Welcome toour world of innovation:
full IP technology at the bedsideplatform independent - unlimited possibilities
Fusion-IP healthcarecommunication system apps
Issue 1 (07/2012) - 1
www. .co.ukstaticsystems
Static Systems’ IP nurse call solution forms thebasic infrastructure of the Fusion-IP healthcarecommunication system.
Currently there are almost 30 apps available toenhance the basic system in line with patientneeds and hospital culture. These includesolutions associated specifically with nursecall, such as: cardiac alarm, toilet call, bedtransfer and open drugs cupboard.
Real time location systems using ultrasoundfor unrivalled location accuracy and reportingcan also be added.
For enhanced communication both at wardlevel and away from site Fusion-IP supportsVoIP mobile telephony and smart phoneconnectivity with remote access to systemsengineering and reporting programmes.
Apps available for the Fusion-IP nurse callsystem include:
Developed and manufactured in the UK , Fusion-IP is one ofthe most advanced nurse call systems available, provided bythe leading specialist in nurse call communication. Fusion-IPoffers:
� Compliance with HTM 08-03: Bedhead Services
� Automatic prioritising of alarms to assist staff in attending to themost urgent calls first.
� ’Follow-the-light’ operation with automatic re-divert to assiststaff in quickly locating the call.
� Award winning patient hand units designed in consultationwith the RNIB, and assessed as suitable for use by peoplewith a range of disabilities.
� A silver-based, non-leaching anti-microbial to assist withinfection control is incorporated during the manufacturingprocess of hand units and equipment plates as a second line ofdefence against the spread of bacteria and fungi.
� A system operating on the principal of ‘distributed intelligence’ toguarantee a robust and dependable nurse call systemwith high integrity.
� ‘Platform independent’ technology in order to allow theconnection of past, present and future system protocols -making your system future-proof.
� Choice of purpose designed equipment housing optionsincluding horizontal and vertical bedhead services solutions.
� Improved patient care and staff efficiency.
IP at the Bed� Cardiac Alarm� Catering Call� Patient Entertainment� Speech (VoIP)� Staff Paging� Lighting Control� Bed Transfer
‘'Intelligent' Real Time Location Systems� Staff Presence� Staff Attack Alarm� Roaming Patient Call� Staff Assistance� Asset Security� Hand Hygiene Monitoring� Fall Monitoring
Systems Integration� Patient Equipment Monitor� Bed Status� Bed Exit Alert� Fire Alarm Secondary Indication� Medical Gas Alarm Monitoring� Door Entry� Toilet Call� Open Drugs Cupboard
Systems Support� SMS Text Messaging� Event Logging� Remote Access
To see our apps in use visit:www.youtube.com/user/staticsystems
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
IP integrationwww. .co.ukstaticsystems
Fusion-IP single ward
IP Nurse CallNetwork
Logger
Ethernet Switch
Site LAN
PU L L
EM
E
RGENC
Y
reset
WARD 1
Fusion-IP multiple wards
PU L L
EM
E
RGENC
Y
reset
IP Nurse CallNetwork
Logger
Ethernet Switch
WARD 3
Site LAN
PU L L
EM
E
RGENC
Y
reset
WARD 1
WARD 2
PU L L
EM
E
RGENC
Y
reset
Issue 1 (07/2012) - 2
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
IP integration continued
IP Nurse CallNetwork
Legacy NurseCall System
WARD 1
Fusion-IP with legacy connectivity
Fusion-IP with VoIP wireless telephony & remote connectivity
PU L L
EM
E
RGENC
Y
reset
IP Nurse CallNetwork
Logger
Ethernet Switch
WARD 3
Site LAN
SSG PhoneManager
VoceraServer
Access Point Messaging Server
PU L L
EM
E
RGENC
Y
reset
WARD 1
WARD 2
PU L L
EM
E
RGENC
Y
reset
PU L L
EM
E
RGENC
Y
reset
Ethernet Switch
WARD 3
Site LAN
SSG PhoneManager
VoceraServer
Access Point Messaging Server
WARD 2
PU L L
EM
E
RGENC
Y
reset
Logger
Real time location system integrationwww. .co.ukstaticsystems
Single ward with ultrasound staff presence
IP Nurse CallNetwork
Logger
Ethernet Switch
Site LAN
PU L L
EM
E
RGENC
Y
reset
WARD 1
UltrasoundRoom Monitor
Staff Transmitters
Staff Transmitters
Bedheadwith Ultrasound
Monitor
Single ward with ultrasound staff assistance & roaming patient call
IP Nurse CallNetwork
Logger
Ethernet Switch
Site LAN
PU L L
EM
E
RGENC
Y
reset
WARD 1
LocationServer
UltrasoundRoom Monitor
Bedheadwith Ultrasound
Monitor
Staff & Patient TransmittersStaff & Patient Transmitters
Issue 1 (07/2012) - 3
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
Multiple wards with staff attack (ultrasound with RF backup)
PU L L
EM
E
RGENC
Y
reset
IP nurse callnetwork
Logger
Ethernet Switch
Site LAN
PU L L
EM
E
RGENC
Y
reset
WARD 1
WARD 2
Real time location system integration continued
UltrasoundRoom Monitor
RFZone monitor
RF ZoneMonitor
LocationServer
Staff TransmittersStaff Transmitters
Nurse call
Issue 1 (07/2012) - 4
www. .co.ukstaticsystems
Our nurse call solution forms the basis of theFusion-IP system - with ‘patient-to-staff’ and‘staff-to-staff’ communication as the primaryfunction.
