Page 1 Phone: 206-316-2330 or 801-487-8795 Fax: 801-487-8798 Email: [email protected] Website: mountaincontrols.com GC Valves—S21 Series Overview Specifications in this guide: 2-way piloted diaphragm valves Available in normally closed and normally open operation modes 1 to 250 psi Cv to 29 Orifices to 1-1/2” Brass or stainless steel body Buna, EPR, NORYL, Plastic, Teflon, or Viton seals 3/8” to 2” NPT ports S21 Series 3/8” NPT, Brass Body, Normally Closed S21 Series 3/8” NPT, Type 316 SS Body, Normally Closed S21 Series 3/8” NPT, Brass Body, Normally Closed, High Performance H21 Series 3/8” NPT, Brass Body, Normally Closed, High Pressure S21 Series 3/8” NPT, Brass Body, Normally Closed S21 Series 3/8” NPT, Type 316 SS Body, Normally Open S21 Series 3/8” NPT, Brass Body, Normally Open, High Performance S21 Series 1/2” NPT, Brass Body, Normally Closed S21 Series 1/2” NPT, Type 316 SS Body, Normally Closed S21 Series 1/2” NPT, Brass Body, Normally Closed, High Performance H21 Series 1/2” NPT, Brass Body, Normally Closed, High Pressure S21 Series 1/2” NPT, Brass Body, Normally Open S21 Series 1/2” NPT, Type 316 SS Body, Normally Open S21 Series 1/2” NPT, Brass Body, Normally Open, High Performance S21 Series 3/4” NPT, Brass Body, Normally Closed S21 Series 3/4” NPT, Type 316 SS Body, Normally Closed S21 Series 3/4” NPT, Brass Body, Normally Closed, High Performance H21 Series 3/4” NPT, Brass Body, Normally Closed, High Pressure S21 Series 3/4” NPT, Brass Body, Normally Open S21 Series 3/4” NPT, Type 316 SS Body, Normally Open S21 Series 3/4” NPT, Brass Body, Normally Open, High Performance S21 Series 1” NPT, Brass Body, Normally Closed S21 Series 1” NPT, Type 316 SS Body, Normally Closed S21 Series 1” NPT, Brass Body, Normally Closed, High Performance S21 Series 1” NPT, Type 316 SS Body, Normally Closed, High Performance S21 Series 1” NPT, Brass Body, Normally Open S21 Series 1” NPT, Type 316 SS Body, Normally Open Mountain Controls is proud to offer quality solenoid valves from GC valves. The S21 Series features the following:
Transcript
Page 1: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 1

Phone: 206-316-2330 or 801-487-8795Fax: 801-487-8798

Email: [email protected]: mountaincontrols.com

GC Valves—S21 Series Overview

Specifications in this guide:

• 2-way piloted diaphragm valves• Available in normally closed and normally open operation modes• 1 to 250 psi• Cv to 29• Orificesto1-1/2”• Brass or stainless steel body• Buna,EPR,NORYL,Plastic,Teflon,orVitonseals• 3/8”to2”NPTports

• S21Series3/8”NPT,BrassBody,NormallyClosed• S21Series3/8”NPT,Type316SSBody,NormallyClosed• S21Series3/8”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series3/8”NPT,BrassBody,NormallyClosed,HighPressure• S21Series3/8”NPT,BrassBody,NormallyClosed• S21Series3/8”NPT,Type316SSBody,NormallyOpen• S21Series3/8”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1/2”NPT,BrassBody,NormallyClosed• S21Series1/2”NPT,Type316SSBody,NormallyClosed• S21Series1/2”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series1/2”NPT,BrassBody,NormallyClosed,HighPressure• S21Series1/2”NPT,BrassBody,NormallyOpen• S21Series1/2”NPT,Type316SSBody,NormallyOpen• S21Series1/2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series3/4”NPT,BrassBody,NormallyClosed• S21Series3/4”NPT,Type316SSBody,NormallyClosed• S21Series3/4”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series3/4”NPT,BrassBody,NormallyClosed,HighPressure• S21Series3/4”NPT,BrassBody,NormallyOpen• S21Series3/4”NPT,Type316SSBody,NormallyOpen• S21Series3/4”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1”NPT,BrassBody,NormallyClosed• S21Series1”NPT,Type316SSBody,NormallyClosed• S21Series1”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1”NPT,BrassBody,NormallyOpen• S21Series1”NPT,Type316SSBody,NormallyOpen

