1500 Ground Floor Plan Scale 1:50 T 900 1800 1800 7450 1050 TV 1050 1000 AV M 1050 1200 1050 750 1800 T 8 2300 2700 4650 1500 3200 2300 4400 2750 3950 1200 3200 4050 1000 2850 RADON SUMP HOTPRESS AREA: 1.1 m sq 1000 4650 350 HEAT PUMP UNIT Ground Floor Plan - Area: 65 m sq / unit. (700 Sq.ft) Wardrobe 2000 Wardrobe 1000 1000 3850 MASTER BEDROOM AREA: 14m sq BEDROOM 2 AREA: 7.35m sq LIVING AREA AREA: 13.20m sq KITCHEN / DINING AREA BATHROOM AREA: 6.3m sq AREA: 15m sq 1000 10050 HALL AREA: 5.7m sq 900 1200 450 1650 450 950 1500 750 450 1100 1500 T 900 1800 1800 7450 1050 TV 1050 AV M 1050 1200 1050 750 1800 T 8 2300 2700 4650 1500 3200 2300 4400 2750 3950 1200 3200 4050 1000 2850 RADON SUMP HOTPRESS AREA: 1.1 m sq 4650 350 HEAT PUMP UNIT Wardrobe 2000 Wardrobe 1000 1000 3850 MASTER BEDROOM AREA: 14m sq BEDROOM 2 AREA: 7.35m sq LIVING AREA AREA: 13.20m sq KITCHEN / DINING AREA BATHROOM AREA: 6.3m sq AREA: 15m sq 1000 10050 HALL AREA: 5.7m sq 900 450 1650 450 950 1500 750 450 1100 900 SOUTH ELEVATION Scale 1:100 NORTH ELEVATION ESB METER BOX. TELECO/PHONE CABLE DRAW BOX. M AV. CONCRETE TILE ROOF. WHITE ALUMINIUM FASCIA AND SOFFIT. BLACK ALUMINIUM GUTTERS AND MATCHING PVC DOWNPIPES. EXTERNAL RENDER SYSTEM ON EXTERNAL INSULATION. AIR TO AIR HEAT PUMP CONDENSING UNIT MOUNTED ON WALL COMPLETE WITH DRAIN TO GULLY. PLASTERED PLINTH. Scale 1:100 ESB METER BOX. TELECO/PHONE CABLE DRAW BOX. M AV. CISTERN TO BE FULLY INSULATED. PROVIDE SUPPORT FOR WATER STORAGE TANK IN ACCORDANCE WITH HOMEBOND RECOMMENDATION. TIMBER ACCESS WALKWAY FROM HATCH TO TANK CROSS SECTION A-A Scale 1:50 MASTER BEDROOM AREA: 14m sq BEDROOM 2 AREA: 7.37.0m sq 350MM THERMOHOUSE ICF PERIMETER WALLS OR SIMILAR APPROVED.150MM EPS INSULATION OUTER LEAF,150MM 25N10 PLUS STEEL REINFORCEMENT @2KG/M2 CORE AND 50MM EPS INSULATION INNER LEAF. 15MM PLASTERBOARD AND SKIM FINISH INTERNALLY WITH EXTERNAL RENDER SYSTEM TO CONSIST OF A HIGH POLYMER BASE COAT (MIN 10MM), REINFORCING MESH, SILICONE PRIMER AND SILICONE RENDER OR SIMILAR APPROVED FINISH. FOUNDATIONS FOR EXTERNAL WALLS TO BE 1200mm (min.) X 300mm (min.) COMPLETE WITH A393 MESH TO BOTTOM. FOUNDATIONS TO BE MADE ON UNDISTURBED GROUND AND ANY SOFT SPOTS TO BE REMOVED AND MADE GOOD WITH A LEAN MIX CONCRETE TO ENGINEERS APPROVAL.ALL CONCRETE FOR FOUNDATIONS TO 30N20 IN ACCORDANCE WITH BS8110.MIN COVER TO A393 MESH TO BE 50MM. SOFFIT VENTILATION. SELECTED CONCRETE ROOF TILES ON 44mm X 35mm TREATED BATTENS ON TYVEC BREATHER MEMBRANE OEA ON 50mm X 50mm TREATED VERTICAL BATTENS FIXED TO 250MM THICK THERMOHOUSE (OR SIMILAR APPROVED) INSULATED ROOF PLANK.ALL ROOF TIMBERS TO BE PRESSURE TREATED INCL. FASCIA, SOFFIT, BARGE AND GABLE LADDER TIMBERS.INCLUDE FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTING FILLETS, RIDGE BOARDS ETC.PROVIDE ADEQUATE BRACING TO ROOF. TIMBER CEILING JOIST TO STRUCTURAL ENGINEERS SPECIFICATIONS. 2510 STEEL BEAM TO SUPPORT ROOF TO STRUCTURAL ENGINEERS SPECIFICATIONS. TIMBER STUD WALLS. 32° 150MM (MIN) 35N10 POWERFLOATED CONCRETE SLAB COMPLETE WITH A142 MESH.ALL CONCRETE TO BE 35N10 IN ACCORDANCE WITH BS8110.MIN COVER TO A393 MESH TO BE 50MM ON KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR APPROVED), WITH VERTICAL STRIP OF 30MM KOOLTHERM K3 (OR SIMILAR APPROVED) TO PERIMETER OF SLAB ON COMBINED RADON/DPM BARRIER 1200 GAUGE LAID TO MANUFACTURERS SPECIFICATION. RADON BARRIER TO BE LAPPED AT LEAST 150MM & SEALED AT ALL JOINTS AND AT D.P.C.ANY PUNCTURES IN BARRIER SHOULD BE PATCHED WITH THE SAME TYPE OF MEMBRANE, LAPPED AT LEAST 150MM & SEALED BEYOND THE LIMITS OF THE PUNCTURE. PV PANEL ARRAY. 2230 750 2100 1000 2100 2100 5120 PV PANEL ARRAY. EAST ELEVATION Scale 1:100 EXPANSION JOINT. CONCRETE TILE ROOF. 12. WALL & CEILING FINISHES · 12mm FOIL BACKED PLASTERBOARD TO CEILINGS AND INTERNAL WALLS WITH SKIM FINISH · MOISTURE RESISTANT PLASTERBOARD TO BE USED IN BATHROOM. · WALLS AND CEILING TO BE PAINTED WITH 3 COATS OF SOFT SHEEN EMULSION (COLOUR TO BE CHOSEN AT A LATER DATE). · 112MM X 20MM BULLNOSED SOFTWOOD SKIRTING THROUGHOUT. · WALL TO BE TILED IN KITCHEN TO UNDERSIDE OF OVERHEAD UNITS, STANDARD 100x100 CERAMIC PILKINGTON OEA. APPROPRIATE ADHESIVE AND GROUT TO BE USED. INCLUDE FOR ALL NECESSARY CUTTINGS AND TRIMS. · FLUSH SOLID DOORS PAINTED WITH UNDERCOAT AND SATIN WOOD PAINT. TIMBERS TO BE PRIMED BEFORE APPLYING UNDERCOAT AND PAINT. · ALL SHOWER AND BATH FITTING TO BE FITTED TO WALL USING CLASSI-SESAL OR E/A FLEXIBLE WATERPROOF UPSTAND. · ONE ROW OF TILING TO BE PROVIDED ABOVE WASH-HAND BASIN IN BATHROOM. WALLS SURROUNDING SHOWER/BATH TO BE TILED TO CEILING. STANDARD 200X200 CERAMIC PILKINGTON OEA. APPROPRIATE ADHESIVE AND GROUT TO BE USED. INCLUDE FOR ALL NECESSARY CUTTINGS AND TRIMS. PRIMER AND BAL TANKING SYSTEM TO BE APPLIED TO WALLS PRIOR TO TILING. 13. VENTILATION · MECHANICAL HEAT RECOVERY SYSTEM TO BE INSTALLED. SEE SPECIFICATION UNDER FLOOR PLAN. 14. KITCHEN · FITTED KITCHEN AS PER PLANS. 18mm MDF CARCASS AND FRAME. PVC FOIL WRAPPED DOORS, MAX. WIDTH 500mm. DOUBLE CARCASS ON HINGE SIDE OF DOORS. 30mm FORMICA COUNTER TOP. 180° DEGREE STAINLESS STEEL HINGES. WALL MOUNTED OVERHEAD CUPBOARDS · STAINLESS STEEL SINK, 2 TAPS OR DECK MIXER ACCEPTABLE. · FIT INTEGRATED COOKER HOOD, WITH 150mm DUCTING PIPE TO VENT. EXTRACTION RATE TO BE 150m³/H (ASSUMING 6 AIR CHANGES PER HOUR). · DECK MIXER TAPS TO BE INSTALLED AT KITCHEN SINK UNIT. 15. TRAP DOOR · FORM TRAP DOOR IN CEILING IN POSITION AS WILL BE POINTED OUT FOR ACCESS TO ROOF INTERIOR. · THE TRAP DOOR SHALL BE ACCOMMODATED WITHIN THE TRUSS SPACING AND SHALL BE 760MM IN DEPTH. · THE TRAP DOOR SHALL BE CONSTRUCTED WITH 75 X 22MM STOP FILLET AND 12MM THICK CHIPBOARD COVER WITH FIRE BARRIER ON THE BACK [1/2 HOUR FIRE RATING IS REQUIRED AS PER PART B OF THE BUILDING REGULATIONS] AND FINISHED WITH EX 75 X 19MM ARCHITRAVE. · WOODWORK TO BE PAINTED. 16. RADON · RADON SUMP/COLLECTOR TO BE PROVIDED WITH 100mm DIA PVC PIPE WHICH IS TO TERMINATE OUTSIDE EXTERNAL WALL WITH BEND, CAPPED FLUSH WITH PATH. PIPE CAN BE EXTENDED AND FAN FITTED SHOULD SUBSEQUENT READINGS REQUIRE IT. · 100mm MIN. TO BE LEFT EVERY 4TH BLOCK IN COURSE BELOW RADON BARRIER TO PROVIDE AIRFLOW TO RADON SUMP. · PROVIDE REINFORCED RADON BARRIER WITH TEAR RESISTANCE > OR = 100N WITH VAPOUR TRANSMISSION OF < OR = 0.4/M2/24 HOURS WITH ELONGATION (AT MAX. LOAD) OR, > OR =12 WHEN TESTED IN ACCORDANCE WITH 10S 1421. · OR, > OR =12 WHEN TESTED IN ACCORDANCE WITH 10S 1421. 17. PLUMBING & HEATING ALL IN ONE" COMBI SYSTEM WHICH OFFERS MECHANICAL HEAT RECOVERY VENTILATION SYSTEM, AIR SPACE HEATING, DOMESTIC HOT WATER AND COOLING(WHERE REQUIRED) IN ONE INDOOR UNIT TO BE INSTALLED. SEE SPECIFICATION UNDER FLOOR PLAN. ALL PRIMARY PIPEWORK TO BE INSULATED AS DETAILED IN TABLE 11 OF THE DOEHLG “HEATING AND DOMESTIC HOT WATER SYSTEMS FOR DWELLINGS - ACHIEVING COMPLIANCE WITH PART L 2008”. ALL PIPES IN ATTIC TO BE LAGGED WITH 19mm ARMAFLEX INSULATION. ALL PIPES, VALVES AND SWITCHES TO BE VISIBLE AND CLEARLY LABELED. · INCLUDE FOR SUPPLY AND INSTILLATION OF ALL NEW SANITARY WARE. TOILETS,SEATS,SINKS,TAPS, SHOWER DOORS, BATH,TOILET ROLL HOLDERS TO COMPLETE ALL BATHROOMS IN FULL. ALL TO BE ARMITAGE SHANK. WHITE ARMITAGE SHANKS 'SANDRINGHAM CLASSIC O.E.A SANITARY WARE TO BE INSTALLED. LEVER TAPS TO BE INSTALLED. · `EASA` "THE ACCESS TRAY" 1000MM X 1000MM MIN LEVEL ACCESS SHOWER TRAY, WITH CLASSY SEAL WHERE TRAY MEETS WALL, GRADIENT TO DRAINAGE DOES NOT EXCEED 1:40 SLOPE. NEW SHOWER UNIT, WHICH IS TO BE A THERMOSTATICALLY CONTROLLED SHOWER WITH A SAFE ANTI-SCALD TEMPERATURE OF 41 DEGREES.(OFF TANK, NOT MAINS) A 2M FLEXIBLE HOSE IS TO BE PROVIDED. · WEIGHTED SHOWER CURTAINS & HALF HEIGHT EASA EVOLUTION PORTABLE DOORS WITH CHROME FINISH AND POLYCARBONATE DOORS. FLOOR TO BE TILED WITH NON-SLIP TILES. WHB TO BE BRACKETED, NO PEDESTAL. WASTE PIPES TO BE RECESSED. LEVER TAPS. · 350 LITRE CAPACITY IN ROOF SPACE. PROVIDE EXPANSION TANK OF APPROXIMATELY 45 LITRE CAPACITY. EACH TANK SHOULD BE PROVIDED WITH APPROPRIATE COVER AND SUPPORTED IN ACCORDANCE WITH GUIDELINES AS SET OUT IN THE BUILDING REGULATIONS. WALKWAY TO BE LAID IN ATTIC FROM TRAP DOOR TO WATER TANK. LIGHT TO BE FITTED IN ATTIC. · ALL SANITARY FITTING AND APPLIANCES TO HAVE FLEXIBLE PENNYVALVE FEEDS. · FIT 'COMBIMATE' WATER SOFTENER TO ALL HOUSES. · FIT 'MAGNACLEAN PROFESSIONAL' FILTER SYSTEM. · GULLY TO BE INSTALLED UNDERNEATH HEAT PUMP SYSTEM TO COLLECT WATER EXTRACT FROM SYSTEM. GULLY TO BE LINKED TO FOUL WATER DRAINAGE SYSTEM. PVC DROP TO BE INSTALLED FROM UNIT TO GULLY UNDERNEATH TO ALLOW FOR CONDENSATION RUNOFF · 50mm (min) DRAIN ADJACENT TO THE WATER TANK UNIT OF THE HEAT PUMP - PLUMPED TO THE OUTSIDE TO ALLOW FOR OVERFLOW. 