Part No: GJD012 GJD SOLITAIRE EXPANSION UNIT
INSTRUCTIONS
THE SOLITARE EXPANSION UNIT WORKS IN CONJUNCTION WITH THE SOLITAIRE
TOUCH CONTROLS AND GJD PASSIVE INFRA RED DETECTORS. THE MODULAR DESIGN
ENABLES THE EXPANSION UNIT TO BE CONVENIENTLY INSTALLED WITHIN EASY
ACCESS TO A MAINS SUPPLY, FOR EXAMPLE IN A LOFT OR A GARAGE. THE LOW
VOLTAGE CABLE LINK ALLOWS THE SOLITAIRE TOUCH CONTROL/S AND EXPANSION
UNITS TO BE POSITIONED ANYWHERE UP TO A DISTANCE OF 200 METRES APART.
SOLITAIRE EXPANSION UNIT SPECIFICATIONS
MAINS SUPPLY: 230Vac 50Hz via ELCB/M CB - unit fused at 13A
LIGHTING
OUTPUTS:
Each expansion unit switches two channels each up to 1500W of
resistive load or 1000 Watts of inductive load. The inductive load may
require a “snubber” (suppressor) to manage the lamp discharge
current.
PROVIDES: Each Expansion Unit provides: 12VDC at 120mA for any of the
following :
30mA – 2 Zone Solitaire Touch Control
50mA – 4 Zone Solitaire Touch Control
6mA – Opal XL External PIR
10mA – Elite External PIR
35mA – RFX-3 Receiver for Opal RFX wireless PIR
50mA – Additional devices for auxiliary output (e.g. Piezo sounder)
‘T’ OUTPUT: 5mA + timed signal. Suitable for driving base of NPN transistor.
CABLE GUIDE: Up to 200 meters – 7/0.2mm – 4 to 8 core for the GJD detectors
Up to 400 meters – 16/02mm – 4 to 8 core for the GJD detectors
Up to 200 meters – 7/0.2mm – 6 core screened to Touch Controls
(limitation of 200 metres from first Touch Control to last Expansion
Unit)
1.5mm twin & earth for mains cable
OPTIONS: Up to ten Solitaire Expansion Units can be added to a system for
additional switching capacity or 12 volt power.
OPERATING
TEMPERATURE:
-10 TO + 50 Centigrade
WEIGHT: 425 grams
DIMENSIONS: 146 x 87 x 48 mm
MOUNTING: Indoor use only.
Mount in a clean dry location on a secure flat surface.
Class 2 – Independently Mounted Control