Brisch number 76103-390 Issue 2 09/08/02
ENGLISH *76103-390*
Weight Only Scale
FX 110 / FX 120User Instructions
Avery Berkel Limited 2001. All rights reserved.
The information contained herein is the property of Avery Berkel Limitedand is supplied without liability for errors and omissions. No part may bereproduced or used except as authorised by contract or other writtenpermission. The copyright and the foregoing restriction on reproductionand use extend to all media in which the information may be embodied.
c
Warnings
Cleaning the scale
For your protection, all mains (110V or 230V) equipment used where damp orwet conditions may occur, must be supplied from a correctly fused source andprotected by an approved RCD to BS7071 or BS7288 or IEC1008-2-2 BS EN61008:1995. IF IN DOUBT SEEK ADVICE FROM A QUALIFIEDELECTRICIAN.
To avoid the possibility of electric shock or damage to the machine, alwaysisolate from the mains power supply before carrying out any routinemaintenance.
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions,such as washing soda, should not be used especially on the display windows.Under no circumstances should you attempt to wipe the inside of the machine.
The outside of the machine may be wiped down with a clean cloth moistenedwith water containing a small amount of washing up liquid.
1
2
3
FX110
Make sure that the work surface is firm, steady and free from vibration and
draughts.
Hold the scale by the base when picking up. Do not pick up the scale by the
weigh plate or cross.
Adjust the feet if the scale is not level.
Remove parts 1- 4 before installing the machine
InstallationFX110 only
F 110 connectionsX
Power
Programming
Display
RS 232 Serial
FX 120 connections1 Remove weigh plate.
FX120
To avoid the risk of RSI (Repetitive Strain Injury) it is important to ensure thatthe machine is placed on a surface which is ergonomically satisfactory to theuser. In cases where usage is prolonged EN614-1 recommends frequentbreaks for the user.
Installation
2
3
4
Connect power cable.
To connect remote display.
Replace the weighplate. Connect to power point.
OR
Fitting the FX 120 scale mounted displayMake sure the scale is not connected to the power supply and remove
weigh plate.
Turn over machine and place on a safe, level surface.
Turn the machine round so the required mounting slot is next to the edge of
the counter.
Remove the screw in the mounting slot.
1
2
3
4
Slot 1
Slot 2
Slot 3 - required mounting slot
Place the mounting bracket into the slot.5
6 Place washer over screw hole and fix with the large replacement screw.
7
8
Refer to the drawings on the following pages and:
Place machine upright.
Do not lift the scale by the column display or the weighplate.
9 Replace the weigh plate. Connect to power point.
Caution:
�
�
�
Plug the display cable into the base.Feed the slack cable round the base.Secure the cable clips.
Cable route: single displayCable from slot 3
Cable from slot 2
Cable from slot 1
12
3
4
5
8
9
6
7
1
2
3
4
1
2
3
4
Cable route: dual displayCable from slot 3
Cable from slot 1
1
2
3
4
12
3
4
5
8
9
6
7
Cable route: dual displayCable from slot 2
Cable from slot 1
1
2
3
4
1
2
3
4
Cable route: dual displayCable from slot 2
Cable from slot 3
12
3
4
5
8
9
6
7
1
5
23
4
Securing the cable clips
FX 120 battery operationNote: Battery operation is not available on the FX110
Plug the battery pack into the scale (use 6 x 1.5v 2‘D’ size cells) and place thepack into the recess. Replace the cover and weighplate.
To avoid damage to the scale caused by leaking batteries, removeflat or damaged batteries immediately.Please note: Rechargable NiCad batteries are not suitable for this applicationdue to their inherent short circuit thermal characteristics which can adverselyaffect the performance of the scale.
When you see the symbol flashing on the display (or Battery LEDflashing), then you must either replace the batteries (or recharge therechargeable battery).
Caution:
Using a rechargeable battery pack
Recharging the battery pack
Note:
- Plug the rechargeable battery packinto the scale and place the pack into the recess. Replace the cover andweighplate.
- Plug the mains cable into the socketlocated on the base of the scale, then switch on using the mains ON/OFFswitch.
You can still use the scale while the battery is being charged.
NiCad
Error messagesIf a persistent error message appears or the scale locks up,disconnect then reconnect the scale to the power supply. If thescale remains inoperative, contact your authorised service agent.
Battery failure.Power supply voltage is too high.Memory checksum invalid.Prohibited function.Prohibited scale capacity.
