+ All Categories
Home > Documents > GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination...

GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination...

Date post: 19-Jul-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
32
Flueing options and accessories Multiple flue options for Standard and Condensing Boilers GAS BOILERS www.chaffoteaux.co.uk Flueing options and accessories Multiple flue options for Standard and Condensing Boilers FLUE SYSTEMS
Transcript
Page 1: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Flueing options andaccessories

Multiple flue options forStandard andCondensing Boilers

GAS BOILERS

w w w. c h a f f o t e a u x . c o . u k

Flueing options andaccessories

Multiple flue options forStandard andCondensing Boilers

FLUE SYSTEMS

Page 2: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 66772 - C&M - Flueing options and accessories

3

4

2

1

G A S B O I L E R S

www.chaffoteaux.co.uk

Technical GuideThe best combination of comfort and economy

Chaffoteaux & Maury wall-hung gas appliances offer great flexibility in flueingarrangements, to accommodate all installation requirements. This technicalguide will help you to select the correct flue and components, for the locationof the boiler within a property.

1 - Standard Horizontal

The standard flue canrotate through a full 360˚allowing the greatestflexibility in siting.

2 - Raised Horizontal

Using a vertical adaptortogether with standard flueextensions it is possible toextend the overall length ofa standard flue and stillterminate horizontally.

3 - Vertical

For situations where it isnecessary to terminate theflue vertically through atiled or flat roof.

4 - Twin Pipe (Biflux)

Suitable for applicationswhere the appliance iseither sited further from asuitable external wall orwhere building obstructionsdo not allow conventionalhorizontal or vertical flueingarrangements.

Page 3: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Flue Terminal Positions

www.chaffoteaux.co.uk

In accordance with BS 5440-1:2000

C&M - Flueing options and accessories - 3

G A S B O I L E R S

A

B

DEH

I

E

M

I

N

P

P

C

H

LF

JK

Terminal Position mmA Directly below an opening, air brick, opening windows, etc 300B Above an opening, air brick, opening windows, etc 300C Horizontally to an opening, air brick, opening windows, etc 300D Below gutters, soil pipes or drain pipes 75E Below eaves 200F Below balconies or car port roof 200G From vertical drain or soil pipe 150H From an internal or external corner 300I Above ground roof or balcony level 300J From a surface facing the terminal 600K From a terminal facing the terminal 1200L From an opening in the car port (e.g. door, window) into the dwelling 1200M Vertically from a terminal on the same wall 1500N Horizontally from a terminal in the same wall 300P Fixed by use of terminal and matched flashing plate -

Installation Conditions

C&M - Flueing options and accessories - 3

Page 4: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 66774 - C&M - Flueing options and accessories

Flue Types

C&M wall-hung appliances can be fitted up to 15metres from an outside wall using 80/125mm fluecomponents (4 metres using 60/100mm fluecomponents).

As long as the flue terminates horizontally, the mainlength of the flue can be vertical.

Uses standard straight flue extensions and bends.

With a special rubber sealing ring the flue can beinstalled and sealed externally at high levelswithout requiring access to the outside (60/100mmonly).

Unobtrusive terminal.

Simply add bends and straight extensions asrequired to complete the installation (60/100mmonly).

For 80/125mm use the 80/125 vertical adaptor.

Full range of accessories available.

Horizontal incorporating2 x 45˚ bends

Horizontal incorporating45˚ or 90˚ bend

Raised Horizontal,side exit

Raised Horizontal incorporating2 x 90˚ bend and straightextensions

C&M wall-hung appliances can be fitted up to 4metres from an outside wall using the standardhorizontal flue kit.

Full 360˚ rotation of the flue allows the greatestflexibility.

The optional 45˚ and 90˚ bends make the systemideal for boiler changes.

With a special rubber sealing ring the flue can beinstalled and sealed externally at high levelswithout requiring access to the outside.

Unobtrusive terminal.

The standard kit contains all that is necessary for abasic installation.

