GD6AS / ISA6006” Gravity LED Square Adjustable
LED LIGHT ENGINE ■ 82/92 CRI, 2700K, 3000K, 3500K or 4000K
■ 2 Step MacAdam (2 SDCM) ■ Rated life of >50,000 hours L70 based on LED testing per LM-80-08 and projected values using IESNA TM21-11
DIMMING ■ Phase Dimming 5% ■ 0-10V Dimming 1% ■ Forward/reverse dimming 1% (120V only)
■ EldoLED 0-10V 0.1% or 1% ■ Lutron® LDE1 Hi-Lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology
■ Lutron® LTEA2W Hi-Lume 1% 2-Wire LED driver (120V forward phase only)
■ DMX512 RDM 0.1%
OPTICS ■ 14° Narrow Spot, 20° Spot, 30° Narrow Flood, 40° Flood, 50° Wide Flood and 60° Very Wide Flood
■ Optics and filter media are field interchangeable
ELECTRICAL SYSTEM ■ Dedicated voltage options of 120V, 277V or 347V. Must be specified in catalog code
■ 347V available with -D101 in L1 to L7 only, consult factory for lead times
■ Multiple dimming drivers available ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.
FRAME CONSTRUCTIONConstructed from 16 and 18 gauge heavy duty powder coated cold rolled steel frame with a large access junction box. ETL listed for through wiring. LED light engine and driver are accessible from above or below ceiling. 40° vertical and 362° horizontal adjustment with locking.
REFLECTORSpecification grade reflector with 1.5mm thickness. Reflector available in black, clear, haze or white finish. Consult factory for other colors. Architectural, discrete polished self flange standard. Optional painted white flange is available.
INSTALLATIONThe luminaire is type Non-IC. Insulation must be kept at a minimum of 3” away from fixture. Accommodates up to 1 1/4” ceiling thickness. Universal mounting brackets included. Compatible with C-channel, flat bar, wood joist bar hanger and EMT. Bar hangers must be ordered separately. C-channel is recommended for T-bar ceilings. Max. ambient temperature: 95°F (35°C).
EMERGENCY BACKUPRemote test switch included. External battery operates LED load of up to 7W at a minimum of 400 lumens for 90 minutes (EM7), or 20W at a minimum of 1200 lumens for 90 minutes (EM20).
ACCESSORIESLuminaire accepts (1) media filter and (1) hex cell louver.
LISTING / WARRANTY ■ ETL Listed to US and Canadian standards for damp locations
■ 5-Year Intense LED Limited Warranty
Ceiling Cut Out: 6 1/2” x 6 1/2”Maximum Ceiling Thickness: 1 1/4”
18 1/2”
18 11/16”
14 3/16”
7”
5 3/4” 7”
9 3/8”40°
Reflector Part Number: (Example: ISA600HZ-SF)
Reflector Reflector Finish Trim
ISA600 HZWCB11
(Haze)(White)(Clear)(Black)
-SF-SFW
(Self Flanged)(Self Flanged White)
Accessories
PFL2-111PFL4-111PFLMB-111I100I200I400
(Linear Spread)(Soft Focus Lens)(Black Hex Louver)(C-Channel Bar Hangers)(Flat Bar Hangers)(Wood Joist Bar Hangers)
