Brite Energy Solutions - Tom Knoblock - 1-844-533-2897
Transcript
Page 1: Gama LED Parking Lot Lighting

Brite Energy Solutions - Tom Knoblock - 1-844-533-2897

Page 2: Gama LED Parking Lot Lighting

Light Module ——LED Optical Engine

Page 3: Gama LED Parking Lot Lighting
Page 4: Gama LED Parking Lot Lighting

GAMA Series

LED Area Light

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

IMPORTANT INSTALLATION INFORMATION

1.Before commencing installa�on or maintenance, ensure electricity is switched off at the mains. Installa�on or maintenance should be carried out by a qualified electrician.

2.The luminaire must not, under any circumstances, be installed directly to flammable materials, and luminaires must not be covered with any flammable materials.

3.Moun�ng height range of 6 to 12 meters, this model is suitable for outdoor ligh�ng.

4.Ensure there is adequate free air circula�on of at least 50cm around the luminaire. All luminaires run hot. It is the installer's responsibility to consider fire risk and takeappropriate precau�ons.

Model No.

FLB80-T

FLB120-T

No. of LEDs

36

54

System Wa�age

80W

120W

Dimensions (L x W x H)

360(14.17")x330(12.99")x70mm(12.76")

Net Weight Working Environment

6.87kg(15.11lbs.)

Main specifica�ons:

Input Voltage:120-277V~50/60Hz

-40℃-+50℃FLB160-T 72 160W 8.38kg(18.44lbs.)

FLB200-T 90 200W 9.25kg(20.35lbs.)

FLB240-T 108 240W 10.21kg(22.46lbs.)

5.88kg(12.94lbs.)

ARRLUXHuizhou Arrlux Optoelectronic Co.,Ltd

420(16.53")x330(12.99")x70mm(12.76")

480(18.90")x330(12.99")x70mm(12.76")

600(23.61")x330(12.99")x70mm(12.76")

660(26.00")x330(12.99")x70mm(12.76")

EPA* IP

IP65

0.034m²

0.037m²

0.041m²

0.048m²

0.052m²

The ingress protec�on of the fixture is IP65 if the mains supply cable's specifica�on is H07RN-F 3*1.5m㎡.

Model No.

FLC80-T

FLC120-T

No. of LEDs

36

54

System Wa�age

80W

120W

Dimensions (L x W x H)

360(14.17")x330(12.99")x70mm(12.76")

Net Weight Working Environment

6.87kg(15.11lbs.)

Input Voltage:347-480V~50/60Hz

-40℃-+50℃FLC160-T 72 160W 8.38kg(18.44lbs.)

FLC200-T 90 200W 9.25kg(20.35lbs.)

FLC240-T 108 240W 10.21kg(22.46lbs.)

5.88kg(12.94lbs.)

420(16.53")x330(12.99")x70mm(12.76")

480(18.90")x330(12.99")x70mm(12.76")

600(23.61")x330(12.99")x70mm(12.76")

660(26.00")x330(12.99")x70mm(12.76")

EPA* IP

IP65

0.034m²

0.037m²

0.041m²

0.048m²

0.052m²

The ingress protec�on of the fixture is IP65 if the mains supply cable's specifica�on is H07RN-F 3*1.5m㎡.

INSTALLATION INFORMATION

L

W W

Page 5: Gama LED Parking Lot Lighting

Safety No�ce

WIRING INSTRUCTION Alterna�ng Current

Terminal Block

LIVE

GROUND

NEGATIVE

LIVE - Black

NEGATIVE - White

GROUND-Housing

LED D

rivER

Main

s po

wer su

pp

ly

Electrical Connec�ons

L

G

N

Input wire H07RN-F 3x1.5mm² (SJOW 3 * 18AWG) or rubber sheathed cable (not supplied).Conductor must have a minimum cross-sec�onal area of 1.0mm² (18AWG).

STEP I: Connect the LINE wire in the mains power supply cord to black LINE wire from lightbody .

STEP II: Connect the NEUTRAL wire in the mains power supply cord to white NEUTRAL wire from lightbody .

STEP II I: Connect the green grounding wire in the mains power supply cord to green grounding wire from lightbody .

***IF THERE IS JUNCTION BOX IN CEILING:

7

STEP 1: 1.Loosen the M12 screws, nuts, spring washers on the moun�ng arm with a wrench.2.Insert the pole into the middle hole of moun�ng arm �ll to the end.See Figure 1.

STEP 2:When the pole is inside the moun�ng arm, adjust the moun�ng angle of the lamp, then screw the the M12 screws, nuts and spring washers.See Figure 2

21

LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

This logo indicates that this product must not be disposed of with other waste.

Please recycle used lamps to prevent environmental hazard and threats to human

health resul�ng from improper disposal.

Installa�on Instruc�on & Installa�on Steps

Pole

Spring washer(M10)

Moun�ng arm

STEP 7: Reference “Electrical Connec�ons” sec�on for comple�ng electrical connec�ons. See Figure 7

STEP 3: 1. Fix the moun�ng plate on the pole with M10 screws.2. Connect the cables from the luminaire and from the pole. Please See figure 3 the wiring diagram.

STEP 4:1. Fix the luminaire to the moun�ng plate with 4 M6*20 screws.See Figure 4

43

Installa�on and Moun�ng A

M10 screw

M6 screw

Pole Moun�ng plate

Installa�on and Moun�ng A

Installa�on and Moun�ng B Installa�on and Moun�ng B

STEP 5: 1. Fix the moun�ng plate on the wall with M10 screws.2. Connect the cables from the luminaire and from the wall. Please See figure 5 the wiring diagram.

5

Wall

M10 screw

M6 screw

Moun�ng plate

STEP 6:1. Fix the luminaire to the moun�ng plate with 4 M6*20 screws.See Figure 6

6

Wall

Installa�on and Moun�ng C Installa�on and Moun�ng C

Moun�ng arm

Spring washer(M10)

Pole


Recommended