18. ELECTRICAL · BATHROOM & EXTERNAL LIGHTS TO HAVE LED 12 WATT COOL WHITE BULBS FITTED. · ALL SMOKE/HEAT DETECTORS TO BE LINKED. · ALL ELECTRICAL WORK TO BE TO CURRENT RECI STANDARDS · NO WALL SOCKETS ARE TO BE BACK TO BACK ON PARTY WALL · ALL SMOKE / HEAT / C02 DETECTORS TO BE WIRED BACK TO INDICATOR PANEL UNIT, LOCATED BESIDE FUSE BOARD · SHOWER INSTALLATIONS TO HAVE ESB CABLE TAILS FROM METER TO BOARD TO BE 16 SQUARE, AND CABLE FROM BOARD TO SHOWER MUST BE 10 SQUARE. BATHROOM LIGHT TO BE ON AN RCD. 19. AIR TIGHTNESS TEST CONTRACTOR IS TO INCLUDE FOR CARRYING OUT AN AIR TIGHTNESS TEST. 20. BUILDING ENERGY RATING (BER) CERTIFICATE CONTRACTOR IS TO PROVIDE BER CERTIFICATE ON COMPLETION OF CONSTRUCTION - MINIMUM ACCEPTABLE BER RATING IS A2 GENERAL SPECIFICATION 1. FOUNDATIONS · CONCRETE STRIP FOUNDATIONS TO ENGINEERS DETAILS AND SUBJECT TO SITE CONDITIONS. · FOUNDATIONS FOR EXTERNAL WALLS TO BE 1200mm (min.) X 300mm (min.) WITH A393 MESH BOTTOM. FOUNDATIONS FOR INTERNAL WALLS TO 1000mm (min.) X 300mm (min.) WITH A393 MESH BOTTOM. · FOUNDATIONS TO BE MADE ON UNDISTURBED GROUND AND ANY SOFT SPOTS TO BE REMOVED AND MADE GOOD WITH A LEAN MIX CONCRETE TO ENGINEERS APPROVAL. · ALL CONCRETE FOR FOUNDATIONS TO 30N20 IN ACCORDANCE WITH BS8110. · MIN COVER TO A393 MESH TO BE 50MM 2. RISING WALLS · RISING WALL CONSTRUCTION TO BE 150MM EPS INSULATION OUTER LEAF,150MM 25N10 PLUS STEEL REINFORCEMENT @2KG/M2 CORE AND 50MM EPS INSULATION INNER LEAF. · 50mm CLEARANCE TO SURROUND SERVICE PIPES. FOR LARGE OPENINGS A LINTEL (NOT METAL) SHOULD BE PROVIDED. 3. FLOORS · 150MM 35N10 POWERFLOATED CONCRETE FLOOR WITH A142 MESH. · KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR APPROVED), WITH VERTICAL STRIP OF 30MM KOOLTHERM K3 (OR SIMILAR APPROVED) TO PERIMETER OF SLAB. · COMBINED RADON/DPM BARRIER 1200 GAUGE LAID TO MANUFACTURERS SPECIFICATION. RADON BARRIER TO BE LAPPED AT LEAST 150MM AND SEALED AT ALL JOINTS AND AT D.P.C. ANY PUNCTURES IN BARRIER SHOULD BE PATCHED WITH THE SAME TYPE OF MEMBRANE, LAPPED AT LEAST 150MM AND SEALED BEYOND THE LIMITS OF THE PUNCTURE. · 50MM SAND BLINDING. · 225MM COMPACTED CLAUSE 804 STONE COMPLIANT WITH S.R 21-2014 ANNEX E ON 400MM OF 75MM DIA CLEAN BROKEN STONE COMPLIANT WITH SR.21-2014 ANNEX E. · KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR APPROVED), WITH VERTICAL STRIP OF 30MM KOOLTHERM K3 (OR SIMILAR APPROVED) TO PERIMETER OF SLAB. 4. WALLS · 0.015W/M2K MAX. ICF (INSULATING CONCRETE FORMWORK) SYSTEM, WHICH CONSISTS OF MODULAR INTERLOCKING EXPANDED POLYSTYRENE (EPS) BUILDING BLOCKS (STANDARD WHITE AND GREY) FOR PERMANENT FORMWORK FOR THE CONSTRUCTION OF IN-SITU CONCRETE WALLS. THE EXTERNAL WALLS, PARTY WALLS, FLOOR AND ROOF ARE TO BE CONSTRUCTED IN THIS MANNER. THE GGBS RATIO OF ECO-FRIENDLY CEMENT USED IN THE POUR MUST BE MINIMUM 70%. EACH OF THE BLOCKS IS LINKED TOGETHER WITH STEEL TIES FOR STRENGTH. THE UNITS ARE TO BE ERECTED AS FORMWORK INTO WHICH VERTICAL AND HORIZONTAL REINFORCEMENT IS PLACED AND THEN FILLED WITH CONCRETE AND VIBRATED TO CREATE A MONOLITHIC CONCRETE WALL. THE POURED WALL THEN RETAINS THE FORMWORK INSULATION FOR THE LIFE OF THE BUILDING. A LOW MAINTENANCE AND DURABLE EXTERNAL RENDER SYSTEM APPROVED BY NSAI AGRÉMENT FOR USE WITH ICF SYSTEMS IS TO BE APPLIED TO THE EXTERNAL POLYSTYRENE INSULATION OF THE ICF SYSTEM AS THE EXTERNAL FINISH. INTERNALLY, THE PLASTERBOARD IS FIXED DIRECTLY THROUGH THE EPS INTO THE CONCRETE CORE WITH PLASTIC INSULATED ANCHORS, OR ALTERNATIVELY SCREWED TO TIMBER BATTENS. · ALL OPENINGS/HEADS/JAMBS ETC IN ACCORDANCE WITH MANUFACTURERS DETAILS. · CONCRETE CILLS ON PVC DPC TURNED UP AT BACK AND SIDES. · RENDER SYSTEM TO CONSIT OF A HIGH POLYMER BASE COAT (MIN 10MM), REINFORCING MESH, SILICONE PRIMER AND SILICONE RENDER OR SIMILAR APPROVED FINISH. 5. ROOF · MAIN STRUCTURE. U VALUE MAX. 0.15W/M2K MAX. 250MM THICK INTERLOCKING EXPANDED POLYSTYRENE (EPS) PANELS COMPLETE WITH INTEGRATED STEEL C-SECTINS. NAIL EVERY SECOND ROW OF ROOF TILES, AND ALL PERIMETER TILES. · SELECTED CONCRETE ROOF TILES ON 44MM X 35MM TREATED BATTENS ON TYVEC BREATHER MEMBRANE OEA ON 50MM X 50MM TREATED VERTICAL BATTENS FIXED TO 250MM THICK THERMOHOUSE (OR SIMILAR APPROVED) INSULATED ROOF PANEL. ANY ROOF TIMBERS TO BE PRESSURE TREATED INCL. FASCIA, SOFFIT, BARGE AND GABLE LADDER TIMBERS.INCLUDE FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTING FILLETS, RIDGE BOARDS ETC.PROVIDE ADEQUATE BRACING TO ROOF. · INCLUDE FOR ALL STEEL MEMBERS AND BEARING PADS TO SUPPORT ROOF STRUCTURE. · INCLUDE FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTING FILLETS, RIDGE BOARDS ETC. · CONNECT ROOF STRUCTURE TO WALL PLATES USING PROPRIETARY TRUSS CLIPS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. · EAVE VENTILATORS TO BE FITTED. ROOF VENT TILE TO BE FITTED AT RIDGE LEVEL AS PER MANUFACTURES SPEC & DETAILS · PATINATION OIL FINISH TO ALL CODE 5 LEAD, TO MANUFACTURES SPECIFICATION AND DETAIL. · DRY VERGE SYSTEM. EASY TRIM VERGE U COMPLETE WITH RIDGE CAPS, STARTER CAPS AND END CAPS. 6. FASCIA, SOFFIT AND DOWNPIPES · ALUMINIUM FASCIA AND SOFFIT, 10MM CONTINUOUS VENT GAP BETWEEN FASCIA AND SOFFIT (250MM OVERHANG). · 125MM SEAMLESS ALUMINIUM GUTTERS WITH 75MM X 50MM PVC DOWN PIPES. 7. INTERNAL DOORS · DOOR FRAMES TO BE DEAL. · FINISH SIZE TO BE EX 150MM X 50MM REBATED WITH 75MM X 20MM SPLAYED ARCHITRAVES STANDARD TO FLUSH DOORS. · SOLID PLY VENEER FLUSH DOORS THROUGHOUT · LOCKS AND HANDLES TO BE BRASS SONNATO BW450PB. · 3 STEEL BUTT HINGES PER DOOR · 22MM WHITE/RED DEAL SADDLE BOARDS, VARNISHED. · DOOR STOPS TO BE FITTED TO ALL DOORS 8. D.P.C. · DPC CAVITY TRAY OVER ALL OPES · DPC TO BE USED UNDER WALL PLATE · DPC OVER OPES 160MM X 65MM EXTERNAL 9. OPES · ROW OF MASONARY MESH REINFORCEMENT FOR FULL LENGTH OF FRONT & BACK WALL ABOVE LINTELS 10. WINDOWS & DOORS · PVC WINDOW FRAMES. EXTERNAL GLAZING THROUGHOUT TO BE OF A PROPRIETARY TRIPLE GLAZED SUPERIOR QUALITY THERMALLY BROKEN GLAZING SYSTEM DESIGNED, BUILT AND INSTALLED TO LATEST RELEVANT EUROPEAN STANDARDS, CODES OF PRACTICE, AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. MAXIMUM WHOLE FRAME U VALUE OF :0ð. AND A G-FACTOR OF 50% WILL BE REQUIRED FOR ALL WINDOWS AND EXTERNAL DOORS. ALL GLAZING MUST BE INTERNALLY BEADED/SECURED. EXTERNAL DOORS MUST BE IMPACT RESISTANT TIMBER HALL DOORS TO EN 1627, WITH LEVEL ACCESS THRESHOLD, & 3-POINT LOCKING SYSTEM. A MANUFACTURER'S THERMAL PERFORMANCE CERTIFICATE WILL BE REQUIRED FOR EACH WINDOW TYPE IN EACH HOUSE TYPE THROUGHOUT THE DEVELOPMENT FOR INCLUSION WITH THE BCAR INFORMATION AND CERTIFICATION PROCESS. · COMPOSITE FRONT DOOR AND THERMALLY BROKEN ALUMINUM BACK DOOR. · SAMPLE OF DOOR & WINDOW TO BE PROVIDED PRIOR TO ORDERING. · ALL BEDROOM WINDOWS TO HAVE MIN. OPE OF 850X500MM, ( IN COMPLIANCE WITH CURRENT BUILDING REGS) TO ALLOW ADEQUATE MEANS OF ESCAPE. CHILD SAFETY RESTRICTORS TO BE FITTED TO BEDROOM WINDOWS.NON LOCKABLE HANDLES TO BE FITTED. 11. THERMAL BRIDGING · ALL INTERNAL PLASTERBOARD/PLASTER FINISHES TO GO DOWN TO FLOOR LEVEL. · ALL ELECTRICAL CONDUIT IN ATTIC SPACE TO BE SEALED. · AFTER FITTING OF WINDOWS & DOORS ALL GAPS TO BE SEALED BEFORE PLASTERING · ATTIC HATCH TRAP DOOR TO BE FITTED WITH LATCH AND DRAFT EXCLUDER STRIPS. · ALL PIPE AND SERVICE PENETRATIONS OF BUILDING ENVELOPE TO BE SEALED · THERMAL BRIDGING & ABC DETAILS TO COMPLY WITH 2007 BUILDING REGULATIONS. REFER TO THE DOCUMENT ' LIMITING AIR INFILTRATION - ACCEPTABLE CONSTRUCTION DETAILS' · GLAZING TO BATHROOM TO BE OBSCURED · PRECAST CONCRETE CILLS THROUGHOUT WITH DPC TO SIDES, BACK & UNDERNEATH TO BE USED THROUGHOUT. · 19MM BULLNOSE WHITE DEAL WINDOW BOARDS, PAINTED. · WINDOW BOARDS IN KITCHEN AND BATHROOM TO BE TILED. · DOORS & WINDOWS TO INCLUDE ALL NECESSARY IRONMONGERY. RECEIVER TYPE ON EXTERNAL DOORS TO BE OF THE HOOKED TYPE. 5 POINT LOCKING SYSTEM. · FRONT DOOR TO HAVE THRESHOLD HEIGHT OF 15mm, WITH EXPOSED EDGES CHAMFERED. TV KEY TO ELECTRICAL SYMBOLS T 8 T NOTE 1: INCLUDE FOR ALL NECESSARY BUILDERS WORK AND ATTENDANCES FOR MECH. & ELEC. INSTALLATIONS. ALL CHASINGS TO BE MACHINE CUT. APPROVED SPECILIST CONTRCACTOR LOCATIONS OF FIRE STOPPING - WORKS BY SERVICES LEGEND FOUL WATER AJ AND PIPEWORK SURFACE WATER AJ AND PIPEWORK SOIL VENT PIPE nZED Compliant Specification: · Space Heating / Cooling Demand Not to exceed 15kWh annually or 10W (Peak Demand) per m² · Air Infiltration : AIr Tightness: Acceptable