Full range of accessories available.

4 - C&M - Flueing options and accessories

Raised horizontal

Standard horizontal

Page 5: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 5

G A S B O I L E R S

Flue can terminate vertically up to 16 metres awayfrom the boiler using the 80/125mm Vertical FlueKit (5 metres using the 60/100mm Vertical Flue Kit).

Removes the need to fit the boiler near an outsidewall.

A multitude of accessories make a very adaptableand flexible flue system.

Vertical terminals for flat, sloping, tiled or slatedroofs available.

Terminals and Flashings available in terracottafinish to special order.

Vertical Flue incorporating1 x 90˚ bend and 2 x 45˚bends

Vertical Flue incorporating2 x 90˚ bends

The ultimate in flexibility.

C&M wall-hung boilers can be fitted with upto 30 metres of Biflux flue.

Can terminate on flat, sloping, slated or tiledroofs.

Vertical, horizontal and even separateterminals are available.

Full range of accessories available.

Twin Pipe Flue withsingle vertical terminal

C&M - Flueing options and accessories - 5

Twin Pipe (Biflux)

Vertical

Page 6: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 66776 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

System ConfigurationsList of Contents

Standard Efficiency

Coaxial 60/100 - Standard/Raised Horizontal page 10

Coaxial 60/100 - Vertical page 11

Coaxial 80/125 - Raised Horizontal page 13

Coaxial 80/125 - Vertical page 15

Twin Pipe 80 - Horizontal page 17

Twin Pipe 80 - Vertical page 18

High Efficiency CondensingCoaxial 60/100 - Standard/Raised Horizontal page 21

Coaxial 60/100 - Vertical page 22

Coaxial 80/125 - Raised Horizontal page 24

Coaxial 80/125 - Vertical page 25

Twin Pipe 80 - Horizontal page 27

Twin Pipe 80 - Vertical page 29

Page 7: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 7

G A S B O I L E R S

Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).Figures marked with * relate to the 30 FF model.

MX2 24 FF & 30 FF

Standard Efficiency -Which flue options do you need?

Page 8: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 66778 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

Britony Combi SE, Britony System II,Britony System II Plus & Calydra Comfort

Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).Figures marked with * relate to 100 models.

Standard Efficiency -Which flue options do you need?

Page 9: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 9

G A S B O I L E R S

Calydra Green & Centora Green

Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).

High Efficiency Condensing -Which flue options do you need?

www.chaffoteaux.co.uk

Page 10: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Air/exhaust systems with coaxial tubes Ø 60/100 (horizontal)

10 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.ukwww.chaffoteaux.co.uk

Standard Efficiency - Coaxial

TELESCOPIC HORIZONTAL COAXIAL KIT600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

STANDARD HORIZONTAL COAXIAL KIT1000mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW750mm coaxial kit complete with terminalPacket with gaskets and fixing screwsCover plate in EPDM

90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws

1

1

1

1

707067

705958

705783

705787

0.75m

1.0m

0.75m

0.8m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 11: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 11

G A S B O I L E R S

C&M - Flueing options and accessories - 11

Standard Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (horizontal)

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION160mm coaxial extension with centering springPacket with gaskets and fixing screws

2

1

1

1

705788

705786

705790

705812

0.5m

1.0m

0.5m

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 12: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

Standard Efficiency - Coaxial

12 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL STUB WITH CONDENSATE TRAP160mm coaxial stub with condensate discharge connectionPacket with gaskets and fixing screws

STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws

STANDARD VERTICAL FLUE (TERRACOTTA)

LEAD FLASHING BASE CAP (BLACK)Lead pitched roof flashing with collar

LEAD FLASHING BASE CAP (TERRACOTTA)

2

1

1

1

1

1

1

1

1

705788

705786

705790

705812

705792

705764

705765

705781

705724

0.5m

1.0m

0.5m

0.2m

0.3m

1.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 13: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Standard Efficiency - Coaxial

ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws

HORIZONTAL TERMINAL600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

1

1

706014

61020448 0.6m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

VENT BASE CAP FOR FLAT ROOF (BLACK) 1 704830

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 13

G A S B O I L E R S

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)

Page 14: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

COAXIAL EXTENSION2000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screw

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws

1

1

1

1

1

1

61304857

61304854

61304856

61304853

61304852

61304851

2.0m

1.0m

2.0m

1.0m

0.5m

0.3m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

14 - C&M - Flueing options and accessories

G A S B O I L E R S

Standard Efficiency - Coaxial

www.chaffoteaux.co.uk

Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)

Page 15: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

COAXIAL EXTENSION2000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screw

1

1

1

1

706014

61304854

61304856

61304853

1.0m

2.0m

1.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 15

G A S B O I L E R S

Standard Efficiency - Coaxial

Page 16: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667716 - C&M - Flueing options and accessories

www.chaffoteaux.co.uk

Standard Efficiency - Coaxial

G A S B O I L E R S

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION (TELESCOPIC)50-300mm telescopic coaxial extension with centering springPacket with gaskets and fixing screws

VERTICAL TERMINAL (BLACK) (80/125)Vertical flue kit 80/125

VERTICAL TERMINAL (TERRACOTTA) (80/125)

CONDENSATE TRAPCondense trap with drain point(for use with flues over 5 metres)

LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

VENT BASE CAP FOR FLAT ROOF (BLACK)

1

1

1

1

1

1

1

11111

1

6130485210110

61304851

61304855

61304849

61304850

61010904

61017921

6101792261017923610084606100846161008462

60077757

0.5m

0.2m

0.3m

1.0m

1.0m

0.9m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 17: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

Air/exhaust systems with separate tubes Ø 80 (horizontal)

C&M - Flueing options and accessories - 17

G A S B O I L E R S

Standard Efficiency - Twin Pipe

TWIN PIPE FLUE KITAdaptor 60/80 d 100 for connection to boilerPacket with gaskets and fixing screwsN° 2 90° elbowsN° 2 pipes L1000 MFAir intake terminal

90° MF ELBOW (Ø80)90° elbow in aluminium (white)

90° MF ELBOW (Ø80)

45° MF ELBOW (Ø80)45° elbow in aluminium (white)

PIPE - 2000 mm (Ø80)Pipe L2000 MF in aluminium (white)

1

2

20

2

1

706026

705758

705759

705760

706279

1.3 m

1.0 m

2.0 m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 18: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667718 - C&M - Flueing options and accessories

www.chaffoteaux.co.uk

G A S B O I L E R S

Air/exhaust systems with separate tubes Ø 80 (horizontal)

Air/exhaust systems with separate tubes Ø 80 (vertical)

Standard Efficiency - Twin Pipe

PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)

PIPE - 1000 mm (Ø80)

PIPE - 500 mm (Ø80)Pipe L500 MF in aluminium (white)

INTAKE VENT CAPAir intake Ø80 (plasticl)Fixing screws

STAINLESS STEEL EXHAUST VENT CAPExhaust terminal Ø80 (stainless steel)Fixing screws

1

10

1

1

1

705761

705762

705770

704738

705113

1.0 m

0.5m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 19: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

Air/exhaust systems with separate tubes Ø 80 (vertical)

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 19

G A S B O I L E R S

Standard Efficiency - Twin Pipe

Adaptor (Ø60/80) FOR TWIN PIPE SYSTEMAdaptor Ø60/80 with Ø100 connection to boilerPacket with gaskets and fixing screws

STUB (Ø80) WITH CONDENSATE COLLECTORPipe L85 MF in aluminium (white) with condensate drain

LEAD FLASHING BASE CAP (BLACK)Lead pitched roof flashing with collar

LEAD FLASHING BASE CAP (TERRACOTTA)

VENT BASE CAP FOR FLAT ROOF (BLACK)

VENT CAP (Ø80) FOR VERTICAL TERMINATIONTerminal Ø80 for flat roofs (black)Fixing screws

