+ All Categories
Home > Documents > Gas Outlets/Accessories - Mercury Medical

Gas Outlets/Accessories - Mercury Medical

Date post: 03-Dec-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
36
180 Tubing Mount #06-135012 Stainless steel slide for mounting on wood or metal. #32-22110006 Anodized aluminum bottle holder slide bracket, 4” (10.160cm) #32-22110004 Bottle holder \without lock #32-22110007 Bottle holder w//lock used with #32- 22110005 multi-level bottle bracket Mounting Hole 2 each. #32-22110005 Anodized aluminum multi-level bottle bracket, 3’ (.914m)- does not include #32-22110007 Several bottle holders with lock can be used simultaneously 19mm Tubing adapter #06-135134 Adjustable Slide Bracket Assembly WAGD (EVAC) GRILL ASSEMBLY #32-83160005 INCLUDES: • Mounting hardware with nuts and washers ( 2 each, 8-32 x 2 in. screws) • Scavenging tubing - 19mm diameter x 96 in. length OPTIONAL • Scavenging tubing, per ft. #32-83160006 20 1/2” 1 1/2” 7/32” HOLES 1 3/8” MERCURY MEDICAL ® Page 120 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Accessories
Transcript

180 Tubing Mount

#06-135012Stainless steel slide formounting on wood or metal.

#32-22110006Anodized aluminumbottle holder slidebracket, 4”(10.160cm)

#32-22110004Bottle holder\without lock

#32-22110007Bottle holder w//lockused with #32-22110005 multi-levelbottle bracket

Mounting Hole2 each.

#32-22110005Anodizedaluminummulti-level bottlebracket, 3’(.914m)-does not include#32-22110007

Several bottleholders with lockcan be usedsimultaneously

19mmTubing adapter

#06-135134Adjustable SlideBracket Assembly

WAGD (EVAC) GRILL ASSEMBLY #32-83160005

INCLUDES:• Mounting hardware with nuts and washers

( 2 each, 8-32 x 2 in. screws)• Scavenging tubing - 19mm diameter x 96 in.

length

OPTIONAL• Scavenging tubing, per ft. #32-83160006

20 1/2”

1 1/2”

7/32” HOLES

1 3/8”

MERCURY MEDICAL® Page 120 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Accessories

MERCURY MEDICAL® Page 121 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

D.I.S.S.

Service Part NumberOxygen #06-121100Nitrous Oxide #06-121101Medical Air #06-121102Vacuum #06-121103WAGD (Evacuation) #06-121109Nitrogen #06-121104Carbon Dioxide #06-121110CO2-O2 (CO2>7.5%) #06-121111O2-CO2 (CO2<7.5%) #06-121112HeO2 (He>7.5%) #06-121113O2-He (He<7.5%) #06-121114Slide #06-120978

DIAMETER INDEXSAFETY SYSTEM(D.I.S.S.) OUTLET

OHMEDA (Compatible)QUICK-CONNECT

OUTLET

Chemetron Compatible

Service Part NumberOxygen #06-121040Nitrous Oxide #06-121041Medical Air #06-121042Vacuum #06-121043WAGD (Evacuation) #06-121049Slide #06-120978

Ohmeda Compatible

Service Part NumberOxygen #06-121030Nitrous Oxide #06-121031Medical Air #06-121032Vacuum #06-121033WAGD (Evacuation) #06-121039Slide #06-120978N2 (D.I.S.S.) #06-121104

Service Part NumberOxygen #06-121020Nitrous Oxide #06-121021Medical Air #06-121022Vacuum #06-121023WAGD (Evacuation) #06-121029Slide #06-120978

PURITAN-BENNETT QUICK CONNECT

OUTLET

CHEMETRON (Compatible)QUICK-CONNECT

OUTLET

Gas Outlets/Puritan-Bennett/Beacon Medical

Accessories shall be of a modular designallowing them to be ganged with a BeaconMedical (Puritan-Bennett) manufactured medicalgas outlets on the job site to create a console-like appearance. Each accessory shall consistof a rough-in and finish assembly. All ElectricalAccessories utilize UL/CSA recognized hospitalgrade receptacles. The rough-in for electricaldevices shall include a standard electrical boxfor electrical connections. Gauges shall have apressure range of 0-100 psi for Oxygen, NitrousOxide, Medical air, and Carbon Dioxide; 0-300psi for Nitrogen and 0-30” Hg for Vacuum andEvacuation. Gas specificity shall be maintainedby positive pin indexing between rough-in andfinish assembly. A machined brass outlet blockshall be permanently attached to the mountingplate in such a manner so as to permit the 7-inch long, 3/8” O.D. type K copper inlet tube tobe swiveled 360° for attachment to the pipingsystem. A secondary valve shall be installed inthe outlet block assembly for pressure testingand to prevent gas flow when the gauge isremoved.

Note: Electrical Accessories furnished with5/8” raised device cover. For wall thicknessother than 5/8” customer must furnishcorrect size cover.

2 -1/2”1/4”

5/8”

4”

3”5”

5-3/4”

5”10”15”

20”

4”

1-1/16”

5-3/4” 5”

ELECTRICAL ACCESSORIES

Slides shall be extruded aluminum mounted to a standardinsert and rough-in assembly. Blanks shall consist of astandard rough-in assembly with solid anodized aluminuminsert plate and chrome plated cover plate.

Service Complete AssyGauge O2 (Oxygen) #06-120980

N2O (Nitrous oxide) #06-120981Medical Air #06-120982Vac (Vacuum) #06-120983N2 (Nitrogen) #06-120984

Electrical Twist Lock #06-120970Simplex Receptacle #06-120971Duplex Receptacle #06-120972Hampden Gnd. Recep. #06-120974

Miscellaneous Slide #06-120978Blank, Gas #06-120979Blank, Electrical #06-120969

GAUGE ELECTRICAL SLIDE BLANK

1/2”

5/16”

A maximum of 3 units may be ganged without additional support.

MERCURY MEDICAL® Page 122 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Accessories/Beacon Medaes/Puritan-Bennett

MERCURY MEDICAL® Page 123 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

QUICK CONNECT TYPEFIELD GANGABLE

Ohmeda (Ohio Medical) Compatible Quick Connect Medical Gas outlets shallbe gas specific for the services indicated and accept only correspondingOhmeda (Ohio Medical) Quick Connect adapters. The Outlets shall be ULlisted, CSA approved, and meet NFPA 99 Standards (formally NFPA 56-F). Alloutlets shall be tested and cleaned for oxygen service prior to shipping. Acomplete outlet shall consist of a gas specific finishing assembly to beinstalled after walls are finished and a matching gas specific finishingassembly to be installed after walls are finished.

The rough-in assembly shall be of modular design and include a gas specific16 ga. steel mounting plate designed to permit on-site ganging of multipleoutlets, in any order, on any order, on 5 inch centerline spacing. A machinedbrass outlet block shall be permanently attached to the mounting plate insuch a manner so as to permit the 7 inch long, 3/8” O.D. type K copper inlettube to be swiveled 360o for attachment to the piping system. A secondaryvalve shall be installed in the outlet block assembly for pressure testing andto prevent gas flow when the latch/valve assembly is removed for service. A1/2” high metal flange around the outlet block seal opening shall provide aplaster barrier. Gas service identification shall be affixed to the inlet tube andthe face of the mounting plate. A temporary, transparent cover shall beprovided to keep debris out of the outlet during installation while permittinglabels to be viewed for outlet service identity.

The latch/valve assembly shall include a double seal primary valve and begas specific for the labeled service and accept only corresponding Ohmeda(Ohio Medical) Compatible hose and apparatus adapters. The latch/valveassembly shall be indexed to the corresponding rough-in assembly to avoidaccidental cross-fitting and shall telescope up to 3/4” to allow for variation infinished wall thickness from 1/2” to 1-1/4”. A metal trim plate with permanent,color coded marking of service identification shall be included as part of thelatch/valve assembly.

A die cast, chrome plated coverplate shall be provided to trim each outlet andto fill the space between adjacent outlets. Coverplate design shall allow latchvalves to be individually removed for servicing.

Item Number Service

#06-121030 O2 OHMEDA Q.C.#06-121031 N2O#06-121032 MEDICAL AIR#06-121033 VAC#06-121039 WAGD (EVACUATION)#06-120978 SLIDE#06-121104 N2 (D.I.S.S.)

OHMEDA

• UL Listed/CSA Approved• Meets or exceeds National and

International Codes• Compensates For Variation In Wall

Thickness Up To 3/4”• 360o Swivel Inlet Tube To Simplify

Installation• Gas Specific Indexing• Modular Design For Simplified On-Site

Arrangement• Accepts All Corresponding Ohmeda Gas

Specific Compatible Adapters• Made In the U.S.A.

Gas Outlets/Beacon Medical/Ohmeda Compatible

MERCURY MEDICAL® Page 124 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

The Puritan-Bennett Style Outlet:Easy-to-Use and Reliable.

• Fingertip, push-button release mechanism for secondary equipment.

• Utilizes Chemetron backbox for easy upgrade to Chemetron Completion Kit.

• Die-cast faceplate is chrome-plated for long life and durability.

• Non-interchangeable indexing system, prevents mislabeling.

• Meets NFPA and CGA standards.

• Cleaned and tested for oxygen use.

• Outlet design meets Domestic andInternational standards for medical gasequipment.

• Modular design gives installer flexibility tovary sequence of gases for individual rooms.

• Color-coded outlet has non-interchangeableindexing system to prevent accidental interchange.

• Improved secondary check increases gasflow to patients.

• Easier installation due to adjustability forvarying wall thickness and adjustablerotating inlet tube.

• U.L. and C.S.A. approved.

• Chrome-plated, die-cast faceplate provides durability and improved appearance.

PB STYLE QUICK CONNECT

Oxygen #32-64-03-5001Vacuum #32-64-03-5002Medical Air #32-64-03-5003Nitrous Oxide #32-64-03-5004WAGD (Evacuation) #32-64-03-5006Carbon Dioxide #32-64-03-5007O2/CO2<7% #32-64-03-5008

QUICK CONNECT

#32-64-03-5051#32-64-03-5052#32-64-03-5053#32-64-03-5004#32-64-03-5006#32-64-03-5007#32-64-03-5008

Domestic ISO

DOMESTIC ISO

OXEQUIP Quick Connect Quick ConnectOxygen #21-1930-2112 #21-1930-2121Vacuum #21-1930-2212 #21-1930-2221Medical Air #21-1930-2412 #21-1930-2421Nitrous Oxide #21-1930-2312 #21-1930-2321WAGD (Evacuation) #21-1930-2712 #21-1930-2721Carbon Dioxide #21-1930-2512 #21-1930-2521

D.I.S.S. D.I.S.S.Oxygen #21-1930-1112 #21-1930-1121Vacuum #21-1930-1212 #21-1930-1221Medical Air #21-1930-1412 #21-1930-1421Nitrous Oxide #21-1930-1312 #21-1930-1321WAGD (Evacuation) #21-1930-1712 #21-1930-1721Carbon Dioxide #21-1930-1512 #21-1930-1521

The Oxequip Outlet:Flexibility that meets all the Standards.