A patient requiring assistance presses the callbutton on the patient hand unit. This causes areassurance LED on the hand unit to illuminatealong with the staff reset push button on thebedhead unit.
Simultaneously, the call is raised on staffindicators, amber coloured over door lightsilluminate and nearby tone units sound toassist staff quickly and efficiently to the waitingpatient.
On attending the patient, staff reset the call bypressing the reset button on the bedhead unitand the system returns to its quiescent state.
If staff require further assistance an‘emergency’ call - often referred to as a ‘staffassistance’ call can be raised by pulling thered emergency pull on the patient bedheadunit.A well designed nurse call system, complying with HTM 08-03:
Bedhead Services, provides reassurance to patients and canimprove nursing efficiency. Fusion-IP is one of the mostadvanced nurse call systems available, provided by the leadingspecialist in nurse call communication.
� Automatic prioritising of calls, with ‘call-upgrade’ functionality.
� ’Follow-the-light’ operation with automatic re-divert to assiststaff in quickly locating the call.
� Award winning patient hand units designed in consultationwith the RNIB, and assessed as suitable for use by peoplewith a range of disabilities.
� Comprehensive range of ‘apps’ available for the nurse callsystem allowing facilities such as wireless call buttons, bedtransfer, VoIP telephony, smart phone connectivity, pagingand remote access to be added.
� Choice of purpose designed equipment housing optionsincluding horizontal and vertical bedhead services solutions.
� A silver-based, non-leaching anti-microbial is incorporatedduring the manufacturing process of hand units and equipmentplates as a second line of defence against the spread ofbacteria and fungi.
� Operates on the principal of ‘distributed intelligence’guaranteeing a robust and dependable nurse call systemwith high integrity.
� Uses ‘platform independent’ technology in order to allow theconnection of past, present and future system protocols -making your investment future-proof.
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
The Fusion-IP nurse call solutionprovides the basic systeminfrastructure into which all other appsare connected, as well as providing‘patient-to-staff’ and ‘staff-to-staff’communication within the hospitalenvironment.
Fusion-IP is extremely flexible, withvarious methods of wiring available toallow the system to harmoniouslyconnect with, and work alongside, ahospitals’ existing LAN or legacywiring installations.
Routers, switches, cabling andconnector plugs seamlessly integratethe system and depending on thechosen wiring topology, Fusion-IPcan provide full IP at the bed andPower-over-Ethernet (PoE).
Fusion-IP nurse call app.
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
Fusion-IP nurse call system infrastructure including staffindicators, ancillary call and indicating equipment
Nurse Call App.
Patient Hand Units
Bedhead Units
system requirements features, tone & flash patterns
Alerts: staff emergency call patient call
Flash Patterns: 0.5 seconds on, steady0.5 seconds off
Tone Pattern: 0.5 seconds at 700Hz 1 second on,0.5 seconds at 1KHz 9 seconds off
Over Door Lamp: amber
Reset Location: origin of call origin of call(e.g. bedhead) (e.g. bedhead)
system of operation
BedheadUnit
Ancillary CallUnit
Pull Cord StaffIndicator
Over DoorLight
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PULL
EM
E
RGENC
Y
RESET
PU L L
EM
E
RGENC
Y
RESET
PULL
EM
E
RGENC
Y
RESET
PULL
EM
E
RGENC
Y
RESET
PU
LL
EMERG
E
NCY
RE
SE
T
PU
LL
EMERG
E
NCY
RE
SE
T
The call is raisedat staff indicators
Over door lightsand lamp toneunits operate
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
reset
PU L L
EM
E
RGENC
Y
Calls arereset at the
bedhead unit
The reassurance LEDon the hand unit and
the staff reset push on thebedhead illuminate
Pulling the ‘red’button raises an
‘emergency’staff assistance call
A patient requiringassistance presses
the call button
Cardiac alarm
Issue 1 (07/2012) - 5
www. .co.ukstaticsystems
By incorporating the Fusion-IP cardiac alarm(or code blue) app. nurse call systems canprovide an additional level of call.