MountainControlsisproudtoofferqualitysolenoidvalvesfromGCvalves.TheS21Seriesfeaturesthefollowing:

Page 2: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 2

• S21Series1”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series1-1/4”NPT,BrassBody,NormallyClosed• S21Series1-1/4”NPT,Type316SSBody,NormallyClosed• S21Series1-1/4”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1-1/4”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1-1/4”NPT,BrassBody,NormallyOpen• S21Series1-1/4”NPT,Type316SSBody,NormallyOpen• S21Series1-1/4”NPT,BrassBody,NormallyOpen,HighPerformance • S21Series1-1/4”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series1-1/2”NPT,BrassBody,NormallyClosed• S21Series1-1/2”NPT,Type316SSBody,NormallyClosed• S21Series1-1/2”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1-1/2”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1-1/2”NPT,BrassBody,NormallyOpen• S21Series1-1/2”NPT,Type316SSBody,NormallyOpen• S21Series1-1/2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1-1/2”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series2”NPT,BrassBody,NormallyClosed• S21Series2”NPT,Type316SSBody,NormallyClosed• S21Series2”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series2”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series2”NPT,BrassBody,NormallyOpen• S21Series2”NPT,Type316SSBody,NormallyOpen• S21Series2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series2”NPT,Type316SSBody,NormallyOpen,HighPerformance

Page 3: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 3For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/8" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 4: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page4For ordering information, visit mountaincontrols.com.

S211 – 3/8" NPT, Brass Body, Normally Closed

5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5CG4

3/85/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5CG4

5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5CG4

5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5CG4

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

S 2 1 1 G F 0 2 C 5 C G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass C: 3/8” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 5: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 5For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/8" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 6: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page6For ordering information, visit mountaincontrols.com.

S211 – 3/8" NPT, Stainless Steel Body, Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

S 2 1 1 G F 0 2 E 7 C G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS C: 3/8” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7CG4

3/85/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7CG4

5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7CG4

5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7CG4

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 7: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 7For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 3/8" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ± 45º From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Body Code 4 Body Code 2

Page 8: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page8For ordering information, visit mountaincontrols.com.

S211 – High Performance, 3/8" NPT, Brass Body,Normally Closed

S 2 1 1 G F 0 2 K 4 C G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

C: 3/8” NPT

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1/2 3.3 1 250 150 250 150 250 150 — — 230 Viton 8 9 S211GF02K4CG1

3/8 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4CG1

1/2 3.3 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2CG1

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 9: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 9For ordering information, visit mountaincontrols.com.

H21 Series

Dimensions/Weight

- High Pressure- 3/8" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Recognized

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 10: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 10For ordering information, visit mountaincontrols.com.

H211 – High Pressure, 3/8" NPT, Brass Body,Normally Closed

H 2 1 1 G F 0 2 Z 4 C G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

H21 G: Conduit F: Class F 02: 120/60110/50

Z: Viton/Teflon

4: Brass C: 3/8” NPT G1: 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 18 19

Coil Family

Type Size

All S4

3/8 1/2 3.3 10 1400 1400 1400 1400 1400 1400 230 Viton/Teflon 10 10 H211GF02Z4CG1

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

Page 11: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 11For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/8" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 12: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 12For ordering information, visit mountaincontrols.com.

S212 – 3/8" NPT, Brass Body, Normally Open

5/8 3.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5CG4

3/85/8 3.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5CG4

5/8 3.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5CG4

5/8 3.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5CG4

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

S 2 1 2 G F 0 2 C 5 C G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass C: 3/8” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 13: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 13For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/8" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 14: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page14For ordering information, visit mountaincontrols.com.

S212 – 3/8" NPT, Stainless Steel Body, Type 316,Normally Open

5/8 3.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7CG4

3/85/8 3.3 3 250 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7CG4

5/8 3.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7CG4

5/8 3.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7CG4

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

S 2 1 2 G F 0 2 E 7 C G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS C: 3/8” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 15: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 15For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 3/8" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Recognized

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Body Code 4 Body Code 2

Page 16: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page16For ordering information, visit mountaincontrols.com.