Notes: 1. L1 & L2 only available with -D1012. Available in 120V only3. eldoLED dimming available with L3-L114. Lutron® dimming available with L3-L85. DMX512 RDM available with L4-L116. 14° Optic (NS) available on L1-L9 only7. 50° for L1-L9 only accepts (1) media filter8. 60° Optic (VF) available on L10-L11 only. Accepts only one filter media accessory.9. 347V available with -D101 in L1 to L7 only, consult factory for lead times.10. EM20 only available for L5 to L1111. Consult Factory For Lead Times
Housing Part Number: (Example: GD6ASL327-DIM-NS)
Housing Wattage CCT / CRI Dimming Voltage Optic Options
GD6AS L11
L21
L3L4L5L6
(10W)(12W)(14W)(18W)(23W)(30W)
L7L8L9L10L11
(36W)(43W)(49W)(50W)(60W)
27279303093535940409
(2700K/82CRI)(2700K/92 CRI)(3000K/82 CRI)(3000K/92 CRI)(3500K/82 CRI)(3500K/92 CRI)(4000K/82 CRI)(4000K/92 CRI)
-DIM2
-D101-ED10V13
-ED10V013
-LUT4
-LUT22,4
-DMXR5
(Phase Dimming 5%)(0-10V Dimming 1%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(Lutron® LDE1 EcoSystem 1%)(Lutron® LTEA2W 2-Wire 1%)(DMX512 RDM 0.1%)
blank27349
(120V)(277V)(347V)
-NS6
-SP-NF-FL-WF7
-VF8
(14° Narrow Spot)(20° Spot)(30° Narrow Flood)(40° Flood)(50° Wide Flood)(60° Very Wide Flood)
EM7
EM2010
(7W Emergency Backupw/ Remote Test SwitchIOTA part #ILB-CP07-A)(20W Emergency Backup w/ Remote Test Switch IOTA ILB-CP20-HE-A)
ELECTRICAL DATA: (Data Based On 3000K/82CRI Configuration)
LED Light Engine
Nominal Delivered Lumens *
System Wattage ** Efficacy
LED Light Engine
Nominal Delivered Lumens *
System Wattage ** Efficacy
L1L2L3L4L5L6
1000lm1500lm2000lm2500lm3000lm3500lm
10W12W14W18 W23W30W
100 lm/W125 lm/W143 lm/W139 lm/W130 lm/W117 lm/W
L7L8L9
L10L11
4000lm4500lm5000lm6000lm7000lm
36W43W49W50W60W
111 lm/W105 lm/W102 lm/W120 lm/W117 lm/W
* Delivered lumen output will vary depending on CCT, CRI, optic and reflector finish. | ** System Wattage include driver and LED Module consumption.
JOB NAME
CATALOG NUMBER
NOTES TYPE
GRAVITY ADJUSTABLE L/M-0728:21 P-6
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2021 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
GD6ASL3ISA600HZReport #: ILL20200129-2.001 (14) ILL20200129-10.001 (20) ILL20200130-6.001 (30) ILL20200130-12.001 (40) ILL20200131-6.001 (50)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.95) (x 0.79)3000K (x 1.00) (x 0.82)3500K (x 1.02) (x 0.85)4000K (x 1.03) (x 0.88)
3.1’
6.1’
9.2’
12.3’
Intensity
Degree0°5°15°25°35°45°
CBCP188161461418538106531
8.2fc
15fc
33fc
131fc
Beam Diameter
Foot-candlesat Nadir
48’
36’
24’
12’
Throw Distance
14° Narrow Spot
4.4’
8.8’
13’
18’
Intensity
Degree0°5°15°25°35°45°
CBCP11366853828298525133
4.9fc
8.8fc
20fc
79fc
Foot-candlesat Nadir
20° Spot
Intensity
Degree0°5°15°25°35°45°
CBCP57495471303312518427
2.5fc
4.4fc
10fc