Gas Outlets/Allied Healthcare

MERCURY MEDICAL® Page 125 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

SURFACE MOUNTED QUICK-CONNECT WALL STATION(top inlet, 3 5/8” (9.21 cm) centers)

349 Series

#32-64-12-0001 Oxygen#32-64-12-0002 Medical Air#32-64-12-0003 Vacuum#32-64-12-0004 Nitrous Oxide#32-64-12-0005 Oxygen-Blank-Medical Air#32-64-12-0006 Oxygen-Blank-Vacuum#32-64-12-0009 Oxygen-Blank-Nitrous Oxide#32-64-12-0011 Nitrogen#32-64-12-0013 Oxygen-Blank-Oxygen#32-64-12-0016 Vacuum-Blank-Oxygen#32-64-12-0018 Vacuum-Blank-Vacuum

SURFACE MOUNTED D.I.S.S. WALL STATION(top inlet, 3 5/8” (9.21 cm) centers)

347 Series#32-64-15-0001 Oxygen#32-64-15-0002 Medical Air#32-64-15-0004 Oxygen-Blank-Medical Air#32-64-15-0005 Oxygen-Blank-Vacuum#32-64-15-0006 Oxygen-Blank-Nitrous Oxide#32-64-15-0007 Vacuum#32-64-15-0008 Nitrous Oxide#32-64-15-0010 Vacuum-Blank-Vacuum

WALL (FLUSH) QUICK-CONNECT OUTLET STATION500 Series (Field Gangable)#32-64-01-5001 Oxygen#32-64-01-5002 Vacuum#32-64-01-5003 Medical Air#32-64-01-5004 Nitrous Oxide#32-64-01-5006 WAGD (Evacuation)#32-64-01-5007 Carbon Dioxide#32-64-01-5008 95%, 02, 5%, CO2#32-64-01-9431 Blank fascia cover kit#32-64-06-0001 Vacuum bottle slide

Assy

560 Series (Field Gangable)#32-64-04-5601 Oxygen#32-64-04-5602 Vacuum#32-64-04-5603 Medical Air#32-64-04-5604 Nitrous Oxide#32-64-04-5605 Nitrogen#32-64-04-5606 WAGD (Evacuation)#32-64-04-5607 Carbon Dioxide#32-64-04-5608 95% O2, 5% CO2#32-64-06-0001 Vacuum bottle slide Assy#32-64-01-9431 Blank fascia cover kit

HIGH PRESSURE NITROGEN QUICK CONNECT OUTLET STATION#32-64-20-0007 Nitrogen HP (top inlet) DYNACON TYPE

400 Series Top Inlet#32-64-20-0001 Oxygen#32-64-20-0002 Medical Air#32-64-20-0004 Carbon Dioxide#32-64-20-0005 Vacuum#32-64-20-0006 Nitrous Oxide#32-64-20-0003 95%O2, 5%

CO2#32-64-20-0008 WAGD (Evacuation)

#32-64-35-0001 Oxygen#32-64-35-0002 Medical Air#32-64-35-0003 Carbon Dioxide (>7%)#32-64-35-0004 Vacuum#32-64-35-0005 Nitrous Oxide

400 Series Bottom Inlet#32-64-26-0001#32-64-26-0002

#32-64-26-0005

WALL /CEILING (FLUSH) D.I.S.S. OUTLET STATION

460 Series

Gas Outlets/Chemetron/(NCG)

MERCURY MEDICAL® Page 126 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

INTRODUCING THE CONNECT2®MEDICAL GAS OUTLET STATION NEW

ONE OUTLETTWO ADAPTERS

q Ideal for institutionswith more than one typeof quick connect.

q Great for emergencydepartments receivingtransported patients withancillary gas services.

• The first medical gas outlet that acceptsboth Chemetron and Ohmeda adapters(patent pending design).

• Push button mechanism for quick adapterrelease. Ohmeda adapter has secondmethod of release with twisted feature.

• Chemetron adapter can support secondaryequipment, including a suction regulatorwith 1/2 gallon collection bottle.

• Eliminates need for hospital personnel tocarry both styles of adapters to ensureproper connection.

• Fail-safe color coding and safety keyedto ensure appropriate gas.

• Valve body O-ring easily accessible for maintenance. Inlet tube has secondarycheck unit to permit removal of valve bodywithout shutting off gas to the outlet.

• U.L. approved.

The Right Connection ForNew Or Existing Structures

3/8” flared connection

Faceplate is safetykeyed to backplate

Stainless steel

Push-button release

Keying for Chemetron Adapter

Keying for OhmedaAdapter

Chrome plated Faceplate

ChemetronAdapter

OhmedaAdapter

Inlet tube capable of rotating 360o

Adjustment for variouswall thicknesses

CONNECT2CONNECT2 5 1/4” Width5 1/4” Width

Oxygen #32-64-02-5001Vacuum #32-64-02-5002Medical Air #32-64-02-5003Nitrous Oxide #32-64-02-5004WAGD (Evacuation) #32-64-02-5006Carbon Dioxide #32-64-02-5007O2/CO2<7% #32-64-02-5008Wall Slide #32-64-06-0001

FASCIA ASSEMBLIESCONVERT EXISTING Chemetron 500 SERIES OR 560 SERIESOUTLETS TO DUAL CAPABILITY

Oxygen #32-64-02-9531Vacuum #32-64-02-9532Medical Air #32-64-02-9534Nitrous Oxide #32-64-02-9533

2 1/4” Width 2 3/4” WidthGas Outlet Fascia Outlet FasciaOxygen #32-64-02-4011 #32-64-90-4011 #32-64-02-4001 #32-64-90-4001Vacuum #32-64-02-4012 #32-64-90-4012 #32-64-02-4002 #32-64-90-4002Medical air #32-64-02-4014 #32-64-90-4014 #32-64-02-4004 #32-64-90-4004Nitrous Oxide #32-64-02-4013 #32-64-90-4013 #32-64-02-4003 #32-64-90-4003(WAGD) Evacuation #32-64-02-4018 #32-64-90-4018 #32-64-02-4008 #32-64-90-4008Carbon Dioxide #32-64-02-4015 #32-64-90-4015 #32-64-02-4005 #32-64-90-4005

Gas Outlets/Dual Adapters

MERCURY MEDICAL® Page 127 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

FEATURES:• Accepts only Chemetron gas

specific adapters• Indexed to prevent

interchangeability of gas services

• Universal rough-in accepts quick connection (Chemetron®,Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies

• Modular design capability• 100% hydrostatically tested• Complies with NFPA 99 and CGA G-4.1 standards• UL Listed

SPECIFICATIONS:Medical gas outlet(s) shall be manufactured by GenstarTechnologies Co., Inc. (GENTEC®). Wall outlet shall bedesigned for concealed piping installation and available forservices indicated.

The latch valve assembly shall be Chemetron quick connectcompatible and accept only gas specific Chemetron type quickconnect adapters. Each latch valve assembly shall be color-coded for ease of gas identification per the appropriatestandards (US or ISO). Latch valve assemblies shall have gasspecific pin indexing corresponding to the rough-in assembly toprevent interchangeability of gas services and shall adjust up to1” for variations in wall thickness.

Universal rough-in assembly shall include the wall rough-inplate (16 ga.) with inlet tubing silver brazed to the outlet body.Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD,extend 6-1/2 inches (165 mm), and swivel 360° for ease ofinstallation. Rough-in assembly shall accept only the specifiedgas service by use of indexes. Rough-in assembly shall be ofmodular design to permit on-site ganging of multiple outletswith assurance of accurate alignment and providing 5”centerline spacing. A dust plug and cover shall be provided toprotect rough-in assembly from contamination during handlingand installation at the job site.

Rough-in assemblies shall accept any latch valve assembly ofthe same gas service. The latch valve assembly shall beinterchangeable, allowing conversion from one connectionstyle to another without shutting down the medical gassystem.

All positive pressure gas outlets shall have a primary andsecondary check valve, where the secondary valve in therough-in assembly allows servicing of the latch valveassembly without having to disrupt gas service to the outlet.

Complete outlet shall be delivered to the customer in a gasspecific rough-in assembly, a matching gas specific latchvalve assembly, both cleaned for oxygen use and in a sealedpackage, and a trim plate. All assemblies shall be 100%tested for leaks, manufactured to comply with the latestedition of NFPA 99, and UL Listed.

FEATURES:• Accepts only Ohmeda gas

specific adapters• Indexed to prevent

interchangeability of gas services

• Universal rough-in accepts quick connection (Chemetron®,Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies

• Modular design capability• 100% hydrostatically tested• Complies with NFPA 99 and CGA G-4.1 standards• UL Listed

SPECIFICATIONS:Medical gas outlet(s) shall be manufactured by GenstarTechnologies Co., Inc. (GENTEC®). Wall outlet shall bedesigned for concealed piping installation and available forservices indicated.

The latch valve assembly shall be Ohmeda quick connectcompatible and accept only gas specific Ohmeda type quickconnect adapters. Each latch valve assembly shall be color-coded for ease of gas identification per the appropriatestandards (US or ISO). Latch valve assemblies shall have gasspecific pin indexing corresponding to the rough-in assemblyto prevent interchangeability of gas services and shall adjustup to 1” for variations in wall thickness.

Universal rough-in assembly shall include the wall rough-inplate (16 ga.) with inlet tubing silver brazed to the outlet body.Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD,extend 6-1/2 inches (165 mm), and swivel 360° for ease ofinstallation. Rough-in assembly shall accept only the specifiedgas service by use of indexes. Rough-in assembly shall be ofmodular design to permit on-site ganging of multiple outletswith assurance of accurate alignment and providing 5”centerline spacing. A dust plug and cover shall be provided toprotect rough-in assembly from contamination during handlingand installation at the job site.

Rough-in assemblies shall accept any latch valve assembly ofthe same gas service. The latch valve assembly shall beinterchangeable, allowing conversion from one connectionstyle to another without shutting down the medical gassystem.

All positive pressure gas outlets shall have a primary andsecondary check valve, where the secondary valve in therough-in assembly allows servicing of the latch valveassembly without having to disrupt gas service to the outlet.