S212 – High Performance, 3/8" NPT, Brass Body,Normally Open

S 2 1 2 G F 0 2 K 4 C G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

C: 3/8” NPT G1: 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

All S3

1/2 3.3 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4CG1

3/8 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4CG1

1/2 3.3 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2CG1

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 17: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 17For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 18: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page18For ordering information, visit mountaincontrols.com.

S211 – 1/2" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 D G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass D: 1/2” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5DG4

1/25/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5DG4

5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5DG4

5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5DG4

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 19: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 19For ordering information, visit mountaincontrols.com.

Dimensions/Weight

- 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile , Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

S21 Series

* Not available for all variations

Page 20: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 20For ordering information, visit mountaincontrols.com.

S211 – 1/2" NPT, Stainless Steel Body, Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

S 2 1 1 G F 0 2 E 7 D G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS D: 1/2” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7DG4

1/25/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7DG4

5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7DG4

5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7DG4

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 21: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 21For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ± 45º From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Body Code 4 Body Code 2

Page 22: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 22For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 K 4 D G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

D: 1/2” NPT G1: 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1/2 3.3 1 250 150 250 150 250 150 — — 230 Viton 8 9 S211GF02K4DG1

1/2 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4DG1

1/2 3.6 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2DG1

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1/2" NPT, Brass Body,Normally Closed

Page 23: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 23For ordering information, visit mountaincontrols.com.

H21 Series

Dimensions/Weight

- High Pressure- 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Recognized

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 24: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page24For ordering information, visit mountaincontrols.com.

H211 – High Pressure, 1/2" NPT, Brass Body,Normally Closed

H 2 1 1 G F 0 2 Z 4 D G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

H21 G: Conduit F: Class F 02: 120/60110/50

Z: Viton/Teflon

4: Brass D: 1/2” NPT G1: 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 18 19

Coil Family

Type Size

All S4

1/2 1/2 3.3 10 1400 1400 1400 1400 1400 1400 230 Viton/Teflon 10 10 H211GF02Z4DG1

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )AC DC AC DC AC DC

Air/Gas Water Light Oil

Page 25: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 25For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 26: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page26For ordering information, visit mountaincontrols.com.

S212 – 1/2" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 D G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass D: 1/2” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

5/8 4.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5DG4

1/25/8 4.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5DG4

5/8 4.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5DG4

5/8 4.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5DG4

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 27: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 27For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Page 28: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page28For ordering information, visit mountaincontrols.com.

S212 – 1/2" NPT, Stainless Steel Body, Type 316,Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

S 2 1 2 G F 0 2 E 7 D G 4Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS D: 1/2” NPT G4: 5/8”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

5/8 4.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7DG4

1/25/8 4.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7DG4

5/8 4.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7DG4

5/8 4.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7DG4

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 29: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 29For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

2.5

* Not available for all variations

Body Code 4 Body Code 2

Page 30: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 30For ordering information, visit mountaincontrols.com.

S 2 1 2 G F 0 2 K 4 D G 1Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

D: 1/2” NPT G1: 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

All S3

1/2 3.3 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4DG1

1/2 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4DG1

1/2 3.6 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2DG1

IN °F

Normally Closed

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S212 – High Performance, 1/2" NPT, Brass Body,Normally Open

Page 31: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 31For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Page 32: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 32For ordering information, visit mountaincontrols.com.

S211 – 3/4" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

3/4 6.7 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5EG5

3/43/4 6.7 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5EG5

3/4 6.7 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5EG5

3/4 6.7 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5EG5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 33: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 33For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Page 34: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page34For ordering information, visit mountaincontrols.com.

S211 – 3/4" NPT, Stainless Steel Body, Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

AC S3DC S4

S 2 1 1 G F 0 2 E 7 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

3/4 6.7 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7EG5

3/43/4 6.7 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7EG5

3/4 6.7 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7EG5

3/4 6.7 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7EG5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 35: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 35For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 3/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ± 45º From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Body Code 4 Body Code 2

Page 36: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page36For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 K 4 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

3/4 6.1 1 250 150 250 150 250150 — — 230 Viton 8 9 S211GF02K4EG5

3/4 3/4 6.1 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4EG5

3/4 7.0 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2EG5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 3/4" NPT, Brass Body,Normally Closed

Page 37: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 37For ordering information, visit mountaincontrols.com.