range of 0.6 - 1 air changes/hour @50 Pascals · U-Values: Floor: U-Value: 0.012W/m2k. 150mm thick insulation with a thermal conductivity of 0.022W/mk. 30mm insulation strip to all edges of floor. Walls: U-Value: 0.015W/m2k Max. ICF (Insulating Concrete Formwork) System, which consists of modular interlocking expanded polystyrene (EPS) building blocks (standard white and grey) for permanent formwork for the construction of in-situ concrete walls. The external walls, party walls, floor and roof are to be constructed in this manner. The GGBS ratio of eco-friendly cement used in the pour must be minimum 70%. Each of the blocks is linked together with steel ties for strength. The units are to be erected as formwork into which vertical and horizontal reinforcement is placed and then filled with concrete and vibrated to create a monolithic concrete wall. The poured wall then retains the formwork insulation for the life of the building. A low maintenance and durable external render system approved by NSAI Agrément for use with ICF systems is to be applied to the external polystyrene insulation of the ICF system as the external finish. Internally, the plasterboard is fixed directly through the EPS into the concrete core with plastic insulated anchors, or alternatively screwed to timber battens. Roof: U-Value: 0.15W/m2k Max. 250MM thick Interlocking expanded polystyrene (EPS) panels complete with integrated steel C-Sectins. Windows/ Doors: U-Value: External glazing throughout must be of a proprietary triple glazed superior quality thermally broken glazing system designed, built and installed to latest relevant European standards, Codes of Practice, and installed in accordance with the Manufacturers requirements and recommendations. Maximum whole frame U value of :Pð. and a G-Factor of 50% will be required for all windows and external doors. All glazing must be internally beaded/secured. External doors must be impact resistant timber hall doors to EN 1627, with level access threshold, & 3-point locking system. A Manufacturer's Thermal Performance Certificate will be required for each window type in each house type throughout the development for inclusion with the BCAR information and Certification process. · PV Panels: 2 Bed Semi (single storey): 2kWp Solar Photovoltaic system as per Spec Attached. · Attic Access: Attic access hatch is to be draught stripped · Thermal Bridging: 0.08 x total exposed area (W/m2K) - refer to Appendix D in Part L 2011 Building regulations for details · Air Tightness: All windows and doors are to be sealed with the appropriate air tightness tape and membrane. Specialist Contractor to be appointed as required to carried out work · Heating/Cooling/DHW/Ventilation System: All in One" combi system which offers mechanical heat recovery ventilation system, air space heating, Domestic Hot Water and Cooling(where required) in one indoor unit. The MVHR element is a double stage process made to control the supply air intake temperature up to 34 C via heat recovery and ensures DHW Production through a 180l 5mm polyurethane foam-insulated, 2-layer glass enameled hot water tank w/1.5 kw immersion as backup. The combi system uses energy from exhaust air to first covers ventilation losses with passive heat exchanger, and then it produces DHW and space heating with the integrated Heat Pump. This is achieved using a 500W Compressor, therefore using a small amount of energy. The heat pump has a reversible cooling circuit, which means that, in the summer, the unit can cool the supply air by up to 10 °C. Due to the low air exchange, the cooling does not function as an air conditioning system. On cooling, the supply air is dehumidified, which gives a more pleasant indoor climate than is possible with an ordinary ventilation unit without a heat pump. The combi system mechanical ventilation heat recovery system will supply a large portion of the required heat demand of the respective homes by circulating air which has been fed through a heat exchanger. However, to supplement this system in times of higher heating demand / colder weather, an electric radiant panel system is to be supplied and installed. It is proposed to implement a 3 x 600W Radiant Panel system with 1 panel installed in the Living/Dining Area and 1 panel in each of the bedrooms. RADIANT HEAT BACKUP The combi system mechanical ventilation heat recovery system will supply a large portion of the required heat demand of the respective homes by circulating air which has been fed through a heat exchanger. However, to supplement this system in times of higher heating demand / colder weather, an electric radiant panel system is to be supplied and installed. It is proposed to implement a 3 x 600W Radiant Panel system with 1 panel installed in the Living/Dining Area and 1 panel in each of the bedrooms. Suitable controls should be integrated with the system to ensure it is operated efficiently and effectively. The sizing and quantities of the panels can be finalized based on supplier recommendations but 3 x 600W in a home of such size is a good practice ratio. Consideration must be given to the anticipated high thermal performance of the home and that limited heating will be required. The radiant panels can be wall-mounted, or ceiling mounted depending on the site layout/occupancy. To maximize space, thermal performance, aesthetics and negate safety concerns, it is proposed that the Radiant Panels are ceiling mounted. · Light Fittings: 100% Light bulbs are to be Low Energy Bulbs · Draught Strips to Ext Windows & Doors: All external windows and doors are to arrive to site with their draught stripping intact and installed according to Manufactures specification and details · Ventilation: A Mechanical Ventilation Heat Recovery is to be installed. The MVHR is to provide fresh filtered air into the building whilst retaining most of the energy that has already been used in heating the building. The heat recovery ventilation system is to be properly fitted to provide a constant supply of fresh filtered air, maintaining the air quality whilst being practically imperceptible. The MVHR system is to operate by extracting the air from the polluted sources e.g. kitchen, bathroom, toilets and utility rooms and supplying air to the 'living' rooms e.g. bedrooms, living rooms, studies etc. The extracted air is taken through a central heat exchanger and the heat recovered into the supply air. SPACE PROVISION CALCULATION. DWELLING TYPE: 2 BED/3 PERSON SINGLE STOREY. TARGET GROSS FLOOR AREA (m2) MINIMUM-MAIN LIVING ROOM (m2) AGGREGATE LIVING AREA (m2) AGGREGATE BEDROOM AREA (m2) 60 13 28 20 STORAGE (m2) 3 65 13.2 28.2 21.35 3 PROPOSED GROSS FLOOR AREA (m2) PROPOSED MAIN LIVING ROOM (m2) PROPOSED AGGREGATE LIVING AREA (m2) PROPOSED AGGREGATE BEDROOM AREA (m2) PROPOSED STORAGE (m2) General Specification Max Permitted U-Values Building Envelope Specification Ventilation System Specification. Heating/DHW/Vent/Cooling System Specification. Solar PV Performance Specification WEST ELEVATION Scale 1:100 EXPANSION JOINT. LEVEL AREA OF 1.2M X 1.2M TO BE PROVIDED AT FRONT ENTRANCE. RAMP NO GREATER THAN 1:20 TO ACCESS LEVEL AREA. NAPPED & PAINTED FINISH TO PORCH. 5120 2230 750 2100 750 2100 EXTERNAL RENDER SYSTEM ON EXTERNAL INSULATION. CONCRETE TILE ROOF. DWELLING PLAN ELEVATIONS & SECTION. (2 BED SEMI-DETACHED DWELLING) 1. This drawing is the property of Carlow County Council, it is a confidential document and must not be copied, used, or its content divulged without prior written consent. 2. DO NOT SCALE, use figured dimensions only, if in doubt ask. NOTES As Shown R.S. Project: Title: Drawn by: Checked by: Approved by: Scale: Date: L.S. Rev: No. Date Amendment / Issue Chk. Drn. A Job No: Drw Loc: Drg. No: App. A FOR REVIEW 02/05/2019 RS. 12/02/2020 LS L.S. CARLOW COUNTY COUNCIL HOUSING DEPARTMENT Director Of Services: Michael Brennan Tullow Civic Offices, Inner Relief Road, Tullow, Co. Carlow Phone: (059)9136296 Fax: (059)9152156 Email: [email protected] Carlow Local Authorities, A CPD Accredited Company Includes Ordnance Survey Ireland data reproduced under Osi Licence Number 2010/21 CCMA Carlow County Council. Unauthorised reproduction infringes Ordnance Survey Ireland and Government of Ireland Copyright Ordnance Survey Ireland 2015 L.S. DWELLING PLAN, ELEVATIONS & SECTION. i-107 CONSTRUCTION OF 4 No. HOUSES AT ST MARYS COURT, CO. CARLOW. FOR REVIEW ON 12.02.2020
Transcript
Page 1: GENERAL SPECIFICATION NOTES 1. FOUNDATIONS 12.WALL ...

