1
Gen2 Regen Upgrade
Xizi Otis, April 2010
Summary
• Gen2 Regen ≤≤≤≤1000kg,1.75m/s configuration upgrade– Controller and drive upgrade to ACD2 MRL – E&I panel change to mini size– Introduce OTIS PM door operator NGSOK as Standard door operator – Layout changes accordingly
• Gen2 Regen extended to 2000kg, 1.75m/s – Added Regen function to 1150~2000kg as standard– Introduced Otis optimized Gen2 machine– Introduced OTIS E3 qualified HN6000 progressive safety – Other configuration (Controller& drive, E&I panel, door operator) as per Gen2 Regen ≤1000kg
• Gen2 (1150~2000kg up to 1.75m/s,Non-regen) completely phase out
Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2 sales phase out at the same time
Configuration Upgrade
� Gen2 Regen ≤1000kg configuration upgrade
� Gen2 Regen extended to 2000kg to replace GeN2
Machine Upgrade
- OTIS optimized Gen2 Machine from the samesupplier as GeN2
- Noise and vibration performance is improved- Otis Optimized Gen2 machine for ≤1000kg will be introduced later once it’s available
ABA20220AS
GeN2 GeN2-Regen
Apply to 1150kg to 2000kg Gen2 Regen only
ABA20220BD
Controller Upgrade
OH-CON4424 (For GeN2)OH-CONB604MRL(for previous Gen2 Regen up to 1000kg)
ACD2-MRL Controller
GeN2GeN2-Regen
Apply to 630kg to 2000kg Gen2 Regen
-OTIS global new controller for MRL product
-More compact
- OH-CONB604B MRL will be phase out
&Previous Gen2 Regen up to 1000kg
Regen function is added
ACD2 MRL regen drive
Apply to 630kg to 2000kg Gen2 Regen
Non-Regen drive(OH-CON4424)
Otis Regen drive for previous Gen2 Regen up to 1000kg
-OTIS global integrated regen
drive for MRL
- More compact
- OH-CONB604B MRL will be phase out
GeN2 GeN2-Regen&Previous Gen2 Regen up to 1000kg
E&I PANEL Upgrade
Min E&I PANEL
GeN2& Previous Gen2 Regen up to 1000kg
GeN2-Regen
Apply to 630kg to 2000kg Gen2 Regen
Door Operator upgrade
STD: NGSOK
- NGSOK is OTIS global PM operator - DO2000 is still optional
GeN2 GeN2-Regen
STD: AT120
Apply to 630kg to 2000kg Gen2 Regen
&Previous Gen2 Regen up to 1000kg
Safety Gear Upgrade
STD:HN6000B/C
- HN6000B/C are OTIS global E3 safety components- Bigger running clearance. Ride quality is improved and false tripping is eliminated- 9672D/E are still optional
STD:9672D/E
GeN2GeN2-Regen
Apply to 1150kg to 2000kg only
Layout Changes
New Controller & Drive Architecture
GeN2-Regen(ACD2 MRL)
New arrangement is easier for controller and drive inspection
630kg~2000kg
Previous Gen2 Regen(OH-CONB604MRL controller)
GeN2(OH-CON4424 Controller)
E&I PANEL cutout size
GeN2 GeN2-Regen
Min E&I PANEL size reduced, the cutout 1600(H)x250(W).
Top floor
Apply to 630kg to 2000kg Gen2 Regen
New Bracket Spacing for top floor
GeN2 Gen2-Regen
-Stronger rail bracket made machine more stable- Noise and vibration is improved
Top floor brackets Apply to 630kg to 2000kg Gen2 Regen
Back up
ACD2 MRL Introduction
PRODUCT DESCRIPTION
� Integrated Regen controller
�Improve aesthetics and performance
�OTIS WWE (World Wide Engineering) lead design
�OTIS global source and SSI management
210W x 540H x 90D 320W x1300H x 160D
Drive E&I Panel Controller
Duty Table
Controller Operational Parameters
75Max Rise (m)
Photo-sensorPosition Reference
Opt. GeN2Machine
Analog LWDLWD
NGSOK/AT120/AT400/DO2000
Door
OVFR2B-402,403,404,OVFR1A-406
Drive
Max 8 Car GroupOperation Control
GCS -ENBaseline Product
ValuesFeature
MRO*Rescue operation
OTIS SVTService Tool
32Maximum # of Opening
24Maximum # of Stops
2000Max Duty (kg)
1.75Max Speed (m /s)
ValuesFeature
Note: MRO function is standard. ARO function should be offered as an optional function after June 2010.
Performance
A95,11
PK-PK,14Max Vertical Vibrations (mg) @ normal speed
Average 52Noise at Top landing with door closed. (dB)
52Max In Car Noise (dB), Fan Off
± 3/ ± 5Stopping Accuracy (mm) Typical/Maximum
±5Speed Tolerance (%)
180@ 1.5m/s ~1.75m/s, 40% duty cycle
Maximum Starts Per Hour
1.0Maximum Jerk (PMT measurement: m/s3)
<1.2Maximum Acceleration (PMT measurement: m/s2)
11Max Floor Distance (m)
350 @ 1.0m/s500 @ 1.5m/s ~1.75m/s
Min. Floor Distance (mm)
TargetParameter
System Requirement
380/400/415/440Vac ±10%
50/60Hz ±2HzFrequency
Supply Voltage
� Power Supply
Note: TN-S (five wires net = 3 phases +neutral +earth)For 220/460V power supply, there need an extended additional transformer in system.
Application Environment
� Max Elevation: – 1000m: full performance– 2000m: Reduced performance(1% of rated running current per 100m)
� Operating Humidity
– 95% non-condensing
� Operating Temperature range (machine room):– 0~45℃
Product Advantages
� Operational controller based on GECB (Global Elevator Control Board)
+ Motion controller based on GDCB (Global Drive Control Board)
� CAN-bus communication interface between operational and motion controllers
� External system interface following global SIMBA
� Energy effectiveness from the regenerative drive
� Mini E&I Panel
� Easily expandable computing core with high-speed 32bit CPU