H21 Series

Dimensions/Weight

- High Pressure- 3/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Recognized

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Page 38: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page38For ordering information, visit mountaincontrols.com.

VALVES

H211 - High Pressure, 3/4" NPT, Brass Body, Normally Closed

I Valve Selection List I Normally Closed Energized De-Energized

p

Q) Operating Pressure Differential (psi)

ci. Power Model CodeN MaximumQ) iii E ro N

;','j� Consumption ( 120V/60HZ-110V/50HZ)iii Q) ·� {) E Air/Gas Water Light Oil 2-:, (Watts) Shown � ;;:::: m ·c :::, � 2 a: 0

.�

AC DC AC DC AC DC ro AC DC Brass BodyCv � Q) NPT IN OF (J)

3/4 3/4 6.1 10 400 400 400 400 400 400 230 Viton/Teflor 10 10 H211 G F02Z4EG5

Part Numbering I 1 2 3 4 5 6 7 8 9 10 11 12 13

[HJ�[[] [[] [g] [EJ [Q]� � @] [fil [g][[ Series Operating Housing• Coil Class• Voltage• Seal Body Pipe Orifice SizeMode Material Material Connection

H21 1: Normally G : Conduit F : Class F 02: 120/60 Z : Viton/ 4 : Brass E: 3/4" NPT GS: 3/4"Closed 110/50 Teflon

•See the "Engineering Guide" for additional voltages, variations and options.

I I I I I I

Coil Data I Coil Family Frequency (Hz) 60 50

Type Size

All S4 Nominal Power (VA) Inrush 46 46

Holding 18 19

Page 39: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 39For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Page 40: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page40For ordering information, visit mountaincontrols.com.

S212 – 3/4" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

3/4 6.7 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5EG5

3/43/4 6.7 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5EG5

3/4 6.7 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5EG5

3/4 6.7 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5EG5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 41: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page41For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 3/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Page 42: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page42For ordering information, visit mountaincontrols.com.

S212 – 3/4" NPT, Stainless Steel Body, Type 316,Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

ALL S4

S 2 1 2 G F 0 2 E 7 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

3/4 6.7 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7EG5

3/43/4 6.7 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7EG5

3/4 6.7 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7EG5

3/4 6.7 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7EG5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 43: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page43For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 3/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

3.3

* Not available for all variations

Body Code 4 Body Code 2

Page 44: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page44For ordering information, visit mountaincontrols.com.

S 2 1 2 G F 0 2 K 4 E G 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

K: VitonT: Teflon

4: ForgedBrass

2: Brass

E: 3/4” NPT G5: 3/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

All S3

3/4 6.1 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4EG5

3/4 3/4 6.1 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4EG5

3/4 7.0 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2EG5

IN °F

Normally Closed

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 3/4" NPT, Brass Body,Normally Open

Page 45: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page45For ordering information, visit mountaincontrols.com.

S21 Series

296Dimensions/Weight

- 1" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 46: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page46For ordering information, visit mountaincontrols.com.

S211 – 1" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

1 13 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5FG9

1 13 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02N5FG91

1 13 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02V5FG9

1 13 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5FG9

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 47: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page47For ordering information, visit mountaincontrols.com.

S21 Series

296Dimensions/Weight

- 1" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 48: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page48For ordering information, visit mountaincontrols.com.

S211 – 1" NPT, Stainless Steel Body Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

S 2 1 1 G F 0 2 E 7 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

1 13 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7FG9

1 13 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02J7FG91

1 13 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02L7FG9

1 13 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7FG9

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 49: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page49For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1” - #4 Body; Stainless Steel Ø 1” - #2” Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 50: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 50For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 4 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: Brass2: Brass

F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

11 13 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4FG9

1 13 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2FG9

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1" NPT, Brass Body,Normally Closed

Page 51: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 51For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 52: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 52For ordering information, visit mountaincontrols.com.