40fc 6.7’
13’
20’
27’
Foot-candlesat Nadir
30° Narrow Flood
Intensity
Degree0°5°15°25°35°45°
CBCP448243153122137310436
2.0fc
3.5fc
7.8fc
31fc 8.6’
17’
26’
35’
Foot-candlesat Nadir
40° Flood
Intensity
Degree0°5°15°25°35°45°
CBCP2011197417001249640217
0.9fc
1.5fc
3.5fc
14fc 13’
27’
40’
53’
Foot-candlesat Nadir
50° Wide Flood
0° HORIZONTAL 40° HORIZONTAL 40° VERTICAL
D FC W L D C FC W L D C FC W L
GD6ASL330-1414° Narrow Spot
12’24’36’48’
130.6732.6714.528.17
3.076.149.2
12.27
3.156.319.4612.62
12’24’36’48’
10.0720.1430.2140.28
58.7414.686.533.67
5.4410.8816.3221.76
4.018.0112.0216.02
6’12’18’24’
7.1514.321.4528.6
138.8134.715.428.68
2.394.777.169.55
3.917.8311.7415.65
GD6ASL330-2020° Spot
12’24’36’48’
78.9319.738.774.93
4.398.7913.1817.58
4.398.7913.1817.58
12’24’36’48’
10.0720.1430.2140.28
35.488.873.942.22
7.6715.3423.0130.68
5.7411.4717.2122.94
6’12’18’24’
7.1514.321.4528.6
83.8520.969.325.24
3.426.8410.2513.67
5.5811.1716.7522.33
GD6ASL330-3030° Narrow Flood
12’24’36’48’
39.939.984.442.50
6.6913.3820.0726.76
6.7213.4520.1726.89
12’24’36’48’
10.0720.1430.2140.28
17.954.491.991.12
12.1324.2536.3848.51
8.7317.4726.2034.93
6’12’18’24’
7.1514.321.4528.6
42.4110.604.712.65
5.2010.4115.6120.82
9.1618.3127.4736.63
GD6ASL330-4040° Flood
12’24’36’48’
31.137.783.461.95
8.6117.2325.8434.45
8.6817.3526.0334.70
12’24’36’48’
10.0720.1430.2140.28
13.993.501.550.87
16.2832.5748.8565.13
11.2422.4933.7344.97
6’12’18’24’
7.1514.321.4528.6
33.078.273.672.07
6.7013.4020.1026.80
12.8925.7838.6851.57
GD6ASL330-5050° Wide Flood
12’24’36’48’
13.963.491.550.87
13.3426.6740.0153.35
13.3226.6339.9553.27
12’24’36’48’
10.0720.1430.2140.28
6.281.570.700.39
28.9757.9586.92115.90
17.4134.8252.2369.64
6’12’18’24’
7.1514.3021.4528.6
14.833.711.650.93
10.3720.7531.1241.50
28.6457.2885.91114.55
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
Watts: 14Lumens: 2180
LPW: 156 CCT: 3000K
Watts: 14Lumens: 2210
LPW: 158 CCT: 3000K
Watts: 14Lumens: 2166
LPW: 155 CCT: 3000K
Watts: 14Lumens: 2161
LPW: 154 CCT: 3000K
Watts: 14Lumens: 1975
LPW: 141 CCT: 3000K
JOB NAME
CATALOG NUMBER
NOTES TYPE
GRAVITY ADJUSTABLE L/M-0728:21 P-7
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2021 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
GD6ASL4ISA600HZReport #: ILL20200129-2.001 (14) ILL20200129-10.001 (20) ILL20200130-6.001 (30) ILL20200130-12.001 (40) ILL20200131-6.001 (50)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.95) (x 0.79)3000K (x 1.00) (x 0.82)3500K (x 1.02) (x 0.85)4000K (x 1.03) (x 0.88)
3.1’
6.1’
9.2’
12.3’
Intensity
Degree0°5°15°25°35°45°
CBCP188161461418538106531
8.2fc
15fc
33fc
131fc
Beam Diameter
Foot-candlesat Nadir
48’
36’
24’
12’
Throw Distance
14° Narrow Spot
4.4’
8.8’
13’
18’
Intensity