Complete outlet shall be delivered to the customer in a gasspecific rough-in assembly, a matching gas specific latchvalve assembly, both cleaned for oxygen use and in a sealedpackage, and a trim plate. All assemblies shall be 100%tested for leaks, manufactured to comply with the latestedition of NFPA 99, and UL Listed.

Gas Outlets/Genstar Tech (continued on next page)

MERCURY MEDICAL® Page 128 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Dimensional Data Notes:A. Additional support needed if ganging more than 3

outletsB. Wall thickness may vary from 1/2” to 1”

(12.7mm to 25.4mm).C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube

allows 360° swivel on outlet body for entry from any angle.

D. Inch (mm)

ORDERING INFORMATIONCHEMETRON COMPATIBLE

Gas Service Item #Oxygen #ES-3823U-OVacuum #ES-3823U-VMedical Air #ES-3823U-ANitrous Oxide #ES-3823E-2WAGD #ES-3823U-WSlide #ES-3820-SLD

DIMENSIONS: (Chemetron)

Dimensional Data Notes:A. Additional support needed if ganging more than 3

outletsB. Wall thickness may vary from 1/2” to 1”

(12.7mm to 25.4mm).C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube

allows 360° swivel on outlet body for entry from any angle.

D. Inch (mm)

ORDERING INFORMATIONOHMEDA COMPATIBLE

Gas Service Item #Oxygen #ES-3821U-OVacuum #ES-3821U-VMedical Air #ES-3821U-ANitrous Oxide #ES-3821E-2WAGD #ES-3821U-WSlide #ES-3820-SLD

MATERIALLatch Valve Trim Plate Rough-inAluminum Cast Aluminum Stainless SteelABS Plastic Powder Coating ABS PlasticSteel/Brass + Plating NeopreneStainless Steel Steel + PlatingBrass CopperNeopreneRubber

MATERIALLatch Valve Trim Plate Rough-inAluminum Cast Aluminum Stainless SteelABS Plastic Powder Coating ABS PlasticSteel/Brass + Plating NeopreneStainless Steel Steel + PlatingBrass CopperNeopreneRubber

DIMENSIONS: (Ohmeda)

Ordering Information for Complete Wall Outlets (Includes Latch Valve Assembly, Trim Plate and Rough-in Assembly)Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers.

Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly)Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers.

Gas Outlets/Genstar Tech (continued from previous page)

MERCURY MEDICAL® Page 129 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

FEATURES:• Accepts only DISS gas specific

adapters• Indexed to prevent interchangeability

of gas services• Universal rough-in accepts quick

connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies

• Modular design capability• 100% hydrostatically tested• Complies with NFPA 99 and CGA

G-4.1 standards• UL Listed

SPECIFICATIONS:Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc.(GENTEC®). Wall outlet shall be designed for concealed piping installation andavailable for services indicated.

The latch valve assembly shall be Compressed Gas Association (CGA) DiameterIndex Safety System (DISS) threaded connectors and accept only correspondinggas specific type nut and nipple adapters. Each latch valve assembly shall becolor-coded for ease of gas identification per the appropriate standards (US orISO). Latch valve assemblies shall have gas specific pin indexing corresponding tothe rough-in assembly to prevent interchangeability of gas services and shalladjust up to 1” for variations in wall thickness.

Universal rough-in assembly shall include the wall rough-in plate (16 ga.) withinlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper,1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease ofinstallation. Rough-in assembly shall accept only the specified gas service byuse of indexes. Rough-in assembly shall be of modular design to permit on-siteganging of multiple outlets with assurance of accurate alignment and providing5” centerline spacing. A dust plug and cover shall be provided to protect rough-in assembly from contamination during handling and installation at the job site.

Rough-in assemblies shall accept any latch valve assembly of the same gasservice. The latch valve assembly shall be interchangeable, allowing conversionfrom one connection style to another without shutting down the medical gaspiping system.

All positive pressure gas outlets shall have a primary and secondary checkvalve, where the secondary valve in the rough-in assembly allows servicing ofthe latch valve assembly without having to disrupt gas service to the outlet.

Complete outlet shall be delivered to the customer in a gas specific rough-inassembly, a matching gas specific latch valve assembly, both cleaned foroxygen use and in a sealed package, and a trim plate. All assemblies shall be100% tested for leaks, manufactured to comply with the latest edition of NFPA99, and UL Listed.

FEATURES:• Accepts only Puritan-Bennett gas

specific adapters• Indexed to prevent interchangeability

of gas services• Universal rough-in accepts quick

connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies

• Modular design capability• 100% hydrostatically tested• Complies with NFPA 99 and CGA

G-4.1 standards• UL Listed

SPECIFICATIONS:Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc.(GENTEC®). Wall outlet shall be designed for concealed piping installation andavailable for services indicated.

The latch valve assembly shall be Puritan-Bennett quick connect compatible andaccept only gas specific Puritan-Bennett type quick connect adapters. Eachlatch valve assembly shall be color-coded for ease of gas identification per theappropriate standards (US or ISO). Latch valve assemblies shall have gasspecific pin indexing corresponding to the rough-in assembly to preventinterchangeability of gas services and shall adjust up to 1” for variations in wallthickness.

Universal rough-in assembly shall include the wall rough-in plate (16 ga.) withinlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper,1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease ofinstallation. Rough-in assembly shall accept only the specified gas service byuse of indexes. Rough-in assembly shall be of modular design to permit on-siteganging of multiple outlets with assurance of accurate alignment and providing5” centerline spacing. A dust plug and cover shall be provided to protect rough-in assembly from contamination during handling and installation at the job site.

Rough-in assemblies shall accept any latch valve assembly of the same gasservice. The latch valve assembly shall be interchangeable, allowing conversionfrom one connection style to another without shutting down the medical gassystem.

All positive pressure gas outlets shall have a primary and secondary checkvalve, where the secondary valve in the rough-in assembly allows servicing ofthe latch valve assembly without having to disrupt gas service to the outlet.

Complete outlet shall be delivered to the customer in a gas specific rough-inassembly, a matching gas specific latch valve assembly, both cleaned foroxygen use and in a sealed package, and a trim plate. All assemblies shall be100% tested for leaks, manufactured to comply with the latest edition of NFPA99, and UL Listed.

American Medical Gas Outlets Gentec Medical Gas Outlets shall be ULListed, cleaned for medical gas service,and compliant to the latest edition ofNFPA 99. They shall accept onlycorresponding Ohmeda®, DISS,Chemetron®, or Puritan Bennett® stylequick connect adapters. Outlets aredesigned with an universal rough-inassembly for interchangeability ondifferent quick connects withoutremoving the entire outlet. For outletsproviding positive pressure gas, theyshall have a primary and secondarycheck valve, where the secondary check valve allows for servicing without isolating an entire zone.

Latch Valve Assembly (front)The latch-valve assembly shall have gas specific index corresponding to thegas service on the rough-in assembly to prevent interchanging of gas service.Each latch-valve assembly shall be color coded for it’s specified gas service.

Rough-In Assembly (back)The rough-in assembly shall bemanufactured using (1/2" O.D.) type “K”copper tubing, silver-brazed to the outletbody. The tubing allows 360 degreesswivel on the outlet body for easyinstallation. Rough-in assembly ismanufactured to accept only thespecified gas service by use of indexes.

Features• Accepts only Ohmeda®, DISS,

Chemetron®, or Puritan Bennett®style gas specific adapters

• Unique pin index for gases to preventinterchanging of gas service

• Universal rough-in assembly • Color-coded for easy gas identification • 360° swivel on the inlet pipe for easy

installation • UL listed and complies to the latest

edition of NFPA 99 • Type K, 3/8" size copper tubing [1/2"

real O.D. (12.7mm)] • 100% hydrostatically tested

Latch Valve Assembly + Rough-In Assembly = Complete Assembly

Gas Outlets/Genstar Tech (continued on next page)

MERCURY MEDICAL® Page 130 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Dimensional Data Notes:A. Additional support needed if ganging more than 3

outletsB. Wall thickness may vary from 1/2” to 1”

(12.7mm to 25.4mm).C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube

allows 360° swivel on outlet body for entry from any angle.

D. Inch (mm)

ORDERING INFORMATIONDISS STANDARD

Gas Service Item #Oxygen #ES-3822U-OVacuum #ES-3822U-VMedical Air #ES-3822U-ANitrous Oxide #ES-3822E-2WAGD #ES-3822U-WCarbon Dioxide #ES-3822E-CNitrogen #ES-3822E-NSlide #ES-3820-SLD

DIMENSIONS: (DISS)

Dimensional Data Notes:A. Additional support needed if ganging more than 3

outletsB. Wall thickness may vary from 1/2” to 1”

(12.7mm to 25.4mm).C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube

allows 360° swivel on outlet body for entry from any angle.

D. Inch (mm)

ORDERING INFORMATIONPURITAN-BENNETT COMPATIBLE

Gas Service Item #Oxygen #ES-3824U-OVacuum #ES-3824U-VMedical Air #ES-3824U-ANitrous Oxide #ES-3824E-2WAGD #ES-3824U-WSlide #ES-3820-SLD

MATERIALLatch Valve Trim Plate Rough-inAluminum Cast Aluminum Stainless SteelABS Plastic Powder Coating ABS PlasticSteel/Brass + Plating NeopreneStainless Steel Steel + PlatingBrass CopperNeopreneRubber

MATERIALLatch Valve Trim Plate Rough-inAluminum Cast Aluminum Stainless SteelZinc Alloy Powder Coating ABS PlasticABS Plastic NeopreneSteel + Plating Steel + PlatingStainless Steel CopperBrassNeopreneRubber

DIMENSIONS: (Puritan-Bennett)

Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly)Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers.

Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly)Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers.

Gas Outlets/Genstar Tech (continued from previous page)

MERCURY MEDICAL® Page 131 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Oxequip® Med*Star® Quick-Connect Medical Gas OutletsElements• Safety keyed to prevent cross-connections• Conforms to NFPA 99 and CSA standards• Accepts Med*Star and ‘07 Series Adapters• Modular design• Cleaned for oxygen service• UL Listed

DescriptionThe Oxequip® Med*Star® Series outlet stations provide convenient access to medicalgases in patient care locations. They are fully compatible with Med*Star and ’07 Seriesadapters.

The outlets can be grouped together in any order desired by the facility. Outlets arespaced 5" (12.7 cm) center to center. Outlet finish plates and rough-in plates are pinindexed using steel pins for positive cross-connection prevention. Valve bodies areseparate from the finish plate, allowing easy testing for leaks and cross connection, andcontain a self-sealing poppet. Valve bodies are field adjustable to compensate for variations in plaster thickness of 12.7 mm (1/2") to19 mm (3/4").