S211 – High Performance, 1" NPT, Stainless Steel Body-Type 316, Normally Closed

S 2 1 1 G F 0 2 N 1 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

* Class H Coil Recommended for Steam and Other High Temperature Applications

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

11 13 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1FG9

1 13 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1FG9

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

Page 53: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 53For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 54: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page54For ordering information, visit mountaincontrols.com.

S212 – 1" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

ALL S3

1 13 5 200 140 150 140 — — — — 295 EPR 9 9 S212GF02C5FG9

1 13 5 200 140 150 140 100 100 — — 180 Nitrile 9 9 S212GF02N5FG91

1 13 5 200 140 150 140 100 100 — — 230 Viton 9 9 S212GF02V5FG9

1 13 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5FG9

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 55: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 55For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

Page 56: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page56For ordering information, visit mountaincontrols.com.

S212 – 1" NPT, Stainless Steel Body, Type 316,Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

ALL S3

S 2 1 2 G F 0 2 E 7 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

1 13 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7FG9

1 13 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7FG91

1 13 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7FG9

1 13 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7FG9

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 57: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 57For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

Materials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

6.4

* Not available for all variations

- High Performance- 1" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally Open

Page 58: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page58For ordering information, visit mountaincontrols.com.

S212 – High Performance, 1" NPT, Stainless Steel Body-Type 316, Normally Open

S 2 1 2 G F 0 2 N 1 F G 9Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

F: 1” NPT G9: 1”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

11/2 3.3 1 200 140 200 140 200 140 — — 230 Nitrile 8 9 S212GF02N1FG9

1/2 3.3 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1FG9

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 59: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 59For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 60: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page60For ordering information, visit mountaincontrols.com.

S211 – 1 1/4" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 G J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass G: 1 1/4” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

1 1/4 19 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5GJ2

1 1/4 19 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02N5GJ21 1/4

1 1/4 19 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02V5GJ2

1 1/4 19 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5GJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 61: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page61For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 62: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page62For ordering information, visit mountaincontrols.com.

S211 – 1 1/4" NPT, Stainless Steel Body, Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

S 2 1 1 G F 0 2 E 7 G J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS G: 1 1/4” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

1 1/4 19 10 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7GJ2

1 1/4 19 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7GJ21 1/4

1 1/4 19 10 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7GJ2

1 1/4 19 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7GJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 63: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page63For ordering information, visit mountaincontrols.com.

S21 Series

326ADimensions/Weight

- High Performance- 1 1/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2” Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 64: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page64For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 4 G J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: Brass2: Brass

G: 1 1/4” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1 1/41 1/2 22 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4GJ5

1 1/2 22 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2GJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/4" NPT, Brass Body,Normally Closed

Page 65: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page65For ordering information, visit mountaincontrols.com.

S21 Series

326ADimensions/Weight

- High Performance- 1 1/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 66: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page66For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 1 G J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

G: 1 1/4” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1 1/41 1/2 22 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1GJ5

1 1/2 22 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1GJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/4" NPT, Stainless Steel Body-Type 316, Normally Closed

Page 67: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page67For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 68: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page68For ordering information, visit mountaincontrols.com.

S212 – 1 1/4" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 G J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass G: 1 1/4” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

ALL S3

1 1/4 19 5 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5GJ2

1 1/4 19 5 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5GJ21 1/4

1 1/4 19 5 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5GJ2

1 1/4 19 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5GJ2

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 69: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page69For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 70: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 70For ordering information, visit mountaincontrols.com.

S212 – 1 1/4" NPT, Stainless Steel Body, Type 316,Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

ALL S3

S 2 1 2 G F 0 2 E 7 G J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS G: 1 1/4” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

1 1/4 19 5 200 150 150 150 85 85 — — 295 EPR 9 9 S212GF02E7GJ2

1 1/4 19 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7GJ21 1/4

1 1/4 19 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7GJ2

1 1/4 19 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7GJ2

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 71: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 71For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1 1/4" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 72: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 72For ordering information, visit mountaincontrols.com.

S 2 1 2 G F 0 2 N 4 G J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: ForgedBrass

2: Brass

G: 1 1/4” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

1 1/41 1/2 22 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4GJ5

1 1/2 22 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T2GJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/4" NPT, Brass Body,Normally Open

Page 73: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 73For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1 1/4" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 74: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page74For ordering information, visit mountaincontrols.com.