1500

Ground Floor Plan Scale 1:50

T

9001800

1800

74

50

1050

TV

1050

10

00

AV

M

1050 1200 1050 750

1800

T

8

2300

27

00

4650 1500 3200

23

00

44

00

27

50

39

50

1200

3200

40

50

1000

28

50

RADON

SUMP

HOTPRESSAREA: 1.1 m sq

10

00

4650

350

HEAT PUMP

UNIT

Ground Floor Plan - Area: 65 m sq / unit. (700 Sq.ft)

Wardrobe2000

Wardrobe

1000

10

00

3850

MASTER BEDROOMAREA: 14m sq

BEDROOM 2AREA: 7.35m sq

LIVING AREAAREA: 13.20m sq

KITCHEN / DINING AREA

BATHROOMAREA: 6.3m sq

AREA: 15m sq

1000

10050

HALLAREA: 5.7m sq

900 1200

45

0

16

50

450

950

1500

750

450

11

00

1500

T

9001800

1800

74

50

1050

TV

1050

AV

M

105012001050750

1800

T

8

2300

27

00

465015003200

23

00

44

00

27

50

39

50

1200

3200

40

50

1000

28

50

RADON

SUMP

HOTPRESSAREA: 1.1 m sq

4650

350

HEAT PUMP

UNIT

Wardrobe2000

Wardrobe

1000

10

00

3850

MASTER BEDROOMAREA: 14m sq

BEDROOM 2AREA: 7.35m sq

LIVING AREAAREA: 13.20m sq

KITCHEN / DINING AREA

BATHROOMAREA: 6.3m sq

AREA: 15m sq

1000

10050

HALLAREA: 5.7m sq

900

45

0

16

50

450

950

1500

750

450

11

00

900

SOUTH ELEVATION Scale 1:100 NORTH ELEVATION

ESB METER BOX.

TELECO/PHONE CABLE DRAW BOX.

M

AV.

CONCRETE TILE ROOF.

WHITE ALUMINIUM FASCIA AND SOFFIT.

BLACK ALUMINIUM GUTTERS

AND MATCHING

PVC DOWNPIPES.

EXTERNAL RENDER SYSTEM

ON EXTERNAL INSULATION.

AIR TO AIR HEAT PUMP CONDENSING

UNIT MOUNTED ON WALL COMPLETE

WITH DRAIN TO GULLY.

PLASTERED PLINTH.

Scale 1:100

ESB METER BOX.

TELECO/PHONE CABLE DRAW BOX.

M

AV.

CISTERN TO BE FULLY INSULATED. PROVIDE SUPPORT FOR

WATER STORAGE TANK IN ACCORDANCE WITH HOMEBOND

RECOMMENDATION.

TIMBER ACCESS WALKWAY FROM HATCH TO TANK

CROSS SECTION A-A Scale 1:50

MASTER BEDROOM AREA: 14m sq

BEDROOM 2AREA: 7.37.0m sq

350MM THERMOHOUSE ICF PERIMETER WALLS OR SIMILAR

APPROVED.150MM EPS INSULATION OUTER LEAF,150MM 25N10

PLUS STEEL REINFORCEMENT @2KG/M2 CORE AND 50MM EPS

INSULATION INNER LEAF. 15MM PLASTERBOARD AND SKIM

FINISH INTERNALLY WITH EXTERNAL RENDER SYSTEM TO

CONSIST OF A HIGH POLYMER BASE COAT (MIN 10MM),

REINFORCING MESH, SILICONE PRIMER AND SILICONE RENDER

OR SIMILAR APPROVED FINISH.

FOUNDATIONS FOR EXTERNAL WALLS TO BE 1200mm (min.) X 300mm (min.) COMPLETE WITH A393 MESH TO BOTTOM.

FOUNDATIONS TO BE MADE ON UNDISTURBED GROUND AND ANY SOFT SPOTS TO BE REMOVED AND MADE GOOD WITH A

LEAN MIX CONCRETE TO ENGINEERS APPROVAL.ALL CONCRETE FOR FOUNDATIONS TO 30N20 IN ACCORDANCE WITH

BS8110.MIN COVER TO A393 MESH TO BE 50MM.

SOFFIT

VENTILATION.

SELECTED CONCRETE ROOF TILES ON 44mm X 35mm TREATED

BATTENS ON TYVEC BREATHER MEMBRANE OEA ON 50mm X

50mm TREATED VERTICAL BATTENS FIXED TO 250MM THICK

THERMOHOUSE (OR SIMILAR APPROVED) INSULATED ROOF

PLANK.ALL ROOF TIMBERS TO BE PRESSURE TREATED INCL.

