STAIR TOWER NOTES: 1. STAIR TOWER IS DESIGNED FOR ACCESS AND EGRESS FOR THE PUBLIC. 2. PLATFORM LIVE LOAD SHALL NOT EXCEED THE LESSER OF THE TOTAL LIVE LOAD OR LIVE LOAD RATING. A. STAIR TOWER LIVE LOAD RATING = 100 PSF (EGRESS) B. ROOF LOADING = 25 PSF (SNOW + RAIN) C. WIND LOADING = 25.8 PSF 3. STAIR TOWER IS NOT DESIGNED FOR ANY WORKING LEVEL(S). 4. MAXIMUM CALCULATED SCAFFOLD LEG LOAD = 7,100 LBS. 5. ALL END FRAMES SHALL BE TIED TO THE STRUCTURE OR PERPENDICULAR SCAFFOLD SHALL BE RUN, REGARDLESS OF HORIZONTAL TIE SPACING AT THAT POINT. 6. ALL TOP FRAMES SHALL BE TIED TO THE STRUCTURE, REGARDLESS OF VERTICAL TIE SPACING AT THAT POINT. GENERAL SCAFFOLD NOTES: 1. SCAFFOLD DESIGN BASED ON UNIVERSAL MANUFACTURING SYSTEMS SCAFFOLD , U.N.O. 2. SCAFFOLD HEIGHT SHALL NOT EXCEED THE HEIGHTS SPECIFIED IN THIS DRAWING SET U.N.O. 3. MAXIMUM SCREW EXTENSION = 12" EACH SCREW 4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO USE ADEQUATE TIMBER SILLS TO ENSURE SCAFFOLD STABILITY AND PROPER LOAD DISTRIBUTION. 5. ALL PLANK SHALL BE SECURED TO SCAFFOLDING BY THE CONTRACTOR. SCAFFOLD PLATFORMS SHALL BE CONSTRUCTED WITH ONE OR MORE OF THE FOLLOWING (DEAD LOAD ~ 5 PSF): A. 2x10 MICROLAM OR SOLID SAWN SCAFFOLD GRADE PLANK AND 3/4" THICK PLYWOOD FILLERS (NOT TO BE USED ON STAIR TOWERS, U.N.O.) B. STEEL OR ALUMINUM HOOK PLANK 6. FRAME STACKUP AND PLATFORM ELEVATIONS MAY VARY SLIGHTLY FROM DRAWING BUT FRAMES MUST BE BRACED EVERY TIER IN ONE DIRECTION MINIMUM, U.N.O. 7. HORIZONTAL BRACING SHALL NOT EXCEED 6' - 6" VERTICAL SPACING U.N.O. 8. DIAGONAL BRACING SHALL BE INSTALLED AT EVERY TIER IN EVERY 3RD BAY IN (2) ADJACENT DIRECTIONS, MIN. 9. VERTICAL DIAGONAL BRACING SHALL MATCH HORIZONTAL BAR SPACING. CONTRACTOR TO ENSURE VERTICAL DIAGONAL BRACES DO NOT CONNECT TO THE SCAFFOLD LEGS WHERE THERE ARE NO HORIZONTAL BRACES PRESENT TO DISTRIBUTE THE LOADS. 10. SNOW, DUST, DIRT OR ANY OTHER FALLING OR WIND - BLOWN MATERIAL SHALL BE REMOVED FROM SCAFFOLD AS IT ACCUMULATES. 11. IF SCAFFOLD BEARS ON ANY STRUCTURE, THE OWNER OR ENGINEER OF RECORD SHALL VERIFY THAT THE EXISTING STRUCTURE IS CAPABLE OF SUPPORTING LOADS IMPOSED BY THE SCAFFOLD DEAD AND LIVE LOADS. 12. SCAFFOLDING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MANUFACTURERS DIRECTIONS & RECOMMENDATIONS. 1. DESIGN WORK ON THIS PROJECT HAS BEEN COMPLETED IN ACCORDANCE WITH THE FOLLOWING CODES: OSSC 2014 ASCE 7 - 10 2. VERTICAL LIVE LOADS STAIR TOWER LIVE LOAD: 100 PSF OVERHEAR PROTECTION LIVE LOAD 150 PSF 3. WIND PARAMETERS RISK CATEGORY: II, I = 1.0 EXPOSURE CATEGORY: C BASIC WIND SPEED: 120 MPH (ASCE 7 - 10) 4. SEISMIC PARAMETERS SDS: 0.712 SITE CLASS: D OCCUPANCY CATEGORY: II SEISMIC DESIGN CATEGORY: D Cs: 0.285 SYSTEM: STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE (R = 3) ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE 5. SOIL BEARING 1,500 PSF IN LIEU OF SOILS REPORT DESIGN CRITERIA: SEAL: DESCRIPTION: DATE: REVISIONS: CLIENT: PROJECT: SHEET TITLE: PROJECT #: DRAWN BY: CHECKED BY: DATE: SHEET: SCALE: ©2017 CRIMSON ENGINEERING ASSOCIATES, INC. (CEA) | DOCUMENT REUSE: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CEA AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CEA. E Crimson Engineering Associates, Inc. Denver, Colorado P: 720.502.4667 | F: 303.974.1734 www.CrimsonEngineering.com 0 1" U.N.O.......UNLESS NOTED OTHERWISE MIN.................................................MINIMUM MAX...............................................MAXIMUM TYP....................................................TYPICAL SIM.....................................................SIMILAR DBL....................................................DOUBLE (E)....................................................EXISTING (N).............................................................NEW