+ All Categories
Home > Documents > Gemini 7562

Gemini 7562

Date post: 31-Dec-2015
Category:
Upload: denis-raudsepp
View: 421 times
Download: 35 times
Share this document with a friend
Description:
alarm manual gemini
Popular Tags:
9
7060 AC 2529 - REV. 00 / 06 / 01 No forest has been destroyed to produce this 100% recycled paper. by GEMINI TRADING S.r.l. Via Luigi Galvani 12 21020 Bodio Lomnago (VA) Italia Tel. +39 0332 943211 - Fax +39 0332 948080 E-mail : [email protected] 7208 0682 INSTALLATION MANUAL
Transcript
Page 1: Gemini 7562

7060

AC 2529 - REV. 00 / 06 / 01

No forest has been destroyed to

produce this 100% recycled paper.

by GEMINI TRADING S.r.l. Via Luigi Galvani 12 21020 Bodio Lomnago (VA) Italia

Tel. +39 0332 943211 - Fax +39 0332 948080

E-mail : [email protected]

7208 0682

INSTALLATION MANUAL

Page 2: Gemini 7562

DESCRIPTION

GEMINI 7060 The system 7060 is an alarm unit that can be installed on vehicles with 12 volts battery (negative earth).

FUNCTIONS - Remote controlled alarm unit with dynamic code.

- Blinker, universal central door locking control, electric windows and sunroof closure for selected vehicles equipped with “Pack Comfort” system.

- Perimetric protection and outlet for additional modules.

- Controls for self-powered siren, additional siren (continuous or alternate sound) and horn.

- LED’s Memory.

- Acoustic activation/de-activation (through siren or horn).

- Remote controlled panic function and / or boot opening.

- Electric engine immobilisation.

- Alarm unit functions programmable through the transmitter.

The unit is equipped with two 2-channel transmitters (art. 7208E), frequency 433.92 Mhz.

USEFUL SUGGESTIONS FOR THE INSTALLATION

- Connect the positive and negative feeding wire of the alarm system to the battery.

- Connect always the alarm Green-Brown wire to the door pin switch.

- On catalysed vehicles the engine immobilisation must be carried out on the fuel pump and the starter motor.

- Avoid routing connection wires next to interference sources.

- The ultrasonic heads must be positioned at the top of each windscreen pillar and must be pointing at each opposite diagonal corner away from the facia outlets.

WIRING CONNECTIONS

Disconnect the negative terminal of the battery and only re-connect after the installation is complete. FUNCTION WIRE COLOR

Earth ðð BROWN Battery positive terminal ðð RED Engine immobilisation (max. 10 A) ðð 2 X GREY Ignition live ðð YELLOW Direction indicator lights ðð 2 x ORANGE Door pin switch ðð GREEN-BROWN Boot/bonnet pin switches ðð GREEN Positive alarm armed ðð PINK External sensors inlet ðð GREEN-BLACK Self-powered siren control ðð BLUE Common +/- siren or klaxon ðð BLACK Additional siren or horn control ðð YELLOW-BLACK Negative control boot opening ðð GREY-BLACK Comfort ðð WHITE-BLACK Central door locking ðð

YELLOW-BLUE, RED-BLUE, YELLOW-GREY, RED-GREY, YELLOW-BROWN, RED-BROWN

Note: The wiring harness has 2 connectors: connect the 2-pin connector to the LED and the 4-pin connector to an additional module (shock, ultrasonic or super-high frequency module).

"DIP SWITCHES PROGRAMMING TABLE" 1 OFF Comfort POSITIVE 2 ON Comfort NEGATIVE 2 OFF Automatic arming OFF 2 ON Automatic arming ON 3 OFF Self-learning of a new code OFF (normal use) 3 ON Self-learning of a new code ON 4 OFF Closure short * period 4 ON Closure 6 seconds

* THE SHORT TIME IS SET FROM THE PROGRAMMING WITH THE TWO-CHANNELS TRANSMITTER BETWEEN 0,5 SECONDS AND 1 SECOND. ATTENTION: SET THE DIP SWITCHES BEVOR FEEDING THE 7060 UNIT.

TABLE OF PROGRAMMABLE FUNCTIONS THROUGH THE TWO-CHANNELS TRANSMITTER.