FASCIA, SOFFIT, BARGE AND GABLE LADDER TIMBERS.INCLUDE

FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTING FILLETS,

RIDGE BOARDS ETC.PROVIDE ADEQUATE BRACING TO ROOF.

TIMBER CEILING JOIST TO

STRUCTURAL ENGINEERS

SPECIFICATIONS.

25

10

STEEL BEAM TO SUPPORT

ROOF TO STRUCTURAL

ENGINEERS SPECIFICATIONS.

TIMBER STUD WALLS.

3

2

°

150MM (MIN) 35N10 POWERFLOATED CONCRETE SLAB

COMPLETE WITH A142 MESH.ALL CONCRETE TO BE 35N10 IN

ACCORDANCE WITH BS8110.MIN COVER TO A393 MESH TO BE

50MM ON KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR

APPROVED), WITH VERTICAL STRIP OF 30MM KOOLTHERM K3 (OR

SIMILAR APPROVED) TO PERIMETER OF SLAB ON COMBINED

RADON/DPM BARRIER 1200 GAUGE LAID TO MANUFACTURERS

SPECIFICATION. RADON BARRIER TO BE LAPPED AT LEAST

150MM & SEALED AT ALL JOINTS AND AT D.P.C.ANY PUNCTURES

IN BARRIER SHOULD BE PATCHED WITH THE SAME TYPE OF

MEMBRANE, LAPPED AT LEAST 150MM & SEALED BEYOND THE

LIMITS OF THE PUNCTURE.

PV PANEL ARRAY.

2230

750

2100

1000

2100

2100

5120

PV PANEL ARRAY.

EAST ELEVATION Scale 1:100

EXPANSION JOINT.

CONCRETE TILE ROOF.

12. WALL & CEILING FINISHES· 12mm FOIL BACKED PLASTERBOARD TO CEILINGS AND INTERNAL WALLS WITH SKIM

FINISH· MOISTURE RESISTANT PLASTERBOARD TO BE USED IN BATHROOM.· WALLS AND CEILING TO BE PAINTED WITH 3 COATS OF SOFT SHEEN EMULSION

(COLOUR TO BE CHOSEN AT A LATER DATE).· 112MM X 20MM BULLNOSED SOFTWOOD SKIRTING THROUGHOUT.· WALL TO BE TILED IN KITCHEN TO UNDERSIDE OF OVERHEAD UNITS, STANDARD

100x100 CERAMIC PILKINGTON OEA. APPROPRIATE ADHESIVE AND GROUT TO BEUSED. INCLUDE FOR ALL NECESSARY CUTTINGS AND TRIMS.

· FLUSH SOLID DOORS PAINTED WITH UNDERCOAT AND SATIN WOOD PAINT. TIMBERSTO BE PRIMED BEFORE APPLYING UNDERCOAT AND PAINT.

· ALL SHOWER AND BATH FITTING TO BE FITTED TO WALL USING CLASSI-SESAL OR E/AFLEXIBLE WATERPROOF UPSTAND.

· ONE ROW OF TILING TO BE PROVIDED ABOVE WASH-HAND BASIN IN BATHROOM. WALLS SURROUNDING SHOWER/BATH TO BE TILED TO CEILING. STANDARD 200X200 CERAMIC PILKINGTON OEA. APPROPRIATE

ADHESIVE AND GROUT TO BE USED. INCLUDE FOR ALL NECESSARY CUTTINGS AND TRIMS. PRIMER AND BAL TANKING SYSTEM TO BE APPLIED

TO WALLS PRIOR TO TILING.

13. VENTILATION· MECHANICAL HEAT RECOVERY SYSTEM TO BE INSTALLED. SEE SPECIFICATION

UNDER FLOOR PLAN.

14. KITCHEN· FITTED KITCHEN AS PER PLANS. 18mm MDF CARCASS AND FRAME. PVC FOIL

WRAPPED DOORS, MAX. WIDTH 500mm. DOUBLE CARCASS ON HINGE SIDE OF DOORS.30mm FORMICA COUNTER TOP. 180° DEGREE STAINLESS STEEL HINGES. WALLMOUNTED OVERHEAD CUPBOARDS

· STAINLESS STEEL SINK, 2 TAPS OR DECK MIXER ACCEPTABLE.· FIT INTEGRATED COOKER HOOD, WITH 150mm DUCTING PIPE TO VENT. EXTRACTION

RATE TO BE 150m³/H (ASSUMING 6 AIR CHANGES PER HOUR).· DECK MIXER TAPS TO BE INSTALLED AT KITCHEN SINK UNIT.

15. TRAP DOOR· FORM TRAP DOOR IN CEILING IN POSITION AS WILL BE POINTED OUT FOR ACCESS TO

ROOF INTERIOR.· THE TRAP DOOR SHALL BE ACCOMMODATED WITHIN THE TRUSS SPACING AND SHALL

BE 760MM IN DEPTH.· THE TRAP DOOR SHALL BE CONSTRUCTED WITH 75 X 22MM STOP FILLET AND 12MM

THICK CHIPBOARD COVER WITH FIRE BARRIER ON THE BACK [1/2 HOUR FIRE RATINGIS REQUIRED AS PER PART B OF THE BUILDING REGULATIONS] AND FINISHED WITH EX75 X 19MM ARCHITRAVE.

· WOODWORK TO BE PAINTED.

16. RADON· RADON SUMP/COLLECTOR TO BE PROVIDED WITH 100mm DIA PVC PIPE WHICH IS TO

TERMINATE OUTSIDE EXTERNAL WALL WITH BEND, CAPPED FLUSH WITH PATH. PIPECAN BE EXTENDED AND FAN FITTED SHOULD SUBSEQUENT READINGS REQUIRE IT.

· 100mm MIN. TO BE LEFT EVERY 4TH BLOCK IN COURSE BELOW RADON BARRIER TOPROVIDE AIRFLOW TO RADON SUMP.

· PROVIDE REINFORCED RADON BARRIER WITH TEAR RESISTANCE > OR = 100N WITHVAPOUR TRANSMISSION OF < OR = 0.4/M2/24 HOURS WITH ELONGATION (AT MAX.LOAD) OR, > OR =12 WHEN TESTED IN ACCORDANCE WITH 10S 1421.

· OR, > OR =12 WHEN TESTED IN ACCORDANCE WITH 10S 1421.

17. PLUMBING & HEATINGALL IN ONE" COMBI SYSTEM WHICH OFFERS MECHANICAL HEAT RECOVERY VENTILATION SYSTEM, AIR SPACE HEATING, DOMESTIC HOT WATER AND COOLING(WHERE REQUIRED) IN ONE INDOOR UNIT TO BE INSTALLED. SEE SPECIFICATION UNDER FLOOR PLAN.

ALL PRIMARY PIPEWORK TO BE INSULATED AS DETAILED IN TABLE 11 OF THE DOEHLG “HEATING AND DOMESTIC HOT WATER SYSTEMS FOR DWELLINGS - ACHIEVING COMPLIANCE WITH PART L 2008”.ALL PIPES IN ATTIC TO BE LAGGED WITH 19mm ARMAFLEX INSULATION.ALL PIPES, VALVES AND SWITCHES TO BE VISIBLE AND CLEARLY LABELED.

· INCLUDE FOR SUPPLY AND INSTILLATION OF ALL NEW SANITARY WARE.TOILETS,SEATS,SINKS,TAPS, SHOWER DOORS, BATH,TOILET ROLL HOLDERS TOCOMPLETE ALL BATHROOMS IN FULL. ALL TO BE ARMITAGE SHANK. WHITEARMITAGE SHANKS 'SANDRINGHAM CLASSIC O.E.A SANITARY WARE TO BEINSTALLED. LEVER TAPS TO BE INSTALLED.

· `EASA` "THE ACCESS TRAY" 1000MM X 1000MM MIN LEVEL ACCESS SHOWER TRAY,WITH CLASSY SEAL WHERE TRAY MEETS WALL, GRADIENT TO DRAINAGE DOES NOTEXCEED 1:40 SLOPE. NEW SHOWER UNIT, WHICH IS TO BE A THERMOSTATICALLYCONTROLLED SHOWER WITH A SAFE ANTI-SCALD TEMPERATURE OF 41 DEGREES.(OFFTANK, NOT MAINS) A 2M FLEXIBLE HOSE IS TO BE PROVIDED.

· WEIGHTED SHOWER CURTAINS & HALF HEIGHT EASA EVOLUTION PORTABLE DOORSWITH CHROME FINISH AND POLYCARBONATE DOORS. FLOOR TO BE TILED WITHNON-SLIP TILES. WHB TO BE BRACKETED, NO PEDESTAL. WASTE PIPES TO BERECESSED. LEVER TAPS.

· 350 LITRE CAPACITY IN ROOF SPACE. PROVIDE EXPANSION TANK OF APPROXIMATELY45 LITRE CAPACITY. EACH TANK SHOULD BE PROVIDED WITH APPROPRIATE COVERAND SUPPORTED IN ACCORDANCE WITH GUIDELINES AS SET OUT IN THE BUILDINGREGULATIONS. WALKWAY TO BE LAID IN ATTIC FROM TRAP DOOR TO WATER TANK.LIGHT TO BE FITTED IN ATTIC.

· ALL SANITARY FITTING AND APPLIANCES TO HAVE FLEXIBLE PENNYVALVE FEEDS.· FIT 'COMBIMATE' WATER SOFTENER TO ALL HOUSES.· FIT 'MAGNACLEAN PROFESSIONAL' FILTER SYSTEM.· GULLY TO BE INSTALLED UNDERNEATH HEAT PUMP SYSTEM TO COLLECT WATER

EXTRACT FROM SYSTEM. GULLY TO BE LINKED TO FOUL WATER DRAINAGE SYSTEM.PVC DROP TO BE INSTALLED FROM UNIT TO GULLY UNDERNEATH TO ALLOW FORCONDENSATION RUNOFF

· 50mm (min) DRAIN ADJACENT TO THE WATER TANK UNIT OF THE HEAT PUMP -PLUMPED TO THE OUTSIDE TO ALLOW FOR OVERFLOW.