O.C...............................................ON CENTER C/C...........................CENTER-TO-CENTER T.O., T/................................................TOP OF BOT...................................................BOTTOM B.O., B/......................................BOTTOM OF SOG....................................SLAB ON GRADE T&B.....................................TOP & BOTTOM ALUM..........................................ALUMINUM M.E. ...................................MINIMUM EDGE T.R. ....................................THREADED ROD CIP ......................................CAST-IN-PLACE PL ..........................................................PLATE L ..............................STRUCTURAL ANGLE ABV.......................................................ABOVE BTWN...........................................BETWEEN CLR............................CLEAR/CLEARANCE .....................................................DIAMETER ±.........................................PLUS-OR-MINUS EQ............................EQUAL/EQUIVALENT FND........................................FOUNDATION LBS.....................................................POUNDS PSI..............POUNDS PER SQUARE INCH PSF............POUNDS PER SQUARE FOOT PLF.............POUNDS PER LINEAR FOOT N.T.S.....................................NOT TO SCALE REQ'D...........................................REQUIRED THK.............................THICK/THICKNESS V.I.F..................................VERIFY IN FIELD EOR....................ENGINEER-OF-RECORD LOCATION MAP CEA PROJECT #: PROJECT NAME: PROJECT ADDRESS: LEGEND TABLE OF CONTENTS PROJECT INFORMATION CEA CLIENT: CLIENT ADDRESS: GENERAL CONTRACTOR: 1. "CEA" SHALL REFER TO CRIMSON ENGINEERING ASSOCIATES, INC. 2. "CONTRACTOR" SHALL REFER TO 3. "OTHERS" SHALL REFER TO THE GENERAL CONTRACTOR OR RESPONSIBLE PARTY FOR THE PROJECT. 4. ANY OVERALL PROJECT DETAILS NOT SPECIFIED IN THIS DRAWING SET ARE NOT THE RESPONSIBILITY OF CEA. 5. A SET OF THE LATEST PLANS SHALL BE ON SITE DURING CONSTRUCTION. 6. DIMENSIONED OR CALLED - OUT MEASUREMENTS SHALL BE USED IN LIEU OF SCALED MEASUREMENTS. 7. THE DESIGN HEREIN IS VALID ONLY FOR THE PROJECT, LOCATION AND PHASE LISTED AND SHALL NOT BE RE - CREATED FOR ANY OTHER SITUATIONS. 8. CONTRACTOR IS TO CONFIRM ALL SIZES, DIMENSIONS & ELEVATIONS PRIOR TO ORDERING OR ERECTING EQUIPMENT. GENERAL NOTES: 9. ALL ACCESS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ALL APPLICABLE SITE, LOCAL, STATE & FEDERAL CODES AND OSHA REGULATIONS. 10. ALL OPEN SIDES AND ENDS OF WORK LEVELS SHALL BE PROTECTED WITH GUARDRAILS AND TOEBOARDS OR WORKERS SHALL BE 100% TIED OFF TO A STRUCTURAL MEMBER CAPABLE OF HAVING A FALL LOAD SAFELY EXERTED UPON IT. 11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE NO SCAFFOLD OR SHORING LOADS BEAR IN AREAS WITH UNDERGROUND UTILITIES. 12. IF ANY DISCREPANCIES THAT IMPACT CONSTRUCTION ARE OBSERVED BETWEEN THIS DRAWING SET AND FIELD CONDITIONS, CONTRACTOR SHALL STOP WORK AND CONTACT CEA WITH THE DISCREPANCY. 13. THE DESIGN IN THIS DRAWING SET IS BASED UPON DRAWING SET BY: DATED: SEE DRAWING SET FOR ADDITIONAL INFORMATION. PEDESTRIAN STAIR TOWER PORTLAND INTERNATIONAL AIRPORT TITLE SHEET & GENERAL NOTES 195102 KAD SB 12/22/2019 0.0 SDB CONTRACTING SERVICES 8125 NE CHERRY DR. HILLSBORO, OR 97124 195102 PEDESTRIAN STAIR TOWER PORTLAND INTERNATIONAL AIRPORT SDB CONTRACTING SERVICES 8125 NE CHERRY DR. HILLSBORO, OR 97124 N/A SDB CONTRACTING SERVICES. UNIVERSAL MANUFACTURING 6/24/19 SHEET# DESCRIPTION 0.0 TITLE SHEET & GENERAL NOTES 0.1 STANDARD DETAILS 1.0 PLAN VIEWS 2.0 SECTIONS 3.0 HANDRAIL END CONNECTORS SITE A 8/13/2019 FOR R EVIEW B 8/15/2019 ISSUE D FOR CONS TRUCTION C 12/22/19 PLAN CHECK C 12/23/2019
Transcript
Page 1: GENERAL SCAFFOLD NOTES: LOCATION MAP