Degree0°5°15°25°35°45°
CBCP11366853828298525133
4.9fc
8.8fc
20fc
79fc
Foot-candlesat Nadir
20° Spot
Intensity
Degree0°5°15°25°35°45°
CBCP57495471303312518427
2.5fc
4.4fc
10fc
40fc 6.7’
13’
20’
27’
Foot-candlesat Nadir
30° Narrow Flood
Intensity
Degree0°5°15°25°35°45°
CBCP448243153122137310436
2.0fc
3.5fc
7.8fc
31fc 8.6’
17’
26’
35’
Foot-candlesat Nadir
40° Flood
Intensity
Degree0°5°15°25°35°45°
CBCP2011197417001249640217
0.9fc
1.5fc
3.5fc
14fc 13’
27’
40’
53’
Foot-candlesat Nadir
50° Wide Flood
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
0° HORIZONTAL 40° HORIZONTAL 40° VERTICAL
D FC W L D C FC W L D C FC W L
GD6ASL430-1414° Narrow Spot
12’24’36’48’
163.1240.7818.1210.20
3.076.149.2
12.27
3.156.319.4612.62
12’24’36’48’
10.0720.1430.2140.28
73.3318.338.154.58
5.4410.8816.3221.76
4.018.0112.0216.02
6’12’18’24’
7.1514.321.4528.6
173.2943.3219.2510.83
2.394.777.169.55
3.917.8311.7415.65
GD6ASL430-2020° Spot
12’24’36’48’
98.5424.6310.956.16
4.398.7913.1817.58
4.398.7913.1817.58
12’24’36’48’
10.0720.1430.2140.28
44.3011.074.922.77
7.6715.3423.0130.68
5.7411.4717.2122.94
6’12’18’24’
7.1514.321.4528.6
104.6826.1711.636.54
3.426.8410.2513.67
5.5811.1716.7522.33
GD6ASL430-3030° Narrow Flood
12’24’36’48’
49.8412.465.543.12
6.6913.3820.0726.76
6.7213.4520.1726.89
12’24’36’48’
10.0720.1430.2140.28
22.415.602.491.40
12.1324.2536.3848.51
8.7317.4726.2034.93
6’12’18’24’
7.1514.321.4528.6
52.9513.245.883.31
5.2010.4115.6120.82
9.1618.3127.4736.63
GD6ASL430-4040° Flood
12’24’36’48’
38.869.714.322.43
8.6117.2325.8434.45
8.6817.3526.0334.70
12’24’36’48’
10.0720.1430.2140.28
17.474.371.941.09
16.2832.5748.8565.13
11.2422.4933.7344.97
6’12’18’24’
7.1514.321.4528.6
41.2810.324.592.58
6.7013.4020.1026.80
12.8925.7838.6851.57
GD6ASL430-5050° Wide Flood
12’24’36’48’
17.434.361.941.09
13.3426.6740.0153.35
13.3226.6339.9553.27
12’24’36’48’
10.0720.1430.2140.28
7.841.960.870.49
28.9757.9586.92115.90
17.4134.8252.2369.64
6’12’18’24’
7.1514.3021.4528.6
18.524.632.061.16
10.3720.7531.1241.50
28.6457.2885.91114.55
Watts: 18Lumens: 2721
LPW: 151 CCT: 3000K
Watts: 18Lumens: 2759
LPW: 153 CCT: 3000K
Watts: 18Lumens: 2704
LPW: 150 CCT: 3000K
Watts: 18Lumens: 2698
LPW: 150 CCT: 3000K
Watts: 18Lumens: 2466
LPW: 137 CCT: 3000K
JOB NAME
CATALOG NUMBER
NOTES TYPE
GRAVITY ADJUSTABLE L/M-0728:21 P-8
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2021 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
GD6ASL5ISA600HZReport #: ILL20200129-2.001 (14) ILL20200129-10.001 (20) ILL20200130-6.001 (30) ILL20200130-12.001 (40) ILL20200131-6.001 (50)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.95) (x 0.79)3000K (x 1.00) (x 0.82)3500K (x 1.02) (x 0.85)4000K (x 1.03) (x 0.88)
3.1’
6.1’
9.2’
12.3’
Intensity