18. ELECTRICAL· BATHROOM & EXTERNAL LIGHTS TO HAVE LED 12 WATT COOL WHITE BULBS FITTED.· ALL SMOKE/HEAT DETECTORS TO BE LINKED.· ALL ELECTRICAL WORK TO BE TO CURRENT RECI STANDARDS· NO WALL SOCKETS ARE TO BE BACK TO BACK ON PARTY WALL· ALL SMOKE / HEAT / C02 DETECTORS TO BE WIRED BACK TO INDICATOR PANEL UNIT,

LOCATED BESIDE FUSE BOARD· SHOWER INSTALLATIONS TO HAVE ESB CABLE TAILS FROM METER TO BOARD TO BE 16

SQUARE, AND CABLE FROM BOARD TO SHOWER MUST BE 10 SQUARE. BATHROOMLIGHT TO BE ON AN RCD.

19. AIR TIGHTNESS TESTCONTRACTOR IS TO INCLUDE FOR CARRYING OUT AN AIR TIGHTNESS TEST.

20. BUILDING ENERGY RATING (BER) CERTIFICATECONTRACTOR IS TO PROVIDE BER CERTIFICATE ON COMPLETION OF CONSTRUCTION - MINIMUM ACCEPTABLE BER RATING IS A2

GENERAL SPECIFICATION1. FOUNDATIONS

· CONCRETE STRIP FOUNDATIONS TO ENGINEERS DETAILS AND SUBJECT TO SITECONDITIONS.

· FOUNDATIONS FOR EXTERNAL WALLS TO BE 1200mm (min.) X 300mm (min.) WITH A393 MESHBOTTOM. FOUNDATIONS FOR INTERNAL WALLS TO 1000mm (min.) X 300mm (min.) WITH A393MESH BOTTOM.

· FOUNDATIONS TO BE MADE ON UNDISTURBED GROUND AND ANY SOFT SPOTS TO BEREMOVED AND MADE GOOD WITH A LEAN MIX CONCRETE TO ENGINEERS APPROVAL.

· ALL CONCRETE FOR FOUNDATIONS TO 30N20 IN ACCORDANCE WITH BS8110.· MIN COVER TO A393 MESH TO BE 50MM

2. RISING WALLS· RISING WALL CONSTRUCTION TO BE 150MM EPS INSULATION OUTER LEAF,150MM 25N10 PLUS

STEEL REINFORCEMENT @2KG/M2 CORE AND 50MM EPS INSULATION INNER LEAF.

· 50mm CLEARANCE TO SURROUND SERVICE PIPES. FOR LARGE OPENINGS A LINTEL (NOTMETAL) SHOULD BE PROVIDED.

3. FLOORS· 150MM 35N10 POWERFLOATED CONCRETE FLOOR WITH A142 MESH.· KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR APPROVED), WITH VERTICAL STRIP

OF 30MM KOOLTHERM K3 (OR SIMILAR APPROVED) TO PERIMETER OF SLAB.· COMBINED RADON/DPM BARRIER 1200 GAUGE LAID TO MANUFACTURERS SPECIFICATION.

RADON BARRIER TO BE LAPPED AT LEAST 150MM AND SEALED AT ALL JOINTS AND ATD.P.C. ANY PUNCTURES IN BARRIER SHOULD BE PATCHED WITH THE SAME TYPE OFMEMBRANE, LAPPED AT LEAST 150MM AND SEALED BEYOND THE LIMITS OF THEPUNCTURE.

· 50MM SAND BLINDING.· 225MM COMPACTED CLAUSE 804 STONE COMPLIANT WITH S.R 21-2014 ANNEX E ON 400MM OF 75MM DIA CLEAN BROKEN STONE COMPLIANT WITH SR.21-2014 ANNEX E.· KINGSPAN KOOLTHERM K3 150MM BOARD (OR SIMILAR APPROVED), WITH VERTICAL STRIP

OF 30MM KOOLTHERM K3 (OR SIMILAR APPROVED) TO PERIMETER OF SLAB.

4. WALLS· 0.015W/M2K MAX. ICF (INSULATING CONCRETE FORMWORK) SYSTEM, WHICH CONSISTS OF

MODULAR INTERLOCKING EXPANDED POLYSTYRENE (EPS) BUILDING BLOCKS (STANDARDWHITE AND GREY) FOR PERMANENT FORMWORK FOR THE CONSTRUCTION OF IN-SITUCONCRETE WALLS. THE EXTERNAL WALLS, PARTY WALLS, FLOOR AND ROOF ARE TO BECONSTRUCTED IN THIS MANNER. THE GGBS RATIO OF ECO-FRIENDLY CEMENT USED IN THEPOUR MUST BE MINIMUM 70%. EACH OF THE BLOCKS IS LINKED TOGETHER WITH STEELTIES FOR STRENGTH. THE UNITS ARE TO BE ERECTED AS FORMWORK INTO WHICHVERTICAL AND HORIZONTAL REINFORCEMENT IS PLACED AND THEN FILLED WITHCONCRETE AND VIBRATED TO CREATE A MONOLITHIC CONCRETE WALL. THE POUREDWALL THEN RETAINS THE FORMWORK INSULATION FOR THE LIFE OF THE BUILDING. A LOWMAINTENANCE AND DURABLE EXTERNAL RENDER SYSTEM APPROVED BY NSAI AGRÉMENTFOR USE WITH ICF SYSTEMS IS TO BE APPLIED TO THE EXTERNAL POLYSTYRENEINSULATION OF THE ICF SYSTEM AS THE EXTERNAL FINISH. INTERNALLY, THEPLASTERBOARD IS FIXED DIRECTLY THROUGH THE EPS INTO THE CONCRETE CORE WITHPLASTIC INSULATED ANCHORS, OR ALTERNATIVELY SCREWED TO TIMBER BATTENS.

· ALL OPENINGS/HEADS/JAMBS ETC IN ACCORDANCE WITH MANUFACTURERS DETAILS.· CONCRETE CILLS ON PVC DPC TURNED UP AT BACK AND SIDES.· RENDER SYSTEM TO CONSIT OF A HIGH POLYMER BASE COAT (MIN 10MM), REINFORCING

MESH, SILICONE PRIMER AND SILICONE RENDER OR SIMILAR APPROVED FINISH.

5. ROOF· MAIN STRUCTURE. U VALUE MAX. 0.15W/M2K MAX. 250MM THICK INTERLOCKING

EXPANDED POLYSTYRENE (EPS) PANELS COMPLETE WITH INTEGRATED STEEL C-SECTINS.NAIL EVERY SECOND ROW OF ROOF TILES, AND ALL PERIMETER TILES.

· SELECTED CONCRETE ROOF TILES ON 44MM X 35MM TREATED BATTENS ON TYVECBREATHER MEMBRANE OEA ON 50MM X 50MM TREATED VERTICAL BATTENS FIXED TO250MM THICK THERMOHOUSE (OR SIMILAR APPROVED) INSULATED ROOF PANEL. ANYROOF TIMBERS TO BE PRESSURE TREATED INCL. FASCIA, SOFFIT, BARGE AND GABLELADDER TIMBERS.INCLUDE FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTINGFILLETS, RIDGE BOARDS ETC.PROVIDE ADEQUATE BRACING TO ROOF.

· INCLUDE FOR ALL STEEL MEMBERS AND BEARING PADS TO SUPPORT ROOF STRUCTURE.· INCLUDE FOR ALL NECESSARY PURLINS, HIPS, BEARERS, TILTING FILLETS, RIDGE BOARDS

ETC.· CONNECT ROOF STRUCTURE TO WALL PLATES USING PROPRIETARY TRUSS CLIPS IN

ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS.· EAVE VENTILATORS TO BE FITTED. ROOF VENT TILE TO BE FITTED AT RIDGE LEVEL AS PER

MANUFACTURES SPEC & DETAILS· PATINATION OIL FINISH TO ALL CODE 5 LEAD, TO MANUFACTURES SPECIFICATION AND

DETAIL.· DRY VERGE SYSTEM. EASY TRIM VERGE U COMPLETE WITH RIDGE CAPS, STARTER CAPS

AND END CAPS.

6. FASCIA, SOFFIT AND DOWNPIPES· ALUMINIUM FASCIA AND SOFFIT, 10MM CONTINUOUS VENT GAP BETWEEN FASCIA AND

SOFFIT (250MM OVERHANG).· 125MM SEAMLESS ALUMINIUM GUTTERS WITH 75MM X 50MM PVC DOWN PIPES.

7. INTERNAL DOORS· DOOR FRAMES TO BE DEAL.· FINISH SIZE TO BE EX 150MM X 50MM REBATED WITH 75MM X 20MM SPLAYED

ARCHITRAVES STANDARD TO FLUSH DOORS.· SOLID PLY VENEER FLUSH DOORS THROUGHOUT· LOCKS AND HANDLES TO BE BRASS SONNATO BW450PB.· 3 STEEL BUTT HINGES PER DOOR· 22MM WHITE/RED DEAL SADDLE BOARDS, VARNISHED.· DOOR STOPS TO BE FITTED TO ALL DOORS

8. D.P.C.· DPC CAVITY TRAY OVER ALL OPES· DPC TO BE USED UNDER WALL PLATE· DPC OVER OPES 160MM X 65MM EXTERNAL

9. OPES· ROW OF MASONARY MESH REINFORCEMENT FOR FULL LENGTH OF FRONT & BACK WALL

ABOVE LINTELS

10. WINDOWS & DOORS· PVC WINDOW FRAMES. EXTERNAL GLAZING THROUGHOUT TO BE OF A PROPRIETARY

TRIPLE GLAZED SUPERIOR QUALITY THERMALLY BROKEN GLAZING SYSTEM DESIGNED,BUILT AND INSTALLED TO LATEST RELEVANT EUROPEAN STANDARDS, CODES OFPRACTICE, AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTSAND RECOMMENDATIONS. MAXIMUM WHOLE FRAME U VALUE OF 0.7W/M²K AND AG-FACTOR OF 50% WILL BE REQUIRED FOR ALL WINDOWS AND EXTERNAL DOORS. ALLGLAZING MUST BE INTERNALLY BEADED/SECURED. EXTERNAL DOORS MUST BE IMPACTRESISTANT TIMBER HALL DOORS TO EN 1627, WITH LEVEL ACCESS THRESHOLD, & 3-POINTLOCKING SYSTEM. A MANUFACTURER'S THERMAL PERFORMANCE CERTIFICATE WILL BEREQUIRED FOR EACH WINDOW TYPE IN EACH HOUSE TYPE THROUGHOUT THEDEVELOPMENT FOR INCLUSION WITH THE BCAR INFORMATION AND CERTIFICATIONPROCESS.