PIPE REDUCER (Ø118/80)Adaptor for vertical terminal

STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws

STANDARD VERTICAL FLUE (RED)

1

1

1

1

1

1

1

1

705757

705798

705781

705724

704830

705160

707166

705764

705765

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 20: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667720 - C&M - Flueing options and accessories

www.chaffoteaux.co.uk

Air/exhaust systems with separate tubes Ø 80 (special componnets)

G A S B O I L E R S

Standard Efficiency - Twin Pipe

WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs

PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet

COVER PLATE (Ø80)EPDM cover plate

ADAPTOR (Ø80) FOR INSULATED PIPESAdaptor Ø80 for connection insulated exhaust pipescomplete with fixing screws

INSULATED PIPE L 1000Pipe Ø80/100 L 1000 insulatedPacket with gaskets and fixing screws

90° INSULATED ELBOW (Ø80)90° insulated elbow Ø80/100 Packet with gaskets and fixing screws

45° INSULATED ELBOW (Ø80)45° insulated elbow Ø80/100 Packet with gaskets and fixing screw

3

1

2

1

1

1

1

705778

705767

705784

705769

705771

705772

705773

10m

0.2m

1m

1.3m

1m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 21: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 21

G A S B O I L E R S

High Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (horizontal)

STANDARD HORIZONTAL COAXIAL KIT1000mm coaxial kit AL/PP complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW600mm coaxial kit AL/PP complete with terminalPacket with gaskets and fixing screwsCover plate in EPDM

90° COAXIAL ELBOW90° coaxial elbow AL/PPPacket with gaskets and fixing screws

45° COAXIAL ELBOW45° coaxial elbow AL/PPPacket with gaskets and fixing screws

1

1

1

2

61309947

61310156

61309942

61309943

1.0 m

0.75 m

0.8 m

0.5 m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 22: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

G A S B O I L E R S

www.chaffoteaux.co.uk

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)

High Efficiency - Coaxial

22 - C&M - Flueing options and accessories

COAXIAL EXTENSION 1000 mmCoaxial extension 1000mm (Ø60/100)with centering spring

COAXIAL EXTENSION 500 mmCoaxial extension 500mm (Ø60/100)with centering spring

COAXIAL EXTENSION 250 mmCoaxial extension 250mm (Ø60/100)with centering spring

WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs

1

1

1

3

61309946

61309945

61309944

705778

1.0 m

0.5m

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 23: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 23

G A S B O I L E R S

High Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (vertical)

STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws

STANDARD VERTICAL FLUE (TERRACOTTA)

LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

VENT CAP FOR FLAT ROOF (BLACK)

COAXIAL EXTENSION 1000 mmCoaxial extension 1000mm (Ø60 M/F) AL/PPwith centering spring

COAXIAL EXTENSION 500 mmCoaxial extension 500mm (Ø60/100 M/F) AL/PPwith centering spring

COAXIAL EXTENSION 250 mmCoaxial extension 250mm (Ø60/100 M/F) AL/PPwith centering spring

1

1

1

11111

1

1

1

1

61310342

61310343

61017921

6101792261017923610084606100846161008462

60077757

61309946

61309945

61309944

1.0m

1.0m

1.0m

0.5m

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 24: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667724 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.ukwww.chaffoteaux.co.uk

Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)

High Efficiency - Coaxial

ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws

HORIZONTAL TERMINAL600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

1

1

1

1

61309663

61309494

61309165

61309164

0.75m

2.0m

1.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 25: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

High Efficiency - Coaxial

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 25

G A S B O I L E R S

Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

COAXIAL EXTENSION1500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION250mm oaxial extension with centering springPacket with gaskets and fixing screws

1

1

1

1

61309167

61309166

61309169

61309168

1.5m

1.0m

0.5m

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 26: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667726 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws

45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws

COAXIAL EXTENSION1500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws

COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws

VERTICAL TERMINAL (BLACK)600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM

VERTICAL TERMINAL (TERRACOTTA))

1

1

1

1

1

1

1

1

61309663

61309164

61309167

61309166

61309169

61309168

61309163

61310344

1.0m

1.5m

1.0m

0.5m

0.2m

1.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

High Efficiency - Coaxial

Page 27: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 27

G A S B O I L E R S

Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)

Air/exhaust systems with separate tubes Ø 80 (horizontal)

High Efficiency - Coaxial

LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)

VENT BASE CAP FOR FLAT ROOF (BLACK)

1

11111

1

61017921

6101792261017923610084606100846161008462

60077757

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 28: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667728 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

Air/exhaust systems with separate tubes Ø 80 (horizontal)

High Efficiency - Twin Pipe

Adaptor (Ø60/80) FOR TWIN PIPE SYSTEMAdaptor Ø60/80 with Ø100 connection to boilerPacket with gaskets and fixing screws

90° MF ELBOW (Ø80)90° elbow in aluminium (white)

45° MF ELBOW (Ø80)45° elbow in aluminium (white)

PIPE - 1500 mm (Ø80)Pipe L1500 MF in aluminium (white)

PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)

PIPE - 500 mm (Ø80)Pipe L500 MF in aluminium (white)

PIPE - 250 mm (Ø80)Pipe L250 MF in aluminium (white)

1

2

1

1

1

1

1

61309715

61310174

61310173

61310170

61310169

61310171

61310172

1.3m

1.0m

1.5m

1.0m

0.5m

0.2m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 29: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 29

G A S B O I L E R S

Air/exhaust systems with separate tubes Ø 80 (horizontal)

High Efficiency - Twin Pipe

HORIZONTAL TERMINALSExhaust/intake terminals (stainless steel)1000mm Ø80 pipe exhuast1000mm Ø80 pipe intakeEPDM cover plate

1 61310345 2.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Air/exhaust systems with separate tubes Ø 80 (vertical)

Page 30: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 667730 - C&M - Flueing options and accessories

G A S B O I L E R S

www.chaffoteaux.co.uk

High Efficiency - Twin Pipe

Air/exhaust systems with separate tubes Ø 80 (special components)

COVER PLATE (Ø80)EPDM cover plate

WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs

1

1

705784

705778

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Air/exhaust systems with separate tubes Ø 80 (vertical)

PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet

45° MF ELBOW (Ø80)45° elbow in aluminium (white)

PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)

STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws

1

2

1

1

61309715

61310173

61310169

61310168

10m

1.0m

1.0m

SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE

Page 31: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

www.chaffoteaux.co.uk

C&M - Flueing options and accessories - 31

G A S B O I L E R S

Notes

Page 32: GAS BOILERS FLUE SYSTEMS - Heating Spares Ltd · GAS BOILERS Technical Guide The best combination of comfort and economy Chaffoteaux & Maury wall-hung gas appliances offer great flexibility

Supplied By www.heating spares.co Tel. 0161 620 6677

w w w. c h a f f o t e a u x . c o . u k

MTS Building, Hughenden Avenue,High Wycombe, Bucks HP13 5FTTel: 01494 755600Fax: 01494 459775Technical Suppor t Help Line: 01494 539579

MTS (GB) Limited

In th

e in

tere

sts

of o

ur c

usto

mer

s, M

TS (G

B) L

imite

d is

con

tinua

lly d

evel

opin

g th

ese

prod

ucts

to im

prov

e bo

th p

erfo

rman

ce a

nd d

esig

n. W

e th

eref

ore

rese

rve

the

right

to c

hang

esp

ecifi

catio

n w

ithou

t prio

r not

ice.

Thi

s br

ochu

re is

acc

urat

e at

the

date

of p

rintin

g. C

onsu

mer

sta

tuto

ry ri

ghts

are

not

affe

cted

.M

onth

& Y

ear P

rinte

d by

Var

io P

ress


Recommended