling and cassette type units include a wired remote control sta

    Multi-Zone SEER, HSPF

    Wall CassetteConcealed

    CeilingMixed

    Dual Zone SEER 16.5 16.5 15.0 15.75

    Dual Zone HSPF 9.0 9.4 8.6 8.8

    Tri/Quad Zone SEER 15.0 16 14.0 14.5

    Tri/Quad Zone HSPF 9.0 9.4 8.6 8.8

    Applications

    Contractors can select either a 24 or 36,000 BTU

    outdoor unit combined with 9,000, 12,000 or 18,000

    BTU wall mounted, compact cassette or concealed

    ceiling type indoor units. Create 110 different systems

    with only 11 components. Mix-and-match flexibility of

    evaporator type and capacity allows you to choose theindoor unit that best fits the application, whether it be

    hidden or showcased. These systems are ideal for

    nursing homes, doctor's offices, condominiums,

    apartments and residences - any place where individual

    cooling or heating is needed. UTB-UU(Concealed Ce

    UTY-RNBY(Compact Cas

    22.5

    22.5

    Return Air-intake(Concealed Ceiling Model)

    Air intake direction can be selected

    to match the installation site.

    Back

    Bottom

    Easy Installation(Cassette Model)

    Fits into a standard ceiling tile*.

    I.A.Q. Plasma Filter(Wall Mounted Model)

    High performance electronic air cleaner

    removes dust and odor, improving indoor

    air quality.

    Clean Air

    Dirty Air

    Collects Dust

    Electrostatic

    Filter

    Ionization Filter

    Ionization Pins

    *Dimensions of outer grille are 27-9/16 x

    27-9/16 and may overlap adjacent tiles.

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    2/82

    Multi-Zone Indoor Units

    Model ASU9RMLQ AUU9RML ARU9RML ASU12RMLQ AUU12RML ARU12RML ASU18RMLQ AUU18RML ARU18RML

    Type WALL CASSETTECONCEALED

    CEILINGWALL CASSETTE

    CONCEALED

    CEILINGWALL CASSETTE

    CONCEALED

    CEILING

    Standard Remote WIRELESSWIRED

    (UTY-RNBYU)

    WIRED

    (UTB-UUB)WIRELESS

    WIRED

    (UTY-RNBYU)

    WIRED

    (UTB-UUB)WIRELESS

    WIRED

    (UTY-RNBYU)

    WIRED

    (UTB-UUB)

    Optional Remote UTY-RNBYU^ - UTY-RNBYU^ UTY-RNBYU^ - UTY-RNBYU^ UTY-RNBYU^ - UTY-RNBYU^

    Min/Nom/Max

    Clg BTU/h 5.1k/9.5k/11.3k 5.1k/9.5k/11.3k 5.1k/9.5k/11.3k 5.1k/12k/13.6k 5.1k/12k/13.6k 5.1k/12k/13.6k 6.1k/17.8k/19k 6.1k/17.8k/19k 6.1k/17.8k/19

    Min/Nom/Max

    Htg BTU/h5.1k/11k/13k 5.1k/11k/13k 5.1k/11k/13k 5.1k/14k/15.4k 5.1k/14k/15.4k 5.1k/14k/15.4k 6.1k/20.5k/23k 6.1k/20.5k/23k 6.1k/20.5k/23

    C.F.M.: Hi/Med/

    Lo/Quiet

    Static Pressure

    (in.WG)

    312/271/

    224/194

    318/288/

    259/230

    294/241/

    218/-

    (.0/.0/.0)

    365/318/

    265/224

    359/312/

    277/241

    412/377/

    324/-

    (.0/.0/.0)

    377/347/

    294/253441/359/

    306/241

    494/412/

    377/-

    (.0/.0/.0)

    C.F.M.: Hi/Med/Lo

    Static Pressure

    (in.WG)

    - -250/210/195

    (.16/.10/.08)- -

    305/280/250

    (.16/.13/.10)- -

    380/325/290

    (.16/.14/.12)

    Noise level dB(A):