ACTIONS

ALARM CONDITION VISIBLE ACTIONS

LED FLASHING AND SELECTED FUNCTIONS

ALTERNATIVE ACTIONS

POWER OFF Alarm OFF - - - Turn the ignition

key to ON

Alarm OFF

-

-

-

FEED THE UNIT 7060

Alarm ON

-

-

-

Press on the transmitter 1 button within 10 seconds

Access to the Set-up 1 function: Supplementary siren

One blinker flashing

One flashing = continuous

Two flashing = intermittent

Press on the transmitter 1 button

Access to the Set-up 2 function: acoustic signalling with

supplementary siren 725

Two blinker flashing

One flashing = de-activated

Two flashing = activated

Press on the

transmitter 1 button

Access to the Set-up 3 function: Panic and boot opening through

the transmitter

Three blinker flashing

One flashing = Panic and additional siren

Two flashing = Boot opening

Press on the

transmitter 1 button

Access to the Set-up 4 function: boot opening while alarm armed

(Panic excluded)

Four blinker flashing

One flashing = While alarm disarmed

Two flashing = For both functions

Press on the

transmitter 1 button

Access to the Set-up 5 function: vehicle check while arming the

system

Five blinker flashing

One flashing = de-activated

Two flashing = activated

Press on the transmitter 1 button

Access to the Set-up 6 function: closure control period

Six blinker flashing

One flashing = 0,5 seconds

Two flashing = 1 seconds

Press on the transmitter 1 button

Access to the Set-up 7 function: Automatic arming with door

closure

Seven blinker flashing

One flashing = activated

Two flashing = de-activated

Press on the transmitter 1 button

Access to the Set-up 8 function: Comfort

Eight blinker flashing

One flashing = while closing

Two flashing = after the closure

Press on the transmitter

button N. 2 to change the

selected option.

De-activate the +15 to memorise

the selected options and to exit from User

set-up.

Turn the ignition key to OFF

Set-up exit, normal working of the alarm - - -

Page 3: Gemini 7562

Recapitulatory table of the programmable functions through the two -channels transmitter. Function Manufacturer function Programmable function

1 Additional siren outlet Continuous sound Alternate sound 2 Acoustic signalling De-activated Activated 3 Boot opening with alarm disarmed De-activated Activated 4 Boot opening with alarm armed

With alarm disarmed if the 3 functions has been activated

Both functions (Panic excluded)

5 Vehicle’s check De-activated Activated 6 Central door locking short period 0,5 seconds 1 second 7 Automatic arming Activated De-activated 8 Comfort While closing the doors After the blinker flashing

WORKING DESCRIPTION

- ALARM ARMING: press on the transmitter’s button N. 1. One pulse of the direction indicator lights signals the arming.

- EXCLUSION OF THE VOLUMETRIC SENSOR, EXTERNAL SENSORS AND COMFORT CONTROL AFTER THE ALARM ARMING: while alarm armed (even if the boot opening function with alarm armed is activated), during the inhibit time (Led lightning fix) press on the transmitter 2 button. The exclusion is signalled by one pulse of the direction indicator lights, the comfort function and the sensors are excluded. This function de-activates at the first arming of the alarm.

- ALARM DISARMING: press on the transmitter’s button N. 1. The disarming is signalled through 3 pulses of the direction indicator lights or 5 pulses if an alarm condition

has occurred.

SPECIAL FUNCTIONS SELF-LEARNING OF THE CODE OF A NEW TRANS MITTER. The self-learning of a new transmitter can be obtained with two different ways: 1. While alarm disarmed set the dip switch N.3 to ON and turn the ignition key to ON. The Led and the direction

indicator lights activate. Turning the ignition key to OFF the Led and the direction indicator lights switch off. Press on the new transmitter button N. 1 within 8 seconds. For each new code it is necessary to turn the ignition key to ON for one second and then to OFF. At the end of the self-learning operation set the dip switch N.3 to OFF.

2. While alarm disarmed, open the driver’s door, turn the ignition key to ON and press on the coded transmitter button N. 2. The Led and the direction indicator lights activate. Turning the ignition key to OFF the Led and the direction indicator lights switch off. Press on the new transmitter’ s button N. 2 within 10 seconds. For each new code it is necessary to turn the ignition key to ON for one second and then to OFF. At the end of the self-learning operation, after 10 seconds the system works normally. NOTE: the system is supplied with a maximum number of 3 transmitters.

