GMPS Transductor Upgrades And Realtime B Field Measurement for Reference Magnet. Kent Triplett, Xiaolong Zhang. Main Objectives. Back up present system. Improve the GMPS stability and accuracy. Improve the B-dot stability and accuracy. Methods: Commercial Current Transformer Upgrade - PowerPoint PPT Presentation
Popular Tags:
20
GMPS Transductor Upgrades And Realtime B Field Measurement for Reference Magnet Kent Triplett, Xiaolong Zhang
Transcript
Page 1: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

GMPS Transductor UpgradesAnd Realtime B Field Measurement for

Reference Magnet

Kent Triplett, Xiaolong Zhang

Page 2: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Main Objectives

• Back up present system.• Improve the GMPS stability and accuracy.• Improve the B-dot stability and accuracy.• Methods:

Commercial Current Transformer UpgradeHall Probe Realtime B field measurement system

Page 3: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Transducer Original Designing

• The transducer in the in booster reference magnet measures the excitation current to the gradient magnets and thus regulate the GMPS system for the B:Imax and B:Imin.

• The original designing was a current transformer of 1200A with a output of 1245A/10V.

• It’s essential to Booster operation.

Page 4: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet
Page 5: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet
Page 6: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Evolution of Current Transducer

• The transducer system was upgraded a few times to present of water cooled 7500A transductor and relatively new electronics of 7500A/43V.

• The resolution and accuracy of the system is unknown.

• There might be 720Hz noise signal present. (“In order to reduce the transmission line mode excitation, the power supply have been designed as 12-phase supplies with a basic ripple frequency of 720Hz” TM-405)

Page 7: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Proposed Upgrades

• Since it’s critical for Booster operation, and it looks like we don’t have the spare, the backup or upgrade of the system is needed.

• There are a few commercial current transformer readily available with modern electronics from Hitec, LEM/Danfysik and ZES .

• Their specification (0 - 50KHz): Accuracy: < 3 ppm Output noise: < 6 ppm

• Advantage of the upgrade: Improve the accuracy of the GMPS current monitoring. Better for the feedback/feedforward system.

Page 8: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Specifications - ITP Current Transducers

Electrical

Model Symbol ITP 2000-SPR ITP 2000-S/SP1

ITP 2000-SBPR Units

Former Danfysik Model STH-2000I STH-2000IHF STH-2000U

Polarity Bipolar

Secondary Nominal Current Isn ±1 ±2 - A

Nominal voltage output Max. output load current Max. output load cap.

Von

Io,max

Co,max- -

±1053

VmAnF

Ext. burden resistor max Ext. burden resistor min

Rb,max

Rb,min

1.50 - Ω

Ω

Transfer ratio (Ip/Is)N 2000 1000 - -

Transfer ratio (Ip/Vs)G - 200 A/V

Max nondestructive overload Min overload trip value

Ip,max

Ip,min5x

1.3x5x

1.3xIpn

Ipn

Offset - Initial - Drift vs. Temp. - Drift vs. Time

- <2<0.1<1

<2<0.6<1

ppmppm/°C

ppm/month

Transfer ratio - Deviation - Deviation vs. Temp. - Deviation vs. Time

- <4

<0.1<1

<50<2<2

ppmppm/°C

ppm/month

Linearity Deviation Linearity Deviation vs. Temp.

Xd

Xd,temp<2

<0.1<4-

ppmppm/°C

Output noise rms -<0.01<3.5<5.5

<0.01<3

<5.5

<0.15<5.5 <16

ppm,rmsppm,rmsppm,rms

Dynamic resp. slew rate Dynamic resp. delay time

dl/dttd

>20<1

TBDTBD

>20<1

A/µSµS

Bandwidth ±3dB f 0-50 0-300 0-50 kHz

Page 9: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Realtime B Field Monitoring

• By measuring the B field during the cycle, we’ll be able to measure the optics more accurately.

• It’ll give us another instrument for B-dot system backup.

• Give more data for booster modeling and beam dynamics studying.

• The available commercial product of Lakeshore 460 3-axial Gaussmeter will be a good option.

Page 10: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Specifications of Lakeshore 460

Product Price Total

Gaussmeter, 460, $5,975.00 $5,975.00

Two-axis probe: 8 in long $1,537.00 $1,537.00

Probe, metal transverse, 0.06 x 0.18 x 8 in

$598.00 $598.00

111

Page 11: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet
Page 12: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Backup Slides

Page 13: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Benefits of These Upgrades

• We could measure the real time main B field and gradient.

• Build a better GMPS feedback/feedforward system (might be 4 additional 20A current feedforward system).

• Improve the B-dot timing system to better synchronize the beam transfer and other beam diagnosing.

Page 14: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet
Page 15: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Pros:$5575/unit.Used in the labat beam line.

Cons:4-6 weeks delievery

Page 16: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

PSU1000HF: $2615 each. This requires +/- 15 V power supply. If connecting to one of our power analyzers, we have cables made to provide this supply.SAT2000: $7699.00 each. Includes transducer head, power supply and cabling up to 30m. Both are in stock in up to 10 pcs.

Page 17: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet
Page 18: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Lakeshore 455 Single Channel

Page 19: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet

Power Line Frequency Variation

At fermilab, D. Herrup using 60Hz±30 mHz forEstimation the need for cogging

From LeapSecond.com

Page 20: GMPS  Transductor  Upgrades And  Realtime  B Field Measurement for Reference Magnet