The 152.5 mm (6") Type K copper inlet tube has a 9.5 mm (3/8") ID (12.7 mm (1/2") OD) connection, and can rotate 360 degrees toaccommodate any field piping arrangement. The primary gas check can be serviced without shutting off the gas supply.

The cam plate contains a positive latching mechanism to retain the adapter in the outlet. The adapter is removed by operating therelease mechanism which is integral to the Med*Star adapter (’07 Series adapters use the twist mechanism).

All components (cam plate, tumbler, valve body, poppet, faceplate) are individually field replaceable.

The outlet stations are fully compliant with NFPA 99 (2002) and CSA Z-305, and are cleaned for oxygen service in accordance withCGA G-4.1. The outlet is UL listed. Rough-in plates for the outlets are zinc plated steel for corrosion resistance and fire safety. Finishplates are die-cast zinc, chrome-plated with brushed stainless inserts for appearance. Gas identification is provided by apolycarbonate plastic insert, color-coded by gas service.

The cam plate/tumbler assembly is color-coded and labeled for the gas service. Release is easily accomplished with one hand usingthe adapter release mechanism. The primary valve poppet provides a dust proof seal. Vacuum outlets may be used with or withoutslide brackets for vacuum collection bottles of up to 2 liters (1/2 gallon) capacity (where slides are used, provide one per vacuumoutlet).

Ordering InformationGas Service Item #

(US Color Codes)Oxygen #21-1930-2111Vacuum #21-1930-2211Air #21-1930-2411Nitrous Oxide #21-1930-2311WAGD #21-1930-2811Carbon Dioxide #21-1930-2511Slide Bracket #21-1857-A

Dimensional Data

Gas Outlets/Oxequip

MERCURY MEDICAL® Page 132 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Oxequip® Med*Star® DISS Medical Gas OutletsElements• Safety keyed to prevent cross-connections• Conforms to NFPA 99 and CSA standards• Modular design• Cleaned for oxygen service• UL Listed

DescriptionThe Oxequip Diameter Index Safety System (DISS) Series outlet stations provideconvenient access to medical gases in patient care locations. They are fully compatiblewith DISS style diameter indexed threaded adapters.

The outlets can be grouped together in any order desired by the facility. Outlets arespaced 5" (12.7 cm) center to center. Outlet finish plates and rough-in plates are pinindexed using steel pins for positive cross-connection prevention. The chrome-platedbrass valve bodies contain a self-sealing poppet, and are separate from thefinish plate, allowing easy testing for leaks and cross connection. Valve bodies are fieldadjustable to compensate for variations in plaster thickness of 12.7 mm (1/2") to 19 mm (3/4").

The 152.5 mm (6") Type K copper inlet tube has a 9.5 mm (3/8") ID (12.7 mm (1/2") OD) connection, and can rotate 360 degrees toaccommodate any field piping arrangement. The primary gas check can be serviced without shutting off the gas supply.

The outlet stations are fully compliant with NFPA 99 (2002) and CSA Z-305, and are cleaned for oxygen service in accordance withCGA G-4.1. The outlet is UL listed. Rough-in plates for the outlets are zinc plated steel for corrosion resistance and fire safety. Finishplates are die-cast zinc, chrome-plated with brushed stainless inserts for appearance. Gas identification is provided by apolycarbonate plastic insert, color-coded by gas service.

Vacuum outlets may be used with or without slide brackets for vacuum collection bottles of up to 2 liters (1/2 gallon) capacity (whereslides are used, provide one per vacuum outlet).

Ordering InformationGas Service Item #

(US Color Codes)Oxygen #21-1930-1111Vacuum #21-1930-1211Air #21-1930-1411Nitrous Oxide #21-1930-1311WAGD #21-1930-1811Carbon Dioxide #21-1930-1511Nitrogen #21-1930-1611Slide Bracket #21-1857-A

Dimensional Data

Gas Outlets/Oxequip

MERCURY MEDICAL® Page 133 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Flush Mounted “Twist Sleeve” Wall Outlets

#35-040000300 Single wall outlet for oxygen

#35-040000200 Single wall outlet for nitrous oxide

#35-040000400 Single wall outlet for vacuum

#35-040000100 Single wall outlet for medical air

Gas Outlets/Schrader

MERCURY MEDICAL® Page 134 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

QUICK-CONNECT (OHMEDA COMPATIBLE)

#GP-Q1132 WAGD (evacuation) recessed outlet#GP-Q1124 Oxygen recessed outlet#GP-Q1122 Vacuum recessed outlet#GP-Q1116 Medical air recessed outlet#GP-Q1104 Nitrous Oxide recessed outlet

#GP-Q2132 WAGD (evacuation) exposed outlet#GP-Q2124 Oxygen exposed outlet#GP-Q2122 Vacuum exposed outlet#GP-Q2116 Medical air exposed outlet#GP-Q2104 Nitrous Oxide exposed outlet

D.I.S.S. WALL OUTLETS

#GP-F1132 WAGD (evacuation) recessed outlet#GP-F1124A Oxygen recessed outlet#GP-F1122 Vacuum recessed outlet#GP-F1116 Medical air recessed outlet#GP-F1112 Nitrogen recessed outlet#GP-F1104 Nitrous Oxide recessed outlet

#GP-F2132 WAGD (evacuation) exposed outlet#GP-F2124A Oxygen exposed outlet#GP-F2122 Vacuum exposed outlet#GP-F2116 Medical air exposed outlet#GP-F2112 Nitrogen exposed outlet#GP-F2104 Nitrous Oxide exposed outlet

#GP-F1144 Slide Bracket for recessed outlets

Gas Outlets/Tri-Tech

MERCURY MEDICAL® Page 135 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

CHEMETRONCOMPATIBLE WALL OUTLETS CEILING OUTLETS

OXYGENMEDICAL AIRVACUUMNITROUS OXIDEWAGD (EVACUATION)VAC. SLIDE

AM-OCHWALU-OXYAM-OCHWALU-AIRAM-OCHWALU-VACAM-OCHWALU-N2OAM-OCHWALU-EVAAM-OWALSLIDE

N/AN/AN/AN/AN/AN/A

OHMEDACOMPATIBLE

OXYGENMEDICAL AIRVACUUMNITROUS OXIDEWAGD (EVACUATION)VAC. SLIDE

WALL OUTLETS CEILING OUTLETS

AM-OQDWALU-OXYAM-OQDWALU-AIRAM-OQDWALU-VACAM-OQDWALU-N2OAM-OQDWALU-EVAAM-OWALSLIDE

N/AN/AN/AN/AN/AN/A

PURITAN-BENNETTCOMPATIBLE

OXYGENMEDICAL AIRVACUUMNITROUS OXIDEWAGD (EVACUATION)VAC. SLIDE

WALL OUTLETS CEILING OUTLETS

N/AN/AN/AN/AN/AN/A

AM-OPBWALU-OXYAM-OPBWALU-AIRAM-OPBWALU-VACAM-OPBWALU-N2OAM-OPBWALU-EVAAM-OWALSLIDE

D.I.S.S. DIAMETERINDEX SATY SYSTEM

WALL OUTLETS CEILING OUTLETS

AM-ODISWALU-OXYAM-ODISWALU-AIRAM-ODISWALU-VACAM-ODISWALU-N2OAM-ODISWALU-NITAM-ODISWALU-CO2AM-ODISWALU-EVAAM-ODISWALU-INAAM-OWALSLIDE

OXYGENMEDICAL AIRVACUUMNITROUS OXIDENITROGENCARBON DIOXIDEWAGD (EVACUATION)INSTRUMENT AIRVAC. SLIDE

AM-ODISCELU-OXYAM-ODISCELU-AIRAM-ODISCELU-VACAM-ODISCELU-N2OAM-ODISCELU-NITAM-ODISCELU-CO2AM-ODISCELU-EVA

Gas Outlets/AMICO

Description Item Number1. Box #98-408-1463-3002. Spring Clip #98-203-5081-3043. Primary Check Spring #98-203-4042-300

(10 Pkg) #98-203-3219-870 4. Inlet Screen #98-214-7162-3005. Secondary Ball Check #98-409-1697-3006. Secondary Check Spring #98-203-3230-300

(10 Pkg) #98-203-3215-8707. Secondary Check O-ring #98-210-0629-300

(10 Pkg) #98-210-0492-8708. O-ring #98-210-0703-300

(10 Pkg) #98-210-0497-8709. Retainer; Vacuum #98-221-2440-500

Pressure Gases #98-221-2524-50010. Quad Ring #98-210-4512-300

(10 Pkg) #98-210-4513-87011. Locking Spring #98-203-5064-30012. Primary Check O-ring #98-210-0572-300

(10 Pkg) #98-210-0489-87013. Piston #98-6803-7030-03014. Screw #98-1406-6113-10515. Keying Disc with Ears

Oxygen #98-221-2400-100Nitrous Oxide #98-221-2401-100Vacuum #98-221-2402-100Medical air (Black) #98-221-2403-100Medical air (Yellow) #98-221-2422-100Evacuation #98-221-2404-600Carbon Dioxide #98-397-0000-804

Keying Disc Without EarsOxygen #98-221-2405-100Nitrous Oxide #98-221-2406-100Vacuum #98-221-2407-100Medical air (Yellow) #98-221-2421-100Medical air (Black) #98-221-2408-100WAGD (Evacuation) #98-221-2409-600Carbon Dioxide #98-397-0000-803

16. Screw, Keying Disc #98-0140-6224-10617. Name Plate Label

Oxygen #98-205-4610-300Nitrous Oxide #98-205-4611-300Vacuum #98-205-4612-300Medical air (Black) #98-205-4613-300Medical air (Yellow) #98-205-4614-300

18. Screw, Name Plate #98-142-2243-21019. Name Plate #98-221-2515-54220. Primary Check Body

New Style; for use withPlastic Keying Disc #98-221-2420-500Old Style; For use withmetal keying disc #98-221-2523-500

21. Maintenance Kit #98-680-3720-0002Pressure and VacuumIncludes 1 each of Items #3,6,7,8,10,11

1.2. 20.

19.

18.

17.1.

16.

14.

13.

12.

15.

9.8.

7.

6.

5.

4.

3.

10. 11.

Keying Disc (Item #15) is held in place by 2 screws.

MERCURY MEDICAL® Page 136 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Beacon Medaes/Breakdowns/Diamond I Series

Repair parts are no longer available for Diamond II outlets. Theseoutlets must be converted to a Diamond III outlet to correct problems.