AUTOMATIC ARMING To obtain this function set the dip switch N. 2 to ON. 60 seconds after the disarming of the alarm, if the doors and the boot are not opened and the ignition key is not turned to ON, the system will arm with or without closing the vehicles doors (according to setting of the set-up 7 function). REMOTE CONTROLLED BOOT OPENING. The alarm unit 7060 allows opening the vehicle boot if the control is electric to negative. To obtain this function select the set-up 3 function and press on the transmitter button N. 2 with the alarm disarmed. If the boot opening is carried out pressing on the transmitter 2 button with the alarm armed (after selecting the set-up 4 function), the panic function will de-activate and all the inlets inhibit for 60 seconds. If the boot is not closed within this delay time the alarm will trigger. The opening of the boot through the transmitter is signalled by one pulse of the direction indicator lights.

PANIC FUNCTION To obtain this function with the alarm armed after the neutral time, press on the transmitter button N. 2 (if the 4 function- boot opening with alarm armed is de-activated). The siren, the klaxon and the direction indicator lights activate. To de-activate this function within the 10 seconds of the alarm cycle, press on the transmitter button N. 2. LEDS MEMORY. While disarming the alarm, turn the ignition key to ON to check if an attempted break-in has occurred. Following the Led flashing it is possible to know the alarm triggering’s cause. The signalisation is repeated for 5 times.

Signalling LED Alarm triggering Alarm cycle ¬¬l¬¬ Door and boot/bonnet pin switches. 10 ¬¬¬l¬¬¬ Ignition live Unlimited ¬¬¬¬l¬¬¬¬ External sensors 10

l LED OFF (2 seconds) ¬ LED ON (1 second) Each alarm cycle is 30 seconds The inhibit time is 30 seconds for all alarm triggering’s cause.

TRANSMITTERS BATTERY DISCHARGING

The discharging of the battery is signalled through the LED of the transmitter. If the LED flashes while pressing one of the transmitter’s buttons it is necessary to replace the batteries.

BATTERIES: CR1616

Note: put the batteries in the appropriate container.

TECHNICAL DATA

Power supply 10.5-14.5 V dc. Working temperature -40° C + 85°C Max. Current drawn alarm OFF 15 mA (with self-powered siren connected) Transmitters frequency 433.92 MHz Direction indicator lights relay contact capability 8A dc Engine immobilisation relay contact capability 8A dc Outlet horn relay contact capability 8A dc Central door locking relay contact capability 8A dc

GEMINI 7147

DESCRIPTION. GEMINI 7147 is 2 wires, high power electronic siren designed to be installed quickly and simply in the engine compartment.

WIRING CONNECTIONS (for the installer) Disconnect the negative terminal of the battery and only re-connect after the installation is complete.

WIRE COLOUR FUNCTION RED é Battery positive terminal (12V) BLACK é To the alarm YELLOW -BLACK wire.

NOTE: connect the BLACK wire of the unit to earth. INSTALLATION. Install the siren in the engine compartment using the bracket and the screws supplied with the kit. Install the siren away from areas of intense heat and turn to low the siren ear trumpet to avoid water infiltration. Protect the wires from water and humidity and to avoid any damaging do not steam clean directly to the siren.

Page 4: Gemini 7562

GEMINI 7025 DESCRIPTION. Gemini 7025 is a self-powered, high power, electronic siren studied to install in the vehicle’s engine compartment. To install the siren in the engine compartment use the bracket and the screws supplied with the kit and follow the fitting instructions. Install the siren on the vehicles bodywork away from areas of intense heat.

WIRING CONNECTIONS (for the installer) Disconnect the negative terminal of the battery and only re-connect after the installation is complete.

WIRE COLOUR FUNCTION BLACK marked RB ê Battery positive terminal BLACK marked MB ê Battery negative terminal BLACK marked S ê To the alarm PINK wire BLACK marked R ê To the alarm RED wire BLACK marked L ê To the alarm BLUE wire

NOTE: connect the BLACK wire of the unit to earth. Connect one end of the BLACK initialled V wire to the bonnet pin switch and the other end to the alarm GREEN wire.

NOTE: To disarm the alarm unit and the engine immobilisation, turn the siren key to off. The internal battery recharges with alarm disarmed.

TECHNICAL DATA

Power supply 12V Current absorption alarm ON 3mA Current absorption alarm OFF 7Ma (recharging battery). Audible tone > 118dB

Note: To avoid any damaging do not steam clean directly to the siren.