STAIR TOWER NOTES:

1. STAIR TOWER IS DESIGNED FOR ACCESS AND EGRESS FOR THE PUBLIC.

2. PLATFORM LIVE LOAD SHALL NOT EXCEED THE LESSER OF THE TOTAL LIVE LOAD OR LIVE LOAD RATING.

A. STAIR TOWER LIVE LOAD RATING = 100 PSF (EGRESS)

B. ROOF LOADING = 25 PSF (SNOW + RAIN)

C. WIND LOADING = 25.8 PSF

3. STAIR TOWER IS NOT DESIGNED FOR ANY WORKING LEVEL(S).

4. MAXIMUM CALCULATED SCAFFOLD LEG LOAD = 7,100 LBS.

5. ALL END FRAMES SHALL BE TIED TO THE STRUCTURE OR PERPENDICULAR SCAFFOLD SHALL BE RUN,

REGARDLESS OF HORIZONTAL TIE SPACING AT THAT POINT.

6. ALL TOP FRAMES SHALL BE TIED TO THE STRUCTURE, REGARDLESS OF VERTICAL TIE SPACING AT THAT

POINT.

GENERAL SCAFFOLD NOTES:

1. SCAFFOLD DESIGN BASED ON UNIVERSAL MANUFACTURING SYSTEMS SCAFFOLD, U.N.O.

2. SCAFFOLD HEIGHT SHALL NOT EXCEED THE HEIGHTS SPECIFIED IN THIS DRAWING SET U.N.O.

3. MAXIMUM SCREW EXTENSION = 12" EACH SCREW

4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO USE ADEQUATE TIMBER SILLS TO ENSURE SCAFFOLD

STABILITY AND PROPER LOAD DISTRIBUTION.

5. ALL PLANK SHALL BE SECURED TO SCAFFOLDING BY THE CONTRACTOR. SCAFFOLD PLATFORMS SHALL

BE CONSTRUCTED WITH ONE OR MORE OF THE FOLLOWING (DEAD LOAD ~ 5 PSF):

A. 2x10 MICROLAM OR SOLID SAWN SCAFFOLD GRADE PLANK AND 3/4" THICK PLYWOOD FILLERS

(NOT TO BE USED ON STAIR TOWERS, U.N.O.)

B. STEEL OR ALUMINUM HOOK PLANK

6. FRAME STACKUP AND PLATFORM ELEVATIONS MAY VARY SLIGHTLY FROM DRAWING BUT FRAMES

MUST BE BRACED EVERY TIER IN ONE DIRECTION MINIMUM, U.N.O.

7. HORIZONTAL BRACING SHALL NOT EXCEED 6'-6" VERTICAL SPACING U.N.O.

8. DIAGONAL BRACING SHALL BE INSTALLED AT EVERY TIER IN EVERY 3RD BAY IN (2) ADJACENT

DIRECTIONS, MIN.

9. VERTICAL DIAGONAL BRACING SHALL MATCH HORIZONTAL BAR SPACING. CONTRACTOR TO ENSURE

VERTICAL DIAGONAL BRACES DO NOT CONNECT TO THE SCAFFOLD LEGS WHERE THERE ARE NO

HORIZONTAL BRACES PRESENT TO DISTRIBUTE THE LOADS.

10. SNOW, DUST, DIRT OR ANY OTHER FALLING OR WIND-BLOWN MATERIAL SHALL BE REMOVED FROM

SCAFFOLD AS IT ACCUMULATES.

11. IF SCAFFOLD BEARS ON ANY STRUCTURE, THE OWNER OR ENGINEER OF RECORD SHALL VERIFY THAT

THE EXISTING STRUCTURE IS CAPABLE OF SUPPORTING LOADS IMPOSED BY THE SCAFFOLD DEAD AND

LIVE LOADS.

12. SCAFFOLDING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MANUFACTURERS

DIRECTIONS & RECOMMENDATIONS.

1. DESIGN WORK ON THIS PROJECT HAS BEEN COMPLETED IN ACCORDANCE

WITH THE FOLLOWING CODES:

OSSC 2014

ASCE 7-10

2. VERTICAL LIVE LOADS

STAIR TOWER LIVE LOAD: 100 PSF

OVERHEAR PROTECTION LIVE LOAD 150 PSF

3. WIND PARAMETERS

RISK CATEGORY: II, I = 1.0

EXPOSURE CATEGORY: C

BASIC WIND SPEED: 120 MPH (ASCE 7-10)

4. SEISMIC PARAMETERS

SDS: 0.712

SITE CLASS: D

OCCUPANCY CATEGORY: II

SEISMIC DESIGN CATEGORY: D

Cs: 0.285

SYSTEM: STEEL SYSTEM NOT SPECIFICALLY DETAILED

FOR SEISMIC RESISTANCE (R = 3)

ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE

5. SOIL BEARING 1,500 PSF IN LIEU OF SOILS REPORT

DESIGN CRITERIA:

SEAL:

DE

SC

RIP

TIO

N:

DA

TE

:

RE

VIS

ION

S:

CL

IEN

T:

PR

OJE

CT

:

SH

EE

T T

ITL

E:

PROJECT #:

DRAWN BY:

CHECKED BY:

DATE:

SHEET:

SCALE:

©2

01

7 C

RIM

SO

N E

NG

INE

ER

ING

AS

SO

CIA

TE

S,

INC

. (C

EA

) |

DO

CU

ME

NT

RE

US

E:

TH

IS D

OC

UM

EN

T,

AN

D T

HE

ID

EA

S A

ND

DE

SIG

NS

IN

CO

RP

OR

AT

ED

HE

RE

IN,

AS

AN

IN

ST

RU

ME

NT

OF

PR

OF

ES

SIO

NA

L S

ER

VIC

E,

IS T

HE

PR

OP

ER

TY

OF

CE

A A

ND

IS

NO

T T

O B

E U

SE

D,

IN W

HO

LE O

R I

N P

AR

T,

FO

R A

NY

OT

HE

R P

RO

JEC

T W

ITH

OU

T T

HE

WR

ITT

EN

AU

TH

OR

IZA

TIO

N O

F C

EA

.

E

Crimson Engineering

Associates, Inc.