S212 – High Performance, 1 1/4" NPT, Stainless SteelBody-Type 316, Normally Open

S 2 1 2 G F 0 2 N 1 G J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

G: 1 1/4” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

1 1/41 1/2 22 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1GJ5

1 1/2 22 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1GJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 75: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 75For ordering information, visit mountaincontrols.com.

S21 Series

308Dimensions/Weight

- 1 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 76: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page76For ordering information, visit mountaincontrols.com.

S211 – 1 1/2" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 H J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass H: 1 1/2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

1 1/4 25 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5HJ2

1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02N5HJ21 1/2

1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02V5HJ2

1 1/4 25 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5HJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 77: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 77For ordering information, visit mountaincontrols.com.

S21 Series

308Dimensions/Weight

- 1 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 78: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page78For ordering information, visit mountaincontrols.com.

S211 – 1 1/2" NPT, Stainless Steel Body, Type 316,Normally Closed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

S 2 1 1 G F 0 2 E 7 H J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS H: 1 1/2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

1 1/4 25 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7HJ2

1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7HJ21 1/2

1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7HJ2

1 1/4 25 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7HJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 79: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 79For ordering information, visit mountaincontrols.com.

326A

S21 Series

Dimensions/Weight

- High Performance- 1 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2” Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 80: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page80For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 4 H J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: Brass2: Brass

H: 1 1/2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1 1/21 1/2 28 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4HJ5

1 1/2 28 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2HJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/2" NPT, Brass Body,Normally Closed

Page 81: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page81For ordering information, visit mountaincontrols.com.

S21 Series

326BDimensions/Weight

- High Performance- 1 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 82: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page82For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 1 H J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

H: 1 1/2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

1 1/21 1/2 28 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1HJ5

1 1/2 28 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1HJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/2" NPT, Stainless Steel Body-Type 316, Normally Closed

Page 83: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page83For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 84: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page84For ordering information, visit mountaincontrols.com.

S212 – 1 1/2" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 H J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass H: 1 1/2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

ALL S3

1 1/4 25 3 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5HJ2

1 1/4 25 3 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5HJ21 1/2

1 1/4 25 3 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5HJ2

1 1/4 25 3 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5HJ2

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 85: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page85For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 1 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 86: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page86For ordering information, visit mountaincontrols.com.

S212 – 1 1/2" NPT, Stainless Steel Body, Type 316,Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

ALL S3

S 2 1 2 G F 0 2 E 7 H J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS H: 1 1/2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

1 1/4 25 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7HJ2

1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7HJ21 1/2

1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7HJ2

1 1/4 25 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7HJ2

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 87: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page87For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1 1/2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 88: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page88For ordering information, visit mountaincontrols.com.

S 2 1 2 G F 0 2 N 4 H J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: ForgedBrass

2: Brass

H: 1 1/2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

1 1/21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4HJ5

1 1/2 28 10 — — — — — — 100* 100* 366 Teflon 8 9 S212GH02T2HJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 1 1/2" NPT, Brass Body,Normally Open

Page 89: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page89For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 1 1/2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 90: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 90For ordering information, visit mountaincontrols.com.

S212 – High Performance, 1 1/2" NPT, Stainless SteelBody-Type 316, Normally Open

S 2 1 2 G F 0 2 N 1 H J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

H: 1 1/2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

1 1/21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1HJ5

1 1/2 28 10 — — — — — — 100* 100* 366 Teflon 8 9 S212GH02T1HJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 91: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 91For ordering information, visit mountaincontrols.com.

S21 Series

318Dimensions/Weight

- 2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

13.5

* Not available for all variations

Page 92: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 92For ordering information, visit mountaincontrols.com.

S211 – 2" NPT, Brass Body, Normally Closed

S 2 1 1 G F 0 2 C 5 J J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass J: 2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

1 1/4 28 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5JJ2

1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02N5JJ22

1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02V5JJ2

1 1/4 28 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5JJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 93: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 93For ordering information, visit mountaincontrols.com.

S21 Series

318Dimensions/Weight

- 2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Closed

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

13.5

* Not available for all variations

Page 94: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page94For ordering information, visit mountaincontrols.com.