3 EASY STEPS

1. Select appropriate Conversion Kit(s);Pressure gases (O2, N2O, Medical air & CO2) #98-221-3976-870Vacuum & Evacuation #98-221-3976-871Above Kits include10 each of Item #’s 3, 5, 6 & 7

2. Order desired quantity of secondary check units,Item number 4 below #98-221-3970-500

3. Select appropriate finishing assemblyOxygen #98-221-3982-800Nitrous Oxide #98-221-3982-801Vacuum #98-221-3982-802Medical air #98-221-3982-803Carbon Dioxide #98-221-3982-804WAGD (Evacuation) #98-221-3982-805

MERCURY MEDICAL® Page 137 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Beacon Medaes/Breakdowns/Diamond II Series

Description Item Number

16. O-ring (10 Each) #98-0210-0491-87017. Washer #98-0402-1130-30018. Lock-in Adapter Spring #98-0203-5129-870

(10 Each)19. Detail for replacing spring assembly20. Keying Disc Wall Mounted Console Mounted

Oxygen #98-0221-1500-600 #98-0221-3919-600Nitrous Oxide #98-0221-1501-600 #98-0221-3915-600Vacuum #98-0221-1502-600 #98-0221-3920-600Medical Air #98-0221-1508-600 #98-0221-3921-600Carbon Dioxide #98-0221-1509-600 N/AWAGD (Evacuation) #98-0221-1507-600 N/ANitrogen N/A N/A

21. Eyelet (2), (50 Each) #98-0203-5643-87022. Finish Plate #98-0221-1464-50023. Screw, 6-32 x 1-1/2” (2) #98-0140-6324-124

Secondary Check Repair Kit for 10 Outlets10 Each of items 3, 5, 6 and 7 forPressure Gases #98-0221-3976-870

Secondary Check Repair Kit for 10 Outlets10 Each of items 3, 5, 6 and 7 for Vacuum and WAGD #06-290803PG

Primary Check Repair Kit for 10 OutletsRepair Kit with 10 Each of items 5, 1112, 16, 17 and 18; and 30 each of item 21 #06-290804PG

Description Item Number

1. Back Body #98-0221-3954-7012. O-ring #98-0210-0706-3003. Spring, bronze for Pressure Gases

(10 Each) #98-0203-3217-870Stainless Steel for Vacuum andWAGD (10 each) #98-0203-3218-870

4. Secondary Check #98-0221-3970-5005. O-ring (10 each) #98-0210-0491-8706. Rubber Bushing (10 Each) #98-6803-2030-0007. Ring, 1” Spirolex (10 Each) #98-6803-2030-0018. Back Plate 9. Screw, 8 x 5/8 (2) #98-6812-2000-075

10. Ring, 1.125” Spirolex #98-6812-2000-40411. Spring (10 Each) #06-833436PG12. Piston (10 Each) #98-0221-1587-87013. Gasket (2) #98-0210-0070-30014. Cover Plate (with logo) #98-0221-1528-10015. Front Body Cylinder #98-0221-3960-500

Diamond III Series(Stamped with 300 Series Number on

Back Side of Cover Plate, #14)

MERCURY MEDICAL® Page 138 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Breakdowns/Diamond III Series

MERCURY MEDICAL® Page 139 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Quick Connect

D.I.S.S.

14

12

1012

10

8

4

6

3

11

SEE next page for ordering Numbers

Gas Outlets/Beacon Medical (Puritan-Bennett) Series “A”

PART ITEM NUMBER DESCRIPTION

3. #06-814051 Screw (Tie Bar)4. #06-826001 Tinnerman 6/32 Speed nut6. #06-815301 Screw (Block Mounting)8. #06-815321 Shoulder Screw

10. #06-230240 D.I.S.S. Valve (O2)#06-230241 D.I.S.S. Valve (N2O)#06-230242 D.I.S.S. Valve (Medical air)#06-230243 D.I.S.S. Valve (Vac)#06-211170 Quick Connect Valve (O2)#06-211171 Quick Connect Valve (N2O) #06-211172 Quick Connect Valve (Medical air)#06-211173 Quick Connect Valve (Vac)

11. #06-425211 Escutcheon (Single)#06-425212 Escutcheon (Double)#06-425213 Escutcheon (Triple)#06-425214 Escutcheon (Quad)#06-425215 Escutcheon (Quint.)

12. #06-230320 D.I.S.S.-Insert Plate Assy. (O2) (Includes Dust #06-230321 D.I.S.S.-Insert Plate Ass. (N2O Cover/Chain)#06-230322 D.I.S.S.-Insert Plate Assy. (Medical air) #06-230323 D.I.S.S.-Insert Plate Assy. (Vac) #06-230324 D.I.S.S.-Insert Plate Assy. (N2)#06-230300 Q.C. - Insert Plate Assy. (O2)#06-230301 Q.C. - Insert Plate Assy. (N2O)#06-230302 Q.C. - Insert Plate Assy. (Medical air)#06-230303 Q.C. - Insert Plate Assy. (Vac)

14. #06-230056 Dust Cover & Chain Assy. (O2)#06-230057 Dust Cover & Chain Assy. (N2O, Medical air, Vac, N2)

Repair Parts for Series A Outlets areavailable on a limited basis. Outlets requiring obsolete parts canbe updated.

MERCURY MEDICAL® Page 140 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Beacon Medical (Puritan-Bennett) Series “A”

MERCURY MEDICAL® Page 141 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

500 SERIES

Quick Connect Model

Description 1. 6” copper tube connection to medical

gas or vacuum supply line.2. Swivel base housing3. Back box

(Field replacement of items 1, 2and 3 is not feasible).

4. Secondary check kit (6 pk):A. Secondary checkB. Washer C. HousingD. Deflator spring assembly

5. Housing base O-Ring (12/pk)6. Poppet7. Poppet O-Ring(12/pk)8. Valve body assemblies (poppet and O-Rings)

Valve body with poppet pressureValve body with poppet vacuum Valve body with poppet pressure (4 pk)

9. Valve body O-ring (12/pk)10. Face plate assemblies:

OxygenNitrous OxideVacuumMedical AirWAGD (Evacuation) CO2O2/CO2

11. Latch spring kit (12 pk)12. Faceplate mounting

screw kit (48/pk)13. Vacuum spring kit (6/pk)14. Test plug kit (12pk) 15. Back box mounting screw/fastener kit (24pk)

D.I.S.S. Model

Description 16. D.I.S.S. poppet all service except

Oxygen, vacuum, evacuation17. D.I.S.S. poppet oxygen, vacuum,

evacuation18. D.I.S.S. valve body, key ring and poppet assembly:

OxygenNitrous OxideVacuumMedical AirWAGD (Evacuation) N2CO2O2/CO2

19. D.I.S.S. Face Plate Assemblies:OxygenNitrous Oxide

VacuumMedical AirWAGD (Evacuation) N2CO2O2/CO2

20. D.I.S.S. face plate screw kit(24/pk).

21. D.I.S.S. dust cap and chain assembly:OxygenNitrous OxideVacuumMedical Air

22. D.I.S.S. poppet O-Ring only

Item Number

#32-64-90-0650

#32-64-90-0185#32-98-90-0002#32-64-90-0097

#32-64-90-0620#32-64-90-0621#32-64-90-0653#32-64-90-0186

#32-64-91-1501#32-64-91-1504#32-64-91-1502#32-64-91-1503#32-64-91-1506#32-64-91-1507#32-64-91-1508#32-64-90-0096#32-64-90-0031

#32-64-90-0034#32-64-90-0651#32-64-90-0652

Item Number#32-64-90-0029

#32-64-90-0028

#32-64-90-0631#32-64-90-0633#32-64-90-0632#32-64-90-0634#32-64-90-0638#32-64-90-0636#32-64-90-0635#32-64-90-0637

#32-64-91-1561#32-64-91-1564#32-64-91-1562#32-64-91-1563#32-64-91-1566#32-64-91-1565#32-64-91-1567#32-64-91-1568#32-64-90-0030

#32-64-90-0098 6/Pk#32-64-90-0100 6/Pk#32-64-90-0099 6/Pk#32-64-90-0101 6/Pk#32-34-90-0026 12/Pk

Figure #2 - Operation

Figure #1 - Initial Setting

Lightly lubricated* O-Ring shown loadedaround rod and in installer assembly cavity.

Slide bracket assembly up or down untilrod lines up with center of poppet.

#32-64-90-2060 O-Ring installation tool only*Medical Gas Outlet Lubrication (1 ox.) #32-64-90-2111

Gas Outlets/Breakdowns/Chemetron (NCG)

MERCURY MEDICAL® Page 142 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

348, 378, 400 Series

348 Series 378 Series 400 Series

Description Item Number

1. 6” Copper tube for connection N/Ato gas or vacuum supply line

2. Mounting Box N/A3. Back box

(Field replacement of items 1,2 N/Aand 3 are not feasible)

4. Mounting block O-ring #32-64-90-0185 12/Pk5. Secondary check valve #32-64-90-0151* 6/Pk6. Secondary check washer #32-64-90-0107 12/Pk7. Housing #32-64-90-0002 8. Housing O-Ring #32-64-90-0185 12/Pk9. Secondary check spring #32-64-90-0151* 6/Pk

10. Vacuum Spring #32-64-90-0034 6/Pk 11. Test Plug #32-64-90-0001 6/Pk12. Poppet #32-98-90-0002 13. Poppet O-Ring #32-64-90-0097 12/Pk14. Valve body, #32-64-90-0039 12/Pk

Quick-connect (Pressure without poppet)Valve body, #32-64-90-0040 Quick-connect (Vacuum without poppet)Valve body assembly, #32-64-90-0180 (Pressure,Quick-connect with poppet)Valve body assembly, #32-64-90-0181 (Vacuum,Quick-connect with poppet)

15. Valve body O-Ring #32-64-90-0186 12/Pk

*Chemetron Outlet Stations manufactured with rear entry of pigtail (1) use Secondary Check Valve Catalog No. #32-64-90- 0152 Items 5 & 9 make up kit, 6 kits/pk

Description Item Number Description Item Number

16. Face plate springs #32-64-90-0096 12/Pk17. Latch button (indicia) #32-64-90-0003 6/Pk

378, 400 series only (Oxygen)#32-64-90-0004 6/Pk(Vacuum)#32-64-90-0005 6/Pk(Medical air)#32-64-90-0006 6/Pk

(Nitrous Oxide)348 Series Only #32-64-90-0009 6/Pk

(Oxygen)#32-64-90-0155 6/Pk

(Vacuum)#32-64-90-0011 (Medical air) 6/Pk#32-64-90-0012 6/Pk

(Nitrous Oxide)18. Face Plate - 400 Series

#32-64-92-0176 (Oxygen)#32-64-92-0177 (Vacuum)#32-64-92-0178 (Medical air)#32-64-91-4003 (Nitrous Oxide)#32-64-91-4015 (Carbon Dioxide)#32-64-91-4020 (Oxygen/CO2)#32-64-91-4021 WAGD (Evac.)