    Hi/Med/Lo/Quiet

    37/33/

    27/24

    34/32/

    29/27

    39/35/

    32/-

    42/38/

    32/27

    37/33/

    31/28

    36/34/

    31/-

    44/42/

    38/33

    44/40/

    37/30

    40/36/

    34/-

    Fan Speeds Stage 4 + Auto 4 + Auto 3 + Auto 4 + Auto 4 + Auto 3 + Auto 4 + Auto 4 + Auto 3 + Auto

    Air

    Direction

    Horizontal Manual - - Manual - - Manual - -

    Vertical Automatic Automatic - Automatic Automatic - Automatic Automatic -

    Air Filter Washable Washable Washable Washable Washable Washable Washable Washable Washable

    Plasma Filter Yes No No Yes No No Yes No No

    Weight lb (kg) 20 (9.5) 33 (1.5) 40 (18) 20 (9.5) 33 (1.5) 55 (25) 20 (9.5) 33 (1.5) 55 (25)

    HxWxD

    in (mm)

    11-5/32 x

    31-3/32 x

    9-1/16

    (283x790x230)

    9-21/32 x

    22-14/32 x

    22-14/32

    (245x570x570)

    8-17/32 x

    26-3/32 x

    23-7/16

    (217x663x595)

    11-5/32 x

    31-3/32 x

    9-1/16

    (283x790x230)

    9-21/32 x

    22-14/32 x

    22-14/32

    (245x570x570)

    8-17/32 x

    37-17/32 x

    23-7/16

    (217x953x595)

    11-5/32 x

    31-3/32 x

    9-1/16

    (283x790x230)

    9-21/32 x

    22-14/32 x

    22-14/32

    (245x570x570)

    8-17/32 x

    37-17/32 x

    23-7/16

    (217x953x595

    Connection FLARE FLARE FLARE FLARE FLARE FLARE FLARE FLARE FLARE

    Suction+ 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2

    Discharge 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4

    Dual-Zone Combinations

    Type of

    Indoor Unit

    Total

    Min/Nom/Max

    Clg BTU/h

    Total

    Min/Nom/Max

    Htg BTU/h

    Low Clg

    17F

    BTU/h

    SEER HSPFEER

    Clg/Htg

    MoistureRemova

    l Pt./h

    (l/h)

    Rec.Fuse

    Size

    (A)

    TotalMax.

    Lgth Ft.

    (m)

    Max

    Lgth

    Ea.

    Ft.

    (m)

    Max.

    Vertical

    Diff. Ft.

    (m)

    CurrentRated/

    Max (A):

    Clg

    CurrentRated/

    Max (A):

    Htg

    Power

    Use

    Rated/

    Max (kw):

    Clg

    Power

    Use

    Rated/

    Max (kw

    Htg

    9+9

    Wall 11k/19k/22.6k 11k/22k/26k *13200 16.5 9 12.2/12.53.4

    (1.6)20 98 82 33 6.8/8.3 7.7/9.2 1.56/1.9 1.76/2.1

    Cassette 11k/18.2k/22.6k 11k/22k/26k *13200 16.5 9.4 11.3/11.23.8

    (1.8)20 98 82 33 7.0/9.0 8.5/10.7 1.6/2.05 1.95/2.4

    Concealed

    Ceiling11k/17.6k/22.6k 11k/22k/26k *13200 15 8.6 10.6/10.3

    3.8

    (1.8)20 98 82 33 7.2/9.0 9.3/10.7 1.65/2.05 2.13/2.4

    **Mixed 11k/19k/22.6k 11k/22k/26k *13200 15.75 8.8 12.2/12.53.4

    (1.6)20 98 82 33 7.2/9.0 9.3/10.7 1.65/2.05 2.13/2.4

    9+12

    Wall 11k/21.4k/26k 11k/25k/32k *15000 16.5 9 11.1/12.34.0

    (1.9)20 98 82 33 8.4/11.4 8.9/12 1.92/2.6 2.04/2.7

    Cassette 11k/20.8k/26k 11k/24.7k/32k *15000 16.5 9.4 10.6/10.94.4

    (2.1)