S211 – 2" NPT, Stainless Steel Body, Type 316,Normally Closed

S 2 1 1 G F 0 2 E 7 J J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS J: 2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

ALL S3

1 1/4 28 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7JJ2

1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7JJ22

1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7JJ2

1 1/4 28 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7JJ2

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 95: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 95For ordering information, visit mountaincontrols.com.

S21 Series

328Dimensions/Weight

- High Performance- 2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 96: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page96For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 4 J J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: Brass2: Brass

J: 2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

21 1/2 29 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4JJ5

1 1/2 29 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2JJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 2" NPT, Brass Body,Normally Closed

Page 97: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 97For ordering information, visit mountaincontrols.com.

S21 Series

328Dimensions/Weight

- High Performance- 2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 98: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page98For ordering information, visit mountaincontrols.com.

S 2 1 1 G F 0 2 N 1 J J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

J: 2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

1: NormallyClosed

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 13 14

Coil Family

Type Size

All S3

21 1/2 29 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1JJ5

1 1/2 29 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T1JJ5

IN °F

Normally Closed

Valve Selection List

P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 2" NPT, Stainless Steel Body-Type 316, Normally Closed

Page 99: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 99For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

13.5

* Not available for all variations

Page 100: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 100For ordering information, visit mountaincontrols.com.

S212 – 2" NPT, Brass Body, Normally Open

S 2 1 2 G F 0 2 C 5 J J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

C: EPRN: NitrileV: Viton

5: Brass J: 2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

ALL S3

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

1 1/4 28 5 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5JJ2

1 1/4 28 5 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5JJ22

1 1/4 28 5 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5JJ2

1 1/4 28 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5JJ2

Page 101: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 101For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- 2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted Diaphragm- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

13.5

* Not available for all variations

Page 102: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 102For ordering information, visit mountaincontrols.com.

S212 – 2" NPT, Stainless Steel Body, Type 316,Normally Open

S 2 1 2 G F 0 2 E 7 J J 2Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

E: EPRJ: NitrileL: Viton

7: 316 SS J: 2” NPT J2: 1 1/4”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 19

Coil Family

Type Size

ALL S3

1 1/4 28 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7JJ2

1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7JJ22

1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7JJ2

1 1/4 28 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7JJ2

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 103: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 103For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 2" NPT- Brass Body- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 104: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page104For ordering information, visit mountaincontrols.com.

S 2 1 2 G F 0 2 N 4 J J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

4: ForgedBrass

2: Brass

J: 2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4JJ5

1 1/2 28 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T2JJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Brass Body

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

S211 – High Performance, 2" NPT, Brass Body,Normally Open

Page 105: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 105For ordering information, visit mountaincontrols.com.

S21 Series

Dimensions/Weight

- High Performance- 2" NPT- Stainless Steel Body

Type 316- 2-Way Piloted

Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®

Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.

Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: ±15° From Vertical

Approvals* Agency: UL Listed, UL Recognized, CSA Approved

® Registered Trademark of DuPont Co.

Weight (lbs.)

10.5

* Not available for all variations

Page 106: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page106For ordering information, visit mountaincontrols.com.

S212 – High Performance, 2" NPT, Stainless Steel Body-Type 316, Normally Open

S 2 1 2 G F 0 2 N 1 J J 5Series Operating

ModeHousing* Coil Class* Voltage* Seal

MaterialBody

MaterialPipe

Connection Orifice Size

S21 G: Conduit F: Class FH: Class H

02: 120/60110/50

N: NitrileT: Teflon/

EPR

1: StainlessSteel

J: 2” NPT J5: 1 1/2”

Part Numbering

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: NormallyOpen

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 36 36

Holding 18 22

Coil Family

Type Size

All S3

21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1JJ5

1 1/2 28 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1JJ5

IN °F

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

Orif

ice

Siz

e

Pip

e S

ize

Min

imum

AC DC AC DC AC DC AC DC AC DC

Sea

l Mat

eria

l

Max

F

luid

Tem

p.

CvNPT

Air/Gas Water Light Oil Steam*

Operating Pressure Differential (psi)Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZShown

Stainless Steel BodyType 316

( )

* Class H Coil Recommended for Steam and Other High Temperature Applications

Page 107: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally

Page 107


Recommended