Denver, Colorado

P: 720.502.4667 | F: 303.974.1734

www.CrimsonEngineering.com

0 1"

U.N.O.......UNLESS NOTED OTHERWISE

MIN.................................................MINIMUM

MAX...............................................MAXIMUM

TYP....................................................TYPICAL

SIM.....................................................SIMILAR

DBL....................................................DOUBLE

(E)....................................................EXISTING

(N).............................................................NEW

O.C...............................................ON CENTER

C/C...........................CENTER-TO-CENTER

T.O., T/................................................TOP OF

BOT...................................................BOTTOM

B.O., B/......................................BOTTOM OF

SOG....................................SLAB ON GRADE

T&B.....................................TOP & BOTTOM

ALUM..........................................ALUMINUM

M.E. ...................................MINIMUM EDGE

T.R. ....................................THREADED ROD

CIP ......................................CAST-IN-PLACE

PL ..........................................................PLATE

L ..............................STRUCTURAL ANGLE

ABV.......................................................ABOVE

BTWN...........................................BETWEEN

CLR............................CLEAR/CLEARANCE

∅.....................................................DIAMETER

±.........................................PLUS-OR-MINUS

EQ............................EQUAL/EQUIVALENT

FND........................................FOUNDATION

LBS.....................................................POUNDS

PSI..............POUNDS PER SQUARE INCH

PSF............POUNDS PER SQUARE FOOT

PLF.............POUNDS PER LINEAR FOOT

N.T.S.....................................NOT TO SCALE

REQ'D...........................................REQUIRED

THK.............................THICK/THICKNESS

V.I.F..................................VERIFY IN FIELD

EOR....................ENGINEER-OF-RECORD

LOCATION MAP

CEA PROJECT #:

PROJECT NAME:

PROJECT ADDRESS:

LEGEND

TABLE OF CONTENTS

PROJECT INFORMATION

CEA CLIENT:

CLIENT ADDRESS:

GENERAL CONTRACTOR:

1. "CEA" SHALL REFER TO CRIMSON ENGINEERING ASSOCIATES, INC.

2. "CONTRACTOR" SHALL REFER TO

3. "OTHERS" SHALL REFER TO THE GENERAL CONTRACTOR OR

RESPONSIBLE PARTY FOR THE PROJECT.

4. ANY OVERALL PROJECT DETAILS NOT SPECIFIED IN THIS DRAWING

SET ARE NOT THE RESPONSIBILITY OF CEA.

5. A SET OF THE LATEST PLANS SHALL BE ON SITE DURING

CONSTRUCTION.

6. DIMENSIONED OR CALLED-OUT MEASUREMENTS SHALL BE USED IN

LIEU OF SCALED MEASUREMENTS.

7. THE DESIGN HEREIN IS VALID ONLY FOR THE PROJECT, LOCATION

AND PHASE LISTED AND SHALL NOT BE RE-CREATED FOR ANY

OTHER SITUATIONS.

8. CONTRACTOR IS TO CONFIRM ALL SIZES, DIMENSIONS &

ELEVATIONS PRIOR TO ORDERING OR ERECTING EQUIPMENT.

GENERAL NOTES:9. ALL ACCESS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE

WITH ALL APPLICABLE SITE, LOCAL, STATE & FEDERAL CODES AND

OSHA REGULATIONS.

10. ALL OPEN SIDES AND ENDS OF WORK LEVELS SHALL BE PROTECTED

WITH GUARDRAILS AND TOEBOARDS OR WORKERS SHALL BE 100%

TIED OFF TO A STRUCTURAL MEMBER CAPABLE OF HAVING A FALL

LOAD SAFELY EXERTED UPON IT.

11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE NO SCAFFOLD

OR SHORING LOADS BEAR IN AREAS WITH UNDERGROUND

UTILITIES.

12. IF ANY DISCREPANCIES THAT IMPACT CONSTRUCTION ARE

OBSERVED BETWEEN THIS DRAWING SET AND FIELD CONDITIONS,

CONTRACTOR SHALL STOP WORK AND CONTACT CEA WITH THE

DISCREPANCY.

13. THE DESIGN IN THIS DRAWING SET IS BASED UPON DRAWING SET

BY:

DATED:

SEE DRAWING SET FOR ADDITIONAL INFORMATION.

PE

DE

ST

RIA

N S

TA

IR T

OW

ER

PO

RT

LAN

D I

NT

ER

NA

TIO

NA

L

AIR

PO

RT

TIT

LE S

HE

ET

& G

EN

ER

AL

NO

TE

S

195102

KAD

SB

12/22/2019

0.0

SD

B C

ON

TR

AC

TIN

G S

ER

VIC

ES

81

25

NE

CH

ER

RY

DR

.

HIL

LSB

OR

O,

OR

97

12

4

195102

PEDESTRIAN STAIR TOWER

PORTLAND INTERNATIONAL

AIRPORT

SDB CONTRACTING SERVICES

8125 NE CHERRY DR.

HILLSBORO, OR 97124

N/A

SDB CONTRACTING SERVICES.

UNIVERSAL MANUFACTURING

6/24/19

SHEET# DESCRIPTION

0.0 TITLE SHEET & GENERAL NOTES

0.1 STANDARD DETAILS

1.0 PLAN VIEWS

2.0 SECTIONS

3.0 HANDRAIL END CONNECTORSSITE

A8

/13

/20

19

FO

R R

EV

IEW

B8

/15

/20

19

ISS

UE

D F

OR

CO

NS

TR

UC

TIO

N

C1

2/2

2/1

9P

LAN

CH

EC

K

C

12/23/2019

Page 2: GENERAL SCAFFOLD NOTES: LOCATION MAP

1. NOT ALL MATERIALS LISTED BELOW MAY BE ADEQUATE FOR PROJECT SCOPE. SEE PLAN

FOR REQUIRED MATERIALS.