    20 98 82 33 8.6/11.8 9.8/14 1.96/2.7 2.25/3.2

    Concealed

    Ceiling11k/20.2k/26k 11k/24.4k/32k *15000 15 8.6 10.2/9.9

    4.4

    (2.1)20 98 82 33 8.7/11.8 10.8/14 1.99/2.7 2.46/3.2

    **Mixed 11k/20.2k/26k 11k/24.4k/32k *15000 15.75 8.8 11.1/12.34.0

    (1.9)20 98 82 33 8.7/11.8 10.8/14 1.99/2.7 2.46/3.2

    12+12

    Wall 11k/24k/27.6k 11k/28k/33k 16600 16.5 9 10.4/11.94.6

    (2.2)20 98 82 33 10.1/12 10.3/12 2.3/2.75 2.35/2.7

    Cassette 11k/23.4k/27.6k 11k/27.6k/33k 16600 16.5 9.4 9.95/8.95

    (2.4)20 98 82 33 10.3/13.5 11.1/14 2.35/3.1 2.53/3.2

    Concealed

    Ceiling11k/22.8k/27.6k 11k/27.2k/33k 16600 15 8.6 9.5/9.9

    5

    (2.4)20 98 82 33 10.5/13.5 12/14 2.4/3.1 2.74/3.2

    **Mixed 11k/22.8k/27.6k 11k/27.6k/33k 16600 15.75 8.8 9.5/9.94.6

    (2.2)20 98 82 33 10.5/13.5 12/14 2.4/3.1 2.74/3.2

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria.

    Ask your contractor for details or visit www.energystar.gov. The 9+9 wall mounted dual zone combination is the only model that is ENERGY STAR Qualified from the multi-zone line.

    *Low Heating Output capacity is calculated data, as not all combinations have been tested.

    ** Mixed calculation is based upon the statistical average of ducted and wall mounted indoor units.

    ^Thermo-Sensor button and Energy Save button non-functional with this indoor model.+For quad zone connection there is an adapter provided in order to connect the 3/8 lineset to the 1/2 valve on port A.

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    3/8

    *Low Heating Output capacity is calculated data, as not all combinations have been tested.

    Tri and Quad-Zone Combinations

    Type of

    Indoor

    Unit

    Total

    Min/Nom/Max

    Clg BTU/h

    Total

    Min/Nom/Max

    Htg BTU/h

    Low Clg

    17F

    BTU/h

    SEER HSPFEER

    Clg/Htg

    Moisture

    Remova

    l Pt./h

    (l/h)

    Rec.

    Fuse

    Size

    (A)

    Total

    Max.

    Lgth Ft.

    (m)

    Max

    Lgth

    Ea. Ft.

    (m)

    Max.

    Vertical

    Diff. Ft.

    (m)

    Current

    Rated/

    Max (A):

    Clg

    Current

    Rated/

    Max (A):

    Htg

    Power

    Use

    Rated/

    Max (kw):

    Clg

    Po

    U

    Ra

    Max

    H

    9+9+9

    Wall 11k/27.6k/33k 11k/33k/40.2k *19800 15 9 10/11.15.1

    (2.4)30 230 82 49 12/16.4 13/16.6 2.75/3.74 2.96

    Cassette 11k/27k/33k 11k/33k/40.2k *19800 16 9.4 9.5/10.25.7

    (2.7)30 230 82 49 12.2/16.414.1/18.8 2.8/3.74 3.23

    Concealed

    Ceiling

    11k/26.6k/33k 11k/33k/40.2k *19800 14 8.6 9.3/9.45.7

    (2.7)

