Company ProfileGekonis was formed in September 2014 by experienced IT professional with 20+ working experience in the city of Brno the second largest city of Czech Republic.
Projects:- hosting for internal and external geoportal for E.O.N from September 2014 to September 2015- implementation Document management system based on SharePoint for Wustenrot Slovakia - just running- Document management implementation for Česká Spořitelna (bank) - about 60 mil CZK- intranet portal for Český telecom/O2- ERP implementation in Mattoni (Karolvarské minerální vody, Karlovarske mineral water)
WWW. .CZ
Services
DatacentreHosting ConsultingHardware / Software Solutions
WWW. .CZ
Serverhousing Webhosting cPanel hosting Software as a Service Infrastructure as a Service DR locality Infrastructure monitoring and management
Data Centre
WWW. .CZ
Consulting
Project Management Businness Analysis Data Center Design IT infrastructure Design Virtualization (VMware, Hyper-V, KVM) Cloud Services Backup
WWW. .CZ
HW / SW solutions
Document Management System Fujitsu Servers and Data Storage Fujitsu Document Scanners VMware SUSE Linux Microsoft
WWW. .CZ
Data Centre Datacube
WWW. .CZ
TIER level: TIER III+IT space : 2700 m2
Office spaces for rent 670 m2
Storage space 330 m2
Power density 2,2 kW/m2
Racks power input 1-25kWCurrent power capacity 3,6MVAFull power capacity 20MVADiesel generators – Actual 2 x 2,2MVADiesel generators – Full 13 x 2,2MVAUPS capacity for at least 10 minUPS redundancy 2(N+1)Raised floor 1m
IT rooms height 6,2mFloor loading 1500 to 5000kg/ m2
On site Fuel for Diesel generators for 72 hours
3m high Security Fence + crash barriers
Automatic Fire Surpression system based on Nitrogen
VESDA system in all technology and IT rooms
Redundancy N+1 to 2(N+1)
Technical Highlights
WWW. .CZ
Gallery
WWW. .CZ
WWW. .CZ
WWW. .CZ
Size and SpaceThe Datacube complex is composed of two newly constructed buildings on a property land site of approx. 9000 square meters.
The first building of approx. 3500 square meters has been contracted to a multinational mobile operator for the housing of its own equipment
The second building of approx 6500 square meters has been constructed as a Tier III+ collocation facility. The space is divided as follows:
2700 square meters – net server space available for lease 670 square meters – office space available for lease 330 square meters – storage space available for lease2800 square meters – operations offices, technical space, entrance, security room, loading, etc
WWW. .CZ
LocationThe Datacube site is located in an industrial zone at the edge of Bratislava, 10 minutes from the city center and 40 minutes from the Vienna airport.
This site was selected in accordance with Tier III conditions and a view towards the constant increase in energy consumption of data centers
The site is less than 1 km from two independent 110kV electrical sub- stations each with spare capacity of more than 20 MW.
The site is 900m from Slovakia’s main telecommunications hub and less than 600 m from the major international and local fiber routes.
The site is far from residential units, railway lines, flight paths and other complications that can impact/restrict data center performance.
The site is officially outside of any 100+ year flood areas.
WWW. .CZ
Building ConstructionExtremely robust steel reinforced concrete structure
Steel reinforced concrete walls 18 cm thick
Double roof with unique perforation detection
External and internal walls and doors with certified fire resistance from 90 to 120 minutes.
Secure loading dock and freight elevator for on-site equipment delivery.
Sophisticated grounding system and advanced lightning protection.
Floor loading:Ground floor 5000 kg/m2Other floors 1500 kg/m2Roof 1500 kg/m2
WWW. .CZ
PowerDirectly to a 110kV/22kV sub station via our own dedicated 22kV cable with capacity of 10MVA. This capacity can be increased in the future according to actual energy requirements up to 20 MVA.
Another 110kV/22kV sub station with significant spare capacity is located less than 1 km away as a potential third power connection
2 separate UPS systems with batteries (A+B), each in a redundant N+1 configuration.
On-site generators (2.2 kVA) as a source of back-up energy in a redundant N+1 configuration with fuel supply for 72 hours of continual service.
Each rack can be served by 2 independent power supplies (16A, 32A, 63A), single-phase or triple-phase.
WWW. .CZ
CoolingHighly efficient and secure dry cooler system with maximized use of free cooling when ambient outside temperatures are low.
All elements of the cooling system are in a redundant N+1 configuration.
One meter raised floor provides for more efficient and effective cooling of customer equipment.
Exceptionally high (5.2 meter) ceilings in IT space allows hot air to rise keeping customer equipment cool.
Low Density zoneCRAC units with distribution of chilled air through the raised floor. System of cold and hot aisles
High Density zoneIn-row cooling units in closed aisles up to 10kW/rackEnclosed racks with intensive water cooled systems up to 25kW/rack
WWW. .CZ
Fiber ConnectionsBratislava is the crossing point for multiple operators’ Prague-Vienna-Budapest- Kiev fiber routes.
Datacube is connected via fiber to the main existing telecom hub in Slovakia
Discussions are under way so that every major international carrier active in the region will be connected to the Data Center through two independent fiber routes.
The high numbers of carriers that will be present ensures the ability to obtain the best possible terms and conditions of telecom services.
WWW. .CZ
Security / Fire Suppression
High level of physical security of the facility with multiple layer electronic control of entrance and movement of people and vehicles. IT Rooms and technology spaces have been built according to the European Union Security Standard ENV 1627 class 3Manned security service 24x7x365Video monitoring and recording of all parts of the Data Center facilities (interior and exterior).High security fence with a sophisticated electronic perimeter detection system.
Fire Control and SuppressionVESDA (Very Early Smoke Detection Alarm) system. Internal space is divided into multiple fire sectors Inert gas (nitrogen) fire suppression system
WWW. .CZ
Ahsan AslamTel: +420 737 888 488
[email protected]ěch Krejčíř
Tel: +420 602 523 [email protected]
http://www.gekonis.cz