2. CONCRETE DENSITY IS ASSUMED TO BE 150 PCF FOR PURPOSES OF DEAD LOAD

CALCULATIONS AND CAST-IN-PLACE SHORING LOADING, U.N.O.

3. CONCRETE SHALL BE AIR-ENTRAINED TO 5% +/- 1%.

4. REINFORCEMENT SHALL BE PER ASTM A615 GRADE 40 ksi, U.N.O.

5. ALL SLABS ON GRADE (S.O.G.) HAVE BEEN DESIGNED ASSUMING AN f'c OF 2500 psi,

HOWEVER THEY SHALL BE CONSTRUCTED WITH 3500 psi CONCRETE.

6. REINFORCEMENT COVER IN CAST-IN-PLACE CONCRETE SHALL BE AS FOLLOWS:

• 3" - CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH.

• 1-1/2" - CONCRETE EXPOSED TO EARTH OR WEATHER WITH #5 BARS OR

SMALLER.

• 1-1/2" - CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND,

#11 BARS AND SMALLER.

• 1-1/2" - CLEAR TO TOP FOR REINFORCEMENT IN SLABS ON GRADE.

7. TIMBER SILLS FOR SCAFFOLD LEGS SHALL BE: 2x10x 12" LONG, U.N.O.

8. TIMBER SILLS FOR SHORING TOWERS SHALL BE:

• SLAB ON GRADE = 2x10x 12" LONG

• GRADE (SOIL OR ASPHALT) = 2x10x 2'X2' SQUARE

9. STEEL BEAMS SHALL BE A-36, Fy-36 KSI, MINIMUM.

10. ALUMINUM BEAMS SHALL BE 6061-T6, Fy=35 KSI, MINIMUM, AND INDICATED AS:

• 'X'-AS: 7.5" DEEP x 4" WIDE ALUMINUM STRINGER AT 'X' FEET IN LENGTH. (MIN

I/x= 34.5)

• 'X'-AJ: 6.5" DEEP ALUMINUM JOIST AT 'X' FEET IN LENGTH. (MIN I/x= 16.6)

11. TIMBER BEAMS/JOISTS SHALL BE DOUGLAS FIR #2, (OR BETTER), WITH THE FOLLOWING

PROPERTIES, MINIMUM. ADJUSTMENT FACTORS MAY BE APPLIED TO THESE

PROPERTIES.

• ALLOWABLE SHEAR STRESS: Fv= 180 PSI

• ALLOWABLE BENDING STRESS: Fb= 850 PSI

• MODULUS OF ELASTICITY: E= 1,600,000 PSI

12. PLYWOOD DESIGN IS BASED ON AMERICAN PLYWOOD ASSOCIATION

RECOMMENDATIONS. THE FACE OF THE PLYWOOD GRAIN SHALL RUN AT RIGHT

ANGLES (90°) TO ITS SUPPORTS, WITH 2 OR MORE SUPPORTS PER SHEET.

13. 2x10 SCAFFOLD PLANK SHALL BE LVL TYPE AND HAVE THE FOLLOWING PROPERTIES,

MINIMUM.

• ALLOWABLE SHEAR STRESS: Fv = 145 PSI

• ALLOWABLE BENDING STRESS: Fb = 2,900 PSI

• MODULUS OF ELASTICITY: E = 2,200,000 PSI

14. THREADED RODS SHALL BE HIGH-TENSILE, UNIFIED NATIONAL COARSE (UNC), GRADE

ASTM A193 B-7, OR EQUIVALENT.

15. STAINLESS STEEL HARDWARE SHALL BE TYPE 304, U.N.O.

16. WELDING SHALL BE PERFORMED BY A QUALIFIED PERSON USING E70XX ELECTRODES,

MIN, AND INSPECTED BY A CERTIFIED WELDING INSPECTOR (CWI), U.N.O.

17. THE "TURN-OF-THE-NUT" METHOD MAY BE USED IN LIEU OF A TORQUE WRENCH

WHEN BOTH CONNECTING FACES ARE PERPENDICULAR TO THE BOLT AXIS. NUT SHALL

BE INSTALLED TO A "HAND-TIGHT" CONDITION AND THEN TIGHTENED WITH A

WRENCH, IN RELATION TO THE BOLT, BY THE ROTATION DISTANCES LISTED.

MATERIALS NOTES:

ROTATION

DISTANCE

1/3TURN

1/2TURN

2/3TURN

BOLT LENGTH

3/8"BOLT ∅ 1/2

" 5/8" 3/4

"

0"-11/2" 0" - 2" 0" - 21/2

" 0" - 3"

1 1/2" - 3" 2"- 4" 2 1/2" - 5" 3" - 6"

3"- 4 1/2" 4" - 6" 5" - 71/2

" 6" - 9"

SEAL:

DE

SC

RIP

TIO

N:

DA

TE

:

RE

VIS

ION

S:

CL

IEN

T:

PR

OJE

CT

:

SH

EE

T T

ITL

E:

PROJECT #:

DRAWN BY:

CHECKED BY:

DATE:

SHEET:

SCALE:

©2

01

7 C

RIM

SO

N E

NG

INE

ER

ING

AS

SO

CIA

TE

S,

INC

. (C

EA

) |

DO

CU

ME

NT

RE

US

E:

TH

IS D

OC

UM

EN

T,

AN

D T

HE

ID

EA

S A

ND

DE

SIG

NS

IN

CO

RP

OR

AT

ED

HE

RE

IN,

AS

AN

IN

ST

RU

ME

NT

OF

PR

OF

ES

SIO

NA

L S

ER

VIC

E,

IS T

HE

PR

OP

ER

TY

OF

CE

A A

ND

IS

NO

T T

O B

E U

SE

D,

IN W

HO

LE O

R I

N P

AR

T,

FO

R A

NY

OT

HE

R P

RO

JEC

T W

ITH

OU

T T

HE

WR

ITT

EN

AU

TH

OR

IZA

TIO

N O

F C

EA

.