Ceiling Column Faceplate #32-83-90-4021 WAGD (Evac.)19. Face plate screws #32-64-90-0031 48/Pk20. Poppet #32-64-90-0028(Oxygen and vacuum)21. Poppet #32-64-90-0029(N2O, Medical air, CO2)22. Poppet O-Ring, D.I.S.S #32-34-90-0026 12/Pk23. Valve Body #32-64-90-0157 (Oxygen)

#32-64-90-0078 (Vacuum)#32-64-90-0079 (Nitrous Oxide)#32-64-90-0080 (Medical air)

24. Face Plate -460 Series#32-64-91-6001(Oxygen)#32-64-91-6002(Vacuum)#32-64-91-6004(Medical air)#32-64-90-6003(Nitrous oxide)

25. Latch Button #32-64-90-0020 (Oxygen) 6/Pk#32-64-90-0021(Vacuum) 6/Pk#32-64-90-0022

(Medical air) 6/Pk#32-64-90-0023

(Nitrous Oxide) 6/Pk26. Face plate screws

#32-64-90-0030 24/Pk

27. Dust cap and chain#32-64-90-0098

(Oxygen) 6/Pk#32-64-90-0099

(Vacuum) 6/Pk#32-64-90-0100

(Nitrous Oxide)6/Pk

#32-64-90-0101(Medical air) 6/Pk

28. O-Ring Kit. #32-98-90-0003(Consists of12 each. of items 4, 13, 15)

Quick Connect

D.I.S.S.

Gas Outlets/Breakdowns/Chemetron (NCG)

(Discontinued)

MERCURY MEDICAL® Page 143 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

07 (O.E.S.) SERIES QUICK CONNECT

Repair components are limited. Existing outlets may bemodernized/converted from the detailed list below. Allconversions require additional purchase of drill indexingtemplate(s) for each gas.

Modernizations/Conversions(Requires use of drill indexing template)

‘07 SERIES Q.C. & D.I.S.S. TO Med*Star D.I.S.S.Item Number Description#21-2227-H Oxygen (Template not included)#21-2227-J Vacuum (Template not included)#21-2227-K Nitrous Oxide (Template not included)#21-2227-M Nitrogen (Template not included)#21-2227-L Medical air (Template not included)

‘07 SERIES Q.C. & D.I.S.S. TO Med*Star Q.C.#21-1227-C Oxygen (Template not included)#21-1327-C Vacuum (Template not included)#21-1427-C Nitrous Oxide (Template not included)#21-1527-C Medical air (Template not included)

(Nitrogen not Available)

Med*Star Drill Indexing Templates

Must be used when changing ‘07 Series to Med*Star

#21-1227-G Oxygen, drill indexing template#21-1327-G Vacuum, drill indexing template#21-1427-G Nitrous Oxide, drill indexing template#21-1527-G Medical air, drill indexing template#21-1627-G Nitrogen, drill indexing template

Med*Star QUICK-CONNECTCOMPONENT IDENTIFICATION

Med*Star® D.I.S.S.COMPONENT IDENTIFICATION

Detail No. Description Item Number1. Coverplate Screw 24/PK #21-1207-150-RPL2. Coverplate

Tapered side #21-1227-PStraight #21-2027-X

4. Depth Spacer #21-1207-1725. Camplate Assembly 5/PK #21-1227-M-RPL6. Molded Dust Cover #21-1227-417. Color-coded Pin-Indexed Tumbler

oxygen #21-1207-162nitrous oxide #21-1407-62medical air #21-1507-62vacuum #21-1307-62

8. Seat Washer #21-1217-109. Slide Valve #21-1207-69

10. Slide Valve Springpressure #21-1207-67vacuum #21-1307-12

11.+ Ball Check Retainer Bushing #21-1227-Wwith Seal

12.+ Ball Check #21-3727-1010.+ Ball Check Spring #21-1207-6713. Outlet Body N/A

+ Not used in vacuum outlets.++ Not used on ceiling outlets.

Detail No. Description Item Number1. Coverplate Screw #21-1207-1502.++ Dust Cap and chain

Oxygen #21-1218-AAll others #21-1218-T

3. Coverplatetapered side #21-2227-Pstraight side #21-2227-X

4. Depth Spacer #21-2227-175. Color-coded Pin Indexed Tumbler

oxygen #21-2227-Anitrous oxide #21-2227-Cmedical air #21-2227-Dvacuum #21-2227-Bnitrogen #21-2227-E

6. Depressor Tubeoxygen (1-3/4-44.45mm) #21-2207-12all others (1- 5/8-41.275mm) #21-2227-16

7. Seat Washer #21-1217-108. Slide Valve #21-1207-699. Slide Valve Spring

pressure #21-1207-67vacuum #21-1307-12

10.+ Ball check Retainer BushingWith seal #21-1227-W

11.+ Ball Check #21-3727-109.+ Ball Check Spring #21-1207-67

12. Outlet Body N/A

+ Not used in vacuum outlets.++ Not used on ceiling outlets.

A. Pressure Outlet Slide #21-1227-YValve Assembly

B. Pressure Outlet Internal #21-1227-XParts Kit

A. Pressure Outlet Slide #21-1227-YValve Assembly

B. Pressure Outlet Internal #21-1227-XParts Kit

Description Item Number Description Item Number

1. Coverplate Screw 21-1207-150 7. Seat Washer 21-1217-102. Coverplate 8. Slide Valve 21-1207-69

Oxygen 21-1207-B 9. Slide Valve SpringNitrous Oxide 21-1407-B pressure 21-1207-67Medical Air 21-1507-B vacuum 21-1307-12Vacuum 21-1307-B 10.+ Ball Check Retainer

3. Overhang Spacer 21-1207-37 Bushing 21-1207-644. Depth Spacer 21-1207-35 11.+ Ball Check “O” Ring 21-1247-115. Camplate Assembly 21-1207-M 12.+ Ball Check 21-3727-106. Seat Retainer Bushing 13.+ Ball Check Spring 21-1207-66

Oxygen 21-1207-11 14. Outlet BodyNitrous Oxide 21-1407-11Medical Air 21-1507-11Vacuum 21-1307-11

Parts for 07 Series are available on a limited basis.

1 2 1 4 5 6 7 8 9 10 11 12 10 13

BA

1 2 3 1 4 5 6 7 8 9 10 11 9 12

B

A

Gas Outlets/Breakdowns/Oxequip

MERCURY MEDICAL® Page 144 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Converts Most Quick ConnectStyle Outlets to D.I.S.S. (Screw-On)

FeaturesThe Frontal D.I.S.S. medical gas conversion outletsrepresent the most technically advanced means ofproviding medical gas connections to the centralpiping system.

• Unique patented valve cartridge.• Gas specific D.I.S.S. outlet body.• Double permanent identification for the user -

service identified on both connector and faceplate.• Full faceplate color coding.• Strength of connections eliminates unintended

disconnects.• Provides support for dispensing equipment

without the use of additional brackets.

Specifications

The medical gas wall outlet shall be Frontal D.I.S.S.Medical Gas Outlets. The outlets shall incorporatefull faceplate sized color coding.

The outlets shall be capable of supporting dispensing equipment without the use of slidebrackets.

The medical gas outlets shall be designed so thatonce installed, routine service of both the primaryand secondary check valves can be accomplishedwithout removing the nameplate or gas specificpositions. The primary check valve shall be unitizedand of the cartridge type and the primary check canbe removed for service without shutting off the gas.

The outlet name plate shall be permanently color coded andsealed behind a lexan protective cover. To prevent leakswithin the finished wall, there shall be no rubber o-rings for agas seal behind the faceplate. The name of the gas serviceshall be permanently embossed on the outlet sub-mountingplate and the chrome plated brass outlet body.

Medical gas outlets shall be cleaned for oxygen service inaccordance with the current Compressed Gas Association(CGA) Pamphlet G-4.1, capped and placed in a protectivecontainer for shipment.

The outlets shall be installed in strict accordance withmanufacturer’s instructions, and tested before use inconformance with local and federal codes.

NTALF

Gas Outlets/Conversion Kits

MERCURY MEDICAL® Page 145 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Chemetron/NCG5/8-27Chemetron/NCG3/4-16w/ FlangeMelco/Foregger/Linde9/16-18Ohmeda DiamondSeries 1Ohmeda DiamondSeries II/IIIOhmeda 40 SeriesOxequip 075/8-24Oxequip Med*Star5/8-27Oxequip Med*Star(smooth bore)Puritan Series 735/8-24Puritan Litharge1/4 NPTPuritan Series A (not threaded)PuritanSeries BSchrader1/4 NPTSchrader 5/8-24Schrader5/8-27

#GP-F3816

#GP-F3916

#GP-F3116

#GP-F4016

#GP-F4116

#GP-F4216

#GP-F3216

#GP-F3616

#GP-F3716

#GP-F3316

#GP-F3416

#GP-F3516

#GP-F4616

#GP-F4316

#GP-F4416

#GP-F4516

#GP-F3112

#GP-F3212

#GP-F3612

#GP-F3712

#GP-F3804

#GP-F3904

#GP-F3104

#GP-F4004

#GP-F4104

#GP-F4204

#GP-F3204

#GP-F3604

#GP-F3704

#GP-F3304

#GP-F3404

#GP-F3504

#GP-F4604

#GP-F4304

#GP-F4404

#GP-F4504

#GP-F3824A

#GP-F3924A

#GP-F3124A

#GP-F4024A

#GP-F4124A

#GP-F4224A

#GP-F3224A

#GP-F3624A

#GP-F3724A

#GP-F3324A

#GP-F3424A

#GP-F3524A

#GP-F4624A

#GP-F4324A

#GP-F4424A

#GP-F4524A

#GP-F3822

#GP-F3922

#GP-F3122

#GP-F4022

#GP-F4122

#GP-F4222

#GP-F3222

#GP-F3622

#GP-F3722

#GP-F3322

#GP-F3422

#GP-F3522

#GP-F4622

#GP-F4322

#GP-F4422

#GP-F4522

Item Number Medical Air Nitrogen Nitrous Oxide Oxygen VacuumStandard Conversion Outlets*

* Trim plates are available for multiple outlets and can be installed against the wall behind the outlet faceplate. Trim plates are custom-made based on the distance between outlet centers.

Gas Outlets/Conversion Kits

MERCURY MEDICAL® Page 146 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Valve Body/O-Ring Identification Chart (Chemetron Outlets)

Shown below are actual size drawings of these parts. Check the drawing to verify your catalog number.

INSTALLATION TOOL#32-65-10-1001

1. 2. 3. 4.