· COMPOSITE FRONT DOOR AND THERMALLY BROKEN ALUMINUM BACK DOOR.· SAMPLE OF DOOR & WINDOW TO BE PROVIDED PRIOR TO ORDERING.· ALL BEDROOM WINDOWS TO HAVE MIN. OPE OF 850X500MM, ( IN COMPLIANCE WITH

CURRENT BUILDING REGS) TO ALLOW ADEQUATE MEANS OF ESCAPE. CHILD SAFETYRESTRICTORS TO BE FITTED TO BEDROOM WINDOWS.NON LOCKABLE HANDLES TO BEFITTED.

11. THERMAL BRIDGING· ALL INTERNAL PLASTERBOARD/PLASTER FINISHES TO GO DOWN TO FLOOR LEVEL.· ALL ELECTRICAL CONDUIT IN ATTIC SPACE TO BE SEALED.· AFTER FITTING OF WINDOWS & DOORS ALL GAPS TO BE SEALED BEFORE PLASTERING· ATTIC HATCH TRAP DOOR TO BE FITTED WITH LATCH AND DRAFT EXCLUDER STRIPS.· ALL PIPE AND SERVICE PENETRATIONS OF BUILDING ENVELOPE TO BE SEALED· THERMAL BRIDGING & ABC DETAILS TO COMPLY WITH 2007 BUILDING REGULATIONS. REFER TO THE DOCUMENT ' LIMITING AIR

INFILTRATION - ACCEPTABLE CONSTRUCTION DETAILS'· GLAZING TO BATHROOM TO BE OBSCURED· PRECAST CONCRETE CILLS THROUGHOUT WITH DPC TO SIDES, BACK & UNDERNEATH TO BE

USED THROUGHOUT.· 19MM BULLNOSE WHITE DEAL WINDOW BOARDS, PAINTED.· WINDOW BOARDS IN KITCHEN AND BATHROOM TO BE TILED.· DOORS & WINDOWS TO INCLUDE ALL NECESSARY IRONMONGERY. RECEIVER TYPE ON

EXTERNAL DOORS TO BE OF THE HOOKED TYPE. 5 POINT LOCKING SYSTEM.· FRONT DOOR TO HAVE THRESHOLD HEIGHT OF 15mm, WITH EXPOSED EDGES CHAMFERED.

TV

KEY TO ELECTRICAL SYMBOLS

T

8

T

NOTE 1:

INCLUDE FOR ALL NECESSARY BUILDERS WORK AND

ATTENDANCES FOR MECH. & ELEC. INSTALLATIONS.

ALL CHASINGS TO BE MACHINE CUT.

APPROVED SPECILIST CONTRCACTOR

LOCATIONS OF FIRE STOPPING - WORKS BY

SERVICES LEGEND

FOUL WATER AJ AND PIPEWORK

SURFACE WATER AJ AND PIPEWORK

SOIL VENT PIPE

nZED Compliant Specification:

· Space Heating / Cooling Demand

Not to exceed 15kWh annually or 10W (Peak Demand) per m²· Air Infiltration :

AIr Tightness: Acceptable range of 0.6 - 1 air changes/hour @50 Pascals· U-Values:

Floor: U-Value: 0.012W/m2k. 150mm thick insulation with a thermal conductivity of

0.022W/mk. 30mm insulation strip to all edges of floor.

Walls: U-Value: 0.015W/m2k Max. ICF (Insulating Concrete Formwork) System, which

consists of modular interlocking expanded polystyrene (EPS) building blocks (standard

white and grey) for permanent formwork for the construction of in-situ concrete walls.

The external walls, party walls, floor and roof are to be constructed in this manner. The

GGBS ratio of eco-friendly cement used in the pour must be minimum 70%. Each of the

blocks is linked together with steel ties for strength. The units are to be erected as

formwork into which vertical and horizontal reinforcement is placed and then filled with

concrete and vibrated to create a monolithic concrete wall. The poured wall then

retains the formwork insulation for the life of the building. A low maintenance and

durable external render system approved by NSAI Agrément for use with ICF

systems is to be applied to the external polystyrene insulation of the ICF system as the

external finish. Internally, the plasterboard is fixed directly through the EPS into the

concrete core with plastic insulated anchors, or alternatively screwed to timber battens.

Roof: U-Value: 0.15W/m2k Max. 250MM thick Interlocking expanded polystyrene (EPS)

panels complete with integrated steel C-Sectins.

Windows/ Doors: U-Value: External glazing throughout must be of a proprietary triple

glazed superior quality thermally broken glazing system designed, built and installed to

latest relevant European standards, Codes of Practice, and installed in accordance

with the Manufacturers requirements and recommendations. Maximum whole frame U

value of 0.7W/m²K and a G-Factor of 50% will be required for all windows and external

doors. All glazing must be internally beaded/secured. External doors must be impact

resistant timber hall doors to EN 1627, with level access threshold, & 3-point locking

system. A Manufacturer's Thermal Performance Certificate will be required for each

window type in each house type throughout the development for inclusion with the

BCAR information and Certification process.

· PV Panels:

2 Bed Semi (single storey): 2kWp Solar Photovoltaic system as per Spec Attached.

· Attic Access:

Attic access hatch is to be draught stripped

· Thermal Bridging:

0.08 x total exposed area (W/m2K) - refer to Appendix D in Part L 2011 Building

regulations for details

· Air Tightness:

All windows and doors are to be sealed with the appropriate air tightness tape and

membrane. Specialist Contractor to be appointed as required to carried out work

· Heating/Cooling/DHW/Ventilation System:

All in One" combi system which offers mechanical heat recovery ventilation system, air

space heating, Domestic Hot Water and Cooling(where required) in one indoor unit. The

MVHR element is a double stage process made to control the supply air intake

temperature up to 34 C via heat recovery and ensures DHW Production through a 180l

5mm polyurethane foam-insulated, 2-layer glass enameled hot water tank w/1.5 kw

immersion as backup. The combi system uses energy from exhaust air to first covers

ventilation losses with passive heat exchanger, and then it produces DHW and space

heating with the integrated Heat Pump. This is achieved using a 500W Compressor,

therefore using a small amount of energy. The heat pump has a reversible cooling

circuit, which means that, in the summer, the unit can cool the supply air by up to 10 °C.

Due to the low air exchange, the cooling does not function as an air conditioning

system. On cooling, the supply air is dehumidified, which gives a more pleasant indoor

climate than is possible with an ordinary ventilation unit without a heat pump.

The combi system mechanical ventilation heat recovery system will supply a large

portion of the required heat demand of the respective homes by circulating air which

has been fed through a heat exchanger. However, to supplement this system in times

of higher heating demand / colder weather, an electric radiant panel system is to be

supplied and installed. It is proposed to implement a 3 x 600W Radiant Panel system

with 1 panel installed in the Living/Dining Area and 1 panel in each of the bedrooms.

RADIANT HEAT BACKUP

The combi system mechanical ventilation heat recovery system will supply a large

portion of the required heat demand of the respective homes by circulating air which

has been fed through a heat exchanger. However, to supplement this system in times

of higher heating demand / colder weather, an electric radiant panel system is to be

supplied and installed.

It is proposed to implement a 3 x 600W Radiant Panel system with 1 panel installed in

the Living/Dining Area and 1 panel in each of the bedrooms. Suitable controls should be

integrated with the system to ensure it is operated efficiently and effectively. The sizing

and quantities of the panels can be finalized based on supplier recommendations but 3

x 600W in a home of such size is a good practice ratio. Consideration must be given to

the anticipated high thermal performance of the home and that limited heating will be

required. The radiant panels can be wall-mounted, or ceiling mounted depending on the

site layout/occupancy. To maximize space, thermal performance, aesthetics and negate

safety concerns, it is proposed that the Radiant Panels are ceiling mounted.

· Light Fittings:

100% Light bulbs are to be Low Energy Bulbs

· Draught Strips to Ext Windows & Doors:

All external windows and doors are to arrive to site with their draught stripping intact

and installed according to Manufactures specification and details

· Ventilation:

A Mechanical Ventilation Heat Recovery is to be installed. The MVHR is to provide

fresh filtered air into the building whilst retaining most of the energy that has already

been used in heating the building. The heat recovery ventilation system is to be properly

fitted to provide a constant supply of fresh filtered air, maintaining the air quality whilst

being practically imperceptible. The MVHR system is to operate by extracting the air

from the polluted sources e.g. kitchen, bathroom, toilets and utility rooms and supplying

air to the 'living' rooms e.g. bedrooms, living rooms, studies etc. The extracted air is

taken through a central heat exchanger and the heat recovered into the supply air.

SPACE PROVISION CALCULATION.DWELLING TYPE: 2 BED/3 PERSON SINGLE STOREY.

TARGET GROSSFLOOR AREA (m2)

MINIMUM-MAINLIVING ROOM (m2)

AGGREGATELIVING AREA (m2)

AGGREGATEBEDROOM AREA (m2)

60 13 28 20

STORAGE (m2)

3

65 13.2 28.2 21.35 3

PROPOSED GROSSFLOOR AREA (m2)

PROPOSED MAINLIVING ROOM (m2)

PROPOSEDAGGREGATELIVING AREA (m2)

PROPOSEDAGGREGATEBEDROOM AREA (m2)

PROPOSEDSTORAGE (m2)

General Specification

Max Permitted U-Values

Building Envelope Specification

Ventilation System Specification.

Heating/DHW/Vent/Cooling System

Specification.

Solar PV Performance

Specification

WEST ELEVATION Scale 1:100

EXPANSION JOINT.