E

Crimson Engineering

Associates, Inc.

Denver, Colorado

P: 720.502.4667 | F: 303.974.1734

www.CrimsonEngineering.com

0 1"

PE

DE

ST

RIA

N S

TA

IR T

OW

ER

PO

RT

LAN

D I

NT

ER

NA

TIO

NA

L

AIR

PO

RT

ST

AN

DA

RD

DE

TA

ILS

195102

KAD

SB

12/22/2019

0.1

SD

B C

ON

TR

AC

TIN

G S

ER

VIC

ES

81

25

NE

CH

ER

RY

DR

.

HIL

LSB

OR

O,

OR

97

12

4

A8

/13

/20

19

FO

R R

EV

IEW

B8

/15

/20

19

ISS

UE

D F

OR

CO

NS

TR

UC

TIO

N

C1

2/2

2/1

9P

LAN

CH

EC

K

SCALE: 1" = 1'-0"

STAIR AND GUARDRAIL DETAILS2

C

SCALE: 1" = 1'-0"

BAR TO LEG CONNECTION1

C

12/23/2019

Page 3: GENERAL SCAFFOLD NOTES: LOCATION MAP

C2.0

_______

A2.0

_______

20' - 0"

INDICATES TRUSSED

MEMBER, TYP

INDICATES STAIR

STRINGER, TYP.

SCREWJACK AND

BASEPLATE, TYP. TURN- AROUND BAY

TURN- AROUND BAY

12

' - 0

"

8" CONRETE SLAB

WITH TURNDOWN

FOOTINGS AT

PERIMETER

4

1.0

TYP.

1.0

5

TYP. AT

ALL LEGS

C

C

B2.0

_______

F2.0

_______

UP

T T

T T

T T

BASE LEVEL.

D2.0

_______

E2.0

_______

5'

4'

INDICATES TRUSSED

MEMBER, TYP

INDICATES STAIR

STRINGER, TYP.

SCREWJACK &

BASEPLATE, TYP.

T

T

T

T

T

T

T

DOWN

DO

WN

5' -

0"

5' -

0"

5' - 0" 8' - 0" 5' - 0"

5' -

0"

(E) WALL.

LEVEL 1 SLAB.

4' - 6"CLEAR

LANDING

WIDTH

CLE

AR

LA

ND

ING

LE

NG

TH

9' -

6"

10

' - 0

"

3'-

8"

CLR

.

CLEAR DIST. BETWEEN

HANDRAILS

C

4'x5' LEVEL PLATFORM,

DIAMOND PLATE OVER

STACKED STEEL

SCAFFOLD PLANK, 6"

MAX. HEIGHT

C

5'

4'

0' -

3"

CLR

.

#4 BAR, CONT.

#4 AT 12" O/C, BOTH WAYS

0' -

6"

EX. GRADE

1' -

6"

8" CONCRETE SLAB OVER

COMPACTED PAD

1' - 0"

RETAINER CLIP,

JACK HANDLE

TO LEG

SEAL:

DE

SC

RIP

TIO

N:

DA

TE

:

RE

VIS

ION

S:

CL

IEN

T:

PR

OJE

CT

:

SH

EE

T T

ITL

E:

PROJECT #:

DRAWN BY:

CHECKED BY:

DATE:

SHEET:

SCALE:

©2

01

7 C

RIM

SO

N E

NG

INE

ER

ING

AS

SO

CIA

TE

S,

INC

. (C

EA

) |

DO

CU

ME

NT

RE

US

E:

TH

IS D

OC

UM

EN

T,

AN

D T

HE

ID

EA

S A

ND

DE

SIG

NS

IN

CO

RP

OR

AT

ED

HE

RE

IN,

AS

AN

IN

ST

RU

ME

NT

OF

PR

OF

ES

SIO

NA

L S

ER

VIC

E,

IS T

HE

PR

OP

ER

TY

OF

CE

A A

ND

IS

NO

T T

O B

E U

SE

D,

IN W

HO

LE O

R I

N P

AR

T,

FO

R A

NY

OT

HE

R P

RO

JEC

T W

ITH

OU

T T

HE

WR

ITT

EN

AU

TH

OR

IZA

TIO

N O

F C

EA

.

E

Crimson Engineering

Associates, Inc.

Denver, Colorado

P: 720.502.4667 | F: 303.974.1734

www.CrimsonEngineering.com

0 1"

PE

DE

ST

RIA

N S

TA

IR T

OW

ER

PO

RT

LAN

D I

NT

ER

NA

TIO

NA

L

AIR

PO

RT

PLA

N V

IEW

S

195102

KAD

SB

12/22/2019

1.0

SD

B C

ON

TR

AC

TIN

G S

ER

VIC

ES

81

25

NE

CH

ER

RY

DR

.