GEMINI 725

DESCRIPTION. Gemini 725 is a self-powered, high power, electronic siren studied to install in the vehicle’s engine compartment. To install the siren in the engine compartment use the bracket and the screws supplied with the kit and follow the fitting instructions. Install the siren on the vehicles bodywork away from areas of intense heat.

WIRING CONNECTIONS (for the installer) Disconnect the negative terminal of the battery and only re-connect after the installation is complete.

WIRE COLOUR FUNCTION RED ê Battery positive terminal BLACK ê Battery negative terminal

BLUE ê To the alarm unit YELLOW-BLACK wire NOTE: connect the BLACK wire of the unit to earth.

INSTALLATION. Install the siren in the engine compartment away from areas of intense heat using the bracket and the screws supplied with the kit.

TECHNICAL DATA Power supply 12V Current absorption 7mA (recharging battery) Audible tone > 118dB

Note: to avoid any damaging do not steam clean directly to the siren.

This device is guaranteed against any manufacturing or working fault for 12 months from purchase date. The manufacturer declines every responsibility for any defect or failure to the device and to the electric plant of the vehicle due to an incorrect installation or to the alteration of the technical data stated in this manual.

Page 5: Gemini 7562

YELLOW-GREY

Ignition Key

Common (+/-) for siren or clacsonNOTE: negative control for siren

Direction indicators lights

File : 7060centrale-UK CDR

YELLOW-BLUE

YELLOW-BROWNRED-GREY

RED-BROWN

RED-BLUE

Fitting diagramref.7060

Control for supplementary siren or clacson

YELLOW-BLACK

BLUE

Self-Powered Siren

GREEN-BROWN

Door pin switches

Refer to central door locking diagrams

Engine immobilisation

GREEN

Boot/Bonnet pin switch

External Sensor inlet

Push-botton 2Push-botton 1

GREY-BLACK(Negative control)

BLACK

Trunk release

+30

BROWN

EARTH

ORANGE

ORANGE

RED15A +

Battery12 VOLT

WHITE-BLACK

Comfort

RedBlack

7060

GREY

GREY

8AMAX !

5A

5A

1

1

2

2

3

3

4

4

ON

ON

Pin

kB

row

nG

ree

n-B

lac

k

+ -

Ultrasonic Module7059

5123

Optional

70607147

RED 5A

BLACKYELLOW-BLACK

BLACK

CLAMP

+_

BATTERY12VOLT

10A

RED

RED

RED +30

OK

NO!

Supplementary siren Gemini 7147 and Gemini 7060 interface

NEGATIVE

SIREN POSITIONING

Emergency Push-botton

Page 6: Gemini 7562

EX : ALFA,FIAT,FORD,LANCIA,OPEL,PEUGEOT,RENAULT,SAAB,SEAT,VW POLO(95-99)

YELLOW-BLUE

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

+30

Diagram 2

COMPRESSOROriginalMotor

EX : AUDI 80,MERCEDES 190

YELLOW-BLUE

+30

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

Diagram 3

EX : RENAULT TWINGO (<2000)

M M

Open

Close

YELLOW-BLUE

+30

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

Diagram 4

Ref.2305TYELLOW-BLUE

+30

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

BLUE

GREEN

Diagram 5

EX : HONDA CIVIC 5p(96) PRELUDE(96),HYUNDAI LANTRA(96),ACCENT(96),GALLOPER(98)

7060

7060

7060

70601

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

ON

ON

ON

ON

4 OFF

4 OFF

4 OFF

4 ON

Open,Apre,Ouvre,Auf,Apertura,Abre

Common,Comune,Comun,Je nuch Z.V.

Close,Chiude,Ferme,Zu,Cierre,Fecha

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Vehicles originaldoor lock switch

Page 7: Gemini 7562

Close OpenCommon

BROWNWHITEBLACK

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

YELLOW-BLUE

RED-BLUE

BLUE

GREEN

Diagram 6

+30

EX : DAEWOO NEXIA,OPEL FRONTERA (<99). AUDI 100,MERCEDES WITH PACK-COMFORT SISTEM(<96).