LEVEL AREA OF 1.2M X 1.2M TO BE

PROVIDED AT FRONT ENTRANCE. RAMP NO

GREATER THAN 1:20 TO ACCESS LEVEL

AREA.

NAPPED & PAINTED

FINISH TO PORCH.

5120

2230

750

2100

750

2100

EXTERNAL RENDER SYSTEM

ON EXTERNAL INSULATION.

CONCRETE TILE ROOF.

DWELLING PLANELEVATIONS & SECTION.(2 BED SEMI-DETACHED DWELLING)

1. This drawing is the property of Carlow County Council, it is a confidential document and must not be copied, used, or its content divulged without prior written consent.2. DO NOT SCALE, use figured dimensions only, if in doubt ask.

NOTES

As Shown

R.S.

Project:

Title:

Drawn by:

Checked by:

Approved by:

Scale:

Date:

L.S. Rev:

No. Date Amendment / IssueChk.Drn.

A

Job No:

Drw Loc:

Drg. No:

App.

A FOR REVIEW

02/05/2019

RS.12/02/2020

LSL.S.

CARLOW COUNTY COUNCILHOUSING DEPARTMENT

Director Of Services: Michael BrennanTullow Civic Offices, Inner Relief Road, Tullow, Co. Carlow

Phone: (059)9136296 Fax: (059)9152156Email: [email protected]

Carlow Local Authorities, A CPD Accredited Company

Includes Ordnance Survey Ireland data reproduced under OsiLicence Number 2010/21 CCMA Carlow County Council.Unauthorised reproduction infringes Ordnance Survey

Ireland and Government of Ireland Copyright© Ordnance Survey Ireland 2015

L.S.

DWELLING PLAN, ELEVATIONS & SECTION. i-107

CONSTRUCTION OF 4 No.HOUSES AT ST MARYS COURT,

CO. CARLOW.

FOR REVIEW

ON 12.02.2020

AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
GY
AutoCAD SHX Text
TRAP DOOR - INCREASE TRUSS SPACE TO 550mm OVER HATCH ONLY
AutoCAD SHX Text
UNIT FOR BUILT IN FRIDGE / FREEZER
AutoCAD SHX Text
SINK UNIT
AutoCAD SHX Text
VOID FOR COOKER UNIT, WITH INTERGRATED HOOD OVERHEAD
AutoCAD SHX Text
DRAWER UNIT
AutoCAD SHX Text
CORNER UNIT
AutoCAD SHX Text
OVERHEAD UNITS
AutoCAD SHX Text
VOID & PLUMB FOR WASHER / DRYER VENT TO OUTSIDE
AutoCAD SHX Text
ALLOW FOR ISOLATOR SWITCH
AutoCAD SHX Text
SEPARATE HOT & COLD LEVER TAPS TO BE INSTALLED
AutoCAD SHX Text
ALL EXPOSED PIPES TO BE BOXED IN WITH PAINTED REMOVABLE PLYBOARD SHEETING
AutoCAD SHX Text
STORAGE TALL UNIT
AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
O/H UNITS
AutoCAD SHX Text
1500mm Dia Turning Circle
AutoCAD SHX Text
Telecom/Phone Cable Draw Box
AutoCAD SHX Text
ESB Meter Box
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SVP
AutoCAD SHX Text
GY
AutoCAD SHX Text
GY
AutoCAD SHX Text
LEVER TYPE TAPS TO BE INSTALLED
AutoCAD SHX Text
A
AutoCAD SHX Text
WALL MOUNTED HEAT PUMP OUTDOOR UNIT WITH DRAIN DOWN TO GULLY.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
A
AutoCAD SHX Text
GY
AutoCAD SHX Text
WALL MOUNTED HEAT PUMP OUTDOOR UNIT WITH DRAIN DOWN TO GULLY.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SPECIAL PRECAST CONCRETE DRAINAGE CHANNEL UNIT (AT ALL DOORS) TO BE INSTALLED & CONNECTED TO SURFACE WATER SYSTEM
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
GY
AutoCAD SHX Text
TRAP DOOR - INCREASE TRUSS SPACE TO 550mm OVER HATCH ONLY
AutoCAD SHX Text
UNIT FOR BUILT IN FRIDGE / FREEZER
AutoCAD SHX Text
SINK UNIT
AutoCAD SHX Text
VOID FOR COOKER UNIT, WITH INTERGRATED HOOD OVERHEAD
AutoCAD SHX Text
DRAWER UNIT
AutoCAD SHX Text
CORNER UNIT
AutoCAD SHX Text
OVERHEAD UNITS
AutoCAD SHX Text
VOID & PLUMB FOR WASHER / DRYER VENT TO OUTSIDE
AutoCAD SHX Text
ALLOW FOR ISOLATOR SWITCH
AutoCAD SHX Text
SEPARATE HOT & COLD LEVER TAPS TO BE INSTALLED
AutoCAD SHX Text
ALL EXPOSED PIPES TO BE BOXED IN WITH PAINTED REMOVABLE PLYBOARD SHEETING
AutoCAD SHX Text
STORAGE TALL UNIT
AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
O/H UNITS
AutoCAD SHX Text
1500mm Dia Turning Circle
AutoCAD SHX Text
Telecom/Phone Cable Draw Box
AutoCAD SHX Text
ESB Meter Box
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SVP
AutoCAD SHX Text
GY
AutoCAD SHX Text
GY
AutoCAD SHX Text
LEVER TYPE TAPS TO BE INSTALLED
AutoCAD SHX Text
A
AutoCAD SHX Text
Aj
AutoCAD SHX Text
A
AutoCAD SHX Text
GY
AutoCAD SHX Text
WALL MOUNTED HEAT PUMP OUTDOOR UNIT WITH DRAIN DOWN TO GULLY.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SPECIAL PRECAST CONCRETE DRAINAGE CHANNEL UNIT (AT ALL DOORS) TO BE INSTALLED & CONNECTED TO SURFACE WATER SYSTEM
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
RWP & BIGT.
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SOCKETS TO PARTY WALL TO BE FLUSH FIT, WITH NO CHASING. SEE TGD E DIAGRAMS 12 & 13. NO DOUBLE COURSING ON PARTY WALL. 75mm CAVITY.
AutoCAD SHX Text
FITTED WARDROBE WITH HANGING RAIL, AND SHELVED SECTION. WARDROBE TO EXTEND TO CEILING, WITH SHELVES AND SEPARATE DOORS OVER HANGING SECTION
AutoCAD SHX Text
1500mm Dia Turning Circle
AutoCAD SHX Text
`EASA` "THE ACCESS TRAY" 1000MM X 1000MM MIN LEVEL ACCESS SHOWER TRAY, WITH CLASSY SEAL WHERE TRAY MEETS WALL, GRADIENT TO DRAINAGE DOES NOT EXCEED 1:40 SLOPE. NEW SHOWER UNIT, WHICH IS TO BE A THERMOSTATICALLY CONTROLLED SHOWER WITH A SAFE ANTI-SCALD TEMPERATURE OF 41 DEGREES.(OFF TANK, NOT MAINS) A 2M FLEXIBLE HOSE IS TO BE PROVIDED. WEIGHTED SHOWER CURTAINS & HALF HEIGHT EASA EVOLUTION PORTABLE DOORS WITH CHROME FINISH AND POLYCARBONATE DOORS. FLOOR TO BE TILED WITH NON-SLIP TILES. WHB TO BE BRACKETED, NO PEDESTAL. WASTE PIPES TO BE RECESSED. LEVER TAPS.
AutoCAD SHX Text
MINIMUM DOOR OPENING WIDTH TO BE 800mm.
AutoCAD SHX Text
PATH TO SURROUND HOUSE, MIN. 100mm THICK CONC. ON BLINDED HARDCORE MIN. 150mm
AutoCAD SHX Text
ALL INTERNAL DOORS TO HAVE MIN. 775MM MINIMUM CLEAR OPENING WIDTH.
AutoCAD SHX Text
R11 TILES TO FLOOR. SKIRTING TILE AND TRIM.TILE WALLS AROUND SHOWER TO CEILING.
AutoCAD SHX Text
ICF PARTY WALL WITH REINFORCED 200MM CONCRETE CORE.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
Radiant Panel.
AutoCAD SHX Text
LIGHTING BATTEN
AutoCAD SHX Text
DOUBLE SOCKET-WORKTOP LEVEL
AutoCAD SHX Text
COOKER SWITCH
AutoCAD SHX Text
1 GANG LIGHT SWITCH
AutoCAD SHX Text
MECHANICAL VENTILATION UNIT
AutoCAD SHX Text
DUAL GROUP IMMERSION HEATER
AutoCAD SHX Text
SMOKE ALARM (Ei 2110 MULTI-SENSOR)
AutoCAD SHX Text
CONSUMER UNIT WITH ELCB
AutoCAD SHX Text
TELEPHONE POINT
AutoCAD SHX Text
TV AERIAL SOCKET
AutoCAD SHX Text
AV
AutoCAD SHX Text
M
AutoCAD SHX Text
HEAT DETECTOR (Ei 164 RC)
AutoCAD SHX Text
2 GANG LIGHT SWITCH
AutoCAD SHX Text
EXTRACT FAN SOCKET
AutoCAD SHX Text
WALL MOUNTED HEATING CONTROL
AutoCAD SHX Text
DOOR BELL
AutoCAD SHX Text
DOOR BELL PUSH
AutoCAD SHX Text
STRIP LIGHT SHAVER SOCKET
AutoCAD SHX Text
DOUBLE SOCKET
AutoCAD SHX Text
SINGLE SOCKET-WORKTOP LEVEL
AutoCAD SHX Text
EXTERNAL LIGHT
AutoCAD SHX Text
FRIDGE SWITCH
AutoCAD SHX Text
SMOKE ALARM (Ei 166 RC OPTICAL)
AutoCAD SHX Text
SINGLE SOCKET
AutoCAD SHX Text
PENDANT LIGHT
AutoCAD SHX Text
FUSEBOARD
AutoCAD SHX Text
Aj
AutoCAD SHX Text
Aj
AutoCAD SHX Text
SVP
AutoCAD SHX Text
RADIANT PANEL
Recommended