HIL

LSB

OR

O,

OR

97

12

4

SCALE: 1/4" = 1'-0"

BASE LVL1

SCALE: 1/4" = 1'-0"

LVL 12

A8

/13

/20

19

FO

R R

EV

IEW

B8

/15

/20

19

ISS

UE

D F

OR

CO

NS

TR

UC

TIO

N

C1

2/2

2/1

9P

LAN

CH

EC

K

SCALE: 1" = 1'-0"

FOOTING AT SLAB EDGE4

SCALE: 3/4" = 1'-0"

SCAFFOLD ANCHORAGE TO SLAB5

CC

SCALE: NOT TO SCALE (N.T.S.)

ISO VIEWi

12/23/2019

Page 4: GENERAL SCAFFOLD NOTES: LOCATION MAP

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

A2.0

_______B2.0

_______

4'x5' LEVEL PLATFORM,

DIAMOND PLATE OVER

STACKED STEEL SCAFFOLD

PLANK, 6" MAX. HEIGHT

0.1

2TYP.

C

4'

5' STAIR TREAD ASSEMBLY

(USSL50-IBC, USSR50-IBC, UST40T-IBC,

UST40-IBC, 05141, 05142), TYP.

USSL50HR-IBC

USSR50HR-IBC

UD

50

UH50

UH50

UH50

UH50

UD

50U

D50

UD

50

UH50

UH50

UH50

UH50

UD

50

UD

50

UH50GR-

IBC, TYP. 5'

GUARDRAIL

PANEL

(2) US99,

(1) US33

LEG, TYP. UD

50

UH50

USJ20,

TYP.0.1

1

TYP.

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

C2.0

_______

SYSTEMS SCAFFOLD, BY

UNIVERSAL MANUFACTURING,

OR EQUIVALENT, TYP.

SCAFFOLD PLANK TO

BEAR ON TRUSSES, TYP.

F2.0

_______

INSTALL OFF-SET BAR

AS NEEDED FOR HEAD

CLEARANCE, TYP.

1.0

5

1.0

4

TYP. AT ALL LEGS

TYP.

C

HANDRAIL EXTENSIONS AT

TOP & BOTTOM OF RAILS TO

COMPLY WITH 1012.6,

DETAILS PER SHEET 3.0

3' - 8"

CLEAR DIST. BETWEEN

HANDRAILS

D2.0

_______E2.0

_______

UD80

UH80UH50 UH50

USSL80HR-IBC

USSR80HR-IBC

UH50GR-IBC

8' STAIR TREAD ASSEMBLY

(USSL80-IBC, USSR80-IBC,

UST40T-IBC, UST40-IBC,

08141, 08142), TYP.

(2) US99,

(1) US33

LEG, TYP.

USJ20, TYP.

UH50GR-IBC

UD80

UD80

UH80

UH80

UH80

UH50

UH50UHT50

UHT50

UHT50

UHT50HB-IBC

0.1

1TYP.

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

C2.0

_______F2.0

_______

HO

RIZ

ON

TA

L B

RA

CIN

G I

N T

WO

DIR

EC

TIO

NS

6'-

6"

MA

X.

BE

TW

EE

N

15

' - 0

" ±

5"

±

D2.0

_______E2.0

_______

CENTER LEG-LINE BARCE

RAISED ONE RING.

UHT50

UHT50

UHT50

UHT50

UD

50

UD80

UD80

UD80

UD5033

UD5033

UH80

UH50

UH50

UH80

UH80

UH80

UH50

UH50 UH50

UH50

(2) US99,

(1) US33

LEG, TYP.

USJ20,

TYP.

ADDED LABELS

FOR SCAFFOLD

COMPONENTS TO

SECTION VIEWS

C

USSL80HR-IBC

USSR80HR-IBC

UH50GR-IBC

UH50GR-IBC

UH50GR-IBC

UH50GR-IBC

USSL50HR-IBC

USSR50HR-IBC

8' STAIR TREAD ASSEMBLY

(USSL80-IBC, USSR80-IBC,

UST40T-IBC, UST40-IBC,

08141, 08142), TYP.

5' STAIR TREAD ASSEMBLY

(USSL50-IBC, USSR50-IBC,

UST40T-IBC, UST40-IBC,

05141, 05142), TYP.

0.1

1

TYP.

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

A2.0

_______B2.0

_______

DIAMOND PLATE ON

STEEL PLANK TO

LEVEL STAIRS

C

4'

UD

50

UH50

UH50

UH50

UH50

UD

50U

D50

UD

50

UH50

UH50

UH50

UH50

UD

50U

D50

3' STAIR TREAD ASSEMBLY

(USSL30-IBC, USSR30-IBC, UST40T-IBC,

UST40-IBC, 03141, 03142), TYP.

USSL30HR-IBC

USSR30HR-IBC

UH50GR-

IBC, TYP. 5'

GUARDRAIL

PANEL

(2) US99,

(1) US33

LEG, TYP.

USJ20,

TYP.

0.1

1

TYP.

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

A2.0

_______B2.0

_______

DIAMOND PLATE ON

STEEL PLANK TO

LEVEL STAIRS

C

4'

UH50

3' STAIR TREAD ASSEMBLY

(USSL30-IBC, USSR30-IBC, UST40T-IBC,

UST40-IBC, 03141, 03142), TYP.

USSL30HR-IBC

USSR30HR-IBC

UD

50

UH50

UH50HB-IBC

UH50

UH50

UH50

UD

50

UD

50U

D50

UH50

UH50

UH50

(2) US99,

(1) US33

LEG, TYP.

USJ20,

TYP.

0.1

1TYP.