YELLOW-BLUE

+30

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

Diagram 8

COMPRESSOROriginalMotor

COMFORT,CONFORT,KOMFORTWHITE-BLACK

EX : BMW 3(<98),5(<96),7-8(96),Z3(97>)

YELLOW-BLUE

RED-BLUE

YELLOW-GREY

RED-GREY

YELLOW-BROWN

RED-BROWN

+30

Diagram 7

+ COMFORT, CONFORT, KOMFORT

WHITE-BLACK

YELLOW-BLUE

RED-BLUE

YELLOW-GREY

RED-GREY

WHITE-BLACK

YELLOW-BROWN

RED-BROWN

EX : AUDI A4, A6(<96),OPEL VECTRA(<96),OMEGA, SEAT TOLEDO (<96)

Diagram 9

COMFORT,CONFORT,KOMFORT

Negative Comfort

Negative Comfort

Positive Comfort

Positive Comfort

BLUE (Mercedes)

7060

70607060

7060

+30

1

1

1

1 1

2

2

2

2 2

3

3

3

3 3

4

4

4

4 4

ON

ON

ON

ON ON

1 ON4 ON

1 OFF4 OFF

4 OFF

1 OFF4 OFF

1 ON4 OFF

Original switch

Slave motorref. 2306T

Open,Apre,Ouvre,Auf,Apertura,AbreOpen,Apre,Ouvre,Auf,Apertura,Abre

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbindenNot connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

POSITIVE

Common,Comune,Comun,Je nuch Z.V.

Close,Chiude,Ferme,Zu,Cierre,Fecha

Close,Chiude,Ferme,Zu,Cierre,Fecha

Page 8: Gemini 7562

EX:AUDI A3,A6(97>),BMW 3(98),5(96>),OPEL ASTRA(98),SKODA OCTAVIA,VW GOLF,PASSAT

+30

YELLOW-BLUE

YELLOW-GREY

YELLOW-GREY

RED-BLUE

RED-BLUE

RED-BLUE

YELLOW-GREY

YELLOW-BROWN

YELLOW-BROWN

RED-GREY

RED-GREY

RED-GREY

WHITE-BLACK

RED-BROWN

RED-BROWN

YELLOW-BLUE

YELLOW-BLUE

YELLOW-BROWN

RED-BROWN

Diagram 10

Diagram 22

Diagram 23

Negative

Negative

7060

7060

7060

EX : NISSAN MICRA(>97), PRIMERA, SUBARU FORESTER, SUZUKI IGNIS, JIMMY.

EX : CITROEN XSARA, FIAT ULISSE (98), LANCIA Z (98),PEUGEOT 206, 306, 406.

Negative ComfortPositive Comfort

1

1

12

2

23

3

34

4

4

ON

ON

ON

1 OFF

4 OFF

1 OFF

1 ON

4 OFF

1

1

2

2

3

3

4

4

ON

ON

4 OFF

4 OFF

23442344

+30

WHITE-BLACKBIANCO-NEROBLANC-NOIRBLANCO-NEGROWEISS-SCHWARZ

WHITE-RED

WHITE-BROWN

PINKROSAROSE

7060

Common,Comune,Comun,Je nuch Z.V.

Open,Apre,Ouvre,Auf,Apertura,Abre

Close,Chiude,Ferme,Zu,Cierre,Fecha+ Comfort,Confort,Komfort

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Not connected, Non collegare, Ne pas brancher, No conectar, Nicht verbinden

Gemini 2344 or 2343 and Gemini 7060 interface

CENTRALDOOR

LOCKING

CENTRALDOOR

LOCKING

L.H.Sdoor

L.H.Sdoor

Page 9: Gemini 7562

7060

7060

7060

7025

7147

725

RED 5A

BLACK

BLACK

YELLOW-BLACK

YELLOW-BLACK

BLACK

BLACK

BLACK

CLAMP

BLACK marked RB

RED

Not connected

BLACK marked MB

BLACK

WHITE

15A

5A

BLACK marked R

PINK

RED

BLUE BLACK marked L

BLACK marked SGREEN

Black marked V

CLAMP

CLAMP

+

+

+_

_

_

BATTERY12VOLT

BATTERY12VOLT

BATTERY12VOLT

10A

10A

RED

RED

RED

RED

RED

RED

+30

+30

OK

NO!

NOTE:The Black wires havethe identification mark in the end.

Self-powered siren 7025 with 7060 interface

Self-powered siren 725 with 7060 interface

Supplementary siren Gemini 7147 and Gemini 7060 interface

NEGATIVE

NEGATIVE

SIREN POSITIONING

Emergency Push-botton

Emergency Push-botton


Recommended