    30 230 82 49 12.4/16.415.3/18.8 2.85/3.74 3.5

    **Mixed 11k/26.6k/33k 11k/33k/40.2k *19800 14.5 8.8 9.3/9.45.1

    (2.4)30 230 82 49 12.4/16.415.3/18.8 2.85/3.74 3.5

    9+9+12

    Wall 11k/30.4k/33.8k 11k/35.4k/40.6k *21240 15 9 9.2/11.45.7

    (2.7)30 230 82 49 14.4/18 13.5/18 3.3/4.1 3.1

    Cassette 11k/29.8k/33.8k11k/35.4k/40.6k *21240 16 9.4 8.85/8.06.3

    (3)30 230 82 49 14.6/19.115.3/18.8 3.35/4.38 3.5

    Concealed

    Ceiling11k/29.2k/33.8k11k/35.4k/40.6k *21240 14 8.6 8.6/9.1

    6.3

    (3)30 230 82 49 14.8/19.1 17/18.8 3.4/4.38 3.9

    **Mixed 11k/29.2k/33.8k11k/35.4k/40.6k *21240 14.5 8.8 8.6/9.15.7

    (2.7)30 230 82 49 14.8/19.1 17/18.8 3.4/4.38 3.9

    9+12+12

    Wall 11k/33k/34.6k 11k/37k/41k *21900 15 9 8.8/11.26.3

    (3)30 230 82 49 16.4/18 14.5/18 3.75/4.1 3.3

    Cassette 11k/32.2k/34.6k 11k/36.6k/41k *21900 16 9.4 8.4/9.76.9

    (3.3) 30 230 82 49 16.7/19.7 16.4/18.8 3.83/4.38 3.75

    Concealed

    Ceiling11k/31.4k/34.6k 11k/36.2k/41k *21900 14 8.6 8.1/8.6

    6.9

    (3.3)30 230 82 49 17/19.1 18.3/18.8 3.9/4.38 4.2

    **Mixed 11k/31.4k/34.6k 11k/36.2k/41k *21900 14.5 8.8 8.1/8.66.3

    (3)30 230 82 49 17/19.1 18.3/18.8 3.9/4.38 4.2

    12+12+12

    Wall 11k/35k/35.6k 11k/37.2k/42k *22080 15 9 8.8/11.36.9

    (3.3)30 230 82 49 17.5/18 14.5/16.6 4/4.1 3.3

    Cassette 11k/33.8k/35.6k 11k/36.4k/42k *22080 16 9.4 8.25/107.5

    (3.6)30 230 82 49 17.8/19.1 16/18.8 4.08/4.38 3.65

    Concealed

    Ceiling11k/32.8k/35.6k 11k/36.2k/42k *22080 14 8.6 7.9/9.1

    7.5

    (3.6)30 230 82 49 18.1/19.117.5/18.8 4.15/4.38 4/4

    **Mixed 11k/32.8k/35.6k 11k/36.2k/42k *22080 14.5 8.8 7.9/9.16.9

    (3.3)30 230 82 49 18.1/19.117.5/18.8 4.15/4.38 4/4

    9+9+18

    Wall 11k/35.2k/36k 11k/37.2k/42k *22200 15 9 8.8/11.38.3

    (3.9)30 230 82 49 17.5/18 14.5/16.6 4/4.1 3.3

    Cassette 11k/34.2k/36k 11k/37k/42k *22200 16 9.4 8.35/10.67.2

    (3.4)30 230 82 49 17.8/19.1 15.2/18.8 4.08/4.38 3.48

    Concealed

    Ceiling11k/33.2k/36k 11k/36.8k/42k *22200 14 8.6 8.0/10.1

    7.2

    (3.4)30 230 82 49 18.1/19.1 16/18.8 4.15/4.38 3.65

    **Mixed 11k/33.2k/36k 11k/36.8k/42k *22200 14.5 8.8 8.0/10.17.2

    (3.4)30 230 82 49 18.1/19.1 16/18.8 4.15/4.38 3.65

    9+9+9+9

    Wall 11k/35.2k/36k 11k/36.4k/42k 22000 15 9 8.8/12.16.8

    (3.2)30 230 82 49 17.5/18 13.1/16.2 4/4.1 3.0

    Cassette 11k/34.4k/36k 11k/36.4k/42k 22000 16 9.4 8.45/11.37.6

    (3.6)30 230 82 49 17.8/19.1 14.0/16.8 4.07/4.38 3.21

    Concealed

    Ceiling11k/33.8k/36k 11k/36.4k/42k 22000 14 8.6 8.1/10.6

    7.6

    (3.6)30 230 82 49 18.1/19.1 15.1/16.8 4.15/4.38 3.45

    **Mixed 11k/33.8k/36k 11k/36.4k/42k 22000 14.5 8.8 8.1/10.66.8

    (3.2)30 230 82 49 18.1/19.1 15.1/16.8 4.15/4.38 3.45

    OUTDOOR UNITS

    HxWxD in (mm)

    Operating RangeWeight

    lb (kg)

    Connection

    Type

    Noise Level

    dB(A):

    Clg/Htg

    Outdoor Fan

    Airflow Rate

    CFM (Clg/Htg)

    Rec.