Gas Outlets/Conversion Kits/Chemetron (NCG)

MERCURY MEDICAL® Page 147 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

CONVERT FROMPURITAN-BENNETT OUTLETS PURITAN BENNETT

SERIES 73 Outlet

Remove and discardQuick connectvalve

Wall Surface

Wall Surface Keyed

HousingQuick connectValve

Stainless Steel Trimplate

Plastic InsertSome new Puritan Outlets have akeyed housing ring that is partiallyriveted to the base. This rivet mustbe drilled out before removal canproceed. Most housing rings areattached by two screws.

Plastic PlateW/Stainless Inserts

Remove AndDiscard

NOTE:EARLY PURITAN OUTLETS USEDLITHARGE (combination of white lead andglycerin). To secure the Quick-Connect Valveto the Outlet Block. Use of mild heat isrecommended to loosen this connection.

LITHARGEDCONNECTION

Puritan-Bennett Outletwith Litharged Connection

WALLSURFACE

SPRING ANDPOPPET

Quick connect Valve RemoveandDiscard

STAINLESSSTEEL

ActuatorSpring

Adapter HousingSelect Pop Rivetto match Depthof Box

Base Housing Valve BodyKeyed Per Service

Back Spacer Plate

Stainless Steel Plate

Quick Connect LatchMechanismNOTE: Poppet and Brass Check

Bushing must be in position for properfunction.

SINGLE WALL OUTLETINSTALLATION

Oxygen #32-65120101Vacuum #32-65120102Medical Air #32-65120104Nitrous #32-65120103Oxide

1” Long Screwsprovided

Spacing determines proper Puritan conversionfor multi-gang outlets

MULTIPLE WALL OUTLETINSTALLATION

Oxygen #32-65120501Vacuum #32-65120502Medical Air #32-65120504

Gas Outlets/Conversion Kits/Chemetron (NCG)

MERCURY MEDICAL® Page 148 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Catalog Gas IncludesNumber Service Valve Body Center-to-Center

Assembly Measurement#32-49100001 Oxygen NO NA#32-49100002 Vacuum NO NA#32-49100003 Medical air NO NA#32-49100004 Vac/Oxy NO 1 13/16” (4.60cm)#32-49100005 Oxy/Vac NO 3 5/8” (9.21 cm)#32-49100006 Vac/Medical air NO 3 5/8” (9.21 cm)#32-49100007 Vac/Oxy NO 3 5/8” (9.21 cm)#32-49100009 Oxy/Medical air Yes 3 5/8” (9.21 cm)#32-49100012 Vacuum Yes NA#32-49100013 Nitrous Oxide Yes NA#32-49100014 Medical air Yes NA#32-49100016 Oxy/Vac Yes 3 5/8” (9.21 cm)#32-49100020 Vac/Vac NO 1 13/16” (4.60cm)#32-49100021 Oxy/Vac/Medical air NO 1 13/16” (4.60cm)#32-49100036 Oxygen Yes NA#32-49100038 Vac/Oxy Yes 1 13/16” (4.60cm)#32-49100040 Vac/Oxy Yes 3 5/8” (9.21cm)#32-49100041 Vac/Medical air Yes 3 5/8” (9.21cm)#32-49100042 Centron Oxy Yes NA#32-49100043 Centron Vac Yes NA#32-49100044 Vac/Oxy/Vac Yes 1 13/16” (4.60cm)#32-49100045 Oxy/Medical air/Vac Yes 1 13/16” (4.60cm)#32-49100047 Oxy/N2O/Medical air Yes 1 13/16” (4.60cm)

/Vac#32-49100050 Medical air/Medical air Yes 1 13/16” (4.60cm)#32-49100055 Vac/N2O/Oxy Yes 1 13/16” (4.60cm)#32-49100057 Oxy/Vac Yes 1 13/16” (4.60cm)#32-49100058 Oxy/N2O/Vac Yes 1 13/16” (4.60cm)

When ordering multiple service Modernization Kits adetermination of the distance between gas service isimportant. The center-to-center measurement represents thedistance between vertical, imaginary line extendingthrough the center of the poppet or gas opening.The distance between gas service is often referred to asa “Blank.” The center-to-center measurement betweenoxygen and vacuum, for example, on an outlet with no“BLANKS” is 1-13/16”. Multiple outlets with one “BLANK”between gas services have a 3-5/8” distance. Outletshaving a 5-7/16” center-to-center measurement wouldhave two “BLANKS” between gas service.NOTE: State gas service reading left to right as you lookat the face plate. In the photo above, the sequence forordering purposes is Oxygen-B-B-Air-B-B-Vac (B=Blank).For ease of Identification, Modernization Kits aregrouped by single or multiple gas service and with orwithout valve body assembly.

Economical ...Easy to do!Chemetron modernization kits are availablefor updating of outlets in walls, patientbedside consoles, prefabricated modular wallsystems, ceiling columns as well as forVacpak respiratory and suction servicecabinets. And this updating can be done asthe need arises, and/or time permits. Theyhave an attractive stainless steel fascia with asatin finish. The fascia has a color coded tabfor easy release of secondary equipment. It isalso safety-keyed by gas service to theexisting back box.The number of parts and assembly has beensimplified since a rugged latching mechanismis now part of the fascia assembly. Many kitsare available with a complete valve bodyassembly offering improved flowcharacteristics. The modernization kits aredesigned to allow hospital maintenancepersonnel to easily and economically updateolder version NCG outlets and enjoy all thebenefits of the new, simplified 400 SeriesOutlet. The following illustrates the ease withwhich this updating can be carried out.

STEP 1

a. Remove and discard cover screws and old cover plate.

b. Remove and discard stabilizer screws andand stabilizer, if applicable.

c. Remove and discard latch screws and latch(except on 148 series).

d. Remove valve body assembly if it is to be replaced with a new valve body assembly.

STEP 2

a. Mount conversion guard to outlet box with tamper-proof screws as illustrated. The gas service is stamped into the conversion guardfor identification.CAUTION: Extreme care must be takento ensure that the Conversion Guardincluded with the kit is used for thespecific gas service for which it isintended. This is necessary to avoid thepossibility of interchanging gases.

b. Insert new valve body assembly (if applicable).

c. Attach 400 Series fascia. The protruding “Keys” affixed to the fascia must match the “Keyhole Slots” in the conversion guard.It may be necessary to adjust the valvebodies inward or outward for optimum fasciafit.Matching of “Key” and “Slot” recognizeimportance of matching gas services. Donot rely on pipe decals- confirm outflow!

Extended Barrel is a special Valve Body or Face-plate. Always Modernize with a new valve body.

Gas Outlets/Modernization Kits/Accessories

MERCURY MEDICAL® Page 149 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Catalog Gas IncludesNumber Service Valve Body Center-to-Center

Assembly Measurement#32-49110001 Oxygen NO NA#32-49110002 Vacuum NO NA#32-49110004 Oxy/Vac Yes 3 5/8”(9.21cm)#32-49110006 Oxygen Yes NA#32-49110007 Vacuum Yes NA#32-49110008 Nitrous Oxide Yes NA#32-49110009 Medical air Yes NA#32-49110010 Oxy/Vac Yes 3 5/8” (9.21 cm)#32-49110011 Oxy/Vac Yes 5 7/16” (13.81 cm)#32-49110015 Medical air NO NA#32-49110016 Vac/Oxy NO 3 5/8” (9.21 cm)#32-49110017 Oxy/Oxy Yes 3 5/8” (9.21 cm)#32-49110019 Oxy/N2O/Vac NO 1 13/16” (4.60cm)#32-49110023 Oxy/Medical air/Vac Yes 1 13/16” (4.60cm)#32-49110033 Palco console Yes NA

Oxy#32-49110037 Auth console Yes NA

Oxy#32-49110045 Oxy/N2O/Medical air Yes 1 13/16” (4.60cm)#32-49110046 Vac/Medical air/Oxy Yes 1 13/16” (4.60cm)#32-49110047 Vac/N2O/Oxy Yes 1 13/16” (4.60cm)#32-49110048 Vac/Oxy Yes 3 5/8” (9.21 cm)#32-49110049 Vac/Oxy/Vac Yes 5 7/16”(13.81 cm)#32-49110054 Oxy/Vac/Vac Yes 1 13/16” (4.60cm)

246 SERIES (Not Shown)

Catalog Gas Includes Center To Number Service Valve Body Center

Assembly Measurement#32-49170001 Oxygen Yes NA#32-49170002 Vacuum Yes NA#32-49170003 Nitrous Oxide Yes NA#32-49170004 Medical air Yes NA

Catalog Gas IncludesNumber Service Valve Body Center-to-Center

Assembly Measurement#32-49120001 Oxygen NO NA#32-49120002 Vacuum NO NA#32-49120004 Oxy/Vac NO 5 7/16”(13.81 cm)#32-49120005 Medical air NO NA#32-49120006 Oxygen Yes NA#32-49120007 Vacuum Yes NA#32-49120008 Nitrous Oxide Yes NA#32-49120009 Medical air Yes NA#32-49120010 Oxy/Vac Yes 3 5/8” (9.21 cm)#32-49120011 Oxy/Vac Yes 5 7/16” (13.81 cm)#32-49120012 Vac/Oxy Yes 3 5/8” (9.21 cm)#32-49120015 Oxy/N2O Yes 3 5/8” (9.21 cm)#32-49120016 Vac/Oxy NO 1 13/16” (4.60cm)#32-49120017 Oxy/Vac NO 3 5/8” (9.21 cm)#32-49120020 Oxy/Medical air/Vac Yes 1 13/16” (4.60cm)#32-49120023 Oxy/N2O NO 3 5/8” (9.21 cm)#32-49120024 Vac/Vac NO 3 5/8” (9.21 cm)#32-49120040 Vac/Oxy Yes 1 13/16” (4.60cm)

146 SERIES (Not Shown)

Catalog Gas IncludesNumber Service Valve Body Center-to-Center

Assembly Measurement#32-49160001 Oxygen Yes NA#32-49160002 Vacuum Yes NA#32-49160003 Nitrous Oxide Yes NA

236 Series (Not Shown)

Catalog Gas Includes Number Service Gas Body Center-to-Center

Assembly Measurement#32-49180001 Oxygen Yes NA#32-49180002 Vacuum Yes NA

248 Valve Body 148 Valve Body1 5/8” 1 1/8”

SealSurfaceArea

SealSurfaceArea

Notch

248 Series Outlets 148 Series Outlets

248 Series 148 Series

Gas Outlets/Modernization Kits/Chemetron

MERCURY MEDICAL® Page 150 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

The performance and operation of the earlierseries of Nellcor Puritan BennettTM (nowBeacon Medical) outlets can be improved byinstalling a Series B Upgrade Kit. NellcorPuritan-Bennett outlets are identified by designconfigurations applicable to each of the threeoutlet series; Litharge, Series 73 and Series A.The complete upgrade kit consists of threecomponent assemblies: 1) a gas servicespecific outlet valve, 2) a coverplate, andstandoff for either 3-1/4” or 5” centerline spaceoutlets and 3) a connector for either litharge,Series 73, or series A outlets.