Depending on the requirement, switches aremounted at bed positions or other preferredlocations throughout the ward or department.
In the event of a cardiac arrest, a member ofstaff pulls the cardiac alarm pull. This causesa reassurance LED to illuminate on thecardiac alarm plate to assure staff that analarm has been raised.
Over door lights operating on the ‘follow-the-light’ principal illuminate, nearby tone unitssound to assist staff quickly and efficiently tothe alarm. Simultaneously, an alert tone isemitted and location details are given at localstaff indicators.
On arrival at the patient, staff reset the call byreturning the cardiac pull to its original positionand the system returns to its quiescent state.The event is logged.
It is also usual for the alarm to be received ata permanently manned central station and forthe cardiac response team to receive a pagermessage.
Providing cardiac alarm as a function of the nurse call systemsave lives. Fusion-IP is one of the most advanced nurse callsystems available, provided by the leading specialist inhealthcare communications.
� Automatic prioritising of all calls.
� ’Follow-the-light’ operation to assist the cardiac response teamin quickly locating the call.
� Uses nurse call equipment plates and system infrastructure forcost effective installation and user convenience.
� Comprehensive range of ‘apps’ available for the nurse callsystem allowing facilities such as VoIP telephony, smart phoneconnectivity and paging to be added.
� Operates on the principal of ‘distributed intelligence’guaranteeing a robust and dependable nurse call systemwith high integrity.
� HTM 08-03 compliant.
reset
PU L L
EM
E
RGENC
Y
Fusion-IP cardiac alarm (code blue) app.
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
The cardiac alarm app provides anadditional level of call alongside‘patient-to-nurse’ and ‘nurse-to-nurse’call on Fusion-IP nurse call systems.
Cardiac alarm pulls are added tonurse call bedhead plates andancillary nurse call devices, and usethe same staff indicators andinfrastructure as other nurse callfacilities.
Fusion-IP nurse call systems canconnect with, and work alongside, ahospitals’ local area network (LAN),allowing the alarm to be received at apermanently manned central stationand for the cardiac response team toreceive a pager message.
Bedhead Unit Cardiac AlarmUnit
Pull Cord StaffIndicator
Over DoorLight
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PULL
EM
E
RGENC
Y
RESET
PU L L
EM
E
RGENC
Y
RESET
PULL
EM
E
RGENC
Y
RESET
PULL
EM
E
RGENC
Y
RESET
PU
LL
EMERG
E
NCY
RE
SE
T
PU
LL
EMERG
E
NCY
RE
SE
T
Fusion-IP nurse call system infrastructure including staffindicators, ancillary call and indicating equipment
Cardiac alarm app.
Bedhead units & ancillary call units with cardiac alarmpulls
system requirements features, tone & flash patterns
Alerts: cardiac alarm (code blue)
Flash Patterns: 0.25 seconds on,0.25 seconds off
Tone Pattern: 0.25 seconds on,0.25 seconds off
Over Door Lamp: blue
Reset Location: origin of call(e.g. bedhead)
system of operation
The call is raisedat staff indicators
The reset push on thebedhead illuminatesto acknowledge the
call
Over door lightsand lamp toneunits operate
The alarm isreceived at a
permanently mannedcentral station and thecardiac response team
receive a pager message
PU L L
EM
E
RGENC
Y
reset
PU L L
EM
E
RGENC
Y
reset
The alarm isreset at the
bedhead unitby pushing
the cardiac pullA staff member requiring
assistance pullsthe cardiac alarm pull
catering call
Issue 1 (07/2012) - 6
www. .co.ukstaticsystems
In today’s efficiency driven healthcareenvironment a facility which allows a patientto contact the catering team directly is a must.
With this in mind Static Systems hasdeveloped the Fusion-IP catering call app.which utilises the existing nurse callinfrastructure.
Nurse call patient hand units with a cateringcall button are provided. To call the cateringteam the button is pressed by the patient. Thecall, together with a bed reference, is raised onan indicator designated to the catering team.The call is accepted and reset at the indicatorbefore visiting the patient to attend to theirneeds.
Alternatively, the call can be reset at thepatient’s bedhead.