    Fuse

    Size

    Voltage(V)/

    Frequency(Hz)/

    Phase

    Refrig

    Cooling Heating

    AOU24RML132-7/8 x 35-7/16 x 13

    (835x900x330)

    32 ~ 115 (F)

    0 ~46 (C)

    14 ~ 75 (F)

    -10 ~24 (C)

    136 (62) FLARE 50/51 1,883/1,883 20 208~230/60/1 410

    AOU36RML1 149 (68) FLARE 51/53 2,119/2237 30 208~230/60/1 410A

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    4/8

    This guide shows examples of typical duct layouts and sizing that can be used with Fujitsu Concealed Ceiling Type Units

    Static pressure loss calculations and duct fitting types are based on ACCA

    Residential Duct Systems Manual D (Air Conditioning Contractors of America).

    Layouts are designed to limit duct system static pressure loss to 0.16 in. w.c.

    or less (including fittings and filters).

    Available CFM at the maximum static pressure loss of 0.16 in. w.c. is listed in

    the Duct Sizing Chart by model.

    To use the Duct Sizing Chart:

    1. Locate the column with the desired Model Number and Plan Layout (Plan A, Plan B, Plan C).

    2. Fitting number in the Ref # column (ex. Ref # 2) corresponds to the number on the duct layouts below.

    3. Fittings used in your installation should be as shown in the Duct Fittings section on Page 6.

    4. Fitting types (ex. 4-AB), found on Page 6 are listed in each column on Duct Sizing Chart in Rows 2 - 6.

    5. The duct section letter (ex. A) in the Ref # column corresponds to the letter on the duct layout below.

    6. Duct sizes and allowable lengths are listed in the Rows A - E for each Model and Plan.

    7. The duct size should be as indicated in the chart.

    8. The duct length should not exceed the length listed in the chart.9. Reducing duct sizes or increasing duct lengths from chart values may result in lack of airflow and capacity.

    Transitions from rectangular unit inlet and outlet to round duct (12C & 12L) are based on a maximum equivalent length (EL) of 20 for

    the return (Diverging) and 10 for the supply (Converging). Transitions are available as an accessory from Fujitsu. See Page 6.

    The duct layouts below include a single return air filter grille. Examples are based on using 1" fiberglass filters (rated at .07 in. w.c.

    pressure loss @ 300 FPM). Filter face velocities were selected to limit the static pressure loss. See the Duct Sizing Chart for filter

    velocities for various models. Filter grilles should be selected with a filter face area equivalent to the filter sizes listed in the chart. It

    may be possible to use 1" pleated filters if the face velocity is reduced to 150 FPM or less. Using the layouts below, the combined

    pressure loss of the filter and grille cannot exceed .07 in. w.c. for the ARU9 and 18 and .056 in. w.c. for the ARU12 at design CFM.

    Plan A

    Plan B

    Plan C

    4

    4

    B

    6

    1

    5

    A

    2

    2

    A 3B

    6

    1

    5

    4

    C

    4C

    E

    6

    1

    47

    7

    5

    D

    2

    DUCT SIZING GUIDE

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    5/8

    DUCT SIZING CHART

    Ref # Plan A Plan B Plan C Plan A Plan B Plan C Plan B Plan

    1

    Model Number ARU9RML ARU9RML ARU9RML ARU12RML ARU12RML ARU12RML ARU18RML ARU18

    CFM 250 250 250 305 305 305 380 380

    SP, in. W.C. 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.1

    Inlet, inches 7x21 7x21 7x21 7x32 7x32 7x32 7x32 7x3

    Filter Size, inches 8x20x1 8x20x1 8x20x1 8x30x1 8x30x1 8x30x1 8x30x1 8x30

    Filter Velocity, FPM 225 225 225 183 183 183 227 227

    Filter SP loss, in. W.C. 0.040 0.040 0.040 0.026 0.026 0.026 0.040 0.04

    Discharge, inches 6x15-3/4 6x15-3/4 6x15-3/4 6x24 6x24 6x24 6x24 6x2

    2Return Filter Grille, CFM/SP 250/0.07 250/0.07 250/0.07 305/.056 305/.056 305/.056 380/.07 380/.