An upgrade program begins with an inventory ofthe outlet series to be upgraded. The illustrationbelow will aid in identifying the outlet series forordering the correct upgrade kit. Outlets are bestidentified by the design of the outlet block.Removal of the coverplate may be necessary tobe certain the correct connector is ordered.

Outlet Identification and Upgrade ComponentsUpdate Kits, Item #1, on the following page are used with all outlet series types. Connectors, Items # 2, #3, and #4 are used with specific series types. Coverplates and standoffs, Items #5 through #8are also used with specific series types. Figure 1 below shows key identification components of threeoutlet series types while Figure 2 shows the appropriate upgrade components.

Gas Outlets/Modernization Kits/Puritan-Bennett/Beacon Medaes

MERCURY MEDICAL® Page 151 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Parts List

Item Number DescriptionNellcor Puritan-Bennett Series “B” D.I.S.S. outlet Upgrade Kit

#06-232200-00 Oxygen (U.S. labeling)#06-232201-00 Nitrous Oxide (U.S. &

International labeling)#06-232202-00 Medical air (U.S. labeling)#06-232203-00 Vacuum (U.S. labeling)#06-232209-00 Evacuation ( U.S. and

International labeling)#06-232210-00 Oxygen ( International

labeling)#06-232212-00 Medical air (International labeling)#06-232213-00 Vacuum (International labeling)

Nellcor Puritan-Bennett Series “B” quick-connect Outlet Upgrade Kit

#06-232020-00 Oxygen (U.S. labeling)#06-232021-00 Nitrous Oxide (U.S. and

International labeling)#06-232022-00 Medical air (U.S. labeling)#06-232023-00 Vacuum (U.S. labeling)#06-232024-00 Evacuation (U.S. and International

labeling)#06-232025-00 Oxygen (International labeling)#06-232027-00 Medical air (International labeling)#06-232028-00 Vacuum (International labeling)

Item Number Description1a. #06-232029-00 Series B slide upgrade kit2. #06-232034-00 Connector (litharged outlets)3. #06-232033-00 Connector (series ‘73 outlets)4. #06-232032-00 Connector (series A outlets)5. #06-325149-00 Coverplate (5” centerline)6. #06-325148-00 Coverplate (3-1/4” centerline)7. #06-315014-00 Standoff (5” centerline)8. #06-315013-00 Standoff (3-1/4” centerline)9. #06-232031-00 Adapter nut assembly (buried

outlets)

Tools and Service Materials• Heat gun - 400 watt (litharged outlets)• Teflon® tape (litharged outlets)• Truarc retaining ring pliers• 1/4” pipe thread tap (litharged outlets)• Oxygen compatible leak detector solution• Staked connector replacement tool kit

(P/N #06-138024-00, Series 73 outlets)• Phillips head screwdriver• 5/16” open end wrench• 7/8” socket wrench• 11/16” socket wrench• Pop rivet tool • Measuring scale• No. 30 drill• Pliers• Vacuum cleaner (portable)

Gas Outlets/Modernization Kits/Puritan-Bennett/Beacon Medaes

MERCURY MEDICAL® Page 152 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Order This Now Item Number Contents Allows for Service or RepairSTARTER

REPAIR KIT

PARTS KITSOrder now or later

Quick connect 400Series Outlet StationParts Kit

D.I.S.S. Outlet 460Series Station PartsKit

Quick-Connect 500Series Outlet Station Parts Kit

High Pressure Nitrogen OutletStation Parts Kit

#32-64-90-2023

#32-64-90-2001

#32-64-90-2002

#32-64-90-2005

#32-64-90-2004

Carrying case, labeled Common PartsKit, O-Ring lubricant, O-Ring ServiceTool, and space for Parts listed below.

Provides you with Labeled OrganizerKit Box, valve bodies, poppets, latchtips and buttons, latch springs.

Labeled Organizer Kit Box, valve bodies for most commonly used gasservices, poppets, dust caps, gasservice buttons and screws.

Labeled Organizer Kit Box, secondarycheck poppets, tool, valve bodies,springs.

Labeled Organizer Kit Box, Dyna-Convalve assemblies, housings, Dyna-Conservice tool, knobs, lock washers, O-rings and seals.

O-Rings for all Chemetron (NCG®) QuickConnect and D.I.S.S. outlet stations;Base Housings, vacuum springs, andsecondary checks for 348/346, 378/376and 400/460 series outlets.

Allows you to service or repairSeries348, 378, and 400 Quick-Connectstation valves and faceplates.

Series 346, 376, and 460 D.I.S.S. outletstation valves and faceplates.

Series 500 Quick-Connect outletstations.

Chemetron (NCG) high-pressureDynaCon outlet station valves fornitrogen service.

METHOD ONE

METHOD TWOOrder This Now

COMPLETEREPAIR KIT

Item Number

#32-64-90-2028

Contents

Starter Repair kitQuick Connect partsD.I.S.S. Parts kitHigh Pressure Parts Kit

Repair Service

All of the outlet Stationslisted above except 500and 560 series outlets.

KIT BREAKDOWNSQuick Connect #32-64-90-2001

Item Number Description Quantity#32-64-90-0096 Spring 24#32-64-90-0031 Screw 48#32-64-90-0204 Valve 12#32-64-90-0002 Poppet 24#32-64-90-0011 Air Tip 6#32-64-90-0155 Vac Tip 6#32-64-90-0009 O2 Tip 6#32-64-90-0012 N2O Tip 6#32-64-90-0006 N2O Button 6#32-64-90-0003 O2 Button 6#32-64-90-0005 Air Button 6

Nitrogen Kit #32-64-90-2004#32-11-90-0013 Housing 2#32-11-91-0178 Installation Tool 1#32-64-90-0120 O-Ring 12#32-11-91-0176 O-Ring 12#32-11-91-0179 Dynacon Assy. 2#32-11-20-0011 Knob 2#32-64-90-0194 N2 Button 6

Outlet Station Repair Kit - Complete #32-64-90-2028#32-64-90-2004 N2 Kit 1#32-64-90-2001 Quick Connect Kit 1#32-64-90-2002 D.I.S.S. Kit 1#32-64-90-2023 Common Parts Kit 1

Common parts #32-64-90-2023

Item Number Description Quantity#32-64-90-0002 Housing 8#32-64-90-0034 Spring 12#32-64-90-0001 Test Plug 6#32-64-90-0151 Secondary Check 24#32-64-90-0107 Washer 50#32-64-90-0185 O-Ring 100#32-64-90-0186 O-Ring 100#32-64-90-0097 O-Ring 100#32-64-90-2060 O-Ring Tool 1#32-64-90-2071 Socket 1#32-64-90-2072 O-Ring Pick 1#32-64-90-2111 Lube 1D.I.S.S. KIT #32-64-90-2002Item Number Description Quantity#32-64-90-0157 O2 valve body 4#32-64-90-0079 N2O valve body 2#32-64-90-0078 Vac Valve Body 4#32-64-90-0080 Air Valve Body 2#32-64-90-0028 Poppet 12#32-64-90-0029 Poppet 12 #32-64-90-0182 Screw 48#32-64-90-0020 O2 Button 6#32-64-90-0021 Vac Button 6#32-64-90-0023 N2O Button 4#32-64-90-0022 Air Button 6#32-64-90-0098 O2 Cap 6#32-64-90-0099 Vac Cap 6#32-64-90-0101 Air Cap 6#32-64-90-0100 N2O Cap 4

Gas Outlets/Repair Kits/Chemetron (NCG)

MERCURY MEDICAL® Page 153 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Gas Outlets/Ball Valves

MERCURY MEDICAL® Page 154 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

WITHOUT EXTENSIONS#69-250-20 1/2” (13mm) All valves are rated at 400 PSIG#69-250-21 3/4” (19mm) and are prepared for Oxygen service.#69-250-22 1” (25mm) Operation from “ON” to full#69-250-23 1-1/4” (32mm) “Off” by simple 90o turn of valve handle.#69-250-24 1-1/2” (38mm)#69-250-25 2” (51mm)

WITH EXTENSIONS (including gauge ports - 1/8” Fe)

#32-77030002 1/2”#32-77030003 3/4”#32-77030004 1”#32-77030005 1-1/4”#32-77030006 1-1/2”#32-77030008 2”

BALL VALVE LOCK HANDLEItem Number Valve Size

#32-77-03-9206 1/2” to 3/4”#32-77-03-9207 1” & 1-1/4”#32-77-03-9208 1-1/2” & 2”

GAUGES#32-77-900571 0-100 PSI Pressure#32-77-900572 0-30” Hg Vacuum#32-77-900573 0-300 PSI Pressure (Nitrogen)

VAC. GASEVAC.

N2O AIR O2

PHOTO FOR REFERENCE ONLY

Actual labels are NFPA compliant

Pipeline LabelsAMPPLAB4X3AIR PIPELINE LABEL AIR 500/RLAMPPLAB4X3CO2 PIPELINE LABEL CO2 500/RLAMPPLAB4X3EVAC PIPELINE LABEL EVAC 500/RLAMPPLAB4X3N2 PIPELINE LABEL N2 500/RLAMPPLAB4X3N2O PIPELINE LABEL N2O 500/RLAMPPLAB4X3OXY PIPELINE LABEL OXYGEN 500/RLAMPPLAB4X3VAC PIPELINE LABEL VACUUM 500/RL

Gas Outlets/Ball Valves

MERCURY MEDICAL® Page 155 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375

Product BenefitsAmvex Integrated Flowmeter outlet combines a Dial Flowmeter and a Medical Gas Outlet into a singlecompact design. The right side port connection has a control knob which allows the user to adjust the flowsetting, while the left side port is a direct connection to the gas supply.The Amvex Integrated Flowmeter saves space, reduces construction costs, and ensures healthcareproviders always have a Flowmeter when they need one.

• Easy to read and determine flow levels• Solid construction and streamlined design• Flow Indicator ball indicates that gas is being delivered• Safest, most convenient way to dispense Oxygen & Medical Air• Minimizes cross contamination• No more lost, chained, or broken Flowmeters• Retrofi t existing outlets• Additional outlet can be used for Specialty Flowmeters, Hoses, or a connection for Ventilators

Part Configurator

Ranges available: 0-8 LPM, 0-15 LPM, 0-25 LPMMedical Oxygen and Medical Air

Gas Outlets/Integrated Flowmeter


Recommended