As a further option, indicators can besupplemented with staff pagers, and if thenurse call system includes speech the cateringteam can speak directly with the patientbefore visiting their bedside.Adding catering call to the nurse call system is an intelligent
use of existing resources, leading to reduced pressure onnursing staff whilst assisting the catering team in delivering anefficient service - all leading to improved patient care.
� Uses existing system infrastructure for a cost-effective solution.
� Award winning patient hand units designed in consultationwith the RNIB, and assessed as suitable for use by peoplewith a range of disabilities.
� Comprehensive range of ‘apps’ available to improve the patientexperience, including: patient entertainment, bed exit alert androaming patient call.
� Operates on the principal of ‘distributed intelligence’guaranteeing a robust and dependable systemwith high integrity.
� Uses ‘platform independent’ technology in order to allow theconnection of past, present and future system protocols -making your system future-proof.
~~ ~
PU L L
EM
E
RGENC
Y
reset
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
The catering call app provides anadditional level of call on the nurse callsystem, over and above thoseprovided for patient-to-staff and staff-to-staff communication.
With the majority of installations it isonly necessary to change existingpatient hand units to onesincorporating a catering call button,and to install an additional indicator foruse by the catering team.
Where required, the system cansupport speech between the patienton the ward and mobile cateringpersonnel, as well as paging unit.
nurse call
Fusion-IP nurse call system infrastructure including staffindicators, ancillary call and indicating equipment
Catering call app.
Patient hand units with catering call button
system requirements features, tone & flash patterns
Alerts: catering call
Flash Pattern: none
Tone Pattern: user defined
Over Door Lamp: none
Reset Location: catering indicator
system of operation
Bedhead Unitwith cateringcall hand unit
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
PU
LL
EMERG
E
NCY
reset
TV
CH
i
catering call
The reassuranceLED on the
hand unit illuminatesA patient requiringassistance presses
the catering call button
The call is raisedat the catering team
indicator where itis accepted and reset
before attending the patient
~~ ~
PU L L
EM
E
RGENC
Y
reset
patient entertainment(infrared tv control)
Issue 4 (08/12)
www. .co.ukstaticsystems
Many hospitals wish to provide patiententertainment. One of the most cost effectivesolutions is to use the Fusion-IP patiententertainment app. to integrate the patienthand unit with a proprietary television usingindustry standard Infrared protocols.
With the hand unit the patient can:
� turn the television ‘on’ and ‘off’� select channels using up / down buttons� control volume� select programme information� choose TV or radio services
Patient entertainment is now recognized as a crucial part ofpatient care and an aid to recovery. However, depending onthe option chosen, it can be expensive for the hospital to installand for the patient to use. Fusion-IP offers a cost competitivesolution.
� Uses propriety televisions, allowing the hospital to purchasedirect from the manufacturer.
� Provides free-to-air digital TV and commercial radio - all at nocost to the patient.
� Utilises widely available universal infrared protocols for easeof installation, servicing and upgrade.
� The hospital is not tied into a contract and servicing can becarried out by the hospital’s own qualified personnel.
� Control buttons are incorporated into the nurse call patienthand unit, designed in consultation with the Royal NationalInstitute of Blind People (RNIB) to ensure ease of use bypeople with a wide range of disabilities.
� Removes the need for a separate TV remote control unit.
� To assist with infection control, an anti-miocrobial agent isadded during the hand unit manufacturing process, and unitscan also be cleaned using a sanitising wipe.
� Additional facilities such as ‘catering call’ and ‘lighting control’can be incorporated into the hand unit for patientconvenience and improved staff efficiency.
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
Hand unit shown is for illustrative purposesonly, refer to quotation for specific details.
Services available are subject to TVdistribution system and television supplier.
The Fusion-IP Patient Entertainment solution accepts the infrared code from propriety televisions and ‘learns’functionality in order to provide an interface between the nurse call patient hand unit and the digital television.
This application is suitable for use in both multi-bed and single bed wards.
patient entertainment (infrared tv control)
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
system requirements transmitter range and coverage
Fusion-IP or Codemlon Nurse Call System
Patient Entertainment App.
Modus Bedhead with IR Module (SM784 - Pt No. 46916)
Patient Hand Unit with TV Controls
Standard FreeView enabled TV fed by a high quality co-ax networkwith FreeView TV aerial - supplied by others
technical information
* During set-up, the SM 784 Transmitter Board in the bedhead can be setto operate in a lower power mode in order to reduce the transmitter rangein multi-bed areas.