    Return Boot (6-G) .010 (6-G) .010 (6-F) .009 (6-G) .015 (6-G) .015 (6-F) .013 (6-G) .012 (6-F) .

    3 Y Branch 0.003 0.005 0.004

    4Supply Register, CFM/SP 250/0.03 125/0.03 250/0.03 305/0.03 150/0.03 305/0.03 190/0.03 380/0

    Supply Boot/Elbow (4-AB) .019 (4-AD) .012 (4-AO) .008 (4-Y) .030 (4-AD) .019 (4-AO) .017 (4-AB) .013 (4-AO)

    5 Return Transition (12-C) .008 (12-C) .008 (12-F) .008 (12-C) .011 (12-C) .011 (12-F) .011 (12-C) .008

    6 Supply Transition (12-L) .004 (12-L) .004 (12-L) .006 (12-L) .006 (12-O) .006 (12-L) .004

    7 90 deg. Elbow, w/Vanes 0.008 0.011 0.00

    A

    Return Flex Duct Size 10 10 10 10 12

    Length, Ft 5/8 5/8 5/7 5/9 5/6

    SP, in. W.C. 0.003 0.003 0.004 0.004 0.002

    B

    Supply Flex Duct Size 10 10 10 10 12

    Length, Ft 15/20 5 10/15 5 5

    SP, in. W.C. 0.008 0.003 0.008 0.004 0.002

    C

    Supply Flex Duct Size 8 8 10

    Length, Ft 10/15 10/15 15/21

    SP, in. W.C. 0.006 0.008 0.006

    D

    Rect. Return Duct Size 14x6 14x6 32x

    Length, Ft 10 10 10

    SP, in. W.C. 0.004 0.006 0.00

    E

    Rect. Supply Duct Size 14x6 14x6 24x

    Length, Ft. 10 10 10

    SP, in. W.C. 0.004 0.006 0.00

    Total Static Pressure Loss 0.152 0.149 0.141 0.160 0.158 0.156 0.151 0.15

    Notes 1 1 1 2, 3, 5 3, 5 3 1 4

    Notes:

    Static pressure calculations based on ACCA Residential Duct Systems

    Manual D.

    Fitting type designation (i.e. 4-AB) from ACCA Residential Duct Systems

    Manual D.

    Return Filter Grille includes filter static pressure loss at design velocity.

    Filters 1" fiberglass, rated .07 in. W.C. pressure loss @ 300 FPM.

    Return Filter Grille (less filter) pressure loss .03 in. W.C.

    When using duct board on plan C there is no change in allowable

    lengths. Lengths allowed when using galvanized metal ducts.

    1. Two additional 90 degree bends (flex) or elbows (rectangular)

    allowable.

    2. Supply Boot/Elbow pressure loss includes 4-Y boot plus 90

    degree elbow.

    3. Additional 90 degree bends (flex), elbows (rect.) or duct length

    will require increase in duct size.

    4. Duct length limited to 20 ft. Additional elbows/fittings not allowed.

    5. 12/10 taper reducer/increaser required when using Fujitsu Supply

    (ST) and Return (RT) Transitions.

    D

    A

    T

    A

    F

    I

    T

    T

    I

    NG

    S

    D

    U

    C

    T

    S

    E

    C

    T

    I

    O

    N

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    6/8

    TRANSITIONS (CONVERGING)

    TRANSITIONS (DIVERGING)

    ACCA EXAMPLES OF FIELD SUPPLIED FITTINGS*

    FUJITSU OFFERS TRANSITIONS

    EL Values A1/A2 A1/A2

    Slope 2 4

    1:1 20 40

    2:1 20 40

    4:1 20 30

    EL Values A1/A2 A1/A2

    Slope 2 4

    1:1 20 40

    2:1 20 40

    4:1 15 30

    EL Values A1/A2 A1/A2

    Slope 2 4

    1:1 10 10

    2:1 5 5

    4:1 5 5

    EL Values A1/A2 A1/A2

    Slope 2 4

    1:1 10 10

    2:1 5 5

    4:1 5 5

    *Duct fitting references and images from Appendix 3, ACCA Residential Duct Systems Manual D. Copyright 1995, Air Conditioning Contractors of

    America, Reprinted 2006. Used by permission.