Tare weight unsteady
Cannot use EPOS tare.Mismatch between EPOS and scale tare increments.
Error codes:
F 10F 11F 30F 35F 36
E 120
E 123E 124
Contact your service agent if you see any other F messeges.
.Tare too heavy.Tare already in operation.
Unit price not accepted.Scale has not returned to zero between EPOS transactions.
E 121E 122
E 130E 131
F 30
Temporaryerror
Weightunsteady
Balancefailed
Underrange
Overrange
Waking up the scaleDepending on configuration...
Either
Displaying service information
Resetting the machine
Selecting sleep mode
Using the scale
Testing the display
Or
LED
LCD
LCD LED
LCD LED
Press and hold
Press and hold
Or
TOr
Weighing goodsPlace the goods onto the scale.
Zeroing the scaleMake sure that the scale is at zero before weighing any goods.
Using tares
Repeat until all the goods have been weighed.
Cumulative tare
T
To cancel a tare
T
TT
Or
LCD LED
Navigating management mode
Example: turn the keyboard bleeper off and change the backlight time to 5seconds.
Management Mode
Entering management mode
Go to the next branch (press and hold)Go to next sub-branch
Go to the previous branch (press and hold)Go to previous sub-branch
Sets the value to 0 enabling you to display a new valueReturn to Branch 00 (press and hold)
C
Branch Sub-branch12 .95
1 Branch ( )12
For Example:
Branch ( )13
Sub-branch ( )Sub-branch ( )
0001
Sub-branch ( )98
Value
0 .00 19 .0119 .00 0
29 .00
04
C
Press and hold
C
Press and hold
Displays the value. Press again to re-displaythe branch / sub-branch
After clearing a value to be changed each key pressincrements the value displayed. Pressing and holdingthe key increments the value by 10.
After changing a value, you mustgo to the next branch to accept the value.Note:
Exit management mode
Press and hold
1
1
LCD
Or
LED
20 .00
C
Press and hold
Press and hold
Switching the keyboard bleeper on/offGo to branch 19, Sub-branch 01
0 = Off1 = On
19 .01
1
Error bleeperGo to branch 19, Sub-branch 03
19 .03
1
Target bleepBranch 19, Sub-branch 02 - Not applicable for this machine.
Changing the bleeper volumeGo to branch 19, Sub-branch 04
0 = Quiet1 = Loud
19 .04
1
0 = always off1 = 5 seconds2 = 1 minute3 = 5 minutes4 = always on
20 .00
1
Changing the backlight timeGo to branch 20, Sub-branch 00
0 = none1 = 1 minute2 = 5 minutes3 = 30 minutes
20 .01
1
Changing the sleep timeGo to branch 20, Sub-branch 01
0 = Off1 = On
Switching the bleeper alarm on/offGo to branch 19, Sub-branch 00
0 = Off1 = On
19 .00
1
Changing the timeout periodGo to branch 74, Sub-branch 02
74 .02
20
Enter a value in units of 10 milliseconds (1-255).For example :200 = 2 seconds150 = 1½ seconds100 = 1 second
Changing the duration of a ‘Long' press (press and hold)
Go to branch 29, Sub-branch 00
29 .00
200
Enter a value in units of 10 milliseconds (50 -255).For example :200 = 2 seconds150 = 1½ seconds100 = 1 second
Enabling key timeoutGo to branch 74, Sub-branch 01
74 .01
1
0 = Disabled1 = Enabled
Declaration of Conformity
The non-automatic weighing instrument
Manufacturer Avery BerkelType
Corresponds to the requirements of the following EC directives:
90/384/EEC*89/336/EEC73/23/EECEN 45 501*EN 50 081-1EN 60 950
*This declaration is only valid if the non-automatic weighing instrument wasverified by the manufacturer or with a certificate of conformity issued by anotified authority.
Non-Automatic Weighing Instruments Directive
EMC Directive
Low Voltage Directive
The applicable harmonised standards are:
FX 110Number of EC type approval certificate UK 2625
Manufacturer Avery BerkelType FX 120Number of EC type approval certificate T5532
This is a class A product. In a domestic environment, this product may causeradio interference in whch case the user may be required to take adequatemeasures.
A copy of the original signed declaration for this instrument is available from:Foundry Lane, Smethwick, West Midlands, England. B66 2LP
EMC Compliance