SM 784 Transmitter PCB
Transmitter Range
High Power Mode* 15.5 metres
Carrier Frequency Range:Operating Voltage:Buttons Learned:
34 - 40 KHz24Vdc� Channel Up/Down� Volume Up/Down� TV/Radio� On/Off� Programme Information
Nurse CallBedhead Unitcomplete withSM 784 PCM
8m
15.5m(max. range)
7m
6m
5m
4m
3m
2m
1m
PatientTelevision
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
30°
2.4m
3.8m
3.2m
2.6m
2.2m
1.6m
Patient Television - ceiling mounted
Patient Television -wall mounted
Bedhead with IR TV Module
Bedhead with IR TV Module
VoIP speechwww. .co.ukstaticsystems
The VoIP speech app. enhances a Fusion-IPnurse call system with the latest speechtechnology.
A patient wishing to speak with a member ofstaff, presses the call button on the patienthand unit. The reassurance LED illuminates,the call is received at staff indicators and aspeech channel is opened by a member ofstaff.
Nurse and patient speak using hand sets, oralternatively, hands-free options are available.
At the end of their conversation the call isreset at the staff indicator.
When a call is made, over door lights and toneunits continue to operate as with a non-speechsystem to assist staff in locating the call if theywish to speak face to face with the patient.
For further efficiencies, it is possible to fullyintegrate with proprietary wireless phonesystems enabling staff to answer calls andspeak with patients as they move around theward.
Systems can also be configured to allowresetting of calls from the mobile handset -providing a truly mobile nurse call indicator.
With the use of mobile phones now common place in every daylife many patients are happy, and indeed may expect, to usethe telephone to make contact with nursing staff - leading toimproved patient care and enhanced staff efficiency.
� High quality, multiple channel speech using the leading industrySIP and RTP protocols.
� Enables staff to establish immediate contact with the patient andeliminates the need to visit the bedside in order to access theirneeds.
� Full integration with wireless phone systems.
� Choice of staff handsets, including hands-free options.
Issue 1: (07/2012) - 8
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
In line with our company policy of continuous product development,we reserve the right to change design and improve specification without prior notice.
system of operation
Fusion-IP VoIP speech app.
equipment & software requirements
Fusion-IP nurse call system infrastructure including staffindicators, ancillary call and indicating equipment
VoIP Speech App.
Patient hand unit(s) with speech
Staff mobile speech handsets (optional)
The call is raisedat staff indicators
and mobile handsets(optional) allowing
conversation to take place.
The call isreset at the
staff indicator ormobile handsetas appropriate.
PU L L
EM
E
RGENC
Y
reset
TV
CH
i
A patient requiringassistance presses
the call button
The hand unitreassurance LED and
the staff reset push on thebedhead illuminate
Staff presence
Issue 1 (07/2012) - 20
www. .co.ukstaticsystems
Staff presence is available as an optionalfacility with the Fusion-IP nurse call system.
Using ultrasound technology for improvedlocation accuracy in real time staff presence isprovided primarily as an aid to efficiency,although it can also improve patient dignityand assist in work-flow analysis.
Members of staff wear transmitters. As theymove around the transmitter sends a signalwhich is detected by monitors installedthroughout the department.
On entry to a room or bed bay, active patientcall are automatically reset by the system anda green over door light outside the roomilluminates to advise that a member of staff ispresent.
Simultaneously, the real time location of staffis shown on staff indicators and logged by thesystem.
The green over door light automatically returnsto its quiescent state as the member of staffleaves the room.
As a further benefit of nurse presence, if staffpress the call button on the bedhead when‘presence’ is registered, an intermediate ‘staffassistance’ call is activated and an ‘amberover door light illuminates alongside the greenover door light to notify other members of staff
Staff presence is provided as an aid to improved efficiency. Ithelps staff locate other members of their team, reduces thedistance staff need to travel in order to fulfill their duties andcan also improve patient dignity and assist in work-flowanalysis.� Uses ultrasound technology for unrivalled accuracy and
reliable reporting.
� The location of staff is monitored in real time with over doorlights updating automatically to indicate staff presence withina room.
� ‘Addressable’ staff transmitters for named identification ofpersonnel.
� The system automatically recognises when a call is beingraised by staff and upgrades the alert to a ‘staff assistance’call.
� Uses the nurse call infrastructure, indicators and bedheadunits, thereby reducing initial system costs and the amount ofequipment required at the nurse base and patient bedpositions.
� Staff presence transmitters can also be used to provideadditional facilities including: staff attack alarm, dooraccess control and hand hygiene monitoring.
PU L L
EM
E
RGENC
Y
reset