    4-AB 4-AD 4-AO 4-Y

    EL = 90 EL = 60 EL = 40 EL = 35

    12-C 12-F

    12-L12-O

    6-F

    EL = 25 EL = 30

    These are examples of typical sheet metal fittings according to ACCA. The letters next to the fitting can be found on

    the chart on the preceding page.

    6-G

    RT-ARU9 Return

    Inlet transition:

    7 x 21 rectangular x 10 round

    ST-ARU9 Supply

    Discharge transition:

    6 x 15-3/4 rectangular x 10 round

    RT-ARU12/18 Return

    Inlet transition:

    7 x 32 rectangular x 12 round

    ST-ARU12/18 Supply

    Discharge transition:

    6 x 23-3/4 rectangular x 12 round

    Did you know?Concealed ceiling or compact cassette type indoor units

    can be networked together to work off of a single wired

    remote as long as all indoor units are the same type.

    6

    SUPPLY AIR FITTINGS RETURN AIR FITTINGS

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    7/8

    Allowable Combinations

    18,000 BTU Dual Zone Combinations

    9 9 9 9 9 9

    9 9 9 9 9 9

    21,000 BTU Dual Zone Combinations

    9 12 9 12 9 12

    9 12 9 12 9 12

    9 12 9 12 9 12

    24,000 BTU Dual Zone Combinations12 12 12 12 12 12

    12 12 12 12 12 12

    27,000 BTU Tri Zone Combinations

    9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9

    9 9 9

    30,000 BTU Tri Zone Combinations

    9 9 12 9 9 12 9 9 12

    9 9 12 9 9 12 9 9 12

    9 9 12 9 9 12 9 9 12

    9 9 12 9 9 12 9 9 12

    9 9 12 9 9 12 9 9 129 9 12 9 9 12 9 9 12

    33,000 BTU Tri Zone Combinations

    9 12 12 9 12 12 9 12 12

    9 12 12 9 12 12 9 12 12

    9 12 12 9 12 12 9 12 12

    9 12 12 9 12 12 9 12 12

    9 12 12 9 12 12 9 12 12

    9 12 12 9 12 12 9 12 12

    36,000 BTU Tri Zone Combinations

    9 9 18 9 9 18 9 9 18

    9 9 18 9 9 18 9 9 18

    9 9 18 9 9 18 9 9 18

    9 9 18 9 9 18 9 9 189 9 18 9 9 18 9 9 18

    9 9 18 9 9 18 9 9 18

    12 12 12 12 12 12 12 12 12

    12 12 12 12 12 12 12 12 12

    12 12 12 12 12 12 12 12 12

    12 12 12

    36,000 BTU Quad Zone Combinations

    9 9 9 9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9 9 9 9

    9 9 9 9 9 9 9 9 9 9 9 9

    18129 1812918129Wall Mount Cassette Duct Type

    7

    ARU9RMLARU12RML

    ARU18RML

    AUU9RML*AUU12RML*

    AUU18RML*

    AOU24RML1AOU36RML1

    ASU9RMLQASU12RMLQ

    ASU18RMLQ

    * Note: Compact Cassette Grille (Model # UTG-CCG) sold separately.

  • 8/14/2019 Fujitsu Halcyon Multi Zone Heat Pump Systems Brochure

    8/8

    Fujitsu General America, Inc.

    353 Route 46 West

    Fairfield, NJ 07004

    Toll Free: (888) 888-3424

    Local: (973) 575-0380

    Fax: (973) 836-0447

    Email: [email protected]

    www.fujitsugeneral.com

    A subsidiary of

    Fujitsu General Limited

    Distributed by:

    Printed in the USA Rev. 1/09

    The Fujitsu logo is a registered trademark of Fujitsu Limited

    The Halcyon logo and name is a trademark of Fujitsu General America, Inc

    ENERGY STAR is a registered trademark of the EPA and DOE

    Copyright 2009 Fujitsu General America, Inc

    Fujitsus products are subject to continuous improvements. Fujitsu reserves the right to modify produ

    design, specifications and information in this brochure without notice and without incurring any obligation

    Select any type of indoor unit to suit the atmosphere of your room.

    Cassette

    Concealed

    Ceiling

    Wall Mounted


Recommended