BASE LVL

0' - 0"

LVL 1

11' - 2"

LVL 2

23' - 0"

A2.0

_______B2.0

_______

4'x5' LEVEL PLATFORM, DIAMOND

PLATE OVER STACKED STEEL

SCAFFOLD PLANK, 6" MAX. HEIGHT

0.1

2TYP.

C

4'

UH50GR-IBC

USSL50HR-IBC

USSR50HR-IBC

UH50GR-IBC

UD5033

UD5033

UH50

UH50

UH50

UH50

UD5033

UD5033

UH50

UH50

UH50

UH50

8' STAIR TREAD ASSEMBLY

(USSL80-IBC, USSR80-IBC, UST40T-IBC,

UST40-IBC, 08141, 08142), TYP.

5' STAIR TREAD ASSEMBLY

(USSL50-IBC, USSR50-IBC, UST40T-IBC,

UST40-IBC, 05141, 05142), TYP.

(2) US99,

(1) US33

LEG, TYP.

USJ20,

TYP.

0.1

1

TYP.

SEAL:

DE

SC

RIP

TIO

N:

DA

TE

:

RE

VIS

ION

S:

CL

IEN

T:

PR

OJE

CT

:

SH

EE

T T

ITL

E:

PROJECT #:

DRAWN BY:

CHECKED BY:

DATE:

SHEET:

SCALE:

©2

01

7 C

RIM

SO

N E

NG

INE

ER

ING

AS

SO

CIA

TE

S,

INC

. (C

EA

) |

DO

CU

ME

NT

RE

US

E:

TH

IS D

OC

UM

EN

T,

AN

D T

HE

ID

EA

S A

ND

DE

SIG

NS

IN

CO

RP

OR

AT

ED

HE

RE

IN,

AS

AN

IN

ST

RU

ME

NT

OF

PR

OF

ES

SIO

NA

L S

ER

VIC

E,

IS T

HE

PR

OP

ER

TY

OF

CE

A A

ND

IS

NO

T T

O B

E U

SE

D,

IN W

HO

LE O

R I

N P

AR

T,

FO

R A

NY

OT

HE

R P

RO

JEC

T W

ITH

OU

T T

HE

WR

ITT

EN

AU

TH

OR

IZA

TIO

N O

F C

EA

.

E

Crimson Engineering

Associates, Inc.

Denver, Colorado

P: 720.502.4667 | F: 303.974.1734

www.CrimsonEngineering.com

0 1"

PE

DE

ST

RIA

N S

TA

IR T

OW

ER

PO

RT

LAN

D I

NT

ER

NA

TIO

NA

L

AIR

PO

RT

SE

CT

ION

S

195102

KAD

SB

12/22/2019

2.0

SD

B C

ON

TR

AC

TIN

G S

ER

VIC

ES

81

25

NE

CH

ER

RY

DR

.

HIL

LSB

OR

O,

OR

97

12

4

SCALE: 1/4" = 1'-0"

SECTION VIEWC

SCALE: 1/4" = 1'-0"

SECTION VIEWA

A8

/13

/20

19

FO

R R

EV

IEW

B8

/15

/20

19

ISS

UE

D F

OR

CO

NS

TR

UC

TIO

N

C1

2/2

2/1

9P

LAN

CH

EC

K

SCALE: 1/4" = 1'-0"

SECTION VIEWB

SCALE: 1/4" = 1'-0"

SECTION VIEWF

SCALE: 1/4" = 1'-0"

SECTION VIEWE

SCALE: 1/4" = 1'-0"

SECTION VIEWD

UH50

UD

50

12/23/2019

Page 5: GENERAL SCAFFOLD NOTES: LOCATION MAP

SEAL:

DE

SC

RIP

TIO

N:

DA

TE

:

RE

VIS

ION

S:

CL

IEN

T:

PR

OJE

CT

:

SH

EE

T T

ITL

E:

PROJECT #:

DRAWN BY:

CHECKED BY:

DATE:

SHEET:

SCALE:

©2

01

7 C

RIM

SO

N E

NG

INE

ER

ING

AS

SO

CIA

TE

S,

INC

. (C

EA

) |

DO

CU

ME

NT

RE

US

E:

TH

IS D

OC

UM

EN

T,

AN

D T

HE

ID

EA

S A

ND

DE

SIG

NS

IN

CO

RP

OR

AT

ED

HE

RE

IN,

AS

AN

IN

ST

RU

ME

NT

OF

PR

OF

ES

SIO

NA

L S

ER

VIC

E,

IS T

HE

PR

OP

ER

TY

OF

CE

A A

ND

IS

NO

T T

O B

E U

SE

D,

IN W

HO

LE O

R I

N P

AR

T,

FO

R A

NY

OT

HE

R P

RO

JEC

T W

ITH

OU

T T

HE

WR

ITT

EN

AU

TH

OR

IZA

TIO

N O

F C

EA

.

E

Crimson Engineering

Associates, Inc.

Denver, Colorado

P: 720.502.4667 | F: 303.974.1734

www.CrimsonEngineering.com

0 1"

PE

DE

ST

RIA

N S

TA

IR T

OW

ER

PO

RT

LAN

D I

NT

ER

NA

TIO

NA

L

AIR

PO

RT

HA

ND

RA

IL E

ND

CO

NN

EC

TO

RS

195102

JMP

JMP

12/22/2019

3.0

SD

B C

ON

TR

AC

TIN

G S

ER

VIC

ES

81

25

NE

CH

ER

RY

DR

.

HIL

LSB

OR

O,

OR

97

12

4

C1

2/2

2/1

9P

LAN

CH

EC

K

C

12/23/2019


Recommended