Degree0°5°15°25°35°45°
CBCP188161461418538106531
8.2fc
15fc
33fc
131fc
Beam Diameter
Foot-candlesat Nadir
48’
36’
24’
12’
Throw Distance
14° Narrow Spot
4.4’
8.8’
13’
18’
Intensity
Degree0°5°15°25°35°45°
CBCP11366853828298525133
4.9fc
8.8fc
20fc
79fc
Foot-candlesat Nadir
20° Spot
Intensity
Degree0°5°15°25°35°45°
CBCP57495471303312518427
2.5fc
4.4fc
10fc
40fc 6.7’
13’
20’
27’
Foot-candlesat Nadir
30° Narrow Flood
Intensity
Degree0°5°15°25°35°45°
CBCP448243153122137310436
2.0fc
3.5fc
7.8fc
31fc 8.6’
17’
26’
35’
Foot-candlesat Nadir
40° Flood
Intensity
Degree0°5°15°25°35°45°
CBCP2011197417001249640217
0.9fc
1.5fc
3.5fc
14fc 13’
27’
40’
53’
Foot-candlesat Nadir
50° Wide Flood
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
0° HORIZONTAL 40° HORIZONTAL 40° VERTICAL
D FC W L D C FC W L D C FC W L
GD6ASL530-1414° Narrow Spot
12’24’36’48’
195.8648.9621.7612.24
3.076.149.2
12.27
3.156.319.4612.62
12’24’36’48’
10.0720.1430.2140.28
88.0422.019.785.50
5.4410.8816.3221.76
4.018.0112.0216.02
6’12’18’24’
7.1514.321.4528.6
208.0752.0223.1213.00
2.394.777.169.55
3.917.8311.7415.65
GD6ASL530-2020° Spot
12’24’36’48’
118.3129.5813.157.39
4.398.7913.1817.58
4.398.7913.1817.58
12’24’36’48’
10.0720.1430.2140.28
53.1813.305.913.32
7.6715.3423.0130.68
5.7411.4717.2122.94
6’12’18’24’
7.1514.321.4528.6
125.6931.4213.977.86
3.426.8410.2513.67
5.5811.1716.7522.33
GD6ASL530-3030° Narrow Flood
12’24’36’48’
59.8514.966.653.74
6.6913.3820.0726.76
6.7213.4520.1726.89
12’24’36’48’
10.0720.1430.2140.28
26.906.732.991.68
12.1324.2536.3848.51
8.7317.4726.2034.93
6’12’18’24’
7.1514.321.4528.6
63.5815.897.063.97
5.2010.4115.6120.82
9.1618.3127.4736.63
GD6ASL530-4040° Flood
12’24’36’48’
46.6611.665.182.92
8.6117.2325.8434.45
8.6817.3526.0334.70
12’24’36’48’
10.0720.1430.2140.28
20.975.242.331.31
16.2832.5748.8565.13
11.2422.4933.7344.97
6’12’18’24’
7.1514.321.4528.6
49.5712.395.513.10
6.7013.4020.1026.80
12.8925.7838.6851.57
GD6ASL530-5050° Wide Flood
12’24’36’48’
20.935.232.331.31
13.3426.6740.0153.35
13.3226.6339.9553.27
12’24’36’48’
10.0720.1430.2140.28
9.412.351.050.59
28.9757.9586.92115.90
17.4134.8252.2369.64
6’12’18’24’
7.1514.3021.4528.6
22.245.562.471.39
10.3720.7531.1241.50
28.6457.2885.91114.55
Watts: 23Lumens: 3268
LPW: 142 CCT: 3000K
Watts: 23Lumens: 3312
LPW: 144 CCT: 3000K
Watts: 23Lumens: 3247
LPW: 141 CCT: 3000K
Watts: 23Lumens: 3239
LPW: 141 CCT: 3000K
Watts: 23Lumens: 2961
LPW: 129 CCT: 3000K
JOB NAME
CATALOG NUMBER
NOTES TYPE
GRAVITY ADJUSTABLE L/M-0728:21 P-9
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2021 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
40°
0° HORIZONTAL 40° HORIZONTAL 40° VERTICAL
D FC W L D C FC W L D C FC W L
GD6ASL630-1414° Narrow Spot
12’24’36’48’
228.5957.1525.4014.29
3.076.149.2
12.27
3.156.319.4612.62
12’24’36’48’
10.0720.1430.2140.28
102.7625.6911.426.42
5.4410.8816.3221.76
4.018.0112.0216.02
6’12’18’24’
7.1514.321.4528.6
242.8460.7126.9815.18
2.394.777.169.55
3.917.8311.7415.65
GD6ASL630-2020° Spot
12’24’36’48’
138.0934.5215.348.63
4.398.7913.1817.58
4.398.7913.1817.58
12’24’36’48’
10.0720.1430.2140.28
62.0715.526.903.88
7.6715.3423.0130.68
5.7411.4717.2122.94
6’12’18’24’
7.1514.321.4528.6
146.6936.6716.309.17
3.426.8410.2513.67
5.5811.1716.7522.33
GD6ASL630-3030° Narrow Flood
12’24’36’48’
69.8517.467.764.37
6.6913.3820.0726.76
6.7213.4520.1726.89
12’24’36’48’
10.0720.1430.2140.28
31.407.853.491.96
12.1324.2536.3848.51
8.7317.4726.2034.93
6’12’18’24’
7.1514.321.4528.6
74.2018.558.244.64
5.2010.4115.6120.82
9.1618.3127.4736.63
GD6ASL630-4040° Flood
12’24’36’48’
54.4613.616.053.40
8.6117.2325.8434.45
8.6817.3526.0334.70
12’24’36’48’
10.0720.1430.2140.28
24.486.122.721.53
16.2832.5748.8565.13
11.2422.4933.7344.97
6’12’18’24’
7.1514.321.4528.6
57.8514.466.433.62
6.7013.4020.1026.80
12.8925.7838.6851.57
GD6ASL630-5050° Wide Flood
12’24’36’48’
24.436.112.711.53
13.3426.6740.0153.35
13.3226.6339.9553.27
12’24’36’48’
10.0720.1430.2140.28
10.982.751.220.69
28.9757.9586.92115.90
17.4134.8252.2369.64
6’12’18’24’
7.1514.3021.4528.6
25.956.492.881.62
10.3720.7531.1241.50
28.6457.2885.91114.55
GD6ASL6ISA600HZReport #: ILL20200129-2.004 (14) ILL20200129-10.004 (20) ILL20200130-6.004 (30) ILL20200130-12.004 (40) ILL20200131-6.004 (50)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.95) (x 0.79)3000K (x 1.00) (x 0.82)3500K (x 1.02) (x 0.85)4000K (x 1.03) (x 0.88)
3.1’
6.1’
9.2’
12.3’
Intensity
Degree0°5°15°25°35°45°
CBCP32918255673242141711454
14fc
25fc
57fc
229fc
Beam Diameter
Foot-candlesat Nadir
48’
36’
24’
12’
Throw Distance
14° Narrow Spot
4.4’
8.8’
13’
18’
Intensity
Degree0°5°15°25°35°45°
CBCP1988414937495014908958
8.6fc
15fc
35fc
138fc
Foot-candlesat Nadir
20° Spot
Intensity
Degree0°5°15°25°35°45°
CBCP1005895725306218914748
4.4fc
7.8fc
18fc
70fc 6.7’
13’
20’
27’
Foot-candlesat Nadir
30° Narrow Flood
Intensity
Degree0°5°15°25°35°45°
CBCP784275505461240218263
3.4fc
6.1fc
14fc
55fc 8.6’
17’
26’
35’
Foot-candlesat Nadir
40° Flood
Intensity
Degree0°5°15°25°35°45°
CBCP35183453297421851120380
1.5fc
2.7fc
6.1fc
24fc 13’
27’
40’
53’
Foot-candlesat Nadir
50° Wide Flood
Watts: 30Lumens: 3814
LPW: 127 CCT: 3000K
Watts: 30Lumens: 3866
LPW: 129 CCT: 3000K
Watts: 30Lumens: 3789
LPW: 126 CCT: 3000K
Watts: 30Lumens: 3780
LPW: 126 CCT: 3000K
Watts: 30Lumens: 3456
LPW: 115 CCT: 3000K
JOB NAME
CATALOG NUMBER
NOTES TYPE
GRAVITY ADJUSTABLE L/M-0728